Home
Datalogger-10 - DOP Solutions
Contents
1. K planned dataset is composed of measuring points taken at different e EE KR Ee SIR de am locations For each location you can enter a theorerical value and a tolerance s EE A ESS A W i MM ei for the main parameter controlled The location creation must be carried out TJ al KI e I via the software Datalogger 10 sa an On the graph values are represented as a function of location D Wl UI ll i PPP PP ET PF re A theoretical value is the value the operator must measured theoretically e g 50 m3 h The tolerance is the allowable deviation from a theoretical value e g the theoretical value is 50 and if its tolerance is 5 m3 h If the measured value is 52 m3 h then the difference is acceptable VI 2 Create a planned dataset In the Device menu click on Schedule job Datasets planning window appears and the dataset list already created is loaded click on Add a dataset Dataset name re Schedule job r CE Dataset number PC Datasets planning Units N b f S K Number of datasets 1 20 Ze umber 0 Number of measurement locations 1 500 Export dataset measurement locations Planned datasets Data
2. Parameters Configuration panel Add Delete program select DATALOGGER 10 and follow Windows instructions to uninstall the application 3 Launching application The DATALOGGER 10 application can be launched by e Click on icon on your desktop or il e Using Start Programs KIMO instruments and then click on DATALOGGER 10 NN ll Software installation DATALOGGER 10 welcome to the DATALOGGER 10 S etup Wizard This will install DATALOGGER 10 on pour computer Insert CD into CD drive S ENEE The installation auto runs If not use your browser to launch IS TECOMMende at YOU Close oi Omer Calon Deore e 1 1 eg g BE the Setup Datalogger 10 exe file from the installation Click Next to continue or Cancel to exit Setup CD Click on Next or Previous to cancel the installation Click on Close to quit when the installation is finished DATALOGGER 70 ll 1 Communication types e Communication with USB cable 1 Plug USB cable between computer USB port and AMI300 2 Select communication mode if key is not automatically recognized e Wireless communication 1 Plug wireless dongle on computer USB port 2 Enter the instrument serial number select it from product database or you can enter it using keypad YY MM NNNN Year month number Before confirmation set the device into unloading Wireless mode Go to Parameters menu and set Wireless loggage to
3. Stop date 3010 2007 10 58 08 Comments Click on a window appears to change comments Click on OK to validate or Cancel DATALOGGER 70 V 3 Probes and functions Information on this panel are e Probes type used e g Standard hygrometry probe e Serial number of probes e g 7103415 e Software version e Calibration date e g 05 10 2007 e Certificate number e g EMA52756947 e Validity period e g 12 months e Each channel is presented with gt Channel number e g V2 gt Measurement parameter e g Temperature C gt Sensor type e g PT 100 probes V 4 Customer and operator This panel provides information on the operator and customer The icon allows to delete information on the operator and customer The icon allows to open the Operator database management window or the Customerr database database window This windows summarize the customer or operator details sheet You can add the customer or operator profile of a dataset click on profile then click on Add to dataset If you wish to quit without saving click on Cancel to close the window Customer gt Operators file ES Operator database management Contacts list Contact details Name Company Name John M OE KMO E 2 Michael C KIMO Company KIMO 3 Robert K KIMO 4 Monica 5 KIMO 5 AllysonF KIMO 6 E Address Add to dataset Probes and functions
4. Probes and functions R Vane Probe Diameter 70 Serialn 07 10 3415 Soft version 0 00 Calibration date Non available certificate number Non available Validity period Mon available Channel 1 chi Debit L s Airflow with vane probe Channel 2 ch2 Temperature C PT100 temperature Customer and operator Customer and operator Operator Ki 4 Name Company Address Phone number Fax E mail Customer 8 Name Custi Company CUST1 Address Phone number Fax E mail Operator Customers file D F customer database management tre fy L Contacts list Contact details Name Company Name Cust1 OT ous r 2 Cust2 CUST2 Company CUST1 3 Cust3 CUST3 Address Add to dataset DATALOGGER 70 VI Planned dataset Create a planned dataset VI 1 Definitions Continuous dataset 22 00 A continuous dataset can be carried out with a device It is composed of dated 21 00 A 30 00 25 00 measurements The method of measurement will be defined by the user 20 50 m automatic with interval or manual instant or average value These datasets 77 can not be planned via the software Datalogger 10 19 00 15 00 18 50 10 00 On the graph values are represented as a function of time 18 00 Ha wis SU Planned dataset
