Home

Portland Eco

image

Contents

1. EMERSON The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture 4 WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician Please call Emerson technical support at 1 800 654 3545 if you have any questions about installation and operation of this ceiling fan ETL Model No CF965 3 Ceiling Fan Assembly 3 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan mounting plate on the outlet box 3 2 Remove the shipping spacers and the spacer attachment screws from the motor before installation of blade assemblies Figure 1 Discard the spacers and spacer screws 3 3 Mount blade flanges to fan blades using three 10 32 x 1 4 slotted phillips washer head screws supplied Figure 2 Repeat this procedure for other four fan blades and blade flanges 4 WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly
2. 2 knobs supplied Figure 23 a i sii LOCKWASHERS 2 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling KNURLED KNOBS 2 cover is clear of the downrod A WARNING Figures To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling emersonfans com Please contact 1 800 654 3545 for further assistance 15 ETL Model No CF965 6 Installation of Downlight 6 1 Remove the pre installed wire nut from the fan motor assembly white wire Carefully straighten the white wire strands Pair the light kit assembly white wire with the motor assembly white wire and install the previously removed wire nut Figure 24 6 2 Remove the pre installed wire nut from the fan motor assembly black wire Carefully straighten the black wire strands Pair the light kit assembly black wire with the motor assembly black wire and install the previously removed wire nut Figure 24 4 WARNING Check to see that all connections are tight and that no bare wire is visible at the wire connectors 6 3 Remove one of the three 8 32 x 1 1 4 slotted phillips head screws from the light kit cover Figure 25 Retain the screw for future installation Loosen the other two screws several turns 6 4 Carefully tuck all the wires under the light kit assembly prior to installin
3. SETSCREW LOOSENED GREEN GROUND Sx WIRE 4 5 DOWNROD Figure 6 TWO 80 MOTOR LEADS UNTWISTED 4 5 DOWNROD Figure 7 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 3 Ceiling Fan Assembly Continued 3 11 Loosen the two setscrews in the motor coupling Place the 4 5 downrod into the motor coupling aligning the clevis pin holes in the downrod with the holes in the motor coupling Figure 8 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through CLEVIS I the hole near the end of the clevis pin until the curved PIN Ae portion of the hairpin clip snaps around the clevis pin C The hairpin clip must be properly installed to prevent the lt gt clevis pin from working loose MOTOR Pull on the downrod to make sure the clevis pin is properly COUPLING SES 2 installed 4 WARNING It is critical that the clevis pin in the motor coupling is properly installed Failure to verify that the pin is properly lt installed could result in the fan falling Figure 8 3 12 While pulling up on the 4 5 downrod retighten the two 4 5 DOWNROD setscrews previously loosened in the motor coupling to secure the downrod into place Figure 9 NOTE The setscrews must be properly installed as described above or fan wobble could result RETIGHTEN A W
4. We will ship the repaired or the replacement Emerson Ceiling Fan to you at no charge but you are responsible for all costs of removal and reinstallation of your Emerson Ceiling Fan How You Can Receive Warranty Service You must be the original retail purchaser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Service prior to your call please be prepared to provide all model numbers shown on your Emerson Ceiling Fan Once we have processed your return authorization request we will provide you with a postage paid return label which should be affixed to the Emerson Ceiling Fan package you ship to the address listed at the end of this limited warranty The return label will be sent to the mailing address you provide to us by phone What Is Not Covered This limited warranty does not extend to and expressly excludes e The glass globes and light bulbs of your Emerson Ceiling Fan e Loss or dam
5. 3 WIRES o Ta SWITCH COVER DECORATIVE WALL PLATE Figure 33 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 9 Wall Control Installation Continued 3 WAY INSTALLATION i SECOND One fan controlled by two different SW605 wall FAN LIGHT Swans WALL controls See Figures 33 and 34 WALL CONTROL CONTROL PURCHASED SEPARATELY 4 WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring All wiring NEUTRAL must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a i A RECEIVER LOCATED precaution against possible electrical shock WITHIN THE MOTOR HOUSING TRAVELER WIRE Figure 34 9 9 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan SW605 wall control into the outlet box 4 WARNING Do not connect any neutral white wire to this control Incorrect wiring will damage this control 9 10 At all wall box locations remove faceplates and screws from existing controls Pull controls out from wall boxes and determine which wall box contains the hot lead and which wall box contains the load wire Also identify traveler wires which are common to both wall boxes Disconnect wires from existing controls o
