Home

User Manual - Weintek HMI

image

Contents

1. Remote control with highly efficient Data Transmission unlike VNC Image File Transmission Select VNC or Easy Access using Easy Access Client to control HMIs When to Use EasyAccess and Improve Convenience for Users When you d like to manage multiple HMIs in group Including Upload Download project When the HMIs you manage are distributed everywhere and all with different IP addresses that are difficult to be memorized and identified How EasyAccess Differs from VNC EasyAccess is more efficient than VNC in the way of transmission e EasyAccess can centralize management of multiple HMls EasyAccess allows users not to memorize IP addresses of HMIs e EasyAccess costs less than VNC in across LAN settings System Requirements PC XP VISTA Windows 7 j Series HMI X Series HMI Ly WE NTEK EasyAccess User s Manual OS image MT8000i 20100818 or later MT8000X 20100906 or later EasyBuilder 8000 4 2 0 or later How to Start Firstly just enable your HMI to connect with Internet That is to give HMI a Public IP address for external access Once the network environment of HMI is settled users can use EasyAccess The way of setting is similar to using VNC to remote control HMI from another LAN Or build a FTP HTTP server for external access The steps of web setting are same If you encounter difficulties in assigning Public IP to HMI Please refer to 2 Public Private IP and NAT Concept If
2. Its role in EasyAccess is to control remote HMI Users should set HMI port mapping in Virtual Server Example Public 202 200 13 60 18000 gt Private 192 168 1 107 8000 VNC Port NO 5900 This Port is unchangeable on HMI but other port numbers can be set in Virtual Server for mapping B9051 Defined as the permission for HMI to log in Easy Access ON Login available OFF Login unavailable B9052 Defined to show if HMI is connected to EasyAccess Server ON Connected OFF Disconnected Le WE NTEK EasyAccess User s Manual Virtual Server Settings in Router The illustration below shows a setting example of Virtual Server it differs in routers from different companies please refer to each router s user manual In the blue frame HMI IP is set as 192 168 10 20 FTP Port as 21 mapped to Public Port 5000 HMI Port as 8000 and mapped to Public Port 8000 Public Private Port 5000 gt 192 168 10 20 21 Port 8000 gt 192 168 10 20 8000 VIRTUAL SERVER PORT FORWARDING The Virtual Server option allows you to define a single public port on your router for redirection to an internal LAN IP Address and Private LAN port if required This feature is useful for hosting online services such as FTP or Web Servers Save Settings Don t Save Settings 24 VIRTUAL SERVERS LIST APPLICATION RULES QOS ENGINE NETWORK FILTER ACCESS CONTROL WEBSITE FILTER INBOUND FILTER Tame PUBIT lt chegue
3. an extension number list Of course if you wish to block away all external connections for one of the ports of your PC there s no need to set Port Mapping Table in NAT correspondingly Most of the router products in the market nowadays have NAT Firewall Router function Please note the Port Mapping Table mentioned in this manual is called Virtual Server in most of routers in the market From now on in this manual we ll call it Virtual Server Conclusion The role of PC in the example shown in this manual can all be viewed as HMI since HMI itself is a computer which you can set IP and Port for it Weintek i X series HMI currently support EasyAccess function Except for the HMI port originally set for communication default 8000 can be user defined FTP port is added fixed to 21 can t be changed The newly added FIP port is allowed for EasyAccess function only Lyh WE NTEK EasyAccess User s Manual 3 Easy Access Settings Port and System Register Needed in HMI FTP Port No 21 Standard FTP function used to transmit XOB file and History file in Easy Access This port number can t be changed that is It will always be 21 in every HMI Users should set FTP port mapping in Virtual Server Example Public 202 200 13 60 20021 gt Private 192 168 1 107 21 HMI Port NO 8000 It s the communication port you may know You can change it from EB8000 menu Edit E gt System Parameter Settings Y gt Model gt Port no
