Home

User Manual - CHAUVET® Lighting

image

Contents

1. Sets the DMX starting address Auto Programs AUTO Sets Auto Program Auto Program Speed Selects Auto Program speed slow to fast Sound Active Mode Set the product in DMX mode to control with a DMX controller 1 Connect the product to a suitable power outlet 2 Turn the product on 3 Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product SNd Sets Sound Active mode When selecting a starting DMX address always consider the number of DMX channels the selected DMX mode uses If you choose a starting address that is too high you could restrict the access to some of the product s channels The Cubix 2 0 uses up to 6 DMX channels in its 6 channel DMX mode which defines the highest configurable address to 507 If you are not familiar with the DMX protocol download the DMX Primer from the CHAUVET website To select the starting address do the following 1 Press lt MENU gt repeatedly until 512 shows on the display 2 Press lt ENTER gt 3 Use lt UP gt or lt DOWN gt to select the starting address 4 Press lt ENTER gt Cubix 2 0 User Manual Rev 1 Page 9 of 13 DMX Channel Assignments and Values 6 CH Channel Function Value Bid 005 028 Red PONES KEKI 169 2 197 197 White Perimeter Effect 000 127 Rotate clockwise slow to fast 3 Motor Rotati j otor Rotation 128 255 Rotate counter clockwise slow to fast 4 Aue NARRA 000
2. Value Innovation Performance Green Thinking TABLE OF CONTENTS Page 2 of 13 T Betore You ESC GUN ni tease clei tl od a 3 WT AYda re al Koll ayes Us o near AA OMEN tren Ste SPR SR Se ven ae gen ee gee 3 LIAB ACKING IASTUCUONS ear ic A 3 A AA AA 3 Text CONVENTIONS 2 a 3 A PN a anal ea 3 BE AA 3 POON Rare Vis PRL Fs aata OE a nee Ee de 4 SAI NOTES A 4 2 INTOQU CUOTA A NAA 5 PLOGUC r OVEN ICW A Ate td AG 5 ROQUE CU SIN ION Srita cca tt itntssio 6 A AA 7 AC POWO A A sng Eba pinal Ga a Tainan paaa NG 7 Fuse Replacement aaa AA iia Ra T POWER estante T MOUNINO A A A A PAA EE E PA E 8 Onen A A A AA EO 8 ale A tere acre te AN 8 4 ODS FAC ON nia 9 Sea te la OPC all AAA e po 9 MENEM AA AA APR 9 CO MIGUPAtOR DNA ma AA baaa 9 E A E IE RENEE 9 DMX Channel Assignments and Values oocoocccccoccccnconcoccocnccncononocanencnnos 10 PAG Habag em E EEE a A A PEO AP aa AE Ors CTE ST ALO Pa 10 Gontiquratio Stand alo ii A AA 10 Automale Mode a ars ea le eo dae do E dd NANG oe 10 SUN AGANE MONG a coc ra io ici 10 Master Slave Mode nasa aaa a id ali 11 5 Technical Informatio M iuris 11 Product Walle ANC scesi a A N 11 o Technical Specifications iia 12 OAC Es OC AA 13 Returning Products to CHAUVET8 aa 13 GRAUVETO Contact Into mano Maala tata 13 Cubix 2 0 User Manual Rev 1 1 BEFORE YOU BEGIN What Is Included Unpacking Instructions Claims Text Conventions Icons e 1x Cu
3. 014 Blackout 3 015 255 Auto Programs 000 015 5 Auto P S d 1009 i Middle Effect uto Program Spee 016 255 oo Ch 4 is from iddle Effec 000 lt gt 015 6 Strobe 016 255 0 30 Hz Configuration Set the product in one of the standalone modes to control without a DMX controller Standalone 1 Connect the product to a suitable power outlet 2 Turn the product on connected to a DMX controller Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller O Never connect a product that is operating in any standalone mode to a DMX string Automatic Mode To enable the Automatic Mode follow the instructions below 1 Press lt MENU gt repeatedly until AUTO shows on the display 2 Press lt ENTER gt Sound Active To enable the Sound Active mode do the following Mode 1 Press lt MENU repeatedly until SNd shows on the display 2 Press lt ENTER gt 3 Turn the music on and adjust the sound sensitivity knob until the product starts responding to the beat of the music Page 10 of 13 Cubix 2 0 User Manual Rev 1 Master Slave The Master Slave mode allows a single Cubix 2 0 unit the master to control the Mode actions of one or more Cubix 2 0 units the slaves without the need of a DMX controller The master unit will be set to operate in either Automatic or Sound Active mode while the slave units will be set to operate in Slave Mode Once set and
4. Code Cubix 2 0 03050528 UL 1573 CSAC22 2 No 166 C US E113093 Page 12 of 13 11 6 in 296 mm Weight 8 1 lbs 3 7 kg Voltage Selection Auto ranging 230 V 50 Hz 48 W 0 2 A 8 A 32 units F1A 250V UK Europe IEC IEC Local plug Lifespan 50 000 hours Current 20 mA 20 mA 20 mA 500 mA 500 mA 500 mA Channel Range 6 Item Number CUBIX2 0 Cubix 2 0 User Manual Rev 1 Contact In case you need to return a product or request support follow the procedure below Procedure If you live in the U S contact CHAUVET World Headquarters see below e If you live in the UK or Ireland contact CHAUVET Europe Ltd see below e If you live in any other country DO NOT contact CHAUVET Instead contact your distributor of record See www chauvetlighting com for distributors outside the U S United Kingdom or Ireland If you live outside the U S United Kingdom or Ireland contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our website for contact details 4 Returning Products to CHAUVET Call the corresponding CHAUVET Tech Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return You must send the merchandise prepaid in its original box and with its original pac
