Contents

1. 31 TR 51A 52 Basic Functions Set the Recording Conditions 32 Downloading Recorded Data 35 Detailed Settings 36 TR 51S 52S Basic Functions Set the Recording Conditions 37 Making Warning Settings 39 Downloading Recorded Data 40 Other Functions Checking for Warning Occurrences 41 from the Warning Times Button 41 Removing a Warning Mark from the Data Logger Display 42 Software Settings 43 Adjustment Settings 44 Graph Temperature Humidity Graph Display Names and Functions 45 When opening data recorded in TR 73U units into a graph 47 Zooming In and Out on the Graph 48 Data List Display 49 Graph Maintenance Changing graph display colors 50 Selected Channels ON OFF 50 Set High Low Average Calculation Range 51 Edit Recording Conditions 52 Re order Channel Data 53 Erase Selected Channel Data 54 Shift Unit C F 54 Change Graph Colors 55 Copy Display to Clipboard 55
2. Even after uninstalling saved data files will still remain in the folders and locations they were saved in Also saved Remote Unit registration info may still remain If you wish to delete all of these data and registration files make sure to delete all of the relevant folders after uninstalling but before reinstalling 61 Other Troubleshooting Q The computer won t communicate via the Serial Port What should do A Try two or three times to find the port connection by using the Auto detect function A Check to make sure that the power of the main unit is ON A Check to make sure that the connection is proper Communication will take place only through the serial port RS 232C and will not work through the printer port or any other port A Check to make sure that you can control the Thermo Recorder via the software A If you have access to another computer try seeing if communication works with the other computer A lf you have a computer with energy saving function settings make sure that the serial port has not been turned off Especially on NEC brand PC98 notebook computers the default setting maybe such A Check to make sure that the serial port has not been rendered unusable by the BIOS setting A Make sure that the serial port setting has not been made to render the port unusable With some computers especially all in one computers the serial port serves as the modem jack How to check
3. Basic Function TR 51S 52S 42 Software Settings from the Setting Menu Upon Connecting a Thermo Recorder open the Software Program This setting opens the software program upon the connection of a TR 51S 52S unit via USB cable If the setting is ON the Quick Start Program will periodically communicate with the device driver and upon the detection of a USB connection will open the main software program For more details about Quick Start and how to quit it see P 9 1 Place a check next to Upon Connecting a Thermo Recorder open the Software Program Setting Menu With no checkmark Quick Start will be disabled Quick Start will be enabled With a checkmark 2 Click OK to complete the setting Temp Unit to be displayed in Software Program Select whether to use Celsius or Fahrenheit as the displayed unit of temperature when monitoring current readings and using the adjustment function 1 Check either unit of temperature Celsius or Fahrenheit pliner commer i Themi er te oes L OK Cae Button Check here 2 Click OK to complete the setting 3 After completing settings please close the TR 51S 52S program and reopen it to make settings effective 43 Basic Function TR 51S 52S Adjustment Settings from the Communication Menu Here it is possible to record data after applying an adjustment formula to the measurement 1 Set the Data Logger so that communication can
4. Bosak i a tal Check one bij ii h ae od After downloading automatically show graph After data has been downloaded it will automatically be displayed in the Temp Humidity graph Window The File is not saved and if necessary should be done separately After downloading specify file in which to save data After data has been downloaded the Save File dialog box will appear wherein you can save the data to a specified file After downloading specify file name and automatically show graph The data is saved to the specified file and the graph for that file is automatically opened in the Temp Humidity Graph Window Download Settings Display for TR 50U When downloading data via a TR 50U the layout for the Settings display will be as below The downloading procedure is the same When using a TR 50U it is possible to specify which data to download by time Basic Function TR 51A 52 36 TR 51S 52S Basic Functions Here all settings and communication for TR 51S 52S Data Loggers can be carried out Connect the Data Logger to the Computer so communication can be carried out Please make sure that your computer clock settings are correct For details about connecting the data logger see p 13 Before Using In order to make optimum use of the TR 51S 52S Data Logger s features we strongly suggest using in conjunction with TR 50U This section explains operations when using with Communication P
5. Place the Data Logger face down A Ca Communication cable that was connected to your computer See pp 11 12 13 Getting Ready When using TR 71U 72U 73U Connect the TR 71U 72U 73U unit to your computer with the USB Communication Cable US 15C 1 If necessary serial communication can be established by using our TR 73U communication protocol contact your local dealer to write a software program In this case it will necessary to connect to your computer using our optional serial communication cable TR 07C Please contact your local provider for more details USB Port Mark The USB cable is a USB A Plug USB mini B plug type Please connect to a place with this kind of mark USB mini B plug still putes TD To the data logger It is necessary to install a USB device driver Please see the Hardware User s Manual for details about installation NOTE To ensure proper communication make sure that the USB cable connection is secure This software is designed to operate TR 71U 72U 73U units with USB connections and cannot operate the units via serial communication cables If you wish to use serial cables to communicate with TR 71U 72U units please install Thermo Recorder for Windows 4 11 E from the CD ROM menu and treat the units as TR 71S 72S units Note that communication with TR 73U via serial cable is not supported by the software For more details about the use of T
6. T amp D Recorder for Windows TR 5 7xU E User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit Copyright 2002 2007 T amp D Corporation All rights reserved 2007 09 16004264190 Notices about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Microsoft and Windows and Excel are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company Lotus is a registered trademark of the Lotus Development Corporation Specifications design and other contents outlined in this manual are subject to change without notice On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mis
7. 1 View in the Device Manager Window For Windows XP or 2000 1 On the Desktop right click on My Computer and click on Properties 2 In the System Properties Window click on the Hardware Tab then click on the Device Manager button to view the Device Manager Window For Windows 98SE or ME 1 Open the Control Panel and double click on System to display the System Properties 2 Click the Device Manager Tab to view the Device Manager Window 2 Inthe Device Manager click on Port COM amp LPT and check to see if under that appears Com Port COM1 or Com Port COM2 Other 62 63 If a port appears it should be usable Ifamark Jor X appears next to the port this communication port is unusable If you cannot use a communication port please contact your computer company To find out more details about an unusable communication port Select the port with a mark and then click on Properties to view the details about that port A If your computer has an internal modem make sure that the communication port is not being used by it When the communication port is being used as the modem port that port cannot be used Either quit using the modem or use another port EEEL terete Correceen fo art Dn Mt m gt An example of the modem using a communication port COM 1 PePe gn If your computer has no serial port use a Serial USB conversion cable and carry out commu