4. cc cccecccecceeeeeeeeeeseeeseeeaes 10 PuINICKManie TO YOUN AM Freres 12 Few Points to be Confirmed AQ ln ccccccccseceseeceeeceeeseeeeeeeeeeeeeeeeees 13 4 Easy Access Client asia ap asasiaee cach sioeeinsnsisiosicenaisiosicsmsiddiageemambadmenaeneseoieeapeeasninades 14 Installing EasyAccess Client ces ccesssssencatcnucacatsencaeabiancntubacuaneutnennneabnccaneatees 14 xecu utMo EasSyACCOSS OXO daces asec acenteeseaeusnnaccuaguasceaasncdanadinenctasesascuasanaea 14 Synchronizing in EaSyACCeSS History ccccccceccceeeeeeeeeeeeeeeeeeeeeeeeeaes 16 Use EasyAccess in Local Network ccccccsccsecceeceeceeeseeseeeeeeseesaeesans 18 Restrictions of Objects When Running Remote Control 00 19 5 Notes IMPOnaNT ssc aseecceacetscascostacosentsenesantaeacnsansearsoussesentoneasusneacasoes 21 Ly WE NTEK EasyAccess User s Manual 1 EasyAccess Introduction Overview The purpose of EasyAccess is for users to control remote HMI instantly and conveniently no matter which corners in the world you are Via Internet users can login HMI to Weintek EasyAccess Server Server then obtains HMI location and related information You can then use EasyAccess Client on PC to observe all your HMls on line and pick one to execute remote control What Can EasyAccess Do Centralized management of multiple HMIs remote or in LAN Operate HMIs remote Ex HMI in a remote factory or in LAN on local PC
5. Calendar VNC executable Path Network Environment Testing i M Synchronize history i Sync Setting d EasyAccess Debug Demo Joey Weintek xob 18 Ly WE NTEK EasyAccess User s Manual Please click Local Network the display is shown above Select tab and input the desired name in HMI Namel field then click Search Search All is for viewing all HMIs in LAN You may select IP tab to specify an IP address to run EasyAccess The way to operate is same as selecting Easy Access Restrictions of Objects When Running Remote Control When running remote control project in remote HMI will run without stopping You can even run different projects to remote control which is an advantage of EasyAccess This section lists the restrictions in objects when remote controlling Object EasyAccess Animation Backup data is from Recipe or History in PC not HMI Data Block Display History Data Display History data is from PC not HMI History data is stored in PC and this won t change Data Sampling the content of history data in HMI Data T ransfer Disable Time based PC will only display the alarm triggered after Alarm Bar executing EasyAccess PC will only display the alarm triggered after Alarm Display executing EasyAccess Real Time PC will only display the alarm triggered after Event Display executing EasyAccess Historical History d
6. with the off line label ahead of the NAME In the Grid the NAME HMI PORT FTP PORT will be displayed NAME is the Nickname you gave your HMI you can identify HMI with it so no need to memorize IP EasyAccess needs XOB file of HMI project to run remote control If you don t have it please select then input directory and file name as shown above This will be used later when saving project If you already have XOB file select Use an existing XOB filel input directory or click to find it EasyAccess will directly use this project file to run remote control e Click Easy Access to activate remote control If you select HMI s XOB file before remote controlling the remote project will be got first There will be a Progress Bar in the window to show the progress of transmission The bottom of the window also reports current status is for testing if the current network environment is able to run EasyAccess This test is checking the number of router hops More than one router hop may disable the execution of EasyAccess There can still be some other reasons EasyAccess cannot be run even to pass this test Network Environment Testing i Pere ere rrr eer rrr rrr rr Launch VNC enables you to execute VNC simulation for HMIs logged in to EAS server Firstly please click VNC executable to specify your VNC executable Visit EasyAccess website to fill in for HMI the available port that you already op
