1. Only use original parts for any maintenance or repair operation e Do not modify the automation components unless explicitly authorized by the factory e Instruct the product user about the control systems provided and the manual opening operation in case of emergency e Do not allow persons or children to remain in the automation operation area e Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation e The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel e Anything which is not expressly provided for in the present instructions is not allowed e Before installing the gate opener check that all moving part as well as the sliding gate is in good mechanical condition correctly balanced and opens and closes properly e Save these instructions for future use Preparation for Installation Before proceeding to your opener installation check if your gate structure is in accordance with the current standards especially as follows The gate sliding track is linear and horizontal The wheels are suitable for use The gate should be mounted and moved freely Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications table of this document Make sure that the gate is plumb and level The fence posts must be mo
2. ALEKO AC 1300 2400 Please read and follow all warnings precautions and instructions before installation and use Periodic checks of the opener are required to ensure safe operation For residential use only Save this manual REV 13E www WholesaleGateOpener com Table of Contents GENTAN 12 eee ee enna ee eee eee ee eee ees eee ee eee nee ee eee ene eee a eer eee een 2 Preparation TOP INSTA ATION errenneren stanedinekel eietimanenseuiedanesleions 3 PANS TIISN ccscahcuvewtes itive cMenaesdtel gobat veces daoutuueunies suneuiey beset wes winuebabeds E E ed eign nes e E R 4 Optional Accessories Part List czscccasosnecesatihacaedotanvhesgats erecond dices iaded Mondeald on aves dander laud sed eacaeeteeeedss 5 Technical Specifications amp Feature cccccecceccecee cect ee se esc edeeeeeedeussesceecseeeeteeceeteececseueceeceesenscnesss 5 INSTANAUIOIMOV GIVIEW sssrini a iss souluad intact edn dude a a E wie 6 InStallavOnior Thier ODEN ser E NON a a 6 Manual Operation oriee a th a a Cicada ee 7 mstalaton of Chan and chain IOLACK GIS ismeie aeoiee e E OEE E NOE ened 7 Installation of Magnets for Limit SWICNE Siinses a OE E 9 Connecting Of Power Suppl yersan woot weeds oxo e a a i E a a E E Raa R 10 Connecting of the Control Board necucecsscsseaucemseeteencbaseasvarotentedacess ebvetaiendewasaneeecans Bede sa beeeuaanee sant 10 Selling of the Control Board w1ec csccse ned sateategaGucatoubegad aa aaa T aa
3. acket if the roller hit Positive stop in an accident A I see eee eee Parts List Remote Control 2 pcs Release Key 1 pc 2 pcs Magnet bracket 2 pcs Magnet Assembly N pole amp S pole M8 70 Bolt C w Q 4 pcs 10 Lock Washer 8 Lock Washer 6 Lock Washer 12 pcs 20 pcs 4 pcs y a M10x40 Bolt Socket Head Screw 4 pcs M10 Nut 8 pcs M8 Nut 20 pcs M640 4 pcs Optional Accessories Parts List Optional Alarm Lamp Photocell Beam System LM140A 1 set LM102 Mounting post for keypad 1 pc LM107 Wireless Keypad Wall push button 1 pc LM172 1 pc LM147 Technical Specifications amp Features Specifications eS oe 600KGS 1500185 Features Midway mode Quick selection for the gate open close direction Reliable rolling code technology for remote control Emergency release key in case of power failure Stop Reverse in case of obstruction during gate opening closing Built in adjustable auto close Built in motor running limitation max 90 sec Reliable electromagnetism limit for easy adjustment Can be equipped with a wide range accessories Installation Overview Sliding Gate Alarm Lamp __ Magnet S pole Concrete Pad Gate Operator Chain Magnet N pole U Bolt amp Photacell Base Plate L Bracket amp Chain Bolt Installation of the Opener Caution Be sure that the opener is installed in a leve
4. ator in pedestrian mode is 2 seconds DIP Switch 3 Auto close function enabled disabled DIP Switch 3 ON auto close function enabled OFF auto close function disabled ON Right open factory default setting For gate to open toward left and close toward right OFF Left open For gate to open toward right and close toward left 2 Potentiometers Potentiometer A and B are used to adjust the stall force and auto close time of the gate operator separately Turn potentiometer A clockwise to increase the stall force and turn it counter clockwise to decrease the Stall force Turn potentiometer B clockwise to increase the auto close time and turn it counter clockwise to decrease the auto close time the auto close time could be adjusted steplessly from 1 to 99 seconds 12 re a mmlm n ERE otentiometer A Potentiometer B h Y Control Board ei FORCE AUTO CLOS ACPYMJ2A2 2012 05 26 Test the reversing sensitivity For the sake of safety it is very important to test the reversing sensitivity as soon as the control board set is finished The reversing sensitivity adjustment is inverse correlation with stall force adjustment in potentiometer A and B In other word the stall force level is higher the reversing sensitivity level is lower Put an immobile object along the gate path and then operate the gate to strike it during the open and close cycles The gate must reverse as soon as object is s
