1. Click OK and the Local Area Connection Properties box is displayed again Click OK and close the Network and Dial up Connections panel For Windows Vista Windows 7 From Start click Control Panel View by Category Click Network and Internet Click Change adapter settings Right click on Local Area Connection and select Properties Select Internet Protocol Version 4 TCP IPv4 and click Properties For ease of initial setup you should change the PC IP settings to the following IP address 10 0 0 2 Subnet mask 255 255 255 0 Default gateway 10 0 0 1 Doc 21778_01 ADPRO FastTrace 2 FastTrace 20 by Xtralis Quick Setup Guide 9 3 9 4 NOTE lf the PC being used for configuration is also the Video Central Session Handler PC the IP address should be set to 192 168 1 10 instead gt NL Le 2 Click OK to return to the Local Area Connection panel Again click OK to close this panel Installing the FastTrace 2 Client Software Connect your PC to the FastTrace 2 video system with an RJ45 network cross cable ra i m Ss J Open Internet Explorer and type the address of the FastTrace 2 video system in the address bar If necessary add the setup page to the address htip 10 0 0 10 setup php Default address 10 0 0 10 Subnet mask 255 255 255 0 RJ45 network cross cable FastTrace 2 Click setup exe Click Run to start the installation You can also click
2. 5 4 3 Connecting to a FastTrace 2 Server kk kek kK 5 6 Using ADPRO VideoCentral Platinum 1 s sccssccssssssnsscesssscnnescesssscnnascesssscnnnssecnssecnnsseenessens 5 6 1 Set up FastTrace 2 for Connection with ADPRO VideoCentral Platinum 5 6 2 Set up FastTrace 2 for Alarm Transmission to the ADPRO VideoCentral Platinum 6 6 3 Setting time zone date and time in the FastTrace 2 sccccssseeeeseeesseeeneeeeeenenseneneees 6 64 Save ANG Restart cf wants sara aro ot Ho ad set ET 6 6 5 Set up ADPRO VideoCentral Platinum for Alarm Reception from the FastTrace 2 O 6 Doc 21778_01 ADPRO FastTrace 2 FastTrace 2 by Xtralis Quick Setup Guide 5 1 5 1 1 Packing List After unpacking check for any signs of damage Damage should be reported to your supplier immediately Also check whether all items are present e ADPRO FastTrace 2 server unit e Power cord e CD with client software and manuals e Quick Setup Guide e 19 mounting brackets black e Set of resistors if fitted with MIO EIO input output card e Set of 4 rubber feet to use the FastTrace 2 Server as desktop unit The products will be provided with a plug according to the National Heavy Current Regulations of the country of shipment Installation should be done according to National Regulations Power Requirements The ADPRO FastTrace 2 is designed for 100 240 VAC 50 60 Hz operation It should not sha
3. 1 5240 0077 Australia and New Zealand 61 3 9936 7000 UK and Europe 44 1442 242 330 Middle East 962 6 588 5622 The contents of this document are provided on an as is basis No representation or warranty either express or implied is made as to the completeness accuracy or reliability of the contents of this document The manufacturer reserves the right to change designs or specifications without obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded This document includes registered and unregistered trademarks All trademarks displayed are the trademarks of their respective owners Your use of this document does not constitute or create a license or any other right to use the name and or trademark and or label This document is subject to copyright owned by Xtralis AG Xtralis You agree not to copy communicate to the public adapt distribute transfer sell modify or publish any contents of this document without the express prior written consent of Xtralis Doc 21778_01 ADPRO by 40 xtralis
4. ADPRO Fastlrace 2 FastTrace 21x by Xtralis Quick Setup Guide September 2012 Doc ADPRO by 40 xtralis ADPRO FastTrace 2 FastTrace 20 by Xtralis Quick Setup Guide Disclaimer The contents of this document are provided on an as is basis No representation or warranty either express or implied is made as to the completeness accuracy or reliability of the contents of this document The manufacturer reserves the right to change designs or specifications without obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded Intellectual Property and Copyright This document includes registered and unregistered trademarks All trademarks displayed are the trademarks of their respective owners Your use of this document does not constitute or create a license or any other right to use the name and or trademark and or label This document is subject to copyright owned by Xtralis AG Xtralis You agree not to copy communicate to the public adapt distribute transfer sell modify or publish any contents of this document without the express prior written consent of Xtralis General Warning This product must only be installed configured and used strictly in accordance with the General Terms and Conditions Technical and User Manual and product docume
