Intelligent GSM&PSTN Auto-Dial Alarm System
Contents
1. Note Each group of number could not exceed 15 digit Each group of number can save only as phone call number or sms number The panel will handle the numbers in serial order For example you set the first number as sms number and the second as phone number it will send sms before making alarm call Function Settings Phone Group 1 Phone Group 1 Phone Group 2 Phone Alarm gt Phone Alarm gt Phone Alarm gt SMS Alarm 1358888888 o 4 SMS Attention Number Setting SMS attention number means the number that will receive sms when the external power is cut off or recovered the system is armed or disarmed the telephone line has error etc The sms content will also be displayed on the screen This system can store 1 SMS attention number This number will not receive defense zone alarm sms Method enter SMS Setting menu delete the preset numbers and then input the number you want to set Save it then you will see AC Power Recover Arm Disarm SMS PSTN Off Battery Low volt and Sensor Low volt Press 4 6 to choose on or off System default off AC Power Recover when the external power supply is off more than 8 seconds the panel will send sms AC Power Fail when the external power supply is recovered for 30s it will send sms Alarm System AC Power On Arm Disarm SMS when system is armed or disarmed it will send sms Alarm System Armed Disarmed PSTN Off when t
2. GSM amp PSTN Alarm System A Intelligent GSM amp PSTN Auto Dial Alarm System 2 See 4 5 6 SG 1 859 eOmes Profile For a better understanding of this product please read this user manual thoroughly before using it GSM amp PSTN NES 2013 5 V1 0 alarm System A o CONTENTS l Function Instruction 1 ll Alarm Panel Introductton ees 2 DF THI ALI ZATION 2 sgegeeg ebe geg de ee a 4 IV Function Settings eee eee eee eee es 4 1 Enter Gettngs cece eens eens eens eeeeeees 5 2 TIME SONG e BEEN RENEERNENEAdE ee ENER SEN 5 3 Alarm Call amp SMS Number Geng 5 4 SMS Attention Number Gettinmg 6 5 Voice Recordimg 7 6 Atm Delay Setting csiccsivssnsensnnctacrsnasetnceetennaceeunenecsie 7 7 Alarm Delay Zetting 7 8 Timely Arm Disam ee ee eeeeeaeeeeees 8 9 Siren Setting for Alarm 8 10 VOICE op nesincera ged Ee 9 11 Ring Time Settings veces les agavalen eee eal eden ina aiia 9 12 Add or Delete Wireless Sensors ees 9 13 Defense Zone Geittng eee ee eeee eres 9 14 Alarm Center ZGeittng eee eeeeee tees 11 15 User Password cccceceeeeeeceeeeeeeeeeeeeeeaened 12 16 Program Password 12 17 Wireless Siren Geitng renerne 12 18 Record Checking eie aaea 12 19 Factory Reset aaaea 13 V Operation Instructon eee eee 13 1 Systemi Status secs iexgutie geed AER boats AEN RN 14 2 Remote Controller Operation 14 CONTENTS 3 a E EE 14 A let
3. 00 30 you want to set Press 8 to choose Pair you will see in paring At this time you can trigger the remote controller or sensor Please trigger it twice The screen will display operation ok after successful setting Choose Delete you will delete all the sensors in this chosen defense zone Zone No 13 Defense Zone Setting Enter Zone type menu then delete the previous zone number and input the number 01 34 you want to set Then you could do the settings Zone activate disable this means you want this zone work or not Defense line 0 24 hour defense zone 1 out arm zone 2 home arm zone O Function Settings 00 SOS help alarm information Alarm Delay Off On press 4 6 to choose to activate alarm delay function or not Zone Activate gt 0 Defense Line gt off 01 00 SOS Help gt Door Contact gt Ee off Alarm Delay off gt System default setting for all zones List 1 Zone number Zone type Zone on off Alarm delay 00 On Off 01 10 24 hour zone On Off 11 20 Out arm On Off 21 29 Home arm On Off 30 Doorbell zone On Off 31 34 Off Off List 2 Zone Alarm CID Zone Alarm CID No Information code No Information code 01 00 SOS Help E100 18 15 Glass Alarm E131 02 00 SOS Help E100 19 18 Garage Alarm E130 03 01 Panic Button E121 20 09OutArm E131 04 02 Panic Button E120 21
4. 19PIRAlarm E132 05 03 Fire Alarm E110 22 19PIRAlarm E132 06 03 Fire Alarm E110 23 19PIRAlarm E132 07 05 Kitchen Alarm E130 24 20 Living room E130 08 15 Glass Alarm E131 25 20 Living room E130 09 15 Glass Alarm E131 26 21BedroomAlarm E130 10 07 Tamper Alarm E137 27 21BedroomAlarm E130 11 10 Door Alarm E134 28 21BedroomAlarm E130 12 10 Door Alarm E134 29 18 Garage Alarm E130 13 11 Front Door E134 30 24 Doorbell 14 12 Back Door E134 31 10 Door Alarm E134 15 13 Side Door E134 32 09 OutArm E131 16 14WindowAlarm E131 33 09 OutArm E131 17 14 Window Alarm E131 34 19 OutArm E132 Function Settings 14 Alarm Center Setting Enter CMS Upload menu you can do all the following settings CMS No Setting this is the alarm center number this number could not exceed 15 digit User ID Setting delete the preset numbers and input the new ID 0001 9999 default 0001 Status Upload press 4 6 to choose on off Turn on this function the operation of arm disarm will be uploaded to the center System default is off AC Power Fail press ue to choose on off Turn on this function when the external power supply is off the panel will send information to the center System default is off Battery Low volt Turn on this function when the main panel battery is in low power the panel will send information to the center System default is off System default is off Sensor Lo
