Home

Mixed Signal Oscilloscopes

image

Contents

1. 067 1686 xx Deskew and Calibration Fixture 196 3508 xx Digital Probe Leadset 8 channels 119 7465 xx TekVPI External Power Supply SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software Full Version TEK USB 488 GPIB to USB adapter ACD2000 Soft Transit Case and Front Protective Cover 200 5045 xx Front Protective Cover HCTEK4321 Hard Transit Case requires ACD2000 RMD2000 Rackmount Kit Does not include slide out rails Option Description Opt C3 Calibration Service 3 years Opt C5 Calibration Service 5 years Opt CA1 Provides a single calibration event or coverage for the designated calibration interval whichever comes first Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 years with Opt C3 Opt D5 Calibration Data Report 5 years with Opt C5 Opt R5 Repair Service 5 years including warranty 3 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms 4 Requires TekVPI external power adapter 119 7465 00 one per oscilloscope 5 Requires TPA BNC adapter 6 Probes terminate into 50 but oscilloscope will automatically adjust to account for 1 MQ input 7 Requires 50 Q feed through termination between the oscilloscope input and the BNC cable Warranty Three year warranty covering all parts and labor excluding probes Tektronix is regis
2. printing to all PictBridge compatible printers RJ 45 connector supports 10 100Base T requires DPO2CONN DB 15 female connector connect to show the oscilloscope display on an external monitor or projector requires DPO2CONN Front panel BNC connector Input Impedance 1 MQ 2 Max input 300 Vrus CAT II with peaks lt 450 V Front panel pins Amplitude 5 V Frequency 1 kHz Rear panel security slot connects to standard Kensington style lock Description 100 to 240 V 10 45 to 65 Hz 90 to 264 V 360 to 440 Hz 100 to 132 V 80 W maximum Output Voltage 12 V Output Current 5 A Power Consumption 50 W Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series Physical Characteristics Dimensions Height Width Depth Weight Net Shipping Rackmount Configuration Cooling Clearance Environmental Characteristic Temperature Operating Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Random Vibration Operating Nonoperating Regulatory Electromagnetic Compatibility Safety mm in 180 fal 377 14 9 134 5 0 kg Ib 3 6 7 9 6 2 13 7 4U 2 in 50 mm required on left side and rear of instrument Description 0 C to 50 C 40 C to 71 C High 30 C to 50 C 5 to 60 Relative Humidity Low 0 C to 30 C 5 to 95 Relative Humidity High 30 C to 55 C 5 to 60 Relative Humidity Low 0 C to 30 C 5 to 95 Relative Humi
3. and Cycle Area Isolate the specific occurrence within an acquisition to take measurements on using either the screen or waveform cursors Description Add subtract and multiply waveforms Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Software Product NI LabVIEW SignalExpress Tektronix Edition OpenChoice Desktop IVI Driver eScope Description A fully interactive measurement software environment optimized for the MSO DPO2000 Series enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard MSO DPO2000 Series support for acquiring controlling viewing and exporting your live signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities and is available for a 30 day trial period standard with each instrument Enables fast and easy communication between a Windows PC and the MSO DP02000 series Transfer and save settings waveforms measurements and screen images Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or f
4. diagnose problems in complex 1 Megapoint Record Length on All Channels designs To capture long windows of signal activity while maintaining 5 000 wim s Maximum Waveform Capture Rate fine timing resolution the MSO DPO2000 offers a deep record length of 1 Mpoints standard on all channels Suite of Advanced Triggers With Wave Inspector controls for rapid waveform navigation and Ease of Use Features automated serial and parallel bus analysis the MSO DPO2000 Wave Inspector Controls Provide Easy Navigation and Automated Oscilloscope Series from Tektronix provides the feature rich tools you need Search of Waveform Data to simplify and speed debug of your complex design FilterVu Variable Low pass Filter Allows for Removal of Unwanted Signal Noise while still Capturing High frequency Events 29 Automated Measurements and FFT Analysis for Simplified Waveform Analysis TekVPI Probe Interface Supports Active Differential and Current Probes for Automatic Scaling and Units 7 in 180 mm Widescreen TFT LCD Color Display Small Footprint and Lightweight Only 5 3 in 134 mm deep and 7 lb 14 oz 3 6 kg Tektronix Data Sheet Noise Filter Ott 1 89450MHa 40 0ns qm 620m4 Discover A waveform capture rate of 5 000 wfm s maximizes the probability of capturing elusive glitches and other infrequent events Comprehensive Features Speed Every Stage of Debug The MSO DPO2000 Series offers a robust
