1. Eg for 10 minutes input 010 for 5 minutes input 005 etc When the third digit is input the panel will give an accep tance tone and revert back to ENGINEER PROGRAMMING MODE Engineer Programming Note To comply with EN50301 1 siren time must be adjusted between 2 minutes 002 and a maxi mum duration of 1 5 minutes 015 14 Programming 2 06 Part Guard Exit Time Adjustment Part Guard set time is the maximum period of time between setting the alarm and leaving the protected area this is pre set at 5 seconds Press Zones 1 2 3 LEDs illuminate Part Guard Time Input a new time max 255 seconds Eg for 10 seconds input 010 for 25 seconds input 025 etc When the third digit is input the panel will give an accep Engineer tance tone and revert back to ENGINEER PROGRAMMING MODE Programming 2 07 Set Zones Disabled Isolated in Part Guard In this location enter zones to be Disabled Isolated part guard arming Press Enter zone numbers to be omitted the corresponding Zones Disabled LEDs will flash None To reset that zone toggle the corresponding zone Engineer Press Programming 2 08 Set Sleep Watch Zone Delay Activation Time In this location activation of a sleep watch zone will not activate a full alarm until after the zone delay time has timed out this is pre set at 15 seconds Press Zones 1 2 3 LEDs illuminate S W Delay Time Input a new time max 255 seconds Eg for 10 seconds input 010 for 25
2. STB ST6100 ST6550 amp ST6600 SAB 2 OV RT SAB 1 OV RT DIO Aala BELL STB ST6100 ST6550 amp ST6600 SAB 2 OV RT CI SAB 1 OV RT BELL STB ST6100 ST6550 amp ST6600 SAB2 OV RT ZZ ZI SAB 1 STB BELL OV RT SAB2 OV RT 2121 21212121010 SAB 1 OV RT BELL STB VORTEX BTO BTI HOLD HOLD TG STB RETURN CITADEL DEFENDER HOLD OFF SIREN RTN SIGNAL HOLD OFF STROBE COM VE STB 12V s TAMP 24 12 TAMP 24 STB Installation 1 14 Wiring Passive Infrared Detectors Single Passive Infrared Detector Consult Passive Infrared Detectors manufacturers installation instructions before wiring to control panel TAMPER If two or more Passive Infrared Detectors are wired to a zone wire power in parallel wire alarm and tamper in series 576100 ST6550 amp ST6600 Use 6 core multi stranded cable Terminal Connection Wire Colour AUX 1 Detector Positive 12 White AUX 1 Detector Negative OV Z1 Z6 Black 71 26 System Tamper ST6100 ST6550 amp ST6600 Three Passive Infrared Detectors Wired in Series Installation 1 15 Wiring System Tamper ST6100 ST6550 amp ST6600 AUX 1 SAB1 SAB2 TAMP 7 1 76 elelelelelelelelele 6 Core Cable 4 Core Cable 6 Core Cable 6 Core Cable 4 Core Cable 6 Core Cable 146 Wiring Magnetic Contacts
3. seconds input 025 etc When the third digit is input the panel will give an accep Engineer tance tone and revert back to ENGINEER PROGRAMMING MODE Programming Note If a sleep watch zone is activated a valid user code must be entered to stop activation sequence 2 09 Enable Sleep Watch Zones Automatic Rearm In this location after the user has pressed the sleep watch button to disarm sleep watch zones they will automatically rearm after the period of time programmed in location section 2 10 has timed out Press Zone 1 LED Flashing Sleep Watch automatic rearm enabled S W Rearm Toggle Key 4 to disable function Disabled Press and revert back to ENGINEER PROGRAMMING MODE mm ngineer Programming 2 10 Sleep Watch Zone Automatic Rearm Time In this location set sleep watch zones automatic rearm time this is pre set at 15 minutes Press Zones 1 2 3 LEDs illuminate S W Rearm Time Input a new time max 255 minutes Eg for 10 minutes input 010 for 25 minutes input 025 etc When the third digit is input the panel will give an Engineer tance tone and revert back to ENGINEER PROGRAMMING MODE Programming Programming 2 11 Enable Sleep Watch and Disarm Part Guard The Sleep Watch keypad can be programmed to arm and disarm part guard by pressing the Sleep button for 3 seconds Press Zone 1 LED Flashing Sleep Watch keypad disarm part i S W Disarm guard enabled Toggle Key 6 to disable function
4. 18 1Vac Maximum Total Current Rating 1 0 Ampere Recharge Backup Battery 12V Sealed Lead Acid 1 2 7 0Ah Environmental Operating Temperature 10 C 14 F to 50 C 122 F Storage Temperature 20 C 4 F to 60 C 140 F Maximum Humidity 95 non condensing EMC Environment Residential Commercial Light Industrial or Industrial Current Consumption Quiescent Current lt 25mA Alarm Current 150mA Auxiliary Voltage Output Regulated 13 5Vdc Switched Positive Voltage When Low 1 0Vdc When High 12Vdc Bell Voltage Output 12Vdc Speaker Voltage Output 12Vdc Strobe Voltage Output 12Vdc Internal Sounder 0 25Watts 32 Ohms Positive Loop Threshold Zones 1 7 PA Minimum Open Resistance 70kQ Maximum Closed Resistance 10kQ Negative Loop Threshold System Tamper Minimum Open Resistance 110kQ Maximum Closed Resistance 20kQ Dimensions 260mm X 225mm X 80mm Housing Material ST6100 ST6550 Inflammable 94VO High Impact ABS Plastic Housing Material ST6600 1mm Steel Weight ST6100 ST6550 1 70Kgs Weight ST6600 2 30Kgs Electrical Electrical Operating Voltage 12Vdc Operating Voltage 12Vdc Quiescent Current LCD Back Light Off 16 7mA Quiescent Current 2 LEDs Illuminated 15mA Current LCD Back Light On 90mA Current All LEDs Illuminated 55mA Current in Alarm 70mA Current in Alarm 35mA Wiring 6 Core Multi stranded Cable 7 x 0 20m Dimensions 135mm X 108mm X 80mm Housing Material ABS Plastic SL6600 Sleep Watch Re
