Home

9540 DVR Manual

image

Contents

1. m Ll pa mn m Per um HDD Management PTZ Control 7 im d mn n E E Juery System Info E Query Log Info L i Clear Log Picture 4 36 Add Group Delete User Delete the current user Choose the user and click delete user button Delete Group Delete the current group Choose the group and click delete group button Page 55 GROUP luser ii Name admin Memo administrator group Picture 4 37 Delete Group 4 5 3 Online User Look up the network user information in the local DVR You can choose the network user and cut the connection Then the user is locked until next boot strap m OLAPALALLLALLLLL ACO AAA AAA d Main Menu gt Advanced gt Online User User Name Login Type Picture 4 38 Online User 4 5 4 TV adjust Refer to chapter 3 5 7 Page 56 4 5 5 Auto Maintain The user can set the auto reboot time and auto file deleting time limit Main Menu gt Advanced gt AutoMaintain Every Thursday at OL 00 Picture 4 39 Auto maintain 4 5 6 Restore The system restore to the default setup You can choose the items according to the menu Main Menu gt Advanced gt Restore Please select setting entries that you want to default Select all General Encode Record Config gt Alarm Sel Network NetService GUI Display RS232 Account The Configuration of Channel Encoding Channel title T
2. Modify Group Modify the existed team attribute Modify Password Modify the user password You can set 1 6 bit password The blank ahead or behind the char string is invalid The middle blank in the char string is valid Note The user who possess the user control purview can modify his her own or other users password Main Menu Advanced Account Modify Pass User Name ladmin E Old New Contirm Picture 4 34 Modify Password Add user Add a user in the team and set the user purview Enter the menu interface and input the user name and password Choose the team and choose whether cover using the user Cover using means that the account can be used by multiple users at the same time Once choose the team the user purview is the subclass of the team Page 54 We recommend that the common user s purview is lower than the advanced user Main Menu gt Advanced gt Account gt Add User User Name o Kcuseable m Password 2 Confirm o GROUP EN Shutdown the device Channel Title Schedule Backup HDD Management PTZ Control Picture 4 35 add user Add Group1 Add a user team and set the purview There are 36 different purviews shut down the equipment real time surveillance playback recording setup video file backup and so on Main Menu gt Advanced gt Account gt Add Group N Name Memo Authority Channel Title un i E rn i LZ gt nu
3. Page 15 3 5 Desktop shortcut menu In preview mode you can right click mouse to get a desktop shortcut menu The menu includes main menu record mode playback PTZ control High Speed PTZ Alarm X Output color Setting Output adjust Logout view1 4 8 9 16 screens EN Main Menu Record Mode PlayBack PTZ Control HighspeedPTZ Alarm Output Color Setting E Output Adjust Logout O view 1 O view 4 EA view 8 Ed View 9 E view 16 Picture 3 2 Shortcut Menu 3 5 1 Main menu When you login the system main menu is shown as below El Main Menu E Systcm O Logout Cancel Picture3 3 Main Menu Page 16 3 5 2 Playback There are two methods for you to play the video files in the hard disk 1 In the desktop shortcut menu 2 Main menu gt Record gt Playback Note The hard disk that saves the video files must be set as read write or read only state 4 5 1 Picture 3 4 video playback 1 listed files 2 file information 3 file searching 4 file backup 5 Operation hint 6 Playback control Listed files Look up the listed files that accord with the searching criteria File information Look up the found file information File backup Backup the chosen file Click the button and operate as followed Note The storage must be installed before the file backup If the backup is terminated the already backup can playback individually Page 17 PlayBack gt Backup E Nam
4. Domain Port of FTP default 21 User Name User name of FTP Password Password of user Max File Length Max length for upload files at every packed default 128M DirName Directory of uploading files Wireless Config ADSL through 3G net card use CMS to visit and config the device Page 46 Main Menu gt System gt NetService gt Wireless Config Enable v Tvpe AUTO Wireless AP AccessPoint Dial Number 777 Uscr Name ctnet mycdma c Password SRG eS III IP Address Cancel Picture 4 25 Wireless Config Enable Choose Enable to make all settings available Type Dial type default AUTO Wireless AP 3G access point Dial Number 3G Dial Number User Name User name of 3G Password Password of dial user IP Address IP address got from dial Mobile Monitor Setup To visit the device by mobile pls make a router mapping of this port and use CMS to monitor and operate it by protocol Main Menu gt System gt N etService gt Mobil Y Enable Port Picture 4 26 Mobile Monitor Setup Enable Select itto make sure abnormal function workable Port Its a port of mobile monitoring which you need to make a router mapping of if want to visit it by mobile Page 47 UPNP UPNP protocol can auto port forwarding on router make sure UPNP is running on router before use it Main Menu gt System gt NetService gt UPNP Enable Make sure UPNP is running on router befor using this Cancel Picture
5. only the listed IP address can connect the DVR The 64 IP addressed are supportive in the list When choosing the black list the listed IP address can not connect the DVR The 64 IP addressed Page 44 are supportive in the list You can delete the set IP address by y in the options Note When the same IP address is in the white and black list at the same time the black list precedence is higher Main Menu gt System gt NetService gt IP FILTER Enable O Banned IP Cancel Picture 4 22 IP IP FILTER DDNS It is the abbreviation of dynamic domain name server Local domain name Provide the domain name registered by DDNS User name Provide the account registered by DDNS Password Provide the password registered by DDNS When the DDNS is successfully configured and start you can connect the domain name in the IE address column to visit Note The DNS setup must be configured correctly in the network setup Main Menu gt System gt NetService gt DDNS DDNS Type CN99 v Enable OK Cancel Picture 4 23 DDNS setup Page 45 FTP setup FTP is available only when alarm happens or alarm activates record and snapshot it will upload related record and snapshot pictures to FTP server Main Menu gt System gt NetServ ice gt FTP Enable User Name Password OK Cancel Picture 4 24 FTP setup Enable Click Enable then all settings will be available Server IP IP address for FTP server Port
6. 22 Value input blank Preset Pattern AutoScan AutoPan Tour Page Switch Cancel Picture 3 12 PTZ Control 2 Cruise between Points Multiple preset points connected cruise lines call cruise between points the PTZ run around on the line 1 Cruise Between Points Settings Cruise lines is connected by multiple preset points setting procedure is as follows otep1 In Picture 3 10 the Direction key will turn PTZ to designated location click Settings button to enter Picture 3 13 Step 2 click Cruise buttons the write proper value into the Cruise Line and Preset Points blank then click Add Preset Points button complete setting also can add and delete cruise line which has been set up Step 3 repeat step1 and step2 until set out all the preset designated cruise lines Remove Preset Please input preset value in the blank click Remove Preset button then remove the preset points Remove Cruise Line Input the number of cruise line click Remove Cruise Lines button then remove the cruise lines set Page 23 Function Presel Cruise Button p reset P Patrol No Cruise Line Blank Border s Del Preset _ Del Tour Picture 3 13 Cruise Between Points Settings 2 The Calls of Cruise between Points In Picture 3 10 click Page Shift button enter PTZ control menu as shown in Picture 3 12 Please input the number of cruise in the value blank then click Cruise between Points button PTZ begins to
7. 4 27 Enable Choose Enable to make sure all UPNP settings available HTTP Route will automatically distribute HTTP port for the device when IE viewing it need this port eg 60 12 9 26 66 TCP Router will automatically distribute TCP port for the device when monitoring via CMS it need this port MobilePort Router will automatically distribute Mobile Port for the device when mobile monitor it need this port 4 4 5 GUI Display Configure the video output parameters including the front output mode and code output mode Front output In the local preview mode include channel title time display channel title record status alarm status bitrate info transparency and region cover Code output In the network surveillance and video file mode include channel title time display channel title record status alarm status bitrate info transparency and region cover Page 48 NB Main Menu gt System gt GUI Display Channel Title Set Time Display Y Channel title W Record Status v Alarm Status 9 Transparency f 255 Resolution 1024 768 hd Channel Region Cover Time Display Y Channel Title Y Set OK Cancel Picture 4 28 GUI Display Channel Title Click the channel name modify button and enter the channel name menu Modify the channel name The 16 Chinese characters and 25 letters are supportive Time Display means the selective state Display the system data and time in the surveillance window Channel Titl
