Home

Vapir NO2 Vaporizer Instructions User Manual PDF

image

Contents

1. FOR USAGE 1 Always pre grind your herbs it is important that you finely grind your herbs to allow heat to penetrate all surface areas for maximum benefit 2 Set the unit to your desired temperature Using the and buttons you can toggle through exact temperature settings in order to find the one you desire It does take a little practice to find the perfect temperature for your liking In the meantime here is a good guideline to follow if you are not getting enough flavor turn the temperature up If your herbs are burning then turn the temperature down 3 When you have set your desired temperature engage the heating element by pressing the Heat Button Red Button located beneath the LCD Temperature Display Once this button has been pressed a Red LED light will illuminate above the LCD Temperature Display indicating the heating process has begun 4 Now that the unit has reached the desired temperature the Red LED will change to a Green LED indicating the unit is fully heated and ready for usage Please note the temperature will change inside the unit causing the temperature to drop slightly and the Green LED will revert back to a Red LED indicating the unit is re heating to reach your desired temperature This is normal and will occur during usage Vapir recommends plugging your NO2 into a surge protector while using in AC mode BM DIRECTIONS FOR USAGE 5 Once the unit has reached the desired temperature and i
2. 0C a 1500 212F a 302F Salvia 1256 a 150C 257F a 3D2F Palmito 125C a 170 257F a 347F Tabaco 1256 a 150 257F a 302F MN GARANT A Vapir Modelo NO2 Garant a limitada de un a o Respondemos por nuestros productos y por nuestros clientes Vapir cubre su NO2 por todo un a o contra cualquier defecto de fabricaci n Debe registrar su garant a dentro de los primeros quince d as despu s que recibi el producto Para registrar su garant a visite www vapir com warranty La bater a no est cubierta dentro del a o de garant a todas las bater as tienen una garant a limitada de 180 dias BN DISCLAIMER Todos los vaporizadores Vapir est n destinados solo para uso legal Vapir no hace afirmaciones sobre los riesgos de salud asociados con el tabaquismo o la vaporizaci n La vaporizaci n no puede eliminar todos los riegos de salud asociados con el tabaquismo Si no est seguro acerca de los riesgos de salud asociados con el tabaquismo o la vaporizaci n por favor consulte a su m dico Vaporice bajo su propio riesgo Vapir Inc Tel fono 1 800 841 1022 NO2 es marca registrada propiedad de VapirTM y protegida por todas sitio Web www vapir com TM las leyes de derechos de autor tanto de los Estados Unidos como VAPI r E Mail customerservice vapir com internacionales El Vaporizador NO2 utiliza tecnolog a patentada protegida por la patente estadounidense No 6772756 amp 20090095287 IDENTIFIQUE LAS PA
3. ES VAPORIZATION TEMPERATURES FOR POPULAR HERBS Clove 125C to 150C 257F to 302F Dandelion 125C to 150C 257F to 302F Lavender 100C to 125C 212F to 257F Peppermint 100C to 150C 212F to 302F Sage 125C to 150C 257F to 302F Tobacco 125C to 150C 257F to 302F Saw Palmetto 125C to 175C 257F to 347F Cats Claw 150C to 175C 302F to 347F Damiana 150C to 175C 302F to 347F Garlic 170C to 185C 337F to 365F Ginger 170C to 185C 337F to 365F O warRANTY INFORMATION Vapir NO2 1 Year Limited Product Warranty We stand behind our products and our customers Vapir Covers your NO2 for 1 Full Year against any manufacturer defects You must register you warranty within the first 15 days of receipt of the item To register your warranty please go to www vapir com warranty Battery is not covered under the 1 year warranty all batteries have a 180 day limited warranty Y oiscLaimer All Vapir Vaporizers are intended for legal use only Vapir makes no claims about any health risks associated with smoking or vaporizing Vaporizing may not remove all health risks associated with smoking If you are unsure about any health risks associated with smoking or vaporizing please consult your doctor Vaporize at your own risk Vapir Inc Phone 1 800 841 1022 NO2 is a Trademarked name owned by Vapir and protected by all US TM Website www vapir com VA 12 i TM and International Copyright Laws The NO2 Vaporizer utilizes
