Home
EC type-examination certificate UK/0126/0157 Revision 1
Contents
1. 719 VER 5w 1 0 SCALE 491064 1 0 Chk 5601 dcib ARCHIVE VER 240 NET VEH 4 8 0 REMOTE 10 Legal out 4 5 2 Chk 0x7387888 CPU LX DB Engine Copyright by Birdstep Tech Figure 3 Software identification M 140476 e d 0 29g MODEL SELECTA S N 1234 Max speed 80 m min Certification number UK 0126 0157 Temp range 5 C 40 Class R51 XIII 1 Electrical supply voltage and Max 1200 g frequency 220 240 Vac 50 60 Hz Min XIID 50 g Working pressure 400 kPa T 50 to 80 g T 5 35 Gross 80 to 100 g T 5 55 Gross 100 to 1200 g T 5 70 Gross Figure 4 Rating plate example 8 9 A D CONVERTER CALIBRATION BUTTON CALIBRATION SEAL LABEL with countersunk head screw 7 FIXNGSCREW CALIBRATION WINDOW WINDOW FOR CABLES PASSAGES N w 2 w ian 00900 FIXING SCREW w gt w CALIBRATION SEAL LABEL with countersunk head screw WINDOW FOR LOADCELL CABLE PASSAGES FIXING SCREWS Figure 5 Sealing method Crown Copyright 2014 NATIONAL MEASUREMENT OFFICE Department for Business Innovation amp Skills 9 9
2. MARKS 6 1 The CE mark shall be impossible to remove without damaging it The rating plate shall be impossible to remove without it being destroyed The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex of the Directive 2004 22 EC 6 2 Components that may not be dismantled or adjusted by the user load cell A D board CF card must be secured The seals shall bear a securing mark which may be either amark of the manufacturer and or manufacturer s representative or official mark of a verification officer Access to the load cell connection A D board and CF card is prevented by the sealing measure described in Figure 5 7 ALTERNATIVES There are currently no authorised alternatives 9 9 8 ILLUSTRATIONS Figure 1 Selecta typical configuration Figure 2 Display and user interface Figure 3 Software identification Figure 4 Rating plate example Figure 5 Sealing method 9 CERTIFICATE HISTORY ISSUENO ____ DATE DESCRIPTION UK 0126 0157 10 March 2014 Type examination certificate first issued UK 0126 0157 1 12 May 2014 Front page and table 3 1 corrected lt replaced by for the scale interval e 6 9 Figure 1 Selecta typical configuration 1 2 GROSS kg 22 0 0000 Home xArch Plu PLU 0 127 0 18460 0 192 0 218 0 220 0 22740 0 250 Er Figure 2 Display and user interface
3. National Measurement UK 0126 0157 Office 006 Certification EC type examination certificate UK 0126 0157 Revision 1 Issued by The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments Non Prescribed Instruments Regulations 2006 SI 2006 1257 and the Measuring Instruments Non Prescribed Instruments Regulations 2006 which implement in the United Kingdom Council Directive 2004 22 EC this EC type examination certificate has been issued to Societ Cooperativa Bilanciai Via S Ferrari No 16 41011 Campogalliano Modena Italy In respect of a family of automatic checkweighing instruments designated the Selecta and having the following characteristics Maximum capacity Max s 1200g lt 3000 g Minimum capacity Min gt 50 g gt 50 g Scale interval e gt 0 2 g gt 0 5 g Number of scale intervals n lt 6000 Maximum belt speed lt 80 m min Accuracy class XIII 1 The necessary data principal characteristics alterations securing functioning etc for identification purposes and conditions when applicable are set out in the descriptive annex to this certificate This revision replaces previous versions of the certificate Issue Date 12 May 2014 Valid Until 09 March 2024 Reference No TS0101 0022 222 Signatory G Stones ib for Chief Executive Gig National National Measurement Office Stanton Avenue Teddi
4. ck diagram Technical documentation docx A D converter schematics 404801M pdf 404801A pdf 0 Main board CPU schematics PCM 9375 User Manual_ed2 pdf 3 9 Power supply schematics 52050023 01 52050035 01 0500 Dd Sealing Sealing plan docx 3 3 Software 3 3 1 Software identification The software is held on the CF card and comprises legally relevant and non legally relevant parts The software identification shall be as follows The A D Converter software is designated SCALE 491064 x x with x x the release number that may change following minor modifications The A D converter software is fully legally relevant The main board software comprises two parts The legally relevant part is designated LEGAL OUT 4 with x x the release number that may change following minor modifications The non legally relevant part can be freely modified currently designed VER SW 6 1 0 The software identification can be accessed by pressing the bottom right icon then Ver SW Figure 3 3 3 2 Security The legally relevant part of the software can only be accessed by breaking the hardware seal preventing access to the CF card Access via the user interface is prevented The non legally relevant software can be accessed via the user interface or communication ports and can be freely modified 4 PERIPHERAL DEVICES AND INTERFACES 4 1 Interfaces The instrument may have the any of following interface t