6. Comfort Ceiling Fan product Emerson Ceiling Fan and covers the motor and the other components and accessories of the Emerson Ceiling Fan against all defects in workmanship and materials What The Period Of Coverage Is This limited warranty will cover the Emerson Ceiling Fan motor for the expected lifetime of your Emerson Ceiling Fan when operated in accordance with your Owner s Manual or other instructions provided by Emerson to you with the Emerson Ceiling Fan All other components and accessories of the Emerson Ceiling Fan are covered by this limited warranty for a period of one 1 year from its date of original retail purchase ANY IMPLIED WARRANTY INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS AVAILABLE TO YOU UNDER THE LAWS OF YOUR STATE OR PROVINCE SHALL COVER THE MOTOR FOR THE EXPECTED LIFETIME OF THE MOTOR SUBJECT TO PROPER USE AND FOR ONE YEAR WITH RESPECT TO COMPONENTS AND ACCESSORIES No Other Express or Implied Warranty Applies THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR EMERSON CEILING FAN AND ARE IN LIEU OF ALL OTHER WARRANTIES WRITTEN OR ORAL EXPRESS OR IMPLIED WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE WHETHER OR NOT THE PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE EMERSON CEILING FAN HAS BEEN SPECIFICALLY DESIGNED OR MANUFACTURED FOR YOUR USE OR PURPOSE EMERSON HEREBY DISCLAI
7. e ea 65 READ AND SAVE THESE INSTRUCTIONS Safety Instructions 4 WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 1 Read your owner s manual carefully and keep it for future reference 2 Be careful with the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 3 Do not put anything into the fan blades while they are turning Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2014 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mount
8. main power is turned OFF 2 Interchange an adjacent side by side blade pair to redistribute the weight Locate the supplied blade balancing kit and follow the included instructions 4 Lamp will not illuminate Loose electrical connectors The lamp is burnt out Lamp turns on and then turns off 1 Shut off the branch circuit electricity at the fuse box or breaker panel and check the receiver electrical connectors for proper installation 2 Tum the electricity off and replace the lamp with a new 50W maximum lamp 3 The built in circuit breaker is tripping Check that the lamp is 50W maximum CAUTION Turn the lights off before touching halogen lamps they are very hot and can burn your fingers emersonfans com Please contact 1 800 654 3545 for further assistance 27 ETL Model No CF965 16 Repair Parts EMERSON 28 ETL Model No CF965 16 Repair Parts Listing Model Numbers 2 Description CF965BS00 CF965VNB00 Hanger Ball Assembly Consisting of 761655 17 761655 89 Hanger Bracket 1 Hanger Ball 1 4 5 Downrod Assembly 1 Ceiling Canopy 1 764603 BS 764603 VNB Upper Glass Shade 1 764607 OM 764607 OM Motor Coupler Cover 1 764604 BS 764604 VNB Control Receiver DC Motor 1 764087 1 764087 1 Light Kit Cover 1 764615 BS 764615 VNB Light Kit Assembly 1 764682 WW 764682 WW 50W Mini Halogen Base Bulbs 3 Lower Glass Shad
9. marked Acceptable for ANTI ROTATION TAB Fan Support of 22 7 kg 50 Ibs or less and use screws Figure 16 supplied with outlet box Most outlet boxes commonly g used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 16 4 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall emersonfans com Please contact 1 800 654 3545 for further assistance 11 ETL Model No CF965 4 How to Hang Your Ceiling Fan Continued 4 2 NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED Carefully lift the fan and seat the hanger ball FAR EE T ma downrod assembly on the hanger bracket that was just I D attached to the outlet box Figure 17 Z vi Be sure the groove in the ball is engaged with the anti rotation tab on the hanger bracket Figure 17 g HANGER BRACKET HANGER BALL A WARNING y DOWNROD D ASSEMBLY Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard HANGER BALE HANGER BRACKET A WARNING To avoid possible fire or shock do not pinch wires AT HANGER BALL between the hanger ball downrod as
10. problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Part No F40BP74980000 Printed in China Form No BP7498 Revision 150123 01 15 ETL Model No CF965
