USER MANUAL - lc2power.com
Contents
1. O LOAD Brake appears and the wind generator brakes 2 Quit manual braking Brake at the top right corner of the display interface Page 8 of 11 _ confirm key on the panel pressed first and then press ESC key It means the wind generator quits braking when brake disappears here Lo a RAE j See x Charge DC OUT 1 If WS ETE tf AN InN e ON O LOAD After wind generator brakes it will stop rotating or rotate at a very slow speed The wind generator is unable to generate electricity Brake disappears and the wind generator quits braking state V Protection Mechanism Protection contents Protection description Remarks General over speed brake or If the rotate speed of wind generator exceeds the preset rotate speed of The controller has brake off braking it will automatically brakes through three phase short circuit and automatic braking the brake is off automatically after 3min function 2 Over speed brake or brake off If there are more than successive 3 overspeed brakes within 30min it will under continuous strong wind be determined as continuous strong wind and the brake can be off automatically only after 4h Exceeding safe temperature When it exceeds the safe temperature because of overhigh ambient The controller has a temperature or overhigh temperature caused by heavy current the system built in temperature will enable over temperate protection automaticall
2. by users for continuous 1min It is day if the photocell voltage exceeds the light controlled off voltage can be set by users for continuous 1min 4 4 Output mode Output mode Specification Normally open output mode The voltage of battery is normal and within the rated load The controller outputs will full power normally Light controlled on time controlled off After dark see 4 3 Day and night identification it outputs according to the output mode set load upper limit and the output off time is subject to the set time Light controlled on off output mode After dark see 4 3 Day and night identification it outputs according to the set load upper limit and the output is off after the dawn 4 5 Instructions for control panel 4 5 1 Start up interface 4 zE LH ERAH a 9 Ch Stone DC OUT as Fe MB xt aR oh A In the start up interface 0 00V shows the current voltage of storage battery Press key to enter into wind generator parameter state and the current rotate speed voltage current and power of wind can be viewed 4 5 2 Wind generator operating parameter state 4 5 2 1 View the current rotate speed of wind generator pa HM xe Charge DC OUT JALAL xt oa Se 0 00M in the picture shows the current actual rotate speed of wind generator Press A to enter into next parameter state and the current voltage of wind generator can be viewed 4 5 2 2 View the current voltage of wind gene
3. it to reduce the current parameter value modified Setting confirmation if under browsing status press it to enter the setting status if under setting status press it to store the parameters and return to the browsing status Cancellation manual switch if under setting status press it to return to the browsing status but not to store the values modified if under browsing status use it as a manual setting key in case of load short circuit or over load 4 2 Description of display content A wind generator oT r BRAKES Tiy Pr _ ARH TSS i Ag i KINO B day and nighte 3 CHARGE i p L output interfaces the conditions on off outpute ane gv oo C status of the battery W E hand brake em wee y ee J output modev Loe a F a PA YE OOO ATON OFF He I set state H e C E a ana SRI 38 s gt lt pa sd ovndbocece F Currently browsing items Digital display area Page 3 of 11 Symbol Description poe Indicating wind generator A symbol of sun indicating daytime A symbol of moon indicating nighttime When battery is fully charged 5 bars inside will all g when the storage battery is over discharged the symbol will flicker and then stop flickering upon recovery from over discharging status when battery storage is under over voltage status a battery status indicator bar will appear and the over
4. voltage symbol B will flicker and then stop flickering upon recovery from over voltage status A symbol of storage battery with the bars inside indicating the battery charge status normal load no output indicator lamp P wili appear while indicator lamp w wil appear when with output under over load status load symbol HE flicker at this time you need to eliminate the excessive load and then press Esc kev to recover the output under short circuit protection av Load status and fault status short circuit symbol will be on at this time you should check the load line and then press Esc key after confirmation for normality to manually recover it to original status See Figure An icon of manual brake when it 4 2 is on it indicates under manual brake status otherwise status of manual brake unlocked See Figure An icon of the item browsed 4 2 currently See Figure Unit icons A current unit A 4 2 V voltage unit V W power unit W H hour M minute See Figure Digital display zone 4 A symbol of light amp time control is a symbol of light amp time control Whe appears it Fi indicates light controlled on off and when appears it indicates light controlled on time controlled off peee o ate 4 2 interface 4 3 Day and night identification Page 4 of 11 It is night if the photocell voltage exceeds the light controlled on voltage can be set
