Home

OpenVox® B800P User Manual - VoIP

image

Contents

1. 3 Downloading unzipping and compiling driver A Download the stable version of bristuff drivers from http www junghanns net and copy the tar file to usr sre cp bristuff lt versiom tar gz usr src cd usr src tar xvzf bristuff lt versiom tar gz B Download OpenVox patch called gozap c from www openvox com cn It contains a patched qozap c file User overwrites the orginal gozap c file with the new qozap c under usr src bristuff lt version gt qozap 8 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual C Make links with kernel source In s usr src kernels 2 6 18 8 el5 i686 usr src linux 2 6 Here under usr src there is kernel source user must create link linux 2 6 under usr sre There are many files under usr sre bristuff 0 3 0 PRE ly j please check d U 3 ff Asterisk CHANGES download sh ISDNguard libpri Bsterisk 1 2 23 compile sh INSTALL libgsmat libpri 1 2 4 asterisk 1 2 23 tar cwain install sh libgsmat 0 0 2 libpri 1 2 4 tar root new host bristuff 0 3 0 PRE 1y j cd root new host src f cd bristuff 0 3 0 PRE 1y j root nev host bristu ff 0 3 0 PRE 1y j 15 asterisk CHANGES download sh ISDNguard libpri asterisk 1 2 23 compile sh INSTALL libgsmat libpri 1 2 4 asterisk 1 2 23 tar cwain install sh libgsmat 0 0 2 libpri 1 2 4 tar root new host bristuff 0 3 0 PRE 1ly j ls 1 otal 27188
2. root 15 Sep asterisk gt asterisk 1 2 23 root 4096 Sep asterisk 1 2 23 root 19005440 asterisk 1 2 23 tar root 18405 CHANGES root 2181 compile sh root 4096 cwain root 781 dovnload sh root 2377 INSTALL root 40 install sh root 4096 ISDNguard root 14 H libgsmat gt libgsmat 0 0 2 root 4096 libgsmat 0 0 2 root 12 8 libpri gt libpri 1 2 4 1000 4096 D libpri 1 2 4 root 348160 H libpri 1 2 4 tar root 4096 U patches root 4096 D gozap root 558 36 Fun download sh root 4096 H SAMPLES root 4096 TESTING root 4096 D zaphfc root 13 5 zaptel gt zaptel 1 2 19 root 12288 07 zaptel l c 15 mr root 8345600 E zaptel 1 2 19 tar drvyxr xr x root 4096 ztgsm root new host bristuff 0 3 0 PRE 1y j I Hdruxr sr x LV L I ru r r IVXIUXIVX druxr xr x EUXEWXEWX IV I I IW I I druxr xr x LEWXEUXEUWX druxr xr x LEWXEUXEUWX druxr xr x Aruxr xr x ArWxr xr x AC WXE XO X Aruxr xr x ArWxr xr x sa Go bo Dt BB E EE OH m o UrWxr Xxr Xx or Figure 3 Files underbri D Compiling Bristuff cd usr sre usr sre bristuff 0 3 0 PRE 1y j chmod 777 install sh install sh Those steps will install zaptel libpri qozap and Asterisk After finishing those steps if user installs Asterisk for first time under the source of Asterisk directory running make samples 9 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox
3. www prsol com images cpd ethernet 568b jpg Trademarks and Copyrights in this user manual e Asterisk is a registered trademark of Asterisk Junghanns NET is trademark of Gesellschaft f r Internet Services und Software Development mbH mISDN is copyright of mISDN org OpenVox is a registered trademark of ShenZhen OpenVox Technologies LTD 20 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Chapter 5 Hardware Setting EN OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 6693mil B800P Jumper Setting Termination of S T Interface 100 ohm NT TE Settings Set jumper to the left Set jumper to the right Power feeding Connector Connect Power feeding to feed IE S T ineterfaces enable Open Power feeding to feed S T ineterfaces disable Select NT mode Select TE mode h Connect Termination ON A Open Termination Off NT TE NO 4 NT TE NO 5 MNN TELET TR400 TR500 PCM OUT CON101 CON801 CON201 CON701 CON301 CON6O1 HHI UT SW401 SW501 OpenVox 123456 CON501 CON401 TR100 TR800 TR200 TR700 TR300 TR600 C ight C 2007 ON mm _ St ii S5 e SE OFF mm B800P C wm Ver 1 0 EE J un mt mt NN Power Supply
4. Selection Power feeding Input 12V Input of Power feeding Boje 3 3V supply from the PCI Slot only available in 3 3V PCI Slot ofe 9 3 3V Supply from the Regulator defult State Indicator Led
