Home
Mantis Infrared Tire Temperature Sensor User Manual Mantis
Contents
1. Mantis Infrared Tire Temperature Sensor User Manual BY aA IR SENSOR TECHNOLOGY Contents Important Information About Your NEMS sce cee tee ira aandaa Installation oaeen Programi ccceeeeeteeeeeeenteeeeeeeaae Replacement Parts and Part Numbers ccenn TroubleShooting cccceeeeeseeeeeeeneaes Warranty Information eee For closed course competition use only Before You Get Started Important Information About Your Mantis Welcome You are now the proud owner of the Mantis infrared tire temperature sensor by Driven Racing Carefully follow the instructions in this manual to get the most use out of your Mantis 1 The Mantis infrared tire temperature sensor is for closed course competition use ONLY 2 Make sure that your bike uses a 12v battery before connecting the battery leads 3 Test handlebars after installation and prior to riding Nothing should limit the movement of the handlebars any of the controls or any other component of your bike For closed course competition use only 4 For proper adhesion of the sensor body thoroughly clean fender surface and use maximum pressure when applying Allow 1 hour for adhesive to set 5 Your Mantis is not waterproof It must not be used in wet conditions 6 When not in use always store your Mantis in a safe place away from any heat source 7 Your Mantis is not make or model specific It can be transferred from b
2. e to faulty installation will void this warranty Any Mantis with a manufacturing defect should be returned to Driven Racing Please call 818 775 0041 to obtain an RA number prior to returning defective product All warranty claims must include e Driven Racing issued RA number e Original paid and dated receipt 11 For closed course competition use only e The complete Mantis all components must be included e The complete name address and phone number of original purchaser Please return defective product to Driven Racing c o Mantis 21143 Itasca Street Chatsworth CA 91311
3. er button Mantis LCD display programming is now complete For closed course competition use only Replacement Parts and Part Numbers NEE Part Mantis IR Tire Temperature A00003 Sensor complete assembly LCD display unit 100084 Sensor stands A00008 Front sensor 100085 Rear sensor 100086 Front sensor cable 100088 Rear sensor cable 100089 Battery cable 100091 Display bracket 100077 Display bracket suction cup 100090 kit 3 pack Glue Adhesive 4 pack 100092 Zip ties 6 pack 100093 For closed course competition use only Troubleshooting Problem Unit does not power on LCD display shows lines instead of numbers LCD display numbers are flashing above and below alarm settings Solutions Make sure cable is connected securely to battery Make sure battery has power Make sure battery cable is connected securely to display unit Make sure sensor cables are connected securely to display unit Unplug and reconnect cables if necessary Reboot display unit by holding power button down for 3 seconds For closed course competition use only Warranty Information Thank you for purchasing a Mantis infrared tire temperature sensor Driven Racing is pleased to offer this limited warranty This warranty is valid for a period of 60 days from date of purchase All manufacturing defects are covered Any and all modifications to the Mantis will void this warranty Any damage du
4. ike to bike 8 Tools needed for installation are 2mm allen wrench and 10mm socket wrench to connect the battery terminals 9 Driven Racing highly recommends that installation be done by a qualified mechanic For closed course competition use only Installation and Programming Installation 1 Remove the Mantis from its surface 2 3 as j A 4 J Po f 3 packaging and lay it out on a clean 1 5 Visual Display of Parts Included For closed course competition use only Parts Included Windshield Display Bracket 1 Sensor Mount 2 Glue Adhesive 4 LCD Unit Display 1 Zip Ties 4 Battery Cable 1 Sensor Cable 2 Infrared Sensor 2 AN Oa A ON 2 Use glue adhesive provided to secure sensors to front and rear fenders Fig 2 Note Sensors must be installed at least 4 away from any heat source gt Fig 2 For closed course competition use only 3 Ensure there is a 1 5 2 5 gap between tire and sensor face Fig 3 Fig 3 4 Secure Mantis LCD display unit to windshield using bracket and suction cups provided Fig 4 Note Test handlebars for freedom of movement after installation For closed course competition use only Suction Cup Fig 4 5 Connect power cables to your bike s 12v battery 6 Run cable from bike battery to Mantis display unit Connect cable to the display unit 7 Run sensor cables from front and rear sensors
5. to the display unit Connect cables to the display unit 8 Secure cables to bike using zip ties provided For closed course competition use only Note For your safety and proper bike operation cables must be untangled and kept away from direct contact with hot parts e g exhaust and engine case 9 Turn Mantis LCD display on by pressing and holding the power button at top of unit Top and bottom readouts should be visible Programming To program the LCD display 1 Locate the Adjust and Mode buttons next to the display 2 Press Mode button to cycle through high alarm low alarm and current temperature display 3 To setan alarm press the adjust button while current temperature is displayed 4 The display will now show the high alarms with the selected alarm value 7 For closed course competition use only blinking By pressing the adjust button you will cycle your selection through the alarms High Low Front and Rear To edit an alarm value select the alarm to be edited then press the Mode button You re now editing the selected alarm value Press the Adjust button to raise the value or the Mode button to lower the value until you reach the desired value Press and hold either Mode or Adjust to save and return to the current temperature display Temperature units can be switched between Celsius and Fahrenheit by pressing without holding the pow
Download Pdf Manuals
Related Search
Related Contents
表紙~最終 ※1MBを超えるファイルです。ご注意ください Mémoire Final Micka.. PSE コンパウンドボウ 取扱説明書 HUSKY 2-YEAR LIMITED WARRANTY PROGRAM Worldwide Homefurnishings 403-135BN Installation Guide CAPILLARYS / MINICAP URINE Publications Module Copyright © All rights reserved.
Failed to retrieve file