Home
3SHAPE CONVINCE™ STANDARD Complete Guide
Contents
1. The 3Shape scanner has three axes allowing you three degrees of freedom to move rotate and swing the loaded part in relation to the scanning head You can adjust the positions of all axes within their allowed range in the virtual scanner For every position the software calculates how the laser beam intersects with the reference model and which parts of the intersecting line are visible by one or two of the cameras on the scanning head Only points visible by both cameras are considered during the scanning 7 Rotation 2 Swing 3 Linear To create a scan program do the following 1 Open the Define scan program section In the Scan Planning and Execution window unfold the Define scan program section Set from view checkbox allows you to lock the position of the scanner at your viewing angle Check this box if you want the scanner to see what your eyes see TIP This is especially useful to re scan areas where there are holes Please see more details on how to add new scan lines to cover holes in the Scan Execution section 2 Choose the Linear position type Select the Linear position type e Auto Automatically sets start and end positions for scanning Use the Swing and Rotation edit boxes to define the position of scanner The precision of the scan can be set in the Resolution edit box Rotation steps edit box allows to set the number of lines in the scan program Each line will have the same parameters e Custom Al
2. 3SHAPE CONVINCE STANDARD Complete Guide CO S 1 4 2 8 A EN TABLE OF CONTENTS o irs ds vetou ova ce wa he dec ba oe ead aan lov ee saa ial cu Sb Saad aioe aa wa as dey Sagas edn va ov aN aaa eos la NN 3 MIN VS Ue Ia e QUIENES e eae ee eta gece ae hae el eee RE AS ceca incase 3 A GA A a Slee tant oo 4 2 RETETENCE OPEratlO NS aesa o da el tose 5 EO o A O A enreere ye 5 A RO EO eS TO ne eT ee ee ae ee eee 6 PARTON GTS A O VS eee eee FUE ee errs Pete In PONENT Hee WES EPG O myer Cee yy wee 6 O O NEG E A E ed ie 7 CRE E A EE E e REPPE AE PEPE E ATE EE EE PT A TE lleida A ATAA A AE EE EA T 7 Saat els EE e E E E AT E ERE E me ON A I Mee E AEAN A L AN T N A E N T E T E AN EAN E ES ET 7 AA AAA A T 8 32 QUIE SCOUT io a A A a a oct dabas 8 SU ES N eRT Ma NS E E T O 9 AAA E o sc tsa RON 9 SO CM A aa can E deg ts a NN 10 ER Ne OIG A RO 15 BZD IMP Scan Pla COMEN Vera saa venation evita e da a Mite ad T A AAA A a TT 15 Bi ZO FO VGN COC SS TUN intros to a A be le eal IE li cu Aden bn E le att ca a cada A kde aint nd gud an Sed aes 16 SL tl SAVE CODY Ol Orcos E aos E fasten A E uta act tect oa Mit cae maar ae abet bet cha heats EN N ta an a eat A AA A ad 17 e CA o O 17 Arhandalinaithe Scan a a a SN a le a 18 ATA E E LEANA A AES eat died TAE AAE AEA 18 AAA SCAM O al Re PERE A a eh at ila eten eae 19 Ao REg ter canto Me REIS VIO CI sa sez ei aida 19 AON AUTO a O ES E IS AS TS AE RI ET A ARIS i et AS E a es A E AE 19 a S214 3 A OE nr A A A A A A E
3. Offset mm lt P ogo Rotation 0 00 j HK detete Pm y RR el Measuring in mm Q P 1 2D mode toolbar 4 2D cross section model 2 Plane Control window 5 Views toolbar 3 3D preview window 1 2D mode toolbar Turn on off the 2D mode by clicking Open close the Plane Control window by selecting 2 Plane Control window Turn on off the 2D mode by clicking Open close the Plane Control window by selecting e The position of the cross section plane is changed by dragging the Offset sliding bar or it can be changed manually by clicking the value e You can Sw tch direction of the cross section plane or set it manually in the Rotation edit box e You can turn OFF the 2D mode reset copy or delete the action 3 3D preview window You can observe the location and orientation of the cross section relative to the full 3D model in the 2D measurement plane preview window It is possible zoom the model in the preview window The size of the preview window can be changed by dragging it up down and left right A ee ee Ne ee 43 2D measurements plane by cut 1 Open the 2D measurement plane by cut option Open the right click menu on the selected surface and select the Cross sections gt 2D measurements plane by cut button 2 Create a 2D plane Draw a red dashed line across the reference model where you want to make a 2D plane by holding the left mouse button pressed A 2D measurement plane cut
4. 0 4 Step 2 0 1 Point quality Set to Defaults calculation time You can achieve a similar effect by clicking Optimize more than once When the reference model deviates significantly from the scan it can be a good idea to decrease the threshold distance Internally the optimization uses two steps and the second step must use a finer threshold Ignore distances greater than fields The smaller the thresholds the fewer points get evaluated and thus the faster is the alignment Point quality slide bar allows to adjust the selection of points taken into consideration during the registration Click Set to Defaults to reset the settings 5 REPORT Convince Standard allows you to create inspection reports and save them automatically on your computer in the pdf file format To generate a report from the main window of the program while the project is open you can perform one of the following actions Go to the Main Menu and select Measure gt Generate Report l File View Scanning Measure Difference Map Help Generate Report OR Go to the Inspect tool and select Generate Report Selecting the Generate Report option will display the Report Settings window with two tabs General left image and Difference map right image Select the items you would like to include in the report and click OK 22 Difference Map Project Info Show Current View Persistent Views E r Front View all Rear View al E Left Vi
5. the Mo dongle updates available message will appear A A A A A A A The default license update Server URL can be viewed and tested in the Setup window Click the Test Connection button to verify the connection to the server The Communication Successful message appears as confirmation of a positive result a ll 64 3Shape Dongle Updater Dongle information Setup Server URL ho o E http www 3shape com LicenseM anagement LicenseWebS erver exe soa Use proxy server Langauge English Client version 1 1 17 0 Internet update Manual update Test connection 3Shape A S Holmens Kanal 7 DK 1060 Copenhagen K Denmark Phone 45 70 27 26 20 Technology designed the way you work 3Shape Inc 571 Central Ave Suite 109 New Providence New Jersey 07974 USA Phone 1 908 867 0144 3Shape Asia Room 906 Building A of Eton Plaza No 69 Dongfang Road 200120 Shanghai China Phone 86 21 5835 2281 3shape com S v edeyse O muBuiAdo zlog leniqay
6. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1 1 1 5 1 5 ca 5 The 3D Scene Allows you to navigate in the 3D scene with the mouse or using the keyboard as described in details in chapter The 3D Scene 6 The Features toolbar Contains the options for editing aligning etc the model Inspect Allows you to create and edit measurements When selected displays the balloon with two options Difference Map and Generate Report see the section Difference Map and Offset scale scan Adds removes an equal amount of data to from the entire scan making up for the scan spray or polishing see the section Offset scalescan AAA AA A A A A A A A PS Register Allows you to register a scan to a reference model see the section Register Scan to a reference model 7 The Right Click Menu Right click on the selected reference model element to open the popup menu and choose the desired annotation that will be reflected on the model or the screen see the section Right Click Menu 8 The Views It is possible to create and switch between several views of the 3D scene which helps to better organize the inspection see the section Views 12 1 3D SCENE In the 3D scene you can navigate either with the mouse or the keyboard Action Keyboard otate model Move with the right button down Arrow keys CTRL Move with the wheel down Arrow keys ALT oom in out Rotate the wheel Arr
7. Automatic Optimize AAA a aa a aa a A Note that computing the score can be slow so you may only want to enable it when making final adjustments You can load and save a transformation to a file This will be useful if you use a fixture with reproducible multiple positions like a mechanism to flip the part If you have such a fixture you can calibrate its transforms by scanning a known object in each position and using the above registration methods Once satisfied save the transform action In that case when scanning other objects you can use the same transform action again 21 4 3 6 SETTINGS The registration is computationally extensive Therefore by default only a representative portion of all scan points is used in the calculation In almost all cases this will work fine You can however force how many points should be evaluated Evaluate one point out of checkbox In the extreme you can evaluate all i e 1 point out of 1 Select the Use weight by facet area checkbox to minimize the points density drawbacks Use this option if point density varies a lot in different parts of a scan The number of iterations determines the precision of the final alignment The default value generally works fine but you may gain a little by increasing it This means that will increase Manual Ae Points gt ROI y Settings Use weight by facet area Evaluate one point out of 10 Iterations 25 Ignore distances greater than Step 1
8. E A E N AR AT EE E A EA EE E OD ERN 40 A ey E E RR O ere eel eens ae 40 feo S10 Gs Glo A Te AOE EE TEA OEE PE A EE O E EE E E TEE O E A A ON O OE OEE ES 41 Aone D ADISI E O EE AE ASEE AEE EAEE 41 9 Cross SectionS rider daid 42 SO iCreating 2D Measurement Ra SA AAA AA AA AA AAA ADA 42 OZ OMNIA NOS AAA vice uate A A II A A E E EA T RE 44 SEGPA ES PON COOL SO A a ef E ss E gcd ede 9 T ANG wads inca dB ed E A 46 AE ZU Font LES LENG Eon ihc edt A decor eesti ve ease aud esto Cc A E TO AAA AAA AR eee 46 E AO A GE ase Dc eit ata sta oa avs a Des aa ava Lacan a is bse ems bee veto a baci avn Dent wage aes eae Same eae aman einai ameter 47 e KINGS S AD AAA Gait Banca il eee oth spc A IN A AI tabula ele A O 48 ed ALS lt MA e 9 1099410 PORRA CONO O CO A A E EE E EE E AE EEE AE EE dard aiak Deaiton ena cnan E aoa vant ah Oauba ascent wie 48 A A AAA A A A A A E PTA 49 39 CODY 21 Secuonas DAF AO a A A A EA AE A RRE 50 10 Yisuallzation and E Learning TOA Sii A A a A AAA AE iS 50 OSHO LISTO MS SMS ETS ta A ecb let aa dea ect Se Aa tut et ec ik idad 51 TOL2Z Annotation VISIT SCMHIMOS 52 toons eee toe eda el ta eta Lene ain Polen a AS lan ee aC 51 rs ree O ite ct cea ana eee ih au ag al tc i gen Sag eal atc eas a Se Ss Bi a So ha ts Suh ke Sag tees 52 t0A Change Center of ROA OM ces aR ai E T E a alae a E E AE 52 OS Reterence Modely I oci S ii A A a 53 LORS DEEA E ESTEE SS A E A RI ERA AS E E O EEE O AS EENT 53 TT CUS TONS COUT S Meninas tata 53 NZ CO
