Home
Operating Manual for OPTOCORE DD32R-FX
Contents
1. Word clock Hardware standard BNC 75 Q Data rate Depending on selected sample rate Up to 192 kHz Impedance Output lt 5Q Input 750 Drive level Output 2 1 Vp Zero level Referring to GND 1 7V Sense level Input 2 400 MV pp Remote Conirol Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s SANE LAN Convention Audio TIA 568A B Optocore 200 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s Optical Connection Complies with 21 CFR 1040 10 and 1040 11 Power supply Type Mains voltage Frequency Power consumption Security classification Security regulations Mains connector Cooling Switch mode universal input 100 240 V 50 60 Hz Depending on device 32VA Max Class 1 basic insulation connected to the protective grounding conductor Harmonised European standard EN60065 acc to IEC 950 Passive via surface and ventilation slits on both sides DD32R FX 23 26 rev 2 3 OPTOCORE Dimensions and Weight Front panel width 483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight 2 7 kg 4 41 lbs Please note Modifications that serve the purpose of technical improvement may be carried out without prior notification DD32R FX 24 26 rev 2 3 OPTOCORE Warranty and Liability Summary of Warranty OPTOCORE DD32R FX de
2. Modifications which serve the purpose of technical improvement of the device may be carried out without prior notification Transport and Shipping Always ensure careful handling of the device The device should be transported and shipped in shock absorbing transport cases If these are not available we recommend well padded packaging such as the coated carton in which the device was delivered We strongly advise against the use of light weight flight cases without shock absorbing rack in rack mounting Environments This device can be used in E1 E2 E3 E4 or E5 environments as listed below according to the harmonised European standards EN55103 1 and EN55103 2 Electromagnetic compatibility Product family standard for audio video and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation openings Install the device in accordance with the operating manual Allow for sufficient space around the units at least 200 mm 7 87 free space behind the rear panel of the device and make sure to allow for air circulation near the ventilation openings on both sides of the device Keep the rear of the rack open during operation Do not operate the device cl
3. OPTOCORE devices contain no user serviceable components refer to qualified service personnel for repair or upgrade The warranty will be void if you tamper with internal components Please address any questions or inquiries to OPTOCORE or your distributor dealer For a full warranty conditions refer to the Warranty Card attached to every Optocore device with a first shipment How to Obtain Warranty Service When discovering a problem with an OPTOCORE device you should contact either Optocore directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to OPTOCORE OPTOCORE will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest authorised OPTOCORE dealer distributor The dealer distributor will make sure that the device is serviced according to the terms of warranty by OPTOCORE or an authorised service centre If the equipment needs to be returned directly to OPTOCORE first contact supportOoptocore com OPTOCORE requires the serial number of the equipment intended for return as well as a short description of the problem If possible you should also provide us a phone number where you can be reached during regular working hours To return a defective product please contact your distributor dealer Our web site http www optocore com provides a complete list
4. 7 8 9410 11 12113 14115 16 Le Channel EWE Ene GND PEEVES a D Sub 25 female eee Locking system acc to 4 40 UNC ae Ports 4 x RS485 sass Channel GND Mila sel Please assure correct polarity and at both sides devices when connecting 1 2 3 la external equipment to the RS485 ports Pin 5 per jodo De D Sub 9 female Locking system acc to 4 40 UNC SANE Synchronous Audio and Ethernet MAD In MADI Out In Out A device compatible with 10 100MB Fast Ethernet can be connected to a SANE port for Pin 8 5 6 2 Ethernet data communication E L 3 Pin out Optical Fibre Port Optocore LC connectors DD32R FX 21 26 rev 2 3 OPTOCORE pa XO Tx bridged Use standard RS232 cable male female to connect to PC Pee fe fe feels Lo EEN D Sub 9 female Locking system acc to 4 40 UNC USB Port cnamnet 488 GND VBUS Ei USB device connector DD32R FX 22 26 rev 2 3 OPTOCORE Technical Specifications AES Ports Convention ElA TIA 422 Channels AES EBU 4x8 Audio channels 4x16 Data rate Depending on selected sample rate Up to 30 Mbit s per channel Impedance Termination 120 O switchable gt 96 KQ Source lt 10 Q Multi drop feature Drive level Output 2 2 Vop Zero level Referring to GND 1 7V Sense level Input 2 400 MVpp CM voltage at bus terminals Referring to GND 7V 412V