5. BelNegaiveSuply _ E Keypad 8 Sleep Watch Keypad amp Sleep Watch INETWORKB Keypad amp Sleep Watch Datan INETWORKY _ Remote Keypad 8 Sleep Waton Data Out KEYPAD W Main Unit Battery Supply DataQut_ KEYPAD G Main Unit Mains Supply Data Out _ SABTRT istSefComsmedBelOuput SCB J SAB2RT 2ndSefConamedBelOuput SCE 1 10 PCB Terminals K6550 LED amp K6600 LCD Remote Keypad Terminal Description Remarks AUX Negative Supply From AUX 2 Remote Keypad amp Sleep Watch Data In 1222 e _ 7 NETWORKB Remote Keypad 8 Sleep Watch Data Out j 1 11 PCB Terminals SL6600 Sleep Watch Keypad AUX Negative Supply From AUX 2 Supply From AUX 2 NETWORK Y Sleep Watch Data In NETWORK B Sleep Watch Data Out 1 12 Fuses ST6100 ST6550 amp ST6600 Fuse Description Rating POWER Power Supply Output Fuse Fast Blow F1 6A 250V 20 X 5mm Auxiliary Fuse Fast Blow F1 6A 250V 20 X 5mm BATT Battery Fuse Fast Blow F1 6A 250V 20 X 5mm Installation 1 43 Bell Box Wiring ST6100 ST6550 amp ST6600 STANDARD a TAMP RT 5 5 BELL BELL STB STB ST6100 ST6550 ST6600 FLASHGUARD a SUPPLY gt 2 SI o TRIGGER 5 TAMP OUT 4 S SUPPLY 4 STROBE S mi STROBE TANP IN Sp n ST6100 ST6550 ST6600 NOVAGUARD IE 5 z 8 2 SAB 2 OV RT SAB 1 OV RT BELL
6. Exit File Fire Press and revert back to ENGINEER PROGRAMMING MODE Floor Foyer Freezer Fridge Front Door Gallery Garage 1 Garage 2 Gas Gate 1 Gate 2 Gymnasium Guestroom Hallway Hold Up House Internal Door Interior Kitchen Laundry Library Loading Area Lock Lounge Area Maids Room Master Bedroom Medical Mothers Room Nursery Office Engineer Programming Zone Name Outside Panic Patio Perimeter Police Pool Reception Roof Safe Shed Shop Skylight Sliding Door Smoke Detector Store Room Sons Room Studio Study Sun Room Tamper Utility Vault Ware House Wash Room West Room Window Work Shop Yard 2 14 Miscellaneous Section 1 In this section under programming key 5 you can enable or disable any of the following features Section Key No Description Zone LED Factory Setting 2 15 1 Quick Set 1 Disabled 2 16 Special Switch Positive zy Disabled 2 17 Exit Strobe Flashes Ec Disabled 2 19 Engineer Code Burn In 5 Disabled 2 20 6 Fnal Set Push Button SET ME Enabled 2 21 Day Mode LED illuminated Disabled 2 22 5 Entry Time Timed Out Alarm Disabled 2 23 9 Switch Positive 0 Volts Press or displayed upon LCD remote keypad Day Disabled if any features under this section have been enabled the corresponding LED is illuminated Note To enable or disable any of the above options toggle the corresponding key number After entering options under this sectio
7. Single Magnetic Door Contact ST6100 ST6550 amp ST6600 SAB2 TAMP Z1 System Tamper Three Magnetic Door Contacts Wired in Series ST6100 ST6550 amp ST6600 SAB 2 TAMP Z1 System Tamper Installation 1 17 Wiring 6550 LED amp K6600 LCD Remote Keypad ST6100 ST6550 amp ST6600 AUX2 Y B G W NETWORK Installation 1 19 Wiring Remote Key Switch O O OMIT MAINS ILe J e JLo J NVM RESET KEY SWITCH ea AUXI 5 STB BELL SPK AUX2 Y SAB 1 SAB 2 NETWORK OV RT 71 22 23 24 25 26 Z7IPA 26 e ee ejele ele ele eje elee od 0 Option 1 0 _ Option 2 Key Switch a Push Button HI System Tamper Option 1 Key Switch Wiring Option 2 Push Button Wiring Terminal Connection Wire Colour Terminal Connection Wire Colour L feom to me Note Use only a non latching momentary key switch with an LED or push button with this panel The yellow LED operates exactly as the day LED on the control panel and therefore tells you if the panel is armed or disarmed You can only wire either a key switch option number 1 or push button final set op tion number 2 which is the factory default setting If using option number 1 you must disable option 2 push button final set in engineer programming under section number 2 20 1 20 Commissioning the System Fit a fully charged 1 2Ah 7Ah 12Vdc sealed lead acid
8. Enter time using 2 digits to represent Hours Minutes After entering minutes it will revert back to engineer programming To check time Engineer entered you must enter this location again re enter time if wrong Programming 2 31 Exiting Engineer amp User Programming Press to exit engineer programming Tamper LED on Press to return to day mode Day LED Flashing 2 32 Reset Control Panel to Factory Default Settings NVM Reset To reset the NVM power down the panel and short out the NVM pins then power up and remove the short This will reset panel to factory set condition 2 33 Reset Control Panel without Losing Engineer Log From Engineer Programming mode Press This will reset the panel to factory set conditions but will not lose the engineers log 23 3 00 Engineer Reference Guide User Programming Tamper and Day LEDs On User Manual Page PROG All Zone and Day LEDs illuminated 1234 Tamper and Day LEDs Stay illuminated J Mer 2 JBelTet Enter HghSomderimemalKeypad Enter 4 Low Sounder internal Keypad 5 Wak Test PA and Tamper Give SameTone O extTestMode 2 To Set Second User Code Default 0000 T 3 ToSetThirdUsercode Default 000 T 12 12 Enter Enter 4 ToSetFothUserCole jDefaut 000 T 5 j ToSetFifthUserCode amp Defaut 0000 1 Press 9 To
9. RESET 16 5 _ MiscellaneousSectiont uum Enable Final Set Push Button Zone 6 LED On Enabled Toggle Key 6 Enable LED Day Mode PA LED On Enabled Toggle Key 7 24 Enable Engineer Code Zone 5 LED On Enabled Toggle Key 5 Ente 8 Entry Zone Full Alarm Tamp LED On Enabled Enter 9 Switched Positive 0 Volts DayLEDOn Enabled ToggleKey9 19 After Entering Options Press RESET Press 6 Zone Status Full Guard Enter Zone Number Press 20 Timed Exit Entry LED Indication Zonet Default Zonet _2 Wak Through Zone eet Zone nant LED Indication Zone3 Deraut Zone 3 6 mer Pecora mam PA LeDingeaon Zone pereur Zane PaT_ Enter 5 24Hour LED Indication Zone5 Default Zone Tamp __ pre ED indcation Zone 6 Detaut None 7 lente 7 FindSet LED Indication Zone PA Detam Noe Enter 8 DoubleKnock LED Indication Zone Tamp Default None Enter 9 Disable lsolate LED Indication Zone Omit Default None After Entering Option Press RESET Press 7 Change Zone Status Part Guard Enter Zone NumberPress 2 2 Ente 1 TimedExt Enry LED Indication Zone1 Default Zone 1 3 Enter 2 Through LED Indication Zone2 Default Zone2 Enter 3 Instant LED Indic