7. you already know how to assign it please read from 3 EasyAccess Settings If your HMI is not connected to Internet through Router NAT Firewall no settings for Router are needed for using EasyAccess Ly WE NTEK EasyAccess User s Manual 2 Public Private IP and NAT Concept Suppose one day you want to invite your colleague in the same office for lunch usually you just pick up the phone and dial his extension number maybe 107 to find him But for inviting your customer for lunch you have to call first the main number of his company then extension in order to find him Similarly except for service hotline companies won t give each of its employees a personal main number in general Every person outside your company looking for you needs to know the main number of your company and your extension number only to call you Let s get back to the subject Usually when we communicate with remote PC 2 types of info are needed IP and Port If you access external network through a router the IP will be separated to Public and Private Take the phone example above for outside Public IP is the main number of the company and Port is the extension What about Private IP It is the extension inside But how can we tell the difference of Port and Private IP Please see illustration below Inside your office LAN a m Kevin Larry Joey IP 192 168 1 107 IP 192 168 1 118 IP 192 168 1 230 Port 21 Port 21 Port 21 Port
8. 8000 Port 8000 Port 8000 There are 3 computers in the same office belong to Kevin Larry and Joey Each of them owns an IP individually but starts with 192 168 x x This is the typical feature of Private IP In other words computers in your office may all have IPs with 192 168 x x It is possibly the same as for the computers in your customer s factory What is more coincident is that maybe among the computers in your office and your customer s factory you both have the computer with IP 192 168 1 107 4 WS WE NTEK EasyAccess User s Manual However when you get communication with 192 168 1 107 you are linked to Kevin s computer instead of your customer s This is as when calling extension number 107 you can talk with your colleague but not someone who also has extension number 107 in your customer s office For more information about Private IP please refer to RFC1918 Address Allocation for Private Internets The illustration above also shows that even the IP of the 3 computers differ from each other they are all individually set with Port 21 and Port 8000 Every Port represents one kind of service Take phone case as example Port 21 is a typical FTP service port which is not a regulation but is commonly known Port 8000 is the default of Weintek HMI set for communication which is also not the regulation You can modify this default from EasyBuilder 8000 menu gt Edit E gt System Parameter Settings Y gt Mo
9. SNS rn 9 _ _ gt pJ Communication lezli Application Name Always FIREWALL SETTINGS ADVANCED WIRELESS IP Address Pri Protocol Inbound Filter fig2 168 10 20 lt lt ComputerName eoa s alowall ADVANCED NETWORK 3 O Pe pp y Sedie w 500 A always yl IP Address Private Protocol Inbound Filter 192 168 1 2 lt Computer name 21 Allow Al se Check and Memorize Your MAC address Go to System information Networkl in HMI tool bar check MAC address It is 00 22 2F B5 90 05 in this example as shown Remember the address since it will be used in further settings Here we remind users to note a common mistake easy to make B is easily mixed up with 8 and vice versa please take a second look system information Network Version Ip Address 192 168 1 201 Net Mask 299 295 255 0 Route Address 192 168 1 254 MAC Address 00 22 2F B5 90 05 We NTEK EasyAccess User s Manual Visit www ihmi net to Login HMI Info All the info of HMI related to EasyAccess must be registered in www ihmi net The required info MAC FTP Port Public HMI Port Public Please plan your Port Mapping properly before registration Firstly visit www ihmi net and input your User ID and Password the same as in Weintek forum the following will be shown after login successfully The illustration below shows there s one HMI successfully registered C