5. Care and Maintenance x Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or even melt some plastic parts x Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system Zb is recommended that you check and test the alarm system periodically Check the main unit every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally Check the SIM card 1 Check the use of SIM card such as network signal balance etc 2 Make sure the PIN code verification of the SIM card is closed 3 Please keep the password and SIM card number safe in case that other people remote control the system illegally Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket x Do not place the system near your bedroom or office table because the siren will make high loudness sound in
6. 30s you can press 1 2 4 And if there s no operation for 30s it will hang up automatically Press 4 Replays the pre recorded voice After this operation you can still press 1 2 3 Press Hang up the call Technical Parameters Vi Technical Parameters Main panel Input voltage DC12V 1 2A Standby current lt 560mA Alarming current lt 5600mA GSM band 850 900 1800 1900MHz Wireless frequency 315 433 868MHz default 433 Backup battery 3 7V 1200mA LI rechargeable battery Standby time 10 12hrs Recharging time 12hrs Working Temperature 10 C 40 C Humidity lt 90 no fog Wireless detectors 120pcs Vil Components List Main panel 1 pc Remote controller 2 pcs Siren 1 pc Wireless PIR sensor 1 pc Wireless door sensor 1 pc Telephone line 1 pe Power adapter DC 12V 1 2A 1 pc User manual 1 pc Vill Care and Maintenance The alarm system has excellent design and uses advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system Place the control panel and all parts and accessories out of children s reach Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged aaa 7
7. BEE 14 Bi DISA enee ere 15 6 Emergency Help 15 7 Answer Alarm Cal 15 8 Remote Zgpttok s ENEE 16 VI Technical ParameterS ccccsccseceseeeeeeenenseeeneeaes 17 VII Components List 17 VIII Care and Maintenance NNN NENNEN ENN 17 aaa S MA Function Instruction x x gt X Si X Touch keypad and large dot matrix LCD screen with perpetual calendar and detailed display GSM and land line PSTN dual network alarm Support 5 user alarm phone numbers call or sms 1 alarm center number and 1 SMS attention number 30 wireless defense zones and 4 wired zones each zone could be programmed individually including the setting of defense zone type sensor name bypass alarm delay Support the function of 10 second voice recording arm alarm delay 100 alarm and status records saving Arm disarm operation could be realized by main panel remote controller remote call sms and wireless keypad One relay output to control home appliance The alarm SMS content defense zone number sensor name SMS alert for arm disarm main panel battery low power external power off recovery phone line failure sensors low power Support Ademco contact ID Information that could be upload to the alarm center includes alarm arm disarm battery low power external power failure recovery period manual test and sensors low power x Compatible with all our accessories including digital video recorder wirele
8. MA Operation Instructions and user phone numbers If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you hang up directly without answering the call the system will call each preset number for 3 times circularly If you answer the call you will hear the pre record voice You can set system via your telephone or mobile phone keypad Press 1 Main unit stops alarming and Arm the call is hung up directly and it stops calling users Press 2 Main unit stops alarming and Disarm the call is hung up directly and it stops calling users Press 3 Turns the siren off and monitors the scene for 30 seconds Within the 30s you can press 1 2 4 And if there s no operation for 30s it will hang up automatically Press 4 Replays the pre recorded voice After this operation you can still press 1 2 3 Press Hang up the call and stops alarming Note the alarm SMS number will receive alarm message Alarm System zone number alarm type 8 Remote Control Dial the number associated to the alarm panel by phone mobile phone and after one ringing cycle you can hear a Di sound Then press user password A A Di sound indicates operation correct and now you can Press 1 out arm the call is hung up directly Press 2 disarm the call is hung up directly Press 3 monitoring for 30 seconds Within the