5. Save to store the files on your PC so that you can run the installation later Click Run to begin the installation of the Client software When showing the License Agreement window you need to agree with the terms Click Agree Accept or modify the installation folder Click Next Accept or modify the work folder Also select your preferred language Click Install The installation is now completed Click Close to exit this installation wizard Launching the FastTrace 2 Client On the desktop double click the FastTrace 2 shortcut 4 Na Pa If no shortcut icon can be found click the Windows Start button choose All Programs and click FastTrace 2 gt FastTrace 2 You will get a login window Doc 21778_01 3 Quick Setup Guide ADPRO FastTrace 2 FastTrace 2X by Xtralis da Add 2 Edit x Delete A Settings Connect 5 4 1 Settings Via Settings you can change the language the skin appearance of the program the work folder in which stills and footage are stored and the Auto restart settings English Francais Deutsch Nederlands Espanol GUI style Windows M Restart required Path C Users Feys FastTrace2 Auto restart o 5 4 2 Adding a FastTrace 2 server to the FastTrace 2 client Launch the FastTrace 2 Client Click Add You will get the window as underneath 4 Doc 21778 01 ADPRO FastTrace 2 FastTrace 20 by Xtralis Quick Setup Guide Lo
6. ad to death or permanent injury Warning This icon is used to indicate that there is a danger of inhaling dangerous substances This may lead to death or permanent injury Tradename statement ADPRO is a registered trademark of Xtralis AG Pty Ltd Contact Us The Americas 1 781 740 2223 Asia 852 2916 8876 Australia and New Zealand 61 3 9936 7000 UK and Europe 44 1442 242 330 Middle East 962 6 588 5622 www xtralis com Doc 21778_01 i Quick Setup Guide ADPRO FastTrace 2 FastTrace 2 by Xtralis ii Doc 21778_01 ADPRO FastTrace 2 FastTrace 2X by Xtralis Quick Setup Guide Contents 1 Packing Lis india 1 2 Power Requirements iu ui a EEE HE 1 3 Safety INSTITUCION SS radica 1 4 Technical DOCUMENTS 2 tect cheeses ests n ken re ados 1 o Installing the FastTrace 2 Client Software on your Computer s lt lt lt s lt rresrr 1 5 1 FastTrace 2 Client Minimum System Requirements eee 1 9 121 HardWare a E EE OE EN 1 9 1 2 SONATO oie unseres 2 5 2 Preparing the network settings on your PC uuususuuunnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnn nennen 2 52 1 Changing the FOS IP Address E O 2 5 3 Installing the FastTrace 2 Client Software ccsscsccesseecseseeenseeceeeesenseceensesenseeneeeees 3 5 4 Launching the FastTrace 2 Client ee aan 3 BA CRUG Suero a cirio 4 5 4 2 Adding a FastTrace 2 server to the FastTrace 2 Client 4
7. ent assessment of the fitness or suitability of the products for your purpose You acknowledge that you have not relied on any oral or written information representation or advice given by or on behalf of Xtralis or its representatives Total Liability To the fullest extent permitted by law that any limitation or exclusion cannot apply the total liability of Xtralis in relation to the products is limited to i in the case of services the cost of having the services supplied again or ii in the case of goods the lowest cost of replacing the goods acquiring equivalent goods or having the goods repaired Indemnification You agree to fully indemnify and hold Xtralis harmless for any claim cost demand or damage including legal costs on a full indemnity basis incurred or which may be incurred arising from your use of the products Miscellaneous If any provision outlined above is found to be invalid or unenforceable by a court of law such invalidity or unenforceability will not affect the remainder which will continue in full force and effect All rights not expressly granted are reserved Document Conventions The following icons conventions are used in this document Caution This icon is used to indicate that there is a danger to equipment The danger could be loss of data physical damage or permanent corruption of configuration details Warning This icon is used to indicate that there is a danger of electric shock This may le