5. before pour concrete Remember that cable conduits have to pass through the hole in the base plate 3 Pour concrete and before it starts to harden check that it is parallel to the gate leaf and perfectly level 4 The four anchor bolts must be set into the concrete when it is poured make sure the position of anchor bolts was placed according to the position of mounting holes on the base plate before concrete become harden 5 Mount the base plate to the concrete Pad It s only temporary installation Further adjustment will be required when install the chain 6 Mount the chain box to the base plate by using screws and washers don t make the four screws too tight Manual Operation The opener should be put in the manual emergency release position before fitting the rack installing the opener and limit switch The process is as follows 1 Take off the rubber stopple 2 Insert the Release Key provided and turn it in counter clockwise 180 to disengage the clutch between the gear shaft and power output Now the opener is in the manual operation Installation of chain and chain brackets 1 Chain Brackets a 1 Please refer to below chain brackets figure g rat which shows U bolt L bracket and chain bolt Use the U bolts Square or round to attach the chain brackets to gate frame 2 If Both the square bolts and round bolts are not fit for the gate frame use the appropriate bolts to attach the chain brac
6. daa aias 11 Test the reversing sensitivity ccc cccccce cece cece e eee e essen eee eee e eens sees nesses a seat eeeeeeeeaneeaeeensneseessnenenens 13 How to learn or erase the remote ccccccccecce cece eee ee tees sees seen eeeeeeeesateeeseeseaeeeegeeneggnnetegnegs 13 How to use the remote to control the opener cece ccc cce eee ee cece ence enna ee eneeeaeeaeeeeaeeeneeaneeenanes 13 Touple SHOOUNG orriei a eateries ela die iota leat de de sisi eeds 14 MIGNON CE speichern tesa Marleen ya ile ah ieee ee iat dae chau dama eee Ghent me lay ietie a Cuetec 14 Thank you for purchasing our sliding gate opener We are sure that the products will be greatly satisfying as soon as you start to use it The product is supplied with a user s manual which encloses installation and safety precautions These should be read carefully before installation and operation as they provide important information about safety installation operation and maintenance This product complies with the recognized technical standards and safety regulations General Safety A WARNING An incorrect installation or improper use of the product can cause damage to persons animals or properties e Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach e This product was exclusively designed and manufactured for the use specified
7. e connected into the 13 terminal The BLACK wire of the wired keypad should be connected into the 11 terminal The WHITE wire of the wired keypad should be connected into the 13 terminal The BLUE wire of the wired keypad should be connected into the 14 terminal 6 Push Button Optional The push button should be wired to the 13 and 14 terminals The gate operator works alternately by pushing the button open stop close stop open Setting Of the Control Board WARNING Keep away from the gate during you set the gate opener system in case of the unexpected gate moving Carefully adjust the DIP switches to avoid the risk of machine damage and injury or death Always ask the help of professional technician electrician if you have any question 1 DIP Switches The DIP switches are used to set the running time of the motor in pedestrian mode enable disable auto close function of the gate operator and fast change the open close direction which is determined by the position of the gate operator installed 11 cima sin Control Board do ACPYMJ2A2 2012 05 26 DIP Switch 1 2 Running time of the motor in Midway Mode DIP Switch 1 ON 2 Seconds OFF 0 DIP Switch 2 ON 4 Seconds OFF 0 NOTE The midway mode function would be disabled if both DIP switches are turned off Factory default setting is disabled TI O 4 mm ANNIN TTT i Running time of the oper
8. in the present documentation Any other use not specified in this documentation could damage the product and be dangerous e The factory declines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the present documentation e Do not install the product in explosive atmosphere e The factory declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use e Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted e Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm e Make sure a residual current circuit breaker with a 30mA threshold is fitted before the power supply mains e Check that earthing is carried out correctly connect all metal parts for closure doors gates etc and all system components provided with an earth terminal e Fit all the safety devices photocells electric edges etc which are needed to protect the area from any danger caused by squashing conveying and shearing e The factory declines all responsibility with respect to the automation safety and correct operation when other supplier s components are used e