5. he weigh platform may be fabricated with steel or aluminium support The weighing device comprises a strain gauge load cell located below the centre of the weigh conveyor The load cell is as follows Tedea load cell type 240 Emax 10 kg 2 1 5 The system uses in feed photocells to detect the arrival and passing of any packs out feed photocells are optional The Auto Zero mode is active when there are no packs on the platform Packs are weighed as they pass over the weigh conveyor which runs continuously at the speed of the in feed and out feed conveyors The weight signal is continually monitored to find the optimal point at which to take the final product weight The analogue output is then sent to the load cell module to be digitised and processed 2 2 Electrical 2 2 1 The control cabinet located behind the conveyors houses the electrical hardware A door at the back of the cabinet allows access to the hardware A D converter board type 404801 main board with CPU type Geode LX 800 500 MHz or equivalent power supplies motor drivers and appropriate relays 2 2 2 A pole mounted display and user interface unit Figure 2 is located above the cabinet and comprises an LCD touch screen The interface allows viewing of weighing parameters and results as well as access to the instrument s various functions 2 9 2 3 Devices The instrument has the following devices Automatic zero setting device active during automatic o
6. ngton TW11 0JZ United Kingdom UKAS Measurement Tel 44 0 20 8943 7272 Fax 44 0 20 8943 7270 Web www gov uk nmo CERTIFICATION Office 0135 MID Annex Rev 3 28 December 2012 NMO is an Executive Agency of the Department for Business Innovation amp Skills Descriptive Annex 1 INTRODUCTION The instruments designated the Selecta are designed to operate as automatic checkweighers Category X The instruments comprise a cabinet a pole mounted display and user interface conveyors a weighing device and mechanical handling facilities The instruments are designed to weigh packs dynamically 2 FUNCTIONAL DESCRIPTION 2 1 Mechanical 2 1 1 The instrument Figure 1 is constructed in stainless steel The framework is a fabricated floor standing stainless steel frame on adjustable feet On the frame are mounted the modular conveyor sections in feed weigh platform and out feed The conveyors type number size and shape are not restricted The out feed conveyor can be equipped with one of a number of reject devices including a flipper drop flap ram or air blast The in feed or out feed conveyors may be equipped with quality control system such as metal detectors or x rays 2 1 2 The instrument is designed to be permanently installed and is fitted with a level indicator located on the weigh platform 2 1 3 The control cabinet is located behind of the conveyors and houses the electrical hardware 2 1 4 Weighing unit T
7. peration at least every 4 min 50 s Semi automatic zero setting lt 4 max Initial zero setting lt 20 max Pre set tare device subtractive Static calibration not accessible to the user Dynamic calibration accessible to the user recorded Dynamic setting Belt speed setting accessible to the user Internal memory for storage of batch data Device acting upon significant faults Screen check at power up High resolution mode 0 16 for testing purposes not accessible to the user 3 TECHNICAL DATA 3 1 The family of instruments has the following technical characteristics Maximum capacity Max lt 1200 g lt 3000 g Minimum p LE Scale interval e Maximum scale n lt 6000 50 to 80g T lt 35 Gross 50 to 80g T lt 35 Gross 80 to 1009 lt 55 Gross 80 to 1009 lt 55 Gross 100 to 12009 T lt 70 Gross 100 to 30009 T lt 70 Gross Dynamic setting 50 g to 300 g 20 preset weight 300 g to 500 g 10 preset weight 500 g to 1200 g 20 preset weight 1200 g to 3000g 240g preset weight Belt speed 5 C to 40 C Climatic environment Non condensing closed Electromagnetic E1 and E2 environments Power supply 220 240 Va c 50 Hz XIII 1 3 2 Documentation and drawings Selecta dimensional drawings 0700067 Selecta assembly drawings Selecta assembly drawngs xlsx Selecta blo
8. ypes Ethernet RS232 RS422 IO board 4 2 Peripheral devices The instrument may be connected to any peripheral device that has been issued with an Evaluatino of Parts certificate by a Notified Body responsible for Annex B MI 006 under Directive 2004 22 EC in any Member State and bears the CE marking of conformity to the relevant directives or A peripheral device without a test certificate may be connected under the following conditions 4 9 it bears the CE marking for conformity to the EMC Directive it is not capable of transmitting any data instruction into the weighing instrument other than to release a printout checking for correct data transmission or validation it prints weighing results and other data as received from the weighing instrument without any modification or further processing and it complies with the applicable requirements of Paragraph 8 1 of Annex I 5 APPROVAL CONDITIONS The following legends are durably and legibly marked on a rating plate located on the instrument Figure 4 CE marking Supplementary metrology marking Notified Body identification number Accuracy class Serial number Manufacturers mark or name Certificate number Model designation Max Min T lt Climatic environment Electromagnetic classification Maximum speed pack rate may be included in the documentation accompanying the instrument 6 LOCATION OF SEALS AND VERIFICATION
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - Electromotive Engine Controls ADAS301: State selective charge exchange data 3Com Wireless 8760 Dual-radio 11a/b/g PoE Access Point Quick Cultures urbaines VPCZ13AHX/XQ SERVICE MANUAL Timex Health Touch HRM User Guide MANUALE DʼISTRUZIONI - Icon Heath & Fitness Proyector Full HD 1080p LightStream™ Copyright © All rights reserved.
Failed to retrieve file