4. Patented VA 2 r E Mail customerservice vapir com Technology protected by US Patent No 6772756 amp 20090095287 A IDENTIFYING THE PARTS Top Mouthpiece Top Mouthpiece opening unscrew to open LED Heat indicator light Digital Temperature Display Temperature Down Button Heat ON OFF Button amp C F Temperature Setting Set Actual Temperature Battery charge indicator Power ON OFF Button Temperature Up Button Battery Door PRE USAGE INSTRUCTIONS ADDITIONAL PARTS The NO2 comes with 1 Internal Re Chargeable Battery 1 Power Cord 3 Sets of Mesh Bowl 1 already installed 2 Bamboo Cleaning Sticks 1 Measuring Cup 1 Cleaning Brush 1 Tube Attachment and 1 X Tip Mouthpiece Prior to using the tube attachment make sure to soak it in warm water DO NOT USE BOILING WATER It is suggested that you use the tube attachment while vaporizing for a much better draw To install the tube simply push one end of the tube over the top of the unit until it is fully secure You can also use the mouthpiece in conjunction with the tube Installation of the mouthpiece is quite easy simply push the open end the larger opening over the open end of the tube until it is fully secure Included are 2 sets of mesh screens for usage when the first set becomes too dirty or worn out You can clean the mesh screens using the cleaning brush Changing Internal Mesh Screen Using the Bamboo Cleaning stick included
5. RTES INSTRUCCIONES PREVIAS AL USO PARTES ADICIONALES Previo a utilizar el tubo accesorio aseg rese de mojarlo en agua tibia NO USE AGUA HIRVIENDO Se sugiere que utilice dicho tubo mientras vaporiza para obtener un mejor resultado de absorci n Para instalar el tubo simplemente empuje un extremo del tubo sobre la parte de arriba de la unidad hasta que quede totalmente seguro Puede utilizar la punta X en combinaci n con el tubo La instalaci n es f cil Tapa Boquilla simplemente empuje la abertura m s grande sobre el extremo abierto del tubo hasta que est totalmente seguro Apertura de Tapa Boquilla Desenroscar para abrir Se incluyen tres juegos de pantallas de malla para que las pueda utilizar Un juego ya est instalado y hay dos juegos de pantallas adicionales para uso futuro cuando el primer juego est muy sucio o gastado Puede limpiar las Temperatura pantallas con el cepillo limpiador Ajustar Actual Luz indicadora de calor Cambiando las pantallas de malla internas Usando el palillo de bamb para limpiar incluido en la unidad Coloque el palillo dentro de Pantalla digital Indicador de la c mara de hierbas hale el fondo de la pantalla de malla y hale de temperatura carga de bater a hacia fuera la pantalla debe salir f cilmente Para instalar la nueva use el palillo de bamb y simplemente empuje la pantalla cil ndrica de Bot n para disminuir Bot n de apagado temperatura y encend
6. a Indicador de la carga de la bater a El modelo NO2 viene equipado con un indicador de carga ubicado en la esquina inferior derecha del indicador LCD Dicho indicador marcar cuanta carga tiene la bater a y parpadear para indicar que est cargando La bater a dura aproximadamente 45 60 minutos con una carga completa Las barras del indicador de la bater a podr an mostrar menos durante el uso esto es normal Memoria de la temperatura El modelo NO2 viene con memoria de temperatura Cada vez que lo encienda autom ticamente se colocar en la temperatura en que fue utilizada previamente J MECANISMO DE SEGURIDAD DE CALOR REPUESTOS Y ACCESORIOS REN Mecanismo de seguridad de calor Para detener el proceso de Adaptador de 12 voltios calentamiento presione el bot n de calor bot n rojo debajo del indicador de temperatura LCD Notar que la luz verde o roja que indica que el calentador est encendido se apaga Si la luz verde o roja todav a est Cargador externo de la bater a encendida quiere decir que el calentador no se ha apagado Adem s esta unidad tiene un mecanismo de seguridad de 20 minutos o Despu s de 20 minutos de uso continuo el elemento de calor se apagar Esla es ness Si todav a est usando la unidad cuando se inicie dicho mecanismo puede volver a colocar el calor inmediatamente para que el uso sea continuo Paquete de 10 pantallas de malla Paquete de 3 tubos Paquete de 10 boqui