9. You can adjust the visibility of the reference model by clicking the Change Reference r_ y y 9 g Show Virtual Model Visibility Settings button in the Visualization toolbar and selected the desired im Solid visualization option from available Please see the Scan Visibility Settings section for more E Wire Frame Hide Reference information Semi Transparent uu I It is possible to set the scan visibility by clicking the Change Scan Visibility Settings we e Solid button in the Visualization toolbar and selected the desired visualization option from available Semi Transparent Triangulated gt Point Cloud Hide Scan Solid Semi Transparent Triangulated Point Cloud HideScan 11 CUSTOM SETTINGS MENU The customization of various Convince Standard settings allows you to customize the design and change the default settings to match your needs Go to the Main Menu P gt View gt Options to open the Customization window that includes four tabs with the customizing options a bed Options e Visual Measure e Popup Menu Help Annotations On Top e Advanced Hide Annotations e Reports Show Annotations 5canning Full Screen View el e Visual This tab allows you to customize the visual program settings Color Gradient Background in 3D Scene allows you to make the background of the main window white unselected or grey selected Default Tolerance sets parameters for D
10. all hiur t Picture z Video ee ormpuber EL Local Dik 0 a Local Deck DE File name D se BH Alusppored Comance Project Y Open pa Cancel 33 6 7 REVERTING TO PREVIOUS PROJECT VERSION You have the option to delete the latest version of a project in case something has gone wrong This will revert the active project version to the previous correctly functioning version 1 Go to the Project manager Browse or Recent page select the necessary project right click and choose Revert to previous version from the popup menu Convince 2011 Recer praje Browere Nowe Peje Crd Mi Edit Scanning pen iiir 2 You will get the warning message before deleting the latest version including all scans REN attached to it Select Yes to continue The next time you open Convince the second latest rd View Change tog Delete now the latest will be opened Rod lo prose vere jh Perr 7 STATISTICS PAGE A A A A A A A NEE ENEE EEE The Statistics page allows you to view the history of the scans created for a project and view statistics related to the measurements Convince 2011 Recent Projects Browse Search Crown Unn3 dcm test project Date Created 10 03 2011 11 00 16 A Last Scanned 10 03 2011 11 00 16 J A Total Scans 2 v The statistics page allows you to observe the list of scans and measurements performed in the project Project Statistics x A D Measu
11. click on the 2D Mode om button opens the plane in the 2D mode It is possible to add measurements by right clicking the cross section element of the part similarly to the 3D measurements If the measurements are created while a scan is not loaded they will not be evaluated until a scan is added to the project If the plane is moved the measurements are updated accordingly The annotations are edited similarly to the described in the 3D sections 45 9 3 ANGLE 2D y A click on the 2D Mode al button opens the plane in the 2D mode It is possible to add measurements by right clicking the cross section element of the part similarly to the 3D measurements If the measurements are created while a scan is not loaded they will not be evaluated until a scan is added to the project If the plane is moved the measurements are updated accordingly The annotations are edited similarly to the described in the 3D sections To measure a 2D angle right click the 2D cross section line of your model and select Dimensions y gt Angle 2D Lo To place the first point then indicate 3 more points to form the angle with two lines The measurement can be edited by dragging the points with the cursor Angle 2D 1 238 221 0 100 9 4 2D POINT DISTANCE You can make a 2D Point Distance measurement between any two given points on the model 1 Open the 2D Point Distance option Right click where you wish to place the first poi
12. dcm 2 File name v Save as type DCM 3Shape Compressed dcm z a Hide Folders Cancel The scanner accuracy can be traced by using the special application in the program File gt View Scanning gt 4 Scanner settings Measure gt Plan and execute scanning Help Test Scanner Accuracy 1 Place the test model into the scanner Place the 15 mm wide gauge block into the scanner consult the section Placing an Object into the Scanner to place the block correctly The gauge the block can be acquired by the recommended manufacturer 2 Perform the test scanning Set the test scanning by selecting the Main menu gt Scanner setting gt Test Scanner Accuracy The Test scan accuracy window appears Click the Start test button to begin the process Ps The results of the scanning will be displayed on the screen They will also be saved in the Documentsl38Shape ConvincelAccuracyTest 4 HANDLING THE SCAN 4 1 TRIM A SCAN 1 Open the Trim scan option Click on the 7rim Scan button in the Features toolbar and select the areas on the scan you want to delete please see the section Selection Toolbar to learn about selecting areas 2 Finish the procedure Selection Click OK Y to cut the selected parts of the surface You can always undo your trimming or trim the scan even further by clicking the 7rim Scan button again miA Brush tool Shape O State F ed y Y 3 4 2 OFFSE
13. in ins Position the cursor over the scan right click to open the menu and select Vo ume ef j w gt Scan Volume Measurements 40 F 18 672 ue If the model does not consist of a closed surface the scan volume measurement is estimated based on the convex hull 8 5 SURFACE AREA a The Surface Area option measures surface area of the scan in mm2 or in in2 Position the cursor over the scan right click to open the menu and select Vo ume Pr z Measurements I gt Surface Area By default a complete model is measured however it is possible to customize it with the selection tool so only a user specified part is used Visible Edit Delete Reset Always on top Surface Area 440 407 mm Lock to screen Edit Selection ls Surface Area Measurement Editing selection Selecting new surface area 8 6 3D DISTANCE The 3D Distance measurement is related to the scans It allows you to measure the distance between two points in a direct line 41 To measure a 3D distance point the cursor at the initial point on a scan and right click it to o Ys 3D Point Distance 1 open the menu then select Volume Measurements E gt 3D Point Distance 4 769 0 100 Then you can point the cursor at the second point of interest to create a 3D Point Distance measurement as shown in the image below 3D Point Distance 1 35 217 0 100 Point 1 2 129 3 928 3 212 The coor
14. in application Enter View scan in application Enter Export project to CSV A 8 THE 3D MEASUREMENTS Convince Standard offers both the 3D and 2D measurement tools All measurements are available from the right click context menu 8 1 LIST OF MEASUREMENTS To view the list of measurements performed in the project click on the Show List of Measurements button in the Visualization toolbar The Measurements window opens up with an overview of all your measurements categorized under several tabs ee 36 Right click at a scan to open the popup menu It is possible to perform some actions mentioned above as well as export the project in the csv format View scan in application Enter View measurements Ctrl M View scan in application Enter Export project to CSV All measurements the list of all the measurements grouped by categories Measurements All 3D 2D Group 4 Coordinate Systems Coordinate System Alignment View 1 Coordinate System Alignment View 2 3D measurements the list of measurements performed in 3D 2D measurements the list of measurements performed in 2D plane a Dimension Measurements Group measurements the classification of measurements according to geometric categories Angle 2 View 1 a Color maps Difference map View 1 Left click on the desired measurement to view it on the model in the main window as well as in the View
15. one User management Add user Delete user Change password Click OK to apply changes Login name New User Old password New password e Retype New password e X conc _ Ef oo o re a a a a a a a a A a aa The Project Manager stores all your projects organized by the parts names in the Browse tab Use the Search field in the upper right corner to find the necessary projects Double click the project name e g Crown to edit it using Convince Standard Comino 2011 Proa ien Tt lest project ee a a a For the better organization of your projects you can create folders and drag and drop the necessary projects into those folders To do so click on the New Folder button and enter a name for your new folder in the pop up window AAA A A A AS To create a new project click on the New Project button The program will automatically bring you to the main window of Convince Standard If you click on a folder or a part s name the mport Project button appears in the menu and enables you to import projects to the program in the 3mx file format The project will be automatically opened in Convince Standard and you can save it in the Project Manager if desired Convince 2011 Recent Projects Browse Search A A A LS Mame Date Convince Projects o est_Projec ew Crown Unn20 dcm New Folder a are pticanie emanates 0 03 2011 1
16. or System Customize the look manually in the Main menu gt View gt Options gt Popup menu APP PPP e e PP e e eee eee eee ee ee ee ee ee ee ee ee ee eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee Measure Points P Cross sections F Show Info SL Add note Configure Right click round menu Right click system menu 2 3 ANNOTATIONS Each measurement is visualized by an annotation The Annotation consists of ao 1 A name on top 2 Tolerance 3 Coordinates Unfold the list of coordinates by clicking at the arrow at the bottom of the annotation In order to change the name of the annotation edit the tolerance or coordinates double click Difference 1 the desired area and type the information 0 100 X 2 889 Y 2 560 Z 0 093 Visible Makes the annotation visible or invisible This can also be done via the List of Measurements button in the Visualization toolbar Edit Renames or changes settings in the annotation Delete Removes the annotation Always on top Makes the annotation always appear on top of the model Lock to screen Makes the annotation be locked to the screen Align faced Makes the annotation face the screen Align by X Y Z Aligns the annotation by the corresponding coordinates Copy Copies the annotation Cut Cuts the annotation Visible Edit Delete Always on top Lock to screen Align faced Al