5. set of features to speed every stage of debugging your design from quickly discovering an anomaly and capturing it to searching your waveform record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem first you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools The MSO DPO2000 Series offers complete visualization of signals providing fast insight into the real operation of your device A waveform capture rate of 5 000 waveforms per second enables you to see glitches and other infrequent transients quickly revealing the true nature of device faults A digital phosphor display with intensity grading shows the history of a signal s activity by intensifying areas of the signal that occur more frequently providing a visual display of just how often anomalies occur Moise Filter Ott Trigger On ITH Ul iii H MUl Hi Iii 4 00ms Gis Start Bit eel Trigger Un Bus RS 230 Ts Start Sit Normal Capture Triggering on a specific transmit data packet going across an RS 232 bus A complete set of triggers including triggers for specific serial packet content ensures you quickly capture your event of interest Capture Discovering a device fault is only the first step Next you must capture the event of interest to identify root cause The MSO DPO2000
6. 02024 DPO2024 Characteristic Channel to Channel 100 ns Deskew Range Time base Accuracy 25 ppm Horizontal System Digital Channels All MSO2000 Models 1 GS s 1 ns resolution Characteristic Maximum Sample Rate when using any of channels D7 D0 Maximum Sample Rate when using any of channels D15 D8 Maximum Record Length 1 Mpoints all channels 500 MS s 2 ns resolution Minimum Detectable 5 ns Pulse Width Channel to Channel 2 ns typical Skew Trigger System Characteristic Main Trigger Modes Trigger Coupling Trigger Holdoff Range Trigger Signal Frequency Counter Trigger Modes Mode Edge Pulse Width Runt Logic Setup and Hold Rise Fall Time Video I2C optional SPI optional CAN optional RS 232 422 485 UART optional LIN optional Parallel available on MSO models only Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series Trigger Sensitivity Description Characteristic Description Auto Normal and Single Internal DC Coupled 0 4 divisions from DC to 50 MHz DC HF reject attenuates gt 85 kHz LF reject a rine eels ee attenuates lt 65 kHz noise reject reduces sensitivity External 200 mV from DC to 100 MHz 1X attenuation Hn sE Auxiliary Input Trigger Level Range Provides a higher accuracy means of identifying Ig g the frequency of trigger signals Trigger Signal Characteristic Description Frequency counter resolution is 6 digits Any Channel
7. 4 92 divisions from center of screen External 6 25 V 1X attenuation Auxiliary Input 12 5 V 10X attenuation Description Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Trigger on width of positive or negative pulses that are gt lt or a specified period of time Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for all analog and digital input channels defined as High Low or Don t Care Trigger on violations of both setup time and hold time between clock and data present on any of the input channels Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Trigger on line number all lines odd even or all fields on NTSC PAL and SECAM video signals Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on 12C buses up to 3 4 Mb s Trigger on SS MOSI MISO or MOSI and MISO on SPI buses up to 10 0 Mb s Trigger on Start of Frame Frame Type data remote error overload Identifier standard or extended Data Identifier and Data End of Frame Missing AC