11. the SW605 wall control s ON OFF switch to ON position Within one minute of flipping the switch to ON push and hold the FAN OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan lights if installed will blink to indicate the SW605 wall control code has been paired with the receiver IMPORTANT Immediately after successful pairing the ceiling fan will automatically begin high speed conditioning of the motor During conditioning the electronic motor control software is calculating speeds for the 2nd through 5th speed settings based on the blades that were installed on the fan EMERSON 24 10 2 The fan will run for approximately 2 minutes in the upward direction then reverse direction to down flow and run an additional 2 minutes When conditioning is complete the fan will come to complete stop IMPORTANT Do not interrupt the conditioning until the fan comes to a complete stop in approximately 5 minutes All functions of the control will be rejected during conditioning 10 3 High speed conditioning is now complete 10 4 lf programming is unsuccessful retry the above instructions after cycling the SW605 wall control ON OFF switch to restart the 1 minute programming time period 10 5 If still unsuccessful shut off the electricity at the fuse box or breaker panel and change the SW605 wall control frequency page 16 After changing the frequency settings repeat instructions
12. to existing control THE MOTOR HOUSING NEUTRAL Figure 32 EMERSON 20 ETL Model No CF965 9 Wall Control Installation Continued 9 3 Before installing the SW605 wall control place the SW605 wall control in OFF mode by pushing ON OFF switch to the OFF position 9 4 Connect one black wire of the SW605 wall control to the hot wire Securely connect wires with wire connectors supplied Figure 33 9 5 Connect one black wire of wall switch to the load black wire in wall box Securely connect wires with wire connector supplied A WARNING Do not connect any neutral white wire to this control Incorrect wiring will damage this control 9 6 Screw the SW605 wall control into wall box using the supplied screws Leave the SW605 wall control in OFF mode until fan installation is completed 4 WARNING Check to see that all connections are tight and that no bare wires are visible at the wire connectors 9 7 The SW605 wall control is supplied with a white ivory and almond color switch covers Choose the finish that best suits your needs and snap the cover onto the SW605 wall control Figure 33 9 8 Install decorator wall plate using the two screws provided with wall plate Leave the SW605 wall control in OFF mode until fan installation is completed Figure 33 21 SCREWS 2 SW605 FAN LIGHT Li A Leu gt D Loa A 205 B TOLO S 95 j
13. would be a 3 conductor 2 wire with ground of following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembling your ceiling fan refer to section on proper method of wiring your fan page 13 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Your Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF 2 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock
14. 1 5 of this section within one minute of restoring the electricity ETL Model No CF965 11 Using Your Ceiling Fan USING YOUR CEILING FAN Figure 36 Your SW605 wall control has full control of your fan and light NOTE Prior to operation of the fan and light from the wall control set the fan speed to HIGH and turn the light ON 11 1 To set the desired fan speed press the button to decrease the speed and the to increase the speed The LED display will light up to indicate the new speed selected 11 2 To turn the downlight on press and release the button The light will turn on at the light intensity previously selected To change the intensity hold the button down The intensity will go up and down while the button is held Release the button at the desired intensity 11 3 To turn the uplight on press and release the button The light will turn on at the light intensity previously selected The intensity will go up and down while the button is held Release the button at the desired intensity 11 4 Your SW605 wall control comes complete with your choice of three wall cover plates ivory white and light almond 11 5 If airflow is desired in the opposite direction press the button on the SW605 wall control The fan must be operating at any speed for the reverse button to function The blades will turn in the opposite direction and reverse the airflow 11 6 Yo
15. ARNING SETSCREWS It is critical that the setscrews are securely tightened Failure to verify that the setscrews are properly installed could result in the fan falling 3 13 f f 4 5 DOWNROD Make sure the grommet is properly installed in the a COUPLING coupling cover then slide the coupling cover on the COVER downrod until it rests on the motor housing Figure 10 etree Be sure the motor coupler cover is oriented correctly Figure 10 EMERSON 8 ETL Model No CF965 3 Ceiling Fan Assembly Continued 3 14 Place the ceiling cover over the downrod Be sure the ceiling cover is oriented correctly Figure 11 3 15 Route the two 80 motor leads through the hanger ball Reinstall the hanger ball Figure 12 on the downrod as follows Position the hanger ball pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball NOTE A loose setscrew could create fan wobble WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling 3 16 The fan comes with black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hange