5. 1112 2 Schedule job This function allows to schedule job in advance See Chapter VI Planned dataset p 20 Ill2 3 Synchronize clock Synchronization Datalogger EM e WI Device clock updated This function allows AMI300 clock synchronization with PC A message appears when the synchronization is completed Ill2 4 Delete memory This function allows to delete all datasets message appears when this operation is completed EE IV Software presentation IV 1 Interface Dataset information Menus p Fie Display Device Dataset Tools Windows IS Tool bar gt Dataset name re en ale all 8 A Overall view Graph and chart Legend and statistics Display settings Legends and Se statistics 8 kal ch1 Pression BE Pa B ch2 Temperature BE C Date hour ch1 Pression BE Pa ch2 Temperature BE C 08 10 2007 09 39 13 120 15 25 00 06 10 2007 09 39 23 120 24 25 05 08 1 0 2007 09 39 33 120 28 25 10 06 1 0 2007 09 39 43 120 47 25 14 08 0 2007 09 39 53 120 49 25 14 08 10 2007 09 40 03 120 52 25 18 Values NAA nnn 94013 120 54 2527 chart DATALOGGER 70 IV 2 Tool bar Open DATALOGGER 10 file Transmit datas The tool bar is composed of icons for quick access to functions which are also available from menus ad Save Schedule job Export datas Open products database Print preview Preferences P
6. Fa Application settings hb Data Data files directory This tab allows to choose the directory where files are d EN saved with 2 choices tie Tr Default directory i Use another directory You can select it with Browse button DATALOGGER 70 Communication tab Y Preferences al Application settings IV4 5 b Communication tab i Communication USB key type used This tab allows to select communication type You must specify the key l e type used if it is not recognized automatically S cable usBiey Communication oO i P Radio frequency USB key Cable USB key Printings or ia Ask for the type of key used for each open communication Radio frequency USB key Tick the box M if you wish to choose the type of key used for each open communication Printings tab ZI Preferences D Application settings This tab allows to customize printing with 2 choices Printings Customization of the logo used in printings Preview Image file IV4 5 c Printings tab Logo customization Look for the logo using Browse button Printing options Allows to print or not the graph background Po Print graph background color gradient IV4 5 d Graph tab SE tab RE es This tab allows to select the default configuration Application settings Three graph
7. IV4 4 Dataset This menu is only accessible when a file is opened Dataset e Modify title Dataset allows to change the file title Modify ttle e Dataset information Dataset Summary window appears See Chapter V p 18 for more information Dire ji Modif dataset name e Modify dataset comments e Modify operator information EE Operator database management window appears See Chapter V A Customer and bk EES operator for more information DEES e Modify customer information Edit measurement locations Customer database management window appears See Chapter V 4 Customer and IS Calculation function operator for more information e Edit measurement locations See p 21 L add a comment e Add a comment Choose comment location using cursor An Annotation window appears enter your text Click on OK to validate or Cancel to delete the comment A symbol appears and if you place the mouse over the comment is displayed To modify the comment click once on the symbol and the Annotation window appears Comments are symbolized by a triangle white if it concerns all channels or according to the channel colour e Function This action allows to add change or delete on measuring points gt operations in customized function or gt mathematical functions in customized function or gt predefined calculation function Functions Add a calculated channel Customized function DS ppr
8. ON Ill 2 Device PC Communication Homepage appears with device information such as name serial number software version r Read device This homepage gives access to Connected device Transmit data Device PC Communication Read device fe Wireless Transmission RF transmission ANT ge A Device to pair Device of the database O New device key in serial number RF pairing Dongle Device AMI300 08 08 0503 e Schedule job F Serial n 08 09 0507 e Synchronize clock e Erase memory Soft version 1 352 KIMO Adjustment date 2503 2005 N certificate 0000 Certificate validity 12 month Schedule job Synchronize clack III2 1 Transmit data I12 1a Selection of datasets to download Click on transmit data A window download device datasets appears This function allows unloading of one several or all datasets to transfer all or a part of datasets Tick datasets required Click on Next r Transmit data e p Download device datasets KG Es Selection of datasets to download Datasets recorded in the instrument Datasets list Dataset summary E Continuous datasets Pee Let VI kimo test 1 VI fl test temp ka Planned datasets Interval 5 sec Number of points 12 Start date 07 08 2008 17 50 39 Stop date 07 08 2008 17 51 34 Probe Vane Probe Diameter 100 Weather