8. C Tek MSO2024 OpenChoice Desktop ior Am Screen man Waveform Get amp Send Ta T Capture 427 07 S DFS ee Capture Settings Preferences Select Instrument MSO02024 i Noise Filter Off Get Screen FY a wa Open Save As nm 4 00ms CO 3 47 rial Test Station 1 Tek MSO2024 DAC Copy to Clipboard a Modify Note Tektronix OpenChoice Desktop software enables seamless connection between the oscilloscope and your PC NI LabVIEW SignalExpress Tektronix Edition LE enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming The optional Professional Version offers over 200 built in functions that provide additional signal processing advanced analysis sweeping limit testing and user defined step capabilities For simple tasks the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB GPIB or LAN for transferring settings waveforms and screen images Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 9 TestEquipmentDepot com Data Sheet Characteristics Vertical System Analog Channels Characteristic Input Channels Analog Bandwidth 3 dB 1 Calculated Rise Time Hardware Bandwidth Limits Input Coupling Input Impedance Input Sensitivity Range Vertical Resoluti
9. K or Bit Stuffing Error on CAN signals up to 1 Mb s Data can be further specified to trigger on lt lt gt 2 or a specific data value User adjustable sample point is set to 50 by default Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error Trigger on Sync Identifier Data Identifier and Data Wakeup Frame Sleep Frame Errors such as Sync Parity or Checksum Errors Trigger on a parallel bus data value 11 Data Sheet Acquisition Modes Mode Sample Peak Detect Averaging Roll Description Acquire sampled values Captures glitches as narrow as 3 5 ns at all sweep speeds From 2 to 512 waveforms included in average Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms div Waveform Measurements Measurement Cursors Automatic Measurements Gating Waveform Math Characteristic Arithmetic FFT Description Waveform and Screen 29 of which up to four can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area
10. Series provides a complete set of triggers including runt logic pulse width glitch setup hold violation serial packet and parallel data to help quickly find your event With up to a 1 Mpoint record length you can capture many events of interest even thousands of serial packets in a single acquisition for further analysis while maintaining high resolution to zoom in on fine signal details From triggering on specific packet content to automatic decode in multiple data formats the MSO DPO2000 Series provides integrated support for a broad range of serial buses 12C SPI CAN LIN and RS 232 422 485 UART The ability to decode up to two serial and or parallel buses simultaneously means you gain insight into system level problems quickly To further help troubleshoot system level interactions in complex embedded systems the MSO2000 Series offers 16 digital channels in addition to its analog channels Since the digital channels are fully integrated into the oscilloscope you can trigger across all input channels automatically time correlating all analog digital and serial signals Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series _Prevu hi 10 0rms Moise Filter Off AE SO Data 00 A 50 Data 10 TS ia CK Search 2C decode showing results from a Wave Inspector search for Address value 50 Wave Inspector controls provide unprecedented efficiency in viewing and navigating waveform data Se
11. Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 1 800 517 8431 Mixed Signal Oscilloscopes MS0O2000 Series DPO2000 Series Data Sheet Connectivity USB 2 0 Host Port on the Front Panel for Quick and Easy Data Storage USB 2 0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge compatible Printer Optional 10 100 Ethernet Port for Network Connection and Video Out ee eee ps cme Port to Export the Oscilloscope Display to a Monitor or Projector ee rigor CUETO DA a N 12C data WA UE UU Noise Filter Off i Optional Serial Triggering and Analysis Automated Serial Triggering Decode and Search Options for 12C SPI CAN LIN and RS 232 422 485 UART fo a Mixed Signal Design and Analysis MSO Series Automated Triggering Decode and Search on Parallel Buses Features amp Benefits Multichannel Setup and Hold Triggering Key Performance Specifications Feature rich Tools for Debugging Mixed 200 100 MHz Bandwidth Models Signal Designs 2and 4 Analog Channel Models Offering up to 200 MHz bandwidth and 1 GS s sample rate the 16 Digital Channels MSO Series MSO DPO2000 Mixed Signal Oscilloscope Series delivers advanced debug a 1 GS s Sample Rate on All Channels features at an entry level price with up to 20 channels for analyzing analog and digital signals you can quickly find and
