1. Open the clamp levers 1 of the luggage carrier bracket 2 Slide the luggage carrier forward or backward or remove it 3 Close the clamp levers of the luggage carrier bracket 1529686 R Accessories 27 Invacare Storm Series 5 Adjusting the mobility device to the user s seating posture 5 1 General information on adjusting the wheelchair to the user s seating posture CAUTION A N Damage to mobility device and accident hazard It is possible that collisions can occur between mobility device components due to various combinations of adjustment options and their individual settings The mobility device is fitted with an individual multiply adjustable seating system including adjustable legrests armrests a headrest or other options These adjustment options are described in the following chapters They are used to adapt the seat to the physical requirements and the condition of the user When adapting the seating system and the seat functions to the user ensure that no mobility device components collide Initial setup should always be done by a healthcare professional Adjustment by the user is only recommended after they have been given appropriate guidance by the healthcare professional o 9 Electrical adjustment options I Please refer to the user manual for your remote for more information on operating electrical adjustment options 28 i Recaro seats and AJ Optimist seats For more i
2. Invacare Storm Series A 86 CAUTION There is a risk of injury if the mobility device is not properly secured during use as a vehicle seat If possible the user should always leave the mobility device to use a vehicle seat and the safety belts provided with the vehicle The mobility device should always be anchored facing in the transport vehicle s intended direction of travel The mobility device must always be secured in accordance with the mobility device and anchoring system manufacturers user manual Always remove and secure any accessory parts fixed to the mobility device such as chin controls or tables If your mobility device is fitted with an angle adjustable backrest then it must be placed in an upright position Fully lower elevated legrests if fitted Fully lower the seat lifter if fitted CAUTION Risk of injury exists if a mobility device that is not fitted with leak proof batteries is transported ina vehicle Only ever use leak proof batteries CAUTION Risk of injury or damage to the mobility device or to the transporting vehicle if the legrests are ina raised position while the mobility device is used as a vehicle seat Always completely lower height adjustable legrests if fitted In order to use a mobility device as a motor vehicle seat it needs to be fitted with attachment points to enable anchoring in the motor vehicle These accessories may
3. 24 NOTE speed limiter The lifter is fitted with sensors which reduce the mobility device speed as soon as the lifter is raised above a certain point This takes place to guarantee the tipping stability of the mobility device and to avoid damage to the legrests If the speed limit is activated a corresponding blink code is displayed on the remote or a reduced drive level is set automatically Please refer to the remote manual for more information To reapply normal speed run the lifter down until the status display stops blinking CAUTION Risk of tipping if the speed limiter sensors fail when the lifter is raised If you find that the speed reduction function is not working when the lifter is raised do not drive with the lifter raised and immediately contact an authorized Invacare dealer 1529686 R 4 Accessories 4 1 Postural belts A postural belt is an option which can either be fixed to the mobility device ex works or can be retrofitted by your specialist dealer If your mobility device is fitted with a postural belt your specialist dealer will have informed you about fitting and usage The postural belt is used to help the mobility device user keep an optimum sitting position Correct use of the belt assists the user in sitting securely comfortably and well positioned in the mobility device especially for such users who do not have such a good sense of balance while sitting o We recommen
4. 4 Re insert screw 5 Re tighten the screws 44 5 7 6 Adjusting the backrest angle Modulite seat unit CAUTION A Every change to the seat angle and the backrest angle alters the geometry of the power wheelchair and affects its dynamic stability For more information on stability overcoming obstacles correctly driving along inclines and slopes and the correct position of the backrest and seat angles see the section 6 5 Taking Obstacles page 74 and Driving up and down gradients CAUTION Risk of falling out of the wheelchair When adjusting the backrest it might move backward unexpectedly and you might fall out of the wheelchair Do not rest against the backrest while adjusting it i If the backrest is fitted with knobs instead of Allen screws you do not need tools Width adjustable backrest 2 Tools ol e 5 mm Allen key 1529686 R On both sides loosen and remove the upper backrest screw Set the required backrest angle in 7 5 steps Use scale on the backrest for this purpose Ensure that you set the same angle on both sides 3 Re insert and tighten the screw Ensure you insert the screw through one of the holes of the backrest bracket The screw must be visible on the inside of the bracket and the screw head must be flush with the bracket Simple backrest Tools 9 ol 1529686 R 6 mm Allen key Adjusting the mobility device to the user s seating posture On both
5. Technical data ISO 7176 15 Seat type Curb weight e at least 174 kg Component weights Batteries e approx 24 5 kg per battery Payload Max payload Axle loads Max front axle load e 200 kg Max rear axle load e 300 kg IPX4 classification means that the electrical system is protected against spray water 2 Static stability according to ISO 7176 1 9 15 8 Dynamic stability according to ISO 7176 2 6 10 5 1529686 R 107 Invacare Storm Series 3 Note The drive range of a mobility device is strongly influenced by external factors such as the speed setting of the wheelchair the charging state of the batteries surrounding temperature local topography road surface characteristics tire pressure weight of user drive style and use of batteries for lighting servos etc The specified values are theoretical maximum achievable values measured according to ISO 7176 4 Measured without seat cushion Distance between backrest reference plane and most forward part of armrest assembly Horizontal distance of wheel axle from intersection of loaded seat and backrest reference planes Dependent on the seat dimensions See the manufacturer s data on www ajstole dk oO N DO WN A The actual curb weight depends on the fittings your mobility device has been supplied with Every Invacare mobility device is weighed when leaving the works Refer to the nameplate for the curb weight including batteries measured 108 1
6. if installed is adjusted so you can look behind at all times without having to bend forward or shift your seating position 6 3 Parking and stationary When parking your vehicle or if your vehicle is stationary for a prolonged period Switch the vehicle s power system off ON OFF key 2 Activate your anti theft lock if existing 6 4 Getting in and out of the mobility device The armrest must be removed or swiveled up in order e to get into or out of the mobility device from the side 6 4 1 Removing the standard armrest in order to side transfer DDS i Pull the plug of the remote cable to disconnect the remote 2 Loosen wing nut 3 Remove the armrest from the holder 73 Invacare Storm Series 6 4 2 Information about getting in and out WARNING Risk of serious injury or damage Improper transfer techniques may cause serious injury or damage Before attempting transfers consult a healthcare professional to determine proper transfer techniques for the user and type of wheelchair Follow the instructions below i If you do not have sufficient muscle strength you should ask other persons for help Use a sliding board if possible Getting into the mobility device Position your mobility device as close as possible to your seat This might have to be done by an attendant 2 Align casters parallel to the drive wheels to improve stabilit
7. o Tools e 6mm Allen key Switch the power supply off ON OFF key Unscrew Allen screws 1 Adjust the seat angle by raising or lowering the seat Insert the Allen screws again and tighten RWN 42 5 7 Adjusting the backrest CAUTION A N Adjusting the seat tilt or the backrest angle changes the geometry of the mobility device and directly influences its dynamic stability For details regarding dynamic stability negotiating gradients and obstacles and the correct adjustment of seat tilt or backrest angle refer to 6 5 Taking Obstacles page 74 and Driving up and down gradients 5 7 1 Electrical Consult the user manual for your remote for information about electrical adjustment 5 7 2 Adjusting the backrest standard seat manually with handscrews Si ORS Aa g Be E NA 1529686 R Remove the screws I on both sides of the backrest that hold it in position 2 Set the backrest to the desired angle by selecting a combination of one of the two holes in the backrest frame and one of the six holes in the metal fixation plate 3 Re position screws and tighten them 5 7 3 Adjusting the back seat angle on the Easy Adapt seating system Adjusting the mobility device to the user s seating posture gt Loosen the backrest plate screws and Do not remove the screws 2 Move the backrest plate to the required height 3 Re tighten the screws Adjust the angle by turning the han
8. 28 5 2 1 Adjusting the remote for the length of the user s QUIN 2i he bon deh eda EEE E E antem Ais 29 5 2 2 Adjusting the height of the remote only for swing away remote supports 2 29 5 2 3 Swivelling the remote to the side 29 5 3 Adjustment options for standard armrests 29 5 3 1 Changing the arm support position 29 5 3 2 Setting the height of the armrests 30 5 3 3 Adjusting the width of the armrests 30 5 4 Adjustment options for parallel sliding armrests 3 5 4 1 Setting the height of the parallel sliding armrests 3 5 4 2 Adjusting the angle of the armpad on the parallel sliding ALMNreStss ets 8 eed Oi Moats bh 3 5 4 3 Adjusting the width of the parallel sliding armrests 31 5 4 4 Adjusting the mobility of the parallel sliding arC Se oi eek beg 2 oto ee Se eee es 32 5 4 5 Adjusting the arm support positions for the parallel sliding armrests oree 5 eas Ro Ree ee ed 33 5 5 Adjustment options for the Modulite seat unit 34 5 5 1 Adjusting the height of the armrests 34 5 5 2 Adjusting the width of the armrests 34 5 5 3 Adjusting the position of the armrest in depth 35 5 5 4 Adjusting the height flip up armrest 35 5 39 5 5 6 5 5 7 Adjusting the height following armrest Changing the resistance flip up following armrest Adjusting th
9. 5 Adjusting the height of the calf pad 70 5 18 6 Unlocking and swivelling the calf pad backward when alighting 02 e eee eee eee 70 5 18 7 Adjusting the angle adjustable foot plate 7 5 18 8 Adjusting the angle and depth adjustable foot plater aiid usere nsee aa a ate he Se eres 7 5 19 Angle adjustable footboard 06 72 5 20 Adjusting the width of side mounted legrests 72 Usare tere 2 a tint eae eee EN 73 Galt DAVNE owe oes sei eae Be ae Fee Ae eee 73 6 2 Before driving for the first time 2 73 6 3 Parking and stationary 02 0 eee eee eee 73 6 4 Getting in and out of the mobility device 73 6 4 1 Removing the standard armrest in order to side LE ANS E ork hs ae Sco EI ee ee eee Ha 73 6 4 2 Information about getting in and out 74 65 Taking Obstacles snc3 bia ods e tae see gases 74 6 5 1 Maximum obstacle height 200 74 6 5 2 Safety information when taking obstacles 74 6 5 3 The correct way to overcome obstacles 75 6 6 Driving up and down gradients 06 75 6 7 Using foldable antitippers 22 202 eee 76 6 8 Use on public roads a eee ee ee es 77 6 9 Pushing the mobility device in freewheel mode 71 6 9 1 Disengaging motors conventional motors 77 6 9 2 Disengaging the motors True Track Plus MOOS 5 it chek Da hy does deh s
10. Loctite 243 a aed i N 10 II 2 3 Remove the valve cap Let the air out of the tire completely by pressing the pin in the centre of the valve in Remove the 5 Allen screws 1 Take the tire and the inner tube off of the rim halves Repair the inner tube and re fit or replace it with a new one In case the old inner tube is to be repaired and used again and it happens to get wet during repair then it is easier to re fit it if you powder it lightly with talcum powder Place the rim halves in the tire from the outside Pump up the tire a little Re position the Allen screws in the rim and tighten them firmly Make sure the inner tube does not get pinched between the rims halves Check to make sure that the tire is squarely in place on the rim Pump up the tire to the recommended tire pressure Check to make sure that the tire is still squarely and snugly in place on the rim Screw the valve cap back on Refit the wheel 1529686 R 10 After Use 10 1 Reconditioning The product is suitable for reconditioning Actions to be carried out Cleaning and disinfection Refer to 9 Maintenance page 92 Inspection according to service plan Consult service instructions available from Invacare Adaptation to the user Refer to 5 Adjusting the mobility device to the user s seating posture page 28 10 2 Disposal The equipment wrapping is potentially recyclable The metal parts are used for scrap me
11. Repeat the procedure for the other armrest OS Undo the bolts on both sides of the backrest cover 1 The photograph only shows the bolts on the left hand side 2 Remove the backrest cover 2 3 Replace the backrest cover 2 When doing so ensure that the recesses in the sides are located correctly 10 Retighten the bolts on both sides of the backrest cover 1 again The photograph only shows the bolts on the left hand side On the torque support loosen the locating pin 3 bolt 2 with the Allen key 5 4 4 Adjusting the mobility of the parallel sliding 4 Reduce the load on the armrest by raising it slightly and then armrests remove the locating pin The Pog of the parallel sliding armrest can be adjusted to easier or stiffer 19 Tools ol e 5 mm Allen key 32 1529686 R Adjusting the mobility device to the user s seating posture To make the armrest easier to move release the bolt of the adjusting wrench 1 with the Allen key 2 To make the armrest more difficult to move tighten the bolt of the adjusting wrench 1 with the Allen key 5 4 5 Adjusting the arm support positions for the l e llel slidi Put the armrest in the vertical position Pen ane nny Se 2 Release the interior bolts 1 with the Allen key iY Tools ol e 5mm Allen key 1529686 R 33 Invacare Storm Series 3 Position the armrest horizontally 4 Re tighten the bolts Make sure that the Nordlock washer
12. Seat type eomme nm o o Ground clearance 60 mm Seat height with lifter 400 650 mm Storm 4 440 690 mm Storm 4 X plore Seat Seat height without lifter without lifter 450 480 mm 104 1529686 R Technical data ISO 7176 15 Seat type 112 5 120 man Dimensions in accordance with ISO 7176 15 Seat type Total height e 970 mm e ca 970 mm e 020 mm single part seat frame e 1090 1190 mm telescopic seat frame moving the backrest plate 1529686 R 105 Invacare Storm Series Dimensions in accordance with ISO 7176 15 Seat type Total length incl standard legrests e 1190 mm e ca 1190 mm e 1190 mm Seat height with lifter e 400 650 mm Storm 4 e 440 690 mm Storm 4 X plore Seat height without lifter e 450 480 mm Seat width e 490 530 mm e see manufacturer s data 380 mm 380 430 mm e 430 mm 430 480 mm e 480 mm 480 530 mm e 530 mm 530 580 mm Seat depth e 460 510 mm e 410 510 mm Backrest height e 770 830 mm e 480 540 mm sling back e 560 660 mm telescopic seat frame moving the backrest plate Backrest angle lt 20 393 s gt 90 120 Armrest height e 250 340 290 380 mm Telescopic seat frame e 245 310 mm T armrest e 230 360 mm flip up armrest e 230 300 300 360 mm following armrest Single part seat frame e 275 340 mm Legrest length e 290 460 mm e 290 460 mm 106 1529686 R
13. Storm Series Removing hip support Pull lever upwards 2 Remove hip support from holder Inserting hip support Insert hip support in holder 2 Push lever downwards Ensure that hip support locks with an audible click Adjusting position of hip support 19 Tools il 5mm Allen key 38 Loosen screw Do not remove it 2 Adjust hip support to desired position 3 Tighten screw Adjusting width of hip support I9 Tools 0 i e 2x5 mm Allen key 1529686 R Adjusting the mobility device to the user s seating posture Loosen screws 2 Adjust hip support to desired width i You can adjust the width only smaller than the seat width but not wider 3 Tighten screws Adjusting angle of hip support Tools I9 ol e 5mm Allen key Loosen the two screws A 2 Adjust hip pad to desired depth 3 Tighten screws Adjusting hip pad height You can adjust the hip pad height in two ways e Via its mounting slots e Via its bracket Via mounting slots 19 Tools ul 10mm open ended wrench Loosen screws 2 Adjust hip support to desired angle 3 Tighten screws Adjusting hip pad depth 19 Tools ol e 10mm open ended wrench 1529686 R Invacare Storm Series Loosen the two screws 2 Remove upper screw and friction cap 2 Remove small friction link 3 Remove hip pad bracket f
