Home

Security door keypad controller

image

Contents

1. 2 UM0408 Getting started 5 After selecting the destination folder click Next The software installation then starts see Figure 7 Figure 7 Installation process InstallShield Wizard Setup Status Security Door Keypad Controller Setup is performing the requested operations Generating script operations for action 6 On completion of the installation process the window shown in Figure 8 opens Click the Finish button Figure 8 Installation complete InstallShield Wizard InstallShield Wizard Complete d Setup has finished installing Security Door Keypad Controller on your computer You will find the software and Help Files have been placed in the installation folder Also a shortcut is available in the Windows Start Menu and on the Desktop ky 9 27 Running the security door application UM0408 2 2 1 Note 10 27 Running the security door application User or standalone mode Powering on the system This is an easy to use system As soon as you plug in the DC power supply 3 4V to 19V through the adaptor the system is up and running All the three status LEDs glow see Figure 9 until the system stabilizes Figure 9 Power on condition all LEDs ON ON ON ON aa DH ERR MEK et Sn nz MN V 7 gt E 39 CR HSC0001 01 After the around 4 5 seconds the system stabilizes and just the green power LED remains
2. Please select the required communication settings COM Port COM1 X Baud Rate y Communication error If the following message appears Figure 15 then it could be due to the following reasons 1 Baud rate mismatch set it to 4800 the red error LED glows 2 RS232 serial cable not connected properly 3 Incorrect COM port selection Figure 15 Communication error message OH Communication Error Acknowledgment Not Received 17 27 Running the security door application UM0408 2 4 6 18 27 Features supported by the GUI Following features are supported by the GUI 1 Add user code Actions Add new user code to the system 2 Delete user code Delete an existing user code from the system 3 Delete all user codes Delete all existing user codes from the system This feature is supported only through GUI 4 Modify user code Replace the existing user code with a new one This feature is supported only through GUI 5 View event log Summary of all the events logged in EEPROM of the system This feature is supported only through GUI 6 Delete event log Delete the EEPROM data This feature is supported only through GUI 7 View code list View all the active user code for the system This feature is supported only through GUI 8 Change admin password Change the admin password This feature is supported only through GUI To select these features you can use either the tool b
3. lt 7 UM0408 N I life augmented User manual Security door keypad controller Introduction This document describes the operation of a keypad controller for use in security door applications The aim is to assist in the development of a keypad decoding system and to display associated information through LEDs for all necessary actions such as power on door open and error The entire system has been developed to target low end and low cost application areas and has been realized with the help of the ST7FLITE39F2 microcontroller A useful additional feature is the support of system protection from physical intrusion using the STM1403 The associated evaluation board order code STEVAL IAS001V1 aims to display the capabilities of ST s general purpose microcontroller to fit the market segment of home automation and security keeping the system cost as low as possible The board can operate in 2 modes m User stand alone mode m Administrator mode through board through PC Graphical User Interface System operation in the various modes is explained through the document sections When the board is connected to the power supply the system enters the user configuration mode Administrator mode can be accessed through the use of a PC where SCI communication is set up and used between the PC and the board through the RS232 At the time of manufacturing an additional board has been connected to allow in circuit programming of t