12. al Opt L1 French manual Opt L2 Italian manual Opt L3 German manual Opt L4 Spanish manual Opt L5 Japanese manual Opt L6 Portuguese manual Opt L7 Simplified Chinese manual Opt L8 Traditional Chinese manual Opt L9 Korean manual Opt L10 Russian manual Opt L99 No manual 2 Language options include translated front panel overlay for the selected language s Service Options 3 Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series Recommended Probes Probe Description TAP1500 4 1 5 GHz TekVPI single ended active probe TDP0500 4 6 500 MHz TekVPI 42 V differential probe TCP0030 4 120 MHz TekVPI 30 Ampere AC DC current probe TCP0150 4 20 MHz TekVPI 150 Ampere AC DC current probe TCPA300 400 7 Current measurement system amplifiers TCP305 DC to 50 MHz 50 Ampere current probe for use with TCPA300 TCP404XL DC to 2 MHz 500 Ampere current probe for use with TCPA400 P5100A 2 5 kV 500 MHz 100X high voltage passive probe TMDP0200 4 750 V 200 MHz high voltage differential probe THDP0200 4 1 5 kV 200 MHz high voltage differential probe THDP0100 4 6 kV 100 MHz high voltage differential probe ADA400A 4 5 100X 10X 1X 0 1X high gain differential amplifier Recommended Accessories Accessory Description DPO2CONN Adds Ethernet 10 100Base T and Video Out Port 071 2331 xx Service Manual English only TPA BNC 4 TekVPI to TekProbe BNC adapter TEK DPG 4 TekVPI Deskew Pulse Generator Signal Source
13. arch events found 115 Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing to a million data points locating your event can mean scrolling through thousands of screens of signal activity The MSO DPO2000 Series offers the industry s most comprehensive search and waveform navigation with its innovative Wave Inspector controls These controls speed panning and zooming through your record With a unique force feedback system you can move from one end of your record to the other in just seconds User marks allow you to mark any location that you may want to reference later for further investigation Or automatically search your record for criteria you define Wave Inspector will instantly search your entire record including analog digital and serial bus data Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 Moise Filter Ott 13 3337 MHz Analyze FFT analysis of a pulsed signal A comprehensive set of integrated analysis tools speeds verification of your design s performance Analyze Verifying that your prototype s performance matches simulations and meets the project s design goals requires analyzing its behavior Tasks can range from simple checks of rise times and puls
14. dity 3 000 meters 9 843 feet 12 000 meters 39 370 feet 0 31 Grus from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total 2 46 Gens from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total EC Council Directive 2004 108 EC UL61010 1 2004 CAN CSA C22 2 No 61010 1 04 EN61010 1 2001 Complies with the Low Voltage Directive 2004 108 EC for Product Safety 13 Data Sheet Ordering Information DPO2000 Models Product DPO2012 DPO2014 DPO2024 MSO2000 Models Product MSO2012 MSO2014 MSO2024 All Models Include One TPP0200 200 MHz 10X Passive Probe per Analog Channel User Manual and Translated Front panel Overlay Documentation CD 063 4118 xx OpenChoice Desktop Software NI LabVIEW SignalExpress Tektronix Edition LE Software Calibration certificates document measurement traceability to National Metrology Institute s and IS09001 Quality System Registration Power Cord and a three year warranty Please specify power plug and Description 100 MHz 1 GS s 1M record length 2 channel digital phosphor oscilloscope 100 MHz 1 GS s 1M record length 4 channel digital phosphor oscilloscope 200 MHz 1 GS s 1M record length 4 channel digital phosphor oscilloscope Description 100 MHz 1 GS s 1M record length 2 16 channel mixed signal oscilloscope 100 MHz 1 GS s 1M record length 4 16 channel mixed signal oscilloscope 200 MHz 1 GS s 1M record length 4 16 channel mi