9. be cooled at constant pressure and constant water vapor content in order for saturation to occur It is expressed in degree Celsius Wet temperature Temperature calculated with dry temperature and relative humidity in the air It is expressed in Celsius degree C tw Enthalpy This is the heat change which occurs when 1 mol of substance reacts completely with oxygen to form products at 298K and 1 atm It is expressed in kJ kg Analog conversion Function for converting an analog signal current or voltage to a physical quantity for example a 0 10V input converts to a pressure from 0 to 500 Pa WBGT Wet Bulb Globe Temperature Temperature measured with a black ball thermometer and wet thermometer Indoor or outdoor WBGT index calculation IV4 5 Tools Tools This menu allows to reach Tools e Language Language Language software selection e Operator database management See Manage operator database p 20 e Customer database management Duct types management See Manage customer database see p 20 e Duct types management See chapter V3 2 p21 e Display data files 83 Preferences This function open Data Window showing unloaded datas ext dig e Preferences Application settings window appears See below This function allows newly unloaded dataset settings Customer database management Operator database management Display data files Data tab Zl Preferences 1V4 5 a Data tab
10. brought to current file e Reset file Deletes all added modifications to a file returns to original file format Statistics on all dataset points Statistics on visible area in the zoom only identified in Statistics on all points and on visible area in the zoom File menu Open F Add file CtrlH0 Create planned dataset Close Save Chr Save s Reset file Export data Fage setting Print preview Print Ctrl F CirlHQ Cuil lf DATALOGGER 10 Oo e Export data gt Graph as image available file formats Jpg Bmp Gif or Png gt Table to text Values chart to the Txt file format gt PDF file report You can add dataset summarize graph legends and Statistics and values chart Click on OK to save e Page setting SS This function allows to define paper format orientation and margins before printing vat denn ee e Print preview gne fer document selection window appears you can choose one of 3 settings gt Dataset report sn ra gt Graph and statistics ae gt Values chart Start date eee En ma Before printing document selection window appears e Quit Before quitting application a dialog window appears and asks you if you want save this file IV4 2 Display Toolbar The operator can display or hide the following pannels Ever allier e Tools bar See p9 e Overall view See p
11. conditions module Weather conditions module Weather conditions module Vane Probe Diameter 100 FT 100 temperature probe Allows to tick or tick off Measurement Air velocity with vane probe Atmospheric pressure Relative humidity Temperature PT100 temperature PT100 temperature datasets to be unloaded Select deselect all Dataset summary name starting ending date interval points number Table Channels probes parameters and units DATALOGGER 70 1112 1 b Add customer and operator information This window allows to add customer and operator information such as name address telephone Click on Next See SV4 Operator and customer p 19 if information are missing into database III2 1 c Unloading options 1 To choose destination folder click on browsing 2 Management of existing files Each file name is composed by dataset name with file extension dlg e g KIMOTEST dlg If a dataset have the same name three options are proposed a The new file overwrites the older one WARNING If you choose this option the older file and its data will be deleted b The new file is numbered The name is followed by a number ie KMOTEST1 dlg on 01 23 08 KIMOTEST2 dlg on 15 12 08 and next file will be followed by number 3 c The new name is renamed Operator customer Transmit data iF Operator Download device datasets Add customer and op