4. 4 4 leg Push button Through S 1 Switches hole Push Tomm 535 916 4 4 leg Push button Through 9 Switches hole Push Tomm 535 916 4 4 leg Push button Through UI switches hole Push arnel 535 916 4 4 leg Push button Through 1 Switches hole Push ramell 535 916 4 Through hole 85db BZ1 1 DC Buzzer ENER Stuff S E B 20 B DC 1 3V Battery CR2032 Coin type MAXEL MAXELCR2032 BT1 1 Battery Socket BATT C MAXEL MAXELCR2032 R11 R2 R3 z Resistor iok See loc R4 R5 R6 R9 23 27 Bill of materials UMO408 24 27 Table 2 Bill of materials O gt Manufacturer s T Value bi d s oi a 5 S Reference Generic Part Package Manufact Supplier s ordering 8 Supplier code Orderable D 6 Number Part Number R1 R13 3 Resistor 330 0805 Local R14 R10 R12 4 Resistor 10M 0805 Local R7 R8 C1 C10 oe 8 Capacitor 0 1 F 0805 Local C7 C8 C9 C6 1 Capacitor 1 F 10V CAP Local C5 1 Capacitor 2 2 F 10V CAP Local Ji 4 Power Jack for power jack Loval adaptor for adaptor JP1 JP2 SIP 2 berg JP3 4 Jumper strip Local JP4 C11 1 Capacitor 10nF 0805 Local d UMO408 Troubleshooting Appendix D Troubleshooting D 1 D 2 D 3 Note Communication error A Communication error message may appear on the PC screen as in Figure 15 for any of the following reasons 1 Baud rate
5. in System 0 Comi 4800 25 27 Revision history UMO408 3 26 27 Revision history Table 3 Document revision history Date Revision Changes 06 Apr 2007 1 Initial release ore Updated part numbers ST7FLITE39F2 instead of ST7FLITE39 HEH 2 Updated ST logo and Disclaimer UMO408 Please Read Carefully Information in this document is provided solely in connection with ST products STMicroelectronics NV and its subsidiaries ST reserve the right to make changes corrections modifications or improvements to this document and the products and services described herein at any time without notice All ST products are sold pursuant to ST s terms and conditions of sale Purchasers are solely responsible for the choice selection and use of the ST products and services described herein and ST assumes no liability whatsoever relating to the choice selection or use of the ST products and services described herein No license express or implied by estoppel or otherwise to any intellectual property rights is granted under this document If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual pro
6. is T o_o o o e ES F ed 001 x DS mmm am a 6 b gt 2 Re sE Lo o 4 o otitis ee CCS EES E A ae ee a S ADA S ei Eh al E e 001 mor Gem ma o Fo Kl ENO o o o o o o 6 ee ames a oe A tz am 7 ali s t of pa soot NOD 901 O E ACE T TB o o o o o o ors Gear o or o mort NIL of amp T Thomi me SDA tt Cag E sa HAOVAYALNI ZECSA on PXE AVAATA w R TA T S SACH HLS Sp pun ANINAL O80S6N O SS E i if x yI Ee mG 1N HN IN HN ON za EI EE eem O por E O e pi IDA y T SS WO e gt Wor Wor A En am su Jo or S mm ea ny val td a id SDA DA bh h e un WO x01 15 SDA AOU ASONSVEOPLALS Demonstration board schematic AE Es ODA 3 us Ire ie g EA a qa pl 0 va ta D Ce i en VUQ0z 081 AE EODA S et E 0401 4nz 7 e ER E om T pe ear arrage e i a T AA TIOYALNOS AYdAHA BA Ss NOLL 22120 Yad NV L AIAANS NIMOA 9 D z 1 Appendix B UMO408 Bill of materials UMO408 Appendix C Bill of materials Table 2 Bill of materials O gt Manufacturer s Value 5 A 5 c Reference Generic Part Package Manuract Supplier s ordering By Supplier code Orderable o 6 Num
7. on see Figure 10 Figure 10 System stable ready to use ON Grp er w ep hm Yo 3 i Se CR HSC0001 01 Do not perform any operations while the system is stabilizing i e while all three LEDs glow Default system settings The system comes with a number of default settings including the administrator password which is 00000 You are recommended to change this as soon as the system is functional refer to the GUI help UM0408 Running the security door application 2 1 3 Note Valid user code A valid user code is 5 digit long You cannot use 00000 as a code it is reserved for the system default setting A total of 49 user codes are supported by the system Door open Each valid user code entry is presented by the magnetic lock LED yellow glowing see Figure 11 The door remains open for approximately 15 seconds If another command is issued during the door open condition the new command will override and the system will perform accordingly All these events are logged in the EEPROM and can be seen through the GUI Figure 11 Door open condition ON ON 4 prr Ep Mew O 2 oe 39 CR HSC0001 01 Physical intrusion The system has been designed to detect physical tampering Four jumpers have been provided on the board that determine the tamper condition e Normal or no tampering condition This is the default status when both the NL jum