8. bits Include 5 8 options Default 8 Stop bits Include 2 options Default 1 Parity Include odd check even check sign check blank check Default void Page 50 4 4 7 RS232 setup Main Menu gt System gt RS232 Function Console Baudrate 115200 Data Bits g Stop Bits Parity None Picture 4 30 RS232 setup Serial Port Function Common serial port is used to debug and update program or set up specific serial port Baud rate Choose the corresponding baud rate length Data bits Include 5 8 options Stop bits Include 2 options Parity Include odd even mark space 4 4 8 Tour setup Set the patrol display l means that the tour mode is turned on You can choose the single window four windows nine windows sixteen windows patrol display or single display Page 51 e Main Menu gt System gt Tour Enable Tour Interval Return after finished 1 J Picture 4 31 tour setup interval Set the patrol switch interval The set range is 5 120 seconds Note means turn off on the patrol 4 5 Advanced 4 5 1 HDD Manage Configure and manage the hard disk The menu displays current hard disk information hard disk number input port type status and overall capability The operation include setup the write read disk read only disk redundant disk hard disk format resume default Choose the hard disk and click the right function button to execute Note Read Write Disk The equipment
9. can write or read data Read only Disk The equipment can read data but can not write data Redundant Disk Double backup the video files in the write read disk Page 52 Main Menu gt Advanced gt HDD Manage HDD No Type Status Read Write 11 Read Write Normal 2 Read Write Normal 2 Read Write Normal 3 1 Read Write Normal 4 cad Write Normal Redundant 5 1 sad Write Normal d Write Normal Write Normal Py Recover Write Normal Snapshot Read only Format Disk Partition Picture4 32 HDD Manage 4 5 2 Account Manage the user purview Note 1 The character length is 8 bytes at most for the following user and user team name The blank ahead or behind the character string is invalid The middle blank in the character string is valid Legal characters include letter number underline subtraction sign dot 2 here is no limit in the user and user group You can add or delete the user group according to user definition The factory setup include user admin You can set the team as you wish The user can appoint the purview in the group 3 The user management include group user The group and user name can not be the same Each user only belongs to one group Page 53 i Main Menu gt Advanced gt Account User Name Group Status admin admin GUI L O guest USET Normal L Pu default User Default Use Picture 4 33 Account Modify User Modify the existed user attribute
10. of the hard disk are damaged 3 The hard disk is damaged 4 The SATA port of main board is damaged 4 There are no video outputs in single channel multiple channels and all channels Page 62 8 Possible reasons are as followed 1 The program is not matched Please update the program 2 The image brightness is all 0 Please restore the default setup 3 There is no video input signal or the signal is too weak 4 The channel protection or the screen protection is set 5 The hardware of the DVR is damaged Real time image problems such as the image color or the brightness distortion Possible reasons are as followed 1 When using the BNC output the option between the N mode or PAL mode is wrong and the image becomes black and white 2 The DVR is not matched the monitor impedance 3 The video transmission distance is too far or the loss of the video transmission line is too large 4 The color and brightness setting of the DVR is wrong can not find the video files in local playback mode Possible reasons are as followed 1 The data line of the hard disk is damaged 2 The hard disk is damaged 3 Update the different program with the origin program files 4 The video files to look up are covered 5 The recording is not on The local video is not clear Possible reasons are as followed 1 Theimage quality is too bad 2 The reading program is wrong Reboot up the DVR 3 The data line of the hard disk is damaged 4 Th
11. products equipped with a 3 wire grounding type plug having a third grounding pin This plug only fits into a grounding type power outlet If grounding is not done it may cause malfunction or electric shock 7 Ground connection must not touch gas pipe water pipe or telephone line If grounding is not done properly it may cause electric shock 8 Prevent metallic foreign substance from going inside the product It may cause malfunction or electric shock 9 Do not spray insecticide or flammable spray while driving It may cause fire 10 Place the system in a open place where air ventilation is guaranteed or it may cause over heating and seriously damage the system to be fired 11 Prevent water from instilling inside electrical parts Clean with a dry towel or malfunction or electric shock could result Page 2 Contents IErOQUEIOn IMTOOQUCUO Ns tasado 5 I Product OVOEVIGW na 52555 eaachene san senoraasayacsnassaaseeaisanersensenotaassensanssoace aans cues bcosasstoassanceaansaareaanqenesaeosasesmansanaaees 5 1 22 MIST Tuc HORS S 5 2 Open package check and Cable connections sessi eene enne nnne nnns 7 2 Open packte cBeek auo e ld did dia 7 2 2 A os ioa o tren eO nc IUUD ELEM IAE D MEI MU MEE M E 7 2 EO Dalle Locos o e ed o b ea aei adea e eot uio ead etie ea 8 DEANS CAE AIC I ce ioe eae fs en eae enc E E EE E eae nc iD c ene 8 2 5 Audio and video input and output connections llle nennen ener
12. rn nnn nennen nnns 9 231 VIGEOsIMOUT COMMCCHONS RET UU TER 9 2 5 2 Video output connections ard OpDLHOTFIS ooi eae DIDI eee PME ee 9 29 9 AUdIO SICOhal NDUT iscxtcesiacevasacaeciesadicx xcs eta eoi or eos deut oa eei va Senex evn eua Fen poss enar con becca Goat nsa id etu 10 2 tm 26 6 Sonaro UDU ERO RU T TUI 10 2 6 Adarm input and output CODHCCLHOHBS ood aeree aepo A ASAS 10 2 6 1 Alarm Input Dort Speca OMaria on dor tati ci etd or e bd tus 12 26 2 Alatni OUlDUL Dort SPCCHICAUON As aei D ER Ue ea ee a MEN dU uerius I2 2 6 3 Alarm output port relay parameters ooooooccnnococccnooocccononcnnnonnnnncnnononoconnnncconnnncnnnnnnncnnnnonccnnnnss 12 2 Speed COME Connec dos oda dE MEL IMEEM IM LLMMEML a eee 13 odes T TT TT 14 A A Um RR 14 2 2 O O M IRL E p ARAS t ack aS S pA d MEE 14 Sues SUE TW oralio Per Rep oueivnaeceaeees 15 S PLE VOW TR UL T T UT 15 9 9 DO SKIOD SBOTECUD TEC DIU o onde e E em dau 16 9 9 IMIG MEN A RR 16 SAPADA CK uc scu EU ULM Os 17 E M 20 A A A A cauta onc oca dd 20 SE AC CON MIOi dla 21 300 CANAS a 26 9 54 OUIDUEAGIUSLD card 27 OS BG 0 ENERO m S m TE 27 s durer RR 28 2L Man TAS MU ay 1 AC OI 25 noir 28 AD RECO 30 Al OCONEE CON eiii dt tada 30 422 ondpshob lora ge OPINA ii AA A A di 31 a2 3I A t Mut Mt IM LM ALME ME 32 ANNA ME EY Uo PO oO ee a ee en eee eee 92 d ooa Bunte HOT ordo o PER I
13. Digital Video surveillance System User Manual X The picture might differ according to the specification and model X Contents of this user manual are protected under copyrights and computer program laws Version 9504 8 16 1st Edition 01 Jun 2010 Thank You Thank you for purchasing Before operating the system please read this User Manual thoroughly and retain it for future reference Page 1 Cautions Read Before System Operation Follow these details to prevent material damage or personal injury Signs of Caution and Warning Warning This sign indicates that the user could die or be seriously wounded if not used or installed properly Caution This sign indicates that the user could be wounded or could expect property damage if not used or installed properly Warning Do not expose the product to fog rain or too much humid to decrease danger from electric shock or fire General Warning 1 Use the power cord which is supplied or recommended by the supplier or it may cause fire 2 Do not disassemble or reassemble the product It may cause malfunction or fire 3 Enquire to your vendor for repair It may cause electric shock or fire if the repair is not done properly 4 Do not touch the product with wet hands It may cause malfunction or electric shock 5 Product installation must be ensured to a professional for product installation or it may cause malfunction electric shock or fire 6 Ground applies to video