5. 4 Tel OpenVox User Manual D Power Feeding Input If one of the eight power feeding connectors is CONNECT ON user should connect a D type connecter from pc power supply to this jack the D type connecter is used to provide power to your CDROM ahd 3 5 HDD E Power Supply Selection Some newest model PCs do not provide 5V on the PCI slots at those cases use has to set the jumper to 3 3 F PCM IN PCM OUT These are for future usages 2 Power off PC remembering unplug the AC power cable 3 Insert B800P card into a 3 3V or 5 0V PCI slot 4 Plug the hard disk power supply cable D style to power feeding input jack if needing providing power to external eguipments please refer jumper setting section for the detail 5 Plug back the AC power cable and power on PC If user wants to know the details about hardware configuration of B800P please refer hardware setting section 2 Software Installation and Setup B800P supports original Bristuff driver form junghanns net Users can download it from http www junghanns net There are few steps to install the driver drivers 1 Checking the B800P hardware by command lspci vvvvvvvvv The card information should be found like figure 2 02 04 0 ISDN controller Cologne Chip Designs GmbH ISDN network Controller HFC 55 rev Dil Subsystem Cologne Chip Designs GmbH Unknown device e998 Control I O Mem BusMaster SpecCycle MemWINV VGASnoop ParErr Ste
6. 5 Hardware Setting 21 3 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Chapter 1 Overview 1 What is B800P B800P is a PCI 2 2 compliant card supporting 8 BRI S T interfaces with an onboard multi NT power feeding circuits NT TE mode can be individually configured on each of the 8 interfaces B800P can be implemented for building Open Source Asterisk based systems such as ISDN PBX and VolP gateway Target Applications High Performance ISDN PC Cards ISDN PABX for BRI VoIP Gateways ISDN LAN Routers for BRI ISDN Least Cost Routers for BRI ISDN Test Equipment for BRI Main Features Eight integrated S T interfaces ITU T 1 430 and TBR 3 certified and S T ISDN supporting in TE and NT mode Integrated PCI bus interface Spec 2 2 for 3 3V and 5V signal environments DTMF detection on all B channels Multiparty audio conferences bridge Onboard power feeding for 8 NT interfaces PCM bus connectors daisy chaining Each of the 8 interfaces can be independently configured for TE or NE mode Full software and hardware compatible with Junghanns NET Bristuff driver and mISDNO driver Application ready use Asterisk to build your IP PBX Voicemail system RoHS compliant Certificates CE FCC 2 What is Asterisk The Definition of Asterisk is described as follow Asterisk is a complete PBX in software It runs on Linux BSD Windo
7. OpenVox User Manual OpenVox RUITER RAF OpenVox Best Cost Effective Asterisk Cards OpenVox B800P User Manual Written by James zhu Email james zhu openvox cn Zhulizhong gmail com Date 7 11 2007 Version 001 1 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual OpenVox RUITER RAF OpenVox Best Cost Effective Asterisk Cards OpenVox Communication Co Ltd Address F 2 Building No 14 Shangsha Science amp Technology Park No 9283 Binhe Road Futian District ShenZhen Guangdong 518048 China Tel 86 755 82535095 82535461 Fax 86 755 82535174 E Mail sales openvox com cn IM for Sales betty yljiang hotmail com rubyzhangl217 hotmail com IM for Technical Support support openvox com cn zhulizhong gmail com zhulizhongum hotmail com Business Hours 9 30AM 17 30PM from Monday Friday URL www openvox com cn Thank You for Choosing OpenVox Products 2 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Table of Contents Chapter I Deervlegess seess eneen Chapter 2 Card Installation and Configuration een see ee 6 Chapter 3 F amp sees see EE EE EE EE nenn EE EE EE nennen en en essen nennen nennen nn 14 Chapter 4 References een nennen nenne nennen enne OG Chapter
8. User Manual E Modifying and loading modules for zaptel and gozap vi etc zaptel and edit the zaptel conf like this loadzone nl defaultzone nl span 1 1 1 ccs ami termtype te bchan 1 2 dchan 3 span 2 2 1 ccs ami termtype te bchan 4 5 dchan 6 span 3 3 1 ccs ami termtype te bchan 7 8 dchan 9 span 4 4 1 ccs ami termtype te bchan 10 11 dchan 12 span 5 5 1 ccs ami termtype te bchan 13 14 dchan 15 span 6 6 1 ccs ami termtype te bchan 16 17 dchan 18 span 7 7 1 ccs ami termtype te bchan 19 20 10 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual span 8 8 1 ccs ami termtype te bchan 22 23 dchan 24 vi etc Asterisk zapata conf and edit the zapata conf like this Zapata telephony interface Configuration file channels Default language en EEE switchtype euroisdn p2mp TE mode for connecting ISDN lines in point to multipoint mode signalling bri cpe ptmp p2p TE mode for connecting ISDN lines in point to point mode signalling bri_cpe p2mp NT mode for connecting ISDN phones in point to multipoint mode signalling bri net ptmp p2p NT mode for connecting an ISDN pbx in point to point mode signalling bri net pridialplan local prilocaldialplan dynamic nationalprefix 0 internationalprefix 00 priin