8. ar as shown in Figure 16 or the menu bar see Figure 17 Figure 16 Tool bar Security Door Keypad Controller File View Actions Options Help Ra m r Figure 17 Menu bar Security Door Keypad Controller File View FRE Options Help Add User Code Modify User Code Delete User Code Delete All Users View Event Log Delete Event Log Change Admin Password View Code List For details on each feature and its usage refer to the GUI help manual UMO408 Running the security door application 2 4 7 2 4 8 Note Logoff GUI mode After working in administrator mode through the PC GUI you can choose to log off File Logoff This sends a disconnect command to the board see Figure 18 Then close the GUI window Remove the RS232 serial cable Shortcut By directly closing the GUI window a disconnect command is directly issued to the board Remove the RS232 serial cable All three LEDs glow for 4 5 seconds see Figure 9 Figure 18 Logoff message D 1 You are successfully logged off From the application The system then becomes available to operate in user or administrator modes through the board itself see Figure 10 Automatic Logoff from GUI mode through watchdog The system is designed in such a way to support automatic log off from GUI mode if no communication from PC is received No communication from the PC could be due to e RS232 cable un plugged with
9. ber Part Number ST7FLite39F2 ST7FLite39F2 U4 1 6 MCU M6 SO 20 ST ST7FLite39F2M6 M95080 U3 1 EEPROM WMNG SO 8 ST M95080 WMN6 u2 1 Tamper Detect SE QFN 16 IST STM1403ASNQ6F U1 q Voltage KF33BDT TR DPAK 3 ST KF33BDT TR Regulator U5 q RS 232 ST3232 SO 16 ST ST3232CDR interface D4 1 Diode BAT54J SOD 323 ST BAT54JFILM J2 q Het DB9 F Farnell 105 6112 connector Header 5x2 CON1 1 ICC Connector IDC 10B Farnell 1106782 D l1 LED Green Through Farnell 884 698 hole D2 1 LED Red Through Farnell 942 492 hole D3 1 LED Yellow Through Farnell 942 455 hole 4 leg Push button Through g Switches hole Push Parnell 995 916 4 4 leg Push button Through 1 switches hole Push Parnell 935 916 4 4 leg Push button Through 2 Switches hole Push Parnell 999 916 4 4 leg Push button Through S 1 switches hole Push Parnell 995 916 4 22 27 ky UMO408 Bill of materials d Table 2 Bill of materials S Manufacturer s IS Value bd s wier f 5 E Reference Generic Part Package Manufact Supplier s ordering S Number Supplier code Orderable i Part Number 4 leg Push button Through 4 switches hole Push Tomm 535 916 4 4 leg Push button Through R 1 switches hole Push Farnell 535 916 4 4 leg Push button Through j switches hole Push Tomm 535 916 4 4 leg Push button Through 1 Switches hole Push Tomm 535 916
10. d herein and shall not create or extend in any manner whatsoever any liability of ST ST and the ST logo are trademarks or registered trademarks of ST in various countries Information in this document supersedes and replaces all information previously supplied The ST logo is a registered trademark of STMicroelectronics All other names are the property of their respective owners 2013 STMicroelectronics All rights reserved STMicroelectronics group of companies Australia Belgium Brazil Canada China Czech Republic Finland France Germany Hong Kong India Israel Italy Japan Malaysia Malta Morocco Philippines Singapore Spain Sweden Switzerland United Kingdom United States of America www st com 4 27 27
11. e the red error LED glows for approximately 12 seconds After this the system exits admin mode No new user code is added to the system The adding new user event is logged in the EEPROM and can be seen through the GUI You are not allowed by the system to add 00000 or admin password as user code Any attempt is handled as user code already exists and the red error LED glows for approximately 12 seconds and the system exits admin mode 13 27 Running the security door application UM0408 2 2 2 Delete user code To delete a user code from the system follow the steps shown below Press the key The red error LED starts flashing indicating that you are in administrator mode Enter the admin password within 1 minute 1 If the admin password is valid the red error LED flashes 6 times If the admin password is wrong the red error LED glows for approximately 12 seconds After this the system exits admin mode Also this event is logged in the EEPROM as Invalid Password Error and can be seen through the GUI If the admin password is not entered within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode Press the key within 1 minute If is pressed the system checks if there is any user code in the system to be deleted If yes the red error LED flashes 6 times Otherwise no user code to delete the red error LED flashes 30 times and the system exits admi
12. er for the security door evaluation package is orderable with the following order code STEVAL IAS001V1 It includes e Hardware One demonstration board e Software PC executable software to be used along with the demonstration board e Documentation User manual The firmware source code C language is not included in the evaluation package Please contact your ST sales office to request it Hardware installation The demonstration board can be powered through an external power supply using a DC adaptor 3 4V to 19V It is not included within the ST evaluation package UM0408 Getting started Figure 1 Security door keypad controller front view oh Vw ET ga E on LO Fey pr 3 status LEDs O CR HSCOOO1 01 O External power supply jack 4x3 key matrix O O RS232 female socket O HE10 ICC 4 jumpers for peer a connector physical intrusion configuration The major components present on the front of the board are see Figure 1 An external power jack for the DC adaptor 3 status LEDs for power error and magnetic lock 4x3 key matrix to enter the user code 4 jumpers for physical intrusion detection An RS232 female socket An HE10 connector for ICC programming DARAN ky 5 27 Getting started UM0408 Figure 2 Security door keypad controller back view B e uzzer KF33 O Battery ST7FLite39F2 O M95080 O O STPM1403 ST3232C The major componen