9. the case of alarm which may adversely affect your rest or work x If the alarm system will not be used for a long time please disconnect the system from the power supply x Please do not disassemble repair or alter the products without permission or it may cause accidents and faults Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages Care and Maintenance Care and Maintenance x Without approval and consent of relevant authorities please do not set 112 911 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service point for repair We will try our best to solve the problem for you as soon as possible The following accessories are optional geht ve z E i Wireless Outdoor Signal booster Wireless Keypad Flash Siren KS Door sensor Panic Button Remote controls an t d d 4g co i Smoke Detector Gas Detector PIR detector Optional sensors detectors are packed separately You can choose according to your specific requirements mee eo Wey 7 a ee
10. NO triggered input content 3 Press key numbers 2 8 4 6 to turn up down left right aT Q Function Settings 4 If there s no operation over 30seconds the panel would exit setting status automatically 1 Enter Settings Press amp then input the 4 digit program password and to enter setting status default password 1234 2 Time Setting After enter settings you could see clock setting Enter it to set the time and date The first group is for time hour minute second the second is for date month day year and the last is for day Please press SOS to clear the previous data and then input the correct data And finally press CH to confirm Operation figures Clock Setting Phone No setting 14 35 21 Sms Serring Voice Recording 05 01 2013 WED 3 Alarm Call amp SMS Number Setting This system can store 5 groups of alarm numbers When alarming it will make alarm call or send sms to these numbers And the call will be made in order for three times automatically until someone gets through it Method enter phone No setting menu choose Phone Alarm or press 4 6 to choose SMS Alarm Press and then delete the preset numbers Input the number you want to set Save it then you will see the phone group change to 2 automatically That means after setting a group of number successfully it will enter the setting of next number automatically
11. creen will display PSTN Off when the telephone line is cut off The panel will make two short beeps at the same time Arm amp Disarm Siren turn on this function the built in siren of the panel will make one short beep for arm operation and two short beeps for disarm 8 Function Settings Arm amp Disarm Horn turn on this function the extern siren will make one short beep for arm operation and two short beeps for disarm PSTN OFF Arm amp Disarm Siren Arm amp Disarm Hom 11 Ring Time Setting When you use phone to call the alarm system and do remote control it will get through after several rings This ringing times could be set 1 9 Method Enter Voice Prompt menu then set the times of Tel Ring Time and SIM Ring Time Tel Ring Time the ringing times when you call the landline number system default 6 SIM Ring Time the ringing times when you call the SIM card number system default 3 Tel Ring Times SIM Ring Times 6 3 12 Add or Delete Wireless Sensors This alarm system has 30 wireless defense zones each of which supports up to 4 wireless detectors And it supports up to 10 remote controllers Extra sensors and remotes have to be set with the alarm panel in order to perform normally Zone 00 is for remote controller and zone 01 30 are for wireless sensors Method Enter Pairing amp Deleting menu Delete the zone No and then input the number
12. etting If you want wireless sirens to work together with this alarm system you need to set them first Set the wireless siren into coding status refer to siren user manual and then press button SO on the main panel for 2 seconds The main panel will send wireless signal to the siren and the siren makes two beeps after receiving it The setting is successful and the siren could exit coding status 18 Record Checking In standby status pressing 0 button on the panel could check the Operation Instructions alarm and working record Press 4 16 to upturn or downturn This system can store 100 records The last status is ranked as the first record And when the record number exceeds 100 the most previous record will be deleted automatically 03 Working Log 07 Alarm Log Armed 00 Defense Zone SOS Help 01 01 09 37 AM 01 05 04 42 PM 19 Factory Reset When the system is unstable it is recommended to reset it In setting status enter Factory Reset menu and then press 4 6 to choose on And save this setting After this operation all the settings return to factory default and the alarm records would be all deleted Factory Rest V Operation Instructions 1 System status There are 4 statuses as following yx Arm away arm all detectors will be in working status yx Home Arm in arm status the defense zone which is set as Home Arm Zone will not make alarm when detectors are triggered
