1. The fog exits the nozzle at a very high temperature Keep a minimum distance of 6 5ft 2 m from the nozzle to the nearest object The product s nozzle is very hot during operation and it remains hot for a long time after operation has stopped The maximum ambient temperature is 104 F 40 C Do not operate this product at a higher temperature In the event of a serious operating problem stop using this product immediately Do not add perfume alcohol gasoline or any other flammables to the fog fluid Operates best with MICROH s MAXIMUM water based High Density Fog Fluid HDF CAUTION Never touch the device during operation The housing may heat up CAUTION The electric connection must only be carried out by a qualified electrician 3 MOUNTING AND INSTALLATION Caution For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture Whether installing inverted on a truss ceiling or set on a flat level surface see illustration below Be sure this fixture is
2. fluid fill line Be sure to not over fill the tank Replace the cap and plug unit in Turn the power switch on you will notice the tank lights up RED Once the unit is ready for use the illuminated tank will change to BLUE Heat up will take 3 minutes DMX Select the address using the 9 pin DIP switch located on the back of the unit DMX CHANNEL MODE Channel Function Value _ DESCRIPTION 000 004 NO FUNCTION 1 VOLUME 005 255 FULL OUTPUT FOR 30 SEC CONTINUOUS 5 SEC BURSTS AFTERWARDS DMX Address Quick Reference Cahrt DIP SWITCH POSITION puxoip 9 of of of of of of of of al 3 3 al al al 3 q SWITCH SET Mel fof of of a a a y of of 0 0 Add 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 2134 66 98 130 162 194 226 258 290 322 354 386 418 450 482 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485 _6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 _8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 941 73 105 137 169 201 233 265 297 329 361 393 425 457 489 116 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 120 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 22 54 86 118 150 182 214 246 278 310 342 3
3. kept at least 0 5m 1 5 ft away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting Points Overhead mounting requires extensive experience including calculating working load limits A knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture are all imperative and should only be performed by a qualified technician Improper installation can result in bodily injury and damage Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Clamp Mounting The MICROH FOG HORN 1200DMX fogger provides a unique mounting bracket assembly that integrates 2 brackets to be used to mount on a truss or the floor When mounting this fixture to truss be sure to secure an appropriately rated clamp to the included bracket fitted through the center hole As an added safety measure be sure to attach at least one properly rated safety cable to the fixture Regardless of the rigging option you choose for your MICROH FOG HORN 1200DMX fogger always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never
4. secure a safety cable to a carrying handle 4 DMX 512 CONTROL CONNECTIONS This fixture complies with international USITT DMX standards and can be used with either a 3 pin or 5pin DMX connector Plug in the provided 3pin XLR cable to the female 3pin XLR output of your controller and the other side to the male 3pin XLR input of the MICROH FOG HORN 1200DMX To connect the units to DMX you must daisy chain the fixtures together as referred in the diagram below Always end your DMX 512 connection with a DMX terminator DMX OUTPUT CONTROLLER FIXTURE 1 FIXTURE 2 FIXTURE 3 VIX IN VIX IN VIX VIX IN VIX REPEAT UPTO 30 UNITSIN MASTER SLAVE MODE S SS SS SS w N AAA XLR CABLE XLR CABLE XLR CABLE DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket COMMON En DMX512 OUT 2 DMX512 IN 3 Data SPIN XLR 3 PIN XLR For installations where the DMX cable has to run a long distance or is in an electrically noisy environment it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 1202 u 2 1 PIN 3 PIN2 5 SETUP Be sure the unit is unplugged from the power source remove the cap from the tank and add the MAXIMUM fog fluid up to
5. 74 406 438 470 5021 125 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 126 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 6 Z O E Dn O a I 8 E 7 c O TIMER MANUAL REMOTE The FOGHORN1200DMX can be operated manually or with the included timer remote control When the GREEN LED lights up the unit is ready for operation Press the GREEN button to manually fog To engage CONTINUOUS FOGGING press the RED toggle switch The RED LED will lights up indicating that the CONTINUOUS FOGGING is ON To disengage press the RED toggle switch once again The RED LED NTERVAL DURATION will extinguish To engage the TIMER press the YELLOW toggle switch OUTPUT The YELLOW LED will lights up indicating that the TIMER is ON Adjust the 3 dials to set your INTERVAL DURATION and OUTPUT To disengage press the YELLOW toggle switch once again The YELLOW LED ell MAE will extinguish WIRELESS REMOTE Plug the wired receiver into the fog machines 5 pin port labeled Remote Control Press the either of the fog buttons and the fog machine will output fog for as long as you hold down the button 9 TECHNICAL SPECIFICATIONS Heat up Time 3 5 Mins Tank Capacity 2 5L Spraying Distance 15m Output 10000 cu ff min Voltage 110V AC 60Hz Power 1400W Weight 13 1Lbs 10 MAINT
