Home
Human Vibration Analyzer - Type 4447
Contents
1. An increase in the number of hand arm and whole body injuries caused by vibration is the consequence of the use of modern appliances that are powered by external power sources Hand tools machinery and heavy vehicles cause vibration the harmfulness of which depends on its intensity and frequency content and the time of exposure Human Vibration Analyzer Type 4447 a portable system for acquisition measurement and evaluation of human vibration is designed to meet the requirements of those who wish to monitor and reduce the exposure of human operators to the harmful influences of such vibration USES AND FEATURES USES e Hand arm vibration measurements 1 to 1250Hz e Whole body vibration measurements 1 to 80 Hz e Low frequency whole body vibration measurements down to 0 4Hz e Linear mode 0 4 to 1250 Hz for calibration FEATURES e Compact stand alone instrument with an internal power source e Versatile graphics display for control of the instrument and analysis of results Tentative PRODUCT DATA Human Vibration Analyzer Type 4447 Briel amp Kj r 060152 Only four buttons to control the instrument s functions ideal for field work All the necessary data is displayed for instant assessment of exposure to vibration Very few cables only one cable connection to a transducer in basic setup USB connection to a computer for post processing and archiving Risk assessment following the good
2. practice guide for human vibration Briel amp Kj r lt Introduction Measurement Options Display This instrument has been designed for those working with human vibration and who require quick and reliable results Using Type 4447 measurements can be made easily as only the necessary parameters required by EU Directive 2002 44 EC are calculated The instrument was developed and designed on the basis of input from several groups concerned about human vibration Consultants working with measurements of and risk evaluations caused by exposure to occupational vibration Departments for occupational health Manufacturers of building machinery freight vehicles and other machinery causing vibration Manufacturers of anti vibration pads seats and personal protection equipment Manufacturers of all kinds of hand tools Educational institutions Medical institutions Type 4447 simultaneously measures and calculates the following parameters Three components of the running RMS vibration weighted or unweighted a ay Three components of the peak vibration weighted or unweighted a peaks Ay peak 4z peak The crest factor for each axis The frequency weighted hand arm vibration awx awy awz The frequency weighted whole body vibration awx awy awz The combined vibration on all 3 axes as a vector sum ay with implementation of the k factors for whole body MTVV Maximum Transient Vibration Value MSDV Motion Sickne
3. V the peak values for individual axes and the crest factor The crest factor indicates the impulsiveness of the vibration Instantaneous and equivalent results for the individual and combined axes are available while the measurement is in progress After the measurement has stopped additional parameters are available the calculated 1 4 and 8 hour exposure values Fig 1 the allowed time exposure and maximum rms values Before a new measurement is started the current results can be stored or you can choose to overwrite them Exposure m s2 Elapsed time The instrument has space for up to 750 measurements 00 10 15 in a non volatile memory A 1 O12 Stored results can be recalled to the display or sent over the USB interface to a PC for further processing A 4 0 4 A 8 OS Software is included with the instrument to enable the transfer of results to a PC and their manipulation For instance you can use the software to combine the results from different measurement points and give exposure limits for combined operations see Fig 2 File Edit _ Tools Help 3 cep Me ss Measurement mode A X ACY A Z A 8 j VDV X vDv Y VDV Z VDV M ts easuremen 0 00 0 00 0 00 0 00 0 00 Test results 0 51 0 66 0 66 8 56 8 74 7 33 874 S me Mark aoe 4 e sla Minute 0 5 10 15 20 25 30 35 40 45 50 55 The commonly used weighting curves for hand arm and whole body vibration are stored in the
