IRIS Touch 600 Series Installation Manual

image

Contents

1. Input low threshold 1V Input high threshold 22V Input pull up impedance Internal 10K to 5V supply 16 IRIS Touch 600 series Dialler Installation Manual Maximum operating voltage Maximum current rating 100mA POWER SUPPLY IRIS Touch 600 IRIS Touch 620 IRIS Touch 640 Supply voltage 9 30V DC Typical current consumption Note These figures are based upon Ethernet being connected With GSM GPRS there will also be additional transient peak current of up to 250mA as GSM and GPRS transmissions e g For network registration and calls are made WEIGHTS amp DIMENSIONS IRIS TOUCH 600 Series PCB dimensions 120 x 90mm IRIS Touch 600 Series fully packaged i60 grams weight IRIS Touch 600 Range series Dialler Installation Manual 17 touch Conformance The IRIS Touch range of alarm diallers comply with the following European Directives M 1999 5 EC Radio amp Telecoms Terminal Equipment Directive M 2006 95 EC Low Voltage Directive WM 2004 108 EC Electromagnetic Compatibility Directive Conformance to EN50131 and EN50136 The IRIS Touch diallers are compatible with the requirements of European standards EN50131 1 Alarm Systems Intrusion and hold up systems Part 1 System Requirements dated 2006 and EN50136 1 1 Alarm Systems Alarm transmission systems and equipment January 1998 with Amendment 1 August 2001 as follows B The IRIS Touch diallers conform to Environmental Class Il M The IRIS T
2. The IRIS Touch 600 Series is a PCB format unit intended to be used in the following situations M The alarm panel can communicate with the IRIS card via a serial RS485 interface on the IRIS Touch dialler This includes panels such as Honeywell Galaxy and Texecom Premier M The requirements for alarm signalling is limited to 4 pin inputs for example fire systems or cash machines The range includes the three following diallers B IRIS Touch 600 GPRS B IRIS Touch 620 Ethernet B IRIS Touch 640 Ethernet amp GPRS The IRIS Touch dialler should be located within the alarm panel tamper protected enclosure and powered from the alarm panel battery backed power supply 2 IRIS Touch 600 series Dialler Installation Manual 1 3 System specifications IRIS Touch IRIS Touch IRIS Touch 600 620 640 GPRS Ethernet Ethernet amp Serial data connection for direct connection to alarm panels RS485 data connection for direct v Y connection to alarm panels Alarm transmission and panel d v upload download via serial or RS485 connection Support for SIA 1 3 Contact ID and v v Scancom Fast Format Secure polling monitoring over Ethernet Secure alarm transmission over Ethernet Pin inputs for alarm messages over Ethernet YA v YA Configuration and diagnostic over Ethernet Secure polling monitoring over v GPRS Secure alarm transmission over v GPRS Pin inputs for alarm messages over 4 GPRS Configuration and diagn
3. other device to a reference ground PIN 6 available on the IRIS dialler as shown below Reference ground Pin inputs 1 4 s e o 9 o 9 Opening the contact i e loop is open circuit generates an alarm signal Closing the contact generates the equivalent restore signal 6 IRIS Touch 600 series Dialler Installation Manual touch It is also possible to link the contacts to the IRIS Touch dialler via sense resistors so that an open or short circuit tamper on the loop can be detected and the Monitoring Centre alerted In this case the connections should be made as shown below Reference ground Pin inputs 4K7 Resistor 15K Resistor Note For this feature to work correctly it is essential that the resistors are connected at the contact end of the loop and not the dialler end The Monitoring Centre must also enable the monitoring of this facility on the dialler within the IRIS receiving system 4 1 Installation Use the following procedure to install the IRIS Touch dialler for PIN alarms 1 Install the IRIS Touch dialler inside the existing alarm panel enclosure and fix with the self adhesive feet 2 Plug the Ethernet cable cream between the socket 2 on the IRIS Touch dialler and the local IP router or socket that has been allocated for the IP connection Ethernet versions only Connect the antenna to the PCB 3 GPRS versions only Fit the SIM card 4 GPRS versions only Power must not be applied to the PC
4. reproduced or used except as authorised by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media in which the information may be embedded O 2013 Chiron Security Communications AG