6. ENANCE AND CLEANING The following points have to be considered during the inspection 1 All screws for installing the device or parts of the device must be tightly connected and must not be corroded 2 There must not be any deformations on the housing colour lenses fixations or installation spots ceiling Suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage must be handled by a skilled installer or technician Any safety issues must be resolved CAUTION DISCONNECT POWER BEFORE SERVICING i ap Dun A In order to keep the fixture in good condition and extend the life we suggest regular cleaning to the fixture 1 Clean the inside and outside lens each week to avoid the light output from darkening due to accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation instructions Should you need any spare parts please order genu
7. MIEROFH 3 www microhdj com USER MANUAL FOG HORN 1200DMX Keep this manual for future reference 1 INTRODUCTION AND UNPACKING Thank you for purchasing the MICROH FOG HORN 1200 fogger For your own safety and knowledge please read this manual before installing or operating the device This manual covers the important information on installation and applications Please install and operate the fixture according to instructions Meanwhile please keep this manual for future reference The MICROH FOG HORN 1200 fogger is manufactured following CSA standards complying with international standard DMX512 protocol This fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos Please carefully unpack it when you receive the fogger and check if it was damaged during the transportation Please check whether the following items are included inside the box Fixture One Power Cord One User Manual One Wireless Remote One Wired Remote One 2 SAFTEY INSTRUCTIONS CAUTION AN ELECTRIC SHOCK WARNING USE EXTREME CAUTION WHEN HANDLING WIRES Safety Notes Read all the following Safety Notes before working with this product These notes include important information about the installation usage and maintenance of this product This product contains no user serviceable parts Any reference to servicing in this User Manual will only apply to properly trained MICROH certified te
8. chnicians Do not open the housing or attempt any repairs All applicable local codes and regulations apply to proper installation of this product Personal Safety Always disconnect this product from its power source before servicing Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing during operation because it may be very hot Do not drink or become in contact with the fog fluid If you do call your local emergency service 911 in the CDA US for help Mount this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Make sure there are no flammable materials close to this product while it is operating When hanging this product always secure to a fastening device using a safety cable not included Power and Wiring Make sure the power cord is not crimped or damaged Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product s specification label Never connect this product to a dimmer pack or rheostat Never disconnect this product by pulling or tugging on the power cable Operation Do not operate this product if you see damage to the housing fluid tank or cables Have the damaged parts replaced by an authorized technician at once Be sure that no ventilation slots on the product s housing are blocked
9. ine MICROH parts from your local dealer IF YOU SHOULD EXPERIENCE ANY PROBLEMS OR ISSUES PLEASE CONTACT MICROH PROFESSIONAL PRODUCTS BY EMAIL AT info microhdj com In the event that your unit is defective in any way please contact your local dealer to obtain an RA number for service repair Disclaimer MICROH believes that the information contained in this manual is accurate in all respects However MICROH assumes no responsibility for any errors or omissions in this document MICROH reserves the right to revise and make changes to the content of this document without obligation that MICROH notify any person or company of such revision or changes This does not in any way constitute a commitment by MICROH to make such changes MICROH may issue a revision of this manual or a new edition to incorporate such changes Notes 10 MICROH 2 www microhdj com

Download Pdf Manuals

image

Related Search

Related Contents

Avaya 16CC Telephone User Manual  炭酸水製造機が破裂し、手に大けがを負う事故が発生  Newsletter 82 - Mars 2015 - Fédération francophone de Gymnastique  Wireless Broadband Router  Tripp Lite NS2000SR User's Manual  Samsung ЖК дисплей 52" SyncMaster  StarTech.com 3 ft USB Y Cable for External Hard Drive - Dual USB-A to Micro-B  OPERATING INSTRUCTIONS - Sport  GUÍA DE REFERENCIA RÁPIDA  