8. 5 10 15 20 30 seconds or 1 2 5 10 15 20 30 minutes Default setting is 10 min Recording Mode One time Upon reaching capacity of 16000 readings FULL will appear on the LCD display and recording will automatically stop Endless Upon reaching capacity of 16000 readings the oldest data is overwritten and recording continues NOTE The start date and time for a programmed recording start is based upon your computer system clock If your computer clock is not set correctly a programmed recording start may not start properly The estimated finish date and time of recording in one time mode will be automatically calculated from the set recording interval and starting time Recording Start Button After making the necessary recording condition settings click the Recording Start button and the settings will be transmitted to the Data Logger If you have selected a programmed recording start the unit will be put into recording wait status If you have selected immediate start recording will begin Get Settings Button Reads the settings from the connected Logger NOTE When using Communication Port TR 50C it is not possible to use the Get Settings function Stop Recording Button Recording will stop Warning Settings Button Opens the Warning Settings window wherein settings for Upper and Lower Limits and Judgment Time can be made Basic Function TR 51S 52S 38 Making Warning Settings from
9. Detect 1 Click the Auto Detect button and searching will begin 2 After the search has finished a Search Results message will appear By clicking the Set button the setting will be finalized as the port to which the data logger is connected NOTE If Auto detection does not work properly please see Troubleshooting for advice Select Serial Port 1 Open the Settings and Communication window for the data logger you are using and click on the Communication Port Settings Tab 2 Check the COM Port you wish to use for T amp D Recorder for Windows in the Possible COM Ports list 3 By clicking the OK button the setting will be finalized oe Gomm ho Demrload Recete Data Stat Receding Commrrcaten Pot Seting aw asoma Auto Detect Cem O ora ator Mathes Button Commarecete na RS ZUI check Com Ports for which communication is possible Check here when using Communication Port above COM9 NOTE When using TR 50U to make recording settings or download data first open TR 5S and then carry out the desired settings and or communication If you are using a Data Collecting Device which has a USB interface other than TR 50U please place a check next to Communicate via USB as shown in the above screen Getting Ready 16 17 Getting Ready TR 71U 72U 73U Basic Functions Display Names and Functions Menu Bar ns m Toolbar 94 59 CA T E Device List Device Pr
10. Display Format Settings from the Date Display Menu The date format chosen will be applicable for all sections of the software including graphs and setting displays 7 Inthe Date Display Menu select Format Settings 2 Check either Month Date Year or Date Month Year Select the Date Display Format OK 0K Button Month Day Year Cancel _ Day Month Year Help The selection will be used throughout the application 3 By clicking the OK button the setting will be completed Getting Ready 8 Quick Start TR 7U TR 50U When Windows is started the TR 71U TR 72U TR 73U TR 50U Quick Start Program from here Quick Start will be automatically started When a TR 50U or TR 7U Series device is connected to your computer the Quick Start will make a search and automatically open the application Quitting Quick Start How to Restart Again Please see below for how to quit the Quick Start function and how to restart again 9 Quitting from the Taskbar 1 Click the Quick Start icon in the Task tray to view the popup menu in the popup menu click on Quick Start Settings Click the Quick Start icon 2 Place a check next to Do not use TR 71U TR 72U TR 73U TR 50U Quick Start and click the OK button Check here woh Sim penr A tm mamaaa a ate a Aragi epa s Ss ii Re start from the Start Menu From the list of programs in the Window s Start Menu click on T amp D
11. be carried out with the Computer 2 Inthe Communication Menu click Adjustment Settings to open the settings window Send Settings _ Button Be aca Brims A te Button i mmama C LET ACH i haere History Column 3 Place a checkmark next to either 1 Point Adjustment or 2 Point Adjustment and enter the Before and After values For more about guidelines for adjustment see p 30 4 By clicking the Send Settings button a confirmation message will appear 5 Click the OK button to transmit the settings to the Data Logger Default Button This will return to settings with no adjustment applied History Column The latest 4 adjustment history records will be displayed The records show the date and time that adjustment settings were made the adjustment point s and the values for Before and After adjustment Basic Function TR 51S 52S 44 Temperature Humidity Graph Open the Graph display by clicking the icon Temp Humid Graph in the Main Window Open by selecting Open Temp Humidity Graph in the File Menu of the TR 71U 72U 73U TR 51A 52 TR 51S 52S Settings and Communication Window If you have checked After downloading automatically display graph in the detailed settings the graph program will automatically open NOTE When viewing a Graph small differences in time may occur For details see Troubleshooting on p 64 45 Temperatu
12. cannot be read into T amp D for Windows graphs 59 Temperature Humidity Graph Opening Saved Files To open a previously saved file designate the file name to open it 1 Click Open in the File Menu 2 Select the name of the data you wish to open and click Open to view the data in graph form aoe ___s Dom Select a file Selected File Name button Selected File Info Temperature Humidity Graph 60 Reinstalling the Software Before reinstalling or updating the software make sure to carry out the uninstall program first Before you begin the uninstall program first make sure to quit all T amp D Recorder for Windows programs 1 In the Windows Control Panel click on Add Remove Programs 2 From the list of currently installed programs select T amp D Recorder for Windows and click the Change Remove button 3 The Install Shield Wizard will appear Check Remove and click Next Wek ome Meddhy epa a amoa Pee pogan Witeane to fio TID Sosnin i winie Ste Lenp Martensnce pogam The pogan ei you miy the operi netaheton Chet one of he oporu bekos Monty Select nee GOJA components 12 aid OF cI CLamendly restating componenh te emere Apa F Rensa af magam comeonert rabe by the renas rete Check Remove i T Remar s rt aked menr erd me Next Button 4 Follow the directions to Uninstall 5 To reinstall follow the directions to Install
13. completed a message will appear click the OK button to activate the settings Stop Recording Button Clicking this button will stop a recording session already in progress Receive Settings Button Clicking this will allow you to view recording condition settings and recording status information from the data logger Basic Function TR 71U 72U 73U 20 TR 71U 72U 73U Downloading Recorded Data Connect a TR 71U 72U 73U unit to your computer so that communication can occur Please see p 14 for more information about how to connect The first time you connect it is necessary to install the USB device driver For information about how to install the device driver please see the TR 71U 72U 73U User s Manual 1 In the Main Window click on the TR 71U 72U or TR 73U icon 2 Click on the icon of the data logger you wish to download data from 3 Click the Download Recorded Data tab Download Recorded Data Tab f iiaia m Select a data Download logger Ce C e button ee bam oy et e g r rum Detailed Settings Button ee Se hoe area vitae Hanah on aes a i Ti Pie Lh ii HA Pe antes eee Site te bit mee here O12 ee te Lo tees oad Fie a An Wikies ot eis me ET 7 i i A J 4 If you wish to automatically display the graph upon the completion of downloading click the Detailed Settings button to make such a setting For more information about Detailed S
14. improve for all measuring ranges 1 Check the channel you wish to adjust Check here et aad Bee Chei Ss 1 Phan Saat aoe oe Send Settings Save File Button Read File Button Check one and enter the value History Column 2 Place a checkmark next to either 1 Point Adjustment or 2 Point Adjustment and enter the Before and After values 3 By clicking the Send Settings button the adjustment settings will be completed The data logger can store up to 4 adjustment values the adjustment history will display up to 4 channels at one time 29 Basic Function TR 71U 72U 73U 1 Point Adjustment This adjustment method changes only the offset b where the slope a is considered 1 For example TR 71U is measuring 10 C but the standard says the actual measurement should be 10 2 C Enter 10 in the Before Adjustment box and 10 2 in the After Adjustment box The conversion equation will be Y X 0 2 and for all measurements an adjustment to the offset of 0 2 will be made 2 Point Adjustment The adjustment equation will be calculated from two points the slope a and the offset b For example the TR 71U reads 0 C when the standard thermometer reads 0 4 C and TR 71U reads 10 C when the standard says the true measurement is 10 2 C In this case the slope a is 10 2 0 4 10 0 0 98 The offset is 0 4 so the conversion equation becomes Y 0 98X 0 4 The range of the s
