Home

ClearWater Tech OAS20 111196

image

Contents

1. 120 VAC Ozone Dispersion RING Installation with ClearWater Tech CD10 AD Ozone Generator see instructions next page Atmosphere Use 4 i Without Oiffuser ncn Clearwater Tach Crone Cle ron ts With Gitfuser Ganando Aur Onyer To separate unswitched 120 or 240 Wale Crone iets Check Volye 3 cule adesea a5 Cler Waoter Tach Adje too Peary eee Aur Source imer pticnal racommend c Hete Witi tow meter it moy ke posible tor te DAS to cwar drow e x F e a D D nei builtin air dryer hs Orona ae t Gone Dispersion Ang INSTALLATION WITH THE CLEARWATER TECH CD10 AD CORONA DISCHARGE OZONE GENERATOR l Mount the CD10 AD and the OAS 20 adjacent to each other on a sheltered surface 2 Remove the copper External Loop fitting from the bottom of the CD10 AD Replace this fitting with the two straight copper fittings provided with the OAS 20 3 Connect a length of the supplied 1 4 braided tubing from the OAS 20 air outlet fitting to the ozone left fitting just installed on the CD10 AD 4 Remove the air inlet filter assembly from the OAS 20 and replace with one of the supplied brass 1 4 MPT x barb fittings use Teflon tape on the threads Connect another piece of 1 4 braided tubing from this fitting to the remaining fitting installed on the air dryer side of the CD10 AD 5 Connect the remaining length of 1 4 braided tubing from the barbed fitting on the check
2. of the above components are included Do not throw away any packaging until all components are found in case some have become hidden in the packing materials 6 Model OAS 20 INSTALLATION WITH CLEARWATER TECH MZ 250 S 1200 amp CS 1400 ULTRAVIOLET OZONE GENERATORS 1 HA Securely mount the OAS 20 and the ozone generator adjacent to each other on a sheltered surface within 5 of the tank if possible Remove the round plastic plug covering the access hole for the barbed air inlet fitting on the side of the box portion of the ultraviolet ozone generator Cut a length of the braided tubing provided and attach it between this air inlet fitting and the air outlet fitting on the OAS 20 unit Connect the remaining length of braided tubing from the barbed fitting on the ozone generator to the ozone dispersion ring Place the ozone dispersion ring in the bottom of the tank running the tubing above the water level of the tank Plug the ozone generator power cord into the switched outlet on the bottom of the OAS 20 To initiate operation set the timer by rotating the blue timer dial clockwise matching the current time of day to the TIME arrow Pull outward on the blue tabs to engage the air source at the indicated time for 30 minutes per tab Installation with ClearWater Tech Ultraviolet Ozone Generator see instructions at left Ozone gt ClearWater Tech Air Source Timer Air Outlet ClearWater Tech UV Ozone Generator
3. INSTALLATION AND OWNER S MANUAL Ozone Systems AERATION SYSTEM FOR USE WITH OZONE GENERATOR ON WATER STORAGE TANKS aeration system ClearWater Tech LLC e Reproduction of any kind is prohibited e LIT635 REV111196 INTRODUCTION The OAS 20 aeration system kit is designed for pressurized ozone diffusion with ClearWater Tech ozone generators producing 0 25 to 3 0 grams per hour The OAS 20 consists of an air source with a timer controller RECOMMENDED SIZING For one or more tanks totaling up to 1500 gallons use the ClearWater Tech OAS 20 aeration system For one or more tanks totaling up to 5000 gallons use a ClearWater Tech OAS 60 aeration system NOT YET AVAILABLE Size the ozone generator to match the capacity of the tanks consult your ClearWater Tech representative THE OAS 20 KIT The OAS 20 kit consists of the following components o 1 1 3 2 1 1 1 2 2 6 OAS 20 unit 120 VAC 60 Hz or 240 VAC 50 Hz IEC standard power cord 120 VAC NEMA or selection of 240 VAC 50 Hz configurations are available 1 4 1 D Braided tubing 1 4 MPT x 1 4 Barb Brass Fittings 1 4 MPT x 1 4 Barb Kynar Fitting 1 4 MPT x 1 4 Compression Kynar Fitting 1 4 Barb x 1 4 Coupling Barb Polyethylene Fitting 1 4 Barb x 3 8 Barb Adaptor Coupling Fittings 1 4 x 2 Long Copper Tubing Pieces for use with CD10 AD Hose Clamps stainless steel When opening the package check to make sure all
4. the bill of sale to the end user if the installation date is more 90 days after the original shipment date To validate the warranty a warranty card accompanied by a copy of the bill of sale must be returned to CWT and must include the fol lowing information End user name Complete address including telephone number Date installed Complete model and serial number information Name of company from which the unit was purchased epairs and replacement parts provided under this warranty shall carry only the unexpired portion of this warranty or 90 days whichever is longer Items Excluded from the Warranty This warranty does not extend to any product and or part from which the factory assigned serial number has been removed or which has been damaged or rendered defective as a result of an accident misuse alteration or abuse an act of God such as flood earthquake hurricane lightning or other disaster resulting only from the forces of nature normal wear and tear operation outside the usage parameters stated in the product user s manual use of parts not sold by CWT service or unit modification not authorized by CWT Obtaining Service Under the Warranty Any product and or part not performing satisfactorily may be returned to CWT for evaluation A Return Goods Authorization RGA number must first be obtained by either calling or writing your local authorized dealer distributor or CWT direct prior to shipping the product The problem experienced