14. EEE RE Rm ni d 33 sl MOVON Delito 33 A OE 36 439 MISCO LOSS Em 37 AS AAA AM ND BET T 37 47359 NE AAA ora ei ee eee ee ee 38 AN nee eee eee T E IEEE IIIA retro 38 ARO SUC TANS abia 38 da T KAO A O 39 442 Encode Us cas 40 AS INeIWOIK Se U Dinci ai tl ai ent ud eat aba 41 a d 4 es gt AE ahis M oi ui MA E i ee 42 Z2 O e csscsnt a ME URDU EM ALME A ME I UM IAM MEE EN 48 445 P TZ SUD A AE AA AAA 50 AL RS Se SOLU Di cos noo DRIED Du aid mi dams titus 51 4 4 9 TOU SOTA D etia iiit tab edocti eti eei abd aided ia tabes cda stetit aa d dob addas edet eat dead sued dans 51 a MR REMIS T TRU NIE 32 A CNMRIBIBH om HH 52 A Ro A nn ie ere ee ee een ee er ne meee ee 53 AD F ONIN NI I Em 56 AWN AC SU O O 56 AS ce ac hdc ee ee eee ee ease 57 A cem SI tS E UTE RO TRUST en ea 57 A ETE 58 ASI Mer T Re 58 4 6 ADOT O SS oret tem AN 58 AO Z BEO MN M MH 59 AG SLO A A O ae eo Oe 60 2 1 eT A a a O 61 Al SUE COW Ss stc 61 S FAG and AIMLESS ao crests ch esc ren oa es tice cies Soa aan access avs es esta A a estas uae n 62 PEPA RO 62 Ps AV SO 67 Appendix 1 REMOleCOMIONEr Opera lisina A 68 APPENA MOUSE ODEFA OR sacos lala ia ita caricia 69 Appendix 3 Hard disk capability calculation ooooooonnonocononcncnonancnononononononnnnnocnonnncnononcnnnnncnnnnnccnnnnncnns 70 Page 4 1 Production Introduction 1 1 Product overvie
15. LOG Page 60 4 6 4 Version Display the basic information such as hardware information software edition issue data and so on a Main Menu gt Info gt Version Record Channel 16 Extra Channel 0 Alarm In 8 Alarm Output 2 System JF2 00 T00 3uild Date 2010 07 31 11 34 49 Status 34 Picture 4 46 Version 4 7 Shut down system Refer to chapter 3 5 8 Page 61 5 FAQ and maintenance 5 1 FAQ If the problems are not listed please contact the local service or call the HQ service We are willing to offer the service 1 The DVR can not boot up normally Possible reasons are as followed 1 The power supply is not correct 2 Switch power supply line is not in good connection 3 Switch power supply is damaged 4 The program updating is wrong 5 he hard disk is damaged or the hard disk lines are broken 6 The front panel is damaged 7 The main board of the DVR is damaged 2 The DVR reboots automatically or stops working after boot up a few minutes Possible reasons are as followed 1 The input voltage is not stable or too low 2 The hard disk is damaged or the hard disk lines are broken 3 The power of the switch power supply is low 4 Frontal video signal is not stable 5 Bad heat radiator or too much dust or bad running circumstance for the DVR 6 The hardware of the DVR is damaged 34 System can not detect hard disk Possible reasons are as followed 1 The hard disk power supply line is not connected 2 The cables
16. Loss Channel v Enable Period Alarm Output Record Channel n Tour Snapshot PTZ Activation Set Delay Show Message Send Email Buzzer FTP upload Advanced OK Cancel Picture 4 10 Video loss Set method refer to chapter 4 3 1 Motion detect Note Advanced button is the same as rightclick 4 3 4 Alarm input When the equipment obtains the external alarm signal the alarm function is turned on Main Menu gt Alarm gt Alarm Input Alarm In v Enable Type Normal Y Period m Set A Interval Alarm Output Delay Record Channel Tour Snapshot PTZ Activation Delay Show Message Send Email Buzzei FTP upload Advanced OK Bm cance Picture 4 11 Alarm input Page 37 Set method refer to chapter 4 3 1 Motion detect Note Advanced button is the same as rightclick 4 3 5 Alarm output Refer to chapter 3 5 4 4 3 6 Abnormal Analysing and inspecting current software and hardware of the device When some abnormal events happen the device will make a relative answer such as show message and buzzer Ti Main Menu gt Alarm gt Abnormality x Event Type No Disk M Enable Show Message LJ Buzzer Picture 4 12 Abnormal Event Type selecting abnormity you want to inspect Enable Select it to make sure abnormal function workable Show message Automatically alarm cue dialog box come out of the main screen Buzzer Device will have two long nosie di di while alar
17. Menu gt System gt General gt DST Enable Day of Week Date 0l ol O 01 DI n Picture 4 15 DST date 4 4 2 Encode setup Set the video audio code parameter video file remote monitoring and so on Set every independent channel s coding parameter in the left part and set the combine encode parameter in the right part Note Combine encode introduces video compression technique which combines and compresses multi channel s video to a special channel Applying for multi channel playback simultaneously Dial up multi channel real time monitor mobile monitor and so on Fd Main Menu gt System gt Encode EN X Channel la T Compression H264 Resolution CIF 352x288 Frame Rate FPS 25 Bit Rate Tvpe VBR Quality Good Bit Rate Kb S I Frame Interval 2 Video Audio e m Picture 4 16 Encode setup Page 40 Channel Choose the channel number Compression Standard H 264 main profile Resolution Resolution type D1 HD1 CIF QCIF Frame Rate P 1 frame s 25 frame s N 1 frame s 30 frame s Bit Rate Type You can choose limited code stream or variable code stream When you choose the variable code stream there are six image quality options Bit Rate Set the code stream value to modify the image quality The larger code stream value the better image quality D1 1000 1500kbps CIF 384 1500kbps QCIF 64 512kbps Video Audio When the icons are all in reverse displayed the video file is vi
18. There is at least one read write hard disk refer to chapter 4 5 1 Main Menu gt Record gt Record Config Channel l Redundancy Length 60 min PreRecord 5 Record Mode BY schedule Manual Stop Week Thu Detect Alarm Period 00 24 F v 00 00 00 Advanced OK Cancel Picture 4 1 Record Config Channel Choose the corresponding channel number to set the channel Choose the all option to set the entire channels Redundancy Choose the redundancy function option to implement the file double backup function Double backup is writing the video files in two hard disks When you do the double backup make sure that there are two hard disks installed One is read write disk and the other is redundant disk refer to 4 5 1 Length Set the time length of each video file 60minutes is default value PreRecord Record 1 30 seconds before the action time length is decided by the code stream Record mode Set video state schedule manual or stop Schedule Record according to the set video type common detection and alarm and time section Manual Click the button and the according channel is recording no matter the channel in any state Stop Click the stop button and the according channel stops recording no matter the Page 30 channel in any state Period Set the time section of common recording The recording will start only in the set range Record type Set recording type regular detection or alarm Regular P
19. Tour eattern Picture 3 15 Boundary Scan Setup 2 Boundary Scan Calls In Picture 3 10 click Page Shift button then enter PTZ control menu as shown in Picture 3 12 Please input the number of scan in the value blank then click Scan button PTZ begins to work on the scan line Click Stop button to stop 5 Horizontal Rotating Click Horizontally Rotating button PTZ begins to rotate horizontally relative to the original position of the camera Click the Stop button to stop 6 Rotate Click on horizontal Rotating button PTZ turn around 7 Reset Page 25 PTZ restart all the data clears to 0 8 Page Shift In Picture 3 12 click Page Shift button into Picture3 16 setting auxiliary function Auxiliary number corresponding to auxiliary switch on the decoder PTZ Control Direct Aux Oper Light i Close Aux Num Oper Open Close Page Switch Cancel Picture 3 16 Auxiliary Function Control Intuitive Auxiliary Operation choose auxiliary equipment select Open or Close button switch control Auxiliary Number The operation of corresponding auxiliary switch according to PTZ agreement Page Shift In Picture 3 16 click Page Shift button enter the Picture 3 17 PTZ Main Menu the menu itself can be control by the menu control buttons 3 5 6 Color setting Set the selective image parameters current channel for single window display and cursor place for multi win
20. able hard disk and so on through net download the files in the hard disk Page 5 Playback individual real time video recording as well as searching playback network surveillance recording check downloading and so on multi playback mode zoom at arbitrary region Net operating through net tele surveillance in the real time tele PTZ control tele recording check and real time playback Alarm linkage multi route relay alarm output which is convenient for the alarm linkage and light control at the spot protecting circuits at the alarm input and output interface which protects the main machine from damage Communication interface RS485 interface which fulfills the alarm input and PTZ control standard Ethernet network interface which fulfills the telecommuting function Intelligent operating mouse action function fast copy and paste operating for the same setting Page 6 2 Open package check and cable connections 2 1 Open package check When you receive the DVR please check first First please check whether there is any visible damage to the package appearance The protective materials used for the package of the DVR can protect most accidental clashes during transportation Then please open the box and get rid off the plastic protective materials Check whether there is any visible damage to the DVR appearance At last please open the machine crust and check the data wire in the front panel power wire the connection betwee