15. logger you wish to make settings for 3 Click the Start Recording tab and make the necessary settings Start Recording Tab SS pe pmm Po ee T Sa zs Button f towne eiia Click on P ai Start Recording the icon e pensite g Sees Button panam Be Recording Beraes Letina Receive Settings Button Recording Start Date Time Selections Programmed Start Immediate Start Programmed Start recording will start on the specified date and time Immediate Start recording will start immediately upon completion of settings Recording interval Select from 1 2 5 10 15 20 30 seconds1 2 5 10 15 20 30 60 minutes Click on V and select the desired recording interval from the drop downlist 19 Basic Function TR 71U 72U 73U Recording Mode Selections One time Endless One time When the possible number of recorded data readings 8000 readings per channel is reached recording stops Endless When the possible number of recorded data readings is reached the oldest data is overwritten and recording continues Device Name Channel Name Make settings for each data logger concerning the device names and channel names Device Name Up to 16 characters Channel Name Up to 8 characters 4 After having completed the recording conditions settings transmit the settings to the data logger by clicking the Start Recording button 5 After the transmission has been
16. the Warning Settings button Under the Start Recording tab click on the Warning Settings button to open the Warning Settings window 1 Place a check next to Set Limits 2 Settings can be made for the Upper and Lower Limits as well as the Judgment Time The Upper Lower Limits must be set in a range from 60 C to 155 C The judgment time can be set from the following selections 10 15 20 30 seconds or 1 2 5 10 15 20 30 60 minutes By placing a checkmark the settings for that item will become active OK Cancel Button Button 3 By clicking the OK button a confirmation message will appear 4 By clicking the OK button you will be returned to the Start Recording Tab window Judgment Time A warning occurs when either the set upper or lower limit has been exceeded or when the judgment time has been exceeded Upon a warning the warning LED on the TR 51S 52S will flash and a warning mark will appear in the display Starting the Warning Monitoring Function If these settings are made in an environment where one of the limits is being exceeded and recording is started the monitoring function will enter wait mode Once the current measurement falls within the set limits the monitoring function will begin to operate 39 Basic Function TR 51S 52S TR 51S 52S Downloading Recorded Data 1 Set the Data Logger so that communication can be carried out with the Computer N Open the D
17. the list the Menu will be displayed Hoh Lom Ang Cae Senge yee Lome ostes j en Ce wne eg f D p gt Dele Tee Pret Preven 52 30 2063 1321 2 20 2003 LIAI Font pe a0 2eed LAAI 12 20 2009 12113 Daplay Lre ELADO LAIA Change Coke d 2 20 2083 122113 lt Daria ires wth no Jata pennan oria 49 Temperature Humidity Graph Graph Maintenance Changing graph display colors from the View Menu You can change the letters used in the data list display for each channel between monochrome and channel color View Menu Se fe Se a a ee ee lala 7 a Queer Chere Cobre m Dats Deeply Cory Dane at Display Carb W Selected Chomel ON OFF EF Joto Matuster The letter colors will be changed Selected Channels ON OFF from the View Menu 1 By moving the mouse to Selected Channels ON OFF the channel numbers are displayed 2 Click the channel number you wish to view or hide Co Check args Channel Goirt Date apie i Data Lt Centar izg Paap Rabti v Channel03 Ctri 3 Channel0 Ctri 4 w Channel0S Ctri 5 Channel06 Ctri 6 The same operation can be done by clicking on the channel number icons in the Toolbar Temperature Humidity Graph 50 Set High Low Average Calculation Range from the Tools Menu Tool Menu 1 Set the calculation range in the Set High Low Avg Calculation Range box fom ii r d 8 ES Bu
18. 2 Click OK to complete the setting 3 After completing settings please close the TR 71U 72U or TR 73U program and reopen it to make settings effective 31 Basic Function TR 71U 72U 73U TR 51A 52 Basic Functions Connect the TR 51A 52 to your computer to enable communication Please make sure that your computer clock settings are correct See P13 for details about how to connect Before Using This section explains operations for when using with either Communication Port TR 50C When using with Communication Port TR 50U please take note of the following Although the Settings window layout is different the contents are the same 2 The communication speed for downloading and other communications will be the same as with our older models 3 If Quick Start is enabled by placing a TR 5 Series Logger on top of a TR 50U to make recording settings or download data the software will automatically be opened If Quick Start has been disabled please open TR 5S from the launcher menu and carry out the desired settings and or communication Set the Recording Conditions 1 Inthe Main Window click the TR 51A 52 icon 2 Click the Start Recording Tab and make any necessary settings Start Recording Tab Dewrioed Recorded Date Sit Newardng Commurncsten Port Seling Typ Charwet N sve Prenat Dain me Start Recording tes r ated n7072 T OTRE 10 2 12 Receeding Sasi Oae Tee Es Freth Date Time Ofe
19. D SUB 25 pin female to a D SUB 9 pin male Q The date and the time of the recorded data are different from the actual date and time of recording Why A The Thermo Recorder has no internal clock When you set up a programmed recording start or when you download data the date and time that are shown are taken form your computer s clock If your computer s clock is not correct it will affect the recorded data A When recording mode has been set to Endless and Recording Start was carried out via PC the time for recorded data is calculated from the recording start date and time and will appear correctly in the Graph as long as recording capacity has not reached its limit However once data capacity has become full and the oldest data is overwritten the date and time for downloaded data in the Graph will be calculated using the PC s clock for the latest recorded data and subtracting backward Hence the time for the displayed data will be different from the actual time the data was recorded Other 64 Specifications Compatible Devices Data Logger Data Comm Devices TR 71U TR 72U TR 73U TR 51S TR 52S TR 51A TR 52 TR 50U TR 50C To properly use a Data Logger in the TR 5 TR 5S Series it is necessary to use in conjunction with one of our Data Communication Devices CommunicationFunctions TR 7U Series Start Recording Immediate Start Programmed Start Stop Recording Get Unit Settings Channe
20. K you can close the window Basic Function TR 51A 52 Recording Start Settings Display for TR 50U When making settings via a TR 50U the layout for the Settings display will be as below The contents of the settings and the procedure are the same Feri ate tee ao tasa ee age F maT Sear ar tae aril Se ARRONA mig weer aon Basic Function TR 51A 52 34 TR 51A 52 Downloading Recorded Data Connect the TR 51A 52 to your computer to enable communi cation See P 13 for details about how to connect 7 Inthe main window click the TR 51A 52 icon 2 Click on the Download Recorded Data tab Download Recorded Data Gad fo Gad E aio Tema aed Date Stat Recening Commascaton Por Sating Download Lomad Satu eo Button mc emmen Gentes jatteeied Dent Sew Detailed Settings Battery Lee Recording Mode Button Shae Oae and Tae Raaden Hem w 5 x n 1a 3 If you wish to automatically view the graph after downloading click the Detailed Settings button and make the appropriate detailed settings See P 36 for more info about Detailed Settings 4 Click the Download button to start downloading 5 After downloading has been completed the graph will be displayed 35 Basic Function TR 51A 52 Detailed Settings You can make settings for the processing of the downloaded recorded data 7 Select the desired processing method 2 Click OK button to complete the setting