5. Bus bi directional requires special firmware version or RS422 DMX and MIDI unidirectional The ports automatically sense whether they are sending or receiving control data The ports and their destinations are configured in the OPTOCORE CONTROL software Word Clock Devices with Optocore SANE modules are equipped with an internal high quality low jitter clock generator as well as Word Clock inputs and outputs Any device on the network can act as the master of the network and pass Word Clock to networked Optocore SANE devices The internal networked Word Clock is available at the Word Clock output connector of each device on the network to synchronize non networked devices In standalone network configurations external synchronization is not required The Word Clock input termination can be switched on using the OPTOCORE CONTROL software s Local Settings External termination is not required to avoid cable reflections Word Clock master negotiation after any Word Clock source failure is done automatically Video Ports A video in and output is integrated for the transmission of composite video signals Up to three video channels can be transported through the Optocore network depending on configuration Ethernet Ports DD32R FX supports Optocore and SANE Ethernet transport Two LAN ports interface with all other LAN and SANE LAN ports in the Optocore and SANE Network creating a large unmanaged virtual 100Mbit Ethernet switch DD32
6. DD32R FX and other Revolution FX devices to exchange audio channels Ethernet and Gain Control All parameters on the I O Module can be controlled and monitored with the same software application as all other Optocore devices OPTOCORE CONTROL software They allow for the distribution of various channels of I O at the different locations throughout your digital Optocore and or SANE network The Word Clock IN and OUT connections enable the synchronisation of the units to an external source and are used to pass the word clock from one unit to the next For stand alone applications the devices are equipped with an internal word clock generator The DD32R FX units can be operated and controlled via the OPTOCORE network with OPTOCORE CONTROL software without the need for any external data cable For control the USB RS232 or LAN ports on the front rear panels can be used All Optocore devices are designed and built using the latest programmable microprocessors and FPGA field programmable gate array logic circuitry This allows the devices internal logic to be updated in the field ensuring a continual state of the art device DD32R FX 10 26 rev 2 3 OPTOCORE Optocore devices and complete networks are configured and operated using the OPTOCORE CONTROL software The software provides access to all configuration parameters and controls needed to operate the system including naming channels setting gains and phantom power routing as well a
7. network is as follows Audi 256 Channels 48 KHz 1 Gbit network 768 Channels 48 kHz 2 Gbit network RS485 Data 32 Channels Video 3 CVBS Video Channels Ethernet 100 MBit Fast Ethernet If the network is used for the transport of Ethernet compatible data the capacity is reduced to one CVBS video channel plus 100 Mbps Fast Ethernet Please note Optocore R Series devices equipped with 2Gbit fibre transceivers are required for 2Gbit network operation SANE bandwidth allocation The standard bandwidth allocation of a SANE link is as follows Audio 64 Channels 48 KHz Ethernet 100 MBit Fast Ethernet DD32R FX 17 26 rev 2 3 OPTOCORE Connectors and Cables Optical Connection Multimode transceivers connected using a 50 um OMS fibre cable can be used for applications requiring cable lengths of up to 700 m worst case Single mode transceivers connected using a 9 um fibre cable can be used for applications requiring cable lengths of up to 70 km worst case The total optical loss should be less than 6dB between transceivers For portable applications such as touring and other temporary installations ruggedized HMA Expanded Beam Connectors mounted on 1 RU panels and portable cables on cable drums are available Please refer to the Product Brochure available at www optocore com Principal and Auxiliary Ports Each of the four channels requires a shielded twis
8. of time Important The switched mode power supplies operate at very high voltages Coming into contact with the power supplies can lead to considerable electric shock which may result in death Never disconnect the main plug by pulling the cable always pull the plug itself Power supply cords should be routed in such a way that they are not likely to be walked on crushed pinched or damaged in any other way Pay special attention to the plugs and the sockets of the device Important A damaged power cable must be replaced immediately The device must be grounded Disconnecting the ground is strictly prohibited Ensure that the device is always grounded using the power connector Do not cover the ground connection of the power connector with any kind of insulation material Fuse There is no fuse in the device The power supplies contain circuitry that protects the device from overload e Lightning For additional protection of this device during lightning storms or when it is left unattended and unused for a long period of time disconnect the power cord This will prevent damage to the device due to lightning and power line surges Disconnection from the mains power supply is only possible by disconnecting the power plug from the mains socket e Eye Safety This product is a Laser Class 1 product It complies with IEC 60825 1 FDA 21 CFR 1040 10 and 1040 11 e External objects and or liquids Never push ob