5. 2 Hi oc I 22020209 HHH MR s H eii IBIHHIS 5 HHH LITA La414124 54124 4 1 24 ille 11515125121 BIKINI reses reses dessas ee Hiis HNBINBIBNBBINBIB EE RRR REREN po Hn 3 init H i i ME EIE HEH se p Setet Alarm over IP OUC IRIS Touch 600 Series Installation Manual Version 1 4 Now certifled EN50136 ENS0131 i c im as rA ben U x e We The information contained is supplied without liability for any errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media in which the information may be embedded O 2013 Chiron Security Communications AG touch Contents ls MOT Ove 1 bl AO LS Manual siirre RE 1 V R EEE 2 1 3 System specifications nmnossssssressressrrerrrerrrerrrersererrrrrrrrrr qeu Sea rr ere rean 3 2 PR Eh 4 2 1 Package Contents minosssssssrsssessrressrensrrerrrer dadas rad pa cT noa qa Ru GNU Lama eddie Us 4 22 FEET Ua 4 de 6 1155 0 m 9 4 Installation TOP PIN alarMSs wwwwwwmmwwmamwmamw www mani wwn www namuna coa cat 6 Fl ETON AA m m TT 7 42 Ge 0 EEE oaiae ia riirii 8 4 3 Post configuration tests mssmssssssrsssrrersrrersrresrrresrrerrrorrrrrrrrrnr ren rrrnn ren mimi 8 5 Installati
6. B while the SIM card is being fitted or removed or it may be damaged EM 9 5 Connect the power from the panel s battery backed supply to the IRIS Touch power connection terminals 7 IRIS Touch 600 Range series Dialler Installation Manual 7 touch Check the following M The Ethernet LED is on steady to show that the Ethernet is connected Ethernet versions only The GPRS LED goes steady to show that the GSM is registered GPRS versions only 4 2 Configuration Configuration is performed by using the virtual touch screen within Chiron s IRIS Touch dialler configuration software running on a PC or laptop which is connected to the dialler via the USB interface This screen gives access to the Installation Wizard that guides you through the setup process It is necessary to enter a pin number which is set by default to 111111 It is strongly recommended that this pin number is changed from the default which is an option available in the Settings menu If monitoring of tamper is required this must be enabled on the dialler which can either be done in the nstallation Wizard for all inputs in use or for each input individually in the Settings menu The default SIA messages for each PIN are shown below Fi Ser message Tenore message Weng NBAO1 NBRO 1 Burglary alarm restore NFA02 NFRO2 Fire alarm restore NQA03 NQRO3 Emergency alarm restore NOPO04 NCL04 Open close These can be changed from Dialler Configuratio
7. IRIS dialler Cable lengths up to 100m are allowable Ethernet versions only A SIM card enabled for GPRS with the PIN code clear GPRS versions only The GPRS Access Point Name APN of the SIM card provider Some networks also require a User Name and Password which can also be obtained from the SIM card provider GPRS versions only IRIS Touch 600 series Dialler Installation Manual touch 3 Indicators The IRIS Touch diallers have LED indicators 1 that have the functions described below On when Ethernet connected and synchronized Ethernet versions only Note Flickers off to show each poll SERIAL 0 2s On 0 2s Off to show not communicating with panel 1 5s On 1 5s Off to show dialler not configured 0 1s On 0 9s Off to show normal communication TH Flashes 0 5s On 0 5s off to show dialler operational IRIS Touch 600 Range series Dialler Installation Manual 5 touch 4 Installation for PIN alarms The IRIS Touch dialler has PIN inputs that can be used to generate alarm messages These can be Text messages via SMS GPRS versions only M SIA alarm messages over IP to the Monitoring Centre Fast Format alarm messages over IP to the Monitoring Centre Note These pin alarm inputs can also be used when the dialler is directly connected to an alarm panel via the serial or RS485 connections Each PIN input 5 is designed to be connected in a loop via an open close contact source from an alarm panel or
8. RIS Touch Range Dialler Installation Guide for EN54 21 Compliant Fire Applications e For the installations that must conform to the requirements of the UK specific standards LPS1277 make sure the installation conforms to the requirements set out in Chiron s installation guide IRIS Touch Range Dialler Installation Guide for LPS1277 Compliant Applications IRIS Touch 600 series Dialler Installation Manual 1 touch 1 2 Overview The IRIS Touch range of alarm diallers allows users to migrate intruder alarm systems away from traditional PSTN communications to IP based and or wireless networks without the need to upgrade or replace the alarm system The majority of the intruder alarm systems which are configured to make alarm calls to a central monitoring station use the traditional PSTN analogue network as the communications path However PSTN becomes increasingly unsuitable as users move to IP and Voice over IP VoIP for their fixed networks or rely purely on mobile GSM and GPRS communication In addition most PSTN service providers migrate to VoIP networks so in the not too distant future PSTN lines may be withdrawn The IRIS Touch dialler range is unique in offering a quick and cost effective way to interface any existing alarm system to alternative networks such as GSM Ethernet and GPRS As a result of the flexibility and power of IRIS Touch it has become the IP transmission system of choice for Monitoring Centres across Europe
