1. STARTCO AC 700 CUA Firmware Upgrade Module TABLE OF CONTENTS SECTION PAGE 1 DAG OU COND s eraera anann nRa aa EE ERENT l 1 1 ATE Fle i EAEE SE E A IAE O ENEE A A AE TAE ATE 1 1 1 1 Firmware Upgrade Module uu cecsccssecssscesssecssscsesseceseeessecsseeesssseseesessaeens l 1 1 2 Communications Modules ccccccccssseesseceesseceessececsseeecsseecesseecesaeeceeaeeees 2 1 2 AC700 CUA FCAites ssccssastsinucescssiienernenic eaianiustianemnamineaniniaemauin 2 1 2 1 Firmware Upgrade Module uu ecccecsscsssseessecssseeesecsssecesseesseeceseeesseeesseees 2 1 2 2 Communications Modules ccccccessccesseceesseceesseeecssececeseecesseecssseeeseaeeeees 2 2 Installati n sennen e EE E a e aE 2 21 Firmware Upgrade Module Installation c cccecscecesceeneeceseceeseeceeeeesecesseesseeeeseeens 2 Zo Communications Module Installation cccccecssceesseceesseeeesseeeesseeeesseecesseeceesseeees 4 3 Technical Specifications ccccccccssccesscesssccessceescecsseeesseceeseeessecesseeessecesseeessecens 4 3 1 Firmware py rade Module sca soca cist veers cel eh cia eau uc sew aeeataccictehideseslaceadestustcunsdoetseaeebees 4 3 2 Communications Module seissen kiii NEEE EEEE EEE NE NEEE EEEE 4 4 Ordering TE PU AON se sabe scsctecdoczesesessictecsaszeelsvaecexstesepatacecisteseinwerdekecesteapelevaradieies 6 5 W ARE AN y ea eae cnta ce sg eases on ed eos a arene ws ev ects centres de Eos wna aves eo tect 7 Appendix A AC7
2. indications e Apply system power 3 TECHNICAL SPECIFICATIONS 3 1 FIRMWARE UPGRADE MODULE Isolation Device to Network VOILE s ierstenntrpravcnereonsteonninsis 2 500 Vrms Distanco 7 6 mm 0 3 Computer Interface Terminals TIA 232 through RJ45 Connector Mini USB Dimensions He Die 8 mm 0 3 NV ACUI r seas 43 mm 1 7 DC OU a 72 mm 2 8 Shipping Weight cceeeee 0 1 kg 0 3 Ib Environment Operating Temperature 40 to 60 C 40 to 140 F Storage Temperature 0 55 to 80 C 67 to 160 F Humidity ocassecetssercisevedesvnetsneedesonss 85 Non Condensing 3 2 COMMUNICATIONS MODULE Isolation Device to Network VOM SS iewaieincasinsadanmerwadsremsaaies 2 500 Vrms Distant eune aeaiieank 2 5 mm 0 08 Terminally cs ssvsscanncrsinensariaesciustesanacsinns Dependent upon communication standard Dimensions PLCC E EATE E EE 22 mm 0 9 NYE EA AE ATE 50 mm 2 0 DC superos 52 mm 2 0
3. 00 CUA Revision History cccccccccsccessccessecesseeessecessecesseeeseeeseeees 7 LIST OF FIGURES FIGURE PAGE l Firmware Upgrade Module AC700 CUA 00 Outline cece eceseseseeceeeesteeeenees 3 2 Communications Module AC700 CUA 03 Outline coe cceececcceeessseseeeeeeeees 3 3 Firmware Upgrade Module AC700 CUA O00 installed in an EL731 oe 5 4 Ethernet IP Communications Module AC700 CUA 03 installed in an EL731 5 5 Anybus Communications Module Installation 0 0 0 0 ceeceessecesceeesecseeecsseeeeeeeeseeens 6 DISCLAIMER Specifications are subject to change without notice Littelfuse Startco is not liable for contingent or consequential damages or for expenses sustained as a result of incorrect application incorrect adjustment or a malfunction 1 INTRODUCTION 1 1 GENERAL AC700 CUA is the base model number for the firmware upgrade module and communication modules which can be installed in various products available from Littelfuse 1 1 1 FIRMWARE UPGRADE MODULE The AC700 CUA 00 is used to upgrade compatible relay firmware and is field installable Detailed instructions are included in the help files of the SE Flash Firmware Upgrade Software Field upgrades allow for the addition of new or enhanced features and firmware maintenance The field upgrade module provides isolation between the unit under service and the computer running SE Flash de Littelfuse ze 4 012315 Page 6 STARTGCO AC700 CUA Firm
4. 1 Communications adapters can be ordered separately to field upgrade EL731 X0 X0O models Le Littelfuse rev 7 4 012315 Page 5 ie Littelfuse ze 1 4 012315 Page 2 STARTCO AC700 CUA Firmware Upgrade Module STARTCO AC700 CUA Firmware Upgrade Module 1 1 2 COMMUNICATIONS MODULES AC700 CUA serial communication modules can be factory installed or purchased separately An existing device not purchased with the communications option can be upgraded in the field 1 2 AC700 CUA FEATURES 1 2 1 FIRMWARE UPGRADE MODULE e RJ45 connector providing TIA232 communication CA 945 Interface Converter available separately e Mini USB Connector with included USB cable e 2 500 Vrms isolation e Field upgrade capability 1 2 2 COMMUNICATIONS MODULES e Isolated network interface on applicable modules On board network status indication according to network standard On board network connectors according to network standard Compact size 52 x 50 mm 2 x 2 Pre compliance tested for CE UL Compliant documented by UL in file E214107 2 INSTALLATION NOTE Before performing service on the device remove supply and control voltage 2 1 FIRMWARE UPGRADE MODULE INSTALLATION e Remove system and control voltage from the device e Remove the access panel from device to be upgraded See Fig 3 e Slide module into opening such that the rails on the circuit board slot align with the sides of the firmware upgrade module e Apply pressure to ensure p
