Home
ED-15 User Manual - Eliminator Lighting
Contents
1. DMX address setting available on off power switch with power indicator LED indicators for 1 4 Channels Four 6A fuses for overloading protection 250V 5x20mm Every effort has been made to design dependability reliability and comfort into each unit New products are being designed constantly to meet the needs of both entertainment and the lighting industry We welcome your comments about our product and services It is both a privilege and a pleasure serving you General Instructions This is a compact 4 channel dimmer pack with some useful functions To optimize the performance of this product please read this manual carefully to familiarize yourself with the basic operations This manual contains important information for user please keep it well for future reference Warnings This unit must be earthed Do not make any inflammable liquids water or metal objects enter the unit There are no user serviceable parts inside Do not attempt to dismantle or modify the unit Any strong shocks or vibration may result in malfunction Repairs must be done by authorized personnel This unit must be operated by adults do not allow children to play with it A N Cautions When unpacking please check the unit is not damaged Should something wrong happen to this product contact the local dealer immediately e All rights reserved No part of the manual included with this product may be reproduced transmitted transcri
2. ED15 4 Channel Dimmer Pack 2 3 OUTPUT 5A CH TOTAL 15A MAX iminatorg 4 Channel Dimmer Pack Dipswitch11 Channel1 2 ON Dimmer OFF Switch Dipswitch12 Channel3 4 ON Dimmer OFF Switch AUTO MODE Dipswitch9 ON Dipswitch10 OFF Dipswitch 1 2 3 4 5 6 7 8 9 10 1 2 A DMX Address Setting D S AUDIO 1 4 2 4 4g Single t ives sag SENSITIVITY Power Speed Program Loop J indicator 1 2 3 45 6 7 8 910 1112 ON 9 ON RS Dipswitch3 OFF Dipswitch10 0FF CAADAOAGAOI Dipswitch 1 2 3 4 5 6 7 8 9 10 o 1234567 89101112P EMA SLAVE MODE T indicator Dipswitch10 ON 2 4 4 Single t Program Loop 4 CAUTION Analog input DC 0 10V Risk of Electric Shock DO NOT OPEN 1 DC 15V 500mA 5 Ground A A 1 Ground 2 NC 6 Channel 3 N ouvrez pas risque de choc lectrique 2 Data 3 Channel 1 7 Channel 4 Warning This unit must be grounded 3 Data 4 Channel 2 8 NC USER S MANUAL Features Thank you for your purchase of this product by Eliminator This ED15 unit features include 4 channel professional digital dimmer pack dual Edison sockets per channel 16 built in programs single loop programming available SLAVE AUTO and AUDIO function mode available DMX amp Analog Input Output connector All four channels are user assignable between Dimmer and Switch modes Ropelight connection provided Audio sensitivity adjusting knob
3. I S Switch Mode 2 Slave Mode dip switch10 ON Push the dip switch10 to the ON position to make the unit into Slave mode Dipswitch m 2 3 4 5 6 7 8 9 10 te eee EeREEE 16 32 64 128 256 Value DMX Address Setting As the above illustration shows user can use dip switches1 9 to set relevant DMX address When having finished your setting add up all the values of the ON switched dip switches the added value is the current DMX address For example If you push dip swich1 dip swich3 and dip swichd to their ON positions the current DMX address level is 21 1 4 16 3 Auto Mode dip switch9 ON amp dip switch10 OFF Push the dip switch10 to the OFF position and push the dip switch9 to the ON position to make the unit into Auto mode on C 2 3 4 5 6 7 8 9 10 a us i TERE Speed Program Loop 4 Operation Guide 3 Auto Mode dip switch9 ON amp dip switch10 OFF As the above illustration shows in Auto mode dip switch9 is on and dip switch10 is off Dip switches1 3 are used to select the Speed level Dip switches4 7 are used to select the Program Dip switch8 is used to select Single programming or Loop programming 16 programs in a loop 4 Audio Mode dip switch9 OFF amp dip switch10 OFF Push dip switch9 and dip switch10 to the OFF position to make the unit into Audio mode Dipswitch 1 2 3 4 5 6 7 8 9 10 ore eM Value oe al