17. temperature and calibration temperature it is a good idea to perform calibration Calibration can be started by pressing the Calibrate Scanner button Scanner type Q700 Serial number b0850214b Calibrate Scanner Calibrated 28 days ago Scanner temperature 26 0 C Calibration temperature 25 3 C shut Down On starting the calibration make sure that you have the necessary calibrating equipment which depends on the type of a scanner you are using Q800 Q740 comes with only one calibrating object a dot plate Q700 comes with one or two calibrating objects depending on the version Follow the Calibration Wizard when it appears and when done you are ready to scan 3 2 2 2 PLACING AN OBJECT INTO THE SCANNER The object you wish to scan should be placed on one of the enclosed base plates The part should be firmly placed at the center of the plate so it doesn t move during the scanning A general purpose material for fixing a part is BluTac a kind of modeling clay Its disadvantage is that a rather large section of the part gets buried into the clay so a custom made fixture may be preferable If a part to be scanned has shiny surfaces or is translucent it has to be sprayed with 3D scan spray to make it matte Only matte solid parts can be scanned with optical scanners Place the base plate containing the object into the scanner 3 2 2 3 SCANNING ON A NETWORK COMPUTER It has been assumed so far that the sca
18. to create a new user Login when you have an account Type in your user name password and then click the Login button Create import or edit the project The Convince Project Manager window loads after login The Project Manager displays a list of Recent Projects providing an easy access to them There you can edit import existing or create a new project gt 3Shape Convince New project You can load reference files of the following formats ASC DCM DXF NMS STL PTA PTS points WRL and VRML Addie Debba Change pudor few user detads Liege rare Posed Paya E tuderirastrabor righba Convince 2071 1 Edit project 2 Import project 3 New project 1 Project manager Ctrl E 2 Save project Ctrl C 3 Load reference 4 Load scan 5 Open scan mode Ctrl Enter 6 View scenes 7 Add new view Ctrl Insert 8 Visualization options 9 Main menu 6 Load Scan p gt 3Shape Convince Crown Unn3 dcm test 1 Crown Unn3 dcm You can load scan files of the following formats STL DCM PTS points STL ASCII WRL and VRML NMS The measurements menu can be toggled between two modes The System Menu and the Round Menu 2 selected in the Main Menu gt View gt Options gt Popup Menu tab A number of scenes can be saved on the left of the window to help you organize your measurements 1 while the instruments at the bottom 4 allow i i a Measuring in mm you t
19. to missing scan dataj il Signifies whether the report was created for this project version Default Indicates the scan version that is opened in the edit mode 35 You can select the desired scan with the left click and choose then the following options Gives you more detailed information on the measurements on the selected scan Measurement Results Scan 6 hal pa Created 10 03 2011 16 39 05 Type Caption Nominal Tolerance Measurement Points Used Points Total Result Point Difference Difference 1 0 000 0 100 Mot evaluated METEN a z er PE ES OE HEARD ears ES Saar a Remove Allows you to delete the selected scan a a A A A A A A A A A A Generate report for selected scans Allows you to create the report for the selected scan and saves it automatically to your computer in the pdf file format see the Report section I If you want to open up an old scan in the most recent project version click the Reevaluate button In this case the clock symbol I wil disappear from the table This symbol appears when the measurements of the given scan are outdated since there exists the most recent version of the project where the measurements can be more correct So you can reevaluate the given scan with a more recent project version Right click at a scan to open the popup menu It is possible to perform some actions mentioned above as well as export the project in the csv format View measurements Ctrl M View scan
20. 00 16 A ld ka Total Scams 2 This is what the report looks like after you have generated it for the first time E Shen ap Cia 3Shape Convince 2011 Inspection Report MM 201 3shape gt Current Page No i Total Page Mo 2 Loom lector 105 The corresponding icons in the Statistics page indicate projects with already generated reports Y ID Project Version Created Evaluation Passed Fail Missed Fi EEA An PA ae NA UA Y 2 2 10 03 2011 11 00 1 Passed o o 0 View the Report section for the description of report settings 32 User Report Default a Po AAA i qcadmin a Y 6 6 EXPORT AND IMPORT To export your project go the Main Menu 2 gt button in the upper left corner of a program gt gt 3shape Convince Crown Unn3 dem te window while the project is open and select File gt Export project to package Je Project Manager File View ist Load Scan This will display a Save Project window see image below Enter a file name and click Save y Save project Your project is now saved in the 3mx file format The Export project option is also available from the right click menu in the Recent page requires version 1 4 0 4 or above Measure gt gt Scanning gt gt gt Help Export project to package Export project data to CSV Save copy of scan Project information Exit AA AAA I AAA AOS J z m i a i
21. 1 02 28 New Project IS Z project_1 EA D 03 2011 11 02 28 Es Crown Unn3 dcm Delete 3 03 2011 12 70 09 T Project_test Cut Ctl X B 03 2011 12 20 10 C test 09 03 2011 14 04 09 27 o j onvince 2011 When you click on the project s name four new options become available Edit Scan Recent Projects Browse v A Statistics Is and Create Report gt Right click on the project s name to get a menu with some additional options See the image to the left Convince Projects i Test_Project Ww Crown Unn20 dcm Cc p 3 3 Crown Unn3 dcm New Project Ctrl N C Project_test Edit Rename C test Copy C test project Scanning Open Scan View Statistics View Change log Delete 6 3 RECENT PAGE The Recent Projects page is the first page to open if you have already created projects in Convince Standard This page displays up to ten recently accessed projects in the program If you are at the Browse page you can always switch to the Recent Projects page and vice versa Convince 2011 Recent Projects Crown Unn3 dcm test project Date Created 10 03 2011 11 00 16 h Last Scanned 10 03 2011 11 00 16 y z I ye Total Scans 2 T Crown Unn3 dcm Project test Date Created 04 03 2011 15 43 04 3 E F A Last Scanned l a Total Scans O T View more information about the options of this page in the section Accessing an Existing Project 6 4 CREATING A
22. 23 11 10 2010 16 51 05 10 03 2011 11 01 44 Restore Ctrl R Del E The first time you log into the program use the credentials given by your provider Remember that the user name and password are case sensitive Username Password After you have logged in the User Management form opens up allowing you to create new users delete them or change your password Admin users only Add user Delete user Change password New user details Login name New User Password Retype Password leticia Y Administrator rights a A ca Add user Type in a new Login name and Password Click OK to apply changes D gt 3Shape Convince Project Manager Close Minimize Log out User Administration Note To be able to edit a project you must have administrator rights So please select the corresponding checkbox in the form to become an Admin The regular User is only allowed to scan projects created by Admin and generate reports but cannot edit them The Admin account also provides an access to the User Administration form in the upper left menu of the main window A AS Delete user Change password Unfold the drop down list in the Delete user tab and select the user whose account you would like to erase Click OK to apply changes Select user to delete nl a el The Change password tab allows you to replace the old password with a new
23. E TE A ER AOR BY I OTR 19 A FOO y O ER a TS TI REIS AE A SA can AT AS ATI AS val we ele tas AS pee cot echt heals 20 LI SO OO ITESO a A DS EAS AS Se as A 20 MS an S TONTA LONAS CONC IS E SA A A i es Sie enter A A ISS E A A EG ach 21 AGO SENS A A A LS A we APR wd acne Dee adm A ip cee ee L E A A 22 BIG DOM cuan a ta nuragiwsesuneies nueva dieeanean a ayauseananoeanaiun acetate nnayiueomanaaaauie daa nanan nna somabaeauacaaeon aS 22 ORO ecuador ios 25 G21 WSer ACCOUNT bs 26 FOS Ss tUCWS iS A A AA A A A A EN A IS tata ba ae 21 o e A nn A IR UR III OE SE 28 SR o Ss A NO 28 COV ACCESSING an EMIS ING PTOS Ci A AA A A A A AA AeA E T cd 29 o o AM A A A eubotacdn amine cauee saa etia oa eaten aca eat anaee 30 SS AA O A Sena a ate che geo E tenes 31 LEIS Ul CS bigs ear ava O mses cnt ec mac care eg Saad ga daa ted deta cee ay asec eae eee eens 32 60 AIRS DOF On Ie PIOC eree aa A A A A A AS a AA A A eo atk 32 O CEPO ana MOPO Cee aee a o E a E E ba a aay ail dar awe eatin st ate a a a Ta aa saan A AA 33 6 7Reverning To Previous Project Verslo vecinos inte EAEE AEAEE DEELEN A tds 34 ri Bn Ee ET EE EE TEE EE ET EE EEE EEE EE ET E EEEE E EES EEE EE ET E E 34 S Ipe SD Measureme NiS iii 36 SO bY Sts ENE e O EO E OE AEA E E AE E A E E O EO T E E OOE E TAT 36 AB ad r r AN 37 S A TOn 2 ai Got Ma Ven a cnr ee E a O adidas 38 Ie e A E A ANE A a A E O Dc cee E ENE EAN E E EEEE 39 8 23 Available Sta SUCIO NOA era E E E ae EO E TE NA 40 ESA FONTON OONO a en o 5