16. CODE SWITCHES Y OOO CU dnd doll CODE SWITCHES SW605 WALL CONTROL Figure 31 emersonfans com Please contact 1 800 654 3545 for further assistance 19 ETL Model No CF965 9 Wall Control Installation SINGLE POLE INSTALLATION A WARNING CAUTION To reduce the risk of electrical shock Turning off wall switch is not sufficient To avoid possible disconnect the electrical supply circuit before electrical shock be sure electricity is turned off at the installing the fan li iver main fuse or circuit breaker box before wiring All wiring Staing the tan NNE KI OrTOCSIVAE must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a NOTE Make all wiring connections using wire precaution against possible electrical shock connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 9 1 EXISTING x WALL CONTROL Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the BLACK ceiling fan SW605 wall control into the outlet box 9 2 Remove faceplate and screws from existing wall control Pull control out from the wall box Determine the hot wire and the load wire and disconnect these wires from control Figure 32 Do not attempt to disconnect any wires not RECEIVER LOCATED WITHIN already connected
17. MS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR COMPONENTS AND ACCESSORIES AS OF THE EXPIRATION OF THE ONE YEAR WARRANTY PERIOD FOR SUCH COMPONENTS AND ACCESSORIES IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR THE MOTOR PORTION OF THE EMERSON CEILING FAN ARE LIKEWISE DISCLAIMED BY EMERSON AT SUCH TIME THAT THE EXPECTED LIFETIME OF THE EMERSON CEILING FAN UNDER NORMAL USAGE HAS BEEN REACHED EXCLUSIONS OR LIMITATIONS OF IMPLIED WARRANTIES MAY VARY FROM STATE TO STATE AND PROVINCE TO PROVINCE SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU What We Will Do To Correct Problems If during the one 1 year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship or if during the expected lifetime of the Emerson Ceiling Fan when used in accordance with the User Manual or other instructions the motor is defective in materials or workmanship you must contact Emerson during the applicable warranty period If the defect is covered by warranty Emerson will repair or replace the defective motor component or other accessory at no charge to you If repair of the motor component or accessory is not practical or possible within a reasonable time and no replacement Emerson Ceiling Fan can be provided Emerson will refund to you the actual purchase price of your Emerson Ceiling Fan
18. PECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING ANY ECONOMIC LOSS WHETHER RESULTING FROM NONPERFORMANCE USE MISUSE OR INABILITY TO USE THE EMERSON CEILING FAN OR FOR THE NEGLIGENCE OF EMERSON OR AN EMERSON AUTHORIZED DEALER EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION WHETHER BASED IN CONTRACT INFRINGEMENT NEGLIGENCE STRICT LIABILITY OTHER TORT OR OTHERWISE SHALL EMERSON S OR ANY EMERSON AUTHORIZED AGENT S LIABILITY TO YOU OR ANY INDIVIDUAL USING THE EMERSON CEILING FAN EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE EMERSON CEILING FAN The term consequential damages shall include but not be limited to loss of anticipated profits business interruption loss of use or revenue cost of capital or loss or damage to property or equipment How State and Provincial Law Relates To The Warranty Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province emersonfans com Please contact 1 800 654 3545 for further assistance 31 ETL Model No CF965 Sk EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Questions
19. PPLY WHITE NEUTRAL LISTED WIRE CONNECTOR FAN MOTOR WHITE WIRE emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 5 How to Wire Your Ceiling Fan Continued 5 3 Securely connect the fan motor black wire to the supply black hot wire using wire connector supplied Figure 20 SUPPLY BLACK HOT L S ali SYS FAN MOTOR BLACK WIRE LISTED WIRE CONNECTOR Figure 20 5 4 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and position the black lead on the other side of the outlet box Figure 21 WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result Figure 21 EMERSON 14 ETL Model No CF965 5 How to Wire Your Ceiling Fan Continued 5 5 Screw the two threaded studs supplied into the tapped holes in the hanger bracket Figure 22 THREADED STUDS 2 Figure 22 5 6 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 23 5 7 CEILING COVER Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled THREADED STUDS