14. Tire type e 3 00 8 pneumatic puncture protected or e Trelleborg 8x3 00 pneumatic or puncture proof puncture protected Tire pressure The recommended maximum tire pressure in bar or kpa is marked on the side wall of the tire or the rim If more than one value is listed the lower one in the corresponding units applies Tolerance 0 3 bar bar 100 kpa Caster tires Tire type e 3 00 6 pneumatic puncture protected or puncture proof Tire pressure The recommended maximum tire pressure in bar or kpa is marked on the side wall of the tire or the rim If more than one value is listed the lower one in the corresponding units applies Tolerance 0 3 bar bar 100 kpa Driving characteristics Speed 6 km h 10 km h 13 km h Min braking distance 1000 mm 6 km h 2100 mm 10 km h 3400 mm 13 km h Max safe slope without lifter e 11 3 20 according to manufacturer s specifications with 150 kg payload 4 seat angle 20 backrest angle with lifter e 8 15 according to manufacturer s specifications with 150 kg payload 4 seat angle 20 backrest angle 1529686 R 103 Invacare Storm Series Driving characteristics Max climbable obstacle height e 100 mm with curb climber 60 mm without curb climber Turning width e 100 mm Drive range in accordance with ISO e 36 km Storm 4 7176 43 e 42 km Storm 4 X plore 59 km Storm 4 True Track Dimensions in accordance with ISO 7176 15
15. and removing the tray CAUTION A N Injury hazard or material damage if a mobility device which is fitted with a table is transported in a vehicle If a table is fitted always remove it before transporting the mobility device Undo the height adjustment Allen screws 1 2 Set the trunk support to the required height 3 Retighten the screws 5 9 3 Adjusting the depth 5 10 1 19 Tools il 5mm Allen key Loosen wing screw 1 2 Adjust tray towards the left or right 3 Re tighten wing screw 1529686 R 49 Invacare Storm Series 5 10 2 Adjusting the depth of the tray removing the tray Loosen wing screw 2 Adjust tray to desired depth or remove it entirely 3 Re tighten screw 5 10 3 Swinging the tray away to the side The tray can be swivelled up and away to the side to allow the user to get in and out of the mobility device A 50 CAUTION Risk of injury When the tray is raised it does not lock in place in this position Do not tilt the tray up and leave it leaning in this position Never attempt to drive with the tray tilted up Always lower the tray in a controlled manner 5 11 Seat support 5 11 1 Adjusting seat width i Also refer to the following chapter entitled 5 11 2 Adjusting the seat depth page 51 The seat width can be adjusted in stages between 380 and 530 mm 19 Tools ol 4mm Allen key Exploded drawing of seat s
16. backrest for example to reach an object If a posture belt is installed it should be correctly adjusted and used each time you use the mobility device When transferring to a different seat position the mobility device as close as possible to the new seat Safety CAUTION Risk of injury if maximum permissible load is exceeded Do not exceed the maximum permissible load refer to Technical data page 102 The mobility device is only designed for use by a single occupant whose maximum weight does not exceed the maximum permissible load of the device Never use the mobility device to transport more than one person CAUTION Risk of injury due to wrong lifting or dropping of heavy components When maintaining servicing or lifting any part of your mobility device take into account the weight of the individual components especially the batteries Be sure at all times to adopt the correct lifting posture and ask for assistance if necessary CAUTION Risk of injury by moving parts Make sure that no injury is incurred by moving parts of the mobility device like wheels or one of the lifter modules if fitted especially when children are around CAUTION Risk of injury from hot surfaces Do not leave the mobility device in direct sunlight for prolonged periods Metal parts and surfaces such as the seat and armrests can become very hot Invacare Storm Series CAUTION Risk of fire
17. be included in the standard scope of mobility device order and delivery in some countries UK for example but may also be obtained from Invacare as an option in other countries o This mobility device complies with the requirements of ISO 7176 19 and may be used as a vehicle seat in connection with an anchoring system that has been checked and approved in accordance with ISO 10542 The transporting vehicle must be professionally converted to anchor the mobility device Contact your vehicle s manufacturer for more information The mobility device has undergone a crash test in which it was anchored in the transporting vehicle s direction of travel Other configurations were not tested The crash test dummy was secured using pelvic and upper body safety belts Both types of safety belt should be used in order to minimize the risk of injuries to head or upper body It is imperative that the mobility device is inspected by an authorized dealer before being used again after being involved in a crash Alterations to the mobility device anchoring points may not be carried out without the manufacturer s permission 8 3 1 How the mobility device is anchored in a vehicle The mobility device is fitted with four anchoring points which are labelled with the symbol shown on the right Snap hooks or belt loops can be used for fixation 1529686 R Front Rear Secure the mobility device at the front I and at the rear 2 with the anch
18. below Never drive over uneven surfaces when the lifter Identification label sticker on is raised the chassis at the rear right For details see below Read the user manual Warning not to use the cable loop as an anchoring point This symbol indicates the Drive position of the coupling lever In this position the motor is engaged and the motor brakes are operational You can drive the mobility device e Note that for driving purposes both motors must always be engaged Do not drive up or down slopes when the lifter is raised 1529686 R 2l Invacare Storm Series This symbol indicates the Push position of the coupling lever In this position the motor is disengaged and the motor brakes are not operational The mobility device can be pushed by an attendant and the wheels turn freely e Note that the remote must be switched off e Also note the information provided in section 6 9 Pushing the mobility device in freewheel mode page 77 This product complies with Directive 93 42 EEC concerning medical devices The launch date of this product is stated in the CE declaration of conformity This product has been supplied from an environmentally aware manufacturer This product may contain substances that could be harmful to the environment if disposed of in places landfills that are not appropriate according to legislation The crossed out wheelie bin symbol is placed on this product to encourag
19. contact an authorized specialist workshop 2 7 Safety information on wheelchairs with a lifter A WARNING Risk of injury by moving parts Never let objects get caught in the space underneath a raised lifter Make sure that neither you nor anyone else is injured by placing hands feet other body extremities under the raised seat Should you not be able to view under the seat for example due to limited manoeuvrability turn the wheelchair once on its own axel before you lower the seat This will allow you to make sure that nobody is located in the danger zone CAUTION Risk of injury if the wheelchair tips over Never exceed the maximum permissible load see chapter Technical data page 102 Avoid dangerous driving situations when the lifter is in a raised position such as trying to overcome obstacles like kerbs or driving up or down steep gradients Never lean out of the seat when the lifter is raised Inspect the lifter module at least once a month to make sure the automatic speed reduction function which reduces the speed of the wheelchair when the lifter is raised is working properly see chapter 3 3 The Lifter page 23 Notify your authorised dealership immediately if it is not working properly CAUTION Risk of malfunction of the lifter module Inspect the lifter module at regular intervals to make sure there are no foreign objects or visible damage and to make sure the electr
20. dealer Date Signature Stamp of authorized dealer Date Signature 9 4 Short term storage In case a serious fault is detected a number of safety mechanisms are built into your mobility device and will protect it The controller prevents your mobility device from driving When the mobility device is in such a condition and while waiting for repair l 2 Switch off power Disconnect the batteries Depending on the mobility device model you can either remove the battery packs or disconnect the batteries from the power module Refer to the corresponding chapter about disconnecting the batteries Contact your dealer 9 5 Long term storage In case your mobility device is not used for a longer period of time you need to prepare it for storage to ensure a longer life for your mobility device and batteries 1529686 R Storing mobility device and batteries We recommend to store the mobility device at a temperature of 15 C avoid hot and cold extremes when storing to ensure a long service life of the product and batteries The components are tested and approved for greater temperature ranges as detailed below Allowable temperature range to store the mobility device is 40 up to 65 C Allowable temperature range to store batteries is 25 up to 65 C Even not being used batteries discharge themselves Best practice is to disconnect the battery supply from the power module if storing the mobility devic
21. get to your dealer You should immediately stop using your mobility device if its usability is restricted due to e brake failure You should immediately contact an authorized Invacare dealer if the usability of your mobility device is restricted due to e the lighting system if fitted failing or being defective e reflectors falling off e worn thread or insufficient tire pressure e damage to the armrests e g torn armrest padding e damage to the legrest hangers e g missing or torn heel straps e damage to the postural belt e damage to the joystick joystick cannot be moved into the neutral position e cables that are damaged kinked pinched or have come loose from the fixation e the mobility device drifting when braking e the mobility device pulling to one side when moving e unusual sounds developing or occurring Or if you have the feeling that something is wrong with your mobility device 1529686 R 1 8 Warranty The terms and conditions of the warranty are part of the general terms and conditions particular to the individual countries in which this product is sold 1 9 Service life We estimate a service life of five years for this product provided it is used in strict accordance with the intended use as set out in this document and all maintenance and service requirements are met The estimated service life can be exceeded if the product is carefully used and properly maintained and provided technical and s
22. gravel ice etc where there is a risk of you losing control over the vehicle especially on a gradient This may include certain painted or otherwise treated wood surfaces If driving on such a surface is inevitable then always drive slowly and with the utmost caution Never attempt to overcome an obstacle when on an uphill or downhill gradient Never attempt to drive up or down a flight of steps with your mobility device When overcoming obstacles always observe the maximum obstacle height refer to Technical data page 02and information about overcoming obstacles in 6 5 Taking Obstacles page 74 Avoid shifting your center of gravity as well as abrupt joystick movements and changes of direction when the mobility device is in motion Improper positioning while leaning or bending could cause the wheelchair to tip forward resulting in serious injury or damage To assure stability and proper operation of your mobility device you must at all times maintain proper balance Your power wheelchair has been designed to remain upright and stable during normal daily activities as long as you DO NOT move beyond the center of gravity DO NOT lean forward out of the mobility device any further than the length of the armrests DO NOT attempt to reach objects if you have to move forward in the seat or pick them up from the floor by reaching down between your knees 14 1529686 R 1529686 R WARNING Risk
23. motor surfaces when engaging or disengaging CAUTION Risk of the mobility device running away When the motors are disengaged for push operation whilst freewheeling the electromagnetic motor brakes are deactivated When the mobility device is parked the levers for engaging and disengaging the motors must without fail be locked firmly into the DRIVE position electromagnetic motor brakes activated The motors may only be disengaged by an attendant not by the user o This ensures that the motors are only disengaged if an attendant is available to secure the wheelchair and prevent unintended rolling Each motor is fitted with an engaging turn knob which is used to engage or disengage the motor 77 Invacare Storm Series Disengaging the motor Switch off remote 2 Turn the engaging turn knob clockwise The motor is disengaged Engaging the motor s La Turn the engaging turn knob counterclockwise The motor is engaged it Both motors must always be engaged before driving 78 6 9 2 Disengaging the motors True Track Plus motors CAUTION Risk of injury from hot motor surfaces Avoid touching the motor surfaces when engaging or disengaging N CAUTION Risk of the mobility device running away o When the motors are disengaged for push operation whilst freewheeling the electromagnetic motor brakes are deactivated When the mobility device is p
24. or breaking down due to electric devices being connected Do not connect any electric devices to your mobility device that are not expressly certified by Invacare for this purpose Have all electrical installations done by your authorized Invacare dealer 2 2 Safety information on the electrical system A DANGER Risk of death serious injury or damage Misuse of the wheelchair may cause the wheelchair to start smoking sparking or burning Death serious injury or damage may occur due to fire DO NOT use the wheelchair other than its intended purpose If the wheelchair starts smoking sparking or burning discontinue using the wheelchair and seek service IMMEDIATELY DANGER Risk of fire Switched on lamps produce heat If you cover the lamps with fabrics such as clothes there is a risk that the fabric may catch fire NEVER cover the light system with fabric DANGER Risk of death serious injury or damage Corroded electrical components due to water or liquid exposure can result in death serious injury or damage Minimize exposure of electrical components to water and or liquids Electrical components damaged by corrosion MUST be replaced immediately Wheelchairs that are frequently exposed to water liquids may require replacement of electrical components more frequently DANGER Risk of death or serious injury Failure to observe these warnings can cause an electrical short
25. resulting in death serious injury or damage to the electrical system The POSITIVE RED battery cable MUST connect to the POSITIVE battery terminal s post s The NEGATIVE BLACK battery cable MUST connect to the NEGATIVE battery terminal s post s NEVER allow any of your tools and or battery cable s to contact BOTH battery post s at the same time An electrical short may occur and serious injury or damage may occur Install protective caps on positive and negative battery terminals Replace cable s immediately if cable s insulation becomes damaged DO NOT remove fuse or mounting hardware from POSITIVE red battery cable mounting screw 1529686 R DANGER Risk of death or serious injury Electric shock can cause death or serious injury To avoid electric shock inspect plug and cord for cuts and or frayed wires Replace cut cords or frayed wires immediately Risk of damage to the wheelchair A failure in the electric system can lead to unusual behavior such as continuous light no light or noises from the magnetic brakes If a failure exists switch off the remote and switch it on again Ifa failure still exists then disconnect or remove the power source Depending on the mobility device model you can either remove the battery packs or disconnect the batteries from the power module If in doubt which cable to disconnect contact your dealer In any case
26. seat depth in centimeters o o Tools I e 6mm Allen key 1529686 R Adjusting the mobility device to the user s seating posture On both sides loosen the bottom backrest screw Do not remove the screws 2 Move the backrest to the required seat depth You can adjust the seat depth steplessly Use scale on the seat as a guide for this purpose Ensure that the same seat depth is set on both sides 3 Re tighten the screws 5 6 Adjusting the seat angle CAUTION Adjusting the seat tilt or the backrest angle changes the geometry of the mobility device and directly influences its dynamic stability For details regarding dynamic stability negotiating gradients and obstacles and the correct adjustment of seat tilt or backrest angle refer to 6 5 Taking Obstacles page 74 and Driving up and down gradients 5 6 1 Electrical Consult the user manual for your remote for information about electrical adjustment 4 Invacare Storm Series 5 6 2 Manual The seat angle is adjusted using an adjusting mechanism which consists of 2 perforated strips which can be pushed against each other The adjusting mechanism is at the front under the seat frame When adjusting the seat angle ensure that both fixing screws are always used to fix the adjusting mechanism i Activate the motor brakes engage motor before adjusting the seat angle Only adjust the seat angle manually if nobody is sitting in the seat