7. charge your internal re chargeable battery 1 You can leave the battery inside the NO2 while it is plugged into an electrical wall outlet using the power adaptor If the NO2 is powered on while plugged into an electrical wall outlet even if the unit is being used the battery will automatically re charge In order for the battery to re charge the unit needs to be plugged in and the Power ON OFF switch needs to be in the ON position the heat does not need to be engaged 2 For optimal battery life automatic re charging only occurs when the battery charge is at 2 bars or less To over ride simply switch the unit OFF and then ON to begin re charging 3 The NO2 also has an optional external battery charging cord which is available for purchase Re Chargeable Battery Charge Indicator The NO2 comes outfitted with a battery charge indicator located at the lower right hand corner of the digital LCD Display This indicator will display how much charge the battery has remaining and will blink to indicate that it is recharging Battery lasts approximately 45 60 minutes on a full charge battery indicator bars may show less during actual usage this is normal Set Temperature Memory The NO2 also comes with a temperature memory every time you turn your NO2 on it will automatically be set to the temperature you had used during you last vapor session Changing Temperature from Fahrenheit to Celsius To change the temperature reading from Fahrenh
8. eit to Celsius or from Celsius to Fahrenheit simply hold down the heat button 2 5 seconds 6 A HEAT SAFETY MECHANISM REPLACEMENT PARTS AND ACCESSORIES Pri 12 Volt Adapter To stop the heating process press the Heat Button Red Button located beneath the LCD Temperature Display You will note that the Green Red LED light which indicates the heater is on will turn off indicating the heater has been turned off If the RED GREEN LED light is still on the heater is not turned off External Battery Charger Further this unit has a safety default setting of 20 minutes After 20 Cleaning Sticks minutes of continuous heating the heating element will automatically shut off If you are still using the unit when the 20 minute safety default heat setting is triggered you can re engage the heat immediately to continue usage 20 Pack of Mesh Screens 3 Pack of Tubes 10 Pack of X Tip Mouthpieces 5 Pack of Cleaning Brushes 5 Pack of Scoops Replacement parts for this unit can be purchased directly from our website www vapir com by calling 7 600 841 1022 7 8 TEMPERATURA DE VAPORIZACION PARA LAS HIERBAS MAS POPULARES U a de gato 1506 a 1750 302F a 347F Clavo de olor 125 a 150 257F a 302F Damiana 150C a 1750 302F a 347F Amarg n o diente de le n 125C a 1500 257F a 302F Ajo 1706 to esc 337F to 65F Jengibre 170C to 185C 337F to 3865F Lavanda 100C a 125C 212F a 297F Menta 10
9. ido malla dentro de la c mara de las hierbas hasta que llegue al fondo La pantalla debe descansar completamente nivelada en el fondo de la Bot n de apagado y Bot n para c mara de las hierbas encendido del calor aumentar la C F ajuste de temperatura temperatura Cambiando las pantallas de malla de la boquilla Quite la boquilla de la unidad dando vuelta suavemente en sentido contrario a las agujas del reloj Al dar vuelta a la boquilla ver el sujetador de la pantalla de malla Para quitarla simplemente encuentre la tira de tres l neas en cada lado del sujetador de la pantalla de malla Tome las tres l neas y gire en sentido contrario a las agujas del reloj para abrir Si el sujetador de las pantallas de malla es muy dif cil de quitar Usted puede utilizar cuidadosamente pinzas para hacerlo Ahora quite la Suera de lerere pantalla usada y coloque la nueva en su lugar Para ayudar con la instalaci n de la malla de la boquilla use la punta del NO2 cuando se quita de la unidad para presionar la pantalla en la forma correcta Finalmente vuelva a colocar el sujetador de la pantalla presionando y girando hasta que quede seguro en su lugar COMIENZO R PIDO 1 Triture sus hierbas 2 Encienda la unidad 3 Establezca la temperatura deseada aproximadamente 375 385F o 191 2000 4 Presione el bot n rojo para encender el calor 5 Quite la tapa coloque las hierbas aproximadamente a 3 4 de su capacidad