21. NRT i mm a Hea Default File Name Cea semana Settings id ee ee am Pra era LMT IM ee ee peed ii etry Asian Pais naina 1 Check which type of file name you wish to use to save data Example Device Name Refrigerator Serial No 00001234 Date and Time 2003 05 12 yyyy mm dd at 14 30 15 with Data Format Extension TRX Device Name Date Time Refrigerator_20030512_143015 trx Internal ID Date Time 00001234_20030512_143015 trx Device Name Internal ID Date Time Refrigerator_00001234_20030512_143015 trx Date Time Device Name 20030512_143015 Refrigerator trx Date Time Internal ID 20030512_ 143015 _00001234 trx Date Time Device Name Internal ID 20030512_143015_Refrigerator_00001234 trx 2 Byclicking the OK button the settings will be completed 23 Basic Function TR 71U 72U 73U Saved Folder Settings Assign a saving location for the data file Linkin hma fon ae TS wer age L 0K area atts pe Tine Dra Button O en Glam O Dra Sapo lige rete oO mm O Destes Decs lam hets Saving Location Dae imme r aie i AS de e a E Click here r Select Folder Button 1 The TR 71U TR 72U TR 73U unit s connected by USB cable to your computer will appear in the list 2 Click the name of the device and then click the Select Folder button 3 The Browse Folders dialog box will appear where in you can select the folder into which yo
22. Operating the Graph 56 Graph Menu 56 Vertical Axis Settings AUTO in Default Settings 57 Saving Recorded Data 58 Creating Text File 59 Opening Saved Files 60 Other Reinstalling the Software 61 Troubleshooting 62 Specifications 65 What is T amp D Recorder for Windows An Overview T amp D Recorder for Windows is a software program that enables you to easily make recording settings for our data loggers download recorded data from the loggers and then process that data into graphs tables and or save that data to files or print Upon opening T amp D Recorder for Windows a launcher program will appear with several icons lined up By clicking on an icon a settings communication display for the selected type of device or a graph display will appear In order to use the software the following operational environment is necessary OS Microsoft Windows 98SE Me English Microsoft Windows 2000 XP English PC CPU PC CPU IBM Compatible equipped with more than Pentium 90MHz or NEC 98 Series USB Port Serial Port RS 232C D sub 9pin Software Microsoft Internet Explore 5 01or higher RAM More than 32MB Operating Environment A Stable Windows Operating Environment 1 Introduc
23. Recorder for Windows Quick Start to restart the application Getting Ready Quit Start from each application 7 Click on one of the icons TR 51S 52S TR 71U 72U or TR 73U in the 2 Launcher Window Click Software Settings in the Settings Menu Settings Menu Remove the check mark from next to Uppon Connecting a Thermo Recorder open the software program and click the OK button With no checkmark Quick Start will be disabled With a checkmark Quick Start will be enabled ove Canaria a Tiia iier again tha gaitera DE 0K l comu Button Temp Un io be dupisped in Scffeeare Program D Taisia faible Getting Ready 10 11 Connecting a Data Collection Device to the Computer Connecting with a USB Cable Connect the USB cable US 15C to your computer USB Cable _ l USB mini B Plug TR 50U USB Port Mark The USB cable is a USB A Plug USB mini B plug type Please connect to a place with this kind of mark NOTE Before using it is necessary to have installed the USB device driver For details about the driver installation see the User s Manual that came with the product Make sure that the USB cable is inserted fully so as not to cause an improper connection Make all necessary Communication Port Settings in the Settings Communication window for the Data Logger you are using For details see Co
24. d service may be terminated without advance notice to the user In such a case T amp D Corporation shall not be responsible for any damages whether direct or indirect from the inability to use T amp D Recorder for Windows T amp D Corporation has no obligation to correct any defects found in T amp D Recorder for Windows Copyright The Copyright for T amp D Recorder for Windows including the program and relevant documents belongs solely to T amp D Corporation The reprinting or redistribution for commercial purposes whether in part or in whole in magazines or as a part of any product is strictly forbidden without the expressed consent of T amp D Corporation Any inquires concerning commercial redistribution should be directed to the Sales Department of T amp D Corporation Please do not attempt to make any changes or modifications to T amp D Recorder for Windows Introduction i Table of Contents Introduction Notices about this User s Manual i Software User Agreement ii Table of Contents iii What is T amp D Recorder for Windows 1 Getting Started Basic Operations 3 Getting Ready Installing the Software 5 Using the Software 6 HOW to Open 22nnnnn nnn nnn nnmnnn 6 A Launcher Program 6 HELP 2 2 02 nnn nnn
25. ettings see p 22 5 Click the Download button to begin downloading data 6 After downloading has been completed a graph will be displayed 21 Basic Function TR 71U 72U 73U Detailed Settings Make settings about how to process downloaded recorded data Graph Display Settings lt i L w e OK Button File Name Settings Graph Display Settings By checking here the graph for the downloaded data will automatically appear after downloading is completed Up to 8 channels of data can be simultaneously displayed NOTE If there are more than 8 channels of data that data cannot be displayed automatically and must be opened from the data file File Name Settings You can choose to save downloaded data using a default file name or by assigning a name each time 7 Choose the type of processing you desire 2 By clicking the OK button the setting will be completed You can specify the type of default file name under File File Names and Folders Basic Function TR 71U 72U 73U 22 TR 71U 72U 73U Other Functions Open Temp Humidity Graph from the File Menu Opens the Temperature Humidity Graph File Names and Folders from the File Menu Specify how you wish the files to be named upon downloading recorded data Also you can select in which folder to use to save data for each device beim Tike Pim Cea aga 1 Fp Bagh Dag Ti 2c OK Dimi ie Button Check one from the aE P
26. evice List click this to search for Thermo Recorders by scanning the USB ports Device Name Settings from the Settings Menu Settings can be made for Device Names and Channel Names TR 71U 72U Sere Settng Send Settings OM fleet pr Button Enter a name TR 73U serdSen Send Settings Button Enter a name Ce 7 Enter a name Device Name up to 16 characters Channel Name up to 8 characters 2 By clicking the Send Settings button the changes will be completed Basic Function TR 71U 72U 73U 26 LCD Display Settings from the Settings Menu Settings can be made for the Thermo Recorder s LCD display such as changing the temperature unit and turning the display on or off TR 71U 72U Check one of these Temp Unit in Diaplay en om Seed Sete Send Settings Button TR 73U Tanp Ur i Decay Plow SiE Check one of these C Fainal TAFE LET Diiiplag Pathar Button C Dipi on Bh t T Daak ony ha C Dily ory Ch Hee 1 Check either Celsius or Fahrenheit 2 By clicking the Send Settings button the changes will be completed 27 Basic Function TR 71U 72U 73U LCD Display Pattern TR 71U 72U You can select the LCD display from 3 patterns Alternate display between Ch 1 and Ch 2 Display Ch 1 only or Display Ch 2 only Send Serge Send Settings i Button Abemge Diaptay beween Ch 1 Check one C Diply ory h1 o
27. f these e nahin o 1 Check one of the patterns 2 By clicking the Send Settings button the changes will be completed LCD Display Pattern TR 73U You can select the LCD display from 4 patterns Alternate display among Ch 1 Ch 2 and Ch 3 Display Ch 1 only Display Ch 2 only or Display Ch 3 only Tomp Ura in Dagi opi ca sasur Send Settings LED Ciiipias Pacer Button Check one of these C Dipy oni Eh T C Diy andy h Obay rithi Hee 1 Check one of the patterns 2 By clicking the Send Settings button the changes will be completed Basic Function TR 71U 72U 73U 28 Adjustment Settings from the Settings Menu By setting adjustment values beforehand you can record and display the post adjusted measurement values You can choose from two adjustment methods 1 point and 2 point Adjustment will be carried out using an adjustment equation of Y aX b where X is the pre adjusted measurement value and Y is the post adjusted value Rough Guidelines for Adjustment 1 point Adjustment Use when measuring in a range of 20 C 2 point Adjustment Use when measuring in a wide range NOTE When adjusting at 2 points make sure the difference in points is at least 10 C When measuring in a wide range and adjusting at 2 points make sure that the adjustment values reflect the range you are measuring We cannot guarantee that after carrying out adjustment the measuring accuracy will