8. er 7 or higher e DirectX 7 The FastTrace 2 Client version 2 01 xxxx is backwards compatible with all V3100 Hybrid versions from version 2 00 xxxx and all V3100 FT versions from version 1 00 0001 However some menus will look different depending on the connected video system O NOTE e It is recommended to install the latest drivers of your graphics card For NVIDIA cards please check the website http www nvidia com For ATI cards please check the website http ati amd com e The client can always be forced into GDI mode Add the line gdi 1 in the General section of the hydra ini file This file can be found in your local work folder Forcing the client to GDI mode is not recommended Preparing the network settings on your PC The FastTrace 2 video system is by default on IP address 10 0 0 10 with subnet mask 255 255 255 0 When installing the client software you need to put your PC in the same IP range e g IP address 10 0 0 2 with subnet mask 255 255 255 0 Changing the PC s IP address For Windows XP From Start gt All Programs gt Accessories gt Communications gt Network Connections right click on Local Area Connection and select Properties From here select Internet Protocol TCP IP and click Properties For ease of initial setup you should change the PC IP settings to the following IP address 10 0 0 2 Subnet mask 255 255 255 0 Default gateway 10 0 0 1
9. gin Name U 2 Cancel IP Address RTSP Port Control Port Connection Type Username Password Please fill in all necessary information Name Enter a description as Name It is recommended to provide a meaningful description to your FastTrace 2 video system IP Address Enter the IP address of the FastTrace 2 by default 10 0 0 10 RTSP Port Set RTSP and Control ports Use the same ports as specified under Control Port System gt Ethernet PPP Connection Type Select the TCP or UDP protocol UDP is recommended but TCP may be required if the connection goes through a router that blocks the UDP packets Username Enter the username and password of an existing user By default you Password can log on with user 0 and password 666777 Click OK to save the added device At this time you can select the newly added video system from the list and connect to it 5 4 3 Connecting to a FastTrace 2 Server Launch the FastTrace 2 Client Select the desired video system from the list and click Connect 6 Using ADPRO VideoCentral Platinum The information underneath is specified for ADPRO VCP but also applies for use of the FastTrace 2 with VSKWin or M3000 software 6 1 Set up FastTrace 2 for Connection with ADPRO VideoCentral Platinum Following information has to be entered before connecting to the ADPRO VideoCentral Platinum e Unit ID e Username and password e IP address and connection
10. nts available from Xtralis All proper health and safety precautions must be taken during the installation commissioning and maintenance of the product The system should not be connected to a power source until all the components have been installed Proper safety precautions must be taken during tests and maintenance of the products when these are still connected to the power source Failure to do so or tampering with the electronics inside the products can result in an electric shock causing injury or death and may cause equipment damage Xtralis is not responsible and cannot be held accountable for any liability that may arise due to improper use of the equipment and or failure to take proper precautions Only persons trained through an Xtralis accredited training course can install test and maintain the system Liability You agree to install configure and use the products strictly in accordance with the User Manual and product documents available from Xtralis Xtralis is not liable to you or any other person for incidental indirect or consequential loss expense or damages of any kind including without limitation loss of business loss of profits or loss of data arising out of your use of the products Without limiting this general disclaimer the following specific warnings and disclaimers also apply Fitness for Purpose You agree that you have been provided with a reasonable opportunity to appraise the products and have made your own independ