9. party Controleren ii ia 16 Optocore bandwidth alloCatiON ooooninccinnnninncnnnccnocccnnccnnornnnancnnrnn narran 17 SANE bandwidth alloCatiON oooonnnininnnnnnnnnnnccnnncconnccnncncnn nn cnnrn conc r cnn crac 17 Gonnectors and Cables cin e nee eines 18 Optical Connection iecere nea aaa iio 18 Principal and Auxiliary POTIS ciis aaaea aiaia ar ENEA AEEA EN 18 SANE Poli E E aida 18 USB CONNECHON ui a A dia 18 Word Clock Connection ccccccecceeeceeseeeeeneeeeeeeeeseeeseaeesaceesaeeesaeeseaeeeseeesaeesaaeeseaeesaaeeseaeeeaeeseaeesseeeseaeeenaees 18 Vid O CONMMECHION 5 coin a ida 18 Mains Connections iio 18 Hardware Connect ld idear 19 Example dro a ie i ee eee oa as 19 Example 2 cacao e iti Rie lain E Tine aie ee 20 Connection Tables ccoo diia 21 Technical Specitications tna ic 23 Dimensions and Welt o paar 24 Warranty and Liability ocurrida aa aii 25 SHIPPING CONIENIS srie ee nan leelo a tod 26 Company Inia ii A dh ledeAaeadeceeeuetes 26 DD32R FX 9 26 rev 2 3 OPTOCORE Device Description Congratulations on your purchase of a DD32R FX Digital I O Module for Optocore and SANE with video Ethernet and data interfaces The DD32R FX manual will quickly demonstrate its advantages and help to ease your day to day workload in a professional audio visual environment The DD32R FX is a digital I O unit and interface to the OPTOCORE and SANE DIGITAL NETWORK SYSTEM It offers four principal ports for connection and trans
10. DD32R OPTOCORE POWEI senate So Soe CE marinos O mes Gu t MADE orman OrTocore a Operating Manual for OPTOCORE DD32R FX AES EBU I O SANE VIDEO DATA MODULE WITH ETHERNET Optical Digital Network Device Copyright 2015 All rights reserved OPTOCORE GmbH Lohenstr 8 82166 Munich Gr felfing Germany DD32R FX Digital I O for Optocore and SANE Operating Manual Rev 2 3 Page intentionally left blank OPTOCORE Important Safety Instructions Please read this manual carefully Please keep this operating manual in a safe place Heed all warnings Follow all instructions This device may only be used in accordance to the information provided in this operating manual Ensure that all recommendations especially the safety recommendations as detailed in this operating manual are followed before and during the usage of the device Do not use this device near water for example in humid or damp rooms Clean only with a dry cloth Do not block or cover any ventilation slits Install the device in accordance with the operating manual Do not install or place the device near any heat source such as radiators power amplifiers or any other heat producing equipment Protect the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Never switch on power amplifiers before the complete system is stable and the level mete
11. OUTPUTS G OUTPUTS 1 16 33 40 1 8 33 40 1 8 X6R FX 16MI X6R TP 16MI X6R TP 8MI 8LO X6R TP 8Ml 8LO LINK 1 LINK 2 OUT IN OUT IN SANE 1 ES ES EE SANE 2 SANE 1 SANE 2 SANE 1 SANE 2 SANE 1 e ee ae IN OUT IN OUT LINK 1 LINK 2 gees DD32R FX CLOCK PRINCIPAL PORTS OUT A D RS485 5 A Se wee AMAS En A y AS 0 a Merc TRI A TRI A 2 e El e 2 EN E o a A AS OS 7 MY16 AE 1 MY16 AE 2 MY16 AE 3 IN 1 8 IN9 16 IN 17 24 IN 25 32 IN33 40 IN 41 48 OUT 1 8 OUT 9 16 Yamaha Digital Console Fig 2 Connection of four X6R units and one DD32R In this example Ports A and B of the DD32R FX are outputs sending their signals to first two cards installed in console s slot Ports C and D are connected to the third card with 8 inputs and 8 outputs each Each of these ports transmits four AES EBU 8 audio channels outputs and receives four AES EBU inputs The configuration of the ports as inputs and or outputs as well as routing monitoring and Emulation Mode setup is carried out with OPTOCORE CONTROL The control data from Yamaha console is transmitted to DD32R FX via BI C cable The BI B cables audio transmission and the BNC cable word clock are connected as shown in Fig 2 DD32R FX 20 26 rev 2 3 OPTOCORE Connection Tables Principal Ports A D AES AES EBU In or Output AES EBU In or Output cnam 1 2 3 4 5 6 7 a Audio 442 344 546