10. System Parameter Settings Y gt System Settingi gt Login EasyAccess Server oy stem Parameter Settings Font l Extended Menors Device startup language after redownloading the project Laneuage 1 Execute tut MACRO when po F Auto logout Bub nine When a user does not operate the HMI for longer than the seting time the system will automatically logout Hide system setting bar Hide mouse cursor Use LB S062 to open hardware setting dialog Disable buzzer Prohibit remote HMI connecting this machine Disable upload function effective after rebooting HMI jor set LBOO23 on Prohibit password remote read operation for t LBO053 on Prohibit password remote write operation for set LBGO54 on VNC server Password from project Password 111111 LWW protection Disable LW remote write via COM port or ethemeti RV protection Disable EW remote write via COM port or ethernet Compile project and download it to HMI l1 Ly WE NTEK EasyAccess User s Manual A Nickname for Your HMI Return to HMI setting bar go to System settings gt HMI name Jto input a name for HMI and click then Reboot HMI From now on when you manage your HMI in EasyAccess this name will be used to identify HMI You don t have to memorize IP address any more The following shows Default HMI in HMI name which is the default value name Default HMI 12 Lib WE NTEK EasyAccess User s Manu
11. TL BT a Eia Sia i Ta Se T _ 7 er che Put touch screens online they are all at your hand p sy Access LB a a impo t so IS NO EasyAccess User manual 3 E AS Ly WE NTEK EasyAccess User s Manual EasyAccess 1 EasyAccess INTFO GUC HON is sicis ensisasiesncisvosicsmarnosianstnaslispcnisasnenaeasnansededoanetasiahss 2 NGEN aea a E meinen E E N 2 What Can as VACCCSS DO sacs asec acscasacacenaieaccengseseseesgnadcwesaesgasseaneauwanasecades 2 When to Use EasyAccess and Improve Convenience for Users 2 How EasyAccess Differs from VNC cccccccceccceceeeeeeeeeeeeteeeseeeaeeeaeeeaess 2 SYSTEM REQUIFEMENNS ccccccecececcceecaeecseecececseceeesaeesueeseeeseeseuesaseseeess 2 FOW TO lA 2 eee E 3 2 Public Private IP and NAT Concept cccccccecceeeeeeeeeeeeeeeeeeeeneeeeeeneeees 4 3 Easy Access Settings a ssaseragn sae songmaenuaatacasauanueseanecuste aasaceeceseaumaeusaamenaanaanene 7 Port and System Register Needed in HMI ccc ceccceeeceeeeeeeaeeeaeeeeees 7 Virtual Server Settings in ROUteEr ccccecccecceeeceeeceeeceeeeeesaeeseeseeeseeeaes 8 Check and Memorize Your MAC address c cccceeeceeeeeeeeeeeaeeeeeeeeeees 8 Visit www ihmi net to Login HMI Inf0 ccc ceccceeeceeeeeeeeeeseesseeeseeeaes 9 Open Your Project in EasyBuilder8000
12. al Few Points to be Confirmed Again OS image version MT8000i 20100818 or later MT8000X 20100906 or later e EasyBuilder 8000 Version 4 2 0 or later Is the HMI MAC address registered in www ihmi net correct Are the HMI Port FTP Port registered in www ihmi net the externally accessible ports of Virtual Server Are the Virtual Server HMI Port FTP Port and VNC Port for external access correctly mapped to HMI Port FTP Port and VNC Port of HMI ls the number set in Edit E gt System Parameter Settings Y gt Model gt Port no J in HMI project the one you planned Does it match to the setting in Virtual Server Did you check Edit E gt System Parameter Settings Y gt System Setting Login EasyAccess Server in HMI Project Does your HMI have a nickname Did you reboot HMI Is the status of LB9051 ON Does the Router you set in Virtual Server need to be rebooted after setting A while after confirming and rebooting LB9052 must be ON which shows HMI login EasyAccess Server in www ihmi net successfully 13 re WE NTEK EasyAccess User s Manual 4 Easy Access Client Installing EasyAccess Client Please go to www ihmi net and download EasyAccess Client ZIP format Uncompress it find Setup exe The installation procedure is simple and therefore we skip the details here Just click then Next The default directory is C EasyAccess Executing EasyAccess exe Execute C EasyAcc