27. shorter is its life expectancy Examples One deep discharge stresses the same as 6 normal cycles green orange display off The battery life is about 300 cycles at 80 discharge first 7 LED off or about 3000 cycles at 10 discharge one LED off i The number of LED can vary depending on the remote type e Under normal operation once a month the battery should be discharged until all green and orange LED are off This should be done within one day A 16 hour charge afterwards is necessary as reconditioning 7 2 7 Transporting batteries The batteries supplied with your mobility device are not hazardous goods This classification is based on the German GGVS Hazardous Goods Road Transport Ordinances and the IATA DGR Hazardous 1529686 R Goods Rail Transport Air Transport Ordinances Batteries may be transported without restrictions whether by road rail or by air Individual transport companies have however guidelines which can possibly restrict or forbid certain transport procedures Please ask the transport company regarding each individual case 7 2 8 General instructions on handling the batteries Never mix and match different battery manufactures or technologies or use batteries that do not have similar date codes Never mix gel with AGM batteries The batteries reach their end of life when the drive range is significantly smaller than usual Contact your dealer or service technician for details Alw
28. the calf width of the user 5 15 4 Adjusting the angle of the foot plate S16 Vari F footrest errei oso eee eee eer eee eee 5 16 1 Swivelling the footrest legrest outward and or PEIIOV ING sce sini dings Eeee ane Aaa a a e aod eta Setting the angle 2 eee ee ee es 5 16 3 Setting the end stop of the footrest 5 16 4 Adjusting the length of the footrest 5417 VarkAdegrestSr erus ere Pee ear eee ee wee hae 4 5 16 2 5 17 1 Swivelling the footrest legrest outward and or PEIMIGVING srh eea ao eto et bee Aare ee Bed EA 62 S 17 2 Setting the angle 2 lt aered ir esos eGR Shoes ak 63 5 17 3 Setting the end stop of the legrest 64 5 17 4 Adjusting the length of the legrest 66 5 17 5 Adjusting the depth of the calf pad 66 5 17 6 Adjusting the height of the calf pad 67 5 17 7 Unlocking and swivelling the calf pad backward whenalighting i 2 cereris ee ntie aces eee 67 5 17 8 Adjusting the angle adjustable foot plate 68 5 17 9 Adjusting the angle and depth adjustable foot PCS scat a aes ss Ge ae whe ER eee ects enced Wa 68 5 18 Powered elevating legrests ADE legrests 69 5 18 1 Swivelling the legrest outward and or removing 69 518 2 Setting the angle wns ooo gash wee eee ee a 69 5 18 3 Adjusting the length of the legrest 69 5 18 4 Adjusting the depth of the calf pad 70 5 18
29. 1529686 R Safety More than 30 NEVER 5 30 Standstill 0 15 Driving Invacare Storm Series 2 9 The position of the labels on the product 20 ISO 7176 19 If the mobility device is fitted with a tray it is imperative that it is removed and safely stowed when transporting the mobility device in a vehicle This symbol indicates the position of an anchoring point when using an anchoring system during transport If the symbol appears on a bright yellow sticker the anchoring point is suitable for fixation of the mobility device in a vehicle for use as a vehicle seat Warning that the mobility device may not be used as a vehicle seat This mobility device does not satisfy the requirements of ISO 7176 19 This mobility device may be used as a vehicle seat but only if it is equipped with a headrest that has been approved by Invacare for this purpose e Always make sure that the mobility device is equipped with a headrest approved by Invacare before using it as a vehicle seat Warning regarding the use of the lifter For details see below 1529686 R Safety Indication of the maximum Do not allow any body parts to get under a raised width to which the armrest seat can be set Identification of the position of the coupling lever for Never drive with two people driving and push operation only the right side is visible in the picture For details see
30. 380 and 530 mm only be carried out by trained specialists Contact your authorized Invacare specialist dealer Tools ji It is easier to adjust the suspension and shock absorbance if 4mm Allen key there is no one sitting in the chair 5 13 1 Adjusting the suspension Storm4 X plore only Remove the backrest cushion Loosen the three Allen screws 1 Do not however remove Softer Harder these screws completely Push the plate 2 as far as required until the required width in cm can be read off the scale 3 Tighten the three Allen screws again Adjusting the suspension harder Repeat these operations on the other backrest plate l i Rotate the adjustable spring plate 1 as shown in the illustration Attach a backrest cushion of the required width in order to adjust the suspension harder 1529686 R Adjusting the mobility device to the user s seating posture Adjusting the suspension softer 5 13 3 Adjusting the shock absorbance In the case of the Storm X plore the shock absorbance can be Rotate the adjustable spring plate 1 as shown in the illustration quickly and simply adjusted using a wheel on the springs in order to adjust the suspension softer e If you set the shock absorbance harder you get a more direct response to the ground for more sportive driving with a less swinging chassis The softer you set the shock absorbance the softer the response l to the ground is and the more comfortable the dr
31. 529686 R Notes Invacare Sales Companies Australia Invacare Australia PTY Ltd Lenton Place North Rocks NSW 2151 Australia Phone 1800 460 460 Fax 1800 814 367 orders invacare com au www invacare com au United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776 222 Fax 44 0 1656 776 220 uk invacare com www invacare co uk 1529686 R 2015 10 01 Canada Invacare Canada LP 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada Phone 905 890 8300 Fax 905 501 4336 Eastern Europe amp Middle East Invacare GmbH EDO KleiststraBe 49 D 32457 Porta Westfalica Tel 49 0 57 31 754 540 Fax 49 0 57 31 754 541 edo invacare com www invacare eu com Ireland Invacare Ireland Ltd Unit 5 Seatown Business Campus Seatown Road Swords County Dublin Tel 353 810 7084 Fax 353 810 7085 ireland invacare com www invacare ie Making Life s Experiences Possible New Zealand Invacare New Zealand Ltd 4 Westfield Place Mt Wellington 1060 New Zealand Phone 0800 468 222 Fax 0800 807 788 sales invacare co nz www invacare co nz Manufacturer Invacare Deutschland GmbH KleiststraBe 49 32457 Porta Westfalica Yes you can
32. Invacare Storm Series N fa g U C qf lt 9 gt pa H vt pa O Pas Y o pa Ke xX vr pa O Pas Y lt z pan O Pas Y i R a os U Q O Co Se Cc ee a og a D C YM Yes you can BEFORE using this product read this manual and save for future reference This manual MUST be given to the user of the product CE 2015 Invacare Corporation All rights reserved Republication duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Contents I GOnGPal ico 60 2c SO 6G see eene otek eu eee ees 7 Mel troduction sienien ahead jo de stp ta taille is ant te cabanas a 7 1 2 Symbols in this manual 2 00 0 eee eee 7 3 Type Classification carat dears acento dine ace Goat eae ate nck Res 7 14 Intended Use s 242c05e25 26 4484 dnra boive cde ae Ce 8 lor UREQUIACIONS 45 049 a aaen eke See ble eo ee bag 8 Y 26 5 dications iere he ese gn ct ales Aidt lw de Decree 8 fel SaB 2 6 e c ace tn are ead eet r Bale ae er tls 8 Eo CVV arbanty 225 ton ato oh ean E E E E nitan eas E ate es 9 l7 Service INE ciara tie SA Sate ee Baise kee wake oaks eles 9 L Salty eas se oe E ewes Sa vee tes ewa estes ees 10 2 1 General safety notes 0 ee e
33. OJ 35 Invacare Storm Series 5 5 5 Adjusting the height following armrest iY Tools ol e 5mm Allen key e 13 mm open ended spanner fT Loosen the screw and nut and remove them 2 Adjust armrest to desired height 3 Insert screw and nut and tighten 5 5 6 Changing the resistance flip up following armrest The movement of the flip up and following armrests can be set to have greater or less resistance 36 19 Tools i e 5 mm Allen key Lace To make the armrest easier to move release the screw A with the Allen key 2 To make the armrest more difficult to move tighten the screw with the Allen key 5 5 7 Adjusting the arm pad angle flip up following armrest 19 Tools ol e 5 mm Allen key 1529686 R Adjusting the mobility device to the user s seating posture Loosen screws oO lI Do not remove them 2 Adjust arm pad to desired angle 3 Tighten screws 5 5 8 Adjusting the position of the arm pad of the flip up armrest Y Tools ol 5mm Allen key Position the armrest horizontally 4 Re tighten the bolts Make sure that the Nordlock washers used are re inserted 5 5 9 The hip support The hip support can be combined with the flip up armrest only Put the armrest in the vertical position 2 Release the interior bolts I with the Allen key 1529686 R 37 Invacare
34. Refit the wheel 9 7 2 Repairing punctures drive wheel with True Track Plus motor and pneumatic tires A CAUTION Risk of injury If the wheel has been insufficiently tightened during assembly it can become loosened during driving When reassembling the drive wheels tighten the Allen screws at a torque of 25 Nm Secure all screws using a suitable blocker e g Loctite 243 Tools 6 mm open ended spanner Torque wrench Repair kit for tire repair or a new inner tube Talcum powder Screw blocker Loctite e g Loctite 243 1529686 R Removing the wheel Block up the vehicle place wooden blocks under frame Unscrew valve cap Depressurize tire by pressing in the pin in the valve 1 Unscrew 5 screws 2 Remove the wheel rim halves Remove the inner tube from the tire Dau BRWN i Re assembly is done in reverse order Ensure that the tire is replaced on the same side and in the same travel direction as it was previously mounted Repair the flat tire Repair inner tube and replace or insert new il If the old inner tube is to be repaired and re used and has become wet during repair you can make replacement easier by sprinkling the inner tube with a little talcum powder 2 Replace the inner tube in the tire 3 Insert the wheel rim halves once again 4 Insert the screws and tighten slightly 5 Pump alittle air into the inner tube 1529686 R Maintenance 6 Tighten the screws t
35. Removing the wheel Block up the vehicle place wooden blocks under frame Unscrew the screw 1 Remove the wheel from the hub _ 97 Invacare Storm Series i Re assembly is done in reverse order Ensure that the tire is replaced on the same side and in the same travel direction as it was previously mounted Repairing the flat tire Dau BRWN 7 8 98 A CAUTION Risk of explosion The wheel will explode if you do not let the air out of the tire before removing the wheel Always let the air out of the tire before removing it press in the pin in the middle of the valve Unscrew valve cap Depressurise tire completely by pressing in the pin in the valve Remove the 5 cylinder head screws back of the wheel 2 Remove the rim halves from the tire Remove the inner tube from the tire Repair inner tube and replace or insert new o If the old inner tube is to be repaired and re used and has Il become wet during repair you can make replacement easier by sprinkling the inner tube with a little talcum powder Insert the wheel rim halves from outside into the tire Pump a little air into the inner tube 9 Reinsert the cylinder head screws and tighten tol0 Nm Avoid crushing the inner tube 10 Ensure that the tire outer is seated correctly Pump the tire up to the prescribed pressure 12 Ensure that the tire outer is seated correctly again 13 Screw the valve cap back on 14
36. Technical data page 102 Put your backrest into an upright position before ascending an obstacle 1529686 R CAUTION Risk of falling out of the mobility device and damage to the mobility device such as broken casters Never approach obstacles that are higher than the maximum climbable obstacle height For the maximum climbable obstacle height refer to Technical data page 102 Never let the footrest legrest touch the ground when descending an obstacle If unsure whether taking an obstacle is possible or not move away from the obstacle and if possible find another location 6 5 3 The correct way to overcome obstacles ed Right Ascending Approach the obstacle or the curb slowly head on and at a right angle 2 Depending on the wheel drive type stop in one of the following positions a In the case of centrally driven mobility devices 5 10 cm before the obstacle b For all other drives approx 30 50 cm in front of the obstacle 1529686 R Usage 3 Check the position of the front wheels They must be in driving direction and at right angles to the obstacle 4 Approach slowly and keep at a consistent speed until the rear wheels have also passed over the obstacle Descending The approach to descend an obstacle is the same as to ascend it with the difference that you need not to stop before descending Descend the obstacle with medium speed o When descending an obstacle too slo
37. act your mode for all lights such as dealer indicators headlights and rear lights Batteries Check of battery charging Charge the status Please refer to the batteries see remote manual for information chapter 7 2 3 about battery charging status How to charge display the batteries page 81 Foldable Check whether the antitippers Bring the antitippers are in the driving position antitippers into the driving position see chapter 6 7 Using foldable antitippers page 76 Check whether the locking pin is fully engaged Make sure that the locking pin engages 1529686 R 9 3 2 Weekly If inspection is not Item Inspection check passed Armrests side parts Check that armrests Tighten the screw or are firmly attached clamping lever that holds in their holders and the armrest see chapter do not wobble 5 Adjusting the mobility device to the user s seating posture page 28 Contact your dealer Tires Check that the tires Contact your dealer pneumatic are undamaged Check that the tires Inflate the tire to the are inflated to the correct pressure see correct pressure chapter Technical data page 102 Repair the inner tube if you have a flat tire see chapter 9 7 Repair Instructions page 97 or contact your dealer to have it repaired Tires Check that the tires Contact your dealer puncture are undamaged proof 9 3 4 Inspections performed Maintenance 9 3 3 Month
38. ara Sa eee sag es Be 78 T Electrical Systems 4 0 6 6 6 9 526 06 eS eseese teena SN 80 7 1 Electronics protection system 2 02 eee 80 72 BAtterieS s 24 trio ade iy Mele ale Baek Aad oe RE 2 80 7 2 1 General information on charging 80 7 2 2 General instructions on charging 80 7 2 3 How to charge the batteries 8l 7 2 4 How to disconnect the mobility device after anaia a EA E E E ne See utes E 8 7 2 5 Storage and Maintenance 00000 8l 7 2 6 Instructions on using the batteries 82 7 2 7 Transporting batteries 2 0 0c eee eee 82 7 2 8 General instructions on handling the batteries 83 7 2 9 How to handle damaged batteries correctly 83 6 Trans DOF ii ai 46a a s trace hte hea slave eth ah eas eg OS 84 8 1 Transport General information 84 8 2 Transferring the mobility device to a vehicle 84 8 3 Use of the mobility device as a seat ina vehicle 85 8 3 1 How the mobility device is anchored in a vehicle 86 8 3 2 How the user is secured within the wheelchair 87 8 4 Transporting the mobility device without occupant 88 8 4 1 Opening the rear cover 0 02 e eee 89 8 4 2 Making the batteries accessible 89 8 4 3 Removing Installing the batteries 90 9 MainCenance 4 694 546 3653 er erR EEI OEE oes EEA 92 9 1 Maintenance intr
39. ari A legrests 5 17 1 Swivelling the footrest legrest outward and or removing The small unlocking button is located on the upper section of the footrest legrest When the footrest legrest is unlocked it can be 1529686 R Adjusting the mobility device to the user s seating posture swivelled inward or outward when getting into the wheelchair as l well as being removed completely Loosen the locking knob I counter clockwise at least one turn Press the unlocking button I and swivel the footrest legrest outward 2 Remove the footrest legrest in an upward direction 5 17 2 Setting the angle CAUTION Risk of injury due to incorrect adjustment of the footrests and legrests Before and during every journey it is imperative to ensure that the legrests contact neither the caster wheels nor the ground Hit the knob to release the locking mechanism 1529686 R 63 Invacare Storm Series 3 l The end position of the legrest is determined by means of a rubber stop I Set the desired angle 2 4 The rubber stop can be screwed in or out or pushed up or Turn the knob clockwise to tighten it down 5 17 3 Setting the end stop of the legrest 19 Tools ol e 10mm open ended spanner 64 1529686 R Adjusting the mobility device to the user s seating posture A Loosen the locking knob I counter clockwise at least one turn l i f 4 Swivel the legrest upward in order to access th
40. arked the levers for engaging and disengaging the motors must without fail be locked firmly into the DRIVE position electromagnetic motor brakes activated The motors may only be disengaged by an attendant not by the user This ensures that the motors are only disengaged if an attendant is available to secure the mobility device and prevent unintended rolling Each motor is fitted with an engaging lever which is used to engage or disengage the motor 1529686 R Disengaging the motor Switch off remote 2 Pull the locking pin out and push the engaging lever forwards The motor is now disengaged 1529686 R Usage Engaging the motor l Pull the engaging lever to the rear The motor is now engaged ji Note that both motors must always be engaged before driving 79 Invacare Storm Series 7 Electrical system 7 1 Electronics protection system The vehicle drive electronics is fitted with an overload protection If the drive is severely overloaded over a long period for example during steep climbs and above all at simultaneous high external temperatures the electronic system can overheat In this case the vehicle performance is gradually reduced until it comes to a standstill The status display shows a corresponding flash code please refer to the user manual for your remote If you switch the drive electronics off and then on again the error message is deleted a