13. er mode Refer to Section 2 1 1 on page 10 The first GUI window login GUI mode Opening the GUI executable the first window appears as shown in Figure 13 Figure 13 First GUI window Security Door Keypad Controller Verify Administrator Password EIS File View Actions Options Window Help Ra RANG Verify Administrator Pass O E3 Please enter Administrator password to login the application com BaudRate 4800 Enter the administrator password If correct administrator mode is entered and all features are available Otherwise an invalid password error message appears For details on each feature and its usage refer to the GUI help manual When in GUI mode the system cannot be used or configured in user or administrator modes configuration from the board itself UM0408 Running the security door application 2 4 4 Note 2 4 5 Communication setting Ensure that the communication settings between the board and GUI are as follows e baud rate is set to 4800 e right COM port is selected Follow the steps below to configure the communication settings through the GUI see Figure 14 1 Goto Options Connection Settings 2 Choose the serial communication port to which board is connected 3 Choose the baud rate 4800 4 Click OK The chosen settings are automatically saved for future sessions Figure 14 Communication settings window Connection Settings
14. ered within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode Press the key within 1 minute If is pressed the system checks if there is space to accommodate a new user If yes the red error LED flashes 6 times Otherwise no additional users can be added and the red error LED flashes 30 times and the system exits admin mode If any other key is pressed the red error LED glows for approximately 12 seconds After this the system exits admin mode If no key is pressed within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode Enter the new user code to be added within 1 minute If a 5 digit user code is entered the system checks if it exists If not found the red error LED flashes 6 times If it exists the red error LED glows for approximately 12 seconds and the system exits admin mode If user code is not entered within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode Press the key within 1 minute If is pressed this is confirmation by the user to add the user code The system is updated and the red error LED flashes 18 times After this the system exits admin mode If any other key is pressed the red error LED glows for approximately 12 seconds After this the system exits admin mode No new user code is added to the system If no key is pressed within 1 minut
15. eset through board 14 2 4 Administrator mode through PC graphical user interface 15 2 4 1 Connecting to the PC ananasa anana 15 2 4 2 Powering on the board 0 cee ee 16 2 4 3 The first GUI window login GUI mode 16 2 4 4 Communication setting 16 2 4 5 Communication error 1 0 0 0 eee 17 2 4 6 Features supported by the GU 18 2 4 7 Logoff GUI mode 19 2 4 8 Automatic Logoff from GUI mode through watchdog 19 Appendix A AbbreviationS 0c cece ee 20 Appendix B Demonstration board schematic o0o ooooooo 21 Appendix C Bill of materials lt lt lt lt lt lt oooooooorrannnn 22 2 27 Ti UM0408 Contents Appendix D Troubleshooting 000 cc eee eee eee eee 25 D 1 Communication error 25 D 2 TNA a a 25 D 3 Delete all USES ca ai de a Bas ek 25 3 Revision history ociosos a o wince aw a we ee 26 ky 3 27 Getting started UM0408 1 1 Note 1 2 1 3 4 27 Getting started System requirements The system can operate in standalone mode by powering it externally using a power supply adaptor 3 4V to 19V For the system to be connected to a PC for administrator use a recent version of Windows such as Windows 2000 or Windows XP must be installed on the PC The version of the Windows OS installed on your PC can be determined by clicking on the System icon in the Control Panel Package contents The keypad controll