12. R FX 15 26 rev 2 3 OPTOCORE Power Supply The device is optionally equipped with two power inputs and power supply units If one power supply fails due to malfunction of the feeding power line or the power supply unit itself the device will automatically switch over to the other power supply unit In order to make the power supply redundant both power inputs must be connected to the main supply if possible to different phases power supply systems or even better one of them to an uninterrupted power supply UPS The power supply units operate with mains voltage of 100 240 V and frequency of 50 60 Hz Thus the device can be used throughout the world without any modifications or transformers Important The switched mode power supplies operate at very high voltages Coming into contact with the power supplies can lead to considerable electric shock which may result in death To prevent electric shock do not remove any covers of the device Transmission Delay The Optocore system delay including the matrix is fixed to 41 6 us 48 kHz for all channels The additional transport delay per Optocore unit lt 200 ns in the network is insignificant in comparison Overall system delay is dependent on the converters used and the length of network cables in the system Assuming normal cable lengths of lt 700 m per link the additional delay is considered marginal The transmission delay is constant between any points i
13. ctromagnetic compatibility standards laid down in the above named testing regulations Munich 11 12 2013 maa Marc Brunke DD32R FX 7 26 rev 2 3 Page intentionally left blank OPTOCORE DD32R FX AES EBU I O interface for Optocore and SANE Table of Contents Important Safety INStUCtIONS ica abi 3 Purchaser Information acdsiietsiavinl ei RRA ein Re eee as 4 CE FOC Contormity currar ib 7 Device Descriptio riseiras cued cabeshocazdagabs Ri ea al leer ie edi 10 A aa a E E A A E cha iets cevesveecesdusehancscsduinesscetvasuenedss dhe sacnseeaedsaseebereels 12 Rear Panel saccecccatisrgesdectesecethastectechesccattecacctig a aa a EaR paaa eaa a E a a E E EE EE 14 Device Detalle siii shad ontyavea aaeeea a Oda Ea aao E ASAE en a REEE SEEE 15 Optocore Fiber Optic Connection eee eeeeeceeeeeeeeeeeteeeeeeeeeaeeeeaeeeeaeeeeaeeseaeeseaeeseaeeseaeeeeseeeeeeseeeseneeseieeeeeees 15 Principal Ports for AES EBU is cccce5 f b hceheesecesaachpsdecueaceeecebsistegacennsceesscdasaneqesdenessepaede aghdensebpeseteassnaadcesesnete 15 AINE PONS raed can O EE 15 A E 15 Word ClOCK A A A 15 MIS OP OMS irs cra 15 EMMGrmet PONS cc ssicncnosaetasneceneanness E E euveretwediiecageeetteataeeecesieneereree 15 Power SUP PIV incesantes 16 Transmission Delay rosca ea 16 CONTO tecate cabral roo Inici cancela 16 DD32R FX in Network ApplicatiOnS ooooocccnnnocnonnnncccnononnncnnnoncnnnonncnn nro o nr rnnrn rr rra nn rn rr cren rre 16 Third
14. ized distributor dealer Only qualified service personnel may carry out repair and maintenance work on the device The warranty of the device will be voided if any unauthorized maintenance or repair work has been carried out DD32R FX 6 26 rev 2 3 OPTOCORE CE FCC Conformity This document confirms that the DD32R FX bearing the CE Communaut Europ enne label meets all requirements in the EMC directive 2004 108 EG laid down by the Member States Council for adjustment of legal requirements Furthermore the product complies with the rules and regulations of the low voltage directive 2006 95 EG and the Restriction of Hazardous Substances Recast Directive 2011 65 EU RoHS 2 This product bearing the CE label complies with the following standards ratified by CENELEC Comit Europ en de Normalisation Electrotechnique Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use EN 55103 1 Emission EN 55103 2 Immunity EN 60065 Safety requirements FCC notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital de
15. jects of any kind into the device through openings in the casing They may come into contact with dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the device DD32R FX 5 26 rev 2 3 OPTOCORE e Cables and Accessories Only use attachments that are specified by the manufacturer of the device Use high quality properly terminated cables to connect the device The device should only be used with optical fibre cables that are specified for use with the devices optical transceivers and within the specified power budget of the optical transceivers When not in use ensure that the optical connectors on the device and the optical fibre cables are covered with the provided caps Do not place this device on an unstable table tripod cart etc The device may fall which can cause injury and serious damage to the device Any mounting of the device should follow the manufacturer s instructions and should use mounting accessories recommended by the manufacturer of the device e Servicing Do not attempt to service this device yourself The device contains no user serviceable parts components or controls The operation of an opened device is not permitted Such operation can lead to damage of the device s components due to lack of air flow through the device The device may not be serviced altered or modified without authorization from Optocore or an Optocore author