24. NEW PROJECT Perform one of the following actions to create a new project aaa Click the New Project button in the bottom right corner of the Recent Projects page a A A SS SS SS SS SS SS SS A Sn Ss nm Sm et om smn sm sm wl Click the New Project button in the top left corner of the Browse page Convince 2011 Recent Projects Browse B 28 Right click on the project name and select New Project Rew emer Edit Rename Copy Ctrl C Scanning Open Scan View Statistics View Change log Delete Right click on the part name and select New Project The program will open up a new New Project N project with this particular part Rename Delete Cut Ctrl X ee Right click on the folder name and select New Project New Folder New Project Rename Delete Cut Ctrl X It is possible to press Ctrl N to create a new project If you create and save a new project with the part that already exists in the folder the program automatically saves this project to the appropriate section 6 5 ACCESSING AN EXISTING PROJECT You can access and modify the existing projects from the Recent Projects page or the Browse page by clicking on the relevant buttons or right clicking on the project and selecting the options from the menu Convince 2011 Recent Projects Crown Unn3 dcm test project Date Created 10 03 2041 11 00 16 Y T a Last Scanned 10 03 2011 11 00 16 Py oP gt LM Total Sca
25. NVINCE COMPONE US areena O OP PRES TEO aa aa 55 A E DA AAA chee Dar Waa A E ade ota sli A A 58 PA AAA E A E A AAEE RT EE EATE ETATE iio 59 Selection Toca AN SA A ere picada 59 PAS Call ALOU ataron urnas 61 1 INTRODUCTION 3Shape Convince Standard is a Quality Control software for acquiring quality assurance of a part Measuring different characteristics and dimensions of objects and comparing them to the specifications provides the information on whether the product meets the specific requirements With the help of Convince Standard the dimensions and forms of an object are defined and toleranced and all deviations are found 1 1 SYSTEM REQUIREMENTS Please get acquainted with the requirements for this software Minimum CPU Intel Core 2 Duo 2 0GHz or better HDD 80GB or more RAM 2GB or more Graphics OpenGL 2 0 support and at least 512 MB of memory OS Windows XP SP2 SP3 Windows Vista SP1 or Windows 7 x86 Recommended CPU Intel Quad Core 3 0 GHz or better with 12MB Cache or more HDD 250 GB available disk space RAM 4GB RAM DDR3 or better Graphics NIVIDIA GeForce GT220 1GB RAM or better graphics adaptor OS Windows 7 64 bit Load Reference 1 2 QUICK GUIDE Start application Start Convince by clicking the desktop shortcut Login for the first time Create a new account by applying the user name and password case sensitive specified by your provider A User Management form pops up enabling you
26. Rear Left Right Top and Bottom eee ee ee ee e e 1 1 1 1 1 1 1 1 5 1 1 1 1 1 5 1 5 1 1 1 0 1 5 1 1 1 5 1 5 1 1 5 0 5 1 1 1 1 Change Annotation Visibility Settings Provides a list of on off annotation visibility settings Lock Annotations Annotations on Top and Show Hide Annotations fa a a ee a NS ne San RE a A A A E A ES Show Hide Ruler Provides the user with a ruler on the screen which can be moved around to different locations Show Hide Cursor 3D Coordinates Shows the 3D coordinates of a point under the cursor b 57 Show Hide Origin Displays a small coordinate system indicating origin and XYZ axes in the 3D scene ee ee 5 1 1 5 1 5 0 1 0 0 5 1 1 0 1 5 1 5 1 5 1 1 1 5 1 5 1 5 1 5 1 1 1 5 1 1 1 1 5 5 1 0 1 1 0 1 1 1 1 1 1 1 0 0 1 0 0 5 1 1 Change center of rotation Provides the list of the options for specifying the center of rotation for your model Center of mass of Scan Center of mass of a reference model and Center of Coordinate System Change reference model Visibility Settings Provides a list of settings for the visibility of a reference model Show Virtual Solid Semi Transparent Wire Frame and Hide a reference model A A A A A A A A A A A A A Change Scan Visibility Settings Provides a list of settings for the visibility of a scan Solid Semi Transparent Triangulated Point Cloud and Hide Scan Tn a a a ee a ee ee ee 5 a a a 5 5 5 5 5 5 5 5 5
27. SCAN CYLINDER eS al The Scan Cylinder parameters let you set up the scan cylinder Unfold the Define Scan Define Scan Cylinder Cylinder tab to set up the desired parameters The scan cylinder defines the scanning area To achieve faster scanning set the scan cylinder so it fits the objects you wish to scan Scan Cylinder mm Enter the Bottom Top positions and Diameter into the appropriate edit boxes Bottom 5 Top 43 Quick Diam 57 Scan a A A A A A A In the upper right corner of the main window you can see the Display settings menu see the image to the left LE Display scanner Select the Display scan cylinder check box to make the cylinder visible on the screen so you can see it while planning the cylinder size x Display fixing plate X Display scan cylinder A AA A RE A A A A A A A aE eR ER A ED To launch the quick scan press the Quick Scan button This will set the cylinder automatically You can adjust the cylinder manually with the control points on the cylinder see the image bellow or by specifying the parameters in the Scan Cylinder tab Without making a program you can press the Scan button to make a default scan sequence rotating all the way around the object from 6 different rotations in a swing of 45 degrees You can easily create your own scan program which tells the scanner from which angles and positions it should scan thus yielding with the best possible coverage
28. T SCALE SCAN a re a ee ee ee a a O If scan spray has been used on your object you can click the Offset scale scan button in the Features toolbar to add remove an equal amount of data to from the entire scan making up for the scan spray or polishing a ee ee ee a After clicking on the Offset scale scan icon the Offset Surface window opens up offering you to do the following Offset Surface Offset distance 0 e Specify the Offset distance value of the layer thickness to remove from or add to the surface of the scan Remove artifacts after offset e Select the Remove artifacts after offset checkbox to remove possible artifacts appearing when the surface is offset However this option makes calculation slower and is rarely necessary Scale model 0 2 o coma Use Scale model editbox to scale your scan according to the parameters you select 4 3 REGISTER SCAN TO THE REFERENCE MODEL With the Registering Scan to Reference feature you can register the scan to the reference model Registration is a combination of alignment and mapping of each scan point to its closest functional surface on the reference model When this is accomplished all measurements can be evaluated properly Therefore registration is an important step Click the Register button in the Instruments toolbar to start the registration process Register Reference to Scan de Manual Points SO ROL o o eg Manually align the sc
29. a Convince 2010 Ie gt Crowns Premium Posteriors X gt Search P By Organize y 8 Views PB NewFolder Recent Projects Browse E Name Date modified Type Size a E Doamne No items match your search Crown Unn3 dcm_ Testl __ WE Desktop Date Created New Project Ctrl N A E Recent Places Last Scanned Edit li se Computer Total Scans 2 v Scanning E Pictures I Music Open Scan J View Statistics 24 Recently Changed Crown Unr B Searches Date Created Export Project to package N A de Public Last Scanned View Change log O h ye E PR Total Scans 2 Delete v ea Rename File name Save as type Convince project package models included 3mx 3MX M You can also export the project by right clicking it on the entry page and selecting the appropriate option from the drop down menu e Import To import your project perform one of the following actions i Click on the mport Project button in the right bottom corner of the Recent Projects window ee ee 1 S o m a Browse This will display an Open Project window see image below Select the desired 3mx file and click Open The project is now imported into the program and can be saved if desired E Open Project CN d Computer FOR DOCS be mech f 5 F Gngenine Y New folder fi y 24 Recent Places 5 Je tt de biy Documents Ji FICTURE Jl TRANGLE a Libranes i Dak E Document
30. an Trim Align Finalize Rotation 138 92 Rotation steps 6 Execute Scan lp Load 5 Scan Trim Align Finalize Advanced Done Cancel l Load a Advanced Done Cancel 3 2 3 1 PLACING THE REFERENCE MODEL If you have a reference model available you gain further possibilities for planning your scan You need to make an approximate placement of the reference model so it matches the position of the corresponding object in the scanner It is neither possible nor necessary to achieve the exactly the same placement as the software can make small adjustments of your final placement By pressing the Place reference model tab in the Scan Planning and Execution window you can move and rotate the reference model using the mouse or enter a specific translation and rotation in the coordinates edit boxes Scan Planning and Execution Placement 1 1 Define Scan Cylinder Place Reference Model fh Translation Rotation x 0 00 0 00 Y 0 00 0 00 Z 0 00 0 00 A A A A A A A A A A A A A A In the upper right corner of the main window you can see the Display settings menu see the image to the right Display Settings X Display scanner Select the Display fixing plate check box to show a model of the fixing plate on which you object is placed This makes it possible to view how the reference model should be placed X Display fixing plate in order to match the object you are scanning Display scan cylinder 3 2 3 2 ALTERING THE
31. an to the reference model Monng the scan is done chclang and dragono the scan and rotating done by usmg the arrows next to the scan Trardormation and Score Tramtlation 042 13 91 Rotathon Q 0 Show Score For future 3 Load DIG A Austtomatit Oplimaze Reset In the Register Reference to Scan dialog click the Automatic button and wait for the program to align the scan to the model If it fails you can use one of the three methods Manual Points or Region of Interest The Reset button allows you to start the process over 7 Automatic The manual section allows you to perform the manual registration of the scan to the reference model by moving and rotating the scan with the purple control points Manual 4 SP v Automatic Optimize Reset Done Register Reference to Scan o gt Manual Points ROI y Settings Manually align the scan to the reference model Moving the scan is done clicking and dragging the scan and rotating is done by using the arrows next to the scan Tranformation and Score 4 3 3 POINTS a A A A A A A A A A A The points registering is the manual alignment of the scan by selecting three points on the scan and the three corresponding points on the reference model After all the points have been selected the parts are aligned automatically oo Points The points can be set directly on the model and scan or by using the two sub windows that show the parts separ
