DPoE™ 1GIG ™ Power Patch Panel
Contents
1. ycR s IHP Files IEMTOOLS icons Inetpub Grag C3 Japan Stuff lc javakit C3 javakit old C jdk 2 2 J Linktest Local Stuff mnt jMSOCache Cymspclnt Ee ev v v i v 7 v v F7 Sul hy Network Places File name OS Panduit Element Manager ner Cancel Save as type Another dialog box will prompt a confirmation to export all associated port information as well work area location etc NOTE these are two independent files with unique information Port Information 3 Do you want bo export the associated port information also 38 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Once confirmed another dialog box will appear and require a file name such as Panel A Ports and a desired location to save the file Save Port Information As Save In EM beta Ej export port pem Ei export pem ly Recent Documents Desktop My Documents cr Places Save as type Panduit Element Manager pem Cancel Once the Device and the Port information are saved factory resets firmware downloads or other reconfigurations may be performed with the ability to restore the previous device and port configuration information NOTE When a complete firmware update is performed the device port database in memory is erased Restoring Device and Port Information The Import function allows retrieval of saved device and port data that h
2. Class 0 Device P Class 0 Device P Class 0 Device P Class 0 Device P Class 0 Device P Class 0 Device P DPOE MNS Test lab DPOE MNS Test lab undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined undefined F E t t 1 t t E 4 E 1 1 E 1 1 e E 1 E E 1 View All Filter Messages Export Log Clear Log gt gt gt D Figure 10 View Message Log Screen The Message Log area provides a sequential listing of all messages received by the DPoE Element Manager displaying them in a first in first out manner That is the most recently received messages are listed at the top of the window and the older messages are pushed down toward the bottom of the window The rewind and fast forward buttons in the right half of the tool bar for the Message Log area are used to navigate through the message logs should it grow beyond the viewable area 44 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Filter Log Messages By clicking on the Filter Messages button the operator can selectively view and or export a subset of the log messages F Message Log Message Log Filter Parameters Show All Show All Show All C Show All C Show Only C Show Only C Show Only Show Only nb Omen Messages T
3. Element Manager Host Computer to the DPoE Power Patch Panel The computer that hosts the DPoE Element Manager can either be directly connected to the DPoE Power Patch Panel or connected through the Ethernet network If the PC is directly connected to the DPoE Power Patch Panel the PC must either be setup as a DHCP Server or the panel must be setup for a static IP address If the PC is connected to the DPoE Power Patch Panel through an Ethernet network the network must have a DHCP Server on it or the panel must be setup for a static IP address Once the PC is logically connected to the first DPoE M Power Patch Panel successive panels may be daisy chained to the previous panel by connecting the OU T management port on that panel to the IN port on the next panel These connections are made via a RJ 45 standard patch cord refer to the Installation section for more information on daisy chaining the panels together NOTE There is no need to connect the OUT management port on the last DPoE M Power Patch Panel in the daisy chain to anything IMPORTANT Directly connecting a PC to the panel will either require the PC to be setup as a DHCP Server or require the DPoE M Power Patch Panel to be setup for static IP addressing The panel factory default setting is DHCP addressing If a panel is changed to static IP addressing make sure the static IP address is recorded no communication to the DPoE M Power Patch Panel can b
4. stripped ends of the power harness into the DPoE M Power Chassis If the power harness is not long enough or the 48 VDC source requires a specific connector strip the ends of the wire to the same strip length being careful not to damage the conductors 12 Using the two butt splices provided with the panel and paying attention to the polarity of the supply voltage crimp the power harness wires to the supply wires A crimping tool such as the PANDUIT part CT 100 may be used The provided butt splices PANDUIT part BSV14X support 14 16 AWG solid or stranded wire 13 Lightly tug on the butt spliced connections to verify that the butt splices are secure 5 16 7 9mm strip length From SF RTN A DPoE Power System SEL o e 48V B SIR RTN B The power supply connections are polarized The DPoE Power Panel will not function if power is wired improperly The overall length of the power harness between the power supply and the DPoE Power Panel should not exceed 35 feet The included power harness has two wires for the A feed power only pins 1 amp 2 The DPoE Power Patch Panel supports an optional redundant B feed power option but the terminals and wire leads are not attached to the power harness Contact PANDUIT Technical Support for more information about connecting the redundant B Feed Power NOTE Per IEEE 802 3af ensure that the power supply provides a minimum of 1500V insulation between battery and cha
5. the DPoE Power Patch Panel Packaain For non shielded panels refer to Table 2 Package Contents for shielded ging panels refer to Table 15 Package Contents 60 PANDUIT DPoE Power Patch Panel User Manual GLOSSARY AWG DHCP IEEE IP LED MAC MHz NMS o d PC PD PoE SNMP SAE UPS V2C VDC American Wire Gauge Dynamic Host Configuration Protocol Institute of Electrical and Electronic Engineers Internet Protocol Light Emitting Diode Media Access Control Megahertz Network Management System Outside Diameter Personal Computer Powered Device Power Over Ethernet Simple Network Management Protocol Society of Automotive Engineers Uninterruptible Power Supply SNMP Version 2 Communications Volts Direct Current 61 Part Number PNA39F
6. 11 OPENS a window Update Delay seconds 0 that identifies the MH IP address device Maximum Retry 4 type and device Retry Interval seconds 300 name The window Error Log File DPaE24U1xXG017000 MACODUFSCO as shown in the DPoE Element TORIS Manager Firmware pdate Status Done Update Screen can Update Error Code noError then be used to initiate the TFTP firmware update by Helen Begin Update the network operator entering the firmware filename and IP address of the Close TFTP server 4 Enter the TFTP information in the DPoE Element Manager screen and then click on the button 5 Observe the System status LED begins flashing red on the DPoE Power Patch Panel refer to Table 13 DPoE Power Patch Panel Firmware Update LED Status for the LED activity during the Firmware update 6 Allow sufficient time for the Firmware Update to complete Approximately 10 minutes 7 When the Firmware Update is complete the System status LED resumes flashing green 52 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Table 12 DPoE Power Patch Panel Firmware Update LED Status Color and activity Color and activity FE SN d Red Solid Off Initialization Amber Solid DHCP Initialization Green Blink DHCP complete 01 100 seconds a Application Running Green Blink p in progress RedslowBlink cRCcode 4seconds Red update Eo
7. 18 08 22 15 08 22 11 08 22 07 08 21 39 ODDFSCOD12B7 ODDFSCOD12B7 ODDFSCOD12B7 ODOFSCOOD12B7 ODDFSCOD12B7 OOOFSC001 2B 7 ODDFSCOO012B7 ODDFSCOO12B 7 ODDFSCOO12B 7 ODDFSCOD12B7 DDDFSCOD12B7 ODDFS3COD12B7 ODDFSCOD12B7 ODDFSCOD12B7 ODDFSCOD12B7 OOOFSCO01 2B 7 OOOFSC001 2B 7 OOOFSC001 2B 7 ODDFSCOO12B7 ODDFSCOO12B7 ODDFSCOD12B7 ODDFS3COD12B7 ODDFSCOO12B7 132 168 0 123 132 168 0 123 192 168 0 129 192 168 0 129 192 168 0 129 132 158 0 123 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 192 168 0 129 132 168 0 129 PD connected Class 0 Device Phys Location information changed Devic Device Agent Cold Start PD detection failure for PD Type De Device Agent Cold Start Device power below threshold of 20 PD disconnected Class 0 Device P PD disconnected Class 0 Device P PD fault Class 0 Device Physical Lo PD disconnected Class 0 Device P PD disconnected Class 0 Device P PD fault Class 0 Device Physical Lo PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected PD disconnected Class 0 Device P Class 0 Device P Class 0 Device P Class 0 Device P Class 0 Device P
8. 255 2595 SNMP Read Community publc SNMP Write Community private Trap Settings Panel Attributes Tones di Tiepr o Send Panel Name BL Panel 0 12 bb Enable IF Address Community Sting SNMP Critical Major Minor Advisory Rack Name BL Desk Rack SNMP Trapt 7 172163915 pubic Iac v v e Iv Iv Rack Space Postion p SNMPTrap2 py 172 16 37 227 pubic yer WF wv wv F ContactName oeQ Puic SNMPTsp3 m pooo i pedre Tr r r Panel Physical Location Panduit Corporation 1050 Power SupplyLocatio TRI OnDesk Power Threshold feo amp WW Enable Trap Once this information is entered select Save and the new settings will be saved to the device and the device will respond to those new settings 26 DD Y EW WN HN a I WN NOTE If the computer running the DPoE M Element Manager is not in the subnet for the new IP address and cannot communicate with it you will receive a timeout message similar to the one below e SNMP error with agent at 172 16 37 88 Timeout In order to correct this you will need to place the computer in the appropriate subnet or correct the network settings of device to the proper setting lf you can no longer communicate with the device see the section on Device IP Address for instructions on how to set the device to the default network settings Refer to Panel IP Address for more information Occasionally when retrievi
9. Device DPOE MNS Test lab IP Address 192 168 0 129 Panel Information SNMP Settings High Power Information V ISU al SSS General Information Power Information o display of Communication Status Offline Power Rating 480 Walts IP Address 192168 0 129 Operating statia BN Sis Hana fro nt pa ne DHCP Yes Power Input Bus A 54 13 Volts Power Input Bus B 0 Volts DD DF 9C D0 12 View Port Info MAC Address 00 0F 9C 00 12 B7 Power Threshold 20 Hardware Version 1 0 Threshold Notification Trap True Firmware Version Panduit Powered Patch P Power Consumption 212 4 Watts ContactName Joe Mash 0 10 20 30 40 50 60 70 80 30 100 M ess ag es Physical Location MNS TEST LAB EE EN 111 Export Log Power Supply Location Rack DPOEPWRB120Y Current Power Usage 44 specific to l4 View Entire Log 1 5 2007 13 25 12 1 5 2007 13 22 08 Device Agent Cold Start 145 2007 08 53 30 PD detection failure for PD Type Device Physical Location 1 5 2007 08 53 28 Device Agent Cold Start 1 5 2007 08 24 59 Device power below threshold of 20 7 06 W 1 5 2007 08 24 55 PD disconnected Class 0 Device Physical Location 1 5 2007 08 24 52 PD disconnected Class 0 Device Physical Location 1 5 2007 08 24 48 PD fault Class 0 Device Physical Location 1 5 2007 08 24 44 PD disconnected Class 0 Device Physical Location 1 5 2007 08 24 40 PD disconnected Class 0
10. Device Physical Location 1 5 2007 08 24 37 PD fault Class 0 Device Physical Location 1 5 2007 08 24 33 PD disconnected Class 0 Device Physical Location 4 Online 7 Select the Edit DPoE device Info and the following form will open This is where the DPoE Panel Attributes can be entered 28 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F BL Panel 0 12 bb Panel IP Address SNMP Settings DHCP IP Address 172 16 39 151 Panel Settings C Static Subnet Mask SNMP Read Community public SNMP Write Community private Gateway 172 16 35 40 Trap Settings Panel Attributes Types of Traps to Send Panel Name BL Panel 0 12 bb Enable IP Address Community Sting SNMP Critical Major Minor Advisory Rack Name BL Desk Rack v SNMPTrapl y 172163815 pbic wc gt lv lv Iv Iv Rack Space Position Do SNMP Trap2 y 1721637227 public ec gt v Iv Iv Iv Contact Name Joe Q Pubic SNMP Trap3 7 mya Panel Physical Location Panduit Corporation 1050 _ Panel Attributes Power Supply Location TRI On Desk Panel Mame EL Panel 0 12 bb Power Threshold 80 VW Enable Trap Pack Name EL Desk Fack esk Hac Hack Space Position 2 Contact Hame ne BD Public Fanel Physical Location Panduit Corporation 1050 _ Fower Su
11. Flashing The management link on the DPoE M Power Patch Panel is configured correctly and communication messages are currently being processed Green Solid The management link on the DPoE M Power Patch Panel is configured correctly but no communication messages are currently being processed i e the link is idle Amber Solid The panel is currently trying to acguire DHCP address information from the network 16 If the system is otherwise operating normally and an Ethernet 10 100 cable is connected this could be an issue with the panel s management interface Normal operation Normal operation If this persists for more than a minute or two the daisy chain of connections between multiple panels may be incorrect or there are problems at the DHCP server PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F DPoE ELEMENT MANAGER SOFTWARE The DPoE Element Manager software is used to remotely control configure and monitor a DPoE Power Patch Panel within a network Once installed on a shared or dedicated Windows based Personal Computer PC the DPoE Element Manager can be used to manage an entire network of DPoE devices The DPoE Element Manager is on a CD ROM included with the DPoE Power Patch Panel The DPoE Power Patch Panel does not require the DPoE M Element Manager software to operate Installed power patch panels will source PoE power without the software Software prov
12. LED Description Status of Power Status Ports No Powered Device PD is connected Power is NOT being to this particular port on the panel delivered down this port on the panel Amber Solid The panel is determining the PD s power Power is NOT being requirements This occurs for 5 seconds delivered to this port after the PD is connected on the panel Green Solid Port is providing power Power is being delivered to this port on the panel 15 PANDUIT DPoE Power Patch Panel User Manual LED Color Port LED Description Status of Power Status Ports Power is NOT being delivered to this port on the panel Solid The system has failed to determine the PD power requirements for this port Perhaps this PD is not an 802 3af 2003 compliant or Cisco legacy power device Also pins 1 2 amp 3 6 of a connected non powered device such as a PC may be terminated in such a way that the power patch panel attempts to detect it as a PD The DPoE Element Manager may be used to turn detection off to this port so no further checks occur see DPoE Element Manager section The LED will extinguish This may also be an indication of a short in the wiring The connections at both ends of the horizontal cabling should be checked to ensure proper wiring has been followed Table 8 Network Status LED Indications Part Number PNA39F LED Color Network LED Description Status No connection to the management system Green