5. aT R LC POWE AL NU MA ER US LCWS B brid r ty k Wind Sola nd Buc sta Boo Table of Contents l Product OVGPVICW iccecccsstccenentcatccaccsacangcentereccutcnaneadiatntasasateceeeesbeneeenceenetddacadacatutananensenecnits 1 Il Description of MOGGN satis conceececetet gcc aho ots catechol cee 2 Hl Installation SpeciiCallOniaicd4 nia ea ee 3 IV LCD Operation and Display INStructions ccc ccecceceeceeeeeeeeeeeeseeeeeeeeeseeeeneeeeseeeneeees 3 A1 Descrption Of KEY Sicissiicisi cei rec ticudicutcelicieutanteeiebeus Uvccerucunccccctiesuunsetusibesceutecndesuciass 3 4 2 Description of display CONTENL 0 ccecce eee ee ceeeeeeeeeeeeeeeeeeseeeeaeseeseeseneaneoneseesaees 3 4 3 Day and night identification ccceeceeeeeeeeeeeseeeeeeseeeeeeeeeneeeesoneeeneeeseeeseeeseneeeenes 4 AA OUI OCC aioe reece tee cakes ca te atest cadence tect Ea a E a a aaa 5 4 5 Instructions for Control panel cccccceeceeeeeeceeceeseeeeeeeeeeeeeeneceesaesenseesaeseneeeeseees 5 VP FOtCECTION ME CNAMIS iiai a aa a aE aS 9 VI Performance Parameters sisisi inaen aa aaaea narua aana Aa aia 9 VII Common Faults and TroubleShooting cccccccseceeeeeeeeeeseeeeeeeeeeseneneeesenseeeseneeeesenees 10 VIII Warranty and After sale Service ccccscceeeeeeeeeeeeeeeeeeeeeseeeeeseseneeeeseneseneanesenseeesenees 10 Safety Caution 1 Thank you for purchasing our controller Before you install and use
6. f Charge st 1 5 wWwSETH xt ON aya xt Saas DC OUT Fa 4X LOAD 4 5 5 3 Output mode interface of light controlled on time controlled off oe ma xt Charge 1 x BESET on Q ERAH yk DE QUT Fi 4X LOAD The output mode setting of Channel 2 is the same and its interface is as follows 4 5 5 4 Output mode setting interface of Channel 2 load HE Charge 4 xt 2 Jf wKSETH ON 4 5 6 Manual brake operation To ensure the operation safety of wind generator and for the convenience of users this controller is so designed that the wind generator can be braked manually under any state The specific process keep O confirm key on the panel pressed first and then press ESC key gt L and hold for about 5sec Loosen the key to enter manual braking state and there will be Brake displayed at the top right corner of the display interface If you want to quit manual braking state repeat the above operation namely keep gt L and hold for about 5min Loosen the key to quit manual braking state Brake at the top right corner of the display interface will disappear The specific interface is shown as follows 1 Manual braking interface Brake appears at the top right corner of the display interface ARAE y DC OUT TH 4X LOAD It means the wind generator brake when brake appeard here roy a ae AF SSS tion xx Charge DC OUT 1 7 UES ET Hf ee te ON
7. ing sequence 1 Open the package to confirm that the equipment is not damaged in transportation 2 Connect the DC load to DC OUTPUT terminal The loads of two channels share the same anode Connect the first channel load to and 1 of DC OUTPUT and the second channel load to and 2 of DC OUTPUT 3 Connect the storage battery to the BATTERY terminal of back panel of equipment with the cable with copper conductor of 6mm2 and above A reverse connection between anode and cathode of the storage batteries is forbidden in order to avoid damaging components 4 When wind generator is under static or low speed running status no wind connect the wind generator output line to the WIND INPUT terminal of back panel of equipment 5 Shield and then connect the solar cell panel to the SOLAR INPUT terminal of back panel of equipment according to anode and cathode Page 2 of 11 6 Set corresponding parameters to select the load output mode via the keys on the controller s LCD IV LCD Operation and Display Instructions Diagram of panel keys 4 1 Description of keys Symbol Function description Add or display the next value if under browsing status press it to switch to next parameter display if under setting status press it to add the current parameter value modified Reduce or display the previous value if under browsing status press it to switch to previous parameter display if under setting status press