12. properties can be changed G Graph Default curves properties i Defaut curves properties Color of curve and line width De Default locations time axis properties e gt H H i i Line width v Shadow V Tick tick off the Grid box if you want display or hide it Communication and select its color fk Default locations time axis properties Default background properties Printings co WO on E Select two colors for color gradient and use axis color HS el AA for the grid Gradient Diagonal I ux Use axis color for grid es Grid predefined color Units tab IV4 5 e Units tab Y Preferences D Application settings This tab allows to select units used for duct sizes z Units mm or Sections sizes Unit used for sections sizes Millimeters mm Communication O Inches in Printings H Graph Units 18 DATALOGGER 70 IV4 6 Windows Windows menu windows Arrange Cascade i Close all TT Tile vertically At least two files shall be opened to access this menu e Arrange This function arranges opened windows according to gt Cascade gt Tile vertically gt Tile horizontally w 1 Test HD200 dlg Tile horizontally e Close all A window appears to save before quitting Click on Yes or No to quit e Navigation between opened fi
13. 12 Legen and Statistics e Legend and statistics See p12 e Display comments See p11 Display comments Device IV4 3 Device e Read device See p6 Device PC communication oe Read device Cup e Schedule job See chapter VI Schedule job p 20 e Open products database This information are updated each time device is connected or dataset is unloaded Schedule job Open products database gt Product name gt Serial number gt Operation type gt Certificate number gt Calibration date gt Warning time define by operator f S gt Validity period of calibration TE Si E If this period is soon expired the line is yellow TT e Gen WM eg If this period has expired the line is red One or several certitcates have expired or will expire soon Please contact KIMO After Sales Service Addr Zone Industrielle BP16 24700 MONTPON France Phone 33 0 1 60 06 69 25 Instruments stock management instruments stock management You can delete a device Select device and click on Delete SE Some information may be modified Select instrument and click on Edit n 08 01 0502 gt Certificate number Adjustment gt Validity period Intervention date gt Warning time Certificate number 124355789 Validity period 12 month Warning time 5 a day s before certificate lapsing Click on Confirm to validate or Cancel D DATALOGGER 10
14. Edit location the Measurement location window opens VI 3 1 If the box Enter parameter of air flow calculation is not ticked Measurement location Enter Measurement location Location name Ke Theoretical value Only if a unit has been selected f Theoretical value ul Tolerance Only if a unit has been selected enn BE then click on OK VI 3 2 If the box Enter parameter of air flow calculation is ticked Click on Edit location then Create a new section to enter change or complete technical datas on ducts entered by the operator You can also display this window with Tools menu D 1 Click on 141 to create a new profile 2 Define duct name Duct types e g VMC Z 200 ED Airflow duct types 3 Define duct type and its details diameter for example They change according to the type se 4 Ducts are proposed circular rectangular Fosses coefficient with a coneflow Orton ct or factor K 4 Save the profile with the icon 5 Close the window Section parameters Description WMC Diam 125 3 New section Circular duct OK factor SR Measurement location Measurement location On Measurement location enter Location nane TE 1 Location name 2 Theoretical value Only if a unit has been selected Tolerance RE 3 Tolerance Only if a unit has been selected ON Ces 4 Select an existing duct or crea
15. INSTRUMENTS louise aexploitation des Pare BETA Ing Software for portable instruments Radio Wireless CO Filaire TT Wired www kimo fr DATALOGGER 10 Minimum system requirements D 1 Minimum configuration required sise D FEINT dE ele IEN D ARC PN 5 Il Software Installation cccccssssssssseesscssssessscessseessseessseesseesssnessseessseenss D I Read EN r r 6 Il 4 Communication Gwpes iii 6 II 2 Device PC communication inner 6 VIP AN 5 T4 LS M A EM MM EN EE 6 1112 1a Selection of datasets to download 6 1112 1b Add customer and operator information 7 lll2 1c Download Ke 4 HA Ko ETG EF EEE EEE EE EE 7 22 SCEE JOD EE 8 2 SENNA HVETE ET EE 8 IV Software presentation sine 8 IV 1 Interface 8 IV 2 Te bar 9 IV 3 Graph and chat inner 9 KG Ce EM NO A A 9 LS 10 EG g 1 01 EEE EE EE a 9 LUE D E E EE ER 10 IV3 2 Customize the NN en ee 10 28 ANN 10 lll3 2b Channel OCICS ER ME den 10 EST ee e d 10 lll3 2d Time axis and location aXisS E 10 1113 2e Theoretical values display 11 MZ Background NNN en 11 NZ AGU COMMON aa ee eee sd a oi 11 NN nn ra E E E EE E 1 1 VET OE EE EEE NE SE na a 12 LV 320 Legend and SAS TS arvesak dad A IV Menus e 12 VEGER UE 12 ND VE RI E 13 VE IT EEN EEE RO TE UE 14 1114 4b Mathematical dr TEE 15 I114 4c Predefined calculation FUNCtION cssssscssssccccccsssssceescccccssscsssssensescsssssesessnnenecess