13. NN Slow Blink Exiting the DPoE Element Manager The Exit option under the File pull down menu or the button 38 will exit the DPoE Element Manager 53 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Resetting the DPoE 1Gb Power Patch Panel In the event of a lockup condition or a lost device the DPoE 1Gb Power Patch Panel has the ability to be hardware reset A typical reguirement for performing a hardware reset would be a processor reset a DHCP reset an SNMP community reset or a complete reset to the factory default settings The reset operation is initiated by inserting and holding in a conductive wire loop straightened paperclip into the two RESET holes located at the bottom of the IN management port RJ45 connector Once the wire is inserted there are four levels of reset actions that can be enabled Each of the four ee DD DW PETRA reset levels is accomplished by holding in the conductive wire for subseguently longer time durations The RESET levels are indicated by flashing state and colors of the LED located above the port See Table nn DPoE TM 1Gb Power Patch Panel Hardware Reset LED Sequence Detailed Description of the Hardware Paperclip o Reset Procedure 1 When the reset is actuated with the wire the system and rear LED will light solid red for 05 seconds If the reset wire is released during this time nothing will happen 2 Ifthe reset wire is actuated for an add
14. Remove 1 inch 25 4 mm of cable jacket being careful not to damage the conductors 7 Fan out all four twisted pairs in the specified wiring sequence refer to color coded wiring positions in Table 4 Color Coded Wire Positions for 802 3af 2003 The colors are also displayed on the Wiring Template Label installed in step 2 on the back of the DPoE Power Patch Panel The DPoE Power Patch Panel can terminate most 22 24 AWG solid or stranded IWC wire with a 050 1 27mm max o d either PVC or Plenum rated 11 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Table 4 Color Coded Wire Positions for 802 3af 2003 Complaint Devices EIA TIA 568B WHITE BLUE BLUE WHITE ORANGE 8 Lay conductors into the punchdown slots for the specified port using the correct wiring seguence Cable jacket removal should be minimized to the extent possible Conductor untwist should be within 2 12 7 mm of termination NEVER TOUCH UNINSULATED COMMUNICATIONS WIRING OR TERMINALS UNLESS THE COMMUNICATION LINE HAS BEEN DISCONNECTED AT THE NETWORK INTERFACE NOTE Never install wiring in a slot previously used for a larger gauge wire 9 Using the punchdown tool PANDUIT part PDT110 punch down the connector into the punchdown slots on the back of the DPoE Power Patch Panel NOTE When using punchdown tool set tool to High setting for optimum performance INSTALLATION Ensure that cabling to powered devi
15. UserName The installer will guide you through the steps required to install Panduit Element Manager on your only default or whether computer other users of this PC can access it Once this selection is made the installation process completes in only a few minutes Panduit Element etur NING This computer program is protected by copyright law and international treaties thorized duplication or distribution of this program or any portion of it may result in severe civil minal penalties and will be prosecuted to the maximum extent possible under the law Setup succeeded After the DPoE Element Manager installation completes exit the DPoE Power Patch Panel Support Tools CD remove the CD ROM from the CD ROM drive and store it in a safe place Next launch the DPoE Element Manager application via the icon on the desktop The splash screen will appear When prompted UserName administrator Password Panduit password is case sensitive and should be changed from this default The DPoE Power Patch Panel Support Tools CD ROM also includes the option to uninstall the DPoE M Element Manager Critical updates to the support programs may occasionally come from Microsoft Corporation The Windows Update option from the PC s START Menu can be used to periodically check for such updates 18 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Connecting the DPoE
16. adding an IP address amp Subnet Mask if desired to be consistent with the rest of his her network The Gateway field is the IP address of a gateway If the DPoE Element Manager and the DPoE Power Patch Panels are on different networks or if the Simple Mail Transfer Protocol SMTP server is on a different network from the panel the panel will send those messages to the gateway IP address specified NOTE The DPoE Power Patch Panel supports either static IP addressing or DHCP address selection Panel Attributes This portion of the screen can be used to set the Panel Name Rack Name Rack Space Position Panel Physical Location and Power Supply Location These fields are freeform and while these fields will not change the operation of the DPoE M Element Manager they allow the DPoE M Element Manager to present the panel and rack information in a user friendly format For example with these fields set panels in the same rack will be grouped together in the Tree View of the Network area on the system level opening screen Likewise panels wired in a single rack will be displayed consistent with the value in the Rack Space Position field refer to Provisioning the Panel for more information Once these values are set in the DPoE Element Manager this information will be transmitted and stored in the DPoE Power Patch Panels Two additional fields are available on this screen and affect the operation of the panel The first field
17. allows network operators to remotely perform routine maintenance and monitoring of any DPoE devices in their network The DPoE Element Manager allows operators to graphically view and monitor DPoE device status fault conditions and overall power consumption In addition the DPoE Element Manager allows the operator to designate power priority to individual ports A Network Management System NMS such as HP Software can use this pre configured information from the DPoE Element Manager to guarantee mission critical devices remain operational NOTE DPoE Power Patch Panels cannot be used for analog or non Ethernet devices Panel Status Port number LED Port Status LED one per port RJ 45 connector one per port 3 gem Figure 1 DPoE Power Patch Panel Front View PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F OUT management Duplex capable A ee our eS ee ane AM Network Status LED Connections connections IN management port and IN Network Status LED Figure 2 DPoE Power Patch Panel Rear View Features and Benefits The following table highlights some of the capabilities of the DPoE Power Patch Panel along with the tangible benefit to the network operator DPoE Power Patch Panel Feature Benefit Powers up to 24 devices from a centralized By using PoE a network operator can more cost location effectively deliver power to PoE Powered Devices PD up to an aggr
18. double click Welcome Welcome to Solarwinds TFTP Server Setup program This program will install Solarwinds TFTP Server on your computer Ware IE is strongly recommended that vau exit all Windows programs Before running this Setup Frogram Click Cancel ta quit Setup and close any programe vou have running Click Next ta continue with the Setup program ey SS WARNING This program i protected by copyright law and international treaties a TN Unauthorized reproduction or distribution of this program ar any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under Iaw Cancel Click Next 96 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F End User License Agreement Click Yes Please read the following license agreement Use the scroll bar to view the rest of this agreement SOLAR WINOS NET End User License Agreement PLEASE READ THIS END USER LICENSE AGREEMENT ELLA CAREFULLY BEFORE DOWNLOADING DOR USING THIS SOFTWARE BY CLICKING ON THE ACCEPT BUTTON OPENING THE PACKAGE DOWNLOADING THE PRODUCT DF USING THE EQUIPMENT THAT CONTAINS THIS PRODUCT YOU ARE CONSENTING TO BE BOUND BY THIS AGREEMENT IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS AGREEMENT CLICK THE OO NOT ACCEPT BUTTON AND THE INSTALLATION PROCESS WILL NOT CONTINUE IN SSS ADDITION 1 IF YOU PURCHASED THE PRODUCT RETURN THE PROD
19. network that supports the new settings or your PC is placed into the new subnet This is expected behavior 3 Using the Discover capability of the DPoE Element Manager search the subnet where the DPoE Power Patch Panels have been installed 4 When the DPoE Power Patch Panels are discovered they will appear in a table as shown below 2 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F E Panduit Element Manager Fie Devices Tools Help LI I1 a MAC Address IF Address DHCF El Hai ES Rack ID not set DO FSCDODU3E2 172 721 100 6 No undefined Rack ID not set mmm undefined Message Log Mg H Date Time MAC Address IP Address hM essag 5 The table contains the MAC and IP address of the all of the discovered DPoE devices The message log will include the MAC and IP address of the newly discovered device s The MAC Address can now be used to associate the discovered device with the information contained on the installation worksheet and the Panel Attributes can now be entered 6 Double click on the row in the table containing the first newly discovered panel After the panel information is gathered from the panel the View Panel Screen will open and will look like this EP Panduit Element Manager File Devices Tools Help E B Racks B Test Lab mm DPOE MNS Test lab UE Ron MW RERUM ELSE tee gg a See ee a Rack Name TestLab Rack Space Location 1
20. not operate correctly without these two support applications being installed on the same PC Microsoft NET Framework cannot currently be installed on 64 bit computers 17 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Installing the DPoE Element Manager Software The DPoE Element Manager is installed by running the setup program on the DPoE Power Patch Panel Support Tools CD ROM included with the DPoE Power Patch Panel Once the CD ROM is placed in the personal computer s CD ROM drive the setup program will automatically run and will give the user the choice to install the DPoE Element Manager software or choose from other selections When selected the installation software will first verify the necessary support software is available on the computer or will prompt the user to determine whether these packages should be installed along with the DPoE Element Manager refer to Table 9 PC Minimum Requirements for DPoE Element Manager for more information NOTE If the CD does not autorun browse the root directory of the CD and double click on the file Launch exe Once all reguired support software is installed the installation screen will be displayed For security purposes the fey Panduit Element Manager network operator will then be given the opportunity to Welcome to the Panduit Element Manager Setup restrict the DPoE Element Wizard Manager to the administrator
21. panel is highlighted in the Tree View of the Network area on the system level opening screen the View Panel Screen for that panel will appear Using the Copy Panel capability will copy all panel level information into a buffer By then selecting another panel on the Tree View of the Network perhaps a newly added panel the paste panel capability is used to paste the panel level information Panel Attributes SNMP Settings and Trap Settings from the first panel to this second one The paste panel Capability can continue by selecting another panel and selecting the Paste Panel option again NOTE The Paste Panel option does not overwrite the IP Addressing information for the panels refer to Edit Panel Information The Delete Panel option under the Tools pull down menu provides an easy mechanism to delete a panel from the DPoE Element Manager This may be required if panels are being pulled from the network Once a panel is highlighted in the Tree View of the Network area on the system level opening screen the View Panel Screen for that panel will appear Using the Delete Panel capability will erase all panel level information in the DPoE Element Manager for this panel Since the master copy of all Panel information is stored in the panel itself use the Discover capability to find the panel in the network and restore the information if it was erroneously deleted 3 PANDUIT DPoE Power Patch Panel User Manual Part Number PN43
22. the DPoE Power Patch Panel is its ability to continue supplying Power over Ethernet during firmware updates All IEEE 802 3af and Cisco In Line protocol legacy powered devices connected to the Panel will remain powered during a firmware update Cisco In Line protocol legacy new powered device detection may experience an interruption during a firmware update Insure that the DPoE device is connected to a Network with the PC that has the DPoE Element Manager application running and has the device to be programmed discovered refer to Panel Discovery section 51 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Detailed Description of the Firmware Update 1 Download the new DPoE product file from http Awww panduit com Support Software index htm to a directory location on your intranet internal network 2 Start a local TFTP server This may require downloading and configuring TFTP server freeware or shareware from the Internet refer to the TFTP Server Install Document Note When configuring your TFTP Server the E Firmware Update TPTF root directory must point to the directory where the Firmware Update TM new DPoE IP Address 192 168 0 129 product file is Device Type Panduit DPoE 24 Port Gigabit Power Patch Panel stored Device Name DPOE MNS Test lab 3 The Firmware Update option under the Tools Firmware Filename DPOE24U1XG117000 hex pull down menu TFTP Server IP Address 172 16 36