5. connected the slave units will operate in unison with the master unit Configure the units as indicated below Slave units 1 Press lt MENU gt repeatedly until 512 shows on the display 2 Press lt ENTER gt to accept 3 Set the DMX address to 001 4 Connect the DMX input of the first slave unit to the DMX output of the master unit 5 Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit 6 Finish setting and connecting all the slave units Master unit 1 Set the master unit to operate in either Automatic or Sound mode 2 Make the master unit the first unit in the daisy chain e Configure all the slave units before connecting the master unit to the daisy chain e Never connect a DMX controller to a DMX string configured for Master Slave operation because the controller may interfere with the signals from the master unit e Do not connect more than 31 slave units to the master unit 5 TECHNICAL INFORMATION Product Dust build up reduces light output performance and can cause overheating This can lead 3 to reduction of the light source s life and or mechanical wear To maintain optimum Maintenance performance and minimize wear you should clean your lighting products at least twice a month However be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency To clean the product follow the instructions below e Unplug
6. the product from power e Wait until the product is cold e Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents e Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol e Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue e Softly drag any dirt or grime to the outside of the transparent surface e Gently polish the transparent surfaces until they are free of haze and lint O Always dry the transparent surfaces carefully after cleaning them Cubix 2 0 User Manual Rev 1 Page 11 of 13 6 TECHNICAL SPECIFICATIONS Dimensions and Length Width Height Weight 10 5 in 267 mm 12 in 305 mm Note Dimensions in inches rounded to the nearest decimal digit Power Power Supply Type Switching internal Range 100 240 V 50 60 Hz Parameter 120 V 60 Hz Consumption 50 W Operating 0 4 A Power linking current units 8 A 19 units Fuse F1A 250V Power I O US Worldwide Power input connector IEC Power output connector Edison Power Cord plug Edison US Light Source Type Power LED 9W Color Quantity Red 5 mm 32 Green 5 mm 20 Blue 5 mm 12 Red 3 W 2 Green 3 W 2 Blue 3 W 2 Photo Optic Parameter Coverage angle 111 Thermal Maximum External Temp Cooling System 104 F 40 C Convection DMX I O Connectors Connector Type 3 pin XLR Sockets Ordering Product Name Item
7. bix 2 0 e 1x Power Cord e 1x Warranty Card e 1x Quick Reference Guide Immediately upon receipt carefully unpack the product and check the container to make sure you have received all the parts indicated above in good condition If the container or the material inside the container the product and included accessories appear damaged from shipping or show signs of mishandling upon receipt notify the carrier immediately not CHAUVET Failure to do so in a timely manner may invalidate your claim with the carrier In addition keep the container and all the packing material for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a claim with CHAUVET within 7 days of receiving the merchandise Convention 1 512 50 60 Settings Menu gt Settings lt ENTER gt ON Icon IB Meaning A range of values A set of values of which only one can be chosen A menu option not to be modified A sequence of menu options to be followed A key to be pressed on the product s control panel A value to be entered or selected Meaning Critical installation configuration or operation information Failure to comply with this information may render the product partially or completely inoperative cause damage to the product or cause harm to the user Important installation or configuration information Failure to comply with this information may prevent the produ
8. by pulling or tugging on the cord If mounting the product overhead always secure to a fastening device using a safety cable Make sure there are no flammable materials close to the product when operating Do not touch the product s housing when operating because it may be very hot Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the product s housing are blocked Never connect the product to a dimmer Make sure to replace the fuse with another of the same type and rating Never carry the product from the power cord or any moving part Always use the hanging mounting bracket or the handles The maximum ambient temperature Ta is 104 F 40 C Do not operate the product at higher temperatures In the event of a serious operating problem stop using the product immediately Never try to repair the product Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Keep this User Manual for future consultation If you sell the product to another user be sure that they als
9. ct from functioning correctly Useful information Disclaimer The information and specifications contained in this document are subject to change without notice CHAUVET assumes no responsibility or liability for any errors or omissions that may appear in this manual CHAUVET reserves the right to update the existing document or to create a new document to correct any errors or omissions You can download the latest version of this document from www chauvetlighting com Copyright 2012 CHAUVET All rights reserved Electronically published by CHAUVET in the United States of America Author A Diaz Cubix 2 0 User Manual Rev 1 9 16 12 S Graham 9 16 12 Page 3 of 13 Product ata Glance Safety Notes Page 4 of 13 A Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto Programs V Autoranging Power Suppiy v Replaceable Fuse 7 O User Serviceable Duty Cycle OQ Please read the following Safety Notes carefully before working with the product The Notes include important safety information about installation usage and maintenance Always connect the product to a grounded circuit to avoid the risk of electrocution Always disconnect the product from the power source before cleaning or replacing the fuse Avoid direct eye exposure to the light source while the product is on Make sure the power cord is not crimped or damaged Never disconnect the product from power cord