4. instrument by default Other weighting curves can be added as required Multiple weighting filters can also be added to the instrument with an optional utility tool to meet the requirements of ISO 8041 or other relevant standards What is Included Human Vibration Measuring Kit Fig 3 Human Vibration Measuring Kit Handle Adaptor Handle Adaptor Human Vibration Measuring Kit Type 4447 includes the following items e Four channel Human Vibration Analyzer e Triaxial Accelerometer Type 4524 e Adaptors for hand arm and direct mounting of an accelerometer e Power supply and charger e Seatpad adaptor e USB connection cable e Software for the download and calculation of daily exposures for 1 4 and 8 hour periods e User manual e Power supply The following option is also available e Calibration Exciter Type 4294 Tentative Compliance with Standards CE mark indicates compliance with EMC Directive and Low Voltage Directive C Tick mark indicates compliance with the EMC requirements of Australia and New Zealand Safet EN IEC 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use y UL 61010 1 Standard for Safety Electrical measuring and test equipment EN IEC 61000 6 3 Generic emission standard for residential commercial and light industrial environments EMC Emission EN IEC 61000 6 4 Generic emission standard for industrial environments CISPR 22 Radi
5. o disturbance characteristics of information technology equipment Class B Limits FCC Rules Part 15 Complies with the limits for a Class B digital device EN IEC61000 6 1 Generic standards Immunity for residential commercial and light industrial environments EMC Immunity EN IEC 61000 6 2 Generic standards Immunity for industrial environments EN IEC 61326 Electrical equipment for measurement control and laboratory use EMC requirements Note The above is only guaranteed using accessories listed in this Product Data sheet Specifications Human Vibration Analyzer Type 4447 Type 4447 complies with the following National and International Standards e ISO 8041 2005 Technical specification e ISO 5349 2 2001 Hand arm e ISO 2631 1 1997 Whole body e EN 1032 2003 Mechanical vibration e EU Dir 2002 44 EC SUPPLIED ACCELEROMETER Type 4524 B 001 Sensitivity 10 mV g Frequency 0 5 Hz to 6 5 kHz DYNAMIC RANGE Type 4447 has one measuring range which covers the range of the supplied accelerometer Useful range is between 0 m s to approx 450 m s more than 80dB NOISE Noise Level lt 5mV or 80dB of full scale 7 Vp Depends on the high pass Filter DETECTOR Simultaneous measurement of peak and rms vibration value for each channel FREQUENCY WEIGHTING Filters for frequency weightings are calculated in time domain to conform ISO 8041 2005 including filters Wp Wg and W Other frequency c
6. ss Dose Value VDV Vibration Dose Value Evaluation of results with respect to daily exposure limits and action values for hand arm and whole body vibration az User friendly graphical interface for set up of measurements and readout of results Current measurement results expressed as running rms peak crest factor time averaged vibration sum peakmax MTVV MSDV VDV Readings in g m s ft s in s or dB Display of k factors Measurement status Stop Pause Run Elapsed time Battery status Colour input status indication Overload indication Open circuit and short circuit connection warning Voltage input Memory Only parameters required by EU Directive 2002 44 EC are enabled and displayed Tentative Description Fig 1 Calculated exposure values Fig 2 Calculated exposure values Tentative Type 4447 has four analog inputs and one USB digital I O The inputs are designed for use with tri axial or mono axial accelerometers and are equipped with selectable CCLD ICP power supplies The sensitivity of the input channels is designed to fit the typical transducers used in human vibration The inputs are equipped with the necessary W weighting curves for hand arm and whole body vibration measurement The processing power of the instrument is such that it can display all measurement parameters including the combined vector sum of all three axes with added k for whole body the vibration dose VD