28. ft Internet Explore 5 01 or higher More than 32MB A Stable Windows Operating Environment 65 Other For product information or questions contact us at T amp D corPorRATION 5652 169 Sasaga Matsumoto Nagano JAPAN 399 0033 Tel 81 263 27 2131 Fax 81 263 26 4281 E mail overseas tandd co jp Office Hours Monday to Friday 9 00 12 00 13 00 17 00 GMT 9 00 Tokyo Time Home Page http www tandd com We have opened an English Homepage called T amp D Online for your convenience Here you can find information about our company news products upcoming events software and user s Manual downloads as well as other support Please stop by and see what we have to offer T amp D Recorder for Windows TR 5 7xU User s Manual Published by T amp D CORPORATION Copyright 2002 2007 T amp D Corporation All rights reserved This is printed on recycled paper
29. gerteet o s am i 22 7 200 O imedate Stat 10 v 0 14 0 00 Pecorino rter a Mecording Mode Une of lerperstue One Time Ort T o Endiiess Loop Basic Function TR 51A 52 32 33 Type Select TR 51A TR 52 Select depending on the device you wish to make settings for Channel Name Channel names can be entered with up to 8 letters Recording Start Date Time Select Programmed Start Immediate Start Programmed Star Recording will begin on the day and time entered Immediate Start Recording will begin as soon as settings are completed Recording Interval Select from 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes By clicking V you can select from the recording interval list TR 51A cannot be set using seconds Recording Mode Select from One time Endless One time When the number of readings has reached 16 000 the unit display will read FULL and recording will automatically stop Endless When the number of readings reaches 16 000 the next one will overwrite the oldest or first reading Unit of Temperature Select from Celsius C or Fahrenheit F Change the display of temperature on the data logger between C and F 3 After making all the desired settings click the Start Recording button to transmit them 4 After transmission has been completed the communication result will appear By clicking OK the set up process will be finished By clicking O
30. gs in Detailed Settings before downloading you can specify whether or not you wish to display a graph upon downloading as well as specify file names for saving files w Introduction TR 5 Series Installing the Accompanying Software If Quick Start is enabled by placing a TR 5 Series Logger on top of a TR 50U to make recording settings or download data the software will automatically be opened If Quick Start has been disabled please open TR 5S from the launcher menu and carry out the desired settings and or communication Connect the Main Unit to the Computer Place the data logger in a position to enable communication with your computer Communication Port Settings Making Recording Start Settings i Before making Recording Start settings make sure that your computer s date and time settings are correct If the date and time settings are incorrect it will have an effect on the recording start time Download Recorded Data By making detailed settings before downloading data it is possible upon the downloading of data to automatically open the Graph or assign file names for saving NOTE Before downloading data make sure that your computer s date and time settings are correct If the date and time settings are incorrect it will have an effect on the downloading date and time A Introduction Installing the Software Is Windows operating properly If Windows is not operating properly T am
31. hermo Recorder for Windows 4 11 E please refer to the PDF file contained in the CD ROM USB cable already connected to computer NOTE To communicate with a TR 71U 72U unit via serial communication cable please use our optional serial communication cable TR 07C If the place of connection is incorrect communication will not occur To ensure proper communication make sure that the communication cable connection is secure Getting Ready 14 Communication Port Settings Setting Up the Communication Port for USB Communication or RS 232C Communication From the Main Window open the Settings and Communication window for TR 51A 52 and click on the Communication Port Settings Tab Select Serial Port When wishing to carry out Communication using a serial communication cable please make serial port settings Set which serial port you would like to use to communicate with the data logger There are two methods to make the settings Auto Detect and Select Serial Port Connect the serial cable to port you wish to use and then connect it to the logger Examples of serial port marks The communication cable connector is a D Sub 9 pin female SLL f Connect to a place with a mark as such If the place of connection is incorrect communication will not occur To ensure proper communication make sure that the communication cable connection is secure 15 Getting Ready Using Auto
32. isplay Items ch Drag the channel name number you wish to move to the newly desired channel name number position and drop it Name Channel Data Name Interval Recording Interval Sample Number of data Max Highest Reading CursorA Cursor A position data Min Lowest Reading CursorB Cursor B position data Avg Average Value A lt gt B Calculated Temp Humidity Unit Unit of measurement Difference between Cursor A and B When opening data recorded in TR 73U units into a graph When opening a file containing barometric pressure data thp format file the window is different from the standard with the scale for barometric pressure appearing on the right side For details see Temperature Humidity Graph Help Keyword About Barometric Pressure Scale for Barometric Pressure gt e ya oe anans aie TFT i 47 Temperature Humidity Graph Zooming In and Out on the Graph Enlarged Reduce With the left button drag the mouse to outline With the mouse right click on the graph and the area you want to zoom in on select Return to Original Size in the pop up Menu that appears oat BEES ek Y at Emr encore iaire Epa Aarde Grann Dae ET G Sema a as ete a PAL Lin iep DEDA irga ae fet hamir Lorina Teor Daras te Cnteere reer By right clicking on the graph the Menu will be displayed With Return to Original Size or Step by Step Return to Original you can return both the ve
33. l Names Recording Interval and Recording Mode also possible to make settings Download Recorded Data Gather Current Readings Adjustment Application Settings TR 5 Series Start Recording Immediate Start Programmed Start Download Recorded Data TR 5S Series Start Recording Immediate Start Programmed Start Stop Recording Get Unit Settings Download Recorded Data Warning Settings Adjustment Application Settings Temp Humidity Graph Graph Temp Humidity Graphs for Each Channel Zoom out sin and scroll Change Channel Colors Turn ON and OFF Channel Display Data Display Channel Name Recording Interval Number of Readings Number of Channels Others File Output Highest Lowest and Average Reading Unit of Measurement AB Cursor Dates Times and Data Readings Calculated Difference between Cursor A and B 8 Channel Simultaneous Display and Processing Data List Display Calculation Range Settings Data Maintenance Edit Recording Conditions Delete Data by Channel Re order Data by Channel TR Series Common Data Files trx Text File CSV etc Selected Range File for selected time period Printing Graphs Tables Compatible OS PC CPU Software RAM Operating Environment Microsoft Windows 98SE Me English Microsoft Windows 2000 XP English PC CPU IBM Compatible equipped with more than Pentium 90MHz or NEC 98 Series USB Port Serial Port RS 232C D sub 9pin Microso
34. ll appear Menu Bar The menus along the bar contain various helpful commands From each menu you can select commands to view or make settings for each of the device types Icons By clicking TR 71U 72U TR 73U TR 51A 52 TR 51S 52S and Graph icon you can open the Settings and Communication Display You can also open the Settings and Communication Display from the Start Menu in the Menu Bar Getting Ready 6 HELP For more detailed assistance on using the software see the Help menu contained in the software By clicking on Help in the Menu Bar and then Search by Topic you will find three tabs Contents Index and Search to click on to help you search for the topic you are unsure about or have questions about 7 Contents Index Search Contents By clicking on the classified topic cS mark you will find explanations concerning that topic Index Select a keyword from the keyword list and by clicking the Display button the explanation for that topic will appear Search Enter the keyword you wish to search for and click Start Search All topics containing that keyword will be displayed Select a topic and click the Display button to display the explanation for that topic NOTE appear By clicking the G Toolbar in the Graph Display you can then view explanations for menus icons and objects in the Main Window by clicking the question mark arrow on those items Getting Ready Date