21. adeoff between the image quality precedence and fluency precedence Fluency precedence and self adaption are valid only when the assistant code stream is turned on Otherwise image quality precedence is valid 4 4 4 NetService Choose the network service option and click the set button to configure the advanced network functions or double click the service button to configure the parameters i e Main Menu gt System gt NetService Net Server Met Server Info PPPOE O NTP 0 NTP 1O EMAIL 0 Your SMTP Server 25 IP FILTER X 0 0 DDNS DDNS Set Invalid FTP i FTP ARSP Decorder Wireless Config l Mobile Monitor 0 34599 UPNP 0 Picture 4 18 NetService Page 42 PPPoE setup Main Menu gt System gt NetServi ce gt PPPOF Enable Picture4 19 PPPOE Input the user name and password that ISP Internet service provider provides After saving it reboot up your system Then the DVR will build a network connection based on PPPoE The IP address will change into dynamic IP address after above operation is well done Operation After PPPoE dialing successfully look up the IP address in the IP address and obtain the current IP address Then use this IP address to visit the DVR through user port NTP setup Main Menu gt System gt NetService gt NTP Enable min Picture 4 20 NTP The NTP server must be installed in the PC Host computer IP Input the IP address insta
22. all the damaged hard disks then install a new one behind serial number means the current working disk such as 1 If the corresponding disk is damaged the information will show 4 6 2 BPS Display the code stream Kb S and hard disk capability MB H in real time It displays as the wave sketch map Page 59 Channel Kb S Channel Kb s 1054 z 9 1043 1054 IE 10 1043 1054 l 1043 1043 12 1043 1043 13 1043 1043 14 1043 1043 15 1093 1043 lo 1093 Picture 4 44 BPS 4 6 3 LOG Look up system log according to the set mode Log information include system operation configuration operation data management alarm affair recording operation user management file management and so on Set the time section to look up and click the look up button The log information will display as a list one page is 128 items Press Page up or Page down button to look up and press delete button to clear all the log information A Main Menu gt Info gt LOG Type Start Time 2010 08 12 00 00 00 End Time 2010 08 13 00 00 00 Log Time 2010 08 12 10 31 49 Log In User default Los 2010 08 12 103150 RecoverTime 2010 07 31 11 44 78 2010 08 12 103230 Log Out User default Log 2010 08 12 10 32 30 Log In User admin Logl 2010 08 12 10 32 38 Save Configuratio Location 2010 08 12 10 32 38 Save Configuratio Regular 2010 08 12 10 3239 shut Down 2010 8 12 10 32 39 Picture4 45
23. ation 8 directions control is supportive 4 directions in Front panel is supportive High speed PTZ Full screen show channel image Left press mouse and control PTZ to rotate orientation Left press mouse and then rotate the mouse to adjust the zoom multiple of the camera Set Enter the function operation menu Page switch Switch between different pages Page 21 Special functions 1 Preset Set a location for the preset calls the preset points PTZ automatically turns to the setting position 1 Preset option Set a location for the preset procedure is as follows Step1 in Picture 3 10 click the Direction button will turn into preset position click the Settings button to enter Picture 3 11 Step 2 click the Preset button then write the preset points in the input blank Step 3 click Settings button return the Picture 3 10 Complete setup that is the preset points and preset position corresponds Clear Preset Input preset points click Remove button remove the preset PTZ Config x Preset point input blank Function Preset 5 Preset Tour pois Pattern Set Preset button Patrol No sd m P Border Del Preset Picture 3 11 Preset Settings 2 Preset Point Calls In Picture 3 10 click Page Shift button enter PTZ control interface as shown in Picture 3 12 In the input blank write the preset points then click Preset button PTZ turn to the corresponding preset point Page
24. better stability 2 Overall capability option The hard disk capability formula is Overall capability M channel number time hour capability in an hour M hour The recording time formula is Recording time hour overall capability M Capability in an hour M hour channel number The DVR introduces the H 264 compression technology lts dynamic range is very large so the hard disk capability calculation is based on the estimation values of each channel creating files in an hour Example For one piece 500G HDD real time CIF for recording it will keep recording for about 25 days HDD spaces per channel is 200M H if 4channels real time CIF at 24hours recording uninterrupted it can last 500G 200M H 24H 4ch 26 days Page 70
25. ckup Type All gt Channel m Start Time 8 2010 08 11 00 00 00 EN Remove End Time 12010 OS 11 16 SO 20 Add O Channel File Name Length Required Remaining 0 00 KB 1 00 GB Start Cancel Picture 4 4 File Backup Remove Clear the file information Add Show the file information satisfying the set file attributes Start pause Click the play button to start the backup and click the pause button to stop the backup Cancel During backup you can exit the page layout to carry out other functions 4 3 Alarm Function Alarm functions include motion detect video blind video loss alarm input and alarm output 4 3 1 Motion Detect When system detects the motion signal that reaches the set sensitivity the motion detect alarm is on and the linkage function is turned on Page 33 Main Menu gt Alarm gt Motion Detect Channel Enable Sensitivity Middle Region Interval Alarm Output Delay record Channel delay Send Emall FTP nir Tu n a aM Advanced IK Cancel Picture 4 4 Motion Detect Channel Choose the set motion detect channel Enable m means that the motion detect function is on Sensitivity Choose in the six options according to the sensitivity Region Click setup and enter the set area The area is divided into PAL22X18 Green block means the current cursor area Yellow block means the dynamic detect defensive area Black block means the unfence
26. d area You can set the area as followed Drag the mouse and draw the area Picture 4 5 Region Period Trigger the motion detect signal in the set time section You can set according to week or set uniformly Each day is divided into four time sections m means the set valid Page 34 Main Menu gt Alarm gt Motion Detect gt Set Thursday hd 00 00 24 00 00 00 24 00 OK Cancel Picture 4 6 set the time section Interval Only one alarm signal is turned on even there are several motion detect signals in the set interval Alarm output Start the external equipment of corresponding linkage alarm when the motion detect alarm is turned on Delay Delay a few moments and stop when the alarm state is turned off The range is 10 300 seconds Record channel Choose the recording channel multiple option supportive Trigger the video signal when the alarm is turned on Note Set in the recording setup and perform the linkage recording Start detecting video files in the corresponding time section Tour m means that the selective channel is single window alternate patrol preview The interval is set in the MainMenu gt System gt Tour Snapshot Choose record channels when alarm happens system triggers related channels for snapshot signal Note For Snapshot activationppls go to set period detect and alarm enable at MainMenu gt Record gt Record config PTZ Activation Set the PTZ activation when the alarm is t
27. deo and audio multiplex stream Combine Enable Combine Enable When the icons are all in reverse displayed opening combination coding functions Mode multi channel playback is used in all channels playback simultaneously and the narrowband transmission is used in multi channel real time remote monitoring simultaneously at narrowband state especially used in mobile monitor 4 4 3 Network setup W Main Men u gt System gt NetWork Net Card Wire Netcard DHCP Enable IP Address 92 168 1 Subnet Mask 255 255 Gatew ay Primary DNS Secondary DNS TCP Port HTTP Porl HS Download Transfer Policy Quali ty Prefer T Picture4 17 Network Page 41 Net Card You can choose cable network card or wireless network card DHCP Enable Obtain IP address automatically not suggested Note DHCP server is preinstalled IP address Set the IP address Default 192 168 1 10 Subnet mask Set the subnet mask code Default 255 255 255 0 Gateway Set the default gateway Default 192 168 1 1 DNS setup Domain Name Server It translates the domain name into IP address The IP address is offered by network provider The address must be set and reboot then it works TCP port Default 34567 HTTP port Default 80 HS Download Transfer Policy There are three strategies self adaption image quality precedence and fluency precedence The code stream will adjust according to the setup Self adaption is the tr
