battery charging guidelines for 6 volt deep cycle batteries
Contents
1. 2 AAA AA AMA AE AE AE AE Ta gt gt Ooo VES INN INS O INIA O S SI 101 ee raeg po ee AAA a A lt po ee E 2 pe E arar AAA ASS E E TOURS AA AAA AA A A SA E AAA po ee poe re Apnea DIIDEdS Hey ploday asinas l9neg S3ALVNS8311 ADYANT
2. are cold e Batteries should be installed in a well vented area to prevent the possible build up of explosive gasses For safety reasons a well sealed battery box vented at its highest point to the outside is required for indoor installation and recommended for outdoor installation of your lead acid batteries Seal entry point of battery cables from inverter into battery box with silicon or duct seal putty e NEVER smoke in the vicinity of a battery or generator e Always verify proper voltage and polarity before connecting batteries e Always connect batteries first then connect the cables to the inverter or controller This will greatly reduce the chance of spark in the vicinity of the batteries e Use insulated tools when working with batteries e Do not short circuit battery cables Fire or explosion can occur e Always recycle old batteries Contact your local recycling centre for proper disposal information EA Energy Alternatives Ltd 5 4217 Glanford Ave Victoria e BC V8Z 4B9 Toll free 1 800 265 8898 Local 250 727 0522 Fax 250 727 2286 www EnergyAlternatives ca sales EnergyAlternatives ca usyo s n yeq noA ehieyooy J19jem pue epos Bulyeq YUM s jids poe uea D jseweyeq JNOA jo 0 J9 EM pajsip AjUO asn jaoueusjulew Ayeyeq Burwood usym sajBBo6B pue sano b Jeam s em y yoo po oe AAA AAA AAA MA ol Pop pp jp jp f me o eg POS IESO ISO IO IESO AE IESO IES IES E ENT _ _ T S T S S _
3. need a larger generator than you might think you do to charge these batteries Voltage and Time Settings In addition to minimum charge rates there are charging voltage settings which are specific to your 6 volt deep cycle battery bank Bulk Charge Voltage is the voltage at which the batteries will receive most of the charging When the battery has reached its bulk voltage level the charge current will slowly decrease as batteries become more charged As a battery becomes more charged it presents more resistance to the flow of current than when discharged hence the rate of amps declines during a charging cycle This part of the charging cycle is called the absorption stage We recommend 30 minutes of absorption time per 100 amp hours of battery bank rated capacity 20 hour rate All batteries will self discharge over time even if they are not used In stand by applications where utility power is available batteries are often finish charged at float voltage This is the voltage level which can be applied to the batteries to maintain their charged state and at the same time minimize loss of electrolyte In generator cycle charging applications it is rare to float the batteries as it represents a costly and inefficient use of fuel Regular equalization charging is required as part of a battery maintenance routine Daily battery drain down will require a monthly equalization for optimal performance An equalizatio
4. the problem and by then it s too late Dispose of cloths properly If batteries have not been equalized for a long time or have been severely discharged and left in a state of discharge for an extended period it may take several attempts to achieve a proper equalization charge Repeat this process daily until you are achieving proper EQ voltage EA Energy Alternatives Ltd 5 4217 Glanford Ave Victoria e BC V8Z 4B9 Toll free 1 800 265 8898 Local 250 727 0522 Fax 250 727 2286 www EnergyAlternatives ca sales EnergyAlternatives ca Page 4 of 4 BATTERY SAFETY INFORMATION e Inthe event of exposure to battery electrolyte wash the area with soap and water If acid enters the eyes flood them with running cold water for at least 15 minutes and get immediate medical attention Always wear eye protection such as safety glasses when working with batteries e Remove all loose jewellery before working with batteries e Never work alone Have someone assist you with the installation to be close enough to come to your aid when working with batteries e Always use proper lifting techniques when handling batteries e Always use identical types of batteries Battery life will be compromised when mixing different types or ages of batteries e Batteries are temperature sensitive For optimum performance they should be installed in a stable temperature environment Battery capacity can be reduced substantially when batteries
5. ENERGY ALTERNATIVES BATTERY CHARGING GUIDELINES FOR 6 VOLT DEEP CYCLE BATTERIES Introduction Your 6 volt deep cycle battery set has been specially formulated for long cycle life and has particular voltage and specific gravity characteristics The battery charging set points specified in this guide are for these batteries only and should not be assumed appropriate for other batteries It is far easier to discharge a battery than to recharge it Both the charge and discharge of batteries involve significant inefficiencies As a rule of thumb for each amp hour of power taken out of a battery 1 5 amp hours must be replaced In order to complete the chemical process which recharges a battery the electrolyte must reach 104 F The method used to heat up the electrolyte is the application of charging current amps to a discharged battery If insufficient charge is applied to bring the electrolyte to this temperature the batteries will never fully recharge and over time their capacity will be reduced Minimum Charging Requirements The ideal charging current which would be applied to recharge your battery is 10 of the 20 hour rated capacity of the battery For example a 220 Amp hour battery 220 Amp hour 20 hour rate will require an initial start up rate of 22 amps to be supplied by the selected battery charger A combination of charging sources such as generator PV array can be used to achieve the initial charge In general you