41. ays have your batteries installed by a properly trained mobility device technician or a person with adequate knowledge They have the necessary training and tools to do the job safely and correctly 7 2 9 How to handle damaged batteries correctly CAUTION Corrosion and burns from acid leakage if batteries are damaged Remove clothes that have been soiled by acid immediately After contact with skin Immediately wash affected area with lots of water After contact with eyes Immediately rinse eyes under running water for several minutes consult a physician 1529686 R Electrical system e Always wear safety goggles and appropriate safety clothing when handling damaged batteries e Place damaged batteries in an acid resistant receptacle immediately after removing them e Only ever transport damaged batteries in an appropriate acid resistant receptacle e Wash all objects that have come into contact with acid with lots of water Disposing of dead or damaged batteries correctly Dead or damaged batteries can be given back to your dealer or directly to Invacare 83 Invacare Storm Series 8 Transport 8 1 Transport General information CAUTION Injury hazard or material damage if a mobility device which is fitted with a table is transported in a vehicle If a table is fitted always remove it before transporting the mobility device 84 8 2 Transferring the mobility device t
42. cientific advances do not result in technical limitations The service life can also be considerably reduced by extreme or incorrect usage The fact that we estimate a service life for this product does not constitute an additional warranty 1529686 R General Invacare Storm Series 2 Safety 2 1 General safety notes A A WARNING Risk of injury if mobility device is used in any other way than the purpose described in this manual Only ever use the mobility device in accordance with the instructions in this user manual Pay strict attention to the safety information WARNING Risk of injury if the mobility device is driven when ability to operate a vehicle is impaired by medication or alcohol Never drive the mobility device under the influence of medication or alcohol If necessary the mobility device must be operated by an attendant who is physically and mentally able WARNING Risk of damage or injury if mobility device is accidentally set into motion Switch the mobility device off before you get in get out or handle unwieldy objects When the drive is disengaged the brake inside the drive is deactivated For this reason pushing the mobility device by an attendant is only recommended on flat surfaces never on gradients Never leave your mobility device on a gradient with its motors disengaged Always re engage the motors immediately after pushing the mobility device refer to Pu
43. contact your dealer 2 3 Safety information on electromagnetic interference This electric vehicle was successfully tested in accordance with International standards as to its compliance with Electromagnetic Interference EMI regulations However electromagnetic fields such as those generated by radio and television transmitters and cellular phones can influence the functions of electric vehicles Also the electronics used in our vehicles can generate a low level of electromagnetic interference which however will remain within the tolerance permitted by law For these reasons we ask you to please observe the following precautions 1529686 R Safety WARNING Risk of malfunction due to electromagnetic interference Do not switch on or operate portable transceivers or communication devices such as radio transceivers or cellular phones when the vehicle is switched on Avoid getting near strong radio and television transmitters In case the vehicle should be set in motion unintentionally or the brakes are released switch it off immediately Adding electrical accessories and other components or modifying the vehicle in any way can make it susceptible to electromagnetic interference Keep in mind that there is no sure way to determine the effect such modifications will have on the overall immunity of the electronic system Report all occurrences of unintentional movement of the vehicle or release of the elec
44. d using the postural belt whenever the Il mobility device is used The belt should be tight enough to ensure that you are sitting comfortably and that your body is in the correct sitting position 4 1 1 Types of postural belts Your mobility device can be fitted with the following postural belt types ex works If your mobility device has been fitted with a different belt to those listed below please ensure that you have received the manufacturer s documentation with regard to correct fitting and use Belt with metal buckle adjustable one side Belt can only be adjusted on one side which can result in the buckle not sitting centrally 1529686 R Accessories Belt with metal buckle adjustable both sides Belt can be adjusted on both sides This means that the buckle can be centrally positioned 4 1 2 Adjusting the postural belt correctly Ensure that you are sitting correctly which means that you are sitting right at the back of the seat your pelvis is positioned erect and as symmetrically as possible not to the front to the side or at one edge of the seat 2 Position the postural belt so that your hipbones can be easily felt above the belt 3 Adjust the belt length using one of the adjustment aids described above The belt should be adjusted so that you can fit a flat hand between the belt and your body 4 The buckle should be positioned as centrally as possible In doing SO Carry Out adjustments on both sides a
45. d wheel 1 5 7 5 Adjusting the width of the backrest Modulite 5 7 4 Adjusting the height of the backrest Modulite seat unit You can adjust the backrest plate width to a certain degree by ni ca l seat unit adjusting the front plate e g in order to adjust the backrest plate in The following section describes the procedures for adjusting the line with the seat cushion Fairly large adjustments must be made by height of the backrest plate a service technician to the rear plate and are outlined in the service The sling back is only available in fixed heights of 48 and 54 cm o0 19 Tools il e 5mm Allen key 1529686 R instructions for this mobility device 43 Invacare Storm Series o The sling back is only available in two widths of 38 43 cm and I 48 53 cm and under certain circumstances must be replaced for a width adjustment For a replacement description see the service instructions for this mobility device The service instructions can be ordered from Invacare However they contain instructions for specially trained service technicians and describe operations that are not intended for the end user Note that if the sling back width is adjusted the backrest cushion must also be replaced Tools S oC e 5mm Allen key Loosen and remove the backrest plate screw 2 Loosen the backrest plate screws Do not remove the screws 3 Move the backrest plate halves to the required width
46. djust the seat depth as described in the following chapter necessary to replace the seat support plate If the seat support plate does not need to be replaced please refer to chapter 5 11 3 Adjusting the seat depth without replacing Please use the following figures and the table to determine which the seat support plate page 52 holes need to be used for the required seat depth and therefore If the seat support plate does need to be replaced please refer whether the seat support plate needs to be replaced or not 1529686 R 5I Invacare Storm Series to chapter 5 11 4 Adjusting the seat depth with replacing the seat 5 Repeat these operations on the other side of the seat support plate page 53 6 Undo and remove the two Allen screws 5 including washers 5 11 3 Adjusting the seat depth without replacing Assembly the seat apon plate Pull the seat support to the required length so that the Allen screws 5 can be inserted in the holes in accordance with the aoe iy table see above Ly 2 Insert the Allen screws 5 including washers again and tighten them 9 E 3 Fit the two Allen screws 8 which are located at the rear of the ee ee os seat support and connect them with the crossmembers 4 You yy S4 Ge gt must be using other holes within the 3 hole pairs for the screws On os ga an gt than you did during dismantling i gt d A 4 Refit all the parts you have removed Exploded drawing of seat supp
47. e a year by an authorised Invacare dealer in order to maintain its driving safety and roadworthiness 9 2 Cleaning the mobility device When cleaning the mobility device pay attention to the following points e Only use a damp cloth and gentle detergent e Do not use any abrasive or scouring agents e Do not subject the electronic components to any direct contact with water e Do not use any high pressure cleaning devices Disinfection Spray or wipe disinfection using a tested and recognised product is permitted A list of the current permitted disinfectants is available from the Robert Koch Institute at http www rki de 9 3 Inspection checks The following table lists inspection checks that should be performed by the user and their intervals If the mobility device fails to pass one of the inspection checks refer to the chapter indicated or contact your authorised Invacare dealer A more comprehensive list of inspection checks and instructions for maintenance work can be found in the service manual for this device which can be obtained 92 from Invacare That manual however is intended to be used by trained and authorized service technicians and describes tasks which are not intended to be performed by the user 9 3 1 Before each use of the mobility device If inspection Item Inspection check is not passed Horn Check of correct mode of Contact your operation dealer Lighting unit Check of correct operating Cont
48. e and longevity Thus range and running time of your mobility device could initially increase with use Gel AGM lead acid batteries do not have a memory effect as NiCd batteries 7 2 2 General instructions on charging Follow the instructions listed below to ensure safe use and longevity of the batteries e Charge 18 hours prior to initial usage e We recommend charging the batteries daily after every discharge even after partly discharge as well as each night over night Depending on the level of discharge it can take up to 12 hours until the batteries are fully charged again e When the battery indicator reached the red LED range charge the batteries for 16 hours minimum neglecting the charge complete display e Try to provide a 24 hour charge once a week to make sure that both batteries are fully charged e Do not cycle your batteries at a low state of charge without regularly recharging them fully e Do not charge your batteries under extreme temperatures High temperatures above 30 C are not recommended for charging as well as low temperatures below 10 C 1529686 R e Use only charging devices in Class 2 This class of chargers may be left unattended during charging All charging devices which are supplied by Invacare comply with these requirements e You cannot overcharge the batteries when using the charger supplied with your mobility device or a charger that has been approved by Invacare e Protect your charger f
49. e arm pad angle flip up following BUG CSC iso 8 re ate Bale eee E E E E E E eee Adjusting the position of the arm pad of the flip up ALITA CSC toe cose hs oo a a NA S92 The hip SUPPO C 4 5 ose ost sexe te ee tno Pe ee AA 5 5 10 Adjusting the seat width 000 5 5 11 Adjusting the seat depth 2000 5 6 Adjusting the seatangle 2 0 e eee eee DO EECC saa fake dpa oa ee ae a ON Pee ee ede 562 Manual opadan Son 4 Sse as Se eA eee oA oA 5 7 Adjusting the backrest 0 0 2c ee eee ee eee BoP Electrical ne Site ow hay p tata aan ek Yo Sone ae 5 7 2 Adjusting the backrest standard seat manually with handscrews 2 e eee ee eee eee Adjusting the back seat angle on the Easy Adapt seating SYSTEM ca Steers aod Be ee Adjusting the height of the backrest Modulite seat 5 5 8 5 7 3 5 7 4 5 7 5 5 7 6 Adjusting the backrest angle Modulite seat unit 5 7 7 Adjusting the adaptable backrest padding 5 8 Adjusting the headrest 0 000 eee eee eee 5 8 1 Adjusting the position of the headrest or neckrest 5 8 2 Adjusting the height of the headrest or neckrest 5 8 3 Adjusting the cheek supports 0 5 9 Adjusting the trunk supports 000 eee ee 5 9 1 Adjusting the width 0 eee 5 9 2 Adjusting the height 20 0 eee eee 5 9 3 Adjusting the depth 0202s 5 10 Adjusting and removin
50. e caution WARNING Risk of injury If your mobility device has been fitted with elevating legrests there is a risk of personal injury and damage to the mobility device if you drive the mobility device with the legrests raised To avoid unwanted displacement of the mobility device center of gravity to the front especially when travelling downhill and in order to avoid damage to the mobility device elevating legrests must always be lowered during normal travelling WARNING Risk of tipping Antitippers stabilizers are only effective on firm ground They sink in on soft ground such as grass snow or mud if the mobility device rests itself on them They lose their effect and the mobility device can tip over Only drive with extreme care on soft ground especially during uphill and downhill journeys In the process pay increased attention to the tip stability of the mobility device Invacare Storm Series A WARNING Risk of injury or damage Operating the wheelchairs outdoors or in areas of poor lighting may cause injury or damage Operating the wheelchair near motor vehicles may cause injury or damage DO NOT operate on roads streets or highways Use caution when operating the wheelchair outdoors at night or in areas with poor lighting ALWAYS be aware of motor vehicles when using the wheelchair 2 5 Safety information with regard to care and maintenance A DANGER Risk of deat
51. e ee eee 10 2 2 Safety information on the electrical system 12 2 3 Safety information on electromagnetic interference 3 2 4 Safety information on driving and freewheel mode 3 2 5 Safety information with regard to care and mantenan es ererrs p eera dh a ea A aR l6 2 6 Safety information regarding changes and modifications to the mobility device 2 02 eee l6 2 7 Safety information on wheelchairs with a lifter 18 2 8 Safety information on wheelchairs with Recaro seats and AJ Optimist SEats 4 oo yd rarae ee a ewe oe 19 2 9 The position of the labels on the product 20 3 COMPONENES 64 57 525ni eos reaa a aa 23 3 1 Main parts of the wheelchair 02000 23 32 HREMOLES cena ee na eee T aa O a 23 33 THE LME erasidan Ae ee a a e e a 23 A PCCESSONIGS essiri eaa a E AR 25 Al Postural Dels curs a4 Ne daia E Ee A 25 4 1 1 Types of postural belts 02 06 25 4 1 2 Adjusting the postural belt correctly 25 4 2 Using the cane holder 0 020s 25 4 3 Using the KLICKfix adapter 0 26 4 4 Adjusting or removing the luggage carrier 26 5 Adjusting the mobility device to the user s seating POSURE iis si sss keine eG ee ees ees ee 28 5 1 General information on adjusting the wheelchair to the user s seating posture 0 cece eee eee eee 28 5 2 Adjustment possibility for remote
52. e longer than two weeks Depending on the mobility device model you can either remove the battery packs or disconnect the batteries from the power module Refer to the corresponding chapter about disconnecting the batteries If in doubt which cable to disconnect contact your dealer Batteries should always be fully charged before storing 95 Invacare Storm Series Preparing mobility device for use 96 If storing the mobility device longer than four weeks check the 9 6 Disconnect the power module batteries once a month and recharge as needed before gauge reads half full to avoid damage Store in a dry well ventilated environment protected from outer influences Slightly overinflate pneumatic tires Position the mobility device on flooring that is not discolored by contact with tire rubber Re connect the battery supply to the power module The batteries must be charged before use Have the mobility device checked by an authorized Invacare Remove the rear cover refer to 8 4 1 Opening the rear cover dealer page 89 Remove the battery cable I from the power module 1529686 R 9 7 Repair Instructions O I Important information about maintenance work tools Some maintenance work which is described in this manual and can be carried out by the user without problems require the correct tools for proper work If you do not have the correct tool available we do not recommend that you try to carry o
53. e rubber stop E Use the open ended spanner to loosen the counternut 1 Hit the knob to release the locking mechanism 1529686 R 65 Invacare Storm Series 7 5 17 4 Adjusting the length of the legrest CAUTION A Risk of injury due to incorrect adjustment of the footrests and legrests Before and during every journey it is imperative to ensure that the legrests contact neither the caster wheels nor the ground Tools 9 il Allen k Move the rubber stop to the desired position 5 mm Allen key 8 Re tighten the counternut 9 Use the spanner to loosen the screw 1 2 Adjust to the desired length 3 Re tighten the screw 5 17 5 Adjusting the depth of the calf pad The depth of the calf pad can be adjusted via the holding plate The holding plate hole combinations allow 5 different depth settings Move the legrest to the desired position 10 Re tighten the locking knob 66 1529686 R Adjusting the mobility device to the user s seating posture 19 Tools al e 10mm open ended spanner Use the Allen key to loosen the screws 1 2 Adjust to the desired position 3 Re tighten the screws 5 17 7 Unlocking and swivelling the calf pad backward when alighting Use the open ended spanner to loosen the nut 1 and remove 2 Adjust to the desired depth Please observe that the round holes are intended for the calf pad retaining screw and the oblong holes for the aglet withou