35. lope is O lt a lt 2 Entries are valid to one decimal point but after calculation up to four digits are valid for the slope and offset Save File Button Assign a name to the adjustment setting values and save them to a file Read File Button Read adjustment setting values from a saved file Basic Function TR 71U 72U 73U 30 Software Settings from the Settings Menu General software settings for TR 71U TR 72U TR 73U can be made here Upon connecting a Thermo Recorder open the Software Program This setting opens the software program upon the connection of a TR 71U TR 72U TR 73U unit via USB cable If the setting is ON the Quick Start Program will periodically communicate with the device driver and upon the detection of a USB connection will open the main software program For more details about Quick Start and how to quit it see P 9 1 Place a check next to Upon connecting a Thermo Recorder open the Software Program With no checkmark Quick Start will be disabled With a checkmark Quick Start will be enabled C om Button 2 Click OK to complete the setting Temp Unit to be displayed in Software Program Select whether to use Celsius or Fahrenheit as the displayed unit of temperature when monitoring current readings and using the adjustment function 1 Check either unit of temperature Celsius or Fahrenheit a CEO OK z Button Check here yO puma mi ee emae
36. mmunication Port Settings p 15 TR 5S has no communication port settings Getting Ready Connecting with an RS 232C Serial Cable to the Computer Connect the serial RS 232C communication cable to your computer _ RS 232C Serial Cable TR 50C Examples of serial port marks The communication cable connector is a D Sub 9 pin female apie Connect to a place with a mark as such NOTE Make sure to connect it to the correct place to ensure communication Make sure that the cable is inserted fully so as not to cause an improper connection Make all necessary Communication Port Settings in the Settings Communication window for the Data Logger you are using For details see Communication Port Settings p 15 TR 5S has no communication port settings Getting Ready 12 Connecting the Data Logger to the Computer Connect the Data Logger to the computer using the appropriate method for that type of Data Logger When using a Data Logger with Optical Communication Compatible Loggers TR 51S 52S TR 51A 52 51 7 Connect the Communication Port to your computer using the provided communication cable Communication Cable Communication Port 2 Place the Data Logger on top of the Data collection device as shown in the figure making sure that the optical communication spots are aligned properly
37. n be carried out with the Computer 2 In the Download Recorded Data Tab Window click the Warning Times Button Download Recorded Data Tab Warning Occurrence Time Column Receive most recent time Button Warning Times Button 3 By clicking the Receive most recent time Button it is possible to check warning times in the Warning Occurrence Time Column NOTE Even if more than one warning occurred only the first one will be shown in the most recent list 41 Basic Function TR 51S 52S Removing a Warning Mark from the Data Logger Display A warning mark can be removed from the Data Logger display by one of the following three methods Download Data Once data downloading has been successfully completed the warning mark will disappear Re start a Recording Session The mark will disappear whenever a new recording session is started Remove from the Warning Times Display 1 Open the Warnig Times Display by clicking the Warning Times Button in the Download Recorded Data Tab Window Warning Occurrence Time Column ae mr e I Clear Occurrence Times from Main m E Unit Button i 2 Click the Clear Occurrence Times from Main Unit button to complete the removal This will have no effect on the already recorded data measurement and recording will continue without interruption Confirm that in the Warning Occurrence Time Column None appears
38. nat to armen fom graph e ok button ceca capil Check me Shift Unit C F From the Tools Menu By clicking on Shift Unit C F you can automatically change the temperature unit scale in the graph display and in the channel info list Temperature Humidity Graph 54 Change Graph Colors from the Tools Menu om ai _ e OK da e e S rep te reper eer Button iiss 2 i se o l si J HEEE Default Button s em Hinnan GIN ine Width Gamo eee Button g Damm in a Color Sample an ree amp nes Pe Bnet om ow AD Ow Tes Sens tw e te ee t er Ete fe toe ow eee cate vevatubaardinp canto aeenaseae 1 Click the channel number of which you wish to change the color 2 Byclicking each button color samples will be displayed Choose the color you want and click the OK button 3 After confirming the color by clicking the OK button the change will be completed By clicking the Return to Default button you will return to the color settings when the software was opened Line Width Button Change the width of the data lines and or the scale lines oe OK Button torre ott Default button Every time you click on A the numerical value gets larger Every time you click on w the numerical value gets smaller Copy Display to Clipboard From the Tools Menu By clicking Copy Display to Cli
39. nec nn nnn nn cnn nec nenee tens 7 Date Display Format Settings 8 Quick Start TR 7U TR 50U Quitting Quick Start How to Restart Again 9 Connecting a Data Collection Device to the Computer Connecting with a USB Cable 11 Connecting with an RS 232C Serial Cable to the Computer 12 Connecting the Data Logger to the Computer When using a Data Logger with Optical Communication 13 When using TR 71U 72U 73U 14 Communication Port Settings Select Serial Port 15 Using Auto Detect 16 Select Serial Port 16 Basic Functions TR 71U 72U 73U Basic Functions Display Names and Functions 18 Starting Recording 19 Downloading Recorded Data 21 Detailed Settings 29 Other Functions Open Temp Humidity Graph 23 File Names and Folders 23 Large Icon Small Icon 24 Monitor Current ReadingS 25 Search for TR 71U TR 72U TR 73U 26 Device Name Settings 26 LCD Display SettingS 27 Adjustment Settings 29 Software Settings
40. nication via USB connection We recommend I O DATA USB RSAQ3 ELECOM UC SGT and IOGEAR UC 232A Serial USB conversion cables If you are using an NEC Lavie J Notebook Computer NEC LJ 500 please use I O DATA USB RSAQ3 Sometimes communication will not work if a switch has been added to the serial port RS 232C or an extension cable has been added to the communication cable Check to see if some other communication software is in use If your desktop computer has two serial ports try connecting the communication cable to the other port and try communicating again Other Q I can t get the communication cable connected to the computer What should I do A Please connect the communication cable provided with the Thermo Recorder into the serial port of your computer D SUB 9 pin male connector If for some reason you cannot connect directly please use an appropriate adapter gender changer plug as explained below o o oJ o D SUB 9 pin male D SUB 25 pin female Half pitch 14 pin female If the connector on your computer is a D SUB 9 pin male then there is no need for an adapter If the connector on your computer is a D SUB 25 pin female then use an adapter D SUB 25 pin male to a D SUB 9 pin male If the connector on your computer is a Half pitch 14 pin female then use the adapter Half pitch 14 pin male to a D SUB 9 pin male or a combination Half pitch 14 pin male to D SUB 25 pin male and
41. o use with a mixture of device types TR 5S TR 5 and TR 7xU It is possible to process recorded data from a mixture of device types This manual has been written using C as the standard unit of temperature User s in the United States and elsewhere who would like to change the unit to Fahrenheit can easily do so by making changes in the Shift Unit under Editing the Graph Introduction 2 Getting Started Basic Operations TR 7xU TR 5S Series Connecting the Unit to your Computer Connect the USB cable and set up so that the data logger and your computer can Installing the USB Device Driver Q fe 3 3 E 5 Q D By installing the USB device driver your computer will be able to recognize a TR 7xU TR 5S unit when it is connected For more details about how to install the driver see the Data Loggers Hardware Manual Installing the Accompanying Software After installing T amp D Recorder for Windows each time Windows is opened the TR 71U 72U 73U 50U Quick Start will automatically be activated If you do not wish to use TR 71U TR 72U TR 73U TR 50U either close or delete the Quick Start program see page 9 Making Recording Start Settings Before making Recording Start settings make sure that your computer s date and time are correct If your computer s date and time are incorrect it will have adverse effects on the starting time for recording Downloading Recorded Data By making settin