10. l de la bater a Carga Antes de usar el NO2 en el modo de bater a la bater a debe ser cargada por un total de 8 12 horas para obtener un ptimo rendimiento de la bater a La carga posterior de la bater a es solo de 4 6 horas Uso de la bater a recargable Despu s que la bater a ha sido adecuadamente recargada e instalada dentro de la unidad el uso es f cil Simplemente desconecte la unidad del adaptador de pared que est en la base de la unidad Cuando encienda la unidad el poder de la bater a operar la unidad y podr utilizarla de forma inal mbrica C mo se recarga la bater a El modelo NO2 viene con dos formas diferentes de recargar la bater a 1 Puede dejar la bater a dentro del modelo NO2 mientras se conecta a un enchufe con el adaptador de poder Si el modelo NO2 se enciende mientras est conectado a un enchufe aun si se est utilizando la unidad la bater a se recargar de modo autom tico Para que la bater a vuelva a cargar la unidad necesita estar enchufada y el interruptor de encendido y apagado debe estar en la posici n de ENCENDIDO El calor no necesita involucrarse 2 Para una vida optima de la bater a la recarga autom tica solo se produce cuando la carga de la bater a es de 2 barras o menos Para recargar simplemente apague la unidad y enci ndala para empezar a recargar 3 El NO2 tambi n tiene un cable opcional para la carga de la bater a externa el cual est disponible para su compr
11. llas de punta X Paquete de 5 cepillos de limpieza Paquete de 5 cucharitas medidoras YO Puede adquirir los repuestos para esta unidad directamente en nuestro sitio web www vapir com o llamando al 1 800 841 1022
12. o menos Coloque la tapa nuevamente ahora puede inhalar y disfrutar Para una mejor inhalaci n se sugiere usar el tubo incluido INSTRUCCIONES DETALLADAS DE USO 1 Siempre triture sus hierbas previamente Es importante que las triture finamente para permitir que el calor penetre en todas las reas de la superficie para m ximo beneficio 2 Coloque la unidad a la temperatura deseada Utilice los botones y Se puede ajustar la temperatura para que encuentre la que m s le convenga Toma cierta pr ctica encontrar la temperatura perfecta o a su gusto Mientras tanto a continuaci n aparece una gu a si sale humo baje la temperatura Si no se obtiene suficiente sabor suba la temperatura La temperatura recomendada de encendido es de 380 212 C 3 Una vez ha establecido la temperatura presione el Bot n de Calor ubicado debajo del indicador de temperatura LCD Una vez presionado dicho bot n se encender una luz roja sobre el indicador de temperatura LCD indicando que el proceso se ha iniciado 4 Ahora que la unidad ha alcanzado la temperatura deseada la luz roja cambiar a verde indicando que unidad ha calentado totalmente y est lista para usarse Por favor observe que la temperatura cambiar dentro de la unidad causando que baje ligeramente y la luz verde se torne roja otra vez indicando que la unidad se est recalentando hasta alcanzar la temperatura deseada Esto es normal y ocu
13. rrir mientras se use Vapir recomienda conectar el NO2 en un protector contra sobretensiones mientras lo use en modo AC A INSTRUCCIONES DETALLADAS DE USO 5 Una vez la unidad ha alcanzado la temperatura deseada y se ha precalentado completamente se puede quitar la tapa al girarla lentamente en direcci n de las agujas del reloj dejando ver la c mara de las hierbas Una vez que se ha quitado la tapa se pueden colocar las hierbas previamente trituradas dentro de la unidad asegur ndose que la c mara no est llena a m s de tres cuartos de su capacidad Si llena demasiado la c mara de las hierbas impedir el flujo de