23. 9F Backup of Panel and Port Information Once a DPOE device has been discovered information from that device can be exported using the Export Device Information in the Tools menu bar This may be necessary if the DPOE information needs to be backed up in the event of a complete firmware update to Keep records of established information or as a means to copy information from established units into new units prior to configuration Export Device Information Infarmation to Export C All Devices Devices in Selected Rack Room Selected Device Refresh Data Cancel A dialog box will appear allowing device information to be exported for All Devices Devices that are in the Selected Rack Room or for the Selected Device The Refresh Data box prompts the system to obtain the most recent information from the device After hitting OK a dialog box will appear requiring a file name and desired location to save the file The first data file will be the panel summary information network physical allocation etc Save Device Information As save in See IBM_PRELOAD L 4 C efad7e9n179e47e324an5279c2955ab3 HP OV NNM Support Ue 9 Sbabb1basefesesd 7 7f di al 1386 ly Recent Documents Desktop My Documents My Computer 2006 Perf review 9 A Jack Files BISCI Meeting Notes CD Test Folder Ga Comnet Files Complete Release dist Documents and Settings Download 3 Downloads DRIVERS
24. DPoE 1GiG Power Patch Panel User Manual Copyright 9 2008 PANDUIT Corp All rights reserved No part of this book shall be reproduced stored in a retrieval system or transmitted by any means electronic mechanical photocopying recording or otherwise without written permission from PANDUIT No patent liability is assumed with respect to the use of the information contained herein Although every precaution has been taken in the preparation of this book PANDUIT assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein Part PN439F Published October 2008 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F SAFETY WARNING Always observe standard safety precautions during installation operation and maintenance of this product Read the installation instructions before connecting the unit to its power source There are no user serviceable parts inside the unit To avoid the possibility of electric shock the user should not perform any adjustment maintenance or repairs or open unit Do not work on the product or connect or disconnect cables during periods of lightning activity Ultimate disposal of this product should be handled according to all national laws and regulations WARRANTY Unless otherwise specified all products presented in this user s guide are warranted against defects in material and workmanship for a perio
25. Device undefined anel Information SNMP Settings High Power Information General Information Communication Status Online IP Address DHCP MAC Address Hardware Version Firmware Version Power Information 172 21 50 43 Yes Power Input Bus A Power Input Bus B Power Threshold 1 3 Threshold Notification Trap 00 0F 9C 00 00 72 Panduit Powered Patch P IP Address 172 21 50 43 Power Rating Operating Status Power Consumption Edit Panel Info 480 watts ON Export Panel Info 53 2 Volts D Volts View Port Info oz 7 1 Watts Contact Name 0 10 20 30 40 50 60 70 80 30 100 Ll bl teats Current Power Usage 1 Physical Location undefined Export Log View Entire Log 15 15 22 N A New Device Discovered Power Supply Location Power Source Name not 10 15 2007 The Settings pop up screen will appear allowing you to set SNMP retries from 0 to 9 times Settings Online Power Warning Threshold Hack Space Mumberng Ascending SMMP Timeout Value 10 Seconds SNMP Fietries E Cancel 35 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F SNMP Access and Security The security for the agent is based on a modified version of the security methods provided by the IETF A set of users is provided with varying capabilities The administrator account is able to change passwords and Authentication Levels noAuthNoPr
26. MP setting or the trap settings After any changes are made be sure to click on the button to store the information and transmit it to the DPoE Power Patch Panel 31 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Active Port Indicator By clicking on any device port its status information will be displayed and the selected port will be highlighted with a yellow flashing indicator on the EMS screen When the select device is displayed you can click on a port for this example port 5 and the selected port will highlight with a flashing yellow indicator You will receive a dialog box on screen stating that the EMS is obtaining the latest information for the selected port P Panduit Element Manager 3 cj a m ale 2 Bi Racks Rack Name undefined Rack Space Location 1 B Alpha Test Southeast Network B LAN B Rack ID not set Panouir umm LLYYYY DYDY YY DYDY YY mm undefined Ur am saj SYSNAME Apri4 26 Device undefined IP Address 172 21 50 43 mmm undefined l Rooms Panel Information SNMP Settings High Power Information General Information Power Information Edit Panel Info Communication Status Online Power Rating 480 Watts i Export Panel Info IP Address 172 21 50 43 Opasno SI Hn EF 53 78 Volts 0 Volts View Port Info 0 9 4 Watts Obtaining latest information for port 5 Contact Name 0 10 20 30 40 50 60 70 80 30 100 Physical Locatio
27. N LN EUER 45 helresn thie NebWOEK s ovev ode revo See enu edo dvo ede iod vb uo oov unde ede ea 46 Administering E mail Settings ioi neto e a eee 46 Scarch Ior Specie Panels OF Pori Se ient e a mn e mS i d i redes 47 DPoE Element Manager Log Messages eeeeeeeenneenennnennnnennn 50 Miscellaneous Seling S esana Gan DG a GG GY SD 51 DPoE Power Patch Panel Firmware Update eseseseeesssusss 51 Detailed Description of the Firmware Update cccccccseeeceeeeeeeeeeeeeeeneeeeaees 52 Exiting the DPoE MElement Managetl cccccccsecccseeceeeceecceeeceeeseueeneeenseesees 53 Resetting the DPoE 1Gb Power Patch Panel cccsescccseeeeeseeeeeeeeeeseeeees 54 APPENDIX 1 BASIC TROUBLESHOOTING 0 ir FF LL LL LL uuuuu 55 APPENDIX 2 TFTP SERVER INSTALL en tdi ep nes dew 56 TECHNICAL SPECIFICATIONS vivi iade ae GY nen diw 60 GLOSSARI o i ULM M D d 61 Figures Figure 1 DPoE Power Patch Panel Front View cccccecceeececceeeeeeceeeseeeseeeaeeeeees D Figure 2 DPoE Power Patch Panel Rear View esses 6 Figure 3 System Level Opening SCreeN cccccceecccceececeeeeeceeeeesaeseesseeeesseeeesseeeesaaeess 20 Figure 4 View Patel Oel eel ec ope tus RE tes ae aa Ra eae 30 Figure 5 View Device Screen SNMP Settings ce cccesseeesesseeeessaneeesseeeeesaneeees 31 Figure 6 Edit Panel Sel GB O ene
28. System combine with Panel Extender Brackets SRB19BLY PANDUIT part PEB1 to adjust to 19 mounting space Cable strain relief bar w 2 extension off rack Note PAN TY Cable Ties PANDUIT part PLT1 5M C for SRB19BLY are sold separately Table 4 PANDUIT Corp Contact Information PANDUIT Technical Support Fax 1 708 444 6993 E mail _ cs Opanduit com For Installation Instructions in Local http www panduit com Support Software index htm Languages and Technical Support Worldwide Subsidiaries and Sales www PANDUIT com Offices Latest Software Updates http www panduit com Support Software index htm IMPORTANT The DPOE Installation Worksheet should be used to record pertinent information when installing DPoE Power Patch Panel s particularly if the DPoE Element Manager is monitoring the network refer to Provisioning the Panel for more instruction on how this information will be entered in the DPoE Element Manager The installer should complete this worksheet PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Panel Mounting Procedure Only trained and qualified service personnel should install or service DPoE Power Patch Panels Before installing or servicing DPoE Power Patch Panels or communication wiring be aware of the hazards with the associated electrical circuitry ATTENTION Observe precautions for handling electrostatic sensitive electronic devices when installin
29. T DPoE Power Patch Panel User Manual Part Number PN439F r TFTP Server Configuration ur DPoE 08S ZB 117000 hes 2 tgPminismndsmnd zwi LIF Cancel Help Select the directory that contains the new DPoE product file i e C tftp_dir That is it Your TFTP server has now been configured correctly After the download works you will see something like this on the screen that shows the file transfer lt SolarWinds Net TFTP Server EU cun Sent DPoEOSS24G117000 hex to 172 16 37 68 3410360 bytes TFTP Server IP Address used in Panduit Element Hanager Firmware Update screen eftp mw 172 16 39 229 u Note If you are using a TFTP server from another vendor they may have some user settable options If available please set the timeout to 2 seconds and the maximum retransmits to 20 The Solar Winds TFTP server does not make these settings available to the user 99 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F TECHNICAL SPECIFICATIONS 24 port 1 72 H x 19 0 W x 5 08 D 43 7mm x 482 6mm x 129 0mm 1RU Input Voltage Range 44 VDC to 57 VDC 48V minimum to meet IEEE 802af specifications Typical per port f power output IEEE 802 3af 2003 compliant power 15 4 watts port 46VourDC 350mA Maximum overall Mounts to standard EIA 19 rack or 23 rack when used with panel extender Mounting Option brackets PANDUIT part PEB1 Extender brackets are not included with
30. UCT TU THE PLACE OF PURCHASE FOR A FULL REFUND OF 2 IF YOU SRE OTHERWISE ATTEMPTING TO DOWNLOAD THE PRODUCT AND YOU DO NOT Do you accept all the terms of the preceding license agreement If sa click on the es push button f you select No Setup will close Choose Destination Location Click Next Setup will install Solarwinds TFTP Server in the following folder To install into a different folder click Browse and select another Folder fou can choose not to install Solarwinds TFTP Server by clicking Cancel to exit Setup Destination Folder C Program Files S olarvinds Browse Lancel o PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F x Installation Complete Solarwinds TFTP Server has been successfully installed Press the Finish Button to exit this installation For additional Free Network Software visi www Solarwinds Met Some of the more popular downloads include Orion Network Performance Monitor Network Engineer s Toolset Advanced Subnet Calculator Wake On Lan Finish gt Click Finish Now run the program Move your mouse to the Start Menu lower left corner Start Menu gt All Programs gt Solar Winds Free Tools gt TFTP Server r TFTP Server Tools Help SHES rWinds Net TFTP Server Clear Log 2 bgf mind smrd sws prepec AD PoE Beutput 172 716 359 229 Go to the File gt Configure menu 08 PANDUI
31. Users Guide Release Notes Application Notes Installation Guides Power connector housing with wire This wiring harness is used to connect the leads DPoE Power Patch Panel to 48 VDC power supply Not used if the panel is powered by the DPoE Power Supply PANDUIT part DPOEPWRB 120Y 10 Foot Power Harness Rn Used to connect 48V A feed to a power supply Butt splices Two butt splices may be used to extend the 10 Foot Power Harness Should not exceed a total length of 35 feet Verify the above contents arrived in good condition If not contact PANDUIT Technical Support PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Table 2 Power Supplies Available from PANDUIT DPOEPWRB120Y 120 watt power supply 48 volt output Unmanaged power chassis supports 3 rectifiers and optional Network DPOEPWRCU Interface Card NIC DPOEPWRR500 500 watt rectifier for use in the DPOEPWRCU chassis DPOEPWRR1250 1250 wait rectifier for use in the DPOEPWRCU chassis Table 3 Recommended Strain Relief Bars Available from PANDUIT SRBCT e When using Standard TIA 19 rack systems combine either bar with Cable strain relief bar bracket kit PANDUIT part SRBBRKT to provide adequate depth with cable tie clips e When using higher density 19 rack systems such as PANDUIT NetRack Rack Systems no additional brackets are neccessary OR e When using higher density rack systems that have 23 mounting such as NetFrame amp Rack
32. ack space position on the Installation Worksheet The supplied screws are part of a grounding system to ensure that the DPoE Power Patch Panel is properly grounded to the rack USE ONLY THE SUPPLIED SCREWS TO ATTACH THE PANEL TO THE RACK 10 PANDUIT DPoE Power Patch Panel User Manual Network Connection Connecting the Powered Devices Part Number PN439F If the DPoE Element Manager is not being used to remotely manage the network of DPoE Power Patch Panels skip to Connecting the Powered Devices below Otherwise using a standard patch cord for example PANDUIT part UTPCH3 or UTPSP3 connect the IN management port on the back of the panel to an Ethernet switch A DHCP Server must be on this network unless the DPoE Power Patch Panel has already been configured for Static IP operation DPoE Power Patch Panels expect DHCP as a factory default The panel may also be directly connected to a PC with the DPoE M Element Manager installed but this PC must be setup as a DHCP Server If multiple panels are being used in the network the OUT management port from one panel may be connected to the IN management port on the next panel in a daisy chain fashion as shown Once all of the connections are made the DPoE Element Manager or another Network Manager will be able to communicate with all the panels over this daisy chain of connections refer to Provisioning the Panel for more information 6
33. arch For f Show All Search For f Show All Rack Space Location Hack Name f Show All Search For Power Supply Location Part Number PNA39F Show All Search Far Hardware version f Show All 1 Search For Firmware Version qp ipe gu Show Results Close Panel level searches can be conducted by any combination of MAC address Panel Name Rack Name Rack Space Location Hardware Version IP Address Physical Location Power Supply Location Firmware Version 48 PANDUIT DPoE Power Patch Panel User Manual E Search Device Show All Search For Port Number Port Search Parameters f Show All f Search For FD Type t Show All f Search For Work Area Location Part Number PN439F f Show All f Search Far Power Made Show All f Search Far f Show All 1 Search For f Show All f Search For Show All f Search For Show All f Search For Administration Power Control Classification Detection Status Power Priority Legacy Control Note Port searches can take a YERAY lang time depending on the number of ports that match the search criteria Please be patient Show Results Close Port level searches can be conducted by any combination of Port Number PD Type Work Area Location Administration Control Detection Status Power Priority Power Classification L