15. e infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points that occur more frequently are intensified This quickly highlights the events Moise Filter 01 Thresholds Linita C harnrel be Family value l l l l Jla Dus Fesolution 1 ns With the color coded digital waveform display groups are created by simply placing digital channels together on the screen allowing the digital channels to be moved as a group You can set threshold values for each pod of eight channels enabling support for up to two different logic families that over time occur more often or in the case of infrequent anomalies occur less often With the MSO DPO2000 Series you can choose infinite persistence or variable persistence determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Mixed Signal Design and Analysis MSO Series The MS02000 Series Mixed Signal Oscilloscopes provide 16 digital channels These channels are tightly integrated into the oscilloscope s user interface simplifying operation and making it possible to solve mixed signal issues easily Color coded Digital Waveform Display The MSO2000 Series has redefined the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining
16. e widths to sophisticated power loss analysis and investigation of noise sources The MSO DPO2000 Series offers a comprehensive set of integrated analysis tools including waveform and screen based cursors 29 automated measurements and FFT analysis Specialized application support for serial bus analysis is also available For extended analysis National Instrument s LabVIEW SignalExpress Tektronix Edition provides over 200 built in functions including time and frequency domain analysis limit testing data logging and customizable reports TestEquipmentDepot com Data Sheet Wave Inspector controls provide unprecedented efficiency in viewing navigating and analyzing waveform data Zip through your 1 Mpoint record by turning the outer pan control 1 Get from the beginning to end in seconds See something of interest and want to see more details Just turn the inner zoom control 2 Wave Inspector Navigation and Search A 1 Mpoint record length represents thousands of screens of information The MSO DP02000 Series enables you to find your event in seconds with Wave Inspector the industry s best tool for navigation and search Wave Inspector offers the following innovative controls Zoom Pan A dedicated two tier front panel control provides intuitive control of both zooming and panning The inner control adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progressively higher z
17. if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display The MSO2000 Series has color coded digital traces displaying ones in green and zeros in blue Data Sheet Moise Filter Ott 4 00ns EEE 3 33926MHz White edges indicate additional information is available by acquiring at a higher sample rate The P6316 MSO probe offers two eight channel pods to simplify connecting to your device The multiple transition detection hardware of the MSO2000 Series will show you a white edge on the display when the system detects multiple transitions This acts as a visual reminder that increasing the sample rate on the next acquisition will reveal higher frequency information than your previous settings could acquire The MSO2000 Series simplifies channel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard By simply placing digital waveforms next to each other they form a group Once a group is formed you can position all the channels contained in that group collectively This greatly reduces the normal setup time associated with positioning channels individually P6316 MSO Probe This unique probe design offers two eight channel pods simplifying the process of connecting to the device under test When connecting to square pins the P6316 can connect directly to 8x2 square pin headers spaced on tenth inch centers When more attach
18. in a tabular view much like you would see in a software listing Packets are time stamped and listed consecutively with columns for each component Address Data etc Search Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past users had to manually scroll through the waveform counting and converting bits and looking for what caused the event With the MSO DPO2000 Series you can have the oscilloscope automatically search through the acquired data for user defined criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks is as simple as pressing the Previous lt and Next buttons on the front panel Data Sheet FilterVu IRE 50 Oata 1 Data 20 Data 22 Data 24 0 cet HMA AAA caer WLS LU data TOSI Egg equa The MSO DPO2000 is designed to make your work easier The bright widescreen display shows a long time window Dedicated front panel controls simplify operation A USB host port on the front panel allows you to easily transfer screenshots instrument settings and waveform data to a memory stick Designed to Make Your Work Easier Bright Widescreen Display The MSO DPO2000 Series features a 7 inch 180 mm widescreen TFT LCD display for seeing intricate signal details Dedicated Front panel C