16. he microcontroller The two can be easily disconnected so that the keypad controller for the security door evaluation board can be used independently To summarize the key features of the evaluation board include 4x3 key matrix 3 LEDs green for power red for error and yellow for magnetic lock 4 jumpers for physical intrusion detection with battery back up and buzzer On board SPI EEPROM for event logging On board RS232 driver to interface with the PC Power supply adaptor 3 4V 19V Embedded in circuit programming capability April 2013 Rev 2 1 27 www st com Contents UM0408 Contents 1 Getting started it ac na no i Sa me i ing a io 4 1 1 System requirements 4 1 2 Package contents vascas raras UR 4 1 3 Hardware installation siss2s0ckceetiaxdeaseoeciaeae da da aoe oe 4 1 4 Software installation anaana ite AER he ER iter Seba ees Ba EE 6 2 Running the security door application lt lt lt 10 2 1 User or standalone mode 10 2 1 1 Powering on the system 10 2 1 2 Default system settings 10 2 1 3 Valid user code 11 2 1 4 DOO OPON ee nee A ween Be 11 2 1 5 Physical intrusion 0 terei measar enea a a E EEG 11 2 1 6 Error conditions in user mode 2 00 0 eee 11 2 1 7 User code tampering 0 naana 12 2 2 Administrator mode through board 000 eee eee eee 12 2 2 1 Add new user code 12 2 2 2 Delete user code 13 2 3 Administrator password r
17. he system exits from admin reset password mode If nothing is entered within 1 minute the red error LED glows for approximately 12 seconds After this the system exits from admin reset password mode 6 Press the key within 1 minute If is pressed this is confirmation for the administration password reset to 00000 The red error LED flashes 18 times The system exists from the admin reset password mode Ifan incorrect key is pressed the red error LED glows for approximately 12 seconds The administrator password is not reset and the system exits from admin reset password mode f no key is pressed within 1 minute the red error LED glows for approximately 12 seconds The administrator password is not reset and the system exits from admin reset password mode 2 4 Administrator mode through PC graphical user interface 2 4 1 Connecting to the PC Connect the RS232 serial cable between the demonstration board and the PC and power on the board Note Even if the board is connected with the RS232 serial cable with power on the system enters the GUI mode as soon as the administrator password is entered in the login window You 15 27 Running the security door application UM0408 2 4 2 2 4 3 Note 16 27 need to make sure that the system is not in the process of executing another command at this time otherwise unexpected behavior is possible Powering on the board This is the same process as with the us
18. mismatch set it to 4800 signaled by the red error LED glowing 2 RS232 serial cable not connected or not connected properly 3 Incorrect COM port selection set it to correct setting based on the PC configuration 4 Board not power on In all the above cases the user needs to re start the GUI 5 Red error LED glowing For this case when the Error LED red turns off then the user needs to re start the GUI Time out error The Time out error See Figure 19 is shown when the command issued by the user takes longer to finish than expected by the system on the GUI side though the operation is completed on the board side In this case the user needs to re start the GUI to get the real system status Figure 19 Time out error x Error Timeout occured while Reading Delete all users Deleting all users is a time consuming process To ensure that this is completed after receiving the OK prompt from the GUI see Figure 20 make sure that the Code in system 0 in the status bar Wait a little longer if this has not been updated As soon as the status bar displays Code in system 0 the system is ready for next command see Figure 21 If any command is sent and the delete all users operation is not complete system behavior is not guaranteed Figure 20 Delete all users OK window H 1 Alluser codes deleted Figure 21 Delete all users Status bar Ready Total Code Capacity 49 Codes
19. n mode If an incorrect key is pressed the red error LED glows for approximately 12 seconds After this the system exits admin mode If no key is pressed within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode Enter the user code to be deleted within 1 minute If a 5 digit user code is entered the system checks if it exists If it exists the red error LED flashes 6 times If not found the red error LED glows for approximately 12 seconds and the system exits admin mode If a user code is not entered within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode Press the key within 1 minute If is pressed this is confirmation by the user to delete the user code The system is updated and the red error LED flashes 18 times After this the system exits admin mode If an incorrect key is pressed the red error LED glows for approximately 12 seconds After this the system exits admin mode No user code is deleted from the system If no key is pressed within 1 minute the red error LED glows for approximately 12 seconds After this the system exits admin mode No user code is deleted from the system Deleting a user event is logged in the EEPROM and can be seen through the GUI Note The system prevents the admin password from being deleted Any attempt to do so is handled as user code not found and the red error LED glow