34. as been previously extracted and saved to a file using the Export function Once a device has been discovered and identified in the DPoE Element Manager retrieved device information may be imported into a discovered device using the Import Device Information function in the Tools menu bar The device to receive the retrieved information is chosen by double clicking on that device s row from a list of all discovered devices NOTE the Import Device Information menu option will not appear if a device has not been discovered or selected Fack Name OM Sales Meeting Pack Space Location 1 Seaa ease CLE Device DPoE Compact 8 IP Address 172 21 51 142 All ports for DPaE Compact B Part Information Port Work Area Location PD Type Power Priority Power Class Power Admin Control PD Detection Status 1 Critical wi UM Searching Orland Park fCiical wW NY Searching Cisco 7940 VolP p Critical Ow ON Searching Table Top Critical Oi OFF Disabled Critical Oi ON Searching Demonstration Area Critical Ow ON Searching Critical wy ON Searching Aw 2104 PoE La Critical Oi ON Searching 39 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F A pop up window will ask for confirmation to import the device information Are vou sure vou want to import Ehe selected device information into the device currently in view This action cannot be undone After confirmation the Import Port screen wil
35. atch Panel Firmware Update LED Status 53 Table 13 DPoE 1Gb Power Patch Panel Hardware Reset Sequence 54 Table 14 Basic Troubleshooting Guide eeeeeeeeeeeeeeeeeeeeeeeneene 55 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F OVERVIEW The DPoE Power Patch Panel provides a reliable and cost effective solution for Power over Ethernet PoE applications complaint with the IEEE 802 3af 2003 specifications Each DPoE Power Patch Panel allows centralized powering of up to 24 devices such as Internet Protocol based IP telephones Network Security Cameras or Wireless Devices over the same cabling used to provide the Ethernet connectivity By eliminating separate power connections to each of the devices the DPoE Power Patch Panel provides a more cost effective solution particularly in cases where the devices are numerous or local powering is impractical The DPoE Power Patch Panel is used to inject POE power into an existing infrastructure without the need for a separate midspan power injector can which increase costs and wiring complexity and affect performance While the DPoE Power Patch Panel may be used as a standalone device it can be configured and monitored from a centralized software application the DPoE M Element Manager This management software application
36. aving the delete the above entered information Refresh 36 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Note that when the SNMP version is set to v3 the SNMP Community String field changes to blank and allow entry of the SNMPv3 Username Also when the SNMP version is set to v3 the security level v3 SecL ev can be selected either 1 No Authentication No Privacy encryption 2 Authentication No Privacy encryption and 3 Authentication and Privacy encryption Trap Settings Community String v3 Type of Traps to Send Enable IP Address SHMPy3 Username SNMP SecLev Critical Minor Advisory na amp uth NaP ri 2 authNoPriv 3 authPriv vac 1 0 0 0 0 public vac 1 c L publi ERE r Refresh Save Cancel The other fields Critical Major Minor Advisory refer to the priority of the messages and allow the network operator to designate which message should be sent to each trap refer to DPoE Element Manager Log Messages for more information Copy Paste Delete Panel Information The DPoE Element Manager also provides a unique feature that will allows the network operator to more efficiently configure the network by allowing all panel level information to be copied from one panel to another The Copy Panel and Paste Panel options under the Tools pull down menu provide an easy mechanism to perform this task Once a
37. ces communicate with the specified device changed using the DPoE Element Manager minimum allowable for PoE minimum allowable for PoE Location Information bade Advisory The DPoE device that was previously discovered has not been relocated to another location in the network 90 PANDUIT DPoE Power Patch Panel User Manual Part Number PNA39F Miscellaneous Settings Several miscellaneous settings must be configured for the DPoE M Element Manager to communicate properly with a deployed network of Power Patch Panels The Settings option under the Tools pull down Settings menu provides an easy mechanism to administer these settings Online w If the Online indicator is not checked H the DPoE Element Manager assumes it is in the Power Warning Threshold ho z offline mode and will not attempt to connect to the deployed Patch Panel Network Changes Rack Space Numbering Descending made within the DPOE Element Manager will not be updated in the panels SNMP Timeout Value ho Seconds When the power consumed on any given panel reaches the Power Warning Threshold below the maximum power level for that particular panel the panel will issue a warning alarm and display that the panel is in the warning range Cancel This above setting is a system wide power warning threshold but it used as a percentage below maximum for each individual panel Some panels in the network might have their maximu
38. ces is protected from inductive coupling from ADVISORY nearby power cables and other sources Ensure that powered devices are properly installed and grounded according to manufacturer s recommendations and all the cabling and connections are isolated from external surges Observe precautions for handling electrostatic sensitive electronic devices when installing this product Ensure you are properly grounded with a wrist strap or equivalent while making connections to the 110 punchdown terminals on the rear of the product Never make any connections to the 110 punchdown terminals when power is applied to the product When installing cabling and making connections to the DPoE panel follow all local standards as well as the applicable TIA 942 standards and IEEE 802 3 Ethernet standards 12 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Power Reguirements 10 If the panel is being powered by a DPoE Power Supply refer to Table 2 Power Supplies Available from PANDUIT for a list of available powering options skip to Powering Up the DPoE Power Patch Panel section below since the DPoE Power Supply is equipped with a matched keyed power connector that will fit the power connector on the back of the panel 11 If the panel is being supplied by a DPoE Power Chassis or a direct 48 VDC source cut the 10 foot power harness to length then strip the ends of the leads to 5 16 7 9 mm Connect the
39. d of one year from the date of sale to the initial purchaser PANDUIT Corp warrants that its firmware designed by PANDUIT Corp for use with the product will execute its functions when properly installed in the product for one year from the date of sale to the initial purchaser PANDUIT Corp does not warrant that the operation of the product or the firmware will be uninterrupted or error free During the warranty period PANDUIT Corp will at its discretion either repair or replace products that prove to be defective For warranty service or repair the product claimed to be defective must be returned to a service facility designated by PANDUIT Corp Buyer shall prepay all the shipping charges to PANDUIT Corp and if in the opinion of PANDUIT Corp the product is defective PANDUIT Corp shall pay shipping charges to return the product to Buyer However Buyer shall pay all shipping charges duties and taxes for products returned to PANDUIT Corp from another country The products presented in this user s guide are not designed intended authorized or warranted to be suitable for use as components in systems used in any life support or critical applications including but not limited to any applications intended to support or sustain life any medical applications any systems used for commercial transportation or nuclear facilities or any other applications where product failure could lead to personal injury death or catastrophic property damage Acco
40. e done without this address Never connect a PC setup as a DHCP Server to an Ethernet network that already has a DHCP Server on it DPoE Element Manager Operation Once the DPoE Element Manager is successfully installed access the program using the shortcut installed on the desktop by the DPoE Element Manager installation software The program is stored in the PANDUIT directory under the programs Please enter your LlzerMame and Password directory and can also be accessed through the START menu User ame administrator After displaying the version number of the DPoE Element Manager the user is Password ees Euneel prompted for a UserName and password When the management system is first installed the default UserName is administrator with a password of Panduit notice the capital P Passwords are case sensitive This default UserName and Password should be changed once the user is familiar with the DPoE M Element Manager software refer to Additions or Changes to UserName Password for more information 19 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Graphical User Interface The DPoE Element Manager has an easy to use graphical user interface with pull down menus and tool bars which make configuring and provisioning the network easy When the DPoE Element Manager software is opened the following system level opening screen appears Pull down menus List View of t
41. e iy SATA Rama Rack Space Date Range Rack Name Location Undiscovered Device Cold Device Agent Cold Start Srat Dare xj From From New Device Discovered End Dat ea PD Connected dacl gne map o m To PD Disconnected PD Fault Device Power Above Thresh Device Power Below Thresh Fuse Blown Show All Show All Show All Show All Port Physical Location Chan Device Self Test Failed Device Self Test Passed Trap Recipient Changed PD Detection Failure Device Agent Lost Communi From From From IP Address Changed Low Device Voltage To Ta Ta High Device Voltage Location information change C Show Only C Show Only C Show Only C Show Only IP Address MAC Address Device Name Port Number Show Results Close Figure 11 View Message Log Filter Parameter Screen Network operator can sort through and view this subset by any combination of Date range Rack number or range of rack numbers Rack space location or range of rack space locations IP address or range of IP addresses MAC address or range of MAC addresses Panel name or range of panel names Port number or range of port numbers Specific message types Export Log By clicking on the Export Log button the operator is given the option of exporting the log file related to particular panel rack or the entire log to a file Clear Log By clicking on the Clear Log button the operator will be given the opportunity to export the log before e
42. e username and passwords Discovery process After entering the Starting IP Address Ending IP Address and SNMP Write Community the button will initiate the Discover capability Scanning in progress x Scanning selected range x Fw HEBHEEEBEBBEBEEEEHBH Whether a subnet search or an IP range search was conducted the discovered DPoE Power Patch Panel information will be populated in the DPoE Element Manager In addition to the Discover capability the DPoE M Element Manager also supports a Refresh capability which collects the information stored in each Patch Panel and verifies that it is consistent with the information in the DPoE Element Manager refer to Refresh the Network for more information 25 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Provisioning the Panel The DPoE Element Manager has the capability to discover all of the DPoE Power Patch Panels in the network and display them in a format where the panels are grouped by their host racks based on the information entered into the panels during the provisioning process These are called Panel Attributes Individually identifying each panel and entering its specific attributes into the DPoE Element Manager is an integral part of the provisioning activity Loading this information into the DPoE Element Manager enables it as well as Network Management Software to be used in an effective working
43. ected the Subnet dialog box will open Subnet Information SNMP Version Well SNMP Write Community private ynot BF Administrative Usemame Administrator Authentication Password Netmask f s Encryption Password The network operator can then add the desired Subnet Netmask SNMP version SNMP write community along with the Administrative Username and Password Once the desired information is entered the network operator can select OK or Cancel Subnet Information SNMP Version v2C SNMP Write Community private Administrative Username Administrator Subnet 472 46 37 0 Authentication Password Netmask 299 299 292 U Encryption Password IMPORTANT SNMP Community fields allow SNMP messages to be exchanged between the DPoE Element Manager and the DPoE Power Patch Panels For security reasons these fields should be changed from their defaults Care should be taken however as the SNMP Community fields are case sensitive and will read inadvertently mistyped spaces or characters In addition the default SNMP Version used for communication with the DPoE Power Patch Panel is SNMP v2c If you change this to SNMP va you will need to change the SNMP Version setting for the subnet discovery to be successful 23 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Once any subnetwork changes are entered if necessary check d those subnets to be