8. k 0 00W in the picture shows the current voltage of solar PV Press A to enter into D load parameter status and the current of DC load can be viewed 4 5 4 Operating parameter state of load 4 5 4 1 View the current of DC load x TE Evin 08 Charge DC OUT Oh AX xt 0 00 LOAD So far the operating parameters of various parts of the system have been all viewed if vou need to look back certain parameter press F to display parameters counter cyclically In this interface as shown in Fig 4 5 4 1 press to enter into output mode setting of Channel 1 and 2 DC load 4 5 5 DC load output mode setting interface lt ie x Charge DC OUT 1 j Sh BY ON LOAD In this Manual Channel 1 load is used as an example and its setting process is stated 4 5 5 1 Normally open mode interface nE n 08 a yi Charge DC OUT 13 ri Ge BX ON A LOAD In this interface as shown in Fig 4 5 5 1 press and the Channel 1 or 2 load setting interface can be switched over For each channel press O set confirm key first and the screen will display a SET sign and then press hA or A annel 1 load can be switched over among the three output modes normally open light controlled on off light controlled on time controlled off Users only need to select the mode they need and then press to confirm and press gt L ESC key to save and quit Page 7 of 11 4 5 5 2 Output mode interface of light controlled on of
9. ontroller is too high and the over temperature protection the wind The output is normal but it is not acer generator brakes the photocell has open circuit but the output will not be affected When charging the temperature decreases to recovery temperature the system will recover Vill Warranty and Services After sale The quality warranty period is one year in agreed warranty period stipulated in the contract if found defective or faulty the company provides free Page 10 of 11 repair service contact the service department of the company or related business 2 the scope of protection of this warranty does not include damage due to external factors such as accidents natural disasters and other force majeure damage not in accordance with product specifications improper use negligence alteration repair improper installation testing inappropriate improper transport Page 11 of 11
10. rator RE msec se Charge DC OUT JXL ASL te poo Y WNb Page 5 of 11 0 00V in the picture shows the current voltage of wind generator Press to enter into next parameter state and the current of wind generator can be viewed 4 5 2 3 View the current of wind generator A nE Eid yt Charge DC OUT JXL AIL xt 0 00 MIND 0 00A in the picture shows the current of wind generator Press A to enter into next parameter state and the current power of wind generator can be viewed 4 5 2 4 View the power of wind generator 4 5 ERAH aye q M Charge DC OUT JKL ATL xt 0 00 WIND 0 00W in the picture shows the current power of wind generator Press A solar PV parameter state and the current voltage current and power of solar PV can be viewed 4 5 3 Operating parameter state of solar PV module 4 5 3 1 View the voltage of solar PV nE HMH h SOs Charge DC OUT JG He 7th xt 0 00 ii 0 00V in the picture shows the current voltage of solar PV Press A to enter into the next parameter state and the current of solar PV can be viewed 4 5 3 2 View the current of solar PV 9 88 fy wee g ae DC OUT JG Fa MB xt 0 00 ae 0 00A in the picture shows the current voltage of solar PV Press A to enter into the next parameter state and the current power of solar PV can be viewed Page 6 of 11 4 5 3 3 View the power of solar PV 4 zB ERAH x Charge DC OUT J As Yb xt 0 00 i
11. t battery power fan speed fan voltage fan current fan power channel 1 output mode and it s on off time Channel 2 output mode and it s on off time light control on off voltage points day or night indicator battery charge status load status as well as over voltage under voltage overload short circuit fault condition The project can be set Channel 1 output mode and it s on off time points Channel 2 output mode and it s on off time voltage points for light control on and off 1 6 Unique solar charging circuit low loss low heat Open way to unload effectively extending the life of the solar battery 1 7 Complete safety protection functions including solar cell reverse charging prevention protection solar cell reverse connection prevention protection solar cell current limiting protection storage battery over charging over discharging protection storage battery open circuit protection storage battery reverse connection prevention protection overload short circuit protection lightning protection wind generator current limiting protection wind generator over speed protection automatic and manual brake protection of wind generator controller temperature monitoring over heat protection CAE A A SEE JEE JEE EE JEE SE A E load over voltage protection XNote Except for storage battery reverse connection prevention protection other protections above won t damage the components 1 8 High quality aluminum alloy case good hea