42. operties Menu Bar The menus along the bar contain various helpful commands From each menu you can select commands to view or make settings for each of the device types Toolbar The commands that are used most frequently have been arranged as buttons Device List TR 71U 72U 73U units connected to the computer by USB cable will be displayed as icons here In order to make recording settings or download recorded data it is necessary to first select a device from the device list The type of icon used in the display can be changed in the View Menu Device Properties Information about the device selected in the device list will be displayed here If more than one data logger has been selected no information will be displayed Settings Area By clicking on the Download Recorded Data tab or the Start Recording tab you can open the settings display for that function Basic Function TR 71U 72U 73U 18 TR 71U 72U 73U Starting Recording Connect a TR 71U 72U 73U unit to your computer so that communication can occur Please make sure that your computer clock settings are correct Please see p 14 for more information about how to connect The first time you connect it is necessary to install the USB device driver For information about how to install the device driver please see the TR 71U 72U 73U User s Manual 1 In the Main Window click on the TR 71U 72U or TR 73U icon 2 Click on the icon of the data
43. ort TR 50U When using with either Communication Port TR 50C please take note if the following TR 51S will be recognized as TR 51A and TR 52S will be recognized as TR 52 for more details about operations see from p 32 2 Some functions such as Warning Settings and Adjustment cannot be used 3 The communication speed for downloading and other communications will be the same as with our older models Set the Recording Conditions 1 Click the Start Recording tab and make the necessary recording condition settings For details about the various items and buttons please see the next page Recording Start Tab Pee es eo ae Sealer Earl Mate Bimar ay Moe merir ate T oran ar Fin mia o Recording Start ante Bet Ciia ETE Button erag hia art fom te Fenn eTa M Detailed Settings APP AENT B a Button Senos G Recording Start Secordeg interval Tarei See J Button ines Dm Arigna a e Warning Settings Uni oo Lapa Button Cre 2 Click the Start Recording button to transmit the settings 3 After the transmission result message appears click the OK button to complete the setting procedure 37 Basic Function TR 51S 52S Recording Start Date Time Programmed Start Recording will begin on the set date and time Immediate Start Recording will begin once settings have been completed Recording Interval Selections 1 2
44. ownload Recorded Data Tab Display ad With Detailed Settings it is possible to make settings for what type of processing you wish to occur after downloading Download Recorded Data Tab Download Button Place a check here if i i you wish to specify data by time a Detailed Settings Button 4 If you wish to download all of the data simply click the Download button 5 If you wish to specify data by time for downloading choose the time range and click the Download button Detailed Settings Button This opens the window in which settings for the processing of data after it has been downloaded can be made Select from the four processing methods _ OK Button we Destination Folder Settings Button Selecting the Data Processing Method A Graph will automatically be shown Assign a File Name for the saved data Assign a File Name for the saved data and automatically show graph Automatically save file Click the Destination Folder Settings button to specify the file saving location A file with the name download date and time_channel name trx will be saved in the specified folder Basic Function TR 51S 52S 40 TR 51S 52S Other Functions Checking for Warning Occurrences from the Warning Times Button Here it is possible to check the time s of warning occurrences 1 Set the Data Logger so that communication ca
45. p D Recorder for Windows may not be installed correctly or it may not operate properly Please quit all other applications If other programs are open please close and quit all of them making sure to quit all Quick Start programs such as a virus checker 7 Open Windows 2 Place the accompanying CD ROM into your CD ROM drive In a few seconds the Install Program window will appear If that window does not automatically open please open it by double clicking the CD ROM icon in My Computer on your desktop Install T amp D Recorder for Windows anal TED Biusi meg FD Pomjan ber Wima TAK JL TR 5 7xU 3 Select Install T amp D Recorder for Windows and click the Execute button to start the installation 4 To continue installation follow the directions as they appear After installation has been completed the program T amp D Recorder for Windows should appear in the Start Menu will be registered in the Start Menu s Start up Program 5 Getting Ready Using the Software How to Open To open in the Windows Start Menu under Programs click T amp D Recorder for Windows Quick Start All Programs r Recorder for Windov TR F BOE i T eee ee wv Wind A Launcher Program Upon opening T amp D Recorder for Windows a launcher program will appear with several icons lined up By clicking on an icon a graph display or a settings communication display for the selected type of device wi
46. pboard you can copy the currently displayed window to the clipboard and make use of the graph by pasting to other software 55 Temperature Humidity Graph Operating the Graph from the Graph Menu Graph Menu fie ew Tools mep Corie T i siran Criat Crietught Beteu Boiteig Faita Return to Original Size Clicking here will return the graph to its original size Zoom In Zoom Out Zooms in or out one step at a time Move Cursor Right Left Simultaneously move the AB Cursors to the right or left Move Graph Right Left Move the Graph Display to the right or left Move Graph Up Down Move the Graph Display up or down Vertical Axis Settings AUTO in Default Settings Set the vertical axis scale temperature Temperature Humidity Graph 56 Vertical Axis Settings AUTO in Default Settings from the Graph Menu 1 Check either Auto or Manual AUTO The vertical axis will automatically be changed according to the values of the data MANUAL You can set the upper and lower values of the vertical axis scale TR 5 TR 5S TR 71U 72U Enter the range of the vertical axis scale TR 73U Enter the range of the vertical axis scale 2 Click OK to complete the settings 57 Temperature Humidity Graph Saving Recorded Data If you have checked After downloading automatically show graph make sure to save data after displaying the graph or editing any data 3 Ways to Save Files f
47. re Humidity Graph Display Names and Functions Graph Area The area in which the Graph is displayed The horizontal axis shows time and the vertical axis shows temperature humidity data 2 A and B Cursor Bars By clicking the arrow buttons at the left and right of the bar you can simultaneously move the A B cursors Click and drag the A or B button on the bar to move the cursor to the left or right 3 A and B Cursor Position Information The approximate date and time for the A and B cursor positions and the time difference between the A cursor and the B cursor is displayed 4 Channel Info Display The detailed data info for each channel 1 to 8 is displayed below the Graph Display 6 Menu Bar Menus are lined up which contain various commands They are used to view data or to make settings for the various functions in each menu Toolbar Icons Buttons appear for frequently used commands Horizontal Gauge Bar and Button for Moving Horizontal Axis The time axis moves by clicking the lt gt buttons at the left and right of the bar By dragging the gauge you can move left and right to the data you want to be displayed Horizontal Gauge Bar and Button for Moving Horizontal Axis The vertical axis moves up or down by clicking the V A buttons at the upper and lower sides of the bar By dragging the gauge you can move up and down to the data you want to be displayed Temperature Humidity Graph 46 Channel Info D