44. ed Clan UU Device Plures Location PD fen Class O Device Physical Location Figure 4 View Panel Screen The top portion of the panel level opening window provides a view of the DPoE Power Patch Panel complete with the current LED status IP address rack name and rack location The information on this screen can be edited by selecting the Edit Panel Info button on the right side tool bar 30 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F P Panduit Element Manager File Devices Tools Help 4 e al ale sia 2 Bi Racks Rack Name TestLab Rack Space Location 1 BB TestLab mm DPOE MNS Test lab e a Rooms Panouir LLYTTY CYTYYTLTDYDYTY YY Device DPOE MNS Testlab IP Address 192 168 0 128 Communication Settings Edit Panel Info SNMP Version Support v1 v2C v3 Administrative Username SNMP Read Community public Authentication Password Export Panel Info SNMP Write Community private Encryption Password Community String Types of Traps to Send View Port Info v3 Enable IP Address SNMPv3 Username SNMP SecLev Critical Major Minor Advisor MW 192 168 0 19 public v2c 7 7 7 7 7 132 158 0 223 public v2C 7 Iv 7 epe 0 0 0 0 public vac 7 E ERU UN Ju 7 El Li i 7 E a View Entire Log Trap Settings 0 0 0 0 public v2C 0 0 0 0 public v2c in Figure 5 View Device Screen SNMP Settings The second tab on this screen allows user to vi
45. egacy Control NOTE The Link Information tab is not supported at this time 49 PANDUIT DPoE Power Patch Panel User Manual Part Number PNAS9F DPoE Element Manager Log Messages The following types of messages are generated within the DPoE Power Patch Panel network and are displayed in the DPoE Element Manager logs While most of these messages are generated by a DPoE Power Patch Panel in the network several of these messages originate within the DPoE Element Manager when for example it looses communication with one of the panels in the network Table 11 DPoE Element Manager Log Messages Level Undiscovered Device Cold Start Advisory The main software process i e the device agent in a previously unknown device is now up and running Device Agent Cold Start Advisory The main software process i e the device agent in a previously known device is now up and running The process will likely reset itself device the panel an acknowledgement risen above the Power Warning Threshold Device Power Below Threshold Major The power consumption at the device has Davies Power Below Teo Maor Men velew tne Power Waring Trestol catastrophic failure of the unit Location information of one of the ports has changed using the DPoE Element Manager Trap Recipient Changed Advisory One of the traps associated with a particular device was changed using the DPoE Element Manager Powered Devi
46. egate 100m 328 ft channel length from the DPoE Power Patch Panel Powering from a centralized location removes the need to power each device separately eliminates the need for separate Uninterruptible Power Supply UPS for critical devices and enables centralized power management by the network operator Combining PoE Power with patch panel The DPoE Power Patch Panel combines patching and functionality power injection into a 1 RU high package This reduces rack space by at least 5096 while providing easier installation eliminating the need for patch cords between Power Hub and a non powered patch panel configuration IEEE 802 3af 2003 Compliant Many currently available PoE powering options are not standards based thus requiring coordination between each device s power needs and the technical capabilities of the in line powering unit Each port on the DPoE Power Patch Panel can automatically detect and support the 802 3af 2003 standard or the legacy Cisco powering scheme Full IEEE 802 3af power to all ports Each port on the DPoE Power Patch Panel is capable of delivering the full POE power specified by the IEEE 802 3af 2003 standard 15 4 Watts at the PSE PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F DPoE Power Patch Panel Feature Benefit Increased System Reliability through efficient thermal design Simultaneous support for the Cisco powering scheme along with the 802 3af 2003 standa
47. er allows network operators to easily view and manage a network of DPoE Power Patch Panels using the industry standard Simple Network Management Protocol SNMP to exchange management information between network devices By eliminating the need for separate midspans and the associated need for patch cords in a network ready 1RU high package The DPoE Power Patch Panel is fast and easy to install Beyond the current IEEE 802 3af 2003 standard the DPoE Power Patch Panel supports a 1 GbE data transmission rate 10 100 1000 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F INSTALLATION The DPoE Power Patch Panel requires a direct connection to a nominal 48 VDC supply A power supply may be purchased separately from PANDUIT or other vendors provided that exact specifications are fully met Installation instructions for the individual power supply are included with that product Package Contents Each DPoE Power Patch Panel is shipped in a box which includes the following Table 1 Package Contents Wiring Template Label For use on the rear panel of the DPoE Power Patch Panel Supports either EIA TIA 568A or 568B wire positions Metric and SAE screws Installation reguires six screws One bag of six metric screws M6x1 0x16 and one bag of six SAE screws 12 24x1 2 are included DPoE Support Tools CD ROM containing DPoE Element Manager software DPoE 1GiG Power Patch Panel
48. euu ueu LY HIL LILI LLI LL I LL Finn 19 Graphical User InterfaC6 99 YYYY a aaa YL LEL LL LLY nennen nnns 20 Additions or Changes to USerName Pa SSWOId ccccceeceseeeeseeeeseeeeeeeeeseeeaees 21 anc DISCOV CTY t a 22 SUBNET SC ANG EN OO Y A ON RC REF FA IF RR FFA FR HRN FIR HD 23 IP TRANG smile T FO OR A FO AF O FFO Cd O 25 PPFOVISIODIDG TNE Panel aa O aa wd dd Fodd DO focus Menta e 26 Administering Port and Panel level Information FLY Y LY nou 30 EIE ame I 119 1 atrii sce esce FROWN FFWR AFF FFIN RENTU FF FFF 31 ACY Por ImdIeatOl ceu aY aY dd SY GYN NN Ar YNA RYG 32 Panel IP PROC SS sehr cites cites GG A Gi i 33 Panel AMOU GS ee ET 33 SNMP SOTA S 2123520 8268 a a CR HR E A 34 SNMP ROI Y essa E aires 34 oONMIEP AGCeSS and SECUN oscars e 36 Li es 11 10 N E EE ET Y E HN NN 36 Copy Paste Delete Panel Information eese 37 Backup of Panel and Port Information seeeseesssesssssse 38 Restoring Device and Port Information ccccccceeeeceeeeeeeeeeeeeneeeeseeees 39 VIEW FOUR OFDGUODT ae Gen Ge Gee GDG o OO T TmTMT 40 GIG mL 10 LL19 10 elt OM deste odd E E uvas qt Ee 41 seb POCEO BEEF NR A Y ETE 43 VIEW ENUO LOO sn YY Y eee 44 Fiter Log IVIe Sa du cib Nr fe sui ee COT GYNNAR ylw GAN 45 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F ON oo MC M CE 45 E oe NER I U
49. ew the SNMP information currently set for this device This screen cannot be used to modify the configuration SNMP information The SNMP configuration can be edited selecting the Edit Panel Info button on the right side tool bar Edit Panel Information In addition to the Edit Panel Info button on the tool bar the Edit Panel option under the Devices pull down menu provides an easy mechanism to perform this task DPOE MN5 Test lab Device IP Address SNMP Settings f DHCP IP Address 175 Communication Settings Static Subnet Mask 5525525580 SNMP Read Community pubis SNMP Version Support Gateway Imm SNMP Write Community private viata z SNMPv3 Device Altnbutes Trap Settings Device Mame DPOE MNS Test lab Community String v3 Types of Traps to Send Enable IP Address SNMPv3 Username SNMP SecLev Critical Major Minor Advisory Rack Mame Test Lab Rack Space Position IR Tapi fv 132 168 0 13 public vac ContactName oeNah Trap2 v 1321680223 public vor va ow eL Iv v w Xl Xl Trap 3 aaao pubi r Physical Location MNS TESTLAB l inus 0 0 0 0 public x j I mo Power Supply Location Rack DPOEPWRB120Y re 0 0 0 0 public vat Tep5 ono pabi ac fi Power Threshold 20 9 Enable Trap rap 0 0 0 0 public v Xl Figure 6 Edit Panel Screen This screen will allow the network operator to change the panel IP address the panel attributes the SN
50. g this product Ensure that you are properly grounded with a wrist strap or equivalent while making connections to the 110 punch down terminals on the rear of the product Never make any connections to the 110 punch down terminals when power is being applied to the product Rack Mounting Instructions 1 Record the MAC address printed on a sticker on the back of the unit by writing it in the space provided on the included Installation Worksheet ES PANDUIT part PN377 SS ISSN Slip the Wiring Template Label over the rows of connectors on the back of the DPoE Power Patch Panel making sure the proper wiring code is facing out and that the writing is not upside down One side of the label indicates EIA TIA 568A wiring while the other side is EIA TIA 568B wiring Grounding Requirements 3 Using a screw from the SAE screw set denoted by 01881 38 REV 2 attach the green and yellow striped grounding strap to the panel via the unthreaded hole nearest the power connector Next install the panel into a grounded rack using the appropriate screw set provided to ensure proper grounding between the panel and the rack Finally attach the loose end of the grounding strap to the rack within the same position as the panel PANDUIT structured ground kits for data center rack grounding can be used to properly ground PANDUIT NetRack Rack Systems and racks from most other manufacturers Grounding Strap Record the r
51. he DPoE device area E Panduit Element Manager Mja xl File Devices Toos Hp 0 X 4 s of aj xi URSS MAC Address IP Address DHCP Device Name Rack Name Rack Space Physical Location Contact Name Power a Rooms m Network Area et i Message Log Msg Date Time MAC Address IP Address Message Device Name Por Message Log area Tool bar for Message Log Online indicator f View All Filter Messages Export Log Clear Log lt lt lt gt gt N NN Figure 3 System Level Opening Screen The system level opening screen is broken into three areas the Tree View of the Network area the List View of the DPoE Power Patch Panels and the Message Log area By working in each of these three areas the network operator can easily monitor the overall status of the DPoE M Power Patch Panel network the status of individual patch panels or the status of individual ports on individual panels Likewise configuration changes can be made at the network panel or port level The Tree View of the Network area provides a hierarchical display of each patch panel within the network using the configurable names assigned by the network operator Multiple patch panels physically wired into a single rack are grouped on the screen under the configurable name of that rack Using the computer mouse the operator can select a specific rack and the display will expand to show the indi
52. iant powering or the Cisco In Line powering scheme In the Forced with check mode the device port will deliver power only when a non open circuit is detected The port checks for a closed circuit condition and will not apply power until a load is detected across the circuit In Forced mode the device port will deliver power without performing a detection classification If nothing is detected within the circuit then no device connected traps will continuously be generated until a load is connected 42 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Forced power mode is not a normal operating condition Although Forced mode abides by the PoE under and over current shut down precautions potential damage could be caused to certain non PoE devices that are connected in Forced mode Work Area Location These free form fields allows the network operator to enter information such as the location where the device is located Legacy Detection These settings Enabled Disabled allow the PoE device detection to be modified If this setting is Enabled the DPoE MPower Patch Panel will detect both Cisco In Line powering scheme and the IEEE 802 3af 2003 standard powered devices If this setting is disabled the DPoE Power Patch Panel will perform IEEE 802 3af detection Export Log The Export Device information capability is similar to the Export Device capability This function allows the network operator to copy
53. ides an optional enhanced level of remote management monitoring and maintenance for a single device or an entire network of DPoE devices Latest updates at http www panduit com Support Software index htm Hardware and Software Reguirements Table 9 PC Minimum Requirements for DPoE Element Manager Hardware PC with 300 megahertz MHz Pentium class processor or eguivalent RAM 128 MB of RAM 256 MB recommended 45 MB of available hard disk space 10 100 Ethernet card CD ROM Drive Software Operating System Any of the following e Windows Vista e Windows XP Professional Service Pack 1 or later e Windows XP Home Edition Service Pack 1 or later e Windows 2000 Service Pack 4 for Windows 2000 Support Applications Microsoft NET Framework 1 1 Redistributable or later 1 2 Microsoft Data Access Component version 2 7 or later See notes below Display Settings For XP Professional or Home Edition e Settings 1024x768 or larger e Color Quality Medium 16 bit or higher e Advanced Normal Size Fonts 96dpi REQUIRED e Appearance Font Size Normal REQUIRED For Windows 2000 e 1024x768x32K colors Small Fonts REQUIRED Normal 96dpi If Microsoft NET Framework version 1 1 or Microsoft Data Access Components is not currently installed on the PC the user will be prompted to install these software packages first before installing the DPoE Element Manager The DPoE Element Manager will
54. ill allow the network operator to distinguish one panel from another refer to nstallation for more information on installing the DPoE M Power Patch Panels The Discover option under the Devices pull down menu will perform this task or click the button amp on the top tool bar on the system level opening screen Discover Devices By Subnet 172 16 37 0 255 255 255 0 private EA 172 16 38 0 255 255 255 0 private E 172 186 39 0 255 255 255 0 private SNMP Version vat v SNMP Write Community Admmistratrye Usename Starting IP Address Authentication Password Ending IF Address Encryption Password The network operator can set the Discover capability to search a specific subnetwork for panels or search across a range of IP addresses If appropriate you should take into account the VLAN IP address of the switch port when discovering the panel power midspan The two leftmost buttons on this Discover Devices window are used to select which type of Discover to initiate By selecting the top button the top half of the screen is then used to reguest a subnet search 22 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Subnet Search After selecting a Subnet option the Add Edit and buttons become active and give the network operator a chance to enter or modify the subnet information in the DPoE Element Manager prior to starting the Subnet search When Add is sel