10. Set Chime Zones PA and Tamper LED illuminated Press RESET Press RESET Exit User Programming 13 Press MemoryRecallLastActivation Shown First 9 Programming Installation Manual Page Press PROG All Zone and Day LEDs illuminated 13 1234 Master User Code Tamper and Day LEDs Stay illuminated Default 1222 All Zone and Day LEDs illuminated as Press 9999 Engineer Programming Code and Day LEDs illuminated Default 9999 Press 4 Seconds 7777 305 14 Press 2 SetEntryTimeinSeconds 7 305 14 Press 3 Rest Time in Minutes 7 Detaut 15Minutes 14 Press 41 Set Part Guard Exit Time in Seconds 7 Default 5Seconds 15 Press 42 DisablellsolateZonesinPartGuard 15 Press 43 _ Set Sleep Watch Activation Zone Delay Time in Seconds Default 15 Seconds 15 Press 44 Enable Sleep Watch Zones Automatic Rearm Toggle Key 4 Press RESET 15 45 _ Set Sleep Watch Zones Automatic Rearm Time Default 15 Minutes 15 46 Enable Sleep Watch to Arm Disarm Part Guard Toggle Key 6 Press RESET 16 47 Enterinstaller Message Displayed Remote LCD Keypad Press RESET 16 48 _ Enter Zone Description Displayed on Remote LCD Keypad Press
11. Status A Press All zone LEDs and PA flashing Part Guard Zone 4 B Press Zone 3 LED illuminates indicating zone 4 present status Instant C Press Press Zone 1 LED illuminates Zone 4 Sleep Watch D Press Engineer Programming To Change additional zones repeat steps B C and D 2 27 Changing Engineering Code For security reasons it is best to use your own ENGINEER CODE rather than use the factory pre set code Press Zones 1 2 3 4 LEDs illuminated New Code ngineer Type in new engineer code After entering the forth digit the panel will give an acceptance tone and return to Engineer ENGINEER PROGRAMMING MODE the new code will now be operative Programming 21 Programming 2 28 Enable Service Timer To set service timer from engineer programming mode enter one of the following options Press Zone LEDs will show present status Zone LEDs not illuminated No service timer Service Timer Disabled Press Zone 1 LED illuminates 6 weeks timer Service Timer 6 Weeks Press Zone 2 LED illuminates 6 months timer Service Timer 6 Months Press Zone 3 1LED illuminates 12 months timer 12 5 months 1 Service Timer 12 Months Press an event 100 Events Service Timer Zone 5 LED illuminates 200 event timer 200 Events Press Zone 6 LED illuminates 800 event timer Service Timer 800 Events Press Press Zone 4 LED illuminates 100 event timer arming an
12. Contents CONTENTS Section Page No 1 00 Conirol Panel Installation 2 1 01 Introduction to Control Panel 2 1 02 Pre installation Testing 2 1 03 Mounting Control Panel 2 1 04 Wiring and Safety Information 3 1 05 ST6100 Printed Circuit Board Wiring Terminals 4 1 06 ST6550 amp ST6600 Printed Circuit Board Wiring Terminals 4 1 07 K6550 LED amp K6600 LCD Remote Keypad Printed Circuit Board Wiring Terminals 4 1 08 SL6600 Sleep Watch Keypad Printed Circuit Board Wiring Terminals 4 1 09 ST6100 ST6550 amp ST6600 Control Panel Wiring Terminal Description 5 1 10 K6550 LED amp K6600 LCD Remote Keypad Wiring Terminal Description 5 1 11 SL6600 Sleep Watch Keypad Wiring Terminal Description 5 1 12 ST6100 ST6550 ST6600 Fuse Specifications 5 1 13 Wiring External Bell Boxes 6 1 14 Wiring Passive Infrared Detectors 7 1 15 Wiring System Tamper 8 1 16 Wiring Magnetic Contacts 8 1 17 Wiring K6550 LED amp K6600 LCD Remote Keypad 9 1 18 Wiring SL6600 Sleep Watch Remote Keypad 9 1 19 Wiring Remote Key Switch 10 1 20 Commissioning the System 10 1 21 Trouble Shooting 11 2 00 Engineer Installation Programming Section 13 2 00 Control Panel Factory Default Settings 13 2 01 Day Mode 14 2 02 Engineer Installation Programming 14 2 03 Exit Time Adjustment 14 2 04 Entry Time Adjustment 14 2 05 Siren Duration Time Adjustment 14 2 06 Part Guard Exit Time Adjustment 15 2 07 Disable Isolate Zones in Part Guard 15 2 08 Sleep Watch Delay Time Adjustment 15 2 09 Ena
13. Enabled Engineer Press and revert back to ENGINEER PROGRAMMING MODE pia rai mind 2 12 Set Installer Message Enter the following options to display installer message on the K6600 remote LCD keypad when in normal operation mode Press Message 16 characters can be programmed as the installer message Enter the 2 digits to represent the character required to be displayed on the LCD keypad To move the curser use the MEM key to move left and the OMIT key to move right Engineer Press When message is complete Pron aris Valid Entries o O o N lt c 7 IQmnmuoou2mdocor o lt lt K L 0 P Q R 26 T U V W X 2 13 Remote K6600 LCD Keypad Zone Location Display Names Each zone can be given a location name from the list below The location name will be displayed upon the K6600 remote LCD keypad display if that zone is activated or has a fault upon arming the system Press Enter zone number Zone Name Enter corresponding zone name number from list below Example Zone 1 as Front Door enter 35 Zone 1 Press Zone 1 Enter Front Door 16 Programming Press Alarm Apartment Auxiliary Babies Room Back Door Back Yard Barn Basement Bathroom Bedroom 1 Bedroom 2 Bedroom 3 Bedroom 4 Boys Room Building Ceiling Coatroom Computer Room Daughters Room Desk Dining Room Dock Downstairs Driveway East Room Studio Emergency Entry amp
