Home
User Manual
Contents
1. T Ethernet IEEE 802 3u 100Base TX Fast Ethernet IEEE 802 3ab 1000Base T Gigabit Ethernet IEEE 802 3z 1000Base X Gigabit Ethernet IEEE802 3x Flow Control and Back Pressure Switch Architecture Back plane Switching Fabric 12Gbps Data Processing Store and Forward Flow Control IEEE 802 3x Flow Control and Back Pressure Jumbo Frame 9KB MAC address Table Size 1K Packet Buffer Size 1Mbits 5 Port Network Connector 4xRJ 45 10 100 1000BaseT X auto negotiation Auto MDI MDI X function Full Half duplex 1x SFP 100 1000M BasexX combo with1x10 100 1000M TX 6 Port 4xRJ 45 10 100 1000BaseT X auto negotiation Auto MDI MDI X function Full Half duplex 1x SFP 100 1000M BaseX combo with1x10 100 1000M TX 1x SFP 100 1000M Basex Network Cable UTP STP above Cat 5e Cable EIA TIA 568 100 ohm 100m Fiber Cable Multi mode 50 125um 62 5 125um Fiber Cable Single mode 9 125um Protocol CSMA CD LED PW1 Power 1 Green PW2 Power 2 Green ERR Fault Amber TX RJ 45 port LNK Link Active Green SPD Speed 10 100 OFF 1000 Green SFP Fiber Per port Link Green Active Flash DIP Switch DIP 1 OFF Port 5 SFP DEFAULT ON Port 5 TX DIP 2 OFF SFP 1000M DEFAULT ON SFP 100M Reserve polarity protection Present Overload current Present protection Power Supply Redundant Dual DC 9V 56V Power Input Power Consum
2. User Manual Industrial Gigabit 5 6 Port Ethernet Switch v1 0 FCC MARKING This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE the essential protection requirement of Council Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility Company has an on going policy of upgrading its products and it may be possible that information in this document is not up to date Please check with you
3. ption 9 6W 12 24 48 VDC full load Alarm Relay Contact Relay outputs with current carrying capacity of 1A 24VDC Relay in short circuit mode when 2 powers are connected in open circuit mode when only one power supply is connected Removable Terminal Block Provide 2 Redundant power Alarm relay contact 6 Pin Wire range 0 34mm 2 to 2 5mm42 Solid wire AWG 12 24 14 22 Stranded wire AWG 12 24 14 22 Torque 5lb In O 5Nm 0 56Nm Wire Strip length 7 8mm Operating Temperature 40 C 75 C fully tested Operating Humidity 5 to 95 Non condensing Storage Temperature 40 C 85 C MTBF mean time between failure 510 304 hrs MIL HDBK 217F at 25 C Housing Rugged Metal IP30 Protection Case Dimension L x W x D 142mmx43mmx105mm LxWxD Installation mounting DIN Rail mounting and Wall Mounting Certifications EMC EMS EMI EN 50155 EN 60068 2 6 EN 50155 EN 60068 2 27 EN 50155 EN 60068 2 32 CE FCC VCCI FCC Part 15 Subpart B Class A CE EN 55022 Class A Vibration Shock Free Fall
4. r local distributors for the latest information No part of this document can be copied or reproduced in any form without written consent from the company Trademarks All trade names and trademarks are the properties of their respective companies P N 41NE ISG42100 A00 Introduction This rugged designed Industrial Ethernet switch has passed many rigorous environmental test It comes with optional SFP port to extend your network scale to a much larger area With its multi purpose design it can be used for Din Rail or wall mounted It is an ideal unit for IP surveillance traffic monitoring and Security application in critical environment It can tolerate 40 C to 75 C in harsh environment to perform a reliable network Key Features RJ 45 port support Auto MDI MDI X Function SFP port supports 100Base FX and 1000Base X speed Store and Forward Switching Architecture Back plane Switching Fabric 12Gbps 1Mbits Memory Buffer 1K MAC Address Table Power Polarity Reverse Protect With Overload Current Re settable Fuse Provides broadcast storm protection IP 30 Protection DIN Rail and Wall Mount Design Package Contents 1 x Industrial Switch 1 x User Manual 1 x 3 pin Terminal Block 2 x Wall Mounting Bracket and and 4 x Screws 1 x Din Rail Bracket Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service imension Ph
5. s connected Always turn off or disconnect power supply to change dip switch settings Power connection This industrial switch comes with a 6 pin terminal block It can be operated from 9 56VDC power source Always Make sure your input voltage is within this supported voltage range for each model VAAN o iVAVAVAVAVE n WARNING m Any exceeded input voltage will not make this AH OUGULeS unit function and may damage this unit ve vwa T To make power connection Follow the printed polarity for V1 V1 V2 V2 and ground Connect positive wire to V connect negative wire to V also connect neutral wire to the ground screw as shown Relay You may use 24V 1A relay connection to your external device for special purpose When 2 powers are connected the relay is in SHORT mode When any power source fails the relay change to OPEN status Power connecting procedure STEP 1 Pull out 6 pin terminal block STEP 2 Connect wire to V1 V1 or V2 V2 and Ground the neutral wire to the ground screw STEP 3 Plug back 6 pin terminal block to its place WARNING Always ground the power source to maintain a clean power input Due to too many cheap made power supplies it creates too much noise and it will cause the power input fluctuates when connect to this unit To avoid this always ground the power source to gain a clean power input Specification IEEE Standard IEEE 802 3 10Base
6. ysical D E 5 ort O BI a Os zr cocococoocoocococcece LED Indicators For definitions of LED indicators please refer to the following table LED Status Indication PW1 Green when V1 V1 is connected Off Power is off PW2 Green when V2 V2 is connected Off Power is off ERR Amber connect only PW1 or PW2 OFF both PW1 and PW2 are connected LNK Green TX link is detected OFF TX port is not detected Flashing TX port is active SPD Green 1000M speed is detected OFF 10M or 100M speed is detected F5 Green port 5 SFP fiber is detected OFF port 5 SFP fiber is not detected Flashing port 5 SFP fiber is active F6 Green port 6 SFP fiber is detected OFF port 6 SFP fiber is not detected Flashing port 6 SFP fiber is active Dip switch function This unit is equipped with dip switches located on the front panel Adjusting the dip switches will change the default function of this unit This unit has set to manufacturer default as Port 5 SFP and the speed is set to 1000M for both port 5 and port 6 SFP ports you may adjust dip switch setting to select port 5 as TX disable port 5 SFP or set SFP speed to 100M The detail setting as shown below OFF Tie 2 port 5 TX or SFP SFP default Dip 2 to select ON 100M SFP speed OFF 1000M default Warning Dip switch function will not work if it is changed when power i
Download Pdf Manuals
Related Search
Related Contents
Fog Machine Instructions 安全データシート Bosch DVR4C User's Manual IRIS Touch 600 Series Installation Manual GSW 319594-000 User's Manual anew style is coming Remote Controlled Fetch Machine Copyright © All rights reserved.
Failed to retrieve file