16. comment click once on the symbol and the Annotation window appears IV3 3 Values chart Point Date Time Values of each channel a Values chart Pohl ch1 TK 1 C ch TK 2 C ch3 TK 3 C ch4 TK 4 C 1 OSM 2007 11 46 52 100 30 104 00 102 20 105 00 2 0810 2007 11 47 22 100 43 104 40 102 13 105 00 3 0810 2007 11 47 52 100 76 104 76 102 23 105 10 4 OSM 0 2007 11 48 22 101 17 104 78 102 52 105 09 5 DS 0 2007 11 48 52 101 56 105 01 102 43 105 18 B 0810 2007 11 49 22 101 54 105 31 102 57 105 16 7 08M 0 2007 11 49 52 101 75 105 37 102 74 105 25 e Point number e Recording date and time e And values of each channel e etc The values chart respectively features in rows IP f p OD L A IA i i IV3 4 Overall view Thanks to Overall view window the operator can display the part of graph visible on the Graph and chart window This zone is represented in blue IV3 5 Legend and statistics Legend and statistics panel allows to view channels store with differents colours For example temperature measured on the channel 3 appears in green If you click on blue square you can display or hide the channel on Graph and chart window If you click on cross standard deviation If you click on or EA you can display or hide the statistics of all channels Display settings you can display or hide statistics of each channel min max averag
17. d click on Save A windows confirms file creation 4 To open datalogger file select it and click on Open NTang DATALOGGER 10 09 08 A We reserve the right to modify the characteristics of our products without notice Confiquration minimum I Minimum system requirements Syst me d exploitation Operating system Port de communication Communication port Lecteur CD CD ROM drive Internet explorer 6 M moire RAM RAM 256 Mo 256 MB Espace disque Free hard disk space ss 125 Mo 125 MB Ins rez le CD d installation Insert CD in your CD ROM Si installation ne se lance pas e Allez dans Poste de travail e Reperez le lecteur CD dans lequel est ins r le DATALOGGER 10 Faites un Clic droit sur le lecteur et cliquez Installation should run automatically sur explorer Be If not proceed manually from your Lancez l application setup exe Windows desktop open start menu Click Laissez vous guider run In radio dialog box enter D or valid CD ROM drive letter Click ok Click on SETUPexe to launch installation Exploitez vos donn es Process your data Follow instructions onfigurez Configure Programmez facilement votre appareil Easy configuration of your instrument ampagne de ditez ais ment un D chargez rapport complet eg 255 to measurement datasets Download for analysis and detailed report printing R cup rez rapidement vos donn es Collect your dataset
18. d which others datasets will be added Dataset parameters This reference dataset must be single with only one file and continuous or planned sorter If the reference file is a continuous dataset it will change into a planned dataset rer nice See below Eer Comments v Cancel Open Explanation To change a continuous dataset into a planned dataset lf a continuous dataset called C1 is composed by 1 parameter e g Air velocity and 3 measuring points this dataset will be changed into a planned dataset with 1 location and its value will be the average of measuring points in our case 2 13 m s Continuous dataset C1 Planned dataset A A m s m s AE 2 13 10 00 10 01 10 02 Time C1 a DATALOGGER 70 Vil 2 Step 2 Points creation Create location allows to add datasets to the reference dataset but conditions must be respected wm KA vw Dataset informations 1 the dataset must be single with one file only 2 with the same device Wee ee E eth ete locaton 1 d Renee ovation 3 with the same probes Location name Date hour hl Pression D ch2 Temperatu 1 Controle Pression 08 10 2007 10 00 23 121 49 25 50 4 and with the same channels Operating mode 1 To create points click on Add a file Select a dataset already downloaded in browser and click on Open 2 Click on Greate file 3 Enter new dataset name an
19. e or Display settings allows to define view properties of statistics Statistics are calculated on each channel and you can choose one of 3 settings DATALOGGER 10 Legend and statistics Overall view Legend et statistics Legend and statistics eh2 TK 2 C 7 Max lt 106 74 gt Mw Min lt 10556 gt hd Avo lt 10615 gt hd StDev lt 0 33 gt S E ch3 TK 3 C 7 Eee Ces Mw Min lt 10480 gt hd Avg lt 10517 gt hd StDev lt 0 18 gt ch4 TK 4 C v e Statistics on all the dataset points Interval between the first and the last points measured Statistics on visible area in the zoom only identified in brackets E g From 08 10 2007 14 29 50 to 08 102007 15 00 10 E e Statistics on all points and on visible area in the zoom noted in E brackets O identified in brackets IV 4 Menus IV4 1 File e Open The operator can access Open a datalogger file window Datasets available are displayed on the left If you want open an another file in a another folder click on other location and look for your file Select your datatset and click on Open e Add a file The operator can add a new dataset to the dataset already opened e Create a planned dataset e Close Close the current file Before closing the file a dialog window appears and asks you if you want save this file e Save and Save as Allows to save modification