13. ata is from PC not HMI History data is stored in PC and this won t change Event Lo 9 the content of history data in HMI Function Key Disable screen hardcopy 19 Direct Window nction Key Ly WE NTEK EasyAccess User s Manual Indirect Window Meter Display Moving Shas O S Media Player Play the media in PC not in HMI Multi State Numeris Changing Window Allow O O 5 C O r Retrieving Current Base Window Disable General PLC Control Disable Backlight Control write back Disable PLC Control l Backlight Control Disable Audio Control Allow Macro Disable Screen Hardcopy Disable Data Touch Trigger Allow Transfer Trigger based Bit Trigger Disable cheduler Disable Disable auto Disable Disable auto Real Time PC will only display the Sampled Data recorded after executing EasyAccess Historical History data is from PC not HMI Je a lele isle eg 2 2 2 2ia fisis D J N 2 3 o a D D al lt 5 NO Le WE NTEK EasyAccess User s Manual D Notes Important When you revise any HMI info in www ihmi net HMI Port or FTP Port please click again in EasyAccess Client to properly update the info If you change HMI name the HMI must logout EasyAccess Server then login again You may use LB9051 to logout or just reboot HMI If your router has DMZ function disable it If your router has no ALG Application Layer Gateway functi
14. del Port no J For the following let s see the example after adding Firewall NAT Router Your Company Public IP 202 87 116 20 Port 20021 Port 20022 Port 18000 Port 18001 Internet NAT Port Mapping Virtual Server Firewall NAT Router Public IP Private IP Port 20021 gt 192 168 1 107 21 Port 20022 gt 192 168 1 118 21 Port 18000 gt 192 168 1 107 8000 Port 18001 gt 192 168 1 118 8000 Kevin Private IP 192 168 1 107 Port 21 Port 8000 Larry Private IP 192 168 1 118 Port 21 Port 8000 As mentioned companies won t assign phone numbers for each employee too costly Similarly every single computer in the office won t have a Public IP for external access individually in general Take the extension number example the receptionist will transfer calls for us only if we have correct extension numbers As for computer communication the NAT Network Address Translation plays the role of receptionist NAT not only helps us to reduce the need of precious Public IP but also blocks we from the attacks of hackers come from Internet just like a professional receptionist rejecting unnecessary calls from salesmen Lyh WE NTEK EasyAccess User s Manual Illustration above shows a Firewall and added another set of Public IP amp Ports With NAT we can use Port Mapping Table to tell how to transmit packets coming from Public IP to correct Private IP just like the receptionist always has
15. ened for VNC on the router The default VNC port of 15 We NTEK EasyAccess User s Manual EasyAccess website is 5900 If you would like to block the external VNC communication with your HMI please do not open Port mapping on the router In addition the default VNC port for communication in LAN is 5900 which can t be modified and will be used without any setting e is for downloading the xob file to your specified HMI including the HMls not logged in to EAS server must be connected to internet Download Project betting EasyBuilder 8000 path D work Weintek EBS000 Project xob file D work Weintek WinApp Easy Access Projects PC diente Bowrse Password eee onea Synchronizing in EasyAccess History Before you execute EasyAccess you can choose whether to get history data of remote HMI or not After getting the data it will be loaded together when remote controlling In the red circle when click Easy Access if Synchronize history is checked historical data of remote HMI will be synchronized before running remote control 16 Lib WE NTEK EasyAccess User s Manual Easy Access Local Network VNC executable Path Network Environment Testing ID testEA B Password ce k Demo Joey Weintek 202 70 194 104 200271 pee Demo MITSUBSHI Weintek 203 70 194 104 20022 ETVE stop y p aiie mehel Uei 70 194 10 ii Server wwwahminet ofF line Demo Neil Weintek 203 70 194 104 11111 of