13. fter this setting when there is an alarm it will make call or send sms after the preset delay time system default 10s Alarm Delay 10 Function Settings 8 Timely Arm Disarm After this setting the alarm system will start arm status and disarm automatically at the preset time Method enter timely arm disarm menu You will see the screen displays like the following diagram SUN means Sunday Delete the preset time first and then input the time you want to set 00 00 24 59 After saving it will change to MON automatically That means after each successful setting it will change to the next day SUN MON Away Arm Away Arm 12 00 Home Arm Home Arm 21 35 Disarm Disarm 9 Siren Setting for Alarm The siren can be set on or off when there s an alarm Enter Siren Setting menu You will see Zone No Delete the preset numbers and input the defense zone number 00 34 you want to set Save it and then set the Siren Duration 00 59minutes Save it and then set the Built in Siren Press Th to choose on off Siren Duration siren ring time default 1minute Built in Siren the siren built in the alarm panel Zone No Siren Duration Built in Siren 10 Voice Prompt Enter Voice Prompt menu you can set these functions PSTN Off Arm amp Disarm Siren Arm amp Disarm Horn as on off PSTN Off turn on this function the s
14. he telephone line is cut for 5 seconds the panel will send sms Alarm System PSTN Off Battery Low volt when the main panel battery is in low power it will send sms Alarm System Low volt Sensor Low volt when the sensor PIR sensor door contact sensor battery is in low power it will send sms Sensor Low volt NOTE This version alarm system does not have sensor Low volt function Please kindly contact us if required SMS Phone No AC Power Recover Am Disarm SMS 13588888888 Off On gt Off On gt Function Settings PSTN OFF Sensor Low volt Off On gt Battery Low volt 5 Voice Recording Enter Voice Recording and press 4 6 to choose on Enter it you can start the 10 second recording After 10s it will exit automatically Press amp or can end the recording manually Receivers can hear this recording when there s an alarm call Voice Record Voice Record In Recording Time 10 6 Arm Delay Setting Enter Arm Delay menu Delete the preset time and input the time 00 59seconds you want to set After this setting when you arm home arm away arm the system it will enter arming status after the preset delay time system default 10s Arm Delay Second 7 Alarm Delay Setting Enter Alarm Delay menu Delete the preset time and input the time 00 59seconds you want to set A
15. only detectors in out arm zone and 24 hour zone will trigger alarm yx Disarm the system will not alarm when detector triggered except 24 hours defense zone yx System setting status In this status all defense zones will not alarm when detectors are triggered 2 Remote Controller Operation Users can use remote controller to set system as Out Away Arm Home Arm Emergency Alarm and Disarm Operation Instructions Out Arm Disarm Home Arm Emergency Alarm yx Out Arm Press button ye Disarm Press button tr Home Arm Press button ys Emergency Alarm Press SOS button system will alarm at once 3 0ut Arm It means to guard all around your house while everyone is going out all the detectors of the host are always working when the detector is triggered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Main unit operation Press button the system will enter arm status 10seconds later or after the delay time set by user Remote controller operation Press button on remote controller system will enter OUT ARM status SMS operation user password Default 1234 1 After the setting the panel makes Di sound and you will receive a SMS Alarm System armed LCD display Away Arm 4 43PM 01 16 13 WED 4 Home Stay Arm Home arm means part of the defense zones are in arm status When there s someone at home it is recommended for safety p
16. ss siren wireless keypad etc yx Support Ding dong doorbell function and alarm call has priority over normal phone call Function Instruction Alarm Panel Introduction Il Alarm Panel Introduction In order to make the main unit get the wireless signal well for all wireless accessories please put the alarm host at the central place of your defense area Make sure it s away from large metal objects and household appliances which may cause high frequency interference as well as barriers such as reinforced concrete wall or fire door etc Front schematic diagram Built in Siren _______ LCD Screen z 4 am Check Home arm o z i 6 _ _pisarm Out Arm Ij 6 d Set Return ei d Sr 8 soe SOS Delete MIC Leen Keypad Confirm LCD display GSM Level 99 GSM Signal Disarm Strength 8 32PM 05 01 13 WED Back schematic diagram SIM card slot SIM card Battery compartment H Alarm Panel Introduction Initialization KE Wire ports Keypad buttons instruction 8 out arm away arm PSTN line Phone set home arm disarm amp user password check the alarm working status record Press bh to upturn or downturn sos emergency alarm Indicating tone Keypad press one short beep Arm one short beep Out arm or alarm with delay one short beep per second Disarm two short beeps Telephone line error two shor