20. erator information Name Company Select the form Address Phone number Fax E mail Customer Select the form S A This information vill be added to all selected datasets Name Company a Address Phone number Fax E mail Unloading options r Transmit data D A Files destination folder Manage existing files Download device datasets Download options Downloaded files directory C Documents and Settings All Users Documents KIMO Instruments DATALOGGER 10 DATA a CO Overwrite existing files without asking for confirmation to the user Number new files when an existing file has the same name em Ask for the file name to create if the destination file already exists Click on Finish button to start data transmission No dataset is erased If two files have the same name a windows appears to rename the new file Click on Finish to launch unloading III 2 1 d Downloading A window with unloading progress bar appears The upper bar displays unloading status for one dataset The lower bar displays unloading status for all datasets You can stop the downloading click on Stop button Downloading EEr s Transmit data 4 Download device datasets Data transmission Download progress Dataset download FC do Full download stop DATALOGGER 70
21. les Select the file to be diplayed This menu allows to access e Help Allows to display user manual It is also available at the end of the software installation and from the homepage or by pressing F1 on your keyboard e About Displays software information Help menu D Help E About NN V Dataset information Click on 9 or select dataset information in Dataset This window shows all downloaded datasets displayed in tab format Choose your dataset You can print your dataset by clicking on Print V 1 Device Information on this panel are Device Device type e g AMI300 Gs e Serial number e g 07 09 0127 e Software version se ee S Calibration date Calibration date Mon available e Certificate number N certificate Non available Certificate validity Certificate validity Mon available V 2 Dataset parameters information on this panel are e Dataset name e g TestHD200 Dataset parameters Dataset parameters Dataset name Controle D bit Click on To change name Click on OK to validate or Cancel e Dataset type continuous or planned Point numbers e g 90 Interval between two measurements e g 30 sec e Starting date e g 10 08 2007 13 42 07 e Ending date e g 10 08 2007 14 31 37 e Comments e g RAS Dataset type Planned point numbers 145 Start date 3010 2007 10 55 44
22. n lt expr gt Return the logarithm of lt expr gt lt expr gt must be positive Log10 lt expr gt Geh KEE 0 logarithm of lt expr gt Log V NameChannel1 10 3 V NameChannel2 calculate following formula V NameChannel1 10 3 V NameChannel2 and equals the base 10 logarith lt expr gt must be positive Ceiling lt expr gt Cosinus lt expr gt Pow lt expr gt lt pw gt Potency raising Ex pow 5 3 125 Rounded value of operator to the closest whole number Round 2 4 equals 2 Round 2 6 equals 3 Return the sine of lt expr gt radians Sin 1 5708 equals 1 Sin 3 1416 equals 0 Sort lt expr gt Return the square root of lt expr gt Tangent lt expr gt Return the tangent of lt expr gt radians Tan 0 7854 equals 1 Round lt expr gt Sin lt expr gt Tan 3 1416 equals 0 O DATALOGGER 70 i IV4 4 c Predefined calculation function How to use a predefined calculation function e Check the box Use predefined calculation function e Select function See table below e Select channels corresponding to parameters included in calculation e Select the channel properties Name decimals units are automatically selected e Validate with OK Absolute humidity Is the ratio between mass of water vapor present to mass of dry gas It is expressed in grams of water vapor per kilogramms of dry gas g kg Dew point The temperature to which a given air parcel must
23. nd change its parameters such as units points scale high and low limits i IV3 2 c Scale properties The operator can select the scale to change and define its parameters range marking display IV3 2 d Time axis and location axis e The operator may access to the view properties absolute time representation date and hour or relative representation time interval with start and end date for time axis select between an automatically calculated marking or a user defined one select axis colour and enable disable gridlines display For a planned dataset operator Location axis properties planned dataset may access to select location axis color and enable disable gridlines display ES Graph settings Locations axis properties Display Axis color I Grid PTT BE e LL z 15 Ex 2 ES Graph settings Channels properties Contextual menu Tools Channels properties Scales properties Location axis properties Theoretical values display Background properties Add comment M Channel properties chi m s Bar graph Points ms v Style LU Spacing Scale e Common C Single Limits Color Color Di High limit E Low limit ES Graph settings LF Scale properties ms Max value 2 000 Min value 2 000 Marking Automatic Defined Subdivisions fi ES Graph settings Time axis properties contin
