Home

airooncentre - Air Con Centre

image

Contents

1. and service Customers outside UK see international below UK Xpelair have a comprehensive range of services including e Free technical advice help desk from Engineers on all aspects of ventilation e Free design service quotations and site surveys e Service and maintenance contracts to suit all requirements Please ask for details e By telephone on Techline 44 0 8709 000430 By fax on Techfax 44 0 8709 000530 e At the address below International e Guarantee Contact your local distributor or Xpelair direct for details e Technical Advice and Service Contact your local Xpelair distributor amp Xpelair Applied Energy Products Ltd Morley Way Peterborough PE2 9JJ t 01733 456789 Xpelair is a registered trademark of Applied Energy Products Limited f 01733 310606 Applied Energy Products reserve the right to alter product specificatioi or appearance without prior notice All finishes and diagrams in this www applied energy com booklet are as accurate as printing processes allow
2. press home the cover A until it is firmly held by the clip 7 and the catch 1 Fig T Refit the screw SL150 only The appliance must be permanently connected to a fixed electrical supply installation using twin conductor cable of at least 1 mm in section and a maximum of 1 5 mm No earth installation is required as the appliance has double insulation Class I OA IPX4 NOTE TIMER and HUMIDITY connection Must he carried out by following the wiring diagram for SL100T SLIOOHT SL150HT Connect the wires to the connection strip by using a pointed instrument the tip of a screwdriver for example to apply pressure to x xl x2 x3 and pushing the striped wires L N SL into the holes y yl y2 y3 SL100T DJA IPX4 Adjust the timer by turning the knob 4 in a clockwise direction to increase the operating time 3 15 SLIOOHT and SL1SOHT CJA IPX4 Adjust the operating time by turning the red knob 4 in a clockwise direction Adjust the level of humidity by turning the blue knob 5 in a clockwise direction to increase the level The Slimline HT series incorporate a LED indicator The LED is lit when the extractor is functioning either activated by the switch fitted to the appliance itself or another exterior switch When the extractor is activated by the level of humidity the LED is not lit When the extractor is not operating the LED does not light SL100P and SL150P LIA IPX4 This model is fitted with a Sta
3. airconcentre cou The Ventilation Specialists Quick Order Hotline vi Guaranteed Low Prices 4 0800 865 4567 vI Huge Stock Available vI Xpelair Stockist or 0121 250 2186 Mon Fri 8 30am 6 30pm Sat amp Sun 11am 5pm N N TN y yv aE wy L p E SL100 SL100P SL100T SL100HT SL150 SL150P SL150HT Slimline Axial Fan Range amp uw Installation and maintenance instructions Xp ela r airconcent cou The Ventilation Specialists vI Guaranteed Low Prices vI Huge Stock Available vI Xpelair Stockist Quick Order Hotline 0800 865 4567 Mon Fri 8 30am 6 30pm Sat amp Sun 11am 5pm SLIMLINE Series LIA IPX4 INSTALLATION Begin the installation by making a circular opening of 100 mm SL100 150 mm SL150 diameter in the ceiling or wall where the extractor is to be installed Remove the front cover A by removing screw SL150 only and pressing the catch 1 with the tip of a screwdriver until it is freed and then pulling it forward Place the exhaust conduit D in the hole in the ceiling or wall for exhaust of the air Fix the base of the housing B in place using the plugs and screws provided It may also be fixed to the interior of the ceiling using the 2 quickfit Loosen the screws 4 until the wedges 5 are fully concealed in the housings 6 and can be easily introduced inside the pipe Tighten the screws until the wedges 5 firmly fix the extractor to
4. rt stop pull switch 6 Fig P airconcent e cou The Ventilation Specialists Quick Order Hotline M Guaranteed Low Prices Ye L vI Huge Stock Available 0800 865 4567 M Xpelair Stockist or 0121 250 2186 Mon Fri 8 30am Wiring Diagrams SL100 SL150 A TSaMINALS N T a COUIET POLE IRSLATING BATE T SL100P SL150P TERMINES N RISE N M e GOWELE POLE SOLATING GATCE 4 TERMAL PULE CORD SWITCH AND MITOA CONMEC THOME SL100T SOT g mis i TO oue N l r Ms lie REQUIRED L DON ROLE EOLAING SitcH E TIMER oy Fig T A Pull switch circuit 6 30pm Sat amp Sun 11am 5pm airconcent cou The Ventilation Specialists Quick Order Hotline v Guaranteed Low Prices 0800 865 4567 vI Huge Stock Available vI Xpelair Stockist Mon Fri 8 30am 6 30pm Sat amp Sun 11am 5pm Do s and dont s e Do read all the instruction leaflet before commencing installation e Do install each fan with a double pole isolating switch e Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Guarantee Customers outside UK see international below e UK The fan is guaranteed against defects for 2 years from the date of purchase e Please keep your purchase receipt e If you have any problems contact Xpelair s Head Office at the address shown below Technical advice
5. the exhaust conduit Note All installations must be supervised by a qualified electrician Installations and wiring must conform to current IEE regulations UK local or appropriate regulations other countries Do not install the exhaust pipe D of the extractor unit to a chimney ventilation pipe or hot air conduit Before connecting the unit to pipelines consult the local municipal regulations regarding exhaust air and ask the permission of the person in charge of the building Make sure that the ventilation is appropriate especially when the extractor is used in conjunction with an appliance with a combustion chamber This extractor is designed for the ventilation of homes or similar premises Do not use in premises where the room temperature is above 40 C This extractor does not cause any interference in radio television sets C E E regulation No 89 336 ELECTRICAL CONNECTION The unit must be connected to a single phase mains power supply network at the voltage and frequency indicated on the rating plate of the extractor unit The electrical installation must include a double pole isolating switch with a distance between contacts of at least 3 mm Make the electrical connection by loosening the screw 2 until the cover 3 is free and connect the power supply cables to the connection strip E the blue cable to N and the brown cable to L Replace the cover 3 fixing it in place with the screw 2 and finally

Download Pdf Manuals

image

Related Search

Related Contents

Area en ligne  Sterling, PDAR Hochleistungsregler, technische  Philips Disney 2-in-1 Projector and night light 71769/28/16  loi de generalisation de la complementaire sante mode d`emploi  Volvo 240 & 260 series accessories & options brochure  isande gb  Onkyo SKS-HT690 Owner's Manual  

Copyright © All rights reserved.
Failed to retrieve file