28. dow display You can use the desktop shortcut menu and enter the interface The image parameters include tonality brightness contrast saturation You can set different parameters at different time sections Color Setting Period 00 00 00 00 Brightness Contrast Saturation Hue Advanced OK Cancel Picture 3 18 Color Setting Page 26 3 5 7 Output Adjust Adjust TV output area parameters You can use the desktop shortcut menu or enter main menu gt management tools gt Output adjust S Output Adjust Top Deflate Bottom Def late Left Def late Right Deflate OK Cancel Picture 3 19 Output Adjust 3 5 8 Logout Logout shut down the system or reboot up You can use the desktop shortcut menu or enter main menu Logou Picture 3 20 Logout Shutdown Reboot the system logout Quit the menu Offer password next entrance shut down Quit the system Turn off the power supply When press the shut down button there is schedule hint After three seconds the system is shut down Cancel midway is of no effect reboot Quit the system Reboot up the system 3 5 9 Window switch Preview in single window four windows eight windows nine windows sixteen windows according to your choice Page 27 4 Main menu 4 1 Main menu navigation Set the recording configuration recording type recording time section Record playback Set recording look up recording play video file storage D
29. e means the selective state Display the system channel number in the surveillance window Record Status means the selective state Display the system recording status in the surveillance window Alarm Status means the selective state Display the system alarm status in the surveillance window Bitrate info means the selective state The ninth window displays the code stream information in the nine window preview status Transparency Choose the background image transparency The range is 128 255 Resolution set display resolution Channel Choose the set code output channel number Region Cover means the selective state Click the cover area button and enter the corresponding channel window You can cover the arbitrary using mouse Black region is for output Time display and Channel Title Page 49 4 4 6 PTZ setup c Main Menu gt System gt PTZ Config PTZ Device RS485 Device Channel Protocol PELCOD NOME Address Baudrate 600 9600 Data Bits g E Stop Bits f ITIR Parity None None Cancel Picture 4 29 PTZ setup Channel Choose the dome camera input channel Protocol Choose the corresponding dome protocol PELCOD as an example Address Set as the corresponding dome address Default 1 Note The address must be consistent with the dome address Baudrate JChoose the corresponding dome baud rate length You can control the PTZ and vidicion Default 115200 Data
30. e Type Remain Total Detect Dev USB DISK 1 00 GB 1 00 GB Dev IDE DVD RW 1 00 GB 1 00 GB Backup Erase Stop Cancel Picture 3 5 detect the storage Detect Detect the storage connected with the DVR such as hard disk or universal disk Erasure Choose the file to delete and click erasure to delete the file Stop Stop the backup Backup Click backup button and the dialog box is popped up You can choose the backup file according to the type channel and time backup Main Menu gt Record gt Backup gt Backup Type All Channel f Start Time 12010 08 00 00 00 Remove End Time B 12010 08 1 b ng npe Add O Channel File Name Length amp Required Remaining 0 00 KB 1 00 GB Start Cancel Picture 3 6 recording backup Remove Clear the file information Add Show the file information satisfying the set file attributes Start Pause Click the play button to start the backup and click the pause button to stop the Cancel During backup you can exit the page layout to carry out other functions Page 18 File searching Search the file according to the searching parameter Search Condition File Type All v Read Write z Channel nBaBBaanaBiuan Start Time 2010 08 01 00 00 00 End Time 2032 01 01 00 00 OO Play Search Cancel Picture 3 7 file searching File type Set the searching file type Channel Set the searching channel Start Time Set th
31. e hard disk is damaged 5 he hardware of the DVR is damaged There is no audio signal in the surveillance window Possible reasons are as followed Page 63 1 Itis not an active tone arm 2 Itis notan active sound box 3 The audio lines are damaged 4 The hardware of the DVR is damaged 9 There is audio signal in the surveillance window but mo audio signal in the playback state Possible reasons are as followed 1 Setting issues the audio option is not chosen 2 The according channel is not connected with the video 10 The time is wrong Possible reasons are as followed 1 Setting is wrong 2 The battery is in bad connection or the voltage is too low 3 The oscillation is damaged 11 The DVR can not control the PTZ Possible reasons are as followed 1 There is something wrong with the frontal PTZ 2 he setting connection or the installation of the PTZ decoder is not correct 3 The connections are not correct 4 The PTZ setting of the DVR is not correct 5 The protocols of the PTZ decoder and the DVR are not matched 6 Ihe address of the PTZ decoder and the DVR are not matched When multiple decoders are connected the far port of the PTZ decoder line A B must connect a 12092 resistance to reduce the reflection otherwise the PTZ control is not stable 8 The distance is too far 12 The motion detect is not working Possible reasons are as followed 1 The time range set is not correct 2 The motion d
32. e searching time scan Playback control Refer to the following sheet for more information G Play pause a Backward NS G e Full screen Table 3 2 Playback control key Note Frame by frame playback is only performed in the pause playback state Operation hint Display the function of the cursor place Special functions AN Accurate playback Input time h m s in the time column and then click play button The system can operate accurate playback according to the searching time Local zoom When the system is in single window full screen playback mode you can drag your mouse in the screen to select a section and then left click mouse to realize local zoom You can right click mouse to exit Page 19 3 5 3 Record Mode Please check current channel status o means it is not in recording status e means it is in recording status You can use desktop shortcut menu or click main menu gt recording function gt recording set to enter the recording control interface Record Mode Record Mode All 2 AR O TA ES LO Schedule Se E I NI NE NI NN NM NM NE NM E E NE Manual Stop Picture 3 8 Record Mode Schedule Record according to the configuration Manual Click the all button and the according channel is recording no matter the channel in any state Stop Click the stop button and the according channel stops recording no matter the channel in any state 3 5 4 Alarm output Please check cu
33. e vidicon is in backlighting installation 2 The hard disk capability is not enough 3 The hard disk is damaged 22 The downloading files can not play Possible reasons are as followed 1 There is no media player 2 There is no DX8 1 software or higher edition 3 There is no DivX503Bundle exe file to play AVI video files 4 The DivX503Bundle exe and ffdshow 2004 1012 exe files must be installed in the windows Xp system 23 can not remember the advanced code or network code in the local menu operation Please contact the local service or call the HQ service We will offer the service according the machine type and the program edition 5 2 Maintenance 1 Please brush printed circuit boards connectors fans machine box and so on regularly 2 Please keep the grounding well done to prevent the video or audio signal interfered and the DVR from static or inductive electricity 3 Do not pull out the video signal line or RS 232 port or RS 485 port with the power on 4 Do not use the TV in the local video output port VOUT of DVR It will damage the video output circuit easily 5 Do not turn off the switch directly Please use the turn off function in the menu or press the turn off button in the panel 3 seconds or longer to protect the hard disk 6 Please keep the DVR away from heat resource 7 Please keep the DVR ventilated for better heat radiator Please check the system and maintain regularly Page 67 Appendix 1 Remote controller
34. ed with the state standard which has the high signal to noise ratio low aberration and low interference The image must be clear and has natural color in the appropriate brightness Insure the vidicon signal stable and credible The vidicon should be installed in the appropriate location where is away from backlighting and low illumination or adopts the better backlighting and low illumination compensation The ground and power supply of the vidicon and the DVR should be shared and stable Insure the transmission line stable and credible The video transmission line should adopt high quality coaxial pair which is chosen by the transmission distance If the transmission distance is too far it should adopt shielded twisted pair video compensation equipment and transmit by fiber to insure the signal quality The video signal line should be away from the electro magnetic Interference and other equipments signal lines The high voltage current should be avoided especially Insure the connection stable and credible The signal and shield lines should be firm and connected credible which avoid false and joint welding and oxidation 2 5 2 Video output connections and options The video output is divided into PAL NTSC BNC 1 0Vpp 750 and VGA output selective configuration When replace the monitor by the computer display there are some issues to notice 1 Do not stay in the turn on state for a long time Page 9 2 Keep the computer display no