19. lar serial interfaces such as 2C SPI CAN LIN and RS 232 422 485 UART Bus Display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying subpacket components such as address data identifier CRC etc Bus Decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is a 1 or a0 combine bits into bytes and determine the hex value Let the oscilloscope do it for you Once you ve set up a bus the Time Identifier DLC Data CAC Missing Ack Zen Te 44 35ms TFFFFFFF Og FFFFFFFFFFFFFFFF 166 D 33 40ms 100 0 2004 33 25ms 101 2 1103 2620 mi 39 16m5 TOOO0007 5 1122 3344 55 BABS a 36 94ms 12345678 1122 3344 5566 Fraa dC2 30 39m5 Sile 4 4269 6C6C fr 323m5 1597EEB2 AEAF FRR 0272 OF66 2180 3r dEms 92r Ba 1 11 FPO 3r alms 140014 3 1122 33 SEDC 3r 6 ms 160016 a 1122 3344 55 3911 3r ams 16181615 F FIF2 F3F4 FSFE FT oF dB selects an event Event table showing decoded Identifier DLC DATA and CRC for every CAN packet in a long acquisition MSO DPO2000 Series will decode each packet on the bus and display the value in hex binary decimal LIN only or ASCII RS 232 422 485 UART only in the bus waveform Event Table In addition to seeing decoded packet data on the bus waveform itself you can view all captured packets
20. ment flexibility is required you can use the included flying lead sets and grabbers to clip onto surface mount devices or test points The P6316 offers outstanding electrical characteristics applying only 8 pF of capacitive loading with 101 kQ input impedance a UKH2 Moise Fieri cio 1 50kHz E EET Output of DAC Signal Notice how FilterVu clearly shows the noise free steps of the DAC in the foreground trace yellow which has removed all frequencies above 5 5 kHz FilterVu also captures and displays high frequency glitches up to the full bandwidth of the oscilloscope in the background trace orange FilterVu Variable Low pass Filter Tired of being limited to a 20 MHz bandwidth filter in your oscilloscope Simply turn on FilterVu and adjust the variable low pass noise filter Unlike other variable low pass filters FilterVu filters out the unwanted noise from your signal while still capturing glitches and other signal details up to the full bandwidth of the oscilloscope It does this by showing two waveforms a waveform that can be filtered foreground waveform and a glitch capture waveform background waveform The filtered waveform uses a variable low pass filter to block out noise yielding a cleaner waveform to more precisely locate signal edges and amplitude levels The result is improved confidence in you cursor measurements and cleaner documentation of important signal attributes When the noise filter is adj
21. on Maximum Input Voltage 1 MQ DC Gain Accuracy with offset set to 0 V Channel to Channel Isolation MSO2012 MSO2014 MSO2024 DPO2012 DPO2014 DPO2024 2 4 4 100 MHz 100 MHz 200 MHz 3 5 ns 3 5 ns 2 1 ns 20 MHz AC DC GND 1 MQ 2 11 5 pF 2 pF 2 mV div to 5 V div 8 bits 300 Vams with peaks lt 450 V 3 for 10 mV div to 5 V div 4 for 2 mV div to 5 mV div 2100 1 at lt 100 MHz 100 1 at lt 200 MHz Any Two Channels at Equal Vertical Scale 1 Bandwidth is 20 MHz at 2 mV div all models Offset Range Range 1MQ 2 mV div to 200 mV div 1V gt 200 mV div to 5 V div 25 V Vertical System Digital Channels All MSO2000 Models 16 Digital D15 to DO Thresholds Threshold per set of 8 channels Threshold Selections TTL CMOS ECL PECL User Defined User defined Threshold 20 V Range Maximum Input Voltage 40 V Threshold Accuracy 100 mV 3 of threshold setting Maximum Input Dynamic 80 Vp p threshold setting dependent Range Characteristic Input Channels Minimum Voltage Swing 500 MV 4 x Input Impedance 101 kQ Probe Loading 8 pF Vertical Resolution 1 bit Horizontal System Analog Channels MS0O2012 2014 DPO2012 2014 Maximum Sample Rate 1 GS s all channels Maximum Record Length 1 Mpoints all channels Maximum Duration of 1 ms Time Captured at Highest Sample Rate all channels Time base Range s div 4 ns to 100 s 2 ns to 100 s Time base Delay Time 10 divisions to 5000 s Range MS