54. e the batteries when the Battery Charge Indicator shows that battery charge is low How fast the batteries discharge depends on many circumstances such as ambient temperature condition of the surface of the road tire pressure weight of the driver way of driving and utilisation of lighting if fitted Try to charge the batteries always before you reach the red LED range The last 3 LED two red and one orange mean a remaining capacity of about 5 Driving with flashing red LED s means an extreme stress for the battery and should be avoided under normal circumstances e When only one red LED is flashing the Battery Safe feature is enabled From this time speed and acceleration is reduced drastically It will allow you to move the mobility device slowly out of a dangerous situation before the electronic finally cuts off This is deep discharging and should be avoided e Be aware that for temperatures below 20 C the nominal battery capacity starts to decline For example at 10 C the capacity is reduced to about 50 of the nominal battery Capacity e To avoid damaging the batteries never allow them to be fully discharged Do not drive on heavily discharged batteries if it is not absolutely necessary as this will strain the batteries unduly and shorten their life expectancy e The earlier you recharge the batteries the longer they live e The depth of discharge affects the cycle life The harder a battery has to work the
55. e you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life 22 1529686 R 3 Components 3 1 Main parts of the wheelchair Headrest Backrest Armrest Battery case rear Drive wheel Drive motor with engaging lever Remote Legrests o GO NWO UT FR WD NY Caster wheel 1529686 R Components I0 Suspension rear both not visible in illustration adjustable for Storm4 X plore only Suspension center Storm4 X plore only 3 2 Remotes Your mobility device may be fitted with one of several different remotes For information on the different functions and how to operate a particular remote refer to its corresponding user manual enclosed 3 3 The Lifter The electric lifter is operated from the remote Refer to the remote manual for more information 5 Information regarding operation of the lifter at I temperatures of less than 0 C Invacare mobility aids are fitted with safety mechanisms that prevent capacity overload of the electronic components At operating temperatures below freezing point this can in particular lead to the lifter actuator being shut down after approx second operating time The lifter can be raised or lowered gradually by repeatedly operating the joystick In many cases this generates sufficient heat for the actuator to operate as normal 23 Invacare Storm Series
56. es The maximum permissible angle is between 30 and 75 The angle should never be less than 30 Seat belts may not be held at a distance from the user s body using parts of the wheelchair such as armrests or wheels The safety belt installed in the transporting vehicle should be applied as shown in the illustration above Center line of the body 2 Center of the sternum 8 4 Transporting the mobility device without occupant 7 CAUTION Sep Risk of injury If you are unable to fasten your mobility device securely in a transport vehicle Invacare recommends The pelvic belt should be positioned in the area between the user s that you do not transport it pelvis and thighs so that it is unobstructed and not too loose The ideal angle of the pelvic belt to the horizontal is between 45 and 75 88 1529686 R Your mobility device may be transported without restrictions whether by road rail or by air Individual transport companies have however guidelines which can possibly restrict or forbid certain transport procedures Please ask the transport company regarding each individual case e Before transporting your mobility device make sure the motors are engaged and that the remote is switched off Invacare strongly recommends that you additionally disconnect or remove the batteries Refer to Removing the batteries e Invacare strongly recommends securing the mobility device to the floor of the transportin
57. g the tray 36 36 37 37 4 4 4 4 42 42 42 42 43 5 10 1 Laterally adjusting the tray 2 5 10 2 Adjusting the depth of the tray removing the CRAY 5 Sse a 2 eee 6 oir ee gle Bie Bay ee ere tees pene 5 10 3 Swinging the tray away to the side Dall Seat SUPPO meier ae aro es Se tet mele ache 5 11 1 Adjusting seat width 2 0 cee eee eee 5 11 2 Adjusting the seat depth 00 5 11 3 Adjusting the seat depth without replacing the seat SUPPOMt Plates i oot eee Mee ee eee hs 5 11 4 Adjusting the seat depth with replacing the seat SUPpOrt Plate rruen bce e eee 2t68 ido Bad Ya Se 5 12 Backrest unit with ergonomic length compensation EASY Adapt ace hotest eta Ne ae yk ae Sate alana 5 12 1 Adjusting the width 2 02 00 5 13 Adjusting the suspension and the shock absorbance 5 13 1 Adjusting the suspension Storm X plore only 5 13 2 Disabling the suspension and shock absorbance 5 13 3 Adjusting the shock absorbance 5 14 Center mounted legrests Electric legrest 5 14 1 Lowering the electric legrest completely to assist getting out of the wheelchair 4 5 15 Center mounted legrests Adjustable legrest 5 15 1 Adjusting the angle 0 eee ee eee 5 15 2 Adjusting the length of the legrest 5 15 3 Adjusting the calf pad to
58. g vehicle 8 4 1 Opening the rear cover p i z Ean ro y A d i a z at r z Removing the rear cover Loosen and remove the two knobs 1 on the left and right side of the rear casing 2 Lift the rear cover carefully The front part of the cover is held at the top by a Velcro strip This must also be released Fitting the rear cover Fit the parts in the reverse order 2 Tighten the two knobs by hand 1529686 R 8 4 2 A A o Transport Making the batteries accessible WARNING Fire and burn hazard due to short circuit at battery poles DO NOT short circuit the battery poles with a tool or metal parts of the wheelchair Make sure that the battery pole caps are attached at all times when you are not working on the battery poles CAUTION Risk of crushing The batteries are very heavy There is a risk of hand injury Be aware that the batteries are very heavy Handle the batteries with care Be careful when handling small parts such as screws and washers during disassembly Place the small parts down in a way that makes it easy to reassemble them in the correct order 89 Invacare Storm Series 2 90 Remove the rear cover as described in chapter 8 4 1 Opening the rear cover page 89 Pull the snap fitting 1 beside the power module backwards Lift the power module with the holder and remove the mounting from the battery cap flap P
59. h serious injury or damage Incorrect repair and or servicing of this mobility device performed by users caregivers or unqualified technicians can result in death serious injury or damage DO NOT attempt to carry out maintenance work that is not described in this user manual Such repair and or service MUST be performed by a qualified technician Contact a dealer or Invacare technician A CAUTION Risk of accident and loss of warranty if maintenance is insufficient For reasons of safety and in order to avoid accidents which result from unnoticed wear it is important that this mobility device undergoes an inspection once every year under normal operating conditions see inspection plan contained in service instructions Under difficult operating conditions such as daily travel on steep slopes or in the case of use in medical care cases with frequently changing mobility device users it would be expedient to carry out intermediate checks on the brakes accessories and running gear If the mobility device is to be operated on public roads the vehicle driver is responsible for ensuring that it is in an operationally reliable condition Inadequate or neglected care and maintenance of the mobility device will result in a limitation of the manufacturer s liability 2 6 Safety information regarding changes and modifications to the mobility device A DANGER Risk of serious injury or damage Use of incorrect or
60. hers Assembly ea Pull the seat support to the required length so that the Allen screws 5 can be inserted in the holes in accordance with the table see above Insert the Allen screws 5 including washers again and tighten them If necessary replace the seat support plate 2 in accordance with the table see above Put the seat support plate 2 back in position Fit the two Allen screws 7 which are located at the front of the seat support and connect them with the crossmembers 4 Fit the two Allen screws 8 which are located at the rear of the seat support and connect them with the crossmembers 4 It may be necessary to use other holes in the 3 hole pairs for the screws than you did while dismantling the old plate Fit the two Allen screws 9 at the front of the seat support plate Refit all the parts you have removed 53 Invacare Storm 4 Series 5 12 Backrest unit with ergonomic length 5 13 Adjusting the suspension and the shock compensation Easy Adapt absorbance 5 12 1 Adjusting the width O I 19 Dl 7i 54 Taking the user weight into account the Storm 4 suspension and shock absorbance can be individually adjusted to a softer setting for Also refer to the previous chapter entitled 5 11 1 Adjusting more comfort and less shock absorbance or a harder setting for a seat width page 50 harder suspension and more support These adjustments should The seat can be adjusted in stages between
61. ht adjustable legrests are operated using the remote Refer to the separate user manual for your remote for more information 5 18 3 Adjusting the length of the legrest CAUTION Risk of injury due to incorrect adjustment of the footrests and legrests Before and during every journey it is imperative to ensure that the legrests contact neither the caster wheels nor the ground Y Tools ol e 10mm open ended spanner Press the unlocking button I and swivel the legrest outward 2 Remove the legrest in an upward direction 5 18 2 Setting the angle CAUTION Risk of crushing Do not reach inside the swivelling range of the legrest 1529686 R 69 Invacare Storm Series Use the spanner to loosen the screw 1 5 18 5 Adjusting the height of the calf pad 2 Adjust to the desired length 3 Re tighten the screw 1 Tools 0 4mm Allen key 5 18 4 Adjusting the depth of the calf pad The depth of the calf pad can be adjusted via the holding plate The holding plate hole combinations allow 5 different depth settings 19 Tools ol e 10mm open ended spanner Use the Allen key to loosen the screws 1 2 Adjust to the desired position 3 Re tighten the screws 5 18 6 Unlocking and swivelling the calf pad backward when alighting Use the open ended spanner to loosen the nut 1 and remove 2 Adjust to the desired depth Please observe that the round holes are intended for the calf pad
62. ic plugs are firmly inserted into their sockets CAUTION Damage to wheelchair caused by one sided loading on lifter pillar One sided loading occurs if the seat is raised and or tilted Always return your seat backrest to the upright position and the seat tilting to the horizontal position before ascending slopes Never subject the lifter pillar to continuous single sided loading The raising and tilting function of the seat only provides additional rest positions 1529686 R o Important information regarding speed reduction I with raised lifter If the lifter has been raised above a certain point the drive electronics considerably reduces the speed of the wheelchair If speed reduction has been activated drive mode can only be used to carry out minor movements of the wheelchair and not for regular driving To drive normally please lower the lifter until the speed reduction has been deactivated again 2 8 Safety information on wheelchairs with Recaro seats and AJ Optimist seats CAUTION Risk of injury if the wheelchair tips over The center of gravity of a Recaro seat or AJ Optimist seat is higher than that of other seats These seats are also heavier than other seating systems The backrest can be leaned back 90 and 60 respectively For these reasons there is an increased risk of tipping over Never lean the backrest backward more than 30 degrees and never exceed 5 when driving the wheelchair
63. improper replacement service parts may cause injury or damage Replacement parts MUST match original Invacare parts Always provide the wheelchair serial number to assist in ordering the correct replacement parts 1529686 R CAUTION Risk of injuries and damage to mobility device due to unapproved components and accessory parts Seating systems additions and accessory parts which have not been approved by Invacare for use with this mobility device can affect the tipping stability and increase tipping hazards Only ever use seating systems additions and accessory parts which have been approved by Invacare for this mobility device Seating systems which are not approved by Invacare for use with this mobility device do not under certain circumstances comply with the valid standards and could increase the flammability and the risk of skin irritation Only use seating systems that have been approved by Invacare for this mobility device Electrical and electronic components which have not been approved by Invacare for use with this mobility device can cause fire hazards and lead to electromagnetic damage Only ever use electrical and electronic components which have been approved by Invacare for this mobility device Batteries which have not been approved by Invacare for use with this mobility device can cause chemical burns Only ever use batteries which have been approved by Invacare for thi
64. in in the designated borehole 2 and use a hammer to knock on this lightly The clamping mechanism in Loosen the screw 1 using the Allen key the interior of the footrest will be released by this Repeat the 4 Set the desired angle procedure from the other side of the footrest if necessary 5 Re tighten the screw 5 16 3 Setting the end stop of the footrest Tools 9 ol e 6mm Allen key e 10mm open ended spanner 60 1529686 R Adjusting the mobility device to the user s seating posture The end position of the footrest is determined by means of a rubber stop I Use the Allen key to loosen the screw I and swivel the footrest upward in order to access the rubber stop The rubber stop can be screwed in or out A or pushed up or down B Use the open ended spanner to loosen the counternut 1 1529686 R 6l Invacare Storm Series 5 Move the rubber stop to the desired position 6 Re tighten the counternut 7 Move the footrest to the desired position 8 Re tighten the screw 62 5 16 4 Adjusting the length of the footrest CAUTION A Risk of injury due to incorrect adjustment of the footrests and legrests Before and during every journey it is imperative to ensure that the legrests contact neither the caster wheels nor the ground 19 Tools Dl e 5 mm Allen key Use the spanner to loosen the screw 1 2 Adjust to the desired length 3 Re tighten the screw 5 17 V
65. ing EN 1021 2 and ISO 7176 14 It was also tested successfully according to EN 60529 IPX4 as to its resistance to spray water and is therefore well suited for weather conditions such as typical European weather conditions When equipped with an appropriate lighting system the vehicle is suitable for use on public roads 1 6 Indications The use of this power wheelchair is recommended for the following indications e The inability or a greatly restricted ability to walk within the scope of the basic requirement to be able to move within one s own four walls e The need to leave the dwelling place in order to get some fresh air during a short walk or to reach those places generally to be found at close distance to the dwelling and where everyday business is carried out Provision of power wheelchairs for interior and exterior areas is advisable if the use of hand operated wheelchairs is no longer possible on account of the disability yet proper operation of an electromotive drive unit is still practicable 8 I 7 Usability Only use a mobility device when it is in perfect working order Otherwise you might put yourself and others at risk The following list does not claim to be exhaustive It is only intended to show some of the situations that could affect the usability of your mobility device In certain situations you should immediately stop using your mobility device Other situations allow you to use the mobility device to
66. iving is 5 13 2 Disabling the suspension and shock absorbance You can disable the suspension and shock absorbance so that they are no longer working Move the lever from Active open lock symbol to Inactive closed lock symbol Right Left The works setting for the wheel is the middle position From here the shock absorbance can be adjusted to be softer or harder in 10 levels in either direction The suspension and shock absorbance are disabled 1529686 R 55 Invacare Storm 4 Series Adjusting the shock absorbance harder Turn the wheel to the plus sign to set harder shock absorbance 10 is the hardest level of shock absorbance Adjusting the shock absorbance softer Turn the wheel to the minus sign to set softer shock absorbance 10 is the softest level of shock absorbance 56 5 14 Center mounted legrests Electric legrest Consult the user manual for your remote for information about electrical adjustment The electric legrest can be lowered completely to assist getting out of the wheelchair To do so move your seat into the correct position by lowering the lifter or by means of a negative seat angle tilted slightly to the front 5 14 1 Lowering the electric legrest completely to assist getting out of the wheelchair Misuse may destroy the legrest Please read and carefully follow the instructions below 1529686 R Getting in out