20. READ AND SAVE THESE INSTRUCTIONS 4 EMERSON PORTLAND 54 Ceiling Fan Owner s Manual Model Numbers CF965BS00 Brushed Steel CF965VNBOO Venetian Bronze Tae 25955 Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 e Espa ol pagina 33 e Francais page 65 Part No F40BP74980000 www emersonfans com Form No BP7498 Revision 150123 ETL Model No CF965 Table of Contents Section Page Safety Instructions LL 2 1 Unpacking Instructions 0 ooooocooooocmomm o o 3 4 2 Electrical Requirements 4 3 Ceiling Fan Assembly LL 5 10 4 How to Hang Your Ceiling Fan 11 12 5 How to Wire Your Ceiling Fan 13 15 6 Installation of Downlight ee eee eee 16 17 7 Optional AL100 Accent Light Installation 18 8 Wall Control Procedures cece ee eee eae 19 9 Wall Control Installation s a eeann aeea 20 23 10 Programming the Receiver Operating Frequency amp High Speed Conditioning of Fan Control 24 Section Page 11 Using Your Ceiling Fan oo 25 12 Maintenance ees 26 T Accessories cirio doi ii 26 14 Instruction to the User ooo 26 15 Trouble Shooting 27 16 Repair Parts 28 29 Ceiling Fan Limited Warranty ooocccccconcccooo 31 Spanisch a da 33 Frenchi E iran
21. age to the motor or any component or accessory caused by normal wear and tear rather than due to defects in materials or workmanship e Loss or damage resulting from conditions beyond our reasonable control including without limitation repairs not made at our factory or authorized service center use of parts or accessories not provided to you as part of this warranty by our factory or authorized service center mishandling unreasonable use misuse abuse modifications or other damage caused by you or a third party to your Emerson Ceiling Fan while not in our possession e Loss or damage resulting from improper installation or other failure to comply with instructions in your Owner s Manual This limited warranty is deemed null and void upon the occurrence of either of the following events e You cease to own the Emerson Ceiling Fan product or e The Emerson Ceiling Fan is moved from its original point of installation This limited warranty is only valid within the 50 United States the District of Columbia and Canada No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Air Comfort Products or Emerson Electric Co Limitation of Liability REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY TO THE EXTENT PERMITTED BY LAW IN NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL S
22. e 1 764618 0M 764618 0M Fan Blade Flanges 5 764611 BS 764611 VNB Fan Blades 5 764613 DM WA 764613 DM WA SW605 Wall Control w Hardware 1 SW605 SW605 Parts Bag Containing 764619 CRM 764619 BLOX Threaded Studs 8 32 x 1 1 4 2 Knurled Knobs 8 32 2 Lockwashers 8 External Tooth 2 Wire Connectors 3 Clevis Pin 1 Hairpin Clip 1 8 32 x 1 25 Slotted Phillips Head Screws spare 1 1 4 20 x 1 2 Slotted Phillips Head Screws w Lockwashers 11 10 32 x 1 4 Slotted Phillips Washer Head Blade Screws 16 Balancing Kit 1 Owner s Manual BP7498 BP7498 CO NI DUI AT O N Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER e NAME OF ITEM e PART DESCRIPTION e MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 emersonfans com Please contact 1 800 654 3545 for further assistance 29 ETL Model No CF965 EMERSON 30 ETL Model No CF965 Emerson Air Comfort Ceiling Fan Limited Warranty What The Limited Warranty Covers This limited warranty is offered by Air Comfort Products division of Emerson Electric Co Emerson we or us located at the address stated below to the original retail purchaser you or your of an Emerson Air
23. e halogen mini halogen base bulbs with bare hands Fingerprints may result in shorter bulb life Remove fingerprints with rubbing alcohol 6 10 Place the glass shade into the opening in the light kit assembly aligning the three flat areas on the top edge of the glass with the three raised dimples on the light kit assembly and turn the glass shade clockwise until it is fully seated Figure 27 NOTE Periodically check that the glass shade is seated fully clockwise in the light kit assembly 17 LIGHT KIT ASSEMBLY x LIGHT KIT FIXTURE SOCKETS 3 50 WATT maximum MINI HALOGEN Figure 26 BASE BULBS 3 GLASS SHADE Figure 27 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 7 Optional AL100 Accent Light Installation CAUTION To reduce the risk of electrical shock disconnect the electrical supply circuit before installing the accent light kit 7 1 Loosen and remove all three pre installed AL100 mounting screws from the upper housing of the motor assembly Figure 28 Retain the screws for re installation WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock 7 2 CAUTION To reduce
24. ed and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA 02 manufactured by Rhine Electric Co Ltd WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade f