22. ontrolled remotely through USB GPIB or Ethernet enabling more versatile solutions in ATE environments Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series Untitled 1 LabVIEW SignalExpress KES Fie Edit View Tools AddStep Window TekDPO MSO2000 Help Q Addstep Stop RunOnce Record ResetAl G E gp ees S e E ever U Autoset BP Save Image E Sync to Scope amp B Scope Utilities sA A Dok 7 Show Help M Show entire waveform J a DPO2012 CH1 DPO2012 CH2 7 I gt FB DPO2012 CH1 I gt FB DPO2012 CH2 SignalExpress controls instrument a Vertical Horizontal Trigger Measurements VISAResource Execution Control Scale s div Acquisition mode 400n s Sample Position s 0 tg Start OR u E 6 Q untitled 1 O 2Microsoft c NISETE doc NI LabVIEW SignalExpress Tektronix Edition is a fully interactive measurement acquisition and analysis software developed jointly with National Instruments and optimized for the MSO DPO Series Extended Analysis Acquiring data and measurements from the MSO DPO2000 Series is as simple as connecting a USB cable from the oscilloscope to your PC Key software applications NI LabVIEW SignalExpress Tektronix Edition LE OpenChoice Desktop and Microsoft Excel and Word toolbars are included standard with each oscilloscope to enable fast and easy direct communication with your Windows P
23. ontrols Per channel vertical controls provide simple and intuitive operation No longer do you need to share one set of vertical controls across all four channels Connectivity A USB host port on the front panel enables easy transfer of screenshots instrument settings and waveform data to a USB thumb drive The rear panel contains a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard The USB device port can also be used to print directly to a PictBridge compatible printer An optional 10 100 Ethernet port enables easy connection to networks and an optional Video Out port allows the oscilloscope display to be exported to an external monitor or projector Compact Form Factor A compact portable form factor allows the MSO DPO2000 Series to be easily moved between labs and with a depth of just 5 3 inches 134 mm it saves you valuable space on your test bench The MSO DPO2000 Series compact form factor frees up valuable space on your bench or desktop TekVPI probe interface simplifies connecting your probes to the oscilloscope TekVPI Probe Interface The TekVPI probe interface sets the standard for ease of use in probing TekVPI probes feature status indicators and controls as well as a probe menu button right on the comp box itself This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe TekVPI probes can be c
24. oom factors while turning it counterclockwise results in lower zoom factors and eventually turning zoom off No longer do you need to navigate through multiple menus to adjust your zoom view The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in The outer control also utilizes force feedback to determine how fast to pan on the waveform The farther you turn the outer control the faster the zoom box moves Pan direction is changed by simply turning the control the other way Play Pause A dedicated Play Pause front panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan control Once again turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way M i0 ms Zoom Factor S00 Noise Filter Dl CaN Ta Ta F 7 a Identifier selects a binary or hex digit sets its value i I La O COC U od Lu a Dd H DGI H DEC HBC CRC T744 Search events found 10 20 0 us lem 13564 TERTA ldentitier m o eu ma ee e Search step 1 You define what you would like to find M 10 ms Zoom Factor 500 4 Moise Filter Off ld 515 d H DO d H DESH OGC H OGC CRC TTAA Search events found 10 li 20 0 us Search step 2 Wave Inspector automatically searches through the rec