55. itional 01 to 05 seconds elapsed time 06 to 10 seconds and then released a processor reset will be performed LED will flash fast green during this interval 3 Ifthe reset wire is actuated for an additional 01 to 05 seconds elapsed time 11 to 15 seconds and then released IP configuration will be cleared from memory and the processor will be reset This will force a DHCP initialization LED will flash fast amber during this interval 4 Ifthe reset wire is actuated for an additional 01 to 05 seconds elapsed time 16 to 20 seconds and then released SNMP community data will be cleared from memory and the processor will be reset LED will flash fast red during this interval 5 Ifthe reset wire is actuated for any additional elapsed time beyond 21 seconds and then released ALL memory data will be set to a factory default and the processor will be reset LED will be solid red during this interval Table 13 DPoE 1Gb Power Patch Panel Hardware Reset Sequence TT Elapsed Time in Initial Solid Red 00 05 Flashing Green 06 10 Flashing Amber DHCP Reset 11 15 Flashing Red SNMP Community Reset 16 20 Concluding Solid Red All FLASH data set to factory default 54 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F APPENDIX 1 BASIC TROUBLESHOOTING Use the following guide to help resolve problems installing the DPoE M Power Patch Panel If the problem persists contact PANDUIT Technical Support or a l
56. iv authNoPriv authPriv The following lists capabilities for each user Table 10 SNMPv3 Defaults and Access e mm ie 70 Password Version Authlevel Administrator setup_passphrase v3 authNoPriv ML LM S Maintenance setup_passphrase authNoPriv All All except panduitNetSNMP EM writecommunity ML ANN HFC 3418 E usmUserTable panduitNetSNMP ACMTable writecommunity Trap Settings The Trap Setting section allows the network operator to configure the DPoE M Power Patch Panel to send configuration and alarm messages to up to three different IP addresses IMPORTANT If one of the traps needs to be configured and set to the IP address of the computer running the DPoE Element Manager in order for the DPoE Element Manager to receive configuration and alarm messages from the panel Then the computer running the DPoE Element Manager should not have any other programs running that receive trap information The IP Address SNMP Weg scite Community String and Community String 7 v3 Types nf Traps to Send SNMP version normally Enable IP Address SMMPv3llsemame SNMP Seclev Critical Major Minor Advisory SNMP V3 are set according 72163757 puble az x m v F F to the destination device for 17216 38 12 public oc miram m iv 7 7 these outgoing messages 0 0 0 0 Doc Te cd Y The Enable provides an easy n 0 0 0 public e mag om a a g on off button for the traps 0 0 8 0 Doc M BEBEHB RE DU D without h
57. l appear requiring the previously saved panel port information from the Export exercise to be located and opened Import Port Look m se BM PRELUAD C M 3 efad7e9ni7ae47e324a05279c29285ab3 HP OV NNM Support oe 5 Sbabb1besefedesd7 7f di al 31386 My Recent 7320068 Perf review IBMTOOLS Documents 9 A Jack Files icons BISCI Meeting Notes Inetpub C D Test Folder C3IPAQ Ga Comnet Files C Japan Stuff Complete Release C3 javakit dist C3javakit old Documents and Settings C jdk1 2 2 Download 3 Linktest 3 Downloads Local Stuff DRIVERS mnt GR s 3MSOCache HP Files Cymspclnt iv FvEoEv o v v v 9 v A v A v 7 7 A Mu Network File name Places Files of type Panduit Element Manager pem M L ancel After opened there will be a delay as the panel information is written into the selected panel CAUTION No error checking is performed in a DPOE device If a device is selected incorrectly it is possible to overwrite a 24 port configuration information into an 8 port device only the data representing the first 8 ports will be used Conversely and 8 port device can overwrite information into a 24 port unit This may be desirable for device level configuration information e g owner location etc but may be undesirable for port information View Port Information In addition to the button on the tool bar which will display configuration i
58. lexibly assigned to any of the e mail addresses The E Mail Settings option under the Tools pull down menu provides an easy mechanism to add new e mail addresses to the system or administer which events trigger messages to which e mail accounts There is also a button ERI on the top tool bar on the system level opening screen to perform this task E Mail Settings E mail Enabled Source E mail Address Technician home com administrator desk gov 46 SMTP Server DPoE Power Patch Panel Undiscovered Panel Cold Start v Panel Agent Cold Start New Panel Discovered PD Connected PD Disconnected CI FD Fault v Panel Power Above Threshold Panel Power Below Threshold O Fuse Blown L Port Physical Location Changed C Panel Self Test Failed C Panel Self Test Passed C Trap Recipient Changed PD Detection Failure L Panel Agent Lost Communication IP Address Changed Low Panel Voltage High Panel Voltage Save Close PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Before any e mail messages can be sent from the system the SMTP Server and Source E mail Address fields must be entered The Source E mail Address will be used as the from address on all e mails sent from the Element Manager Once this information is added check the E mail Enabled box and store the settings using the button By clicking on the Add button the network operator can enter a de
59. m panel power set at different levels and therefore would alarm at different points refer to the Edit Panel Information section for more information on the Power Threshold field Hack Space Numbering is a system wide field Ascending Descending that enables the DPoE Element Manager to display the panels in the racks in the same fashion as they are wired in the network racks Either the rack slots are numbered from with the highest rack positions at the top Descending or the highest rack positions at the bottom Ascending By setting this parameter appropriately the rack level displays presented by the DPoE Element Manager will show the DPoE Power Patch Panels in their installed top to bottom order The SNMP Timeout Value is a configurable threshold If more than this number of seconds has expired and the system hasn t yet received an answer to a previously transmitted SNMP message the system will assume there is a communications problem DPoE Power Patch Panel Firmware Update The DPoE Power Patch Panel has the ability to have its firmware programmed remotely A Trivial File Transfer Protocol TFTP operation can be initiated using the DPoE Element Manager The Firmware Update option under the 7ools pull down menu provides a method to perform the update The latest version of firmware and updates may be downloaded after product registration at http www panduit com Support Software index htm An important feature of
60. manner It is highly recommended that the Network Administrator invest the effort to provision the DPoE device in the following manner 1 During the installation of each DPoE Power Patch Panel it is important to record the MAC address This is required because it is the only unique identification of the DPoE Power Patch Panel once it is placed into your network An installation worksheet is provided to record this and other important information A bar code of the MAC is also provided that allows a bar code reader to record this information automatically The MAC and bar code for the MAC are found on the rear of the DPoE Power Patch Panel near the management port 2 Once the DPoE Power Patch Panel is connected to the network and power is applied the DPoE Power Patch Panel will need to obtain an IP address a The DPoE Power Patch Panel can obtain an IP address via Dynamic Host Configuration Protocol DHCP This could take 1 2 minutes depending on your network and DHCP server settings b Orthe DPoE Power Patch Panel can be set to a static IP address In order to set the device to a static IP address you will need the following information 1 The desired static IP Address for the DPoE Power Patch Panel 2 The desired Subnet Mask for the device 3 The IP address of the desired Gateway for the device Panel IP Address SNMP Settings DHCP IPAddess T 72 16 29 151 r Panel Settings C Static Subnet Mask O55
61. me Port Message 40 1 5 2007 13 26 47 23 PD connected Class 0 Device Physical Location Messages this port Figure 9 View Individual Port Screen Clicking on the Edit button will bring up a screen to edit individual ports on a DPoE Power Patch Panel If the network operator were simultaneously configuring multiple ports the Multiple Port Edit screen would instead appear and any values not overwritten would be left unchanged Administration Control This setting ON OFF allows the network operator to control whether each individual port is sourcing PoE power If this field is set to off the port acts like any port on a non powered patch panel rather than a PoE port This enables the network operator to mix non powered or locally powered devices in the same panel as PoE devices The factory default setting for this field is ON Power Priority This setting Low High Critical indicates whether the importance of maintaining PoE power to this port in low power situations This field is used in coordination with a higher level Network Management System if available PD Type This free form field allows the network operator to enter information on the Powered Device PD such as the type of device IP phone camera etc PoE Power Mode These settings Normal Forced with check Forced indicate the power mode being delivered to a powered device In Normal mode the device port will deliver the standard IEEE 802 3af 2003 compl
62. n from an existing panel to a new panel is also available e Online Indicator This real time display indicates the communication status between the DPoE Element Manager and the DPoE Power Patch Panels Additions or Changes to UserName Password By adding additional UserNames to the DPoE Element Manager the network operator can allow access to the system via the DPoE Element Manager by other users without the need for sharing a single UserName Password among multiple users uses The Users option under the Tools pull down menu e provides an easy mechanism to add new or modify UserName Description UserNames There is also a button on the Administrator Default User top tool bar on the system level opening screen to Tech NE Region perform this task By clicking on the Add button the network operator can create new UserNames and Passwords for use the system A free form Description field is also available Maintenance of UserNames is done by first clicking an existing Username then clicking on ions Properties either the button to delete that L J UserName or the button to User Properties SEE have the following screen appear After any changes are made use the UserName Close button to return to the system level opening screen Description Password Reenter Password cues Passwords are case sensitive Users must enter the password exactly as the ne
63. n undefined ETTTTTTTTTO Export Log Power Supply Location Power Source Name not m Current Power Usage 2 View Entire Log The port information will be displayed for this example port 5 and the selected port will continue to be highlighted with the flashing yellow indication F Panduit Element Manager File Devices Tools Help e a ml alo si B Racks Rack Name undefined Rack Space Location 1 B Alpha Test Southeast Network B LAN BB Rack ID not set undefined em undefined am undefined mmm sa SYSNAME_April4 26 mmm undefined Device undefined IP Address 172 21 50 43 9 Rooms Panel undefined Port 5 Port Information 7 View Panel Info PD Type Administration Control Work Area Location Legacy Detection Disabled View All Port Info Power Priority PoE Power Mode PD Detection Status Delivering Power Power Pairs Control Ability False Power Classification Class 1 Power Pairs Spare Export Log Edit View Entire Log Figure 7 Active Port Indicator Screen The Port information and yellow indicator will remain until another port is selected or you navigate to another screen view in the EMS 32 TANDU Y Y NW WN HN a I WN Panel IP Address The DPoE Power Patch Panels come with a factory setting of DHCP address assignment After the panel is connected to the DPoE M Element Manager the network administrator may change this setting by
64. nformation for all ports on the specified panel the network operator may double click any port on the Visual Display of the Front Panel portion on the View Panel Screen to view the information for that port only 40 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Clicking the View Port Info button will display the following screen and allow the network operator to administer the ports on a given DPoE Power Patch Panel FP Panduit Element Manager File Devices Tools Help aj e aj alo sol 2 Rack Name TestLab Rack Space Location 1 Device DPOE MNS Testlab IP Address 192 168 0 129 All ports for DPOE MNS Test lab Port Information Port Port PD Type Power Priority Power Class Admin Control PD Detection Status Pow information Cr puis Non for all ports Cia pee Non on the selected Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Searching Norn Too bar Critical Searching Norn Critical Searching Norn tO CO I CD C Pi Co n2 Critical Searching Norn Critical Searching Norn Critical Searching Norn Critical Class 0 Delivering Power Norn Ec LUI MON View Panel Info Edit Port Properties Export Part Info View Entire L
65. ng information for the panel power midspan the DPoE M Element Manager may show a message indicating an SNMP Agent Error If this occurs retry the operation If this repeats it may be the indication of a slow network or a large number of concurrent operations in which case you may have to increase the timeout setting of the DPoE Element Manager located under the Tools section of the application If the panel oower midspan continues to fail to respond there may be a problem with the network connection itself The DPoE Element Manager reflects physical location information and power status based on the last time this information was refreshed In order to work with the latest physical location information and power status you should refresh the panel power midspan information using the Refresh icon on the Element Manager before making any modifications When the IP address of the panel power midspan is first assigned or is changed you may see the message The IP address has changed Do you want to commit this yes no when you are discovering the panel s power midspan s in your network Please select yes Once this change is committed you will not see this message again When using the DPoE Element Manager to change the network settings of the panel power midspan and you go from DHCP to static or static to DHCP you will lose communication with the panel power midspan until the panel power midspan is placed into a