32. ately This is especially helpful when a reference model and a scan occlude each other You can edit the registration even after the points have been set by dragging any point over the related surface gt 35hape Convince New project Crown Una dd dem OH i de Manual Points age Rot yi Sting ial y Manual align the sean lo the reference model Sehect Ehnes points on the sean and three corresponding peints on the register model Then the scan ell be aligned using theete puma Reset pomis Trantonmaton aed Score r 7 3shape gt Click on the Optimize button to let the software make the final adjustments If you want to start the process over click the Reset button 4 3 4 REGION OF INTERESTS a a a a 5 1 Open the Manual or 3 Points tab Rotate and move the scan so it is close to the reference 2 Open the ROI tab Select the area of interest on the scan marked gt that will be registered to the same area on a reference model View the Selection Toolbar section for the detailed information about the selection tool 3 Finish the procedure Click the Optimize button so that the software can make some final adjustments and align the area you have selected If you want to restart the process click the Reset button The Region of Interest ROI method is used if there is an area on the scan which is of higher importance to be aligned properly 20 Selection Brush tool Shape O 6 mm State Se
33. ay scanner check box you can view the scanners position according x Display scanner to the object while trying different axis positions X Display fixing plate If you have a reference model you can see how a certain setting covers the object you are about to scan You can see which areas will be viewed by both cameras by one camera and by none This is important for a good scan of the area view the section Simulating the Scan X Display scan cylinder 5 Finish the procedure Click the Save button to save the created program The scanning start and end positions are indicated with the blue planes and can be also set by dragging their interactive control points The previously saved scanning programs can be loaded with the LA button 3 2 3 4 SIMULATING THE SCAN You can simulate the entire scanning process by clicking the Simulate scanning of entire program Ni or Simulate scanning of selected line buttons If you have a reference model you are able to see the coverage your scan program gives during scanning There are two colors used to indicate the quality of the expected scan of the model The dark blue indicates the area that will be seen by both cameras while the green color indicates the area is only scanned by one camera This color scheme is intended to help find an optimum angle and direction for the scanning process AS A selected line or the whole program can be deleted from the Scan program list wit
34. bles disables the statistics window see the section Available Statistical Information 8 2 2 WHISKER PLOT You can create a whisker plot on the difference map by clicking the Options button of the Color scale menu and selecting Enable Whisker Plot This creates vectors on the difference map which become larger depending on the deviation between a reference model and a scan Color scale i Opti Show bands Autoscale 0 12 Y Show difference at cursor vV Enable Wisker Plot N ROI difference only Show Whisker Plot Options Y Show Statistics 0 101 0 075 ee ee ee ee e e y The whisker plot can be edited by selecting the Show Whisker Plot Options menu as shown in the image below Map scale factor This enables you to choose a Map Scale Factor which when increasing it makes the difference between the large and small deviations more noticeable You can mark a E Threshold Threshold checkbox so that vectors shown on the difference map are clamped to a certain size To view the gradation in contour lines you need to select Show bands option Show bands Autoscale Show difference at cursor Enable Wisker Plot ROI difference only Show Whisker Plot Options vV Show Statistics 39 8 2 3 AVAILABLE STATISTICAL INFORMATION The Statistics window that appears when the Difference map option is activated shows statistics for the current difference map Points displays the number
35. by either clicking the Change Annotation visibility settings button in the Visualization toolbar or selecting the Main menu gt View and choosing the Show Hide Annotations option in the appeared menu button in the Visualization toolbar shows hides the ee ee ee ee ee ee eel 51 Scanning Measure 1 t minh Pe IS Hide Annotations Show Annotations The image below illustrates a reference model and a scan with measurements when the Show Annotations option is enabled and Annotations On Top is disabled 3D Point Distance 1 6 053 0 100 6 058 dl Difference 1 Surface Area 1 427 967 mm The Lock Annotations option fixates position of the annotations on the screen 10 3 SHOW HIDE RULER You can enable the measurement ruler on the screen by clicking the Show Hide ruler button in the Visualization toolbar A The ruler can be moved with the cursor to a desired position while pressing the left mouse button The ruler scale is updated when the part is zoomed in or out You can change the rotation center of the model by selecting the Change Center of e l gt Center of mass of Scan Rotation f button on the Visualization toolbar This is purely for facilitating your work W Center of mass of Reference with the software it has no impact on any measurement E Center of coordinate system 52 10 5 REFERENCE MODEL VISIBILITY SETTINGS ree a A
36. d a Reference mee Load Scan Loads a scan see more in the section Load a Scan Help ee Save Project Saves the current project di Export project to package Exports the current project in the 3mx file format view more in Export project to package the section Export and Import of Projects Save copy of scan Save copy of scan Saves a copy of the currently used scan in the stl pts nms file formats to the location of your choice Project information Project information Displays information about the current project reference model Scan Exit Created by etc Exit Closes Convince Standard Options Opens the Customization window with options for customizing your program settings view the section Custom Settings Menu Full Screen View Unfolds the main window of Convince Standard to full view File dd a Annotations On Top Fixes the annotation so it is always on top of the model while it is View bo a Options being rotated Scanning Full Screen View Help l Hide Annotation Makes an annotation invisible on the screen view the section Annotation Annotations On Top Visibility Settings Hide Annotations Show Annotations Show Annotation Makes an annotation visible on the screen view the section Annotation Visibility Settings Scanner settings Opens the window with options for setting up a scanner Plan and Execute Scanning Opens the scan planning and execution
37. dinates of the measurement can are updated when on dragging the measurement points over the scan You can edit the label and the values of the coordinates manually by left clicking them with the mouse 9 CROSS SECTIONS 9 1 CREATING 2D MEASUREMENT PLANES A e a MMMM M MM MMMM MMM MM MM M MMM M M MMM M M M M M M M MM M M M M M M MMM M MM M MM M MM M MM MM MM M MM MMMM MM M MM M MMMM MM M MM MMMM MMMM MMMM iMi iii The 2D Measurements Plane is used for creating measurements on a specific cross section of a model oe a a A S S A A S S S S S S A S S A A S S S M S S S S S A S S S S S S S S S S S S S A A S S S S S S S S S S 1 S 5 5 S S S S 1 S S S S S S S S M S A S S S S M 1 S S S S S S 1 5 1 S 1 S 1 S A S 1 A 5 0 O A a a E 1 a m a a a a a ee a e ee a ae Ee 1y 2D measurements plane 1 Open the right click menu on the selected surface and choose the Cross sections gt 2D measurement plane button A 2D measurement plane cuts through the selected surface defined initially by the orientation data contained in the reference model surface Each reference model surface contains its own default location and orientation defining how to initialize a 2D measurement plane 2 Click on the eye symbol in the corner of the 2D plane to open a 2D cross section window as shown on the following image in the Documents 3Shape Convince Accuracy Test 42 gt 3Shape Convince Crown Unn3 dcm test 2 Crown Unn3 dcm Ix Plane Control
38. e preview of the selected scan in the preview window to the right Open Scan x Look in di Premium Posteriors v P DH y T Name Date modified Type Size e D Crown Unn2 dcm Recent Places P gt Crown Unn3 dcm Pb Crown Unn4 dcm w P gt Crown Unn5 dcm gt Crown Unni2 dcm Ba gt Crown Unn13 dcm gt Crown Unn14 dcm gt Crown Unni5 dcm V Bring model to center Pp Crown Unn18 dcm P gt Crown Unn19 dcm gt Crown Unn20 dcm A Pp Crown Unn21 dcm Computer P gt Crown Unn28 dcm File name Crown Unn5 dcm X de Files of type All supported formats y Cancel The supported formats are STL stl Points pts STL ASCII stla VRML wrl wrml and NMS nms You can also open a scan file by dragging it onto the main application window Instead of loading a scan file you can also create a new scan The Convince Standard software is fully integrated with 3Shape s scanner Please see chapter Scanning for more details 3 2 SCANNING Convince Standard provides easy scanning of objects and more advanced settings if needed This section will first present a quick scan guide and then describe the details of scanning for those wishing a more customized scan 3 2 1 QUICK SCAN GUIDE Setup the scanner 1 Connect the scanner to your PC using the enclosed USB cable 2 Turn on scanner using the button on the back of the scanner 3 Turn on the ScanServer by clicking the ScanSer
39. educe point cloud Cluster diameter Min points in cluster sets the number of points in a cluster Min i f Min points in Cluster Final number of points determines the number of points that should be increased or reduced Improve mesh Iterations If this is zero then there is the same number of triangles on corners as well as Final number of points flat surfaces You are making more triangles on corners and less on flat surfaces getting a better distribution of points A Hole closing defines that all holes smaller than this parameter will be closed after triangulation Repair mesh Hole dosing mm Smoothing adds smoothing to the triangulated model mio 3 2 7 SAVE COPY OF SCAN You can save a copy of the scan by selecting the F e gt Save copy of scan from the main menu Here you can select e the folder e the format for the file e the name of the file The supported formats are DCM ASC PTS PTA STL ASCLL VRLM Save As x 9 m gt Crowns Premium Posteriors v 4 Search P By A IC EE Name Date modified Type Size F AA b gt Crown Unn2 dcm ME Deskt D Crown Unn3 dcm eskto P D gt Crown Unn4 dcm ia ra P gt Crown Unn5 dcm 1 Computer Pb Crown Unn12 dcm F Pictures P gt Crown Unn13 dcm BP Music P gt Crown Unn14 dcm 44 Recently Changed P gt Crown Unn15 dcm P Searches D Crown Unn18 dcm y Public Pb Crown Unn19 dcm D Crown Unn20 dcm Folders a Crown Unn21