14. LATE K6600 LCD REMOTE KEYPAD 1 04 Wiring and Safety Instructions WARNING ELECTRICITY CAN KILL Ensure electricity is switched off at the mains before installing and fitting the mains supply Alarm Cable Entry Point Screw Mounting Hole Alarm Cable Entry Point Screw Mounting Hole Battery Connectors 4 Plug Pack Cable Mains Cable Entry Point Battery Connectors Alarm Cable y Alarm Cable Entry Entry Point Entry Knockout Earth Wire Terminal Knockout Earth Wire Terminal 220 240VAC Mains Ag Supply Cable Connection Mains Terminal Plug Pack Red or Brown to L Live Terminal Connection Green Yellow or Green E Earth LION Blue or Black to N Neutral DANGER LIVE ST6100 ST6550 amp ST6600 LOW VOLTAGE ST6100 ST6550 ST6600 220V 240VAC TRANSFORMER WIRING 18 0V AC PLUGPACK WIRING 1 The control panel must be wired according to Current National Wiring Regulations if fitted with an internal transformer 2 Areadily accessible device for disconnecting from the mains e g 3 amp un switched fused spur must be provided as part of the installation If the control panel is wired to a 13 amp wall socket a 3 amp 250V fuse must be used Use mains 2 core cable and earth cable capable of carrying the rated current i e at least 1mm The control panel must be wired to earth 5 Wiring of the mains supply to the transformer terminal block in the control panel should pass through the smaller aperture in the rear
15. ar RT S C S y Clear TM Disabled isolated Zones Clear S Cd Sleep Watch Zones Delay Activation Time 15Seconds Sleep Watch Zones Automatic Rearm Disabed Cd Sleep Watch Zones Automatic Rearm Time IM5Mintes Sleep Watch Keypad Arm Disarm Part Guard Disabled Po Melcom ERES y S C O y E M Disabled Disabled Engineer Code Burn In Disabled Final Set Push Button Enabled LED Day Mode Illuminated Enabled Entry Timed Out Full Alarm Disabled Switched Positive O Volts Day amp Armed Mode Disabled Clear Part Guard Set Time 5 Seconds Zones Disabled Isolated None Timed Entry Exit Walk Through Timed Entry Exit Zone 4 Zone 5 Zone 6 Zone 7 PA Personal Alarm P A 26 Sleep Watch Zones Location Zosi lear 12 Zone 2 Clear ZoneS Zones Zones ear S j Zone 7 PA Clear 3 02 Customer Information Installation Engineer Installation Compan Address Telephone Number Date of Installation Maintenance amp Call Date Time Reason For Visit Name of Engineer Note These instructions MUST NOT be stored inside the control panel The User instructions contain ESSENTIAL SAFETY INFORMATION amp MUST be given to the user 27 4 00 Electrical and Technical Specifications Power Supply Primary Mains Supply Voltage Rating 230Vac 115Vac 10 Secondary Input Voltage Rating
16. ast two key holders of the property protected 2 Instruct the key holders in the operation and silencing of the alarm 3 Within 48 hours of installation inform the local Environmental Health Authority of the installation and which local police station you have notified 4 Inform the local police of any changes of the key holders within 24 hours of the change 1 21 Trouble Shooting Always disconnect unit mains supply BEFORE removing the front cover No Mains Power to the Control Panel Mains Red LED e Check the AC fuse on the PCB if blown replace with 1 6Amp 250V fast blow fuse e Check for loose wiring into the mains terminal block e Check for loose wiring from mains supply e Check AC connector is connected correctly to the control panel PCB No Battery Power to the Control Panel Mains Orange LED Flashing e Check the Battery fuse on the PCB if blown replace with 1 6Amp 250V fast blow fuse e Check Battery wires are connected correctly to the battery Red Black Note If No Mains Power Supply and Low Battery this is Indicated by Mains Red LED Flashing Unit Does Not Accept Code Upon Power Up e f remote 516600 K6550 LED or K6600 LCD keypads are connected ensure each keypad has a different address Check wiring of remote keypads Disconnect power momentarily so that the system can configure all keypads connected to system Reset NVM to factory default settings Unit Will Not Set and Tamper LED on e Check system
17. ation Zone3 Default Zone 4 5 6 Ere sewer iso sean znes owns After Entering Option Press RESET Set New Engineer Programming Code Defaut 999 21 Ps NG ESR Enter Timer LED Enter 2 Weeks Service Timer_ LED Indication Zone1 Enter 3 6 Service Timer LED Indication Zone2 Ente 4 12 Months Service Timer LED Indication Zone3 2 Ente 5 100Events LED Indication Zonea Enter 6 200Events LED Indication ZoneS Ente 7 800Events LED Indicaton Zone6 j E After Entering Option Press RESET Press 98 SetDate Displayed on LCD Keypad Only Set Time Displayed on LCD Keypad Onl Reset Panel To Factory Default Setting Without Losing Engineer Log xitEngineer Programming Press _ RESET Returns to User Programming CdS ER Exit User Programming i i Press RESET ReturnstoDayMode 0000 ResetPanetoFactoyDefautSetings 23 Short NVM Reset Pins Disconnect Power Return Power To The Unit and Remove Short From NVM Reset Pins 25 3 01 Engineer Programming Record Function Factory Settings Installation Settings 30 Seconds 30 Seconds 15 Minutes Full Guard Zone 2 Zone 3 Instant Zoneb Instant Instant Personal Alarm P A Tamper Zone 5 Zone 6 Zone 7 Zones Tampr E Final Set Zones Cle