67. lace the power module and the mounting on top of the battery compartment or actuator module if applicable Use the strap 3 to pull the batteries 1 and the battery carrier 2 forward as far as possible 8 4 3 Removing Installing the batteries 19 Tools ol e mm socket spanner 1529686 R Removing the batteries 2 OF Se Make the batteries accessible as described in chapter 8 4 2 Making the batteries accessible page 89 Remove the pole caps I from the accessible battery 3 Remove the pole screws located under the pole caps using an mm socket spanner Remove the connection cable 4 and the fuse cable 2 Lift the battery from the battery carrier Pull the second battery forward using its strap Disconnect the cables of the second battery as well Lift the second battery from the battery carrier Fitting the batteries Fit the batteries in the reverse order Ensure that the connectors and sockets in the battery compartment are fitted correctly There is a polarity diagram in the rear cover 1529686 R Transport 9 Invacare Storm Series 9 Maintenance 9 1 Maintenance introduction The term Maintenance means any task performed to ensure that a medical device is in good working order and ready for use as intended Maintenance encompasses different areas such as everyday care and cleaning inspection checks repair tasks and refurbishment i Have your vehicle checked onc
68. len screw 1529686 R Shift the remote forwards or backwards to the desired distance Adjusting the mobility device to the user s seating posture 5 2 3 Swivelling the remote to the side If your mobility device is fitted with a swing away remote holder then the remote can be moved away to the side for example to drive up close to a table 5 3 Adjustment options for standard armrests 5 3 1 Changing the arm support position 19 Tools ol e x Allen key 3 mm The arm support has 2 possible positions 29 Invacare Storm Series To change the position of the arm support loosen the screw 1 and remove it 2 The position of the arm support is adjusted by selecting a combination of screw holes in the arm support and the drill holes in the fixing plate 3 Reposition the screws and tighten 5 3 2 Setting the height of the armrests Y Tools il 3mm Allen key Unscrew screw with Allen key 2 Adjust armrest to required height 3 Retighten the screw 30 5 3 3 Adjusting the width of the armrests WARNING A Serious injury hazard if one of the armrests falls out of its bracket because they have been adjusted to a width which exceeds the permissible value The width adjustment is fitted with small stickers with markings and the word STOP The armrests must never be pulled out further than the point at which the word STOP is completely legible Always tighten the fixing screws
69. ly If inspection Item Inspection check is not passed Check for damage and wear Contact your ae dealer parts Removable Check whether the legrests can Contact your legrests be fixed securely and whether dealer the loosening mechanism is properly operable Check that all adjustment Contact your options function properly dealer Casters Check that casters rotate and Contact your swivel freely dealer Drive wheels Check that the drive wheels Contact your rotate without wobbling It is dealer easiest to have someone stand behind the mobility device and observe the drive wheels as you drive away from them to do this Electronics Check all cables for damage and Contact your and all connecting plugs for snug fit dealer connectors It is confirmed by stamp and signature that all jobs listed in the inspection schedule of the service and repair instructions have been properly performed The list of the inspection jobs to be performed can be found in the service manual which is available through Invacare 1529686 R Invacare Storm Series Delivery Inspection Ist Annual Inspection Stamp of authorized dealer Date Signature Stamp of authorized dealer Date Signature 2nd Annual Inspection 3rd Annual Inspection Stamp of authorized dealer Date Signature Stamp of authorized dealer Date Signature 94 1529686 R Maintenance 4th Annual Inspection 5th Annual Inspection Stamp of authorized
70. nd the electronics can be switched on again It can however take up to five minutes until the electronics has cooled down enough for the drives to apply their full performance If the drive is blocked due to an insurmountable obstacle for example a curb or similar which is too high and the driver attempts to run the drive for more than 20 seconds against this obstacle the electronic system switches the drives off to avoid damage The status display shows a corresponding flash code please refer to the user manual for your remote If you switch the drive electronics off and then on again the error message is deleted and the electronics can be switched on again o A defective main fuse may be replaced only after checking Il the entire electric system An specialized Invacare dealer must perform the replacement You can find information on the fuse type in Technical data page 102 7 2 Batteries Power is supplied by two I2 V batteries The batteries are maintenance free and only need regular charging 80 In the following you find information on how to charge handle transport store maintain and use batteries 7 2 1 General information on charging New batteries should always be fully charged once before their first use New batteries will be at their full capacity after having run through approx 10 20 charging cycles break in period This break in period is necessary to fully activate the battery for maximum performanc
71. nformation on a Recaro seat or AJ Optimist seat refer to the separate user manuals that come with the seats 5 2 Adjustment possibility for remote The following information is valid for all seating systems A CAUTION Risk of the remote being pushed backwards during an accidental collision with an obstacle such as a doorframe or table and the joystick being jammed against the armpad if the position of the remote is adjusted and all screws are not completely tightened This will cause the mobility device to drive forward uncontrollably and potentially injure the mobility device user and any person standing in the way When adjusting the position of the remote always make sure to tighten all screws securely If this should accidentally happen immediately switch the mobility device electronics OFF at the remote CAUTION Risk of injury When leaning on the remote for example when transferring into or out of the wheelchair the remote holder may break and the user may fall out of the chair Never lean on the remote as a support for for example transfer 1529686 R 5 2 1 Adjusting the remote for the length of the user s arm Loosen wing bolt 2 3 Retighten the bolt 5 2 2 Adjusting the height of the remote only for swing away remote supports 19 Tools ol e 6mm Allen key Loosen Allen screw 2 Adjust remote to desired height 3 Re tighten Al
72. ng the calf pad to the calf width of the user The calf pad of the legrest can be adapted to the user s calf width by bending apart or together 1529686 R Bending the calf pad to the desired width 5 15 4 Adjusting the angle of the foot plate 1Y Tools ol 5mm socket head spanner AS NA Fold up the foot plates in order to access the adjusting screws 2 Use the socket head spanner to adjust the adjusting screws 1 3 Fold the foot plate down again 1529686 R Adjusting the mobility device to the user s seating posture 5 16 Vari F footrest 5 16 1 Swivelling the footrest legrest outward and or removing The small unlocking button is located on the upper section of the footrest legrest When the footrest legrest is unlocked it can be swivelled inward or outward when getting into the wheelchair as well as being removed completely Press the unlocking button I and swivel the footrest legrest outward 2 Remove the footrest legrest in an upward direction 5 16 2 Setting the angle CAUTION Risk of injury due to incorrect adjustment of the footrests and legrests Before and during every journey it is imperative to ensure that the legrests contact neither the caster wheels nor the ground 59 Invacare Storm Series I9 Tools 3 il e 6mm Allen key Loosen the screw I using the Allen key 2 If the footrest cannot be moved after loosening the screw position a metal p
73. o 25 Nm Ensure that the tire outer is seated correctly 8 Pump the wheel up to its prescribed air pressure Refer to Technical data page 102 9 Check that the tire is seated correctly once again 10 Screw the valve cap back on Pa 9 7 3 Repairing a flat front tire pneumatic tire 3 00 6 19 Tools ol e 5 mm Allen key 24mm open end spanner e Repair kit for inner tubes or a new inner tube e Talcum powder Remove the wheel Jack the vehicle up and place a block of wood underneath it to prop it up Remove the plastic cap 1 Loosen and remove the nut 2 using the open end spanner Remove the washer 3 Take the wheel off of the fork assembly ni gale acta Pog 99 Invacare Storm Series i Re assembly is done in reverse order Make sure that the wheel is put back on the same side it was on and that it runs in the same direction it did before it was removed Repair the flat tire A A 100 CAUTION Risk of explosion The wheel will explode if you do not let the air out of the tire before removing the wheel Always let the air out of the tire before removing it press in the pin in the middle of the valve CAUTION Risk of injury If the wheel has been insufficiently tightened during assembly it can become loosened during driving When reassembling the drive wheels tighten the Allen screws at a torque of 30 Nm Secure all screws using a suitable blocker e g
74. o a vehicle A WARNING The mobility device is in danger of tipping over if it is transferred to a vehicle while the driver is still seated in the mobility device Transfer the mobility device without the driver whenever possible If the mobility device with the driver has to be transferred to a vehicle using a ramp ensure that the ramp does not exceed the maximum safe slope refer to Technical data page 102 If the mobility device has to be transferred to a vehicle using a ramp that does exceed the maximum safe slope refer to Technical data page 10 a winch must then be used An attendant can then safely monitor and assist the transfer process Alternatively a platform lift may be used Ensure that the total weight of the mobility device including the user does not exceed the maximum permitted total weight for the ramp or platform lift The mobility device should always be transferred to a vehicle with the backrest in an upright position the seat lifter lowered and the seat tilt in the upright position refer to Driving up and down gradients 1529686 R WARNING Risk of injury and damage to the mobility device If the mobility device is to be transferred to a vehicle via a lift when the remote is turned on there is a risk that the device may act erratically and fall off the lift Before transferring the mobility device via a lift turn off the product and disconnect either the b
75. oduction 02 00 e ee 92 9 2 Cleaning the mobility device 4 92 97 3 Inspection checks 520i e822 de ieee gored ee aS 92 9 3 1 Before each use of the mobility device 92 Iaz Week eie r Go ei ean este ee EE ent te Shs 93 M53 gt MONDI Yere tye ok ae ee hg le ee ate ha Ss eos 93 9 3 4 Inspections performed 00 ee eee 93 9 4 Short term storage cee ee eee ee ees 95 9 9 LONS LEMniStOrages s nde een ce bh beth eoee ee teas 95 9 6 Disconnect the power module 2 000 96 97 Repair Instructions eiseres eto ati ea ee E ees 97 9 7 1 Repairing tire punctures wheel rim type 3 00 8 97 9 7 2 Repairing punctures drive wheel with True Track Plus motor and pneumatic tires 98 9 7 3 Repairing a flat front tire pneumatic tire 3 00 6 99 IOAfter Use fica s teats bore kine eg atda eee ee eae IOI IOV Reconditioning 4 a1s Ate ecie siete sce hese eee E 10I 10 2 DISDOSall so 445 2975 oer a E ack Bee 10 lI Tech icaldata ese sessers renren a wa 102 II I Technical specifications 0 0 0 eee eee eee 102 General I I Introduction Thank you for choosing an Invacare product This user manual contains important information about the handling of the product In order to ensure safety when using the product read the user manual carefully and follow the safety instructions Please note that there may be sections in this
76. of breaking down in adverse weather conditions i e extreme cold in an isolated area If you are a user with severely limited mobility we advise that in the case of adverse weather conditions DO NOT attempt a journey without an accompanying attendant WARNING Risk of injury if your foot slides off the footrest and gets caught underneath the mobility device when it is in motion Make sure each time before you drive the mobility device that your feet are squarely and securely in place on the footplates and that both legrests are properly locked into place WARNING Risk of serious injury or damage Operating the mobility device with a ground clearance of less than 76 mm between the footplate and ground floor may cause serious injury or property damage ALWAYS maintain a minimum of 76 mm between the bottom of the footplate and ground floor to ensure proper ground clearance while the mobility device is in motion If necessary adjust the footplate height to achieve proper ground clearance After footplate height adjustment if the mobility device dips forward and the footplates touch the ground while in motion please contact your dealer for an inspection and avoid use of the mobility device if possible Safety WARNING Risk of injury if you collide with an obstacle when driving through narrow passages such as doorways and entrances Drive through narrow passages in the lowest driving mode and with du
77. of the wheelchair Set the lifter and tilt to a comfortable position 2 Put your feet on the footplate and pull the lever 1 The footplates will move smoothly down to the floor 3 Now you can get in out of the wheelchair Lifting up the footplates You are sitting in the wheelchair 2 Put your feet beside the footplates 1529686 R Adjusting the mobility device to the user s seating posture Pull the lever 1 The footplates rise up automatically 4 Let go the lever and put your feet on the footplates Adjusting the legrest Risk of damage to the legrest Always make sure that the footplates are fully raised to the uppermost position before adjusting the angle of the legrest Disregarding this advice will cause damage to your legrest 57 Invacare Storm Series Now you can adjust the angle of the legrest 5 15 Center mounted legrests Adjustable legrest 5 15 1 Adjusting the angle 19 Tools ol e 10mm open ended spanner 58 Use the open ended spanner to loosen the counternut 1 2 Move the legrest to the desired position by turning the spindle 2 3 Tighten the counternut 5 15 2 Adjusting the length of the legrest 19 Tools 0 I e 5mm socket head spanner L l Use the socket head spanner to loosen the fastening screws 1 2 Slide the foot support to the desired height 3 Tighten the fastening screws 5 15 3 Adjusti
78. oring system belts 2 Secure the mobility device by tensioning the belts in accordance with the anchoring system manufacturer s user manual 1529686 R Transport 8 3 2 How the user is secured within the wheelchair A CAUTION There is a risk of injury if the user is not properly secured within the mobility device Even if the mobility device is fitted with a postural belt this is no substitute for a proper safety belt which complies with ISO 10542 in the transport vehicle Always use the safety belt installed in the transport vehicle Safety belts must be in contact with the user s body They must not be held at a distance from the user s body using parts of the mobility device such as armrests or wheels Safety belts must be pulled as tightly as possible without causing the user discomfort Safety belts must not be positioned while twisted Ensure that the third seat belt anchorage point is not fixed directly to the vehicle floor but to one of the vehicle uprights CAUTION Injury hazard during use of the mobility device as a vehicle seat if a headrest is wrongly adjusted or not installed This can cause the neck to be hyperextended during collisions A headrest must be installed The headrest optionally supplied for this mobility device by Invacare is perfectly suitable for use during transport The headrest must be adjusted to the user s ear height 87 Invacare Storm Seri
79. ort Disassembly Remove the armrests 2 Remove the seat cushion 3 Remove the cover plates 1 4 Undo and remove the two Allen screws 8 which are located on the side at the rear of the seat support plate and connect these to the crossmembers 4 52 1529686 R 5 11 4 Adjusting the seat depth with replacing the seat oO plate EZ Exploded drawing of seat support Disassembly Remove the legrests 2 Remove the armrests 3 Remove the seat cushion 4 Remove any cable ties which hold cables from the remote or lighting which have been fitted Remove the cables from any clips which have been glued on 5 Undo the cap nuts on the headlight holders with an 8 mm jaw spanner 1529686 R i II 2 3 Adjusting the mobility device to the user s seating posture Place the headlights including their holders safely on the rear section of the battery box cover Remove the cover plates 1 Undo the two Allen screws 9 at the front on the seat support plate and remove them Undo the two Allen screws 7 which are located on the side at the front of the seat support plate and connect these to the crossmembers 4 Undo the two Allen screws 8 which are located on the side at the rear of the seat support plate and connect these to the crossmembers 4 Remove the seat support plate 2 Repeat these operations on the other side of the seat Undo and remove the two Allen screws 5 including was