24. ntegral part of result Example 13 3 1 DATALOGGER 10 D IV4 4 b Mathematical functions How to create math function e Create formula Click twice on math function see Table of math function below and click twice on the channel or add appropriated number e Check syntax If syntax is right continue to next step otherwise correct the formula e Select channel properties Name units decimals e Validate with OK abs lt expr gt Return the absolute value of lt expr gt ABSV NameChannel1 calculate absolute value of NameChannel if it is positive or opposite otherwise ABS V NameChannel1 10 3 V NameChannel2 calculate following formula V NameChannel1 10 3 V NameChannel2 and equals its absolute value Acos lt expr gt Return the arc cosine of lt expr gt in radians acos 0 equals 1 5708 acos 1 equals 3 1416 Asin lt expr gt Return the arc sine of lt expr gt in radians asin 1 equals 1 5708 asin 0 equals 3 1416 Return the arc tangent of lt expr gt in radians atan 1 equals 0 7854 atan 0 equals 0 Atan lt expr gt Whole number greater or equal to expression CEIL 2 9 equals 3 CEIL 2 9 equals 2 Return the cosine of lt expr gt radians cos 1 5708 equals 0 cos 3 1416 equals 1 Exp lt expr gt Return the exponential of lt expr gt Floor lt expr gt Whole number smaller or equal to expression Floor 2 9 equals 2 Floor 2 9 equals 3 L
25. rint IV 3 Graph and Chart Display Hide Display Hide Overall view Statistics To select a display type click on one of the 5 icons on the top right of Ed the window E Graph Chart Graph and chart a jal ie Reset graph gl Zoomin Connect points Zoom out Mark points Selection pointer Browsing cursor Forward Zoom Move pointer Hide display 3D curves IV3 1 a Continuous dataset Graph and chart D EIE Toolbar Mek esse lo amp Curves zones Scales Period Time Axis DATALOGGER 70 i IV3 1 b Planned dataset gt 66 00 65 00 Parameter 1 63 00 Parameter 2 62 00 61 00 60 00 Location s V ei Ze SSS Tolerance is 21 75 21 50 Measured values 21 25 21 00 2075 The theoretical 20 50 Value not displayed 2025 4 here is indicated by 20 00 a horizontal line at the centre of tolerance IV3 2 Customize the graph IV3 2 a Contextual menu Accessible by clicking on the right button of your wheel mouse from the display window Tools Channels properties Scales properties Time axis properties continuous dataset Location axis properties planned dataset Theoretical values display planned dataset Background properties Add comment i IV3 2 b Channel properties The operator can select the different available channels a
26. s easily AN WWw kimo fr FABRICANT fe NE Usine et siege social Zone industrielle BP16 24700 MONTPON Tel 05 53 80 85 00 Fax 05 53 80 16 81 kimo kimo fr Export department Boulevard de Beaubourg BP48 Emerainville 77312 MARNE LA VALLEE Tel 33 0 1 60 06 69 25 Fax 33 0 1 60 06 69 29 export kimo fr
27. set parameters Sizes mm dy C Check uncheck all D name Dataset 1 Measurement mode ME Dataset 1 E Measurement mode Direct value k Point duration Planned datasets P SS E Ae E Theoretical value Theoretical values unit None Si ecimals r unit an d decimals C Enter parameters of airflow calculation e Enter parameters Pi Date location Ek ovation of airflow location Akan SECH Type Height Midth coef Theoretic Tolera Add dataset TF ji Location 1 o Add I Delete Load dataset y Lada dataset Edit locations Dupicatedataset ms tan Save dataset IF SES ton order of list Delete dataset Le mmm Wi Close Send planning to the device Steps to follow ST 1 Dataset name 5 Decimals from 0 to 4 2 Measurement mode 6 Tick untick the case enter parameters of air flow calculation instant value point by point average automatic average see Edit location p 21 automatic point by point average 7 Add Delete Edit location see Edit location p 21 3 Point duration Define the duration in seconds if the measurement 8 Click on Send planning to the device mode is the automatic point by point average 9 Save 4 Unit for the theoretical value DATALOGGER 70 VI 3 Edit location If a unit has been selected you can enter a theoretical value for this channel The measured value will be compared to this value To enter or change location details click on location then click on