48. rom the File Menu Overwrite All Data Will save any changes to file without changing File Name and Saving Location The same operation can be carried out from Save in the Toolbar Save All Data as Save with a new File Name Save Display Data as Save only that data in the current display This is handy when you wish to save only the desired data EX Save All Data as 1 Click Save All Data as in the File Menu 2 Specify the Location and enter a File Name Specify Location jee Enter a File Name Save Button 3 Click Save to complete the saving process Temperature Humidity Graph 58 Creating Text File By saving the recorded data as text file you can create a file type that can be read by common spreadsheet software 1 Click Save Data in Text File in the File Menu 2 Select the Text File Type and Range to be saved and click OK Comma Tab Space and Semi colon are codes used by common spreadsheet software such as Excel and Lotus when reading Text File to divide cells Range to be saved Al data Select the Range to be e adva Saved K et OK Pe Button 3 Designate the location to which the file should be saved and click Save to create and save the data as a Text File document Select the Text File Type C Save ine Button NOTE The extension for the created file will be txt Text File
49. rtical and horizontal axis back to show the entire graph These operations can be carried out via commands in the Graph Menu or by clicking icons in the Toolbar as above About the Horizontal Axis The entire graph shows in the horizontal axis the nearest data to the recording start time and the latest data nearest the recording finish time for each channel 1 8 This represents the full scale of the horizontal axis About the Vertical Axis The entire graph shows in the vertical axis the lowest possible measurement value and the highest possible measurement value for channels 1 8 This represents the full scale of the vertical axis Temperature Humidity Graph 48 Data List Display from the View Menu This is a list of the data that was displayed in graph form Date Time Button By clicking this button you can shift the display between the recorded date and the amount of elapsed time since recording started Date Time Button Recorded Date scroll Bar Displa mer 13 p y Z C 132 H 2 30 2063 132 4 5 1491 4 Elapsed Time Display SER ESE SD Color Coded Display Green Dates and times for data which fall within the calculation range for determining high low and average measurements Black Dates and times outside the calculation range for determining high low and average measurements RED Highest Value BLUE Lowest Value PINK Average Value Menu Display Using the Mouse By right clicking on
50. takes errors or unclear explanations in this manual T amp D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product Some of our products which come under the category of strategic goods in foreign trade law need the permission of the Japanese government to be exported outside of Japan The Warranty that comes with this Manual can not under any cicumstance be reissued so please keep it in a safe place The Manual itself can be downloaded from our Home Page http www tandd com Introduction Software User Agreement Escape Clauses Although T amp D Corporation has made operational tests on our software T amp D Recorder for Windows we cannot guarantee that all operations will work properly under all conditions T amp D Corporation shall not accept any responsibility for any damage whether direct or indirect that results from the usage of T amp D Recorder for Windows Specifications of T amp D Recorder for Windows may be subject to change an
51. tion Basic Functions Recording Settings Settings can be made for recording conditions such as channel name recording interval and recording mode By making a recording start date and time setting in the main unit s the unit s will begin recording at that time on that date Graph Display Printing Simultaneous Display of 8 Ch of Data It is possible to display up to 8 channels of downloaded data in 1 graph Zoom in on Data by Mouse By simple mouse operations you can easily zoom in and out on data as well as change the display View the High Low and Average Calculations for any Specified Period Make settings to specify the calculation range you desire and view the high low and average value for that range in each channel displayed in the graph Graph Printing It is possible to print in full color the graph as you see it on display Data List Display Printing You can view the data displayed in the graph window as a list and then choose to print View in Easy to Distinguish Colors In the data list the highest value will appear in red the lowest in blue and the average in pink Printing the Data List It is possible to print the entire list as displayed or to select pages for printing Creating Text File It is possible to convert the data for a specified range time period to common text file format CSV type format so that it can be exported to spreadsheet software such as Excel or Lotus Possible t
52. tton Me Oe i eee Enter the ee ee es a a Entire Graph numerical values oe button fia By clicking the Entire Graph button the dates and times for the entire graph will be displayed If in the graph display you place the A cursor at the position for the beginning of the calculation range and the B cursor at the end of the range those dates and times will appear as the new range in the Set High Low Average Calculation Range Display when it is opened 2 By clicking the OK button the high low and average values for each channel of data in the list will be changed In the graph display the data for the calculation range that you have set will be displayed 51 Temperature Humidity Graph Edit Recording Conditions from the Tools Menu 1 By clicking the Ch button of the channel you wish to edit the Name and Started Date Time in the Edit Items display will show info for that channel number _ 0K sa Button eel Restore Button Channel Number The selected channel number Edit Items Name Up to 32 letters can be entered Starting Date Time The month day year hour minute and second can be changed 2 By clicking the OK button after changing the setting will be completed If you wish to continue to change other channels repeat the process as in 1 The Restore button is only effective while making changes After clicking the OK bu
53. tton the settings cannot be restored to the original settings Temperature Humidity Graph 52 Re order Channel Data from the Tools Menu You can re order the data during graph display There are two methods to use when re ordering channels Re order by Dragging a Channel Number and Specify the Channel Numbers to be Moved EX Re order by Dragging a Channel Number If you wish to move Ch 3 to Ch 7 Drag the channel number you wish to move Ch 3 to the newly desired channel Button number position Ch 7 and drop it eee _ ae button Re order Button k Specify the Channel Numbers to be Moved Set as such From gt Ch 3 original position To gt Ch 7 desired position then click the Re order button Click the OK button to complete the settings position Ch 7 and drop it OK Button After make the necessary settings by clicking the OK button the channels will be re ordered and the graph will be re drawn Restore Button This command will become invalid after the settings procedure has been completed and the OK button has been clicked If you wish to restore channels please re order channels again by following the above procedures 53 Temperature Humidity Graph Erase Selected Channel Data from the Tools Menu 7 Puta check on the channel number you wish to erase 2 By clicking on the OK button the deletion will be completed Gea the irana you w
54. u wish to save the data then click OK 4 A Data Folder will then appear under Device Properties in the Main Window The default setting will create and save data to a folder with the device s serial number in the same folder where T amp D Recorder for Windows was installed Large Icon Small Icon from the View Menu Changes the icon size in the Device List between large and small Large Icon Small Icon Basic Function TR 71U 72U 73U 24 Monitor Current Readings from the Communication Menu You can monitor at set intervals the current readings of data logger or loggers selected from the device list and have those readings displayed eo ke a a re brard i ee HEE bee Mam EFE Close Settings Display Settings button This opens a window where settings can be made for the display colors and the monitoring interval for current readings Close button Quit the Monitoring of Current Readings Reset button Click to reset the display for highest and lowest measurements the new display will show highest and lowest measurements from the time of resetting Graph button Click this to hide or view the graph Clear button Clicking this will clear the graph and a new graph will be drawn from that point 25 Basic Function TR 71U 72U 73U Search for TR 71U TR 72U TR 73U from the Communication Menu Ifa TR 71U TR 72U or TR 73U is connected but does not show up in the D