9. kets to gate frame A xf a 2 How to install the chain Oe E l J 7 r4 P U Bolt 2 pes Plain Washer 8 4 pcs Spring Washer 8 4 pcs f Hex Nut M8 4 pcs f 4 Plain Washer 10 2 pcs Spring Washer 10 2 pcs Hex Nut M10 2 pcs 1 Place the chain around the top of the idler wheels and under the drive sprocket in chain box p 2 Connect a chain bolt to one end of chain from Mester Hnk aai i chain box by using master link Then insert the chain bolt to the L bracket and fix them each other by 7 washers and nuts temporarily Nuts will be further adjusted for a proper chain tension later 3 Connect second chain bolt with another end of chain from chain box then attach bolt to the L bracket on opposite end of gate using the washers and nuts 4 Make sure that the chain is line up exactly with the position where the chain on the chain idler wheel 5 Get the desired chain tension by adjusting two chain bolts of the both end Cut the unwanted length of chain if necessary 6 Fix the base plate by tightening the washers and nuts 7 Insert the opener shaft into the drive sprocket of chain box Mount the opener by tightening the bolts and washers 8 Fix the chain box by tightening the four lax screws Chain Bolt N Idler Wheel Master Link Thoroughly fasten the four nuts as well as spring washers onto anchor bolts tightly enabling the
10. l and paralleled position and is properly secured Improper installation could result in property damage severe injury and or death Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailment Ensure that the safety side panels are present Necessary Tools The following tools may be necessary to install the Gate opener You will need screwdrivers an electric drill wire cutters and a wire stripper a socket set and possibly access to a welder When install the opener you should build a concrete pad to support the base plate of opener in order to maintain proper stability The installation proceeds are as follows 1 Dig a hole for a concrete pad which should be approximately 60 x 32 x 35cm 24 x130 x 14 It may protrude 10 cm 4 above ground and 25 cm 10 in depth underground Increase the pad height Gate Opener Pa Hex Bolt M10x40 4 pcs Spring Washer 10 4 pcs Plain Washer 10 4 pcs S is N Socket Head Screw j M6x40 4 pcs Spring Washer 6 4 pcs Plain Washer 6 4 pcs Chain Box P Hex Nut M10 4 pcs Base Plate Spring Washer 1 pc 10 4 pes a Big Plain Washer 10 4 pcs i Anchor Bolt 4 pcs aa Cable if necessary to protect the system from flooding heavy snow etc 2 Prepare one or more conduits for the electrical cables
11. must be installed at left side and the magnet component with S pole outside must be installed at right side from the view inside of property Finally adjust the magnet to the proper position by moving the gate with the motor The magnet should be less than 1 away from the magnetic limit switch If it is too far away the switch will fail to work The distance between the magnet and the opener should be 0 39 0 59 with the opener cover on Adjust the position of the magnet until the positions of the opening and closing meet the requirement Connecting Of Power Supply The power supply cord should be at least 3x0 75mm2 Connect the live wire and neutral wire to the L 2 and N 1 terminal respectively and connect the earth wire to PE Connecting Of the Control Board Wired A LM106 Photocell LM102 Emitter Receiver NC Start Capacitor Alarm Lamp LM140A Limit Switches FORCE l mz Control Board oD A RECEIVERI LLLLLLLLAALL ACPYMJ2A4 1 Motor The BLACK wire of the motor should be connected into the 3 terminal The YELLOW wire of the motor should be connected into the 4 terminal 10 The RED wire of the motor should be connected into the 5 terminal 2 Limit Switches The YELLOW wire of the limit switches should be connected into the 8 terminal The BLACK wire of the limit switches should be connected into the 9 terminal The RED wire of
12. opener is firmly secured on the concrete pad during the whole gate travel 3 Check position of opener and chain brackets 1 The chain brackets must be mounted to the same height as the chain on the idler wheels eh LA Bai EEH 2 The opener must be parallel to the gate 3 Make sure there is 1 distance at least between the chain box and the gate after you position the base plate 1 min Installation of Magnets for Limit Switches Before install limit switch make sure the gate opener is put in manual operation the clutch connected with gear shaft is disengaged and the mains power supply is disconnected Position the two Magnet Components approximately on the gate and move the gate by hand to fix them in place Fit magnets bracket Push the gate fully closed by hand Locate and install the magnet bracket so that the opener will stop at the desired close position when the close limit switch approaches it Push the gate fully open by hand Locate and install the magnet bracket so that the opener will stop at the desired open position when the open limit switch approaches tt 0 15mm Magnet Bracket 2 pes i Magnet Component N pole amp S pole Hex Bolt M870 4 pcs Plain Washer 8 4 pcs Spring Wahser 8 4 pcs Hex Nut M8 4 pcs Gate Opener Chain Box Base Plate The magnet component with N pole outside