35. egularly If the time is not correct you must replace the battery we recommend replacing the battery every year and using the same battery type Note The setting information must be saved before replacing the battery otherwise information Page 14 will lose 3 3 System Login When the DVR boots up the user must login and the system provides the corresponding functions with the user purview There are three user settings The names are admin guest and default and these names have no password Admin is the super user purview guest and default s permissions are preview and video playback User admin and guest s password can be revised while their permissions can t be revised user default is the default login user whose permission can be revised but not its password SYSTEM LOGIN User Name ad m l n Password Please Login Cancel Picture 3 1 System Login Password protection If the password is continuous wrong three times the alarm will start If the password is continuous wrong five times the account will be locked Through reboot or after half an hour the account will be unlocked automatically For your system security please modify your password after first login 3 4 Preview You can right click mouse to choose the switch between the windows The system date time and channel name are shown in each viewing window The surveillance video and the alarm status are shown in each window Table 3 1 Preview icon
36. erform the regular recording in the set time section The video file type is R Detect Trigger the motion detect camera mask or video loss signal When above alarm is set as opening recording the detection recording state is on The video file type is M Alarm Trigger the external alarm signal in the set time section When above alarm is set as opening recording the detection recording state is on The video file type is A Note Refer to chapter 4 3 to set corresponding alarm function 4 2 2 Snapshot Storage Optional Setup snapshot parameters for different channels At first time it s set for 24hours snapshot continuously pls go to Main Menu gt Record gt Snapshot Storage for appropriate settings Note lf normal snapshot storage pls setup Snap at Main Menu gt Advanced gt Snapshot pls refer to chapter 4 5 1 HDD Manage Main Menu gt Record gt SnapShot Storage Channel m PreSnap ES Pictures tecord Schedule Manual Thu hal DO od 2 100 od 3 00 OO Advanced OK Cancel Picture 4 2 Channel Select the related channel to set click all to set all channels Presnap Setup presnap picture quantity before recording default is 5 pieces Page 31 Record Set record status Schedule Manual and Stop Schedule Realise snapshot according to record type regular detect and alarm and period Manual No matter what the present channel is in a state once choose manual but
37. etect area set is not correct Page 64 3 The sensitivity is too low 4 Limited by some hardware edition 13 I can not login via web or CMS Possible reasons are as followed 1 The system is windows 98 or win me We recommend updating to windows 2000sp4 or higher Version or installing the software for low edition 2 ActiveX is hold back 3 The version is not exceeded dx8 1 Update the display card driver 4 Network connection failure 5 Network setting issues 6 Invalid password or user name 7 The OMS is not matched the DVR program version 14 The image is not clear or there is no image in network preview state or video file playback state Possible reasons are as followed 1 Network is not stable 2 The user machine is resource limited 3 Choose the play in team mode in the network setup of DVR 4 Theregion shelter or channel protection is set 5 The user has no surveillance purview 6 The real time image of the hard disk recording machine itself is not clear 15 Network connection is not stable Possible reasons are as followed 1 Network is not stable 2 IP address is conflicted 3 MAC address is conflicted 4 The net card of the DVR is bad 16 There is something wrong with the USB backup or writing a CD Possible reasons are as followed 1 The rewritable machine and the hard disk are shared the same data lines Page 65 17 18 19 20 21 5 The data is too much Please stop recording and backup The da
38. etect or format backup equipment back the selective files Motion Set motion detect alarm channel sensitivity area linkage parameters detection defending time section alarm output screen hint recording PTZ patrol Video Set camera mask alarm channel sensitivity linkage parameters blind defending time section alarm output screen hint recording PTZ patrol Alarm Video Set video loss alarm channel linkage parameters defending time loss section alarm output screen hint recording PTZ patrol Alarm Set alarm input channel equipment type linkage parameters defending input time section alarm output screen hint recording PTZ patrol Alarm output oet alarm mode configuration manual shut down General oet system time data format language hard disk full time operation oystem configuratio configuration machine number video format output mode summertime stay time n Set main assistant coding parameter code mode resolving ability Encode frame rate code stream control image quality type code stream value configuration frame between value video audio enable Network Set basic network parameters DHCP and DNS parameters network configuration high speed download PPPOE NTP Email IP purview DDNS parameter Set channel name preview hint icon state transparency cover area GUI display time title channel time fold Page 28 PTZ Set channel PTZ protocol address baud rate date bi
39. grounding voltage signal C When the alarm is connected with two DVRs or connected with DVR and other equipments it should be isolated by relay 2 Alarm output Page 10 Alarm output can not be connected with high power load no more than 1A When forming the output loop it must prevent the big current from relay damage Use the contact isolator when there is a high power load 3 PTZ decoder connections A The grounding of the PTZ decoder and DVR must be shared otherwise the common mode voltage will lead to the PTZ control failure The shielded twisted pair is recommended B Avoid the entrance of high voltage Make the layout reasonably Take precaution from the thunder C In the outlying end connect 1200 resistance paralleled to reduce the inflection and insure the signal quality D The 485 AB lines of DVR can not connected with other 485 output equipments paralleled E The voltage between the AB lines of the decoder must be less than 5V 4 Front equipment grounding note Bad grounding can lead to the burnout of the chip 5 Alarm input type unlimited The DVR alarm output port is constant opening type D 2 3 4 ram m 1 alarm input 2 grounding 3 RS232 4 alarm output 5 RS485 ee mg Alarm output interface constant open type Page 11 RS232 port 485communication interface which is connected with the recording control equipments such as the decoder 2 6 1 Alarm input port specificat
40. he button in gray display indicates nonsupport 3 1 Turn on Plug the power supply and turn on the power supply switch Power supply indicator light shining indicates turning on the video recorder After the startup you will hear a beep The default setting of video output is multiple window output mode If the startup time is within the video setting time the timing video recording function will start up automatically Then the video indicator light of corresponding channel is shining and the DVR is working normally Note 1 Make sure that the input voltage corresponds with the switch of the DVR power supply 2 Power supply demands 220V 10 50Hz Suggest using the UPS to protect the power supply under allowable conditions 3 2 Turn off There are two methods to turn off the DVR Entering main menu and choosing turn off in the turn off the system option is called soft switch Pressing the power supply switch is called hard switch Illumination 1 Auto resume after power failure If the DVR is shut down abnormally it can automatically backup video and resume previous working status after power failure 2 Replace the hard disk Before replacing the hard disk the power supply switch in the real panel must be turned off 3 Replace the battery Before replacing the battery the setting information must be saved and the power supply switch in the real panel must be turned off The DVR uses button battery The system time must be checked r
41. ime title Regional Coverage Video Color 76K 77 Cancel Picture 4 40 Restore Page 57 4 5 7 Upgrade 5 Main Menu Advanced Upgrade Upgrade Position USB DISK Upgrade file bootfont bin Upgrade Cancel Picture 4 41 Upgrade Upgrade choose USB interface Upgrade file choose the file which needs upgraded 4 5 8 Device Info Provide device interface info like audio in alarm in out to be conveniently used for user A Main Menu gt Advanced gt Device Info Audio In Channels Alarm In Channels Alarm Out Channels gt SD Card Record GUI Theme General Picture 4 42 Device Info 4 6 Info 4 6 1 HDD info Display the hard disk state hard disk type overall capability residual capability the recording time and so on Page 58 Main Menu gt Info gt HDD Info Capac it y Lett Capacity Status 639 96 GB 549 80 GB Read Write GB 0 00 MB Normal Read Write 21 69 GB 0 00 MB Normal Read Write 79 99 GB 69 83 GB Normal Read Write 79 99 GB 79 99 GB Normal Read Write 79 99 GB 79 99 GB Normal Read Write 79 99 GB 79 99 GB Normal Read Write 79 99 GB 79 99 GB Normal Read Write 79 99 GB 79 99 GB Normal Read Write 79 99 GB 79 99 GB Normal View recording times Cancel Picture 4 43 HDD Info Clue o means that the hard disk is normal X means that the hard disk is broken down means that there is no hard disk If the user need to change the damaged hard disk you must shut down the DVR and take up