40. er or from the Statistics page 24 6 PROJECT MANAGER The 3Shape Convince Standard Project Manager provides you with options for working with recent projects and creating new ones browsing through the existing projects and creating new folders The image below illustrates the main window of the Project Manager gt 3Shape Convince Project Manager Convince 2011 Recent Projects Browse Crown Unn20 dcm project 1 Date Created 10 03 2011 1102 2 Aj 3 A ast Scanned 10 03 2011 11 02 34 J 4 gt li rn total Scans 1 v Crown Unn3 dem test Date Created 10 03 2011 11 00 42 A Last Scanned J e lu xe Total Scans 0 Y ate Created 10 0 11 11 00 16 A A a otal Scans Y Crown Unn3 dcm Project test Date Created 04 03 2011 15 43 04 Y a A Last Scanned y LE hi xe Total Scans v The Project Manager contains two tabs that are described in details in the next chapters e The Recent Projects tab that allows you to work with the recently accessed projects e The Browse tab that allows you to find the desired projects in the list of the all existing ones and the New project buttons to import and create projects respectively Use the Search filed in the upper right corner to find the necessary projects Click the Garbage Can button to view its content Right click on the necessary item to Restore or Delete it 25 Garbage Can al Created Deleted 10 03 2011 11 01 22 11 10 2010 17 02 23 10 03 2011 11 01
41. ew Y Right View hag Top View ing Bottom View Before generating your report you can go to File gt Project information and fill out the blank fields with the additional information See the image to the left File Po Project Manager View Load Scan Save project This data will be included into the report Scanning Measure Help Export project to package Export project data to CSV Save copy of scan Exit Approved by Aena Comments It is possible to select a logo image for your report To do this go to Fi e gt Options and select the Options tab Scanning Full Screen View Measure Annotations On Top m _ _ _ A A Click the Load image button to open the desired illustration Click OK when finished You can select logo image to show it in report 3shape gt After all the required information has been entered you can generate your report The report viewer starts up in a separate window The first time you start it the initialization can take a moment The image below shows the example of a generated report with the logo image project information etc E 3Shape Convince 2011 Inspection Report 10 March 2011 3shape Part Crown Unn3 dcm Project test project v1 ID 17 Total Page No 2 Zoom Factor 100 You can also generate a report directly from the Project manag
42. h the by clicking the corresponding buttons 3 2 4 SCAN EXECUTION Before starting the scanning process make sure your scanner is connected to the computer the ScanServer is ON and your object is in the scanner See Setting up the Scanner section The door of the scanner should be closed before beginning the scan To begin the scanning press the Scan button located in the Scan Planning and Execution dialog As the scan program is executed you see the 3D points come in They are shown as a raw surface The final scan model is created under the Finalize step Execute Scan m 4 gt a Scan Trim Align Finalize l Load y Save Xx t 25 Advanced Done Cancel If you are not satisfied with the scan you can make changes to the scan planning and then click the Aescan button and start over It is possible to scan the newly added lines only To do that add the necessary subscans and click the Scan newly created lines only button appears under the Scan button This allows to save considerable time as you do not have to rescan the entire program Once you have completed the scan process click the Finalize button to generate the final scan model The raw scans are converted to a triangulated surface during this step When you click the Done button all steps in the Convince Standard workflow are executed as if you had loaded a scan as an stl file registration of a point cloud and the reference model mapping of the
43. ign by Y Align by Z Copy Cut 2 4 VIEWS a a ee a a A In Convince Standard it is possible to create several views in the special Views toolbar located in the left part of a main program window Each view contains the same object but with its own set of measurements and visualization attributes e g viewing direction You can use different views for each area you wish to focus on When making the final report each view will get a separate page displaying the results There is only one view by default but you can easily add more by pressing Add new view Ns Create New Blank View Ctrl Insert y or right clicking on the view tab and choosing Create New Blank View You can also Delete View Ctrl Delete delete or rename the view with the help of a right click menu Rename To switch between the views click on them directly or use the keys CTRL PgUp and CTRL PgDn When the list of views is too long the Next Previous button appears becomes blue when highlighted so you can scroll up and down to see all the views Click on the grey border line becomes thick when highlighted and drag it sideways to change the size of the views windows 3 GENERATE A SCAN You can load an existing scan or generate a new one with a 3Shape scanner es When you click on the Open Scan button in the Main toolbar to open a dialog from which you can load the scan file Select the desired scan and click Open You can see th
44. imensions Size and other measurements Measurement Annotation Font Size allows you to set the font size for annotations Diff map max value defines the max scaling value for the Difference map Diff map min value defines the min scaling value for the Difference map Measurement Arrow Size drag the slide bar to change the size of the measurement arrows The Reset to Defaults button resets all the settings in the menu to the default ones e Popup menu This tab allows you to choose between the Round and the System menu types e Advanced Options Visual Popup Menu Advanced Options Color Gradient Background in 3D Scene Default Tolerance Measurement Size Annotation Font Size Difference map max value Difference map min value Measurement Arrow Size Reset to Defaults E Options Visual Popup Menu Advanced Options Menu type Round menu Options This tab allows you to customize the additional features of the program Visual Popup Menu Advanced Options Delete old raw scan data DCM files mark this checkbox if you want to automatically delete the raw scan data that is older than the amount of days specified in More than days ago Select the Created or Accessed radio button to delete the data that was either created or accessed more than the specified amount of days ago Display language allows you to select the language for the program Units system al
45. lect visible gt Select an area which is of particular interest to be E Ey G J Y aligned properly If no area is selected the whole q model will be atempted to be aligned in the best possible way Register Reference to Scan d Manual Points eg ROI Y Settings Tranformation and Score ZA in v Automatic Optimize Reset Done Selection Register Reference to Scan Manual rn Points a ROI Y Settings pe as A neue Brush tool Shape O 06 mm State a Select visible gt ee E 4 Select an area which is of particular interest to be SY y O 3 Y aligned properly If no area is selected the whole model will be atempted to be aligned in the best possible way Tranformation and Score Automatic Optimize Reset Done 4 3 5 TRANSFORMATION AND SCORE In the Transformation and Score section you can follow the result of the above registration Tranformation and Score methods as the numeric values of translation and rotation of the scan You can also actively change these values and thereby determine the registration as well aos p i Rotation 0 To monitor the effect of such adjustments check the Show Score option The dialog then Show Score shows the sum of squared distances average Ideally this score should be at its minimum For fixture 7 for an optimal registration It may be justified to accept a higher score though when you decide that some scan points are outliers fj Q
46. lows you to define the Start and End parameters for your scanner The other parameters are similar to the Auto section The button adds a new program with the current settings to the list 3 Unfold the list of scanning programs b Click the Show scan program button to open the list of programs A Each line of the scan program consists of one or more linear sweeps where the scan head is Scan Program moved along the linear axis in discrete steps between the From and To positions while the rotation and swing axes are locked From Toa Rot Swing You can achieve good coverage of the part s surface by putting together several sweeps 16x Swing 45 00 Res 0 10 6 x Swing 45 00 Res 0 13 7 39 7 21 0 00 7 39 f21 60 00 7 39 7 21 120 00 7 39 7 21 180 00 4 Edit the program If necessary edit the scan program parameters using the following options Add Line inserts a new line into the program to the end of the program The elements in this line can be edited manually by double clicking Delete selected line from the scan program deletes the selected line in the program Delete scan program removes the whole program from the list Update the selected line with current settings uses the parameters you set in the edit box for the selected line To have more control over the scanning process you can use the Display settings window in the upper right corner of the main window Display Settings If you select the Displ
