Home

New Product Release

image

Contents

1. GX Developer Host computer MELSECNETHH Ethernet etc Redundant power supply system L inl E Checking to determine if a CPU model supports these new functions The module serial No and function version code are indicated on the rated plate located on the module s side face Check the first 5 digits of the CPU serial No and check the function version code The CPU supports MELSEC Q these new functions if its 5 digit No and code MITSUBISHI passe match or follow the Nos and codes listed below PASSED High performance m P MODEL Serial No first 5 digits eee eG edeheery Function version code SERIAL ncn ee ee ee en T er eS aa MITSUBISHI ELECTRIC MADE IN JAPAN Standards compliance marks are indicated here 2 PLC CPU High Performace Model QCPU Product name Model Model code Q02CPU program capacity 28K steps number of I O points 4096 Q02CPU 1W4A20 QO2HCPU program capacity 28K steps number of I O points 4096 QO02HCPU 1W4A30 QO6HCPU program capacity 60K steps number of I O points 4096 QO6HCPU 1W4A31 Q12HCPU program capacity 124K steps number of I O points 4096 Q12HCPU 1W4A32 Q25CPU program capacity 252K steps number of I O points 4096 Q25HCPU 1W4A33 Process CPU Product name Model Model code Q12PHCPU program capacity 124K steps number of I O points 4096 Q12PHCPU 1W
2. Sampling trace data can be saved in the standard RAM Sampling trace function User program execution sampiind gt Sampling trace results _ Sampling trace setting Using this new function does away with the need of using a memory card Previous systems required an SRAM card for saving sampling trace data but the new standard RAM format permits the selection of an ATA card or Flash card in accordance with the application and purpose in question Sampling trace results Standard RAM Power supply module errors can Power supply module 3 elm proved System Rel lability be checked from GX Developer s errors can be checked by system monitor SM SD readout Power supply error detection function has been added for redundant power supply systems System Monitor Alarm Display System XX failure detected at extension stage 1 base unit s power supply module 2 When a power supply error is detected at a redundant power supply system this new function saves the detection results in a special relay and register thereby permitting the creation of an alarm circuit in the sequence program Moreover the detection results can also be checked in GX Developer s system monitor This function can be used to improve system reliability both generally and from a preventive maintenance viewpoint This function is already supported by all QnPRHCPU models
3. 4A51 Q25PHCPU program capacity 252K steps number of I O points 4096 Q25PHCPU 1W4A50 Redundant CPU Product name Model Model code Q12PRHCPU program capacity 124K steps number of I O points 4096 Q12PRHCPU 1W4A52 Q25PRHCPU program capacity 252K steps number of I O points 4096 Q25PRHCPU 1W4A53 Manual name Manual supply status IB SH No Model code QCPU User s Manual Function Explanation Program Fundamentals Sold separately SH 080484ENG C 13JR74 QCPU User s Manual Hardware Design Maintenance and Inspection Sold separately SH 080483ENG C 13JR73 QCPU User s Manual Multiple CPU System Sold separately SH 080485ENG B 13JR75 QnPRHCPU User s Manual Redundant System Sold separately SH 080486ENG A 13JR76 QCPU Q Mode QnACPU Programming Manual Common Instructions Sold separately SH 080039 J 13JF58 QCPU Q Mode QnACPU Programming Manual SFC Sold separately SH 080041 F 13JF60 QCPU Q Mode Programming Manual MELSAP L Sold separately SH 080076 F 13JF61 GX Developer Version 8 Operating Manual Sold separately SH 080373E G 13JU41 Country Region Sales office Tel Fax Country Region Sales office Tel Fax U S A Mitsubishi Electric Automation Inc Tel 1 847 478 2100 Taiwan Setsuyo Enterprise Co Ltd Tel 886 2 2299 2499 500 Corporate Woods Parkway Vernon Hills IL 60061 Fax 1 847 478 2396 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Fax 886 2 2299 2509 Brazil MELCO TEC Rep C
4. E Changes for the Better July 2005 New Product Release No 242E ALITTI Q02 Q02H QO6H Q12H Q25H High Performance Model QCPU Q12PH Q25PH Process CPU Q12PRH Q25PRH Redundant CPU New Q Series CPU functions take functionality and reliability to the next level Point Increased functionality New SFC active step comment readout instruction More flexibility in multiple PLC shared memory refresh settings New clock data readout in 1 1000 secs units instruction Point2 Enhanced Debugging Sampling trace data can be saved to standard RAM Point 3 Improved System Reliability Power supply error detection function has been added for redundant power supply systems 1 To determine if a CPU model supports these new functions use the check method given on page 2 2 Must be used in combination with GX Developer Ver 8 24A or later Mitsubishi Electric Corporation Nagoya Works is a factory certified for 15014001 standards for environmental management systems and ISO9001 standards for quality assurance managememt systems ANI pore ZATIOy 14001 gt we ay Nannu N KA QUALITY MANAGEMENT E pin 3 Q Z w UKAS ENVIRONMENTAL MANAGE o MENT Meera pyre EC97J1113 Features 1 e Increased functionality New instruction S P SFCSCOMR S P SFCTCOMR Active step comment readout New SFC ac