9. dication passthrough echocancel yes context demo group 1 S T port 1 11 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual channel 1 2 group 2 S T port 2 context demo channel gt 4 5 group 3 S T port 3 context demo channel gt 7 8 group 4 S T port 4 context demo channel gt 10 11 group 5 S T port 5 context demo channel gt 13 14 group 6 S T port 6 context demo channel gt 16 17 group 7 S T port 7 context demo channel gt 19 20 group 8 S T port 8 context demo channel gt 22 23 cd usr sre bristuff 0 3 0 PRE ly j qozap modprobe zaptel insmod gozap ko for kernel 2 6 12 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual ztcfg VVVVVVVVVVVVVVV F If user wants to modify the dialpaln for particular needs user can edit zaptel conf zapata conf and extensions conf file under etc Asterisk and makes sure Asterisk runs successfully Asterisk vvvvvvvvvvgc Notes Test environments OS Centos 5 Kernel version 2 6 18 8 15 Bristuff version Bristuff 0 3 0 PRE 1y j Hardware OpenVox B800P under TE mode 13 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox Use
10. e user sets 5 and 6 with off status Therefore the dips should be Oxf and cid 15 Figure 6 shows that if user runs dmesg the dips and cid are shown as what user has configured before Fapata Telephony Interface Registered on major 196 Faptel Version 1 2 19 Faptel Echo Canceller MG2 PCI Enabling device 0000 02 04 0 0000 gt 0003 ACPI PCI Interrupt 0000 02 04 0 A gt GSI 18 level low gt IRQ 169 Hips Oxf cid 15 Hozap OpenVox BSOOP card configured at io port Oxa000 IRQ 169 HZ 1000 Hozap S T ports 8 NT NT NT TE TE TE TE TE Hozap 1 multiBRI card s in this box 8 BRI ports total bloop 0 pemslave 0 Registered tone zone O United States North America Figure 6 Show cardid 15 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Figure 7 shows that the 5 and 6 are switched to be off the value should be 001111 CARDID Setting S5 SREL JJEBE 001111 Figure 7 Cardid_setting How to check the pin assignment for RJ 45 To connect with ISDN equipments RJ 45 is used to make connection User should know about RJ 45 standard Here figure 9 and figure 10 show cables and jacks for B800P 16 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Figure 9 Cable Source http www ertyu org steven nikk
11. el images tpcable jpg 12345678 3 O O OIB BG BIB Pair 4 A Source http www prsol com images cpd ethernet_568b jpg Figure 10 Cable_RJ45 17 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Figure 11 shows the pin assignments Pin Assignments For Rj 45 Figure 11 Pin assignment Figure 12 shows the connection in TE mode The Jack will be split into two jacks The one is for 3 4 5 6 and second one is for 1 2 7 8 OPENVOX B800P TE MODE O Figure 12 TE mode Connection 18 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual How to monitor the LEDs of B800P The style of LEDs of B800P is different with B200P B400P If the system loads zaptel qozap and Asterisk successfully in B200P B400P the LEDs will start blinking but in B800P it will not turn to be active until ISDN cable plug into ports the LEDs will be turned into green 19 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Chapter 4 References www Openvox com cn www Asterisk org www voip info org www misdn org http www junghanns net de download html http www ertyu org steven nikkel images tpcable jpg http
12. ould be set to 1 and so on The first card is a card that will be initialized i e installing driver first when system is booting At most of cases Linux will initialize PCI devices according to PCI slot order The slot is nearest to the CPU will be initialized first the slot at the far end from CPU will be initialized at last That is to say that if user has more than one cards of B800P in pc the one is nearest to CPU should be set to card id 0 For more details about Card ID please check F amp Q section Adjusting Termination of S T Interface 100 ohm 1 Za If a port works on NT mode user should set jumper to CONNECT ON If a port works on TE mode Theoretically it should be to OPEN OFF but user might connect to some non standard isdn terminal eguipments that do not have terminal resistors If you have such eguipments you should set it to CONNECT ON Power Feeding Connector These jumpers control whether the card will feed power to the external isdn terminal User should adjust accordingly based on these produces If the port will work on TE mode user MUST set the jumper to OPEN OFF lt If this port will work on NT mode the ISDN terminal requires ISDN power supply user should set the jumper to CONNECT ON ISDN terminal does not require ISDN power supply user should set the jumper to OPEN OFF 6 OpenVox Communication Co Limited Written by James zhu 86 755 82535095 822535461 Fax 86 755 8253517