47. lows you to select the Metric or Imperial system for your measurements Dongle Server Service Address the address of the computer in which the dongle is inserted 54 Old scan data management v Delete old raw scan data DCM files O Created Accessed More than 200 days ago Locale options Units system Metric Dongle Server Service Address 127 _0 _0 _1 Default scan in project Last e Options Options Visual Popup Menu Advanced Options This tab allows you to load the image of your logo to be displayed in the report ia a ae ate For more information please see the section Report Click Apply to view changes Click OK to save the result and close the Customization 3 S h a D e gt window 12 CONVINCE COMPONENTS The main window of Convince Standard comprises the following toolbars and menus Om Convince Crown dem test project 9 Crown Unn2 dem Ox 7 Main menu 5 3D scene 2 Main toolbar 6 Features too bar 3 Annotation 7 Right click menu 4 Visualization toolbar 8 Views 55 1 The Main Menu Click on the Main Menu p gt button in the upper left corner of the main window to open the following options l l File A Project Manager Project Manager Brings you to the Project Manager window view more in the section e Project Manager iii A Load Reference Load Reference Loads a reference model see more in Loa
48. m installer version 1 4 2 0 includes 3Shape Convince Analyzer Installed version 1 4 2 0 2010 1 1 4 2 1 3Shape Dongle Driver Installed version 3 6 3 2010 1 3 6 3 3Shape Dongle Updater Installed version 1 2 5 0 2010 1 1 2 5 0 Installed version 1 0 18 0 3Shape Dongle Service 2010 1 1 0 18 0 61 4 View information on the full installation packages for Convince Standard Select the Install missing components only checkbox to install only those elements that your system is lacking Packages for Convince full installation f Installed version 3 6 3 CN 3Shape Dongle Driver Installed version 1 2 5 0 3Shape Dongle Updater s Installed version 1 0 18 0 3Shape Dongle Service D E S Installed version 8 0 56336 Microsoft Visual C 2005 Redistributable Installed version 4 30 2100 0 P Microsoft XML 4 0 SP3 Redistributable a Installed version 2 0 50727 Microsoft NET 2 0 Redistributable Installed version 1 0 02 3Shape Report Interface Installed Configure Installed version 1 4 2 0 3Shape Convince Analyzer 3Shape Convince Database Install missing components only If you need to configure the 3Shape Convince Database click the Configure button There you can choose between the existing database or create a new one The connection to the database is checked with the 7est Connection button Once completed click the OK button to save the changes and return to the previous page Create ne
49. nner is being connected to your own computer You can also connect it to another computer if only they are on the same network 1 Run the ScanServer program on the computer the scanner is connected to Scan Settings 2 Start Convince Standard on the other computer and choose Main menu gt Scanning Scanner selection gt Scanner Settings to open the Scan settings form Current scanner This computer ip address 127 0 0 1 Add scanner to list 3 In the field next to Add scanner to list you can enter either the ip address or the name of the computer that the scanner is connected to Remove current scanner from list 4 Click the Add button to add it to the list of scanners 3 2 3 SCAN PLANNING In order to make a more customized scan than described in the Quick Scan Guide chapter you need to plan your scan more thoroughly It could improve the speed size and quality of the scan 1 In Convince Standard click the Open scan mode button to open the scan menu e 2 Press the Define scan program tab and then the Show scan program button in order to unfold the scan planning settings in the Scan program window d Scan Planning and Execution dd Scan Planning and Execution pyre meena Define Scan Cylinder Place Reference Model HEIRESS a CE Place Reference Model f Define Scan Program Define Scan Program TEE Set from view gt Linear Position E Auto Custom swing 62 04 Resolution 0 10 Sc
50. ns 2 T Recent projects tab Convince 2011 Recent Projects Browse Sd LA Mame Date Convince Projects gt Test_Project 07 10 2010 17 54 34 Ws Crown Unn3 dcm 03 03 2011 12 70 09 C Project_test 03 03 2011 12 20 10 C test project 10 03 2011 10 53 43 Browse tab 29 New Project Ctrl N New Project Ctrl M Edit N Scanning Rename Open Scan Copy Ctrl C View Statistics Scanning Export Project to package Open Scan View Change log View Statistics Delete View Change log Rename Delete Recent projects right click menu Browse tab right click menu Each page contains four main options This option is available for Admin users only and allows you to change and create measurements see the sections The 3D Measurements and Cross Sections change the scan sequence Click on the Edit mode button to start modifying the project Convince 2011 Recent Projects Search Crown Unn3 dcm test project Date Created 10 03 2011 11 00 16 A e Last Scanned 10 03 2011 11 00 16 se li we Total Scans 2 T 30 6 5 2 SCAN MODE Convince 2011 PE TI Crown Unn3 dcm test project Date Created 10 03 2011 11 00 16 Y O F A Last Scanned 10 03 2011 11 00 16 F Total Scans 2 Click on the black triangle of the Scan Mode button to choose between e Creating a new scan using a 3Shape scanner with the scan sequence defined by the Scanning Ctrl S Admin user Scanning o
51. nt and select Measure Scan gt 2D Point Distance 2 Set the measurement Left click to indicate the second point to get a measurement between the two points You can move the points around by dragging the arrows with the mouse thereby altering the measurement You can also edit the annotation 46 2D Point Distance 1 a 15 604 0 100 15 537 9 5 RADIUS 2D 1 Open the Radius 2D option To measure a 2D radius right click the 2D cross section line of your model and select Measure Scan gt Radius 2D 2 Set the measurement The 2D radius measurement requires at least 3 points A maximum of 10 points is possible To finish adding points before 10 points are placed end the measurement with a double Click The measurement is the radius of the best fit circle through the created points The position of the points can be adjusted manually You can edit the annotation name Radius 1 47 9 6 THICKNESS 2D The 2D thickness is the distance between a placed point and the closest opposite point Right click the 2D cross section line of your model and select Measure Scan gt Thickness 2D 1 The opposite point is automatically found and updated when the main point is moved ee al Th ickness2D 1 10 808 0 200 9 7 WHISKER PLOT 2D The Point difference 2D is the distance between a reference model and a scan at the selected point To measure the 2D poin
52. nue indicating points to form a polygon of a desired shape The last point should merge with the first one to close the polygon The State and the Select visible options are similar to the described in the Brush tool section The Selection toolbar at the bottom contains the following buttons F Select all _ _ selects all the surfaces Invert Selection button inverts the marking on the scan Clear All selections at removes all the selections Undo last action J returns the previous step Cancel A is used to cancel the operation and close the Selection toolbar OK Y confirms the changes made 60 Selection se Ai Mark tool res Shape eae e State a Select visible a a y amp J 14 INSTALLATION The Installation and upgrade of 3Shape Convince Standard is done using the 3Shape Installer The installation process is fairly intuitive and user friendly Follow the steps below to successfully install Convince Standard on your computer 1 Launch the 3Shape Installer 2 Choose the installation language and click Continue Welcome Convince System Installer assists you during installation and upgrade of the software Please follow the instructions Please choose you installation language English Y 3 View the components that are included into the Convince Standard Installer Click Next to continue rm Welcome installer components This Convince Syste
53. o manipulate and edit the models 1 View scenes 2 Round menu 3 Visual options 4 Instruments Note If you need to create projects you should add an account with the administrator rights by marking the corresponding check box See step 2 2 REFERENCE OPERATIONS 2 1 LOAD REFERENCE When you click on the Load Reference button in the Main toolbar the dialog box appears Select the desired model there and click Open When you select a file a preview will appear in the small window in the upper right corner see image below Load reference x Look in J Premium Posteriors 0 reg Name Date modified Type Size e Pb Crown Unn2 dcm Recent Places gt E TO Pp Crown Unn4 dcm uE Pp Crown Unn5 dcm Desking gt Crown Unn12 dcm a Pp Crown Unn13 dcm Pb Crown Unn14 dcm P gt Crown Unn15 dcm V Bring model to center Margaryta D Crown Unn18 dcm Belyaeva gt Crown Unn19 dcm i A P gt Crown Unn20 dcm gt P gt Crown Unn21 dcm Computer P gt Crown Unn28 dcm y File name Crown Unn3 dcm gt Files of type Al supported fomats The supported file formats are STL DCM PTS STL ASCI VRML NMS You can also open a reference file by dragging it onto the main application window 2 2 CREATE A MEASUREMENT a EE I I EE ETS Right click the surface of the model to open the menu and select the necessary measurement The appearance of the right click menu changes depending on the selected menu type Round
54. of points in the scan Statistics Points 5002 Min shows the minimal distance from the evaluated object to the scan E Min 0 1 703 Max shows the maximal distance from the evaluated object to the scan Max 0 1742 Expected 0 0019 Expected statistical expected value of the point differences set Wapferaee 0 0039 Deviation 0 0625 RMS 0 0625 Deviation statistical deviation of the point differences set square root of variance In tolerance 40 8437 Out tolerancel 59 1563 Variance statistical variance of the point differences set RMS Root Mean Square of the point differences sets In tolerance the percentage of points that passed the difference map acceptance criteria green zone Out tolerance the percentage of points falling out of the measures of difference map by statistics 8 3 POINT DIFFERENCE eee ee ee ee ee ee a m e The Point difference is the distance between a scan point and the corresponding mapped surface on a reference model This point can be placed anywhere on your model To measure the point difference you need to select a surface right click on it and select P gro Measure Points gt Point Difference You can view the coordinates of the placed point by clicking the black arrow at the bottom of the annotation Difference 1 0 100 0 098 Y 1 764 Z 1 422 A a The Scan Volume measurement displays the scan volume of the selected part in mm3 or