66. o p SR DO dte d d muU Aces 31 Figure 7 Active Port Indicator SCTeEIl ue DD evo re pU eati Y ere 32 Figure VIew AIL POMS SCLC CN vices nue GY Deu Iu ee pace pex Eu He en E eU reu C ous 41 Figure 9 View Individual Port Screen amsn 42 Figure 10 View Message Log Screen sessssesssssessseeee nennen nnns 44 Figure 11 View Message Log Filter Parameter Screen eeeeeeeeseessss 45 List of Tables Table dep gekade oHIB RY _ yW Y 8 Table 2 Power Supplies Available from PANDUIT eeeeseeseeeeeeeeneee 9 Table 3 Recommended Strain Relief Bars Available from PANDUIT 9 Table 4 Color Coded Wire Positions for 802 3af 2003 Complaint Devices 12 Table 5 DPoE Power Patch Panel Power Up Sequence esses 14 Table G Panel Status VED TndieatlofiS eu d e D Ra FR One POR Euer OI OF 15 Table 7 Port Status WED IndieallollS miei eis eises ianea UN REP E entes ER EE Redux 15 Table 8 Network Status LED Indications eeeeeeeeeeeeeeeeeeeeeeeeeeee 16 Table 9 PC Minimum Requirements for DPoE Element Manager 17 Table 10 SNMPv3 Defaults and ACCESS cccccecccseceeececeeeceeeeceeeseeeeaueeseeseueeseeesaees 36 Table 11 DPoE Element Manager Log Messages c cccceecceeeceeeseeeeeeeaeeseeeeaeees 50 Table 12 DPoE Power P
67. oE Power Patch Panel User Manual Part Number PN439F TABLE OF CONTENTS SAFETY WARNING oto Gl me iu UE 1 WARRANTY eu 1 TRADEMARKS nu rm 1 OVEFRVIEW 2 eee ee eee eee eee eee 5 Features and BeneTllS oisi idet V obe ee vag areren gave vv dta erneten raat vd Rv evo 6 INSTALLATION m 8 Package Contents oie eii a do be BO OD DOL bd dd Ao 8 Panel MOUNTING Procedur6 ee Ge WD ber RD A ois 10 Hack Mounting InstrUctionS uei Gari Gei GAWR ber rl WR A R 10 Grounding FREGUIFGING ig uc erasian ENNYN ETOO 10 NebWork COMMCC HON cen Ginn ne ires pepe brsvupesu borde das od dw Mdd FUN DDIWEDD TN 11 Connecting the Powered Devices euuu i LL uu LLA LILI LL LLLA LLALL enne 11 Power Requirements eris ere vri tia iint T NA sind e Pow vicos Y BW SAN Pos GONE INC NW EARS 12 Powering Up the DPoE Power Patch Panel eseeese 13 OPERA HON oponen ed ce ene tcs cede A d E EIU M RD MET 15 EEDIDRdicatOr Sen Y Y 15 DPoE ELEMENT MANAGER SOFTWARE esee 17 Hardware and Software Reguirements ueuuuu eiu LY A LII LLI LL LLun 17 Installing the DPoE Element Manager Software 18 Connecting the DPoE Element Manager Host Computer to the DPoE Power Patch Panel naen ie wmv aaa aaa wala 19 DPoE Element Manager Operation u
68. ocal sales representative Table 14 Basic Troubleshooting Guide The panel status LED does not light when power The keyed power connector is not seated is applied to the unit properly Reseat the power connector No power is available at the panel Make sure the power supply is plugged in and operational The power connection may be bad Check the physical connection and make sure the voltage polarity is proper The power supply fuse may be blown Check the fuse The patch panel status LED is flashing green but The device is not connected properly to the no power is being applied to the connected DPoE Power Patch Panel Make sure that powered device s The port status LED over the the cable to the connected devices is properly port s where power should be provided is off terminated on the panel The cable is not punched down securely Re punch the 110 connections The attached power device is not 802 3af 2003 compliant or legacy Cisco compliant Make sure that the attached device meets either of these standards Also try to connect the device to another port to see if it powers on The port Administration Control setting is set to OFF in the DPoE Element Manager The DPoE Element Manager must be used to set the port Administration Control to ON refer to the Edit Port Information section for more information The panel status LED turns a solid red flashes The panel should be immediately disconnected red and
69. og Figure 8 View All Ports Screen Edit Port Information Clicking any row on the port information section of this screen will bring up the configuration information for that individual port This is the same screen that will appear by double clicking an individual port on the Visual Display of the Front Panel portion on the View Panel Screen By holding down the lt ctrl gt key the network operator can select multiple ports on the same Power Patch Panel Then by selecting the Edit Port Properties button on the Tool Bar network operator can configure multiple ports simultaneously Any fields not specifically overwritten with new values will be left unchanged 41 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F E Panduit Element Manager File Devices Tools Help 3 e Aj e vial 2 B B Rack Name TestLab Rack Space Location 1 est La mm DPOE MNS Test lab 2 Rooms Panouir S WR WPD PRUDD WRWRU Device DDOE MNS Testlab IP Address 192 168 0 129 Curent port CO nf ig u rati Part Information i View Panel Info on plus PD Type Administration Control ON E D IT Work Area Location Legacy Detection Enabled View All Port Info butto n Power Priority Critical PoE Power Mode Normal PD Detection Status Delivering Power Power Pairs Control Ability False Power Classification Class 0 Power Pairs Signal Export Log View Entire Log Msg t Date Ti
70. pply Location TRI In Desk Power Threshold 80 RW Enable Trap The DPoE Power Patch Panel name rack name rack space position and contact name should be entered here like the previous example The DPoE Element Manager will create a rack with that name and any device that has the same rack name will be grouped under that rack This Company Name Panduit Comp screen also includes a place to record the name Street Address 10500 W 167thSteet and location information of the power system for City Odand Pak this DPoETM Power Patch Panel 77 95 DR RR Country USA Note that the Panel Physical Location entry line Building Network Systems allows 1024 characters of information to be EN S C entered which includes additional physical and Y Roe 5 8 geographic information for this DPoE Power Patch Panel Fill out per the example shown on right Click the button and the Device Physical Location information will be added to the device attributes field 8 Once all of the desired information is entered into the Panel Attributes field click the button and this information will be saved The panel and the rack images will be shown in the DPoE Element Manager Tree View of the Network Area associated with the designated name 9 Other newly discovered panels can be provisioned by copying the Panel Attributes from this device and making changes where needed for the ne
71. rasing the entire log NOTE Clearing the log will clear the entire message log in the DPoE Element Manager It cannot be used to selectively clear a portion of the log 45 PANDUIT DPoE Power Patch Panel User Manual Refresh the Network The Refresh option under the Devices pull down menu or the button ah on the top tool bar provides an easy mechanism to make sure that the configuration and status information in a deployed network of DPoE Power Patch Panels is consistent with the DPoE M Element Manager Changes in network status or configuration changes made by a different DPoE Element Manager operating within the same network of panels are two reasons why panels may have different information than the DPoE Element Manager The Refresh capability will allow a Refresh of the entire network all the racks in a panel or a single panel within a rack Administering E mail Settings By using the E mail mechanism the network operator can assign specific e mail addresses to be notified of network Part Number PNA39F Refresh Refresh Selection All Panels C Panels in Selected Rack Selected Panel events For example the DPoE Element Manager can be configured to send e mail messages to one or more e mail addresses in the event of configuration changes incoming alarms or other events within the network of DPoE Power Patch Panels There are 16 categories of messages alarms and events which can be f
72. rd Power Prioritization using the DPoE Element Manager Easier Local Management using visual prompts Easier Remote Management using the bundled DPoE Element Manager Easier Installation 1 GbE data transmission rate 10 100 1000 The DPoE Power Patch Panel does not require the use of an internal fan Fans can reduce the system reliability Any port on the DPoE Power Patch Panel can support the 802 3af 2003 standard or the legacy Cisco In Line powering scheme By supporting both methods on each port the DPoE Power Patch Panel provides ultimate flexibility without the need for separate devices or power module adaptations for each powering scheme Devices that do not require PoE powering may also be mixed in the same DPoE Power Patch Panel In the event of a power lag or interruption a Network Management System NMS monitoring the DPoE Power Patch Panel can execute pre established port priorities to ensure mission critical ports on the network continue to receive PoE power as long as possible Multi colored LEDs on the DPoE Power Patch Panel allow technicians to instantly know the status of each port Additional LEDs indicate management and power midspan status Ultimate ID labels on the front the system allow the technician to note the device number the port number and wiring scheme information for both the Switch and Powered Device sides of the DPoE Power Patch Panel The DPoE Element Manag
73. rdingly PANDUIT Corp disclaims any and all liability arising out of the use of the products in any life support or critical application If buyer uses the product in any life support or critical application buyer and not PANDUIT Corp assumes full responsibility for such use Further PANDUIT Corp reserves the right to refuse to service any product used in any life support or critical application and disclaims any and all liability arising out of the PANDUIT S service or refusal to service such product The foregoing warranty shall not apply to defects resulting from buyer supplied firmware or unauthorized interfacing modification or misuse of the product operation outside of the environmental specifications for the product or improper or inadequate site preparation or maintenance by Buyer NO OTHER WARRANTY IS EXPRESSED OR IMPLIED PANDUIT CORP SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE REMEDIES PROVIDED HEREIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES PANDUIT CORP SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT OR OTHER LEGAL THEORY Unless otherwise specified by PANDUIT Corp opening of this product by unauthorized personnel will void this warranty TRADEMARKS DPoE and Ultimate ID are trademarks of PANDUIT Corp All other trademarks are the property of their respective owners PANDUIT DP
74. searched and click the button Check subnets to be searched EF Discover Devices Discover Devices By Subnet Web 255 255 255 0 private 172 16 38 0 299 255 255 0 private Edi 172 16330 255 255 255 0 private Remove SMMP Version SNMP write Community private Administrative Username Administrator Starting IP Address i Authentication Password Ending IP Address Encryption Password or Select Start to begin search When is selected the Scanning in progress dialog box will open showing the Subnet that is being scanned Scanning in progress 24 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F IP Range Search By selecting the bottom button on the Discover Devices screen the bottom half of the screen is then used to request an IP range search as part of the Discover Capability Select bottom button for Discovery By IP Address EF Discover Devices _ E X Discover Devices By Subnet 172 16 37 0 255 255 256 0 private r C 17216380 255 255 255 0 private l17216 32 0 255 255 255 0 private e Remove By IP Address SMMP Version v3 SNMP Write Community private Administrative Username Administrator Starting IP Address 172 16 37 D Authentication Password Ending IP Address 172 18 37 200 Encryption Password select SNMP version Starting and Ending IP address range and Select Start to initiate the provid
75. ssis ground 13 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Powering Up the DPoE Power Patch Panel 14 Plug the connector into the back of the DPoE Patch Panel 15 Once power is applied to the unit the DPoE Power Patch Panel will go through a power up sequence The following table describes the behavior of the unit as viewed from the front and the back Table 5 DPoE Power Patch Panel Power Up Sequence Behavior as viewed from the back of the unit Behavior as viewed from the front of the unit Both network status LEDs will light amber for two seconds The panel status Light Emitting Diode LED will light red for about 10 seconds After that a LED test seguence of the port status LEDs will take place The port will light red from the center to the outside then will flash green At that point all will turn amber for a short time and will then turn off If there is no cable connected to the IN management port Step 4 above both network status LEDs will turn off If the Patch Panel is configured for Dynamic Host Control Protocol DHCP address assignment default configuration and a cable is NOT connected to the IN management port on the rear of the panel the panel status LED will turn green If the DPoE Power Patch Panel is configured for DHCP address assignment default factory setting the network status LED above the IN management port will stay amber and