80. osition before moving off Always return the antitippers to the driving position before moving off see the figure below Make sure that the locking pin is fully engaged 1529686 R Driving position Parking position Folding the antitipper down Pull out the locking pin to release the antitipper 2 Fold the antitipper down The mobility device is now shorter Folding the antitipper up Fold the antitipper upwards until the locking pin audibly engages The antitipper is functional again 6 8 Use on public roads If you wish to use your mobility device on public roads and lighting is required by national legislation then your mobility device needs to be fitted with an appropriate lighting system Contact your Invacare dealer if you have any questions 6 9 Pushing the mobility device in freewheel mode The motors of the mobility device are equipped with automatic brakes preventing that the mobility device starts rolling out of control when the remote is switched off When pushing the mobility 1529686 R Usage device manually whilst freewheeling the magnetic brakes must be disengaged 7 Pushing the mobility device by hand may require more Il physical force than expected more than 100 N The necessary force nevertheless complies with the requirements of ISO 7176 14 6 9 1 Disengaging motors conventional motors CAUTION Risk of injury from hot motor surfaces Avoid touching the
81. properly once adjustments have been completed STOPI 19 Tools ol e 8mm Allen key Loosen screw 1 Adjust armrest to required position Retighten the screw Repeat this procedure for the second armrest RWN 1529686 R 5 4 Adjustment options for parallel sliding armrests 5 4 1 Setting the height of the parallel sliding armrests The height of the parallel sliding armrest is set using the armrest angle Set the angle for the armrest 3 Retighten the knob After adjusting the armrest height the angle of the armpad needs to be adjusted Refer to 5 4 2 Adjusting the angle of the armpad on the parallel sliding armrests page 31 1529686 R Adjusting the mobility device to the user s seating posture 5 4 2 Adjusting the angle of the armpad on the parallel sliding armrests 19 Tools ol e 5 mm Allen key lt Release the bolts to adjust the armrest angle 1 with the Allen key Set the angle for the armrest 3 Re tighten the bolts Make sure that the Nordlock washers used are re inserted 5 4 3 Adjusting the width of the parallel sliding armrests The parallel sliding armrests can be adapted to the backrest in eight widths 3 Invacare Storm Series I9 Tools 2 il 4mm Allen key Adjust the armrest width The possible positions for the armrest are predefined by the drill holes in the torque support and the armrest axel Insert the locating pin Retighten the screw
82. rate the mobility device at the same time DO NOT sit in the mobility device while charging the batteries Switch off the mobility device 2 Connect the battery charger to the charger socket 3 Connect the battery charger to the power supply 7 2 4 How to disconnect the mobility device after charging Once charging is complete first disconnect the battery charger from the power supply then disconnect the plug from the remote 7 2 5 Storage and Maintenance Follow the instructions listed below to ensure safe use and longevity of the batteries 8 Invacare Storm Series Always store the batteries fully charged Do not leave the batteries in a low state of charge for an extended length of time Charge a discharged battery as soon as possible In case your mobility device is not used for a longer period of time that is more than two weeks the batteries must be charged at least once a month to maintain a full charge and always be charged before use Avoid hot and cold extremes when storing We recommend to store batteries at a temperature of I5 C Gel and AGM batteries are maintenance free Any performance issues should be handled by a properly trained mobility device technician 7 2 6 Instructions on using the batteries 82 CAUTION Risk of damaging the batteries Avoid ultra deep discharges and never drain your batteries completely Pay attention to the Battery Charge Indicator Charg
83. red position 3 Re tighten the screws Loosen the locking screw I on both sides with the mm Allen key 72 1529686 R 6 Usage 6 1 Driving o The maximum load capacity that is stated in the technical Il data only states that the system is designed for this mass in total However this does not mean that one can sit a person with this body weight in the mobility device without restrictions Attention must be paid to the body proportions such as height weight distribution abdominal belt leg and calf strap and seat depth These factors have a strong influence on driving features such as tilt stability and traction The permissible axle loads in particular must be adhered to refer to Technical data page 109 It may possibly be necessary to carry out adaptations to the seat system 6 2 Before driving for the first time Before you take your first trip you should familiarize yourself well with the operation of the mobility device and with all operating elements Take your time to test all functions and driving modes ji If installed make sure to properly adjust and use the postural belt each time you use the mobility device Sitting comfortably Driving safely Before each trip make sure that e You are within easy reach of all operating controls e The battery charge is sufficient for the distance intended to be covered e The postural belt if installed is in perfect order 1529686 R Usage e The rear mirror
84. retaining screw and the oblong holes for the aglet without thread DE 3 Screw the nut back on and tighten N H Press the calf pad straight down 70 1529686 R Adjusting the mobility device to the user s seating posture Unlock the legrest and swivel outward 5 n the ore ne barnes both set screws on the foot plate The calf pad swivels backward on its own djust to the desired angle 3 3 Re tighten the screws 5 18 8 Adjusting the angle and depth adjustable foot plate 19 Tools ol e 5 mm Allen key Lift leg over the heel strap and place on the ground 5 18 7 Adjusting the angle adjustable foot plate 2 Tools ol e 5mm Allen key Use the Allen key to loosen the set screw on the foot plate 1 2 Adjust the foot plate to the desired angle or depth 3 Re tighten the screw 1529686 R 7 Invacare Storm Series 5 19 Angle adjustable footboard 6 Adjust the footboard to the required angle OH N 7 Retighten the bolts i 1 Tools D e 125 Torx spanner 5 20 Adjusting the width of side mounted 5mm Allen key legrests l 9 Tools ol 13 mm open ended spanner Release the screws I with the Torx spanner and remove 2 Adjust to required width 3 Retighten the bolts The screws that allow width adjustment of side mounted legrests 4 Glue the anti slip rubber mat to the footboard are located under the seat 1 5 Loosen the screws using the open end spanner 2 Adjust the legrest to the desi
85. rom mounting slot via cut out 3 Insert hip pad bracket in other mounting slot 4 Tighten screws Remove hip pad with bracket turn upside down and reinstall 4 Insert friction link friction cap screw and tighten Via bracket 19 Tools il 5 mm Allen key 40 1529686 R 5 5 10 Adjusting the seat width The telescopic seat support can be adjusted in four stages The seat width can thus be adjusted together with the adjustable seat plate or the adjustable sling seat The description of how the width is adjusted is contained in the service instructions for this mobility device The service instructions can be ordered from Invacare However they contain instructions for specially trained service technicians and describe operations that are not intended for the end user 5 5 11 Adjusting the seat depth o The seat depth has a major influence on the selection of Il the center of gravity of the seat This impacts its dynamic stability If you make a major change to the seat depth the center of gravity of the seat must also be adjusted See Adjusting the center of gravity of the seat in the service instructions for this mobility device The service instructions can be ordered from Invacare However they contain instructions for specially trained technicians and describe operations that are not intended for the end user The numbers on the scale on the seat serve as a guide They do not stipulate any dimensions such as
86. rom sources of heat such as heaters and direct sunlight If the battery charger overheats charging current will be reduced and the charging process delayed 7 2 3 How to charge the batteries Refer to the user manuals for your remote and battery charger for the position of the charging socket and further information about charging the batteries A A A 1529686 R WARNING Risk of explosion and destruction of batteries if the wrong battery charger is used Only ever use the battery charger supplied with your mobility device or a charger that has been approved by Invacare WARNING Risk of electric shock and damage to the battery charger if it gets wet Protect the battery charger from water Always charge in a dry environment WARNING Risk of short circuit and electric shock if the battery charger has been damaged Do not use the battery charger if it has been dropped or damaged A Electrical system WARNING Risk of electric shock and damage to the batteries NEVER attempt to recharge the batteries by attaching cables directly to the battery terminals WARNING Risk of fire and electric shock if a damaged extension cable is used Only ever use an extension cable if it is absolutely necessary In case you must use one make sure it is in good condition WARNING Risk of injury if using the mobility device during charging DO NOT attempt to recharge the batteries and ope
87. ry or death if it is not avoided CAUTION Indicates a hazardous situation that could result in minor or slight injury if it is not avoided IMPORTANT Indicates a hazardous situation that could result in damage to property if it is not avoided o Gives useful tips recommendations and information I for efficient trouble free use This product complies with Directive 93 42 EEC concerning medical devices The launch date of this product is stated in the CE declaration of conformity Tools This symbol identifies a list of various tools 1 components and items which you will need in order to carry out certain work Please do not attempt to carry out the work if you do not have the listed tools available I 3 Type classification This vehicle has been classified according to EN 12184 as a class B mobility product for indoor and outdoor areas It is therefore Invacare Storm Series compact and agile enough for indoor areas but also able to overcome many obstacles in outdoor areas 1 4 Intended use This mobility device was designed for persons whose ability to walk is impaired but who are still in terms of their eyesight and physically and mentally able to operate an electric mobility device 1 5 Regulations The vehicle was successfully tested according to German and international standards as to its safety It satisfies the requirements according to RoHS 201 1 65 EU REACH 1907 2006 EC and DIN EN 12184 includ
88. s mobility device o Safety CAUTION Risk of injuries and damage to the mobility device if unapproved backrests are used A retrofitted backrest which is not approved by Invacare for use with this mobility device may overload the backrest tube and thus increase the risk of injuries and of damage to the mobility device Please contact your Invacare specialist dealer who will perform risk analyses calculations stability checks etc to ensure that the backrest can be used safely CE marking of the mobility device The conformity assessment CE marking was carried out in accordance with Directive 93 42 EEC and only applies to the complete product The CE marking is invalidated if components or accessories are replaced or added that have not been approved for this product by Invacare In this case the company that adds or replaces the components or accessories is responsible for the conformity assessment CE marking or for registering the mobility device as a special design and for the relevant documentation Invacare Storm Series O I Important information about maintenance work tools Some maintenance work which is described in this manual and can be carried out by the user without problems require the correct tools for proper work If you do not have the correct tool available we do not recommend that you try to carry out the relevant work In this case we urgently recommend that you
89. s much as possible 5 Check your belt every week to ensure that it is still in good working condition to ensure it has no damage or wear and that it is fixed properly to the mobility device If the belt is only fastened with a bolted connection ensure that the connection has not loosened or come undone You can find more information about maintenance work on belts in the service manual which is available from Invacare 4 2 Using the cane holder If your mobility device is fitted with a cane holder it can be used for the safe transport of a walking cane underarm or forearm crutches The cane holder consists of a plastic container bottom and a Velcro fastener top 25 Invacare Storm Series A CAUTION Risk of injury A walking cane or crutches that are not secured during transport on the user s lap for example can cause injury to the user or other persons During transport walking canes or crutches should always be secured using a cane holder Open the upper Velcro fastener 2 Place the lower end of the walking cane or the crutches in the container at the bottom 3 The walking cane or the crutches can be secured at the upper end using the Velcro fastener 4 3 Using the KLICKfix adapter Your mobility device can be fitted with the mini adapter from the Rixen Kaul KLICKfix system To this you can attach various accessories such as the cellphone case supplied by Invacare which you can use to tran
90. s or where there is a risk of skidding such as wet pavement ice etc Avoid trying to get out of the vehicle on an incline or a gradient Always drive straight in the direction the road or path you are on goes rather than attempting to zigzag Never attempt to turn around on an incline or a slope CAUTION Braking distance is much longer on a downhill slope than on even terrain Never drive down a slope that exceeds the maximum safe slope refer to Technical data page 02 O I Important information about regulating the actuator functions on gradients Your mobility device is fitted with an angular sensor which guarantees tipping stability The sensor measures the actual angle of the drive unit and prevents any further decrease in stability by restricting the functionality of the adjustment actuators If this safety function is activated the backrest and the seat tilting can only be moved forwards and the lifter can only be lowered Reposition your mobility device on level ground so that the actuators can function normally again 6 7 Using foldable antitippers Where space is restricted e g in an elevator or when being transported in a car the mobility device may be too long Foldable antitippers can be useful here These can only be operated by an attendant as they are positioned beyond the reach of the user A CAUTION Risk of tipping if the antitippers are not returned to the driving p
91. s used are re inserted 34 5 5 Adjustment options for the Modulite seat unit 5 5 1 Adjusting the height of the armrests Loosen wing screw 2 Adjust armrest to desired height 3 Re tighten wing screw 5 5 2 Adjusting the width of the armrests WARNING Serious injury hazard if one of the armrests falls out of its bracket because they have been adjusted to a width which exceeds the permissible value The width adjustment is fitted with small stickers with markings and the word STOP The armrests must never be pulled out further than the point at which the word STOP is completely legible Always tighten the fixing screws properly once adjustments have been completed STOP 1529686 R ji Depending on the side the screw is accessible from the front or the rear iY Tools ol e 8mm Allen key Loosen screw 2 Adjust armrest to required position 3 Retighten the screw 4 Repeat this procedure for the second armrest 5 5 3 Adjusting the position of the armrest in depth 19 Tools ol e 6mm Allen key 1529686 R Adjusting the mobility device to the user s seating posture Loosen the screws and move the armrest lengthwise 2 Tighten the screws 5 5 4 Adjusting the height flip up armrest 4 LEE gt 7 C Loosen thumb screw 2 Adjust armrest to desired height Retighten thumb screw