20. out proper log off from the GUI e GUI idle for long time no serial communication between PC and board In this situation the system watchdog is activated for approximately 30 seconds After that the system resets all the three LEDs start glowing for 4 5 seconds see Figure 9 The system then becomes available to operate in user or administrator modes through the board itself see Figure 10 As this is a case of improper log off it is desirable that when the serial communication is re established between the PC and board the user should re login to view the real status Otherwise the status on the GUI may not be updated 19 27 Abbreviations UMO408 Appendix A Abbreviations 20 27 Table 1 Abbreviations No Acronym Definition 1 RTC Real Time Clock 2 PC Personal Computer 3 EEPROM Electrically Erasable Programmable Read Only Memory 4 SPI Serial Peripheral Interface 5 LED Light Emitting Diode 6 SCI Serial Communication Interface 7 OS Operating System 8 ICC In circuit communication 9 Admin Administrator Demonstration board schematic 21 27 9 s S 1301 ems ES ro are at a fo ON DMG oNWSod
21. pers JP2 JP4 are closed and both the NH jumpers JP1 JP3 are open The buzzer is off e Tampering normal low This is the tamper condition when either or both of the NL jumpers JP2 JP4 are open and both the NH jumpers JP1 JP3 are open The buzzer is on e Tampering normal high This is the tamper condition when both the NL jumpers JP2 JP4 are closed and either or both of the NH jumpers JP1 JP3 are closed The buzzer is on There can be various cases of tampering based on the 4 jumper settings All are supported by the system and the buzzer is always on in the event of tampering For details on the tamper detection circuit and design refer to STM1403 data sheet 11 27 Running the security door application UM0408 2 1 6 Note 12 27 Error conditions in user mode There are various error states for this system as explained below For each of the errors encountered the red error LED glows see Figure 12 for approximately 4 5 seconds 1 Wrong 5 digit user code The user enters a 5 digit user code which does not match any of the valid user codes already added in the system This event is logged in the EEPROM and can be seen through the GUI 2 Time out condition between 2 key presses The gap between two key press events exceeds 5 seconds Figure 12 Error condition ON ON o P ER ERF 2 2 o F Ee S CR HSCOO01 01 User code tampering When the user consecutively enters
22. perty contained therein UNLESS OTHERWISE SET FORTH IN ST S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT ST PRODUCTS ARE NOT AUTHORIZED FOR USE IN WEAPONS NOR ARE ST PRODUCTS DESIGNED OR AUTHORIZED FOR USE IN A SAFETY CRITICAL APPLICATIONS SUCH AS LIFE SUPPORTING ACTIVE IMPLANTED DEVICES OR SYSTEMS WITH PRODUCT FUNCTIONAL SAFETY REQUIREMENTS B AERONAUTIC APPLICATIONS C AUTOMOTIVE APPLICATIONS OR ENVIRONMENTS AND OR D AEROSPACE APPLICATIONS OR ENVIRONMENTS WHERE ST PRODUCTS ARE NOT DESIGNED FOR SUCH USE THE PURCHASER SHALL USE PRODUCTS AT PURCHASER S SOLE RISK EVEN IF ST HAS BEEN INFORMED IN WRITING OF SUCH USAGE UNLESS A PRODUCT IS EXPRESSLY DESIGNATED BY ST AS BEING INTENDED FOR AUTOMOTIVE AUTOMOTIVE SAFETY OR MEDICAL INDUSTRY DOMAINS ACCORDING TO ST PRODUCT DESIGN SPECIFICATIONS PRODUCTS FORMALLY ESCC QML OR JAN QUALIFIED ARE DEEMED SUITABLE FOR USE IN AEROSPACE BY THE CORRESPONDING GOVERNMENTAL AGENCY Resale of ST products with provisions different from the statements and or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service describe