18. ble Sleep Watch Automatic Rearm 15 2 10 Sleep Watch Automatic Rearm Time Adjustment 15 2 11 Enable Sleep Watch Arm and Disarm Part Guard 16 2 12 Display Engineer Message on K6600 Remote LCD Keypad 16 2 13 Display Zone Location Names on K6600 Remote LCD Keypad 16 2 14 Miscellaneous Section 1 17 2 15 Enable Quick Set 18 2 16 Enable Special Switched Positive 18 2 17 Enable Exit Strobe Flashes 18 2 18 Enable Engineer Reset 18 2 19 Enable Engineer Burn In Code 18 2 20 Enable Push Button Final Set 18 2 21 Enable Day LED Illuminated Day Mode 19 2 22 Enable Entry Timed Out Full Alarm 19 2 23 Enable Switched Positive O Volts 19 2 24 Zone Type Description 19 2 25 Changing Full Guard Zone Type 20 2 26 Changing Part Guard Zone Type 21 2 27 Change Engineer Programming Code 21 2 28 Set Service Timer 22 2 29 Set System Date 22 2 30 Set System Time 22 2 31 Exit Engineer Installation Programming 23 2 32 Reset Control Panel to Factory Default Settings 23 2 33 Reset Control Panel without Losing Engineer Log 23 3 00 Engineer Reference Guide 24 3 01 Engineer Programming Record 26 4 00 Control Panel Technical Specifications 28 1 Installation 1 00 Control Panel Installation 1 04 Introduction to the Control Panel The control panel has been designed for both installer and user friendliness The factory default settings have been carefully selected to suit most installation needs However most functions are fully programmable for flexibility when installin
19. casing of the panel NEVER connect the mains supply directly to the PCB The unit requires wiring to a suitable earth refer to National Wiring Regulations It is recommended that the unit is wired by a qualified electrician Check for hidden cables and or pipes before drilling 8 Use safety goggles when drilling or hammering in cable clips 3 Po Installation 1 05 ST6100 Printed Circuit Board PCB SPEAKER O O OMIT MAINS 29 NVM RESET KEY SWITCH SAB 2 E 9 gt AUd S STB BELL SPK AUX2 B Y G W SAB 1 q s 2 9 2 NETWORK OV RT OVRT TAMP 21 22 23 24 275 26 Z7 PA SPEAKER O 1 MICROPROCESSOR KEY SWITCH 69 olo ola oja 2 0 20 oje e e 20 2 0 e E g AUXI S STB BELL SPK AUX2 B Y SAB1 SAB2 9 2 4 T NETWORK OV RT OVRT TAMP 71 22 23 24 25 1 07 K6550 amp K6600 Printed Circuit Board PCB 1 08 SL6600 Printed Circuit Board RED BLK m m o am 5s Bo ez o oz m z 5 Installation 1 PCB Terminals ST6100 ST6550 amp ST6600 09 Terminal Description Remarks E Earth Connect to Ground N C Normally Closed Relay Contact Rated at 0 5A 12Vdc COM O Regulated Auxiliary Supply Negative 578 Latching Strobe Positive Supply STB Latching Strobe Negative Supply BELL Bel PositveSupply SSS S y O
20. ch Keypad Does Not Work e Ensure zones are programmed as Sleep Watch zones e Ensure each Sleep Watch Keypad has a different address to Remote Keypads or other Sleep Watch Keypads e Check wiring to control panel and Sleep Watch Keypad e Check Power Fuse on Main Unit PCB if blown replace with 1 6Amp 250V fast blow fuse 12 Programming 2 00 Engineer Installation Programming Section 2 00 Control Panel Factory Default Settings The control panel is pre set to the following settings Most of these settings can be changed in the customer programming mode and engineering programming mode 30 Seconds 30 Seconds 15 Minutes Entry time Exit Time Part Guard Set Time 5 Seconds 15 Seconds 15 Minutes Sleep Watch Zone Delay Activation Time Sleep Watch Zone Automatic Rearm Time gt 2 3 d 3 Full Guard Part Guard Zone 1 Timed Entry Exit Timed Entry Exit Zone 2 Walk Through Zone 3 Timed Entry Exit Zone 4 Instant Zone 5 Instant Zone 6 Instant Personal Alarm Clear Clear Enabled Clear NIN olo 2 2 olo a gt 3 Date amp Time Day LED On Disabled Isolated Zones Clear 9999 Disabled Disabled Disabled Disabled Disabled Clear 1234 Enabled Disabled Clear Double Knock Zones Engineer Code Engineer Code Burn In Engineer Service Timer Engineer Reset Entry Time Timed Out Alarm Final Set Fire Zones Master User Code Push Button Final Set Clear Disabled Disabled N
21. d disarming is Service Timer 6 After entering required service timer Engineer Programming Press Once the pre set service time has timed out the Tamper LED will flash and continue until the engineer programming code has been entered If the service timer is required again then the service timer must be reprogrammed The control panel will continue to function once the service timer has timed out Note Entering engineer programming will not reset the service timer once set unless service timer has time out 2 29 Setting System Date The date will only be displayed if the system is fitted with a K6600 remote LCD keypad In the event of an alarm activation the date is stored in the memory log Set Date Press 9 00 00 00 Enter date using 2 digits to represent Year Month and Day The year should be entered first followed by month and day date will be displayed on LCD DD MM YY After entering Day it will revert back to engineer programming To check date Engineer entered enter this location again re enter date if wrong Programming Note Inthe event of complete power failure the Date amp Time must be RESET 22 Programming 2 30 Setting System Time The time will only be displayed if the system is fitted with a K6600 remote LCD keypad In the event of an alarm activation the time is stored in the memory log The time is displayed in 24 hour format Set Time Press 9 00 00