5. Le Littelfuse rev 7 4 012315 Page 7 STARTCO AC700 CUA Firmware Upgrade Module 5 WARRANTY The AC700 CUA Communications amp Firmware Upgrade Modules are warranted to be free from defects in material and workmanship for a period of five years from the date of purchase Littelfuse Startco will at Littelfuse Startco s option repair replace or refund the original purchase price of an AC700 CUA that is determined by Littelfuse Startco to be defective if it is returned to the factory freight prepaid within the warranty period This warranty does not apply to repairs required as a result of misuse negligence an accident improper installation tampering or insufficient care Littelfuse Startco does not warrant products repaired or modified by non Littelfuse Startco personnel APPENDIX A AC700 CUA REVISION HISTORY MANUAL RELEASE MANUAL DATE REVISION January 23 2015 1 A 012315 MANUAL REVISION HISTORY REVISION 1 A 012315 SECTION 2 Updated installation instructions SECTION 4 Ordering information updated APPENDIX A Revision history added WA Littelfuse STARTCO 3714 Kinnear Place Saskatoon SK Canada S7P0A6 Ph 306 373 5505 Fx 306 374 2245 www littelfuse com relayscontrols AC700 CUA MANUAL COMMUNICATIONS amp FIRMWARE UPGRADE MODULES REVISION 1 A 012315 Copyright 2015 by Littelfuse Startco All rights reserved Document Number PM 1008 EN Printed in Canada 4L Littelfuse rev 1 4 012315 Page I
6. roper connection e Install SE Flash before connecting to the Firmware Upgrade Module e Connect either a TIA 232 or mini USB communications cable between the _ module and a computer FIGURE 4 Ethernet IP Communications Module AC700 CUA 03 installed in an e Follow the SE Flash help instructions for the product to be upgraded and EL731 apply system power Le Littelfuse rev 7 4 012315 Page 3 STARTCO AC700 CUA Firmware Upgrade Module NOTES 1 DIMENSIONS IN MILLIMETRES INCHES FIGURE 1 Firmware Upgrade Module AC700 CUA 00 Outline ajogojoge ollollofoljo NOTES aa ae 1 DIMENSIONS IN MILLIMETRES INCHES FIGURE 2 Communications Module AC700 CUA 03 Outline Le Littelfuse rev 7 4 012315 Page 4 STARTCO AC 700 CUA Firmware Upgrade Module 2 2 COMMUNICATIONS MODULE INSTALLATION e Remove system and control voltage from the device e Remove the access panel from device to be upgraded See Fig 3 e Slide module into opening such that the rails on the circuit board slot align with the sides of the communication module See Figs 4 and 5 e Apply pressure to ensure proper connection while aligning clips to circuit board e Tighten the installation screws using a Torx screwdriver size 8 T8 e Connect the communications cable as required by the network interface e See the upgraded device s manual for instructions on how to enable the communications module and definitions of the LED
7. ware Upgrade Module FASTENING REMOVAL 1 THE RECOMMENDED TERMINALTIGHTENING TORQUE IS 0 25 nM 2 WHEN FASTENINGTHE MODULE INTHE END PRODUCT MAKE SURE THAT THE ANYBUS MODULE IS PROPERLY ALIGNED INTO THE COMPACTFLASH SOCKET PRIORTO APPLYING ANY FORCE ROUGH HANDLING AND OR EXCESSIVE FORCE IN COMBINATIN WITH MISALIGNMENT MAY CAUSE MECHANICAL DAMAGE TO THE ANYBUS COMPACTCOM MODULE AND ORTHE END PRODUCT FIGURE 5 Anybus Communications Module Installation Shipping Weight cceeeeees 0 1 kg 0 3 Ib Environment Operating Temperature 40 to 60 C 40 to 140 F Storage Temperature 0 40 to 85 C 67 to 160 F PHU GICY cscee cccxscecsascrersvasesccnesteas 85 Non Condensing Shock and Vibration Shock TCS bssescecevenseuscuneiensineaseabensis Operating IEC 68 2 27 half sine 30 g 11 ms 3 positive and 3 negative shocks in each of three mutually perpendicular directions Shock Test xtscassscestenassesmenvaceaetes Operating IEC 68 2 27 half sine 50 g 11 ms 3 positive and 3 negative shocks in each of three mutually perpendicular directions Sinusodial Test cee ceeeeeseeeeee Operating IEC 68 2 6 10 500 Hz 0 35 mm 5 g 1 oct min 10 double sweep in each of three mutually perpendicular directions 4 ORDERING INFORMATION AC700 CUA 0 Communications Upgrade Adapter Adapter Type 0 Firmware Upgrade Module 1 DeviceNet 2 Profibus 3 EtherNet IP 4 Modbus TCP NOTES