23. s for approximately 12 seconds and the system exits admin mode 14 27 UM0408 Running the security door application 2 3 Administrator password reset through board In the event that the administrator password is forgotten it can be reset to the default value of 00000 This is done as follows 1 Press the key The red error LED starts to flash indicating that you are in administrator reset password mode 2 Enter 12345 within 1 minute If correctly entered the red error LED flashes 6 times If incorrectly entered the red error LED glows for approximately 12 seconds After this the system exits admin reset password mode If nothing entered within the 1 minute the red error LED glows for approximately 12 seconds After this the system exits from admin reset password mode 3 Press the key within 1 minute If is pressed the red error LED flashes 18 times Ifan incorrect key is pressed the red error LED glows for approximately 12 seconds After this the system exits from admin reset password mode f no key is pressed within 1 minute the red error LED glows for approximately 12 seconds After this the system exits from admin reset password mode 4 Press the key The red error LED flashes 6 times 5 Enter 54321 within 1 minute Ifa correct entry is made the red error LED flashes 6 times Ifan incorrect entry the red error LED glows for approximately 12 seconds After this t
24. three wrong 5 digit user codes within 10 minutes the system enters a user code tampering state This condition is presented by the red error LED see Figure 12 glowing for approximately 10 minutes During this time the magnetic lock is disabled This event is logged in the EEPROM This condition can be exited in one of two ways either by waiting for 10 minutes or by entering the administrator password to return the system back to a normal state which returns the LEDs back to just green Power This event is also logged in the EEPROM All the logged events can be seen in the GUI While the system is in the user code tampering state no other commands except the entering of the administrator password are acknowledged by the system either through the keys or through the GUI UMO408 Running the security door application 2 2 2 2 1 Note Administrator mode through board Add new user code To add a new user code to the system follow the steps below Press the key The red Error LED starts flashing indicating that you are in administrator mode Enter the admin password within 1 minute 1 If the admin password is valid the red error LED flashes 6 times If the admin password is wrong the red error LED glows for approximately 12 seconds After this the system exits admin mode Also this event is logged in the EEPROM as Invalid Password Error and can be seen through the GUI If the admin password is not ent
25. ts present on the back of the board are see Figure 2 1 A buzzer for physical intrusion detection 2 Acoin type battery as back up for the tamper detection device in the event of power failure KF33B voltage regulator ST7FLITE39F2 microcontroller M95080 EEPROM for data logging STM1403 tamper detection device ST3232C RS232 driver NOAA w 6 27 ky UM0408 Getting started 1 4 Software installation To install the PC GUI follow the steps described below 1 Double click the Security Door executable icon The window shown in Figure 3 opens Figure 3 Installation window InstallShield Wizard ES Welcome to the InstallShield Wizard for Security Door Keypad Controller The InstallShield Wizard will install Security Door Keypad Controller on your computer To continue click Next Ge 2 Click Next to move to the License Agreement window shown in Figure 4 Read the license and if you accept it click Yes Figure 4 License agreement InstallShield Wizard License Agreement a A Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement SOFTWARE LICENSE AGREEMENT 1 IMPORTANT Before loading this software you have to carefully read and agree to the following terms and conditions which will be then automatically agreed on by loading this Software or any portion thereof If you do not agree to the terms of this Agreement do not install or
26. use this software or any portion thereof 2 LICENSE GRANT Do you accept all the terms of the preceding License Agreement If you choose No the setup will close To install Security Door Keypad Controller you must accept this agreement nstallShield lt Back Yes No 4 7 27 Getting started UM0408 8 27 3 The Customer Information window opens as shown in Figure 5 Enter the relevant information and click Next Figure 5 Customer Information InstallShield Wizard Customer Information Please enter your information User Name john Company Name _ _ _ Install this application for e Anyone who uses this computer all users C Only for me stm lt Back Next gt Cancel 4 Now select the folder in which you want to install the software see Figure 6 By default the software is installed to the following path C Program Files STMicroelectronics SecurityDoorKeypad Figure 6 Select installation folder InstallShield Wizard Choose Destination Location Select folder where Setup will install files Setup will install Security Door Keypad Controller in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder Destination Folder Ch Ap TMicroelectronics S ecurityD oorkeypad Browse InstallShield lt Back Next gt Cancel

Download Pdf Manuals