9. as IRIS IP Module 6 3 Post configuration tests Carry out the usual alarm signaling tests to ensure the Monitoring Centre receives the signals correctly If using GPRS backup disconnect the Ethernet cable and check that the signals are still received correctly 6 4 Alarm panel management The IRIS Touch adapter acts as a conduit for remote configuration of the panel and remote keypad operation using Texecom s Wintex software running with direct IP connection on the PC Incoming and outgoing calls are supported The IP address of the PC running the Wintex software Incoming calls are initiated using the fixed IP address set for the adapter and the port number set on the panel and in Wintex M Outgoing calls are initiated from the IRIS Polling Engine using the IRIS Touch Remote Data Call function IRIS Touch 600 Range series Dialler Installation Manual 19 touch T Relay outputs The IRIS Touch dialler has two relay outputs 10 that can be used in a number of ways M To indicate communications path failure M Activation by incoming SMS Message W Setting by the Monitoring Centre The relay contacts are normally open and closed when activated Wire to these contacts as required and define how they are to be used using the configuration software 16 8 Troubleshooting No LED activity display when Check that there is power to the system IRIS Touch dialler is connected and that the wiring is the correct polarity to
10. is may take a few minutes after power up The Ethernet LED is on steady to show that the Ethernet is connected The GPRS LED goes steady to show that the GSM is registered GPRS versions only 6 2 Configuration Configuration is through the panel keypad under the UDL Digi options menu according to Texecom s instructions If GPRS is used first set the GPRS APN This cannot be done from the Texecom keypad as there is no APN menu entry As an alternative send a text message to the phone number of the SIM card being used The text should be in the format AT G10 apn Where apn is the APN name e g orangeinternet 12 IRIS Touch 600 series Dialler Installation Manual touch Alternatively the information can be set via the virtual touch screen within Chiron s IRIS Touch Dialler Configuration software It is necessary to enter a pin number which is set by default to 111111 It is strongly recommended that this pin number is changed from the default which is an option available in the Settings menu In the Setup Modules sub menu select Setup IP Data and define On Ethernet versions IP address Gateway address and Net Mask of the dialler if fixed IP address used M Port number to be used for communications with Wintex M Polling IP address of the Monitoring Centre Dialler name E Modem speed is set to 19200 In the Com Port Setup sub menu make sure the com port used to connect to the dialler is set
11. n software if required 4 3 Post configuration tests Carry out tests on all the alarm inputs to make sure the Monitoring Centre receives the signals correctly If using GPRS backup disconnect the Ethernet cable and check that the signals are still received correctly 8 IRIS Touch 600 series Dialler Installation Manual Tris touch 5 Installation for use with Galaxy panels 5 1 Installation Use the following procedure to install the IRIS Touch dialler for use with Galaxy panels 1 Install the IRIS Touch dialler inside the existing alarm panel enclosure and fix with the self adhesive feet 2 Plug the Ethernet cable cream between the socket 2 on the IRIS Touch dialler and the local IP router or socket that has been allocated for the IP connection Ethernet versions only Connect the antenna to the PCB 3 GPRS versions only Fit the SIM card 4 GPRS versions only 3 4 amp Power must not be applied to the PCB while the SIM card is being fitted or removed or it may be damaged 5 Connect to the Galaxy bus using either a standard Galaxy jumper cable to the 4 pin header connector 8 or wires to the connector block 7 6 Turn on the power to the panel Check the following M The Serial LED shows Not Configured 1 5s on 1 5s off or Normal 1s on 9s off to confirm that the dialler is communicating with the panel M The Ethernet LED is on steady to show that the Ethernet is connected Ethernet version