76. stination e mail address that will receive notification e mails when network events occur Add E mail Address h Once the e mail addresses are entered into the system and a specific e mail address is selected S men nec nre nens on the left panel of the E mail Settings the right panel is used to select which message categories will be sent to that e mail address refer to DPoE Element Manager Log Messages for more information on each of these message types NOTE The same category of events may be selected for multiple destination e mail addresses The Edit button is used to change the e mail address of an already assigned e mail address without the need to delete and reenter the selection criteria Search for Specific Panel s or Port s The Search option under the Tools pull down menu or the button 4 on the top tool bar provides an easy mechanism to search the DPoE Element Manager for specific panel s or port s NOTE The character may be used to perform wildcard searches The first screen to appear is the Panel Search option An alternate tab can be selected to perform a search for a specific port 47 PANDUIT DPoE Power Patch Panel User Manual FF Search Show All 1 Search For MAC Address f Show All _ Search For IP Address Device Search Parameters f Show All Search For Device Name f Show All Search Far Physical Location Se
77. system and port status through the use of LEDs on the front and rear of each panel There is one panel status LED on the front left of the panel 24 individual port status LEDs above each port and two network status LEDs on the rear of the unit These LEDs enable the technician to see at a glance if either the ports or the panel itself is in alarm refer to Figure 1 DPoE V Power Patch Panel Front View and Figure 2 DPoE M Power Patch Panel Rear View for a graphical view of the LEDs on the DPoE Power Patch Panel The following tables do not include the LED status during powering up the unit refer to Table 5 DPoE Power Patch Panel Power Up Seguence for more information on the LED indications during power up Table 6 Panel Status LED Indications LED Color Panel LED Description Status of Power Status Ports No Power is being supplied to the panel Power is NOT being delivered to the ports on the panel Green Flashing System operating normally Power may be delivered to the ports on the panel as configured Amber Solid Out of voltage range condition Less Power is NOT being than 46 VDC or more than 57 VDC is delivered to any ports being supplied to the panel on the panel Solid The main processor on the panel is Power may or may NOT operating properly and power may NOT be delivered to NOT be delivered to any ports on the any ports on the panel panel as configured Table 7 Port Status LED Indications LED Color Port
78. the Power Threshold allows the network operator to configure the available power for this panel as a percentage of the maximum power the panel can support For example although the panel can support 480 watts panels that use external power supplies rather than a direct 48 volt input are not normally capable of supplying 480 watts of power Therefore the Power Threshold for this panel might be set at 309e And the Power Warning Threshold which tells the panel when to send an alarm messages might be set at 10 so that the panel starts alarming when it reaches 90 of this particular panel s maximum refer to DPoE Element Manager Log Messages for more information on Power Warning Threshold The Enable Trap is a checkbox Id to quickly turn on off an individual panel s reporting of threshold power alarms 33 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F SNMP Settings The system defaults to public for the SNMP Read Community and private for the SNMP Write Community The SNMP Version Support can be selected to include v1 v2c v3 or v1 v2c or v3 There is an SNMPvsl button within the SNMP zug Senma settings section Communication Settings Selecting this SNMF Read Community public SNMP Version Support button will bring Up SNMP write Community private PIDAV3 SNMP wives v1 web the SNMPv3 dialog box Trap Settings SNMPv3 Settings i Communication Settings Adminis
79. the network status LED above the OUT management port will turn off This indicates that the panel is actively requesting address information from the network Once this information is received this could take up to a minute the network status LED above the IN management port will turn on or start flashing green as data is transmitted and received If the panel is set to static IP addressing rather than DHCP the network status LED above the IN management port will turn on or start flashing green as data is transmitted and received If the DPoE Power Patch Panel is configured for DHCP address assignment default factory setting the panel status LED will flash amber This indicates that the panel is actively requesting address information from the network Once this information is received this could take up to a minute the panel status LED will flash green refer to Figure 1 DPoE Power Patch Panel Front View and Figure 2 DPoE Power Patch Panel Rear View for a graphical view of the LEDs on the DPoE Power Patch Panel If the panel is set to static IP addressing rather than DHCP the panel status LED will flash green and continue flashing as long as power is applied to the unit NOTE For any troubleshooting issues refer to APPENDIX 1 BASIC TROUBLESHOOTING at the back of this user s guide 14 PANDU YW WN HN a NW a OPERATION LED Indicators The DPoE Power Patch Panel displays
80. the Log Messages from the currently selected port DPoE Compact 8 Midspan or the entire Messages to Export network of DPoE devices into an external file Export Messages All Messages The Export Log button on the tool bar on the View Panel Selected Rack Screen provides an easy mechanism to perform this task Selected Panel 43 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F View Entire Log The View Entire Log button on the tool bar on the View Panel Screen can be used to view log file Viewing the message logs can also be activated from most points within the DPoE M Element Manager using the button on the top tool bar P Panduit Element Manager File Devices Tools Help 3 e Aj ale 21d 2 Racks B Test Lab mm DPOE MNS Test lab ag Rooms Rack Name TestLab Rack Space Location 1 Device DDOE MNS Testlab IP Address 192 168 0 129 Message Log Message Date Time MAC Address IP Address Message Device Name Log area Tool bar for Log Messages 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 1 5 2007 13 26 47 13 25 12 13 22 09 08 53 30 08 53 28 08 24 59 08 24 55 08 24 52 08 24 48 08 24 44 08 24 40 08 24 37 08 24 33 08 24 30 08 24 26 08 24 23 08 22 25 08 22 22 08 22
81. trative Username Authentication Password Encryption Password optional lose Cancel This dialog box allows the user to enter the Administrative Username Authentication Password and optionally the Encryption Password in support of SNMPv3 IMPORTANT The SNMP Community fields are case sensitive and allow SNMP messages to be exchanged between the DPoE Element Manager and the DPoE Power Patch Panels FOR SECURITY REASONS THESE FIELDS SHOULD BE CHANGED FROM THEIR DEFAULTS SNMP Retry While running the DPOE Element Manager Software you may receive a timeout message o SNMP error with agent at 172 16 37 88 Timeout In certain network conditions you may want to select the number of times a SNMP message retry occurs prior to receiving this Timeout error message The SNMP Retry function enables a choice of the amount of times the SNMP message is retried 34 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F Once a device has been discovered the settings selections can be made from the pull down menu by choosing Tools and then Settings E Panduit Element Manager File Devices Mae Search View All Messages Filter Messages Export Messages Clear Messages Export Device Information Import Device Information Users E Mail Settings Firmware Update Settings Rack Name undefined Rack Space Location 1 beeees CeeTES TT ITI
82. turns to solid amber from power and then restored to correct The DPoE Power Patch Panel is providing The switch is not properly connected to the RJ power to the end device but there is no data 45 jacks on the front of the panel or the switch connection i e the Ethernet connection is not Check for proper connections and establish the working connections or reseat these if required The switch port may not be active Check with the local IT person to see if this is the case and correct it Punch the port s and test the connection again 55 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F APPENDIX 2 TFTP SERVER INSTALL There are many excellent TFTP Servers readily available on the Internet that run on all types of computer platforms Windows Linux DOS Mac etc Here is a list of TFTP servers that run on the Windows Operating System Vendor Price Link Solar Freeware http www solarwinds net products freetools index aspx TF TPServer Winds Weird Shareware http www weirdsolutions com weirdSolutions files products Solutions desktopSoftware desktopTftp tfto desktop free exe WinAgents 30 day http www winagents com en products tftp server index php Trial For this application note we will use the free Solar Winds TFTP server Go to the Solar Winds website listed in the table above and download the free TFTP server Go to the file SolarWinds TFTP Server exe and execute this install program
83. twork operator assigned it A user cannot delete a currently active UserName 21 PANDUIT DPoE Power Patch Panel User Manual Part Number PNA39F Panel Discovery Once the DPoE Element Manager is connected into the network the Discover capability can be used to find the deployed DPoE Power Patch Panels refer to Connecting the DPoE Element Manager Host Computer to the Host DPoE M Power Patch Panel for more information The DPoE Element Manager initiates messages into the control network and requests responses from any panels that see this message Unless the DPoE Power Patch Panel has been configured during installation using the DPoE Element Manager this Discover capability will only receive the configuration and existence of the DPoE Power Patch panels themselves The network operator will still need to enter port and rack information such as which racks the panels are wired into and where in each rack the panel is physically mounted The DPoE Power Patch Panel Installation Worksheet included with the product can be used to collect this information during installation When installing multiple DPoE devices simultaneously it is very important to record the MAC address for each panel Since multiple panels will return the same factory default settings to the Discover capability the MAC address which is written on a sticker on the back of each DPoE Power Patch Panel is unique and w
84. us LED Indications and Table 8 Network Status LED Indications for information on the LED Indicators FF Pandult Element Manager Pie Dewees Took ain Ae ee B et JEMNE Tel Device DPOE MNS Testlab IP Address 192 1563 0 129 Visual Geral nanan Forre Indole d T isplay of Communcshon Statue Ondine row Rating p y IPAdde s 1821881129 dedere E fro nt Perri inp Bus A AR OH Volts DHIE ri T Powers Input Bus R 0 Volks panel MAC Address DOC 1240 7 Power Thunzbeld xx Habes Veto 1 Thueshiold Mniifieetinn Trag Tmin Fiamwa Vernm Pandit Powered Paich P Pewert neisumpticer 24 Walis Lorksck Mame Joe Mach Messag es Phyacal Locale MMS TEST LAB gr E Powe Supply Location Rack DPOEPWREBT2UF 2 specific to this Cuarer Poner Usage 2k panel mmm ow Tm Pur em i Tool Bar oe FU corrected Clase U Dawe Piperca Lucalori 0 10 20 Xx 4p 5o 5 20 s x qu S 2007 132512 NA Location infomation changed Device Physicd Locason A MNS TEST Lad LO Wem AAA Device Agen Cold Stt TA Uan 1 FLU delechon oed lygu Dine Plea Localron LS m DES MA Dewce Agent Cold 5 1AE ROLES MA uisa pou bak thresh ni ME 7 DES mein Ub Eb FL decoded Llar U Dwyn Fyn Locale S200 Cee So d PO dicornrcbed Llar 0 Device FPhurical Location LO aes A PD imi Class Dl Dime Physical Location TA Umz444 oT FU decorre Llar ll Dwyros FTynca Luc iun LAST DE 10 PO daconnech
85. viduals panels within that rack When the operator selects an individual rack the DPoE Element Manager automatically displays the information for each DPoE Power Patch Panel within that rack in the List View area top right Likewise all log messages relating to that rack are automatically displayed in the Message Log area bottom right These messages indicate any conditions with the rack itself the DPoE Power Patch Panels on that rack or individual ports on individual panels within that rack 20 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F If the operator selects an individual panel from the Tree View of the network area a second screen which overlays the Message Log and List View areas allows the operator to configure and monitor a specific DPoE Power Patch Panel refer to Figure 4 View Panel Screen for more information In addition to the three areas on the system level opening screen the DPoE Element Manager provides the following conveniences on this system level opening screen e Tool Bars The most frequently performed actions are assigned buttons on the two tool bars to speed with assigning ports and panels adding users to the management system filtering incoming messages for trouble isolation etc e Pull Down Menus All functions available through the tool bars are also available through the pull down menus but in addition network wide functions such as copying panel informatio
86. w rack names rack positions device name etc This can be done by selecting the table row with the last provisioned DPoE device right clicking and choosing Copy Panel Select the next panel to be provisioned by highlighting the row of the panel right clicking and choosing Paste Panel All of the Panel Attributes will be applied to the new device Select Edit Panel and edit Panel Attributes and make the appropriate modifications 29 PANDUIT DPoE Power Patch Panel User Manual Part Number PN439F F Panduit Element Manager File Devices Tools Help B Racks BB Rack ID not set Refresh Edit Panel Copy Panel Delete Panel Del Export Panel Information 10 The previous step should be repeated for each panel in the network until all the panels have been provisioned Once this is done the DPoE Element Manager can easily manage all of the powered panels using the more intuitive physical location information that is stored in each panel Administering Port and Panel level Information The DPoE Element Manager makes it easy to administer the deployed network of DPoE Power Patch Panels When a specific panel is selected in the Tree Level View of the Network on the system level opening screen the DPoE Element Manager automatically retrieves the latest power and LED information from the selected panel and displays on the View Panel Screen refer to Table 6 Panel Status LED Indications Table 7 Port Stat