Liebert® IntelliSlot® Relay Card

image

Contents

1. On Battery 8 On Battery Closed if On Battery power Utility failure 9 On Battery Closed if not On Battery power Utility OK 10 Signal Ground Use for UPS Any Mode Shutdown 11 Signal Ground Use for UPS Any Mode Shutdown 12 UPS Any Mode Shutdown T s UES output Off when shorted 13 Summary Alarm Closed if no alarm conditions are present 14 Summary Alarm Closed if Summary Alarm occurs 15 Common Summary Alarm 16 On UPS Closed if On UPS inverter power 17 On Bypass Closed if On Bypass 18 Common On Bypass Jumper Setup 4 0 JUMPER SETUP The card has five jumpers P3 through P7 as shown in Figure 2 Each jumper connects two pins Figure 2 Jumper location and numbering Jumper P6 Jumper Jumper P4 Jumper P3 a ken ke mi Tas ie T n m Jumper P7 By default all five jumpers have shunts installed The two pins are shunted together to provide the functions shown in Table 2 allowing relay commons to be tied together NOTE The jumpers should be removed if there is any external volt age source that may intentionally or inadvertently be connected to the relay Removing the shunt from any two pins breaks the connection between the relay commons so they are not tied together Table2 Jumper connections Jumper Relay P6 On Battery P5 UPS Fault P4 Low Battery P3 On Bypass P7 Summary Alarm Jumper Setup Ensuring The High Avail
2. Embedded Computing Embedded Power Monitoring EmersonNetworkPower com Outside Plant Power Switching amp Controls Precision Cooling Racks amp Integrated Cabinets Services Surge Protection Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2010 Emerson Electric Co
3. 9 connector and will conserve battery power after the workstation shutdown is completed The Liebert IntelliSlot Relay Card is rated for 24VAC VDC at 1A Inspecting Shipment on Receipt Upon accepting shipment inspect the packaging and product for any damaged or missing parts If any damage is observed report it to the shipping company and your local Emerson Network Power representative If any components are missing contact your local representative for replacement Items included with the shipment are Liebert IntelliSlot Relay Card protected by an anti static bag User manual Installation 2 0 INSTALLATION Make sure you have the following parts and tools before you begin Required Parts and Tools Liebert IntelliSlot Relay Card provided 2 medium Phillips or small flathead screwdriver Instructions 1 Turning off the unit prior to installation is suggested although not required 2 Locate the Liebert IntelliSlot port which is on the rear of some units as shown in the examples below Refer to the unit s user manual for port location and orientation IS RELAY Tr Ed y 1 PRESS TORESET Liebert IntelliSlot al Relay Card Remove screws 3 Remove the two retaining screws from the Liebert IntelliSlot port cover plate on the unit Save the screws for reassembly in Step 5 4 As you insert the card make sure the holes are aligned with those on the UPS Initially the card sho
4. Monitoring For Business Critical Continuity Liebert IntelliSlot Relay Card User Manual IS RELAY EMERSON TABLE OF CONTENTS 1 0 INTRODUCTION kk kk kk kk kk kk a hh hh hn Inspecting Shipment on Receipt KK KK RR KK KK 2 0 INSTALLATIONS y acu kk kk kk kk kk kk a a a a a a a kk a ata ta d Required Parts and Tools 0 cece RR RR EK KK KK Instructions u dee ae HH Ba ee ee ba lan 3 0 PIN CONFIGURATION kk kk ak kak Rh nnn 4 0 JUMPER SETUP a 55x2 sa a Figures Figure 1 Pin location and numbering 2000005 Figure 2 Jumper location and numbering Lille Tables Table 1 Relay card pin configuration RR RR Table 2 Jumper connections KK RR RR RR RR RR KK Introduction 1 0 INTRODUCTION The Liebert IntelliSlot Relay Card IS RELAY provides contact closure for remote monitoring of alarm conditions in your Liebert unit The card is easy to install and integrates with other relay contact monitoring systems This advanced power management device is designed to function in units with a Liebert IntelliSlot port Some examples are Liebert Nfinity Liebert NX Liebert UPStation GXT3 Visit the Liebert Web site at www liebert com for the current list of supported products On supported units the inverter shut off command can be controlled from the computer directly connected to the UPS via the factory installed DB
5. ability Of Mission Critical Data And Applications Technical Support Service Web Site www liebert com Monitoring 800 222 5877 monitoring emersonnetworkpower com Outside the US 614 841 6755 Single Phase UPS 800 222 5877 upstech emersonnetworkpower com Outside the US 614 841 6755 Three Phase UPS 800 543 2378 powertech emersonnetworkpower com Environmental Systems 800 543 2778 Outside the United States 614 888 0246 Locations United States 1050 Dearborn Drive P O Box 29186 Columbus OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD Italy 39 0499719111 Fax 39 049 5841 257 Asia 7 F Dah Sing Financial Centre 108 Gloucester Road Wanchai Hong Kong 852 2572220 Fax 852 28029250 While every precaution has been taken to ensure the accuracy and completeness of this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2007 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners SL 23211_REV1_08 12 Emerson Network Power The global leader in enabling Business Critical Continuity AC Power Connectivity DC Power
6. uld slide in freely as you carefully align screw holes As you feel it click into place press firmly to ensure solid seating in the slot 5 Use the screwdriver to secure the Liebert IntelliSlot Relay Card to the UPS chassis with the two retaining screws removed in Step 3 Make sure the screws are snug not tight to avoid damage to the device Installation 6 Use these guidelines for terminal block specifications Acceptable Wire Size 24 16 AWG Wire Strip Length 0 24 0 28 in 6 7mm Proceed to the following sections 3 0 Pin Configuration to configure the terminal blocks 4 0 Jumper Setup to configure the jumpers Pin Configuration 3 0 PIN CONFIGURATION The card has two terminals blocks TB1 green numbered 1 9 and TB2 black 10 18 as shown in Figure 1 Figure 1 TB1 green Pin location and numbering IS RELAY LS TB2 black 10 Refer to your Liebert product user manual for the pin configuration for the terminal blocks The pin functions in Table 1 apply only to the Liebert units listed in Section 1 0 Introduction Table 1 Relay card pin configuration Pin Function Operation 1 Common Low Battery 2 Low Battery Closed if Low Battery point occurs 3 Low Battery Closed if battery is OK 4 Common UPS Fault 5 UPSFault Closed if UPS fault occurs 6 UPS Fault Closed if no UPS failure 7 Common