25. g the light kit assembly onto the light kit cover 6 5 Install the light kit assembly onto the light kit cover by aligning and engage the radial slots of the light kit with the loosened screw heads on the cover 6 6 Rotate the light kit assembly to engage the two loosened screws 6 7 With the light kit locked into position tighten the two previously loosened screws 6 8 Reinstall the 8 32 x 1 1 4 slotted phillips head screw previously removed into the light kit assembly to complete installation of the light kit EMERSON LIGHT KIT ASSEMBLY BLACK WIRE FAN MOTOR ASSEMBLY BLACK WIRE FAN MOTOR ASSEMBLY WHITE WIRE LIGHT KIT ASSEMBLY WHITE WIRE LIGHT KIT ASSEMBLY Figure 24 NS ROTATE LIGHT KIT ASSEMBLY N CLOCKWISE TO ENGAGE N LIGHT KIT ASSEMBLY 8 32 x 1 1 4 SLOTTED 78 PHILLIPS HEAD SCREWS 3 Figure 25 WARNING To avoid possible fire or shock do not pinch wires between the light kit assembly and the light kit cover Spare 8 32 x 1 1 4 slotted phillips head screw is provided in parts bag if needed ETL Model No CF965 6 Installation of Downlight Continued A WARNING To avoid risk of burns or other injuries turn power off and allow lamp to fully cool before attempting to replace the mini halogen base bulbs 6 9 Screw the three 50 watt maximum mini halogen base bulbs supplied in the light kit fixture sockets Figure 26 NOTE Do not touch th
26. grounded as a precaution against possible electrical shock SPACER ATTACHMENT SCREW SHIPPING SPACER 10 32 x 1 4 SLOTTED PHILLIPS WASHER HEAD SCREW 3 per blade FAN BLADES 5 FAN BLADE FLANGES 5 Figure 2 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 3 Ceiling Fan Assembly Continued 3 4 1 4 20 x 1 2 SLOTTED PHILLIPS HEAD SCREW AND LOCKWASHER Loosely attach one blade flange assembly to the motor 2 per blade flange assembly hub by securing the two 1 4 20 x 1 2 slotted phillips head BLADE FLANGE screws with lockwashers Make sure the screws are NOT ASSEMBLY 5 tightened Figure 3 Repeat this procedure for other four blade flange assemblies 3 5 Once all five blade flange assemblies are secured to the motor hub proceed to tightening all 1 4 20 x 1 2 slotted phillips head screws with lockwashers at this time WARNING To reduce the risk of personal injury do not bend the MOTOR HU blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades 3 6 ER 8 32 x 1 1 4 SLOTTED PHILLIPS HEAD SCREW Remove one 8 32 x 1 1 4 slotted phillips head screw from the lower housing adapter plate reserve for later use Loosen the other two screws to assemble the light kit cover to the lower housing adapter plate Figure 4 3 7 Rotate the light kit cover to e
27. iew illustration below HARDWARE BAG CONTENTS Description Quantity Threaded Studs 8 32 x 1 1 4 2 Knurled Knobs 8 32 Lockwashers External Tooth 8 Wire Connectors Clevis Pin Hairpin Clip 8 32 x 1 25 Slotted Phillips Head Screw spare 1 4 20 x 1 2 Slotted Phillips Head Screws w Lockwashers 10 32 x 1 4 Slotted Phillips Washer Head Blade Screws Blade Balance Kit ZIA e TI o mm oO oO ow oo 2 C Enl k l k l wek NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding 1 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper styrofoam with the bottom of the motor facing up The upper styrofoam serves as a holder for the fan during the first stages of assembly emersonfans com Please contact 1 800 654 3545 for further assistance 3 ETL Model No CF965 1 Unpacking Instructions Continued This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One 1 4 blade screwdriver One stepladder One wire stripper Materials Wiring outlet box and box connectors must be of type required by the local code The minimum wire
28. lange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades NOTE All setscrews must be checked and re tightened where necessary before installation DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use Sk EMERSON ETL Model No CF965 1 Unpacking Instructions WARNING PACKAGE CONTENTS Do not install or use fan if any part is damaged or Description uantit missing Call Toll Free for replacement parts AU de 0 y gt Fan Motor Assembly Ceiling Canopy Upper Glass Shade Motor Coupler Cover Light Kit Cover Light Kit Assembly Lower Glass Shade Fan Blade Flanges Fan Blades Hanger Bracket Hanger Ball 4 5 Downrod Assembly SW605 Wall Control w Hardware 50 Watt Mini Halogen Base Lamps 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded v
29. likely to result in interference to radio and TV reception The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user s authority to operate this equipment This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Sk EMERSON 26 ETL Model No CF965 15 Trouble Shooting WARNING FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN TROUBLE 1 Fan will not start PROBABLE CAUSE Fuse or circuit breaker blown Loose electrical connections to the fan SUGGESTED REMEDY 1 Check main and branch circuit fuses or circuit breakers 2 Check all wire connections on the fan AWARNING Make sure main power is turned OFF 2 Fan sounds noisy Blades are not tightly fastened to the fan Loose screws in fan motor Light fixture connectors are rattling inside the light kit housing adapter 1 Check all blade screws for tightness 2 Check to make sure all screws in fan motor are snug not over tight 3 Reposition the connectors and carefully reassemble the cover A WARNING Make sure main power is turned OFF 3 Fan wobbles excessively Blades are not tightly fastened to the fan Fan blades out of balance 1 Check all blade screws for tightness AWARNING Make sure