16. ess EasyAccess exe default then window below is shown 4 EasyAccess Easy Access Local Network HMI PORT H Demo Joey Weintek 203 70 194 104 20021 Demo MITSUBSHI Weintek 203 70 194 104 20072 off line Demo Neil Weintek 203 70 194 104 11111 off linejJoey7 ABE 192 168 1 22 20021 Taw ihm met J Save Password 05 20100804 or later supports C E a M Synchronize history Use remote HMI s XOB file Syne Setting Use an existing XOB file 1 WeaswAatess hnic Banke toapiWaintek dab jconnecting Easy Access Server connect server successfully searching HMI AMI list is updated di amp conntect sarwer e 2 options are provided on top of this dialogue box and Network The former is for operating HMI logged in to Easy Access Server the later is for operating HMI in LAN Here we select Easy Access 14 W WE NTEK EasyAccess User s Manual Input ID and Password in ID and columns the same as those in www ihmi net then click Search At this moment the Grid on the upper right of the window will display all the information of the HMIs you registered on the website If the HMIs are already logged in to EasyAccess Server they will be displayed in black font on the upper part of Grid If the HMls are not logged in to EasyAccess Server they will be grayed and are displayed on the lower part
17. f line loey7 ABB LoS ABB 2a 2OD21 j Save Password 05 20100804 or later supports O Use remote HMI s XOB file La Use an existing XOB file D EasyAccess Debug Demo Joey Weintek ob connecting Easy Server E ee HMI list is updated disconnect server d E In EasyAccess main dialogue box if Synchronize history is checked setting button will be enabled Click it to do detailed settings After pressing Sync Setting EasyAccess Sync History Setting dialogue box will appear as below Sync all history W Clear old history Start date 20 10 08 19 Calendar End date 2010 08 15 Calendar If Sync All history is checked it means users want to synchronize all historical data All data neglecting dates If Clear old history jis checked before synchronizing old historical data in 17 Ly WE NTEK EasyAccess User s Manual C EasyAccess HMI_memory default will all be erased first If not checked old data will be reserved But the old data will be overwritten by new data in a period of time set by users Use two buttons to set time period Please note that the Start date goes before the End date After selecting press OK to enable synchronizing ssword 804 or later supports F 3 30 i 2 3 4 4 6 Ff is eel EasyAccess Sync History Setting Sync all history J Clear old history End date 2010 08 16
18. lick in window below Hi testEA Edit Profile raga togout Add Language EE EE Search by model type i Series and note Page 1 x MODEL TYPE iSeries HMI MAC ADDRESS 00 0C 26 00 E8 79 HMI PORT 8600 FIP PORT 20022 UPDATED DATE 2010 08 31 22 55 NOTE 7 1200 AA MODEL TYPE i Series z HMI MAC ADDRESS HMI PORT 1765535 FIP PORT t 1765535 NOTE Bes See Input HMI MAC ADDRESS and your HMI Port FTP Port VNC Port in Virtual Server Please note again HMI amp FTP amp VNC Port here refer to Public Port for external access in Virtual Server In MODEL TYPE i Series or X Series can be selected and make notation in NOTE section Click after filling in everything EasyAccess Server will then allow the HMI to login Ly WE NTEK EasyAccess User s Manual Open Your Project in EasyBuilder8000 Go to Edit E gt System Parameter Settings Y gt Model gt Port no Jand input your planned HMI Port No Note HMI Port here is set in your HMI meaning that adding IP makes it as a Private IP example 192 168 1 107 8000 In other words you must match HMI Port No with the Private IP in Virtual Server as shown below oy stem Parameter Settings Ed Font Extended Memory Printer Backup server Device Model Creneral System Setting Security Timer Clock source HMI RTC yt Printer wm SCO Ly WE NTEK EasyAccess User s Manual Then Check Edit E gt
19. on you can only normally run EasyAccess with one HMI The reason is Router without ALG limits your Port 21 for external access to be mapped only to Port 21 of one IP in the network Also Virtual Server allows only one FTP service to run for external access The way of using ALG in a router varies from one to other The extreme case can go Router limits you to set FTP service to Port 21 which will disable EasyAccess to operate normally If it doesn t work for multi HMI to execute Easy Access following this manual please refer to manual of each router or enquire the router supplier The xob file uploaded from EasyAccess can be decompiled If users would like to protect the project from being decompiled for safety please tick Decompilation is prohibited when compiling the project Weintek HMI Corp 48501 Warm Springs Blvd STE 102 Fremont CA 94539 Tel 1 510 897 6670 Web www weintekhmi com Email sales weintekhmi com 21