aire y al mismo tiempo que el calor penetre las hierbas y no se vaporicen totalmente 6 Inmediatamente despu s que las hierbas ha sido colocadas en la c mara puede volver a colocar la boquilla girando hasta que quede segura Una vez la tapa est colocada puede inhalar y disfrutar Para mejor funcionamiento aseg rese de limpiar la unidad despu s de cada uso Se puede limpiar la unidad con el cepillo limpia OPERACI N DE LA BATER A Y ESTABLECER LA MEMORIA DE LA TEMPERATURA Ubicaci n de la bater a recargable El modelo NO2 viene con una bater a recargable de ones de litio que puede ser ubicada f cilmente al abrir la puerta de la unidad de la base y deslizar la bater a hacia adentro o hacia fuera El modero NO2 funciona con o sin la bater a instalada en la unidad Uso Inicia
14. s fully pre heated you can remove the top by gently twisting counter clockwise exposing the herb chamber Once the top is removed you can insert your pre ground herbs into the unit making sure the herb chamber is no more than 3 4 full If you over fill the herb chamber you will impede the air flow which will prevent the heat from penetrating your herbs and thus prohibit full vaporization from occurring 6 Immediately after the herbs have been placed into the herb chamber you can re attach the mouthpiece by gently turning clockwise until it is securely attached Once the top is attached you can inhale and enjoy For optimal performance make sure to clean the unit after each usage BATTERY OPERATION AND SET TEMPERATURE MEMORY Locating Re Chargeable Battery Lithium lon Battery can be easily inserted or removed by opening the door at the base of the unit Initial Battery Usage Charging Prior to using the NO2 in Battery Mode the battery must be charged for a full 8 12 hours for optimal battery performance Subsequent charging of battery is only 4 6 hours Re Chargeable Battery Usage After the internal battery has been properly charged and installed into the unit unplug the unit from the wall adaptor located at the base of the unit When you power the unit on battery power will automatically take over and you can use your unit cordless Re Chargeable Battery Charging The NO2 comes with two different ways you can re
15. with the unit put the stick inside of the herb chamber and grab the bottom of the mesh screen and lifts out the screen should come out quite easily To install the new screen use the bamboo stick and simply push the screen inside the herb chamber until it reaches the bottom and is flush with the bottom of the herb chamber Changing Mouthpiece Mesh Screen Remove the top of the unit by gently turning it counter clockwise Turning the mouthpiece over you will see the mesh screen holder To remove the mesh screen simply locate the 3 lines on either side of the mesh screen holder Securely grab the 3 lines and turn counter clockwise to open If mesh screen holder is difficult to remove you can gently use pliers to do so Remove the old mesh screen and insert a new mesh screen To assist with installation of the mouthpiece mesh screen use the tip of the NO2 when removed from unit to depress the screen into the correct shape Now replace the mesh screen holder by pressing down and turning clockwise until secure 2 QUICKSTART GUIDE 1 Grind Your herbs 2 Turn the Unit On 3 Set Desired Temperature Not enough flavor Turn temperature up If herbs are burning Turn temperature down 4 Press Red Button to Engage Heat 5 When LED Turns Green Remove Top amp Insert Herbs approximately 3 4 full or less Replace top then inhale and enjoy For best draw it is suggested that you use the included tube DIRECTIONS

Download Pdf Manuals

image

Related Search

Related Contents

Sony PDW-F75 XDCAM HD Recorder/Player  Symantec AntiVirus Corporate Edition 10.0 (10362814)  User Manual - MSR Electronic  Stereo Headphones - CNET Content Solutions  Toshiba FT-8801A Cordless Telephone User Manual  取扱説明書 CY-ECR300    kit d`alimentation solaire  User Manual HW80-1479  Mode d`emploi Fumoir FT1 Le fumoir FT1 et tous les  

Copyright © All rights reserved.
Failed to retrieve file