Home
Cube Leaflet - Getting Started leaflet (ENG)
Contents
1. max 250 m Range indoor 30 50 m WiFi options Avisaro AG May 2014 check for updates of this leaflet www avisaro com en 20 data logger documents html cube leaflet Pin Layout for RS232 Interface A weather and dust resistant cable feeder lead to a screw terminal layouted as follows 1 Signal Ground GND 2 Internal use 3 Clear To Send CTS Client is ready 4 Request To Send RTS Avisaro has data 5 Receive RxD Data going to Avisaro Box 6 Transmit TxD Data going to device 7 Supply Voltage 6 32V 8 Supply Ground GND for customized product versions DIP Switches 1 not used 2 On switch on RS232 3 Off switch off CAN Pin Layout for CAN Interface A weather and dust resistant cable feeder lead to a screw terminal designed as follows 1 Signal Ground GND 2 Internal use 3 Not used leave unconnected 4 CAN L Low 5 CAN H High 6 Not used leave unconnected 7 Supply Voltage 6 32V 8 Supply Ground GND for customized product versions DIP Switches 1 1 CAN Terminating Resistor 2 Off switch off RS232 3 On switch on CAN sZ avisaro industrial information technology Pin Layout for RS485 Interface A weather and dust resistant cable feeder lead toa screw terminal designed as follows 1 Signal Ground GND 2 Internal use 3 Not used leave unconnected 4 RS485 Signal B 5 RS485 Signal A 6 Not used leave unconnected
2. 7 Supply Voltage 6 32V 8 Supply Ground GND for customized product versions DIP Switches 1 RS485 Terminating Resistor 2 Not used leave in position 3 Not used leave in position Mechanical data Dimensions 98 x 64 x 34 mm Max Temperature 30 C 85 C Protection class of the box IP66 dust weather 86 a a a G F Hort ort SAn nET nr FT a Contact Avisaro AG Grosser Kolonnenweg 18 D1 30163 Hannover Germany Tel 49 0 511 780 93 90 Fax 49 0 511 353 196 24 E Mail info avisaro com Web www avisaro com Avisaro AG May 2014 check for updates of this leaflet www avisaro com en 20 data logger documents html cube leaflet
3. protection power fail save option Buffering time for real time clock appr 1 month charging time appr 48h CAN Interface default setting Baud rate 125 kbits s RS232 RS485 Interface default settings Baud rate 9600 kbits s No of bits 8 Parity bits none Stop bits 1 Flow control none WiFi specification for products with WiFi option Devices with WLAN trailer can be controlled by an administrator webpage To open it follow the steps 1 Power up the device box and connect your computer with the WLAN SSID Avisaro Channel 11 Mode adhoc without Access Point Encryption none In selected cases of a client specific configuration you might find different WLAN settings on the delivery sheet Make sure that your computer is not connected to any other WLAN or LAN network The Avisaro cube has a DHCP server and will automatically assign an IP address to your computer If you post an address manually make sure that it is in the same address range 2 Open any browser and call the IP 192 168 0 74 In selected cases like a data bridge with two devices you might find different IP addresses for the boxes on the delivery sheet 3 Log in with the user name admin and the initial password 1234 For security reasons change the password Attention take care of the new login parameter Lost passwords cannot be replaced and the box has to be sent in to Avisaro WLAN 802 11 b g WPA WEP Range outdoor
4. sZ avisaro industrial information technology Avisaro Cube Initial start up information Bringing Avisaro Cube Data Logger and WiFi Devices successfully into service The Avisaro Cube is basically ready to use an initial application script is installed and interface settings are set to commonly used values Please note The product is designed for professional use and technical personal only For commissioning connect the screw terminal inside the cube with data source and power power supply 6 V 32 V Please pay attention to the correct connection according to the pin layout Initial operation is usually possible out of the box Check the User Manual online available for instructions on how to configure baudrate or other settings Further documentation e User Manual available in German and English Contains all the documentation for day to day use configuration reset procedures etc e Technical User Manual available in English Detailed description of interfaces timings and programming concepts e Command Interface Guide available in English All commands for the command interface e Scripting Manual available in English Details of programming the Avisaro devices The manuals are posted on the website www avisaro com or www avisaro de in the Support area of the product category Power supply Supply voltage 6V 32V consumption 0 5 to 2 W depending on product options reverse
Download Pdf Manuals
Related Search
Related Contents
SHIBAURA TICKET VENDING MACHINE - B-PAS Stanley Black & Decker HD45 User's Manual Operators manual optris PI NetBox - E2013-01-A OR 52 5 OR 52 6 User`s Manual dyna-wave® centrifugal pump with integral trap SERVICE MANUAL MUCF-A18WV - MUCF A0620140 Meteor-140W Underwater Pool Light Operating Instructions Journal MAJ n° 0 - ANEF Copyright © All rights reserved.
Failed to retrieve file