30. mage this fan could result in fire shock and personal injury 14 Instruction to the User if device contains a digital device This equipment has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a class B computing device pursuant to FCC Rules In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is
31. ngage the two loosened screws in the two key hole slots Replace the 8 32 x 1 1 4 slotted phillips head screw removed previously and tighten all three screws to secure the light kit cover to the lower housing adapter plate Figure 4 S LOWER HOUSING NOTE Make sure wires are not pinched between light ti PLATE kit cover and the lower housing adapter plate Spare 8 32 x 1 1 4 slotted phillips head screw is provided in parts bag if needed EMERSON 6 ETL Model No CF965 3 Ceiling Fan Assembly Continued 3 8 Carefully turn the partially assembled ceiling fan over and place it on the styrofoam for final preparation Figure 5 NOTE Be extra careful not to bend the ceiling fan blades while turning the fan over onto the styrofoam NOTE If using a longer accessory downrod discard the supplied 4 5 downrod and install the longer downrod sold separately using the following instructions 3 9 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 6 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 3 15 NOTE Do not loosen the screw holding the green ground wire 3 10 Separate untwist and unkink the two 80 motor leads Route the 80 black and white motor leads through the downrod Figure 7 CEILING FAN partially assembled HANGER BALL
32. nly Do not attempt to disconnect any wires not already connected to existing controls 9 11 Before installing the SW605 wall control place the SW605 wall control in OFF mode by pushing ON OFF switch to the OFF position 9 12 Install a SW605 wall control in the wall box containing the hot wire first Connect the black wire of the SW605 wall control to the hot wire Securely connect the wires with wire connectors supplied 9 13 Connect the other black wire of the SW605 wall control to both remaining traveler wires in the wall box and secure with wire connector supplied amp EMERSON 22 ETL Model No CF965 9 Wall Control Installation Continued 3 WAY WIRING DIAGRAM NEW CONSTRUCTION NOTE Retrofit 3 way installations are likely to include two traveler wires between the two wall boxes In new construction only one traveler wire Is required See Figure 35 4 WARNING Check to see that all connections are tight and that no bare wires are visible at the wire connectors 9 14 Screw the SW605 wall control into wall box using the supplied screws Leave the SW605 wall control in OFF mode until fan installation is completed 9 15 The SW605 wall control is supplied with a white ivory and almond color switch covers Choose the finish that best suits your needs and snap the cover onto the SW605 wall control Figure 27 9 16 Next install the other SW605 wall control
33. r ball downrod assembly Figure 13 Cut off excess leads and strip back insulation 1 2 inch from end of leads LAD 4 5 DOWNROD CEILING 4 5 DOWNROD L HANGER BALL Y ea gt SETSCREW gt 6to9 INCHES HANGER BALL DOWNROD ASSEMBLY If installing the Optional AL100 Accent Light Skip to Section 7 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 3 Ceiling Fan Assembly Continued 3 17 Carefully place the upper glass onto the motor housing Figure 14 3 18 Rotate the four lower housing clamps over the inner edge of the upper glass RUBBER PAD AND CLAMP 4 LOWER HOUSING SCREWS 4 Be sure to keep the rubber pad beneath each clamp to ensure proper clamping Tighten the four lower housing screws to secure the assembly Figure 14 Figure 14 EMERSON 10 ETL Model No CF965 4 How to Hang Your Ceiling Fan A WARNING CEILING The fan must be hung with at least 7 of clearance from floor to blades Figure 15 Y FLOOR Figure 15 4 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7 kg 50 Ibs or less TP z OUTLET a WARNING SUPPLIED WITH Ah OUTLET BOX To reduce the risk of fire electric shock or personal HANGER BRACKET injury mount fan to outlet box
34. sembly and hanger GROOVE bracket ANTI ROTATION TAB Figure 17 EMERSON 12 ETL Model No CF965 5 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation 5 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied Figure 18 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 5 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 19 13 GROUND CONDUCTOR SUPPLY LISTED WIRE CONNECTOR GREEN WIRE GROUND FROM HANGER BALL GREEN WIRE GROUND FROM HANGER BRACKET Figure 18 Figure 19 SU