28. snsesseeeessssnssnsessssensnsaness 16 WES TOOS e 16 RO E DE E NN 16 IV4 5b Communication tab rumrasvrsrrsvravrsnersersnrssersvrssersvrsnersersnersersnrsserserssessersnessersnesnersersnersersrrssersrnssersersnenne 17 VE GT F NUNS AD EE 17 VE EE E EE A RO OURS e EE 17 Ne VV NINO WS NO MEET E GE V Dataset information EE 18 V 1 Deviee e V 2 Dataset parameters inner TO V 3 Probes and functions nn 19 V 4 Customer nd operat r L neruserasqennadsmninmvimmjdaudjnnniseienstedue 19 VI Planned dataset Create a planned datasetj serunnnnnvrnnnnnnvrnnnnnnnvnnnnnnnvnennne 20 VI 1 Definitions inner 20 VI 2 Create a planned dataset ru 20 VI 3 Edit location nn 21 VI 3 1 If the box enter parameters of airflow calculation is not ticked 21 VI 3 2 If the box enter parameters of airflow calculation is ticked 21 VI 4 Load dataset nn 22 VI 5 Duplicate ds vr 22 VI 6 Save EE EE 22 VI 7 Delete dataset nn 22 VII Planned dataset creatiON rmumssrunnnvnnnnnvnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrennnnrenn ee VI 1 Step 1 select a reference file 22 VI 2 Step 2 Point ereation iii 23 DATALOGGER 70 1 Minimum configuration required e Windows 2000 XP and Vista e Communication Port USB and RS 232 e CD drive e Internet Explorer 6 0 e RAM 256 Mo 2 Software uninstallation Using Start
29. te a new duct click on Sectone sort Alsedions Create a new section and the Airflow duct types lese He mes window opens see above Har ewer Grover e ee wem You can classify ducts predefined by type artow contre 5 Select your duct and click on OK to validate Ok tector Create a new section CZ DATALOGGER 70 VI 4 Load dataset This button allows to browse the computer directories and to select a dataset already saved ln Load a dataset Loading will be refused if location number contained is greater than the number of remaining points allowed VI 5 Duplicate dataset You can duplicate a dataset Select the dataset and click on Duplicate dataset Duplicate dataset VI 6 Save dataset After writing the dataset into the device it is recommended to save datasets with this button Save dataset VI 7 Delete dataset You can delete a dataset Select the dataset and click on Delete dataset Delete dataset SN VII Planned dataset creation To access this function click on Create a new planned dataset on the File menu This function allows planned dataset creation from others datasets continuous or planned D Selection of a reference file Jsers Documents KIMO Instruments DATALOGGER 10 on C fi CampPonctuelle dig Device ressio 4 Test HD200 dig MP200 VII 1 Step 1 Select a reference file eter H sws o The reference file is the first dataset selecte
30. uous dataset Automax Max C atomin Min Display color M Grid Re Background properties Displayed period Absolute O Relative Start A082008 15 31 18 Stop 21 08 2008 15 31 37 Marking Automatic Defined vi tastport point Display Coir Wi Grid DATALOGGER 70 Theoretical values display i IV3 2 e Theoretical values display ES Graph settings D e Theoretical values The operator can add theoretical values or tolerance on the y graph and select axis color and filling Theoretical values display C Draw theoretical values Draw tolerances Color Use axis color Choose color Fil Ee Background properties ES Graph settings EZ Background properties This windows allows to change the background and grid AD colors Background color Grid i IV3 2 f Background properties Background color gradient 7 Use axis color Choose color Gradient angle Diagonal Add Comment IV3 2 g Add comment Annotation The operator can insert a comment on the graph Choose comment s e e Common notation or location using cursor window appears and enter your text Click on im Lieun119 _ OK to validate or Cancel to delete the comment symbol appears and Note text max 30 characters Annuler a if you place the mouse over the comment is displayed To change ir
31. ustomized function Use predefined function Predefined function Formula Check syntax Function Parameters of wet air calculation Temperature Parameters of wet air Humidity t H Channel Unit Oper Details C h anne S P chi D bit Ls Addition Bulb globe calculation 1 ch2 Temperature TO Subtraction Multiplication H Division Conversion parameters Operations xP ho Cam Conversion parameters Channel Operations Mathematical functions Function Details abs lt expr gt Absolute value of lt exp gt H H acos lt expr gt Are cosine of lt expr gt in radians Mathematical fu nctio ns asin lt expr gt Are sine of lt expr gt in radians We expr Are tangent of lt expr gt in radians elling lt expr gt Entire number superior or equal to lt expr gt cosinus lt expr gt Cosine of lt expr gt in radians exp lt expr gt Exponential of lt expr gt floor lt expr gt Entire number inferior or equal to lt expr gt Channels properties IV4 4 a Operations How to create an operation e Create the formula Click twice on the channel and click twice on the operator see below operators table Ex 001 008 e Check syntax If syntax is right go to next step otherwise please correct the formula e Select channel properties Name units decimals e Validate with OK Operators table Fe Addition substraction multiplication and division Modulo I
Download Pdf Manuals