10. e with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Installed fuse held by plastic clip Safety cap Spare fuse holder inside safety cap Power Linking The product provides power linking via the Edison outlet located in the back of the unit Please see the diagram below for further explanation Power Linking Diagram Other products units on 230 VAC The power linking diagram corresponds to the North American version of the product ONLY If using the product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may O You can power link up to 19 Cubix 2 0 units on 120 VAC or up to 32 Cubix 2 0 differ in your country or region Cubix 2 0 User Manual Rev 1 Page 7 of 13 Mounti ng Before mounting the product read and follow the safety recommendations indicated in the Safety Notes Orientation The Cubix 2 0 may be mounted in any position however make sure adequate ventilation is provided around the product Rigging Mounting Diagram Page 8 of 13 Before deciding on a location for the product always make sure there is easy access to the product for maintenance and programming purposes Make sure that the structure onto which you are mounting the product can support the product s weight Please see the Technical Specifications section of this manual fo
11. king and accessories CHAUVET will not issue call tags Clearly label the package with the RMA number CHAUVET will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box 4 Before sending the product clearly write the following information on a piece of paper and place it inside the box e Your name e Your address e Your phone number e The RMA number e A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace returned product s E CHAUVET World Headquarters United Kingdom amp Ireland CHAUVET CHAUVET Europe Ltd Contact General Information General Information Address 5200 NW 108th Avenue Address Unit 1C Information Sunrise FL 33351 Brookhill Road Industrial Estate Voice 954 929 1115 Pinxton Nottingham UK Fax 954 929 5560 NG16 6NT Toll free 800 762 1084 Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Technical Support Voice 954 929 1115 Press 4 Email uktech chauvetlighting com Fax 954 756 8015 Email tech chauvetlighting com World Wide Web www chauvetlighting com Cubix 2 0 User Manual Rev 1 Wo
12. o receive this document Cubix 2 0 User Manual Rev 1 2 INTRODUCTION Product Overview LED Display Fuse Holder Safety Loop DMX In Out Power In Out Mi Aira a a NA NAIN Salala maa Cubix 2 0 User Manual Rev 1 Page 5 of 13 Product Dimensions 10 5 in 267 mm Ji anf 12in 305 mm Page 6 of 13 11 6 in 296 mm Cubix 2 0 User Manual Rev 1 3 SETUP AC Power The Cubix 2 0 has an auto ranging power supply and it can work with an input voltage range of 100 240 VAC 50 60 Hz To determine the product s power requirements circuit breaker power outlet and wiring use the current value listed on the label affixed to the product s back panel or refer to the product s specifications chart The listed current rating indicates the product s average current draw under normal conditions sure the product has an appropriate electrical ground to avoid the risk of i Always connect the product to a protected circuit circuit breaker or fuse Make electrocution or fire Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch AN Disconnect the product from the power outlet before replacing the fuse Fuse 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder Replacement 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replac
13. r weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When power linking multiple products you must always consider the length of the power linking cable and mount the products close enough for the cable to reach The bracket adjustment knobs allow for directional adjustment when aiming the product to the desired angle Only loosen or tighten the bracket knobs manually Using tools could damage the knobs Mounting Bracket Bracket Adjustment Knob Cubix 2 0 User Manual Rev 1 4 OPERATION Control Panel Operation Menu Map Configuration DMX Starting Address To access the control panel functions use the four buttons located underneath the display Please refer to the Product Overview to see the button locations on the control panel Button Function lt MENU gt Press to find an operation mode or to back out of the current menu option lt UP gt Press to scroll up the list of options or to find a higher value lt DOWN gt Press to scroll down the list of options or to find a lower value lt ENTER gt Press to activate a menu option or a selected value Mode Programming Steps Description DMX Address 512 d_1 d512
14. rld Wide Web www chauvetlighting co uk Page 13 of 13

Download Pdf Manuals

image

Related Search

Related Contents

Lenovo ThinkServer TS430  BG90_Instruction and Installation Manual  Sony LCS-TWAB  → DOSSIER DE SOUSCRIPTION - Clients privés  Manuale - Melchioni Family  Imprimante P420  toro/lawn-boy two stage snowthrower drive systems manual  EA Manual 2.3 - Energy Sentry  Fujitsu PRIMERGY TX150 S4  OPERATOR`S MANUAL MANUEL de L`UTILISATEUR MANUAL del  