16. k and auxiliary ports of the device are transmitted simultaneously on one fibre while the second fibre of the LINK Interface receives data from the network The second LINK Interface pair is identical to the first one and can optionally be used for network redundancy Principal Ports for AES EBU According to the AES EBU standard each physical channel contains two audio channels with the 32 digital of the four principle ports 64 audio channels are available The ports feature the unique possibility to define them freely as AES EBU inputs or AES EBU outputs in groups of four OPTOCORE CONTROL software should be used to enable disable and configure 32 digital channels as inputs or outputs in groups of four For more details refer to the Optocore Control Software Manual Please note DD32R FX principal AES EBU ports are NOT equipped with Sample Rate Converters Every 3 party device must be locked either to the Word Clock embedded in AES3 frame or to the External Word Clock output of DD32R FX SANE Ports The device is equipped with two RJ45 200MBit SANE Ports capable of transmitting 64 channels of synchronous audio and 100MBit Ethernet SANE 2 port is compatible with MADI over Cat protocol RS485 The auxiliary ports provide four RS485 ports to establish a maximum of four half duplex or two full duplex connections between devices A wide range of bi directional and unidirectional standards can be connected to the ports such as RS485 CAN
17. les and international electric cables which have been supplied on your request and your purchase order cannot be listed above Please note that due to the Ecology reason standard shipment does not contain printed copy of User Manual All latest OPTOCORE user manuals can be downloaded from the website http www optocore com index php support downloads Printed version of User Manual is available on a special demand Please contact support optocore com if printed version is required Company Information Mailing Address OPTOCORE GmbH Lohenstr 8 D 82166 Munich Gr felfing Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www optocore com Email Inqui optocore com DD32R FX 26 26 rev 2 3
18. n the BI B cables the control of the preamps by software or from the console is possible without any further wiring For word clock distribution the Word Clock OUT of the DD32R FX should be connected to the Word Clock IN of one X6R Then using a daisy chain of BNC cables the word clock is passed on to the other X6Rs in the system from the Word Clock OUT to the Word Clock IN of the consecutive X6R etc creating a Word Clock daisy chain Last X6R device in the word clock daisy chain should be terminated in the Optocore Software The BI B cables audio and control data transmission and the BNC cables word clock are connected as shown in Fig 1 DD32R FX 19 26 rev 2 3 OPTOCORE Example 2 The X6R FX unit is connected to a DD32R FX using both Optocore fiber links creating a dual redundant ring topology The word clock is transmitted via fibre and SANE between OPTOCORE DEVICES there is no need for external coaxial cables between the devices In this example a console is fed with Word Clock as shown below however other synchronisation methods are also available The following figure demonstrates the configuration of a 48 send and 16 return system with two Optocore X6R 16MI units one FX and one TP using two input cards each two X6R TP 8MI 8LO units with one input and one output card each and one DD32R FX 16 E ANALOG INPUTS ANALO 16 ANALOG INPUTS ANALO ANALOG INPUTS ANALOG INPUTS G
19. n the network Control All system and device parameters are configured using the OPTOCORE CONTROL software The system can be configured and controlled centrally over the Optocore network with the exception of the initial configuration of the unique identifier ID of the device The OPTOCORE CONTROL software is capable of running multiple instances on the same PC or by using the OPTOCORE CONTROL software s Client Server mode Please note Please refer to the Optocore Quick Start Guide for the basic system configuration and setup For more detailed setup please refer to the Optocore Software Manual DD32R FX in Network Applications The monitoring and operational facilities are only available if a DD32R FX is connected directly to a PC via LAN USB or RS232 In order to connect and control more than one unit tin the Optocore or SANE networks with a PC the Control is transmitted through the network Optocore Control can run multiple times on one PC or use Server Client Mode Third party control Third party protocols for device controlling can be used It is possible to control Optocore preamps directly from Yamaha consoles through DD32R FX with Special Emulation Mode configured The Multiple Emulation Mode feature enables the control of remote preamps in the Optocore network from up to four different consoles DD32R FX 16 26 rev 2 3 OPTOCORE Optocore bandwidth allocation The standard bandwidth allocation of an Optocore