22. e 6 LED illuminated Final Set Push Button enabled F S Push Button Enabled 2 221 Enable Day LED After enabling this option the system Day LED will stay illuminated in Day Mode when system is disarmed Press PA LED illuminated Day LED stays illuminated enabled Day LED On y y Enabled 2 22 Entry Time Full Alarm After enabling this option the system will go into full alarm if the entry time times out before a valid user code is entered Entry Alarm Press Tamper LED stays illuminated Entry Time Full Alarm enabled Enabled 2 23 Switched Positive 0 Volts After enabling this option the Switched Positive will act in the following way In armed mode and day mode O Volts any alarm activation 12 Volts Enable this feature if using a melcom AD1000 voice auto dialer Switched Pos 0V Press Day LED Flashing Switched Positive 0 Volts enabled Enabled Note Special Switched Positive amp Normal Switched Positive will not work if this location is programmed If you have enabled any of these options Quick Set Day LED or Entry Time Full Alarm the system will not comply with current European alarm installation regulations After entering options under section 5 press RESET key to exit this location 2 24 Zone Description Exit With the panel in DAY mode if a valid user code is entered the control panel will go into it s armed sequence If any zone is at fault the control panel will stop it s count down until t
23. f a Entry Exit zone is programmed as final set upon arming the system and leaving by the Entry Exit route the system will arm immediately once the Entry Exit zone is clear without waiting for the exit timer to time out Double Knock When a zone is programmed as a Double Knock zone it requires two activations within 30 seconds before creating an alarm condition when panel is set Disabled Isolated When a zone is programmed has a Disabled Isolated zone it is ignored in the event of any activation It al lows the user to continue using the alarm system even if a fault has been discovered on one or more zones 2 25 Changing Full Guard Zone Type All zones can be changed to any status listed below Key No Function Zone LED Factory Default Timed Entry Exit Zone 1 2 Walk Through Zone 2 3 Instant Zone 3 4 5 6 4 Personal Alarm PA Zone 7 PA 1 5 Fire Clear 7 Final Set A Clear FS Double Knock Tamper Clear E 201 S 3 _ E EE i 24 Hour Tamper Zone 8 Tamper Zone Disable Isolated Omit Clear Changing a zone status Press All zone LEDs PA flashing Enter zone number to be changed the zone present status will be indicated by zone LEDs Press Enter required key function number the corresponding key number is shown by zone LED Press Press to return back to engineer programming Example Programming zone 5 as Entry Exit zone Zone Status A Press All zone LED s and PA flas
24. g the system All changes made are stored within a Non Volatile Memory NVM and are retained even when there is complete loss of power Please read these instructions carefully before attempting to install this control panel Ensure the user instructions are given to the user after installation 1 00 Pre testing the Control Panel before Installing 1 Unscrew the two screws from the front cover 2 Remove the cover and put in a safe place with the screws If connecting a K6550 LED or K6600 LCD remote keypad follow instructions as described within the keypad 3 Connect a fully charged 12V 1 2 7 0Ah sealed lead acid battery black lead wire to the negative of the battery terminal and the red lead wire to the positive of the battery terminal 4 The control panel day LED will flash and also the mains LED will illuminate red indicating running from battery power The tamper LED will illuminate indicating a tamper fault Hold down the tamper spring and fix under the on broad keypad ST6100 only the tamper LED will extinguish Note If mains Red LED is flashing this indicates low battery Change the battery before proceeding with testing the control panel 5 Press Zone LEDs illuminated 6 Enter User Programming 7 Press Co Walk test PA amp Tamper give the same tone 8 Remove and replace each zone link the corresponding zone LED will illuminate and also beep indicating which zone is activated After testing all the zo
25. hat zone is cleared or omit ted from the system then will carry on arming the system Entry When the panel is set and the entry zone is triggered the entry timer will begin its countdown During this period the remote keypad will give a repeated beep and will beep faster when nearly timed out If the time is allowed to elapse before any valid user code is entered the control panel will go into alarm state In this case the system needs to be Reset by pressing the RESET key after a valid user code has been entered to disarm the system Walk Through This zone allows access without the alarm activating provided that the exit entry zone as been activated before this zone Instant This zone will create an alarm condition immediately if the control panel is set 24 Hour Tamper A Tamper zone activation will only generate an internal alarm if the panel is in DAY mode Triggering of the tamper zone when the panel is set will always give an external as well as internal alarm Personal Alarm PA Triggering of the personal attack P A zone will always cause a full alarm regardless of whether or not the panel is set Programming Fire Zone Triggering of the fire zone will operate internal amp external sounders giving an intermittent sound which is easily distinguished from the normal alarm sound Note Fire zones are intended as an extra feature to the alarm system and must not be regarded as a total fire protection system Final Set I