4. HTIN Printed In PRC
5. Program _Loop As the above illustration shows dip switch9 and dip switch10 are switched to the off position in Audio mode Chasing speed is controlled by the bass music effect Dip switches4 7 are used to select the Program Dip switch8 is used to select the Single programming or Loop programming 16 programs in a loop 5 Notice Information e When in link only one ED15 unit can work in the Auto mode or Audio mode the other connected units in link must be operated in the Slave mode e Other types of DMX receiver should not be connected into the linked ED15 units or something wrong will occur to the connected DMX receiver e When each linked ED15 unit has received the linking signal or the DMX signal the corresponding LED indicator will blink in time When the signal go out the corresponding LED indicator will go out subsequently e This unit has been designed to be hung It is recommended that for safety purpose the unit should be properly mounted using a suitable hanging clamp and safety cable e The printings on the front panel of the unit give user important information for reference Technical Specifications Power Input AC 120V 50 60Hz 15A max Channel Output SA CH Total 15A max Fuse loading F6A 250V 5x20mm x4 Fuse electronic F1A 250V 5x20mm Dimensions 261x1 3x62mm Weignt apprOX setae saieeeeacemnsia cto denirarsa Nea iaaea eee 1 7 kg 24 004 1630 Rev 1 1 Eliminator All Rights Reserved LIG
6. bed or translated into any language in any form by any means without authorized permission Notice Specifications and improvements in the design of this product and the manual are subject to change without any prior notice Control and Functions 1 Front View 2 3 OUTPUT 5A CH TOTAL 15A MAX Eliminator 4 Channel Dimmer Pack Dipswitch11 Channel1 2 ON Dimmer OFF Switch 4 Dipswitch12 Channel3 4 ON Dimmer OFF Switch AUTO MODE Dipswitch9 ON Dipswitch10 OFF 4 1 Dipswitch 1 2 3 4 5 6 7 8 9 10 i H On 5 2 Off _ eee eo nie an Be Singlet 4 Speed Program Loop 4 AUDIO MODE i ON RS Dipswitch9 0FF Dipswitch10 OFF 6 Dipswitch 1 2 3 4 5 6 7 8 9 10 e e SLAVE MODE Dipswitch10 ON nd amp ator in ax 1 alue Or Program Loop 4 CAUTION Analog input DC 0 10V Risk of Electric Shock 54 1 DC 15V500mA 5 G fel 5 m Groun DO NOT OPEN 3 2 NC 6 Channel 3 7 N ouvrez pas risque de choc lectrique Datat 3 Channel 1 7 Channel 4 Warning This unit must be grounded Data Se 4 Channel 2 i 1 Output There are 4 dual Edison sockets for channel output Up to 5amps can be connected to each channel 2 Power indicator When this unit is powered on this LED indicator will be lit 3 DMX indicator When there is any DMX signal input this LED indicator will be lit 4 Mic With a built in microphone inside this hole 5 Channel in
7. dicators 1 4 To indicate the input of 1 4 channels respectively 6 Audio sensitivity adjusting knob To adjust the audio sensitivity level as user s desire 7 Dip switches 1 12 To select desired function mode or set relevant parameters by using these dip switches see the operation guide for details Control and Functions 2 Side View POWER INPUT POWER DMX OUT PANSY N oken iN y mele AC 120V 50 60Hz 15A Max AJ e7 D 0 N T J z P 2 High Voltage Don t Touch ab AGE Fuses F6A 250V 5x20mm Load x4 ROPELIGHT s F1A 250V 5x20mm Electronic CONNECTOR L 8 9 10 11 12 13 14 8 Power input AC 120V 50 60Hz 15A Max 9 Power switch To turn on or turn off the main power 10 DMX IN To input DMX signal via this connector 11 DMX OUT To output DMX signal via this connector 12 Analog In To input analog signal via this connector 13 Analog Through To send out analog signal through this connector 14 Ropelight connector Used to connect with the rope lights Operation Guide 1 Dimmer Switch Mode dip switch 11 12 ON Push the dip switch11 to the ON position to make the unit into Dimmer Mode for Channel1 2 the OFF position into Switch Mode Dimmer Dimming Enable Switch Dimming Disable And push the dip switch12 to the ON position to make the unit into Dimmer Mode for Channel 3 4 the OFF position into Switch Mode Di itch 3 page D Dimmer Mode Off