5. ared a 1 axis JOG speed 1 axis JOG speed memory 7 setting register setting register 4 s 2 axis JOG speed 2 axis JOG speed ttii ist tt ist Device name assigned to setting register setting register the transmission range l eee pase ees lanual pulser 2 permissible lant ulser rmissible differs from that assigned flag set requests flag set requests to the reception range PLC No 1 PLC No 2 motion CPU New clock data readout in 1 1000 secs Sequence program Device memory Error detection units instruction sequence amp A a a Raen detection interval A new instruction permits clock data readouts from Bror Si 2005 5 22 1 sec to 1 1000 sec units Previously readouts 22 16 30 130 Error B were only possible in 1 sec units making it difficult TEE to identify the short time sequence of events leading Error B duane peton to a failure The new 1 1000 sec units readout detected 2005 5 22 simplifies the troubleshooting when the error occurs 22 16 30 050 in a very short space of times Error A Error C Error C detection rror undetected date time 590ms Error D Error D detection s Error D date time Newly added instructions 2005 5 22 detected 05 S P DATERD S P DATE S P DATE 22 16 30 720 Even if multiple errors occur within the same 1 second period their detection sequence and intervals are accurately recorded 2 Enhanced Debugging
6. om e Assessoria Tecnica Lida Tel 55 11 5908 8331 Taiwan Rua Correia Dias 184 Edificio Paraiso Trade Center 8 ander Fax 55 11 5574 5296 Korea Mitsubishi Electric Automation Korea Co Ltd Tel 82 2 3660 9552 Paraiso Sao Paulo SP Brazil Dong seo Game Channel Bldg 2F 660 11 Deungchon dong Fax 82 2 3664 8372 Germany Mitsubishi Electric Europe B V German Branch Tel 49 2102 486 0 Kangseo ku Seoul 157 030 Korea Gothaer Strasse 8 D 40880 Ratingen GERMANY Fax 49 2102 486 7170 Singapore Mitsubishi Electric Asia Pte Ltd Tel 65 6470 2460 U K Mitsubishi Electric Europe B V UK Branch Tel 44 1707 276100 307 Alexandra Road 05 01 02 Fax 65 6476 7439 Travellers Lane Hatfield Herts AL10 8XB UK Fax 44 1707 278695 Mitsubishi Electric Building Singapore 159943 Italy Mitsubishi Electric Europe B V Italian Branch Tel 39 039 60531 Thailand F A Tech Co Ltd Tel 66 2 682 6522 Centro Dir Colleoni Pal Perseo Ingr 2 Fax 39 039 6053312 896 19 20 21 22 S V City Building Office Tower 1 Floor Fax 66 2 682 6020 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy 12 Rama Ill Rd Bangpongpang Yannawa Bangkok 10120 Spain Mitsubishi Electric Europe B V Spanish Branch Tel 34 93 565 3131 Indonesia Pel Autoleknindo SUMBER MAKMUR elt bere 16S 068 Carretera de Rubi 76 80 Fax 34 93 589 2948 Muara Karang Selatan Block A Utara No 1 Kav Fax 62 21 663 0832 E 08190 Sant Cugat del Valles Barcelona Spain NO 11 Ka
7. tive step comment readout by new instruction instruction Readout comment display The SFC active step s transition conditions comment can be read out and displayed at GOT etc for easy checking and monitoring of the machine operating status Current process Material A positioning Material B machining More flexibility in multiple PLC shared memory refresh settings 1 Random settings 2 Motion CPU settings Previously refresh settings were possible only by assigning The refresh device range can now be specified in any continuous device ranges The new function permits 1 to 4 desired order refresh settings with the first device and number of points This is useful for the motion CPU where the device memory set specifically to each PLC map is stagnated Device Nos which are same as the motion CPU can be handled PLC No 1 PLC No 2 Shared Device memory Shared memory memo 1 axis current feed 1 axis current feed value value 7 Ha D1000 Data transmitted 1 axis actual current 1 axis actual current from PLC No 1 E value value E eoa o i Logo w E 0 Data transmitted 32 axis movement 32 axis movement a amount js amount change regi from PLC No 2 E nange Oe os register E 32 axis actual position 32 axis actual position W100 at STOP input D639 at STOP input Data transmitted PLC No 3 a from PLC No 3 Sh
8. wasan Industri Pergudangan Jakarta Utara 14440 France Mitsubishi Electric Europe B V French Branch Tel 33 1 5568 5568 India Messung Systems Pit Ltd Tel ett 20 27 2 3130 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Fax 33 1 5568 5685 ee iat NO 111 Unit No15 M I D C Bhosari Pune Fax 91 20 2712 8108 India South Africa Circuit Breaker Industries LTD Tel 27 11 928 2000 if ji KSR T 5 Private Bag 2016 1600 Isando Tripswitch Drive Elandsfontein Fax 27 11 392 2354 Australia Mitsubishi Electric Australia Pty Ltd Tel 61 2 9684 7777 Gauteng South Africa 348 Victoria Road Rydalmere N S W 2116 Australia Fax 61 2 9684 7245 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd Tel 852 2887 8870 10 F Manulife Tower 169 Electric Road North Point Hong Fax 852 2887 7984 Kong China Mitsubishi Electric Automation Shanghai Ltd Tel 86 21 6475 3228 1 3 F Block5 103 Cao Bao Road Shanghai 200233 China Fax 86 21 6474 6996 sa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADAMINAMI 5 HIGASIKU NAGOYA JAPAN 0507 MDOC Specifications subject to change without notice Printed in Japan on recycled paper

Download Pdf Manuals

image

Related Search

Related Contents

InVols software user manual Menu bar items  Operator`s Safety and Service Manual RAMMERS    Philips Streamium WAS5 User's Manual  en version pdf  BeBook Live 4GB Black  取扱説明書 - トーヨーキッチン    

Copyright © All rights reserved.