92. shing the mobility device in freewheel mode WARNING Risk of injury if the mobility device is switched off while driving for example by pressing the On Off Button or disconnecting a cable due to it coming to an abrupt sharp stop If you have to brake in an emergency simply release the joystick which will bring you to a halt refer to the remote user manual for more information 1529686 R 1529686 R WARNING Risk of injury when transferring mobility device to a vehicle for transport with the occupant seated in it It is always better to transfer the mobility device to a vehicle without the occupant seated in it If the mobility device needs to be loaded up a ramp together with its driver ensure that the ramp does not exceed the maximum safe slope refer to Technical data page 102 If the mobility device does need to be loaded using a ramp which exceeds the maximum safe slope refer to Technical data page 10 then you must use a winch An attendant can safely monitor and assist the loading process As an alternative you can use a platform lift Ensure that the total weight of the mobility device including the user does not exceed the maximum permissible weight for the platform lift or winch if you are using WARNING Risk of falling out of the mobility device Do not slide forward on the seat do not lean forward between your knees do not lean backwards out over the top of the
93. sides loosen and remove the middle backrest screw 2 Set the required backrest angle in 7 5 steps Ensure that you set the same angle on both sides Re insert and tighten the screw 5 7 7 Adjusting the adaptable backrest padding There are two ways of adapting the backrest padding e Using a snap buckle which is accessible without having to remove the backrest cushion Please see Method I e With adjustment straps which are adjustable using Velcro Please see Method 2 Method 45 Invacare Storm Series Open the Velcro straps on the left hand side of the backrest cushion 2 Open the individual snap buckles 1 on the adjustment straps 3 Adjust the strap tension as required and then close the snap buckle again 4 Close the backrest cushion Velcro fastenings again Method 2 46 Remove the backrest cushion fixed with Velcro straps by pulling it up and away so that you can access the adjusting straps Adjust the tension of the individual straps as required 3 Replace the backrest cushion 1529686 R 5 8 Adjusting the headrest CAUTION Injury hazard during use of the mobility device as a vehicle seat if a headrest is wrongly adjusted or not installed This can cause the neck to be hyperextended during collisions A headrest must be installed The headrest optionally supplied for this mobility device by Invacare is perfectly suitable for use during transport The headrest mus
94. sport your cellphone sports glasses etc 26 Risk posed by unsecured accessories Accessories can fall off and get lost if they are not properly secured Check that the accessory is correctly locked in and seated securely every time you use the mobility device Risk of breakage due to excessive load The KLICKfix adapter can break if too great a load is applied The maximum permitted load on the KLICKfix adapter is kg Securing the accessory Push the accessory into the KLICKfix adapter The accessory locks in securely Removing the accessory Press the red button and remove the accessory The adapter can turn in 90 steps allowing you to attach an accessory from any of four different directions Please refer to the installation instructions which are available from your Invacare dealer or directly from Invacare More information on the KLICKfix system is available at http www klickfix com 4 4 Adjusting or removing the luggage carrier l Risk of damage as a result of collisions Parts of the mobility device may be damaged if the luggage carrier collides with the seat during seat angle or backrest adjustment Ensure that the luggage carrier is out of the range of both seat angle and backrest adjustment 1529686 R Risk of breakage due to excessive load The luggage carrier can break if too great a load is applied The maximum permitted load on the luggage carrier is 10 kg
95. t be adjusted to the user s ear height 5 8 1 Adjusting the position of the headrest or neckrest The adjustment of the position is the same for all headrests and neckrests 1529686 R Adjusting the mobility device to the user s seating posture 19 Tools ol e 5 mm Allen key Loosen the screws or the clamping lever Adjust the headrest or neckrest to the required position Retighten screws and clamping lever Loosen the Allen screw Slide the headrest left or right to the required position 6 Retighten the Allen screw UAWN 5 8 2 Adjusting the height of the headrest or neckrest The adjustment of the height is the same for all headrests and neckrests 47 Invacare Storm Series Loosen knob 2 Adjust headrest or neckrest to required height 3 Retighten knob 5 8 3 Adjusting the cheek supports Push the cheek supports inward or pull them out to the required position 48 5 9 Adjusting the trunk supports 5 9 1 Adjusting the width Loosen the handscrews 1 2 Adjust the trunk support to the required width 3 Retighten the handscrews again 5 9 2 Adjusting the height I9 Tools ol e 5 mm Allen key 1529686 R Adjusting the mobility device to the user s seating posture Open the zip Undo the screws 1 for the depth adjustment Adjust the trunk support to the required position Retighten the screws Close the zip again UAWN 5 10 Adjusting
96. t thread 3 Screw the nut back on and tighten 5 17 6 Adjusting the height of the calf pad Tools au A ee L9 ol 4mm Allen key Press the calf pad straight down 1529686 R 67 Invacare Storm Series Unlock the legrest and swivel outward The calf pad swivels backward on its own Lift leg over the heel strap and place on the ground 5 17 8 Adjusting the angle adjustable foot plate 2 Tools ol e 5mm Allen key 68 Use the Allen key to loosen both set screws on the foot plate 2 Adjust to the desired angle 3 Re tighten the screws 5 17 9 Adjusting the angle and depth adjustable foot plate 19 Tools ol e 5 mm Allen key Use the Allen key to loosen the set screw on the foot plate 1 2 Adjust the foot plate to the desired angle or depth 3 Re tighten the screw 1529686 R Adjusting the mobility device to the user s seating posture 5 18 Powered elevating legrests ADE legrests i CAUTION Risk of injury due to incorrect adjustment of the 5 18 1 Swivelling the legrest outward and or footrests and legrests removing Before and during every journey it is imperative to The small unlocking button is located on the upper section of the ensure that the legrests contact neither the caster legrest When the legrest is unlocked it can be swivelled inward wheels nor the ground or outward when getting into wheelchair as well as being removed completely The electrically heig
97. tal recycling The plastic parts are used for plastic recycling Electric components and printed circuit boards are disposed of as electronic scrap Exhausted or damaged batteries can be returned to your medical equipment supplier or Invacare Disposal must be carried out in accordance with the respective national legal provisions Ask your city or district council for details of the local waste management companies 1529686 R After Use 10I Invacare Storm Series Il Technical data 1 1 Technical specifications The technical information provided hereafter applies to a standard configuration or represents maximum achievable values These can change if accessories are added The precise changes to these values are detailed in the sections for the respective accessories O I Note that in some cases the measured values may vary up to 10 mm Permissible operating and storage conditions Temperature range for operation according to ISO 7176 9 S o E29 a F50 C Temperature range for storage according to ISO 7176 9 e 25 65 C with batteries e 40 65 C without batteries Electrical system Motors e 340 W conventional motors e 600 W True Track Plus motors Batteries e 2x 12 V 73 5 Ah C20 leakproof gel Main fuse e 80A Degree of protection IPX4 Charging device Output current e 8A 8 Output voltage e 24V nominal 12 cells 102 1529686 R Technical data Drive wheel tires
98. tric brakes to the manufacturer 2 4 Safety information on driving and freewheel mode A DANGER Risk of death serious injury or damage Malfunctioning joystick could cause unintended erratic movement resulting in death serious injury or damage If unintended erratic movement occurs stop using the wheelchair immediately and contact a qualified technician Invacare Storm Series WARNING WARNING Risk of injury if the mobility device tips over Risk of injury if the mobility device tips over Inclines and declines can only be travelled up to the continued maximum safe slope refer to Technical data page Never use the mobility device to transport more than 102 one person Always return the backrest of your seat or the seat Do not exceed the overall maximum permissible load tilt to an upright position before ascending slopes or the maximum load per axle refer to 1 Technical We recommend that you position the seat backrest data page 102 and the seat tilt if fitted slightly to the rear before Note that the mobility device will brake or accelerate descending slopes if you change the driving mode whilst the mobility Only ever drive downhill at a maximum of 2 3 of the device is in motion top speed Avoid abrupt braking or accelerating on gradients WARNING If at all possible avoid driving on wet slippery icy or J Risk of serious injury or damage oily surfaces such as snow
99. upport Remove the seat cushion 2 Remove the cover plates 1 1529686 R Adjusting the mobility device to the user s seating posture 3 Undo the two Allen screws 6 at the rear on the crossmember and remove them 4 Undo the two Allen screws 9 at the front on the seat support plate and remove them 5 Loosen the four Allen screws 7 and 8 which are located at the A 1524550 US front and back to the sides of the seat support plate to release Goines 3 tension so that the plate can be moved more easily Do not however remove these screws completely 6 Pull or push the seat support plate 2 the required width A scale 3 has been fitted to the bottom part of the seat support Holes used Holes used Seat Use this scale to read off the seat width in centimeters Eont ceii a rear ceal DDO 7 Repeat these operations on the other side of the seat kareo or ane order nate Ge NOW HENEN AU INE crew agan i no 1524550 no 1524555 required 5 11 2 Adjusting the seat depth SHORT o Also refer to the previous chapter entitled 5 11 1 Adjusting Il i order no seat width page 50 1526437 The seat depth can be adjusted in stages between 380 and 530 mm MEDIUM order no Ia Toos 1526438 ol 4mm Allen key e 8 mm jaw spanner LONG e oblique pliers e cable binder order no 1526439 Particular holes in the seat support must be used to the o screws depending on the required seat depth It may also be 2 A
100. us cable from the remote or the batteries from the system Drive or push your mobility device into the transport vehicle using a suitable ramp 8 3 Use of the mobility device as a seat in a vehicle i The following section does not apply to models or configurations which may not be used as a vehicle seat These are identified by the following labels on the lashing eyes 1529686 R Transport WARNING Risk of death or serious injury If a mobility device is secured using a 4 point tie down system available from a third party supplier and the curb weight of the mobility device exceeds the maximum weight for the system death or serious injury to the user and potential nearby occupant The actual weight of this wheelchair can exceed 140 kg A suitably strong and proven 4 point tie down system is available from Unwin Safety Systems Contact Unwin for more information on how to obtain such a system in your country Unwin Safety Systems Phone 44 0 1935 827740 Email sales unwin safety co uk Web www unwin safety com If compatible use the Docking Station system available separately as an alternative way to safely use this wheelchair as a vehicle seat Contact Invacare for more details WARNING Risk of injury Safety restraint devices must only be used when the wheelchair user s weight is 22 kg or more When the user weight is lower than 22 kg do not use the wheelchair as a seat in a vehicle 85
101. user manual which are not relevant to your product since this manual applies to all existing modules on the date of printing If you find that the font size in the print version of the user manual is difficult to read you can download it as a pdf from the Invacare website see back page of this manual The pdf can then be scaled on screen to a font size that is more comfortable for you This mobility device has been constructed for a large circle of users with different requirements The decision whether the model is suitable for the user may only be taken by medical specialists with appropriate expertise Invacare or their statutory representatives can accept no liability in cases in which the mobility device has not been adapted to suit the users handicaps Some maintenance and settings can be performed by the user or his hers attendants Certain adjustments do however require technical training and may only be carried out by your Invacare specialist dealer Refer to the Inspection checks chapter in 9 Maintenance page 92 Damages and errors caused by nonobservance of the user manual or as a result of incorrect maintenance are excluded from all guarantees 1529686 R General 1 2 Symbols in this manual In this manual warnings are indicated by symbols The warning symbols are accompanied by a heading that indicates the severity of the danger WARNING Indicates a hazardous situation that could result in A serious inju
102. ut the relevant work In this case we urgently recommend that you contact an authorised specialist workshop The following are instructions on maintenance and repairs that can be performed by the user For the specifications of spare parts please see Technical data page 102 or consult the service manual available from Invacare in this connection please see the addresses and phone numbers at the end of this user manual In case you require assistance please contact your Invacare dealer A A 1529686 R CAUTION Risk of damage or injury if the vehicle is accidentally set into motion during repairs Switch the power off ON OFF Button Engage the motors Secure the vehicle against rolling away by placing wedges under the wheels CAUTION Risk of hands and feet being crushed by the weight of the wheelchair Pay attention to your hands and feet Use the correct lifting techniques Maintenance 9 7 1 Repairing tire punctures wheel rim type 3 00 8 CAUTION Risk of injury If the wheel has been insufficiently tightened during assembly it can become loosened during driving When reassembling the drive wheels tighten the Allen screws at a torque of 30 Nm Secure all screws using a suitable blocker e g Loctite 243 2 Tools ol e Allen key 6 mm e Torque spanner e Repair kit for tire repair or a new inner tube e Talcum powder e Screw blocker Loctite e g Loctite 243
103. wly it could happen Il that the antitippers get stuck and lift the drive wheels off the ground A driving of the mobility device is then no longer possible Ascending obstacles with a curb climber Approach the obstacle or the curb slowly head on and at a right angle Stop in the following position 30 50 cm in front of the obstacle Check the position of the front wheels They must be in driving direction and at right angles to the obstacle Approach with full speed until the curb climber makes contact with the obstacle The impetus will lift both front wheels over the obstacle Keep at a consistent speed until the rear wheels have also passed over the obstacle 6 6 Driving up and down gradients For information concerning the maximum safe slope refer to Technical data page 102 75 Invacare Storm Series A 76 CAUTION Risk of tipping over Only ever drive downhill at a maximum of 2 3 of the top speed Avoid sudden changes of direction or abrupt braking when driving on slopes Always return the backrest of your seat or the seat tilt if adjustable seat tilt is available to an upright position before ascending slopes We recommend that you position the seat backrest or the seat tilt slightly to the rear before descending slopes Always lower the lifter if fitted to its lowest position before ascending or descending a slope Never attempt to ascend or descend a slope on slippery surface
104. y during transfer 3 Always switch your mobility device off 4 Always engage both motor locks clutches and free wheel hubs if fitted to prevent the wheels from moving 5 Depending on the armrest type of your mobility device detach the armrest or swivel it up 6 Now slide into the mobility device 74 Getting out of the mobility device Position your mobility device as close as possible to your seat 2 Align casters parallel to the drive wheels to improve stability during transfer Always switch your mobility device off 4 Always engage both motor locks clutches and free wheel hubs if fitted to prevent the wheels from moving 5 Depending on the armrest type of your mobility device detach the armrest or swivel it up 6 Now slide onto your new seat 6 5 Taking Obstacles 6 5 1 Maximum obstacle height You can find information about maximum obstacle heights in the chapter entitled Technical data page 102 OJ 6 5 2 Safety information when taking obstacles h CAUTION Risk of tipping over Never approach obstacles at an angle but at 90 degrees as shown below Approach obstacles with a gradient after it with caution If unsure whether the gradient is too steep or not move away from the obstacle and if possible try to find another location Never approach obstacles at an uneven and or loose ground Never drive with too low tire pressure For the recommended tire pressure refer to

Download Pdf Manuals

image

Related Search

Related Contents

Casio EX-Z1200 Digital Camera User Manual  EverFocus EAN850A surveillance camera  Samsung 713BM Kasutusjuhend  HBW-150 combo de bajo manual de instrucciones  NEC SB-01HC video splitter  Fiche Technique* BOIS RAMÉAL FRAGMENTÉ (BRF) DE SAULE  Westinghouse One-Light Indoor Wall Fixture 6102800 Instruction Manual  Minidatalogger - Manual de instrucciones  