11. ports Doc 21778_01 5 Quick Setup Guide ADPRO FastTrace 2 FastTrace 2 by Xtralis 6 2 6 3 6 4 6 5 Open System gt Behaviour gt Alarm transmission Enter the correct value for FastTrace Unit ID value must be a number between 1 and 9999 Click Save Open System gt General gt Users Click Add Select a free user ID value from 0 through 31 with 0 1 and 15 by default reserved Enter the user name Type the password 6 digits and retype it to exclude typing errors Select the Administrator level Click Save Open System gt Connections gt Ethernet PPP For Ethernet parameters enter the final IP address subnet mask and gateway according to the specifications of the network to which the system will be connected For ports modify Control port port 1 and RTSP port port 2 according to the ports configured in the Central Video Platinum software Click Save Set up FastTrace 2 for Alarm Transmission to the ADPRO VideoCentral Platinum To set up the FastTrace 2 Server to send alarms to the ADPRO VideoCentral Platinum open System gt Behaviour gt Alarm transmission Under Activate Alarm Transmission select the option Primary Ethernet Under Primary Alarm Transmission enter the IP address of the VCP computer in the Destination 1 IP address field Click Save Setting time zone date and time in the FastTrace 2 Open System gt General gt Date Time Select the time zone tick Yes for Dayligh
12. re electrical outlets or circuits with devices that may cause significant electrical interference such as air conditioners or a photocopier Some installations may have particularly bad mains power disturbances such as large voltage spikes surges and power sags which may cause system failure In this case power line filters conditioners and or uninterruptible power supplies should be fitted between the ADPRO FastTrace 2 and the mains Safety Instructions The plug is the disconnect device for the FastTrace 2 video systems the socket outlet needs to be installed near the video system and needs to be easily accessible Technical Documents Please download the technical manual and users manual from our website www xtralissecurity com You can also download some technical data sheets on specific items connecting to the FastTrace 2 Installing the FastTrace 2 Client Software on your Computer FastTrace 2 Client Minimum System Requirements Hardware e Pentium 4 1 6 GHz e 512 MB RAM e Graphics card that is compatible with DirectX 7 It is recommended to use a graphics card that allows YUV surfaces and hardware stretching If not compatible the FastTrace 2 client software will force the graphics card to GDI mode which will increase CPU load Doc 21778_01 1 Quick Setup Guide ADPRO FastTrace 2 FastTrace 2x by Xtralis 9 1 2 9 2 9 2 1 9 2 1 1 9 2 1 2 Software e Windows XP SP 2 or higher e Internet Explor
13. t savings and if available enter the NTP server address Select Date and enter time hours minutes seconds Click Save Save and Restart To store all modifications to non volatile memory open System gt Maintenance gt Configuration Management select configuration 1 and click Save To apply the new network settings restart the unit Open System gt Maintenance gt Configuration Management and click System Restart Now you can connect the FastTrace 2 to the final network and use the VCP software Set up ADPRO VideoCentral Platinum for Alarm Reception from the FastTrace 2 Server In the VideoCentral Platinum Client open Tools gt Administration gt Sites and click Add Fill in all parameters as explained in 6 1 Set up FastTrace 2 for connection with ADPRO VideoCentral Platinum Doc 21778_01 ADPRO FastTrace 2 FastTrace 2K by Xtralis Quick Setup Guide Site Details Es Tx Click OK Doc 21778 01 Events SitePulse Notification Owner Location Images Diagram Details Unit 1D 11352 Name FastT race 2 HARI KMMIMM User ID 0 Password Type Save audio video to database Communications C Use backup network connection in case primary fails poa Network Default IP Address 10 Control Port 2000 RTSPPort 1554 HTTP Port 80 ADPRO FastTrace 2 FastTrace 2X by Xtralis Quick Setup Guide www xtralis com The Americas 1 781 740 2223 Asia 862