12. on for use with Galaxy PaNCIS misnossssssressrersrressrersrrerrrererrrrrnrn enn r narr 9 Sk AA ONT PTT 9 SN ME PN RR 9 5 3 Post configuration tests xii nei tU ciis esreddcnivror d mmende leiet 11 sr BOP FSD OMI E r 11 5 5 Alarm panel management unc aciso cabe cub nien Fee domener 11 6 Installation with Texecom panels cccccccseccsseceeeceeeceeceeseuseneeseeeseeneas 12 M EAN cR 12 b ovnen cn 12 6 3 Post configuration tests uinsssssssssseessressresrsrsrsrnrsrenrrrnrrrrnr ren rrrnrr rn rr rn rn nn 13 6 4 Alarm panel management rarnnrnnnnnnnannnnannnnannnnnernnnernnnennenennensnnenee 13 ks FEN OU UL CERRO UTE 14 8 WIOUDISSHOO BIO waa 14 Appendix A Installation photo screen shots w wwwwwwamwanwwanwanwana wana 15 Appendix B SpecifiCatlOMN sseesressresressresresrrerrrrrrrrrrrrrrrr rer enes rer r nns rar rn rna n ann 16 IRIS Touch 600 series Dialler Installation Manual Tris touch 1 introduction 1 1 About this manual This manual is designed to help you the installer with the installation process for the IRIS Touch alarm dialler We recommend that you read through this manual in its entirety before you visit the customer s site and begin the installation Please note e For the fire alarm installations that must conform to European standard EN54 21 please make sure the installation conforms to the requirements set out in Chiron s installation guide I
13. ostics over v GPRS v 4 2 Relay contact outputs 2 Pin inputs for alarm messages over 4 SMS USB port for local configuration 9 30V DC power from alarm panel YA YA IRIS Touch 600 Range series Dialler Installation Manual 3 touch 2 2 1 Before you start Package contents In this package you should have the following components 2 2 M IRIS Touch dialler PCB with four self adhesive feet M Ethernet cable cream for connection to IP network Ethernet versions only Antenna for GSM GPRS GPRS versions only Installation manual Pre requisites Prior to the installation you must ensure you have the following If the installation is in a residential environment you will need to fit inductors to the input cables of the dialler in order to ensure compliance with EMC Class B emissions requirements Suitable inductors can be obtained from Chiron The IP address for the Monitoring Centre Confirmation that the Monitoring Centre is set up and ready for the account number or name to be used for this IRIS Touch dialler The type of IP address either automatic or fixed for the installation site If the site has a fixed IP address you should get this information from the customer in advance together with the Gateway Address and the Subnet Mask for the IRIS dialler Ethernet versions only An additional long Ethernet CATS cable in case the installation site requires one longer than that supplied with the
14. ouch diallers are compliant to ATS 6 compatible with Security Grade 4 Safety Care should be taken when interconnecting telecommunications equipment that only like interfaces are interconnected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltage between any two accessible parts does not exceed a safe value 42 4V peak or 60V dc maximum The interfaces on the IRIS Touch dialler have the following safety classifications B Data Interface SELV suitable for connection to the SELV interface on a data terminal such as a PC COM port M Power Interface SELV for connection to a DC supply 8 Inputs and Outputs SELV for connection to alarm output and input pins For conformance to the requirements of EN60950 the dialler must be powered from a Limited Power Source as defined in EN60950 The output of the power supply should be fused at 3 0A slow blow 18 IRIS Touch 600 series Dialler Installation Manual The future of security secured IP by security professionals for the professional security industry ae CHIRON Telephone 41 43 508 08 66 Fax 41 43 508 08 73 sales chironsc ch CHIRON SECURITY COMMUNICATIONS AG WORLD TRADE CENTER OFFICE 70 LEUTSCHENBACHSTRASSE 95 8050 ZURICH SWITZERLAND The information contained is supplied without liability for any errors or omissions No part may be
15. s pin number is changed from the default which is an option available in the Settings menu On Ethernet versions for a fixed IP address only set the IP address Subnet Mask and Gateway address on the Galaxy keypad menu 01 Module Configuration The Site Name parameter is not required In the Alarm Report menu 02 set the following M Alarm format required e g SIA entry 1 IP address of Monitoring Centre in Primary IP entry 2 Note that the Port Number is not required M Account number entry 4 M Other menu entries are not used and need not be set Make an Engineer Test call menu 05 The parameters entered will be sent from the panel to the dialler and polling to the Monitoring Centre will start Check that the Poll LED comes on 10 IRIS Touch 600 series Dialler Installation Manual touch 5 3 Post configuration tests Carry out alarm signaling tests to make sure the Monitoring Centre receives the signals correctly If using GPRS backup disconnect the Ethernet cable and check that the signals are still received correctly 5 4 Trouble reporting The IRIS Touch dialler may report the following trouble conditions to the Galaxy panel Line Fail if polling via Ethernet or GPRS is not successful M Fail to communicate if the alarm is not transmitted successfully after ten attempts 5 5 Alarm panel management The IRIS Touch adapter acts as a conduit for remote configuration of the Galaxy panel and remote ke