17. t beeps External power failure the screen will display AC Power Fail Battery low power one short beep NO COM V V Z4 Z3 Z2 Z1 Max AC250V 3A DC30V 3A Remote call the main panel So Shon beep Cach 3 Seconds after getting through 1 ON OFF Power switch PERNT 2 DC12V POWER Power adaptor port 12V 1 2A Ill Initialization 3 TEL OUT Connect telephone set 1 Put SIM card please insert a valid SIM card into the card slot A TEL IN Connect telephone line Please make sure the power is off 5 sim SIM card slot 2 Connect telephone line connect the telephone line in your house to 6 l 12V output positive Can connect wired sensor the port TEL IN There s a cable in the standard kit It could 7 l 12V output negative Can connect wired sensor connect your telephone set to TEL OUT 8 Z1 Wired sensor 1 zone number 31 3 Connect power use the power adaptor to connect the panel to 9 22 Wired sensor 2 zone number 32 external power supply 10 Z3 Wired sensor 3 zone number 33 4 Turn on the backup battery turn the power switch to ON 11 Z4 Wired sensor 4 zone number 34 12 V Negative of siren black cable IV Function Settings 7 L me of siren red cable Note 1 All the settings are found within the setting status 2 Press to enter confirm save amp to return and SOS to clear the Relay output It will be closed for 3 minutes when alarm is 15
18. urpose to OO E Operation Instructions enable some of the detectors such as sensors for door window balcony etc and disable the others such as sensors for the hall or some places easy to be triggered by person at home Main unit Operation Press button on keypad Remote Control Operation Press button on remote controller once LCD display Home Arm 4 45PM 01 16 13 WED 5 Disarm The purpose of disarming the system is to let it not in alert status One way is normal disarming after operation of arming and the other is to stop the main unit alarming After the operation of disarm all the defense zones except 24 hour zone shall not work Main unit Operation user password Remote Control Operation Press button on remote controller SMS operation user password Default 1234 0 After the setting the panel makes Di Di sound and you will receive a SMS Alarm System disarmed LCD display Disarm 4 46PM 01 16 13 WED 6 Emergency Help Sometimes there may be some accidents happening a senior person or child suddenly becoming ill or being in great pain a fire emergency burglar intrusion Press SOS button on keypad or SOS button on remote controller or wireless panic button the main unit will alarm and make calls to the preset user numbers 7 Answer Alarm Call When the main unit sounds alarm it will dial the preset alarm center aaa S
19. w volt Turn on this function when the sensors PIR sensor door contact sensor battery low power the panel will send information to the center System default is off This version alarm system does not have this function Please kindly contact us if required Manual test Turn on this function all the operations and settings of the main panel will be uploaded to the center System default is off Period Time 00001 99999minutes 00000 means off CMS No Setting User ID Setting Status Upload 075588888888 gt AC Power Fail Battery Low volt Sensor Low volt Manual Test Period Test Function Settings 15 User Password This password is used to disarm the alarm system by panel keypad This system supports 3 user passwords A B C Password A is also the remote call password Method Enter Password Setting menu Delete the previous numbers and input the new 4 digit password System default 1234 When users use these passwords to disarm there would be sms to distinguish them For example Disarm with password A XXXX alarm system A Armed XXXxX is the user ID refer to the part alarm center setting Password Setting 16 Program Password The program password is used to enter setting status The default is 1234 Users can change it Enter PIN Setting menu delete the previous numbers and input the new 4 digit password PIN Setting 17 Wireless Siren S
Download Pdf Manuals
Related Search
Related Contents
CALCULATING TIME RECORDER USER`S MANUAL Notice - Castorama Trane Fan-Powered Low-Height Parallel Installation and Maintenance Manual Toshiba B-EV4D - Labeldiscounter CommandCenter Secure Gateway Xerox Phaser 7800 User's Manual Manual del usuario de vívofit® - Digital Precision Systems Operating Instructions Copyright © All rights reserved.