7. urves can be added on request DISPLAY Sony Colour graphical display with the resolution of 124 x 124 pixels Tentative Basic information regarding the instrument status is shown through icons including battery indicator measurement status run pause stop input type U as direct or voltage input or OK as DeltaTron input Overload OVL Open OPN or short SHT and real time or elapsed time MEASURING PARAMETERS Measured parameters are selected according to the selected setup mode The following parameters are measured and calculated during measurement Time Averaged Weighted Acceleration Value TAWAV Maximum Transient Vibration MTVV Vibration Dose Value VDV Motion Sickness Vibration Dose MSDV running rms acceleration value Resolution 0 01 m s MEMORY 64kB or 750 measurements can be stored in non volatile memory USB INTERFACE Conforms to USB 2 0 Connector Mini B CLOCK Real time clock with calendar CALIBRATION Reference Vibration Value 10 m s Reference Fequency 159 4 Hz or 79 7 Hz Reference Electrical Level 100 mV Frequency 79 7 Hz BATTERY Rechargeable Li ion battery 3 7 V 2400 mA More than 3 5h continuous use at room temperature PHYSICAL DIMENSIONS Size 70 x 135 x 28mm 2 7 x 5 3 x 1 1 Weight 260g 9 2 oz battery included Ordering Information Type 4447 A Human Vibration Analyzer including Type 4447 B Type 4515 B 001 Triaxial DeltaTron Seat Pad Accelerometer
8. v com info bksv com Australia 61 2 9889 8888 Austria 43 1 865 74 00 Brazil 55 11 5188 8161 Canada 1 514 695 8225 China 86 10 680 29906 Czech Republic 420 26702 1100 Finland 358 9 521 300 France 33 16990 71 00 Germany 49 421 17 870 Hong Kong 852 2548 7486 Hungary 36 1215 8305 Ireland 353 1 807 4083 39 0257 68061 Japan 81 35715 1612 Netherlands 31 318 55 9290 Norway 47 6677 1155 PBI Portugal 351 21 41 69040 Republic of Korea 82 23473 0605 S r 2 Slovak Republic 421 25443 0701 Spain 34 91 659 0820 Sweden 46 33 225 622 Switzerland 41 44 880 7035 Taiwan 886 2 2502 7255 United Kingdom 44 14 38 739 000 USA 1 800 332 2040 Local representatives and service organisations worldwide Briel amp Kj r lt Rosendahls Bogtrykkeri 2006 07 BP 2147 11
9. with built in Type 4524 B 001 10 mV g TEDS with 3m integral cable to 4 pin LEMO Type 4294 AO 0694 D 012 3x10 32 UNF LEMO female adaptor 1 2m for OPTIONS Type naar and 4447 B Type 4294 AQ 0693 D 025 LEMO to 4 pin 1 4 28 connector cable 2 5m for yG_ogg4 p 012 Type 4447 A and 4447 B and the following accessories AO 0693 D 025 Hand Adaptor Handle Adaptor Human Vibration Analyzer including all components and accessories listed for Type 4447 A plus Calibration Exciter Calibration Exciter included in Type 4447 B 3 x10 32 UNF LEMO female adaptor 1 2m for Type 4447 A and 4447 B LEMO to 4 pin 1 4 28 connector cable 2 5m for Type 4447 A and 4447 B Cube Adaptor for direct fixation SERVICE PRODUCTS Basic software for data transfer utility organising measurement site and calculation USB standard A to USB mini B interface cable Universal Charger Traceable Calibration with certificate Extended Warranty 1 year Extended Warranty 3 years Screwdriver 1 Will be available ffom September 2006 TRADEMARKS ICP is a registered trademark of PCB Group Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and or other countries SONY is a registered trademark of Sony Corporation Bruel amp Kj r reserves the right to change specifications and accessories without notice HEADQUARTERS DK 2850 N rum Denmark Telephone 45 4580 0500 Fax 45 4580 1405 www bks
Download Pdf Manuals
Related Search
Related Contents
Wavemaster Score MINI-ARRAY™ MINI-ARRAY Features 36613_Nass-und Trockensauger_Cover_LB3.indd Classification des chants du nouveau recueil Alléluia, à l`usage des Nikon COOLPIX S9 User's Manual dreamGEAR Silver Edition Powerheart G5 AED Operator/Service Manual FR-21408N-SH15 Copyright © All rights reserved.