13. the Pedestrian Mode function is disabled the operator works alternately open stop close stop open by pressing Key B Troubleshooting Have a multimeter to check voltage and continuity Use caution when checking high voltage terminals Symptom Possible Solution s The remote control does not emit any Check the batteries are exhausted replace them if necessary single 1 Make sure that the power cord is properly plugged into the mains outlet 2 Check the fuse is blown in the control board if necessary identify the The operator doesn t reason for the failure and then replace a new one run 3 Make sure the photocell beam is not blocked if the photocell is used Check the terminal 11 should be shorted with terminal 12 by a jumper wire Please reset this jumper wire if it is loss 1 The selected force is too small to move the gate Turn the Potentiometer clock wise to increase the force 2 Disconnect the gate from the gate operator and check that the gate slides freely without any binding The gate starts but it is immediately stop or reverse Maintenance Every six months check the following items for proper operation of the unit Lubricate shafts and sprockets Keep operator clean at all times Check and tighten anchors bolts Check for loose or corroded wire Ensure the operator is well earthed and correctly terminated Always check the Stop Reverse in case of obstruction function
14. the limit switches should be connected into the 10 terminal 3 Alarm Lamp Optional One wire of the alarm lamp should be connected into the 6 terminal another should be connected into the 7 terminal 4 Start Capacitor The two wires of the start capacitor should be connected into the 4 terminal and 5 terminal 5 Photocell Optional Use a 2 core cable to connect the terminal of the photocell s emitter to the 13 terminal the terminal to the 11 terminal Also the and terminals of the photocell s receiver should be connected to the 13 and 11 terminals in parallel Use another 2 core cable to connect the COM terminal of the receiver to the 13 terminal the NC terminal to the 12 terminal W Ge Ge Ge Go Ge Ge Ge Ge Ge Ge Ge Ge Je Ge Je Ge Ge Ge Ge Ge Ge Ge Je Ge Ge Ge Ge Ge Ge Ge Ge Ge Ge E T TIPS The terminal 12 and 13 on control board should be shorted if the photocell beam system optional does not use A wire jumper has been used for short to terminal 12 and 13 in factory Please check if this wire jumper is missing or keep the photocell in alignment when the gate can open but fails to close W 0 0 D D D D D D D D D D D D D D D D D D D D D D 0 D D D 0 D D O S Go Go 3 Ge Ge Ge 3 WW D D D D D D D D 5 Wired Keypad 24VDC The RED wire of the wired keypad should b
15. truck with it If the gate doesn t reverse please increase the reversing sensitivity by turning the potentiometer A in counter clockwise direction Turning the stall force potentiometer toward to MIN position to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will stop or reverses very easy by itself while there is little obstruction or resistance such as strong wind or heavy snow sometimes Note 2 Always check the gate reversing function every each time of control board set or restart after ower off p MSN1 Nyya7 e 2 How to learn or erase the remote Learn the remote Press and release the learn button the LEARN LED light will be on then press the key in the remote twice in 2 seconds the LEARN LED light will flash for 4 aN seconds Now the remote has been learnt successfully sae a This control board can learn up to six remotes if you want to learn more we recommend that you buy the external receiver LM138 Erase all the remote codes Press and hold the learn button until the LEARN light is off Now all remote codes have been erased a ee FORCE cae ee 5 i REMOTE How to use the remote to control the operator Key A is used to operate the operator to work alternately open stop close stop open When the Pedestrian Mode function is enabled Key B is used to achieve the Pedestrian Mode function open the gate for the pre setting time When
16. unted in concrete The gate does not bind or drag on the ground e The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping e The opening and closing gate stops are positioned A WARNING Remember that control devices are intended to facilitate gate operation but can not solve problems due to any defects or deficiency resulting from failure to carry out correct installation or maintenance Take the product out of its packing and inspect it for damage Should it be damaged contact your dealer Remember to dispose of its components cardboard polystyrene nylon etc according to the Current prescriptions Refer to the following Figures for gate installation Using the post or wall as a stop either directly or indirectly is not recommended so as to protect the post or wall against damaging shock from the sliding gate Vertical View In sake of safety a positive stop must be mounted on the two end of ground track cD fF AU a RO Keep the 3 distance at least between operator and chain n bracket if the roller hit Positive stop in an accident eaueeee enna It is suggestion that there is a 4 10cm distance at least between i 4 minimum the gate edge and the gate wall when the gate is fully open F i La Positive Stop in fully opening position 2 Keep the 3 distance at least between operator and chain 7 g Se C D23 br
17. when performing any maintenance If this function can t be made operable remove this operator from service until the cause of the malfunction is identified and corrected According to Waste of Electrical and Electronic Equipment WEEE directive WEEE should be separately collected and treated If at any time in future you need to dispose of this product please do NOT dispose of this product with household waste Please send this product to WEEE collecting points a where available www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2012 2014 ALEKO All Rights Reserved