12. t dissipation performance 1 9 Quality industrial grade components strict manufacturing process in the cold hot humid environment for a long time reliable operation II Description of Model t MAO D4 DO Output terminal connection diagram of LCWS Bx wind solar hybrid controller with double channel standard configuration Page 1 of 11 ge wile it Output terminal connection diagram of LCWS Bx wind solar hybrid controller with single channel dimming signal optional DC OUTPUT Controller 2 Controller 1 Rs485 explanation i i Computer Rs485 interface cathode GND Description Each controller is provided with a RS485 communication port When two controllers are connected they shall be connected in a way of anode to anode cathode to cathode and GND to GND and finally connected to the RS485 port behind the computer via the third RS485 DOr arc and the like Connection diagram of LCWS Bx wind solar f er with communication port RS 485 optional Dimmer port and communication port RS485 are optional so the customer shall clearly specify what you need otherwise we will deliver the one in standard configuration After the parts of wind solar hybrid generator system and photovoltaic panel are installed and external circuit construction is completed it is required to connect and operate the system parts safely and reliably according to the follow
13. the product please carefully read the User s Manual and properly keep it 2 The controller shall be installed by an experienced technician in strict accordance with the User s Manual to guarantee that it can work normally 3 Keep the product free of contact with corrosive gas and humid environment for a long time 4 Be sure not to place the product at a place where it is exposed to humidity rain sun severe dust vibration corrosion or strong electromagnetic interference 5 Please don t open the product s casing to repair it by yourself I Product Overview 1 1 PWM charging ways voltage limited and current limited charging pattern which can effectively prolong the storage batteries service life 1 2 The controller is provided with an accurate rotating speed measuring and controlling module can control the fan speeds precisely 1 3 Two 10A DC output channels three output control modes for each DC output constant on light control on light control off light control on and time control off 1 4 MPPT function with innovative maximum power point tracking technology this controller can greatly improve the charging efficiency by more than two times at maximum compared with traditional controllers 1 5 The controller is provided with a customized LCD display so the user can easily check and set the status of controller via the human computer interaction interface You can view the project there battery voltage battery curren
14. y disable wind testing module generator and photocell input but the output will not be affected Temperature decreases to Over temperature protection is freed and the system recovers to normal safe temperature state This controller has good heat dissipation measures and the over temperature protection module will not be enabled under non extreme cases Page 9 of 11 VI Performance Parameters 20 50 35 85 no condensation 190 5 150 85 5mm Package size S Package size 233 182 130mm about2 2Ko VII Common Faults and Troubleshooting If the above statements are not satisfied or there is any abnormal phenomenon and the controller cannot return to normal please contact the after sale service or business personnel of our company for maintenance or replacement in a timely manner Storage battery box L flickers and It is over discharged The storage battery is emptied Please fully charge the storage battery there is no output before use The system detected output overload and will close one channel but keep another normal Load icon flickers and there is no one Please check the loads and remove Superfluous and not normal loads Press Esc to output recover The system detected output short circuit and will close one output channel and keep normal is on and there is no output one Please check the loads and connection lines After troubleshooting press Esc to recover The temperature of the c
Download Pdf Manuals
Related Search
Related Contents
Kleinkrantechnik Small Crane Technology - STAHL dreamGEAR Prime SABRE™ Ranger User`s Guide - GlobalCom Satellite Communication Philips InstantCare Pressurised steam generator GC7542/02 User Manual 3`` Quad Monoblock BOP OPS-5424 Welch Allyn Connex Vital Signs Monitor 6000 Module Replacement Extron Control App User Guide 取扱説明書 PDFダウンロード Copyright © All rights reserved.