25. ord and marks each event with a hollow white triangle You can then use the Previous and Next buttons to jump from one event to the next User Marks Press the Set Mark front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search Marks The Search button allows you to automatically search through your long acquisition looking for user defined events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width glitch runt logic setup and hold rise fall time parallel bus and l2C SPI CAN LIN and RS 232 422 485 UART packet content Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series Noise Filter Off 4 00ns ebun oO Ba Digital phosphor technology enables a 5 000 wfm s waveform capture rate and real time intensity grading on the MSO DPO2000 Series Worse Filter UTT 400ms _FEE Te The MSO Series provides 16 integrated digital channels enabling you to view and analyze time correlated analog and digital signals Digital Phosphor Technology The MSO DPO2000 Series digital phosphor technology provides you with fast insight into the real operation of your device Its waveform capture rate of 5 000 wim s gives you a high probability of quickly seeing th
26. tered to ISO 9001 and ISO 14001 by SRI Quality System Registrar Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Grip Standard Codes and Formats Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 15 TestEquipmentDepot com
27. urther analysis Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB Enables control of the MSO DPO2000 Series over a network connection through a standard web browser Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com Display Characteristics Characteristic Display Type Display Resolution Waveform Styles Graticules Format Maximum Waveform Capture Rate Input Output Ports Port USB 2 0 High speed Host Port USB 2 0 High speed Device Port LAN Port Video Out Port Auxiliary Input Probe Compensator Output Kensington Style Lock Power Source Characteristic Power Source Voltage Power Source Frequency Power Consumption Optional TekVPI External Power Supply 119 7465 xx Description 7 in 180 mm liquid crystal TFT color display 480 horizontal x 234 vertical pixels WQVGA Vectors Dots In Video Trigger mode Variable Persistence Infinite Persistence Full Grid Cross Hair Frame YT and XY Up to 5 000 wfm s Description Supports USB mass storage devices and keyboards One port available on front panel Rear panel connector allows for communication control of oscilloscope through USBTMC or GPIB with a TEK USB 488 and direct
28. usted to the lowest available noise cutoff frequency no more than 1 of high frequency content that could cause the oscilloscope to alias will pass through the filter The glitch capture waveform shows signal details up to the full bandwidth of the oscilloscope The oscilloscope captures pulses as narrow as 5 ns using peak detect min max sampling protecting you from missing unexpected glitches or other high frequency events FilterVu is ideal for repetitive nonrepetitive and single shot events 6 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com Mixed Signal Oscilloscopes MSO2000 Series DPO2000 Series Addr A 50 Data 14 Data 16 jaos anina Address SSCS Triggering on a specific data packet going across an 2C bus The yellow waveform is clock and the blue waveform is data A bus waveform provides decoded packet content including Start Address Read Write Data and Stop Serial Triggering and Analysis Optional On a serial bus a single signal often includes address control data and Clock information This can make isolating events of interest difficult The MSO DPO2000 Series offers a robust set of tools for debugging serial buses with automatic trigger decode and search for 12C SPI CAN LIN and RS 232 422 485 UART Serial Triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popu
29. xed signal oscilloscope manual version when ordering MSO Models also Include One P6316 16 channel logic probe and accessory kit and accessory bag 016 2008 xx Application Modules Modules Description DPO2ZAUTO Automotive Serial Triggering and Analysis Module DPO2COMP DPO2EMBD Enables triggering on packet level information on CAN bus and LIN bus as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Computer Serial Triggering and Analysis Module Enables triggering on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on I2C and SPI buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Only two wire SPI support available on DPO2012 MSO2012 models Instrument Options Power Plug Options Option Description Opt Ad North America Opt A1 Universal Euro Opt A2 United Kingdom Opt A3 Australia Opt Ad Switzerland Opt A6 Japan Opt A10 China Opt A11 India Opt A99 No power cord Language Options 2 Option Description Opt LO English manu