20. o a DD32R FX using Optocore BI B cables as shown in Fig 1 The word clock is transmitted through the word clock I Os using standard 75 Q cables The following figure demonstrates the configuration of a 48 send and 16 return system with four Optocore X6R units using two input cards each two X6R units with one input and one output card each and one DD32R FX 16 ANALOG INPUTS ANALOG INPUTS ANALOG OUTPUTS 41 48 7 16 5 ANALOG INPUTS ANALOG OUTPUTS 33 40 i ANALOG INPUTS 17 32 X6R 16MI AES AES WORD WORD X6R 16MI AES AES WORD WORD PORTB PORTA OUT IN PORTB PORTA OUT IN PORTB PORTA OUT IN I o e O A o X6R 8MI 8LO AES AES WORD WORD PORTB PORTA OUT IN X6R 8MI 8LO AES AES WORD WORD B Cc D WORD PRINCIPAL PORTS CLOCK DD32R FX ok LINK 1 LINK 2 4x SANE1 SANE2 OUT IN OUT IN RS485 Fiber links to the Optocore network Fig 1 Connection of four X6R units and one DD32R In this example Ports A and B of the DD32R FX are configured as inputs receiving AES EBU signals from two X6Rs which are equipped with 16 microphone inputs each Ports C and D are connected to two X6Rs with 8 inputs and 8 outputs each which transmit four AES EBU 8 audio channels outputs and receives four AES EBU inputs The configuration of the ports as inputs and or outputs and the routing is carried out with OPTOCORE CONTROL software The control data is transmitted via the AUX pins i
21. of Optocore distributors dealers Make sure the equipment being returned is packed carefully to protect it from damage during shipment OPTOCORE requires that shipments are pre paid and insured unless specifically authorized in advance We strongly advise not to use simple flight cases without rack in rack mounting Declaration of Liability Optocore accepts no liability for damage caused to other devices through operation of the DD32R FX device Optocore is not liable for any damage caused by shipping accidents misuse abuse operation with incorrect AC voltage operation with faulty peripheral equipment or improper or careless installation of the device Neither OPTOCORE nor anyone involved in the production of the equipment shall be liable for any indirect special disciplinary consequential or incidental damages arising out of the use or inability to use this equipment even if OPTOCORE has been advised of the possibility of such damages In no event shall the liability of OPTOCORE exceed the purchase price of any defective equipment Optocore accepts no claims for compensation whatsoever e g cancellation of events DD32R FX 25 26 rev 2 3 OPTOCORE Shipping Contents The standard shipment of a DD32R FX unit contains the following 1 DD32R FX unit e 1 fibre patch cable LC LC e 2 power cables Any additionally purchased equipment such as optical wave guide cables in required lengths D Sub cables and adapters RS232 cab
22. ose to heat emitting equipment such as power amplifiers Leave sufficient space minimum Y RU between the device and any heat emitting devices housed in the same rack A DD32R FX may be placed on top or beneath other Optocore products except a DD32E without additional space Please Do not populate more than 4 adjacent rack spaces with Optocore devices Maintain 1RU of empty space between each 4 RU of Optocore devices Keep the equipment rack open during operation Ensure air circulation around the devices Maintain at least 200mm 8 clearance behind the rear panel of the devices Water and Moisture etc To prevent fire or shock hazard do not expose the device to direct sunlight dust water or rain during operation or storage DD32R FX 4 26 rev 2 3 OPTOCORE e Cleaning Only use a dry linen cloth to clean the device If the unit is very dirty moisten a cloth using a little water and a small amount of household detergent Never use cleansing agents containing solvents to clean the device e Operating and Storage Temperature Operating temperature 20 C 50C 4 F 122 F ensure proper ventilation Storage temperature 20 C 60 C 4F 140 F Power Supply The device can be disconnected from the power supply by unplugging the power cord The power cords must be freely accessible at all times The device should be disconnected during lightning storms or when the device is unused for a long period
23. port of a total of 32 AES EBU digital audio pairs which equals 64 mono channels These ports are user defined as inputs or outputs in groups of four Device can operate in sample rates up to 192 kHz sample rates above 96 kHz are available upon request Redundant fibre connections can be established using the two provided SFP based LC multimode or singlemode optical LINK interfaces The dual redundant ring structure provides maximum safety in a network with an outstanding low latency It facilitates the use of the advantages of fibre optical transmission in all sorts of temporary and permanent applications especially when long distance connections and high quality audio are required The DD32R FX enables to connect to the SANE network via RJ45 ports It is possible to use SANE as a Cat5 based cost efficient extension to the optical core system SANE ports may be used as point to point MADI over Cat5 or as a bridge interface between SANE and OPTOCORE providing up to 128 input and 128 output channels additionally to the principal AES EBU ports The DD2FR FX provides both word clock input and output It includes also bi directional composite video interfaces Additionally four RS485 ports allow the transport of a wide range of standards such as RS422 DMX MIDI and CAN Bus bi directional requires special firmware version In addition to the audio signals video and data signals are transmitted through the common fibre connection The dual power suppl