13. pping SERR FastB2B Status Cap 66MHz UDF FastB2B ParErr DEVSEL medium gt T bort lt T bort lt M bort gt SERR lt PERR Interrupt pin A routed to IRG 169 Region 0 I O ports at a000 size 8 Region 1 Memory at 7004000 32 bit non prefetchable size 4E capabilities 40 Power Management version 2 Flags PMECIE DSI Dit D2 duxCurrent Omi PME DO D1 D2 D3hot D3cold Status DO PME Enable DSel 0 D cale 0 PME Figure 2 PCI_B800P 7 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual 2 Checking the supporting packages If there is no kernel source in the system user should install it User can run yum again yum install kernel devel If user runs this command yum will install the sources for your current version of the kernel Please check the availability of some other packages rpm rpm rpm rpm rpm rpm rpm rpm rpm rpm rpm q bison q bison devel q ncurses q ncurses devel q zlib q zlib devel q openssl q openssl devel q gnutls devel 7q gcc g gcee ctt If any of those packages is not installed install them by using yum yum yum yum yum yum yum yum yum yum yum yum install bison install bison devel install ncurses install ncurses devel install zlib install zlib devel install openssl install openssl devel install gnutls devel install gcc install gec c
14. r Manual Chapter 3 F amp Q How to set the ports under NT mode Please adjust the interface into NT status first and load gozap ko like this modprobe zaptel insmod gozap ko ports X ztcfg vvvvv Here X is bitmap associating with port configuration of B800P The example here is User sets 1 2 and 3 are NT mode 4 5 6 7 and 8 are TE mode X binary 00000111 X Decimal 7 Therefore insmod gozap ko ports 7 refer figure 4 and figure 5 to check the NT setting 4 8 TE Mode 1 3 NT Mode Figure 4 NT_mode 14 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox User Manual Zapata Telephony Interface Registered on major 196 zaptel Version 1 2 19 zaptel Echo Canceller Mid no version for et receive found kernel tainted POI Interrupt O000 02 04 0 4 gt GSI 18 level low gt IRQ 169 Ox3f cid 63 OpenVox BS00P card configured at io port Oxanod IBRO 169 HZ 1000 S T ports 8 NT NT NT TE TE TE TE TE i multiERI card s in this box 5 BRI ports total bloop O pemslave O Figure 5 Show NT How to adjust the card id User can switch Card ID from S5 labeled in figure 13 The default is ON 1 therefore the value will be 0x3f if user wants to insert more than one cards in pc slot user should adjust the CardID An example is given her
15. ws emulated and provides all of the features you would expect from a PBX and more Asterisk does voice over IP in four protocols and can interoperate with almost all standards based telephony equipment using relatively inexpensive hardware 4 OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 User Manual OpenVox PC Softphome E mail CRM System Astarisk PBX Figure 1 Asterisk Setup Source http www siriusit co uk uploads images consulting Asterisk Setup gif Asterisk provides Voicemail services with Directory Call Conferencing Interactive Voice Response Call Queuing It has support for three way calling caller ID services ADSI IAX SIP H 323 as both client and gateway MGCP call manager only and SCCP Skinny voip info org o OpenVox Communication Co Limited Written by James zhu Tel 86 755 82535095 822535461 Fax 86 755 82535174 OpenVox Li User Manual Chapter 2 Card Installation and Configuration Hardware Installation and Setup 1 Configure the Jumper Settings Please check the jumper setting first To install B800P user should follow these steps A B Setting Card ID Switch User should pay attention to the card id switch if user wants to install more than one cards of B800P in one pc Please follow these produces l The card id of the first card should be set to 0 and the second card sh

Download Pdf Manuals

image

Related Search

Related Contents

CADIXE (Projet Caderige : http://caderige.imag.fr/) Manuel d  Guide d`installation rapide  User Manual USB 2.0 4  MASSENBILANZIERUNG EINER  HERA tüv rl cover.qxp  APart CMS608 loudspeaker  Examen de la Charte Internet de l`Etat  Logix 420 IOM - Flowserve Corporation  Kanex KAUXFFMC  4.0 DIAGNOSTICS AND TROUBLESHOOTING  