16. s only The GPRS LED goes steady to show that the GSM is registered GPRS versions only 5 2 Configuration The IRIS Touch dialler can be configured from the Galaxy keypad Note For GPRS it is not possible to configure the settings e g APN from the Galaxy keypad as the Galaxy has no entry method For GPRS versions the APN can be configured via an SMS message from any mobile phone or by running Chiron s IRIS Touch dialler configuration software on a PC or laptop connected to the dialler via the USB interface IRIS Touch 600 Range series Dialler Installation Manual 9 touch The configuration menu on the Galaxy panel for the Ethernet card is found at location 56 Communications entry 4 Ethernet If the IRIS Touch dialler is not set to the defaults default it by clearing the Primary IP address on the Galaxy menu 02 entry 2 Check that the SERIAL LED is showing Not Configured If GPRS is used set the GPRS APN This cannot be done from the Galaxy keypad as there is no APN menu entry As an alternative send a text message to the phone number of the SIM card being used The text should be in the format AT9 6G10 apn Where apn is the APN name e g orangeinternet Alternatively the information can be set via the virtual touch screen within Chiron s IRIS Touch Dialler Configuration software It is necessary to enter a pin number which is set by default to 111111 It is strongly recommended that thi
17. the power Serial LED flash pattern Alarm panel serial RS485 interconnect fault indicates no connection to the panel 14 IRIS Touch 600 series Dialler Installation Manual touch Appendix A Installation photo screen shot 4 pj E 5 6 10 9 10 2 IRIS Touch 600 Range series Dialler Installation Manual 15 touch Appendix B Specification SPECIFICATIONS IRIS Touch 600 IRIS Touch 620 IRIS Touch 640 Polling monitoring of connection amp alarm transmission via Ethernet Polling Monitoring of connection amp P F alarm transmission via GPRS CONTROL PANEL INTERFACE Honeywell Galaxy Classic G2 G3 and dimension Direct serial bus connection V4 00 and above via RS485 Texecom Premier Series V7 6 and above via RS232 Texecom International Series V15 x and above via RS232 Cooper Scantronic I ON Series with optional CT Interface board via RS23 ETHERNET INTERFACE IRIS Touch 620 and IRIS Touch 640 10 Mbps and 100 Mbps 10 100 Base T with auto negotition Standard RJ45 connector for CAT 5 cable Allows for the use of fixed IP address or DHCP GRPS GSM INTERFACE IRIS Touch 600 and IRIS Touch 640 Quad band GSM 850 900 1800 1900 MHz SMA antenna connection IP TCP OUTBOUND ONLY Polling amp Alarms TCP 53165 Upload download Remote Service App TCP 10001 IRIS Touch 600 Series diagnostic amp firmware upgrade TCP 51292 4 PIN INPUTS Maximum input voltage range OV to 24V
18. ypad operation using Honeywell s RSS software running with direct IP connection on the PC Incoming and outgoing calls are supported E Incoming calls from RSS are initiated using the fixed IP address set for the adapter and the default Galaxy port number 10001 M Outgoing calls are initiated from the IRIS Polling Engine using the IRIS Remote Data Call function to the IP address of the PC running the RSS software IRIS Touch 600 Range series Dialler Installation Manual 11 tris touch 6 Installation with Texecom panels 6 1 Installation Use the following procedure to install the IRIS Touch dialler with Texecom panels 1 Install the IRIS Touch dialler inside the existing alarm panel enclosure and fix with the self adhesive feet 2 Plug the Ethernet cable cream between the socket 2 on the IRIS Touch dialler and the local IP router or socket that has been allocated for the IP connection Ethernet versions only Connect the antenna to the PCB 3 GPRS versions only Fit the SIM card 4 GPRS versions only 3 4 amp Power must not be applied to the PCB while the SIM card is being fitted or removed or it may be damaged 5 Connect to a panel serial port bus using a straight through one one jumper cable 6 Turn on the power to the panel Check the following M The Serial LED shows Not Configured 1 5s on 1 5s off or Normal 1s on 9s off to confirm that the dialler is communicating with the panel Th