6. n charge is an intentional overcharge which causes rapid bubbling of the electrolyte which in turn helps dislodge sulfation which occurs naturally during normal charge discharge cycling Equalization charge settings involve both voltage and time specifications An equalization charge should last at least 2 hours or the same as the absorption time whichever is larger Many programmable chargers and inverter chargers have provisions for custom voltage current and time settings The table below shows the appropriate voltage settings for Bulk Float and Equalization stages of charging Per Cell 12 Volt 24 Volt 48 Volt Bulk 7 2 14 4 28 8 57 6 Float 6 6 13 2 26 4 52 8 Equalization 7 8 x 2 hours 15 6 x 2 hours 31 2 x 2 hours 62 4 x 2 hours EA Energy Alternatives Ltd 5 4217 Glanford Ave Victoria e BC V8Z 4B9 Toll free 1 800 265 8898 Local 250 727 0522 Fax 250 727 2286 sales EnergyAlternatives ca www EnergyAlternatives ca Page 2 of 4 Specific Gravity The specific gravity of your 6 volt deep cycle battery is another method to check the status of your batteries Take readings every hour during the last part of Absorption Stage when the hydrometer does not rise from your last reading the batteries are fully charged The correct fully charged specific gravity of your 6 volt deep cycle battery is 1 265 will vary dependent on battery age condition and ambient temperature Battery life i
7. ng is not high enough to equalize the batteries for the best performance configure your system as per the guidelines below Each installation may have it s own variables and thus these are a general guideline only Menu 10 Battery charging 12 Volt System 24 Volt System 48 Volt System Set Bulk Volts DC 14 4 28 8 57 6 Set Absorption Time 2 9 hours depending on capacity of battery bank Generally 4 hours Set Float Volts DC 13 2 26 4 52 8 Set EQ Volts DC 15 6 31 2 62 4 2 4 5 hours depending on capacity of battery bank SELES me Generally 2 hours i EA Energy Alternatives Ltd 5 4217 Glanford Ave Victoria e BC V8Z 4B9 Toll free 1 800 265 8898 Local 250 727 0522 Fax 250 727 2286 www EnergyAlternatives ca sales EnergyAlternatives ca Page 3 of 4 Programming a C series C35 C40 C60 Controller for 6V Deep Cycle Batteries The C series controllers unfortunately do not offer the ideal adjustments for some settings We generally don t recommend that the automatic EQ feature be used as it s unlikely you will achieve a proper equalization charge Instead control this manually by depressing the reset switch for 10 seconds Unattended sites are an exception where using the automatic EQ feature can be beneficial Equalization setting on a C series controller allows the voltage to rise 1 Volt above the set bulk voltage adequate for equalization of 12 Volt systems but in 24
8. or 48 volt systems not a true equalization charge The following settings are made via the adjustments accessed by removing the front cover of the C series controller The manual describes this process in detail A digital voltmeter is required to properly calibrate these settings The values for the bulk and float settings can be found on the previous page How to Equalize 6V Deep Cycle Batteries Goggles rubber gloves and a long narrow funnel are recommended for battery equalization Have baking soda on hand to neutralize any spills on ground clothes etc Do not allow baking soda inside the batteries Bring batteries to a full normal charge Test with Hydrometer amp record all cells Ensure electrolyte levels are proper you will add more during the charge cycle Initiate an equalization charge according to your inverter type During the final hour of equalize charge make sure you top up the electrolyte with clean distilled water Ensure no debris enters into the battery Make sure the funnel is clean before using it Battery tops should always be very clean moisture and debris on the top can cause the batteries to self discharge Exercise extreme caution during this process After the EQ charge the tops of the batteries will likely have some mist on them Wipe carefully with a disposable cloth Keep this away from clothes etc Acid on clothes does not necessarily show immediately next morning or next week you realize
9. s directly related to keeping your batteries fully charged Batteries are more resistant to degradation and freezing when they are fully charged Configuring a DR Series Inverter for 6V Deep Cycle Batteries For normal operation the battery type selector should be set to 1 Deep cycle lead acid For an Equalize charge set the battery type selector to Equalize We highly recommend the use of Battery Temperature Sensors BTS which is an option for DR inverters and C series controllers included with SW series inverter This sensor will allow the controller to automatically compensate charge rate according to the temperature of the battery Colder batteries require significantly higher charge rates The BTS should be mounted such that it will give an accurate reading of the battery temperature wedged between 2 batteries below the fluid level of the batteries Programming a SW or PS Series Inverter for 6V Deep Cycle Batteries The SW inverter is configured through the digital menu or on the SWRC remote panel or laptop via SWCA interface Instructions below assume familiarity with the operation of this inverter More detailed instructions are available in the user manual The factory default settings on the SW inverter are not adequate for charging 6V Lead Acid Batteries If the unit is disconnected from the batteries it will lose all settings amp revert to factory defaults The new SW Plus inverter will retain settings The factory EQ setti
Download Pdf Manuals
Related Search
Related Contents
Defining Maintenance Object Options Associated Equipment 73-800 User's Manual HP Compaq L190w QJ621A2 データシート User Manual POC-W181 NM2304B - X 1 - Ingersoll Rand JVC TH-G31 Home Theater System User Manual homélie à Saint-Joseph - Paroisse Saint manuel d`utilisateur(francais) here Copyright © All rights reserved.
Failed to retrieve file