42. ion 1 channels alarm input Alarm input type unlimited The grounding and the com port of the alarm sensor are parallel The alarm sensor is external power supply The grounding of the alarm and the DVR should be shared The NC port of the alarm sensor must be connected with the DVR alarm input port The grounding of the power supply and the alarm sensor must be shared when used in external power supply 2 6 2 Alarm output port specification 1 channels alarm output There is external power supply when using the external alarm equipment Please refer to the relay relevant parameters to avoid the overload that damages main machine 2 6 3 Alarm output port relay parameters Type JRC 27F Interface material rating Rating switch capacity 30VDC 2A 125VAC resistance load maximal switch power 125VA 160W maximal switch voltage 250VAC 220VDC maximal switch current isolation Homo polarity 1000VAC 1minute Inhomo polarity 1000VAC 1 minute Interface and winding 1000VAC 1 minute Surge voltage Homo polarity 1500VAC 10x160us Turn off time Page 12 longevity 50x106 MIN GHz 200x103 MIN 0 5Hz 40 4707 2 7 Speed dome connections 1 Connect the 485 lines of the speed dome with the DVR 485 interface 5 678 7 C NO atIIF pt T2 3 NE NU t T A F jg 2485 ALARM Di 2 Connect the video line with the DVR video input 3 Electrify the speed dome Page 13 3 Basic operation Note T
43. lled NTP server Port Default 123 You can set the port according to NTP server Time zone London GMT 0 Berlin GMT 1 Cairo GMT 2 Moscow GMT 3 New Delhi GMT 5 Bangkok GMT 7 Hongkong Beijing GMT 8 Tokyo GMT 9 Sydney GMT 10 Hawaii GMT 10 Alaska GMT 9 Pacific time GMT 8 American mountain time GMT 7 American mid time GMT 6 American eastern time GMT 5 Atlantic time GMT 4 Brazil GMT 3 Atlantic mid time GMT 2 Page 43 Update Period The same with the NTP server check interval Default 10minutes EMAIL setup If the alarm is turned on or the alarm linkage photos are taken send an email about the alarm information and the photos to appointed address Main Menu gt System gt NetService gt EMAIL Enable L SMTP Server Your SMTP Server ort 25 Need SSL User Name Password Sender Recelver Title Alarm Message Cancel Picture 4 21 EMAIL SMTP server Email server address It could be an IP address or domain name Domain name can be translated only it is the correct DNS configuration Port Email server port number SSL Decide whether using Secure Socket Layer protocol to login User Name Apply the email server user name Password Input the password corresponding to the user Sender Set the email sender address Receiver Send the email to appointed receivers when the alarm is turned on You can set three receivers at most Title You can set as you wish IP Filter setup When choosing the white list
44. m is happening 4 4 System setup Set the system parameters such as General Encode NetWork NetService GUI display PTZ config RS232 and Tour setup Page 38 4 4 1 General s X Main Menu gt System gt General System Time 2010 Date Formal YYYY MM DD TN Date Separator v Time Format 24 HOUR hi Language ENGLISH ile HDD Full Overwrite N DVR No 0 Video Standard Auto Logoul i min OK Cancel Picture 4 13 General setup System time Set the system data and time Date format Choose the data format YMD MDY DMY Date Separator Choose list separator of the data format Time Format Choose time format 24 hour or 12 hour Language English French Portugueses Russian ltalian S Chinese T Chinese Spanish Thai Greek Japanese German Polish HDD full Choose stop record Stop recording when the hard disk is full Choose overwrite Cover the earliest recording files and continue recording when the hard disk is full DVR No Only when the address button in the remote controller and the corresponding DVR number is matched the remote operation is valid Video Standard PAL or NTSC Auto Logout Set the latency time in 0 60 0 means no latency time DST Choose the summer time option and pop the dialog box as followed Page 39 Main Menu gt System gt General gt DST Enable o Day of Week Date bd Ist M Mon M m Ol End mon 7 Cancel Picture 4 14 DST week Main
45. n the fan power and the main board Front panel and rear panel The key function specification in the front panel and the interface specification in the real panel are in the specification Please check the product type in the front panel whether is accordant with the product type you order The label in the real panel is very important for the after service Please protect it carefully When you contact us for after service please provide the product type and serial number in the label 2 2 Hard disk installation For the first use please install the hard disk D disassemble the screw 2disassemble the cover fix the screw of hard disk Page 7 connect the power wire cover the machine 8 fix the cover 2 3 Front panel H 264 Network DVR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 SEARCH 7 2 PTZ 8 3EECORDER 4 SHIFT 5 ESC 6 MENU 7 Direction Button 8 POWER 9 Play previous file 1 10 Play next file 2 11 Slow Play 3 12 Fast Play 4 13 Back or Pause 5 14 Play or Pause 6 2 4 Rear panel 1 2 3 4 5 6 7 8 Page 8 1 Video input 2 BNC Output 3 Audio output 4 Audio input 5 VGA Output 6 RS485 7 USB2 0 network 8 12V power 2 5 Audio and video input and output connections 2 5 1 Video input connections The video input port is BNC connector plug The demand of input signal is PAL NTSC BNC 1 0Vp p 750 The video signal must be accord
46. operation 6 D 5 MM 8 Q2 Serial number Multi window Same function as Multi window button in the front button panel NN Numeric button Code input number input channel switch 3 a Same function as Esc button in the front panel etonbuton Sane ton as son buton inte ton pene rc comemos REN 6 Record mode Same function as Record mode Oe T NEM Page 68 Appendix 2 Mouse operation Take right hand as an example The mouse in USB connection is supported fe 5 8 55 5 Double click one item in the file list to playback the video Double click the playback video to zoom in or out the Double left click screen Double click the channel to make it full screen display double click again to resume the multi window display Left click Choose the according function in the menu Pop desktop shortcut menu in preview state Right click Current shortcut menu in the menu Add or subtract number in the number setting Press middle Switch the items in the combo box button Page up or down in the list Choose the widget or move the tem in the widget Set the motion detect area Drag mouse Set the cover area Page 69 Appendix 3 Hard disk capability calculation Make sure the hard disk installed to the DVR for the first time Pay attention to the IDE hard disk lines connection 1 Hard disk capability There is no limit for recording machine We recommend 120G 250G size to keep
47. rmal working by demagnetizing regularly 3 Stay away from the electro magnetic Interference TV is not a credible replacement as a video output It demands reducing the use time and control the power supply and the interference introduced by the nearby equipments strictly The creepage of low quality TV can lead to the damage of other equipments 2 5 3 Audio signal input Audio port is BNC connection The input impedance is high so the tone arm must be active The audio signal line should be firm and away from the electro magnetic Interference and connected credible which avoid false and joint welding and oxidation The high voltage current should be avoided especially 2 5 4 Audio signal output Commonly the output parameter of DVR audio signal is greater than 200mv 1KQ BNC which can connect the low impedance earphone and active sound box or other audio output equipments through power amplifier If the sound box and the tone arm can not be isolated howling phenomena is often existed There are some methods to deal with the above phenomena 1 Adopt better directional tone arm 2 Adjust the sound box volume to be under the threshold that produces the howling phenomena 3 Use fitment materials that absorb the sound to reduce reflection of the sound 4 Adjust the layout of the sound box and the tone arm 2 6 Alarm input and output connections 1 Alarm input A Alarm input is grounding alarm input B Alarm input demand is the