24. r data transmission BNC Word clock input allowing synchronization of Optocore devices network from an external word clock source BNC Word clock output for synchronization of external devices BNC Video input for composite video BNC Video output for composite video 4 x D Sub 25 PRINCIPAL PORTS with 8 channel RS422 for AES EBU or data transmission Mains input for power supply 2 100 240 V Mains input for power supply 1 100 240 V SANE Ru 45 interface for data transmission 100 Mbit Ethernet SANE Ru 45 interface for data transmission 100 Mbit Ethernet Full duplex full bandwidth LC type optical interface for Optocore transmission SFP multimode transceiver included singlemode transiver option available on demand Full duplex full bandwidth LC type optical interface for Optocore transmission SFP multimode transceiver included singlemode transiver option available on demand 100 Mbit RJ 45 Ethernet interface 100 Mbit RJ 45 Ethernet interface 14 26 rev 2 3 OPTOCORE Device Details Optocore Fiber Optic Connection The device is equipped with the Optocore FX communication module The OPTOCORE 6 OPTICAL DIGITAL NETWORK SYSTEM utilizes Time Division Multiplex technology TDM with a Fibre Channel based 8B10B NRZI coding Static time slots guarantee a synchronous transmission of all channels at all times without the use of dynamic bandwidth or latency All signals connected to the intercom audio video word cloc
25. rs of the OPTOCORE CONTROL software indicate a normal level Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device should be disconnected during lightning storms or when unused for long periods of time The device must be grounded any disconnection of the grounding is not permitted The internal components of the switched mode power supplies operate at very high voltages Coming into contact with them can lead to considerable electric shock which may result in death Only use attachments specified by the manufacturer This device contains no user serviceable parts only refer to authorised qualified service personnel for any servicing Your warranty will be voided if you tamper with the internal components DD32R FX 3 26 rev 2 3 OPTOCORE Purchaser Information Operating Manual Please read this manual if you call for technical support we will assume that you have already done so Study the operating manual carefully in order to familiarise yourself with the device and its operation It contains vast amounts of information and tips for the proper use of the device It cannot be guaranteed that this operating manual will not contain typographical mistakes or misprints The operating manual is regularly revised and updated
26. s recall and capture of partial or full system configurations The software can be operated offline as well as online with level meters for all channels on the network The LEDs on the front panel of the DD32R FX units allow an instant overview regarding the status of each port DD32R FX 11 26 rev 2 3 OPTOCORE Front Panel Word Clock LED AES status LED Out LED ACT LED AUDIO LINK Master LED OPTO LED SANE LED Device ID Display HEALTH LED PWR 1 LED PWR 2 LED USB plug and LED RS232 plug DD32R FX Indicates the selected word clock source INT Internal word clock The device is a system master BNC External word clock via BNC WC Input NET Word clock received from network Indicates that the entire AES EBU port is ready for data transmission of LED ON AES EBU digital audio LED OFF Data 1 O configuration of AES pairs 1 4 and 5 8 LED ON Outputs LED OFF Inputs Signal status of AES pairs 1 4 and 5 8 LED ON At least one signal is present LED OFF No signal is present Indicates the audio link status SL1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Indicates the Word Clock Master unit Optocore communication is established SANE communica
27. ted pair cable If two or more channels are wired to the same cable a common braided shield should enclose the pairs SANE Ports Use standard fully wired twisted pair cable Cat 5 Cat 5e Cat 6 terminated with RJ 45 connectors SANE utilizes all four pairs of the Cat 5 cable two pairs for standard Ethernet transmission and two pairs for the SANE synchronous audio transport A SANE cable shall not exceed a total cable distance of 100 m RS232 Connection Use a standard shielded RS232 cable Connector Hood Quality Locking screws for D Sub connectors should be compatible with 4 40 UNC Care should be taken in selecting the right type of connector hoods in order to fulfil the requirements of EMl radiation directives Full metal connector hoods should be used approved acc to VDE 0871 FCC 20780 and EMC directive 2004 108 EG providing attenuation gt 40 dB between 30 MHz up to 1 GHz The shield of the cable should have contact to the connector hood USB Connection Use a USB A to USB B cable between the PC and the Optocore device LAN Connection Use standard twisted pair cable Cat 5 Cat 6 with RJ 45 connector Word Clock Connection Use 75 Q coaxial cable with BNC connector Video Connection Use 75 Q coaxial cable with BNC connector Mains Connection Standard power cords with IEC C13 connectors DD32R FX 18 26 rev 2 3 OPTOCORE Hardware Connection Example 1 The X6R units analog to AES EBU converters are connected t