35. sold separately into the wall box containing the load wire Connect the black wire of the SW605 wall control to the traveler wire s already connected to the black wire in the other wall box Secure with wire connectors supplied 9 17 Connect one black wire of the SW605 wall control to the load black wire and secure with wire connector supplied 9 18 Connect one black wire of the SW605 wall control to both remaining traveler wires in the wall box and secure with wire connector supplied 23 STANDARD WIRING FOR EXISTING 3 WAY CONTROLS B EXISTING WALL CONTROL HOT BLK U TRAVELER WIRES 3 WAY WIRING DIAGRAM RETROFIT fa BLK FAN LIGHT WALL CONTROL SECOND SW605 WALL CONTROL PURCHASED SEPARATELY TRAVELER CONTROL WIRES Figure 35 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 10 Programming the Receiver Operating Frequency amp High Speed Conditioning of Fan Control Important Read This Section Carefully and Follow the High Speed Conditioning Instructions Closely PROGRAMMING THE RECEIVER OPERATING FREQUENCY amp HIGH SPEED CONDITIONING OF FAN CONTROL IMPORTANT Ceiling fan blades MUST be installed before high speed conditioning can begin 10 1 Turn the wall control ON OFF switch to the OFF position Restore electricity to the ceiling fan branch circuit at the circuit breaker or fuse box Flip
36. t be set in one of 32 possible code combinations Figure 31 The five levers numbered 1 2 3 4 and 5 on the switches are factory set in the ON up position Change the switch settings as follows NOTE Do not duplicate the code of an existing control of an installed ceiling fan within 100 feet 8 3 Slide the five switch levers in the SW605 wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 8 4 The sixth switch marked ON and is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to for no dimming of the lights such as for fluorescent bulbs and non dimming CFLs 8 5 Preset Memory Feature Your Emerson ceiling fan light control is equipped with a preset memory feature When the electricity supply to the fan is switched OFF the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF Code switches in the transmitter may be set in 32 different positions If your fan and light turn on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the code switches in your transmitter per the instructions of Section 10 SW605 WALL CONTROL
37. the risk of electric shock disconnect the electrical supply circuit to the fan before installing light kit assembly Position the AL100 accent light so that the opening of the AL100 accent light slides through the downrod Align the mounting holes of the AL100 accent light to the motor assembly Figure 29 NOTE Be sure the AL100 accent light connector is located close to the motor assembly connector for ease of installation Install the AL100 accent light to the motor assembly using three AL100 accent light mounting screws previously removed on Step 7 1 7 3 Securely connect the AL100 accent light connector to the motor assembly connector Figure 30 Screw the four 25 watt candelabra base bulbs into the AL100 accent light sockets Figure 30 Return to Section 3 17 and complete the remaining installation instructions EMERSON LOWER HOUSING SCREWS 4 SS de III LOWER HOUSING SCREWS 4 FAN MOTOR ACCENT LIGHT CONNECTOR Figure 29 y 25 WATT CANDELABRA BASE BULBS 4 LIGHT KIT 8 FAN MOTOR ACCENT LIGHT CONNECTORS ETL Model No CF965 8 Wall Control Procedures 8 1 Your Emerson Ceiling Fan Light Control consists of SW605 wall mounted transmitter and a receiver located inside the motor assembly The control is designed to remotely operate your ceiling fan speed light intensity and direction of rotation 8 2 Your SW605 wall control has code switches which mus
38. ur fan is now wired to be turned on and off from the fan switch A WARNING Fan installation must be completed including the installation of the fan blades before testing the SW605 wall control POWER INDICATOR LIGHT FAN DIRECTION FAN OFF BUTTON Figure 36 25 LIGHT BUTTON HIGH TO LOW SPEED BUTTONS ON OFF SWITCH OFF emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF965 12 Maintenance IMPORTANT CARE INSTRUCTIONS amp WARNING for your Ceiling Fan Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 13 Accessories Ceiling Fan Light Controls see store or catalog 4 WARNING Downrod Extension Kits see store or catalog This product is designed to use only those parts supplied with this product and or any accessories designated 2 specifically for use with this product by Emerson Electric Ah WARNING Co Substitution of parts or accessories not designated ca for use with this product by Emerson Electric Co could The use of any other control not specifically approved for result in personal injury or property da

Download Pdf Manuals

image

Related Search

Related Contents

manual - Scubastore  Instruction Manual BS Series  User`s Manual for ME1AD8HAI-Q  TV One Task  0527  Atdec VF-AT-W/TAA flat panel wall mount  953 05 Rev0 UM PORTA RETRATO DIGITAL 2  COMPUTO METRICO    

Copyright © All rights reserved.
Failed to retrieve file