48. rrent channel status o means it is not in alarming status e means it is in alarming status You can use desktop shortcut menu or click main menu alarm function gt alarm output to enter the alarm output interface Alarm Output Alarm Type Confizuration Manual Sto p Status Picture 3 9 alarm output Configuration Alarm is on according to the configuration Manual Click the all button and the according channel is alarming no matter the channel in any Page 20 state Stop Click the stop button and the according channel stops alarming no matter the channel in any state 3 5 5 PTZ control Operation interface is as followed The functions include PTZ direction control step zoom focus iris setup operation patrol between spots trail patrol boundary scan assistant switch light switch level rotation and so on Note1 Decoder A B line connects with DVR A B line The connection is right 2 Click main menu gt system configuration gt PTZ setup to set the PTZ parameters 3 he PTZ functions are decided by the PTZ protocols PTZ Control Ptz Trace Page Switch Cancel Picture 3 10 PTZ setup Speed Set the PTZ rotation range Default range 1 8 Zoom Clic button to adjust the zoom multiple of the camera Focus Clic button to adjust the focus of the camera Iris Click button to adjust the iris of the camera Direction control Control the PTZ rot
49. t stop bit check configuration Serial port Configuration Set serial port function baud rate date bit stop bit check RS232 Set patrol mode and interval time Hard disk oet appointed hard disk as read write disc read only disc or redundant management disc clear data resume date and so on User Modify user team or password Add user or team Delete user or team management Break the connection with the already login user Lock the account after Manageme Online user break until booting up again nt TV adjust Adjust TV upside downside nearside starboard distance Automatic Set automatic reboot system and automatic deleting files maintenance Resume setup state common setup code setup recording setup alarm Restore setup network setup network service preview playback serial port setup user management Hard disk Display hard disk capability and recording time information Code stream Display code stream information System statistics information Log Clear all log information according to the log video and time information Edition Display edition information information Shut down NEN Logout shut down or reboot Page 29 4 2 Record 4 2 1 Record Config Set the recording parameters in the surveillance channel The system is set 24 hours consecutive recording in the first startup You can enter main menu gt recording function gt recording setup to set Note
50. ta exceeds the backup storage The backup equipment is not compatible The backup equipment is damaged The keyboard can not control the DVR Possible reasons are as followed 1 2 4 The serial port of the DVR is not set correctly The address is not correct When multiple transformers are connected the power supply is not large enough Please give each transformer individual power supply The distance is too far Alarm can not be recessional Possible reasons are as followed 1 2 3 4 The setting of the alarm is not correct The alarm output is turned on manually The input machine is damaged or the connections are not correct There are some problems for specific program edition Please update the program Alarm is not working Possible reasons are as followed 1 2 3 4 The setting of the alarm is not correct The connection of the alarm is not correct The alarm input signal is not correct A alarm is connected with two loops synchronously The remote controller is not working Possible reasons are as followed 1 2 3 4 The remote control address is not correct The remote control distance is too far or the angle is too large The battery is used up The remote controller or the front panel of the recording machine is damaged The storage time is not enough Page 66 Possible reasons are as followed 1 Front vidicon quality is bad The lens is too dirty Th
51. ton it will have snapshot at related channels Stop No matter what the present channel is in a state once choose stop button it will stop snapshot at related channels Period Set normal record period it only startup Snapshot Storage at set period Type Three types regular detect and alarm Record type Three types regular detect and alarm Regular snapshot at set period Detect snapshot at set period when motion detect video blind and video loss which are preset for snapshot enable Alarm snapshot at set period when alarm in which is preset for snapshot enable Note for related alarm function pls refer to chapter 4 3 4 2 3 Playback Refer to chapter 3 5 2 4 2 4 Backup You can backup the video files to external storage through setup Note The storage must be installed before the file backup If the backup is terminated the already backup can playback individually A Main Menu gt Record gt Backup E Name Type Remain Total Detect Dev USB DISK 1 00 GB 1 00 GB 2 Dev IDE DVD RW 1 00 GB 1 00 GB Backup Erase f Stop Cancel Page 32 Picture 4 3 Backup Detect Detect the storage connected with the DVR such as hard disk or universal disk Erase Choose the file to delete and click erasure to delete the file Stop Stop the backup Backup Click backup button and the dialog box is popped up You can choose the backup file according to the type channel and time Main Menu gt Record gt Backup gt Ba
52. urned on Note PTZ activation is set in the shortcut menu gt PTZ control Set the patrol between spots trail patrol and so on Page 35 Main Menu gt Alarm gt Motion Detect gt PTZ Activation None CAM 2 None None CA None None CAM 6 None None CAM 8 None None CA None None CA None None CA None None CAM 16 None OK Cancel Picture 4 8 PTZ Activation Delay When alarm is over recording will last some seconds 10 300sec then stop Show message Pop the alarm information dialog box in the local host computer screen Send EMAIL m means sending an email to user when the alarm is turned on Note Set in the NetService and send email 4 3 2 Video Blind When the video image is influenced by the environment such as bad brightness or reaching the set sensitivy parameter the camera mask function is turned on and the linkage function is turned on e Main Menu gt Alarm gt Video Blind l Channel Y Enable Sensitivity Middle Period Set Alarm Output Record Channel Tout Snapshot PTZ Activation PRE Delay Show Message Send Email FTP upload Advanced OK l cancel Picture 4 9 Video Blind Set method refer to chapter 4 3 1 Motion detect Note Advanced button is the same as rightclick Page 36 4 3 3 Video Loss When the equipment can not obtain the channel video signal the video loss alarm is turned on and the linkage function is turned on ES Main Menu gt Alarm gt Video
53. w The 9504 series DVR is designed specially for security and defense field which is an outstanding digital surveillance product lt introduces embedded LINUX operating system which is more stable It introduces standard H 264mp video compressed format and G 711A audio compressed format which insures the high quality image low error coding ratio and single frame playing It introduces TCP IP network technology which achieves the strong network communication ability and telecommunication ability The series DVR can be used individually or online applied as a part of a safety surveillance network With the professional network video surveillance software it achieves the strong network communication ability and telecommunication ability The series DVR can be applied in the bank telecom electric power system judicial system transportation intelligent housing factory storehouse water conservancy and so on 1 2 Main functions Real time surveillance analog interface and VGA interface VGA interface is equipped selectively surveillance function through monitor or display Storage non working hard disk dormancy processing which is convenient to radiate heat reduce power and extend the life span special storage format which insures the data safety Compression real time compression by individual hard disk which insures the audio and video signal stable synchronization Backup through SATA interface and USB interface such as USB equipment remov
54. work on the cruise line Click Stop button to stop cruise 3 Scan PTZ also can work on the preset scan line repeatedly 1 Scan setup Step1 In Picture 3 10 click Setup button enter Picture 3 14 Step2 Click Scan button the input proper value in the scan value blank Step3 Click Start button enter Picture3 10 here you can set the following items Zoom Focus Aperture Direction and so on Click Setup button to go back Picture 3 14 Step4 Click End button to complete setup Click the right button of the mouse to exit PTZ Config Scan value blank Function Pattern Scan Button gt Preset Patrol No me OL Pattern Border Picture 3 14 Scan Setup 2 Scan Calls Page 24 In Picture 3 10 click Page Shift button then enter PTZ control menu as shown in Picture 3 12 Please input the number of scan in the value blank then click Scan button PTZ begins to work on the scan line Click Stop button to stop 4 Boundary Scan 1 Boundary Scan setup Step1 In Picture 3 10 click Direction button to turn the PTZ to preset direction then click Setup button enter Picture 3 15 select the left boundary return to Picture 3 10 Step2 Please click direction arrows to adjust PTZ direction click Setup button enter Picture3 15 then select the right boundary return to Picture 3 10 otep3 Complete setup that is the position of left and right boundary Line scan button Function Pattern Preset border Patrol No