5. valve at the bottom of the ozone generator to the ozone dispersion ring Place the ozone dispersion ring in the bottom of the tank running the tubing above the water level of 6 e cord on the CD10 AD into a standard wall receptacle This will provide power to the air dryer built into the CD10 A a the power switch on the CD10 AD to the ON position This will provide power to the ozone generator portion of the CD10 8 a the power cord on the OAS 20 into a standard wall receptacle To initiate operation set the timer by rotating the blue timer dial clockwise to indicate the correct time of day Pull outward on the blue tabs to engage the air source at the indicated time for 30 minutes per tab NOTE Extreme caution should be exercised if this unit is to be used for open atmospheric odor control The use of an ambient air monitor is strongly recommended for safety ClearWater Tech LLC Limited One Year Warranty Summary of the Warranty ClearWater Tech LLC CWT makes every effort to assure that its products meet high quality and durability standards and warrants the products it manufactures against defects in materials and workmanship for a period of one 1 year commencing on the date of original shipment from CWT with the following exceptions 1 The warranty period shall begin on the installation date if the installation is performed within 90 days of the original ship ment from CWT 2 The warranty period shall begin on the date of
6. with the product and or part must be clearly described The RGA number must appear prominently on the exterior of the shipped box es The product and or part must be packaged either in its original packing material or in comparable and suitable packing material if the original is not available You are responsible for paying shipping charges to CWT and for any damages to the product and or part that may occur during shipment It is recommended that you insure the shipment for the amount you originally paid for the product and or part If after the product and or part is returned prepaid and evaluated by CWT it proves to be defective while under warranty CWT will at its election either repair or replace the defective product and or part and will return ship at lowest cost transportation prepaid to you except for shipments going outside the 50 states of the United States of America If upon inspection it is determined that there is no defect or that the damage to the product and or part resulted from causes not within the scope of this limited warranty then you must bear the cost of repair or replacement of damaged product and or part and all return freight charges Any unauthorized attempt by the end user to repair CWT manufactured products without prior permission shall void any and all warranties For service contact your authorized dealer or distributor or CWT direct at 805 549 9724 extension 27 Exclusive Warranty There is no other expressed warrant
7. y on CWT products and or parts Neither this warranty or any other warranty expressed or implied including any implied warranties or merchantability of fitness shall extend beyond the warranty period Some states do not allow limitations on how long an implied warranty lasts so that the above limitation or exclusion may not apply to you Disclaimer of Incidental and Consequential Damages No responsibility is assumed for any incidental or consequential damages this includes any damage to another product or products resulting from such a defect Some states do not allow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may not apply to you Aee eo oO ee amp e oo Oo Legal Remedies of Purchaser This warranty gives you specific legal rights and you may also have other rights which vary from state to state THIS STATEMENT OF WARRANTY SUPERSEDES ALL OTHERS PROVIDED TO YOU AT ANY PRIOR TIME ClearWater Tech LLC 850 Capitolio Way Suite E San Luis Obispo California 93401 Phone 805 549 9724 ext 27 Fax 805 549 0306

Download Pdf Manuals

image

Related Search

Related Contents

Samsung RT43H5321SP Manuel de l'utilisateur  Volet roulant ARZ Solar  パスワーク株式会社 パスワーク株式会社 行  MANUALE DI IGIENE E SICUREZZA DEL LAVORO IN  NEWS - Nuova Mapa Srl  Servotesteur CMS sur CONRAD, Accessoires divers pour servos  Proceedings of the 4th Annual Linux Showcase  Stûv 21 + Frischlufteinlass für die Verbrennung Gebrauchsanweisung  Folletos de Ventas Resipod Family  取扱説明書(PDF)をダウンロード  