28. tion is established Indicates the unique identification number of the device Green Power supply to the device works temperature is below the limit Power supply 1 is working correctly Power supply 2 is working correctly USB connection for remote control and update via PC Green Indicates data activity D Sub 9 RS232 connection for remote control and update via PC 12 26 rev 2 3 OPTOCORE LAN LINK Indicates the Ethernet link status S1 Ethernet communication is established via SANE 1 rear panel S2 Ethernet communication is established via SANE 2 rear panel UP There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel 10 Sample Rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz DD32R FX 13 26 rev 2 3 OPTOCORE Rear Panel omo RS485 GPIO WORDCLOCK OUT a aa pM gE oO LANI LAN2 LINK LINK2 SANE1 SANE2 o 0 RS485 GPIO plug Word Clock IN Word Clock OUT Video IN Video OUT PORTA POWER POWER SANE 1 SANE 2 LINK 1 LINK 2 LAN 1 LAN 2 DD32R FX Ds 2 1 o VIDEO IN PORT B om _viweo our 4 x RS485 RS422 D Sub 9 auxiliary port fo
29. vice pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at his own expense Changes or modifications not expressly approved by Optocore GmbH could void the user s authority to operate this equipment Industry Canada Compliance Statement This Class A digital device complies with Canadian ICES 003 Avis de conformit a la r glementation d Industrie Canada Cet appareil num rique de la class A est conforme a la norme NMB 003 du Canada The authorised declaration and compatibility certification lies with the manufacturer and can be viewed on request Responsible as manufacturer is OPTOCORE GmbH Lohenstr 8 82166 Munich Gr felfing Germany represented by Marc Brunke Managing Director N B The awarding of the CE label confirms the compliance with legal directives issued for the manufacturer and marketing of electronic and electrical devices As such the CE label is not a seal of quality but rather proof that the device bearing the CE label conforms with the ele
30. vice is warranted against defects in material and workmanship for 60 months 5 years from the date of purchase This warranty does not include mechanical damages caused by misuse This warranty covers the original registered purchaser only and is not transferable This warranty does not apply to devices which have been purchased in used condition or demonstrator equipment OPTOCORE will at its discretion repair or replace a defective product providing that the defect has occurred under normal operating conditions This warranty does not cover damage from acts of God accident abuse neglect contamination unauthorised modification misuse or operation outside of the environmental specifications for the product improper site preparation or maintenance or abnormal conditions of handling This would include over voltage failures and conditions outside of the products specified ratings problems with customer supplied software or interfacing or normal wear and tear of mechanical components OPTOCORE will acknowledge the evaluation of warranty after inspection Not covered by this warranty are defects arising from electromagnetic or electrical interferences deficiency excess or surge of electrical supply air conditioning or humidity This also includes repairs made necessary by dirt abrasion moisture rust corrosion or similar conditions Devices on which the Serial Number has been removed or defaced are not eligible for warranty service
31. y unit with automatic switchover permits a redundant power supply and safeguards against malfunctions in the event of a power supply failure In combination with the other Optocore devices DD32R FX offers a great flexibility to build the network exactly fitting the applications needs For example in combination with a X6R FX on Stage it is the perfect interface to a digital console at FOH A DD32R FX on stage can be used as an interface to all external microphone preamps with AES EBU outputs With Yamaha and Optocore microphone preamps the DD32R FX enables the gain control of the preamps on stage from a Yamaha digital console at FOH The DD32R FX is not only an audio interface but also a video and data interface for a broad range of control data standards If analogue inputs and outputs are needed the DD32R FX serves as the I O unit for the converter units of the X6R V3R or older X6P series Networks with several DD32R FX and other Optocore or SANE devices allow the transport of a huge amount of digital data e g 7686 audio channels with a sample rate of 48 kHz 32 RS485 channels and three video channels 100MBit Ethernet Depending on the fiber optic transceivers distances from 700 m up to 70 km can be covered 100m by Cat5 SANE The DD32R FX and X6R V3R TP can be used together in a SANE CAT5 Network 64 audio channels Ethernet Combinations of SANE and OPTOCORE OPTICAL DIGITAL NETWORK SYSTEM up to 1024 input channels can be made with the