55. open the Advanced Scan Settings dialog divided into two categories e Scanning contains settings for the scanning process e Post processing triangulation contains settings for triangulation You can select either Default or pre arranged options optimized for Small Dark or White objects You can also create your own Custom settings If you want to add delete presets a Options M click on the Options button and select Save As to create a preset or Delete to remove it pee clout z from the list Select Return to 3Shape settings to reset the values not available for the user ra i White defined presets Custom De Return to 35hape Settings It is possible to Adjust Laser target intensity and Scanning speed that have influence on Scanning i the scanning process You might benefit from setting the Intensity to High and the Rae Scanning speed to Slow if you have a very dark object to scan ppi oe Intensity Law Adjust Iterations 1 High Data handling section allows you to mark the Indexed tracking checkbox to get less noisy raw scan data This however can cause the loss of some very fine details Scanning Scanning speed Data handling Indexed tracking 4 SMP scanner Cluster diameter you can decide how many points should be in each area sphere where Post processing triangulation you reduce your raw data A lower value gives better coverage however a higher value yields less noise R
56. our search IE Documents MI Desktop E Recent Places Computer E Pictures i Music 44 Recently Changed B Searches Ji Public Folders A File name Save as type DXF Drawing Exchange Format 2D dxf z 10 VISUALIZATION AND E LEARNING TOOLS The software is designed to convey the concepts of measurements through learning by doing Several visual settings and effects contribute to the learning experience Most of the options can be activated from the Visualization toolbar while those that are used less frequently are located under the Main menu p gt gt Vjew gt Options 50 P gt 3Shape Convince Crown Unn3 dcm test project 9 Crown Unn2 dcm _ OX 12 Options Full Screen View Scanning Measure gt Annotations On Top Hide Annotations Help Show Annotations 7 Options menu 2 Visualization toolbar 10 1 SHOW LIST OF MEASUREMENTS The Show List of Measurements list of measurements available within the project The measurements appear under the corresponding expandable classifications in the list Visible makes the annotation visible invisible Rebuild refreshes the measurements Delete removes the measurement M The right click menu contains the following options For further information see the section List of Measurements You can change the visibility settings of the annotations
57. ows up down SHIFT Bring up a popup menu Click on the right button AN The Visualization toolbar contains the options for some standard perspectives and standard zoom see the section Convince Components The right click menu automatically adjusts to what is clicked on listing only relevant and legal choices You can navigate within the menu if the menu type System and not Round is selected in a standard way arrow keys to move up down ESC to quit and ENTER to select 58 12 2 RIGHT CLICK MENU EA a a EEEE With the right click on a model you open a popup menu that comprises measurements relevant for the current model The right click menu can be configured in the Main Menu a Measure Points y Cross sections dk Configure Volume measurements P gt gt View gt Options gt Popup Menu see the image below Difference map System menu You can change the appearance of the menu by choosing either System or Round menu type in the he Popup Menu tab For more information on the right click menu customization see the section The Custom Settings Menu Round menu 13 SELECTION TOOLBAR The Selection toolbar contains the Brush Automatic and Mark tools to work on the loaded scan You can select the surface of the scan by painting it Selection he AED The selection tool looks like a black circle and the selected area becomes colored in light blue Brush tool Shape O 6 State Select vi
58. r e Opening a saved scan Open Scan Open Scan Ctrl O In both cases the measurements defined in the project will be evaluated according to this particular scan and the results will be placed in the history for this scan See more about setting up a scan sequence in section Creating a Scan Program The scan flow in the Scan Mode contains the following options Place the object into the scanner Try to imitate the shown placement of the reference model if there is one Press Scan Trim your scan if required Align your scans if necessary if you have multiple placements see the chapter Multiple Scan Placements Click Next to go to the next placement if required Finalize your scan Finalize View chapter Scanning for more information on the scanning process 31 6 5 3 STATISTICS To view the history of a project and view measurement statistics click the Statistics button of a Project Manager to open the Statistics page Convince 2011 Recent Projects Search Crown Unn3 dcm test project Date Created 10 03 2011 11 00 16 A Last Scanned 10 03 2011 11 00 16 J a Total Scans 2 T 6 5 4 REPORT OF THE PROJECT aaa 5 The Report button creates an inspection report and saves it automatically on your computer in the pdf file format Convince 2011 Recent Projects Browse Search Crown Unn3 dcm test project Date Created 10 03 2011 11 00 16 Last Scanned 10 03 2011 11
59. re information see the section Difference Map Menu Show bands Autoscale Show difference at cursor Enable Wisker Plot ROI difference only Show Whisker Plot Options Show Statistics The Statistics window appears in the main window and shows statistics for the current difference map for more information see the section Available Statistical Information 8 2 1 DIFFERENCE MAP MENU A A A A A A A A A A A A RY To open specific settings for the difference map click the Options button at the top of the Color scale window and select the desired option from the appeared menu coor sens Show bands e Show bands Makes it easier to see slices on difference map with the same deviations es e Autoscale Automatically adjusts the scale of the difference map Show difference at cursor Enable Wisker Plot ROI difference only Show Whisker Plot Options Y Show Statistics Show difference at cursor Shows the difference at that specific point when you hover your mouse on the model Enable Whisker Plot Enables the whisker plot see the section Whisker Plot ROI difference only Creates difference map for the selected area only Once chosen this option opens the Selection toolbar Select the desired area and click the OK Y button 38 You get the difference map of the selected area only Show Whisker Plot Options Changes the settings of the whisker plot See the section Whisker Plot Show Statistics Ena
60. rements History Graph I S Angle 1 Angle 2 2 Difference 1 Difference 1 Difference 2 Difference 3 Difference 4 G Difference 5 E T Difference 7 E Z a 03 16 0 266 0 216 0 166 0 116 0 066 0 016 0 034 0 084 0 13 e 7 o Measured value mm v ID Project Version Created Evaluation Passed Fail Missed User Report Default Y 1 a 10 03 2011 10 59 5 Passed 0 0 0 qcadmin y 2 Y 2 10 03 2011 11 00 1 Passed 0 0 0 gcadmin gt Y 3 Y 3 10 03 2011 16 23 07 Fail 0 0 1 gcadmin Y 4 Y 4 10 03 2011 16 23 51Fail 0 0 1 gcadmin Y 5 Y 5 10 03 2011 16 34 13 Fail 1 0 1 gcadmin Y 6 Y 6 10 03 2011 16 39 01 Fail 1 0 1 gcadmin Y 7 8 11 03 2011 10 02 21Fail 0 8 0 qcadmin Y a Y a 34 The History Graph in the right upper corner of the screen presents the measurements of the selected project through the graph tables Select the desired measurement from the Measurements list to the left and view their history graphs rc Measurements History Graph ld y 39 5 Angle 2 Difference 1 34 5 Qo R gt Difference 1 Difference 2 Difference 3 Difference 4 Difference 5 Difference 6 Difference 7 Measured value mm J Scan ID j V Show Labels You can switch between the Curve and Histogram modes and use the Zoom chart tool if needed The Statistics page allows you to view the history of the scans created for a project and view statistics related to the measurements The green line on the History Graph show
61. s the ideally accurate coincidence section of the scan and the reference model The top bottom for curve and left right for histogram red lines tolerance boundaries show the upper and the lower acceptable limits for the difference between the scan and reference model The table located below the graph displays detailed information about the scans in the project To select the desired scans place a green tick Y In the first column of the table This will result in changes on the history graph The preview image in the upper left corner illustrates the selected scan ID Project Version Created Evaluation Passed Fail Missed User Report Default Y 1 Ed 1 10 03 2011 10 59 5 Passed o 0 o qcadmin gi gi Eo a Man nina ES e aes 5 r jal Aan There are the following sections in the table oo ltem i eseription o D hows the consecutive number of the project s scan This ID is used in the X axis of the graph Shows the ID of the project version The project version is a set of measurements for the project s tasks with the specific details As soon as some changes take place there appears a new project version Created Shows the creation date Shows the result of the measurement which can be either Passed or Fail Passed evaluation is given if all the measurements evaluation related to a given scan are located within the tolerance boundaries Otherwise it is Fail Missed Shows the number of measurements that could not be evaluated e g due
62. s through the selected surface The other settings are similar to the already described in the 2D measurements plane section 9 2 EDITING PLANES To enter the editing mode click on the Plane Control button located in one of the corners of the 2D measurement plane See image on the left or if you are working in a 2D mode see the following image you can access the editing mode from thee Plane Control Offset mm 4 0 00 Retaton 360 00 sutcharecton Swine e q Copy x Delete lla eng in mm adie _ Lol a shape 44 The Plane Control contains the following settings e Offset Translates the plane in a normal direction You can use the scroll bar or click and enter an offset value manually e Rotation Rotates the plane around the main axis You can also rotate the selected cross section by dragging its blue control point turns yellow when active Switch Direction Changes main axis according to reference geometry 2D Mode Transfers view to from 2D Reset Resets all changes Copy Allows to copy a 2D measurement plane with all its measurements Delete Deletes the 2D measurement plane and all measurements attached onto another surface of the model To copy a 2D measurement plane with all its measurements 1 Click the Copy button 2 Exit the 2D mode by clicking or button 3 Right click on a surface on