26. hes When this function is enabled upon setting the system in full guard the strobe will give 5 flashes indicating Press zone 3 LED illuminated Strobe Exit Flashes enabled 2 18 Enable Engineer Reset When this function is enabled it prevents the user from resetting the system in the event of a Full alarm PA or Tamper alarm activation System can only be reset after entering the engineer code and pressing reset after the alarm has been silenced by entering a valid user code Engineer Reset Press zone 4 LED illuminated Engineer Reset enabled Enabled 2 19 Enable Engineer Code Burn In When this function is enabled the engineer code will be retained in the memory and can not be changed even if the control panel is reset to factory default setting In the event you forget your code PCB must be returned to supplier for repair Code Burn In Press zone 5 LED illuminated Engineer Code Burn In enabled Enabled 2 20 Enable Final Set Push Button The Final Set push button is used to Final Set the system after you have entered a code to arm the system by pressing the button during exit time it will stop the exit timer and immediately arm the system The button should be installed on the outside of the protected area During Day Mode and Part Guard it will act has a door bell giving a chime sound when pressed You can not use a key switch to arm and disarm system if Final Set push button enabled Programming Press zon
27. hing Full Guard Zone 5 Instant C Press Press Zone 1 LED illuminates Zone 5 Entry Exit D Press Engineer Programming B Press Zone 3 LED illuminates indicating zone 5 present status To Change additional zones repeat steps B C and D 20 Programming 2 26 Changing Part Guard Zone Type All Part Guard zones can be changed to any status listed below Key No Function Zone LED Factory Default Timed Entry Exit Zone 1 amp 3 1 1 Note If a zone is programmed as PA 24hr Fire or disabled in full guard it is not possible to change the status in part guard Sleep Watch Zone Sleep watch zones are like interior zones and can be armed and disarmed using the SL6600 sleep watch keypad Sleep Watch zones are armed in part guard after the system is set and by pressing the sleep Watch button for 1 second Upon a sleep watch zone being activated it will not instantly go into full alarm but start a delayed activation time has programmed This gives the user time to disarm the system if a sleep watch zone is activated accidentally by enter their code into the keypad Changing a zone status Press All zone LEDs and PA flashing Enter zone number to be changed the zone present status will be indicated by zone LED Press Enter required key function number the corresponding key number is shown by zone LED Press Press to return back to engineer programming Example Programming zone 4 as sleep watch zone Zone
28. ime is the maximum period of time between setting the alarm and leaving the property via the EXIT route Press Zones 1 2 3 LEDs illuminate Exit Time 030 Input a new Exit time max 255 seconds Eg for 70 seconds input 070 for 95 seconds input 095 etc When the third digit is input the panel will give an accep Engineer tance tone and will revert back to ENGINEER PROGRAMMING MODE Programming 2 04 Entry Time Adjustment This is pre set at 30 seconds Entry time is the maximum period of time between activation opening of front door of ENTRY EXIT route and the alarm sounding It will allow time to enter the property and switch off the system Press Zones 1 2 3 LEDs illuminate 030 Input a new Entry time max 255 seconds Eg for 45 seconds input 045 for 15 seconds input 015 etc When the third digit is input the panel will give an acceptance Engineer tone and will revert back to ENGINEER PROGRAMMING MODE Programming Note To comply with EN50301 1 entry time should not exceed 45 seconds also internal siren activates if user code not entered before timing out full alarm 30 seconds later 2 05 Siren Duration Time Adjustment The Siren Duration time is pre set to sound for 15 minutes when activated Do not set the alarm for a longer period than that specified by legislation You can adjust the siren to sound for less than 15 minutes Press Zones 1 2 3 LEDs illuminate Siren Time 015 Input a new Siren time max 255 minutes
29. mote Keypad Electrical Operating Voltage 12Vdc Quiescent Current 16 7mV Wiring 4 Core Multi stranded Cable 7 x 0 20m Dimensions 135mm X 108mm X 80mm Housing Material ABS Plastic Weight 0 20Kgs 28
30. n press RESET to save changes and exit this location 17 Programming 2 15 Enable Quick Set After enabling this option the system maybe armed by pressing the set key for 3 seconds this will begin the full set arming sequence without entering a user code Press zone 1 LED Flashing Quick Set enabled Quick Set Enabled Note If this function is enabled the installation will not comply with EN50130 1 requirements 2 16 Enable Special Switched Positive The programmable Switched Positive is a unique feature of this control panel In the factory default the Switched Positive behaves in a normal manner going high when the panel sets and low when the panel is switched off for latching passive infra red detectors In the Special Switched Positive this output can be used for impact sensors which require the power to be removed to reset them This output will give out up to 200mA as a positive supply to these detectors which will behave in the manner described below When enabled the Special Switched Positive will be high but when the panel is switched on Switched Posi tive goes low for 5 seconds to reset the sensors In the case of activation even if the panel is reset the power will remain on the impact sensors until the panel is switched back on again This enables the informa tion from the impact sensors to be retained Press zone 2 LED illuminated Special Switched Positive enabled adios Pos 2 17 Enable Exit Strobe Flas
31. nes and tamper release tamper switch spring System Read 9 Press twice disconnect and remove the battery y Melcom These simple tests will demonstrate that the control panel and remote keypad if fitted are working correctly Disconnect the battery from the control panel in preparation for wiring 1 03 Mounting the Control Panel The main control panel unit should be positioned out of reach of children in a secure place close to a mains electricity supply The unit should not be fitted to a flammable or uneven surface 1 Remove the PCB by disconnecting the AC supply cable from the transformer and also from the speaker connector put the PCB in a safe place 2 Using the rear panel as a template mark the positions of the mounting holes The mounting surface must be solid Do not fit to a flammable or uneven surface Drill mounting holes and fit wall plugs 3 Thread the mains supply AC power cable through the smaller aperture in the rear casing At this stage do not connect the AC supply cable to the panel 4 Attach rear panel to wall using at least three 30mm No 8 wood screws 5 Replace the PCB and reconnect the AC and speaker connectors Installation AC Power Cable Back Cable Entry Knock ockouts Front LCD 240V AC Mains Display Cable Entry or Plug Pack Cables 240V AC Mains Cable Terminal Block Front Cover Release Pegs Tamper Spring ST6100 ST6550 AND BACK P
32. ormal Disabled Switched Positive User Codes 2 3 4 5 6 PME RE _ 000 5 pss Double Knock Zones Engineer Code eos S Engineer Code Burnin Disabled 0 Engineer Service Timer Engineer Reset Disabled ooo Entry Time Timed Out Alam Disabled ______ Fna Set Fre Zones 0 0 Master User Code Push Button Final Set Enabled Quick Set Disabled ooo Secure Zones 00 0 Sleep Waton Zones oea ooo Sleep Watch Keypad Disarm Part Guard Disabled Strobe Exit Flashes Disabled Switched Positive fuser Codes 2 3456 Programming 2 01 Day Mode This is the normal default setting of the control panel The alarm will only activate if the PA Fire Zones or Keypad PA are activated 2 02 Engineer Installation Programming To enter the engineer programming mode K6600 Keypad Displ Press All red LED s illuminated Enter Zone LEDs extinguished User TAMPER and DAY LEDs stay illuminated Programming Press All red LEDs illuminated Enter JLo J J Zone LEDs extinguished Engineer PA and DAY LEDs stay illuminated Programming You are now in Engineer Programming Parameters can be adjusted as described in sections 2 03 to 2 30 Note For user programming functions refer to engineer quick reference guide or user manual 2 03 Exit Time Adjustment This is pre set at 30 seconds Exit t
33. rechargeable battery to the connectors inside the control panel After fitting the battery the Tamper and mains LED will illuminate Day LED will flash for a few seconds Replace the front cover of the main unit tamper LED goes off Switch on the mains power mains LED will illuminate orange on the main control panel and Green on the K6550 LED amp K6600 LCD remote keypad Go to USER manual page No 14 testing system and follow the instructions IMPORTANT There are no user serviceable parts contained within the control panel and keypads DO NOT attempt to interfere with or alter any of the electronic components To do so may damage the electronic circuitry and will invalidate your warranty The Melcom alarm system can provide valuable protection for your home and property if used properly However the system can not guarantee complete protection against burglary or robbery Therefore the manu facturer distributor or supplier will not be held responsible for any loss or damage that may occur Every effort has been made to provide accurate information however slight variations can occur We also reserve the right to make changes for product improvement at anytime 10 Installation We recommend that you check your local by laws relating to Intruder Alarm Systems In certain countries you are required by law to 1 Notify the local police in writing within 24 hours of the alarm being installed the names and address of at le
34. tamper replace link into tamper zone and replace lid to see if this clears the fault e Check system tamper wiring e Check tamper wiring to detector and sensors Unit Will Not Set Zone and LED Flashing e Ensure the zone is closed No movement in that area windows and doors are closed e Check wiring to that zone replace link and see if system sets e Check wiring to detector and sensors e l fyou have a meter check the resistance to that zone Day LED Flashing e Enter USER code to set system note which zone is in fault Ensure the zone is closed No movement in that area windows and doors are closed Check wiring to that zone replace link and see if system sets Check wiring to detector and sensors If you have a meter check the resistance to that zone Unit Makes No Sound e Ensure that the internal speaker is connected to PCB Remote Keypad Does Not Indicate Power e Ensure you are using 6 core wire and that they are wired correctly to keypad and main unit e Check Power Fuse on Main Unit PCB if blown replace with 1 6Amp 250V fast blow fuse 11 Installation External Bell Box Does Not Work e Check wiring connections bell boxes on page 6 e f not using both SAB s 1 amp 2 terminals ensure link is still connected to SAB terminal not used Panic Button Does Not Work e Ensure zone type is programmed as PA e Check wiring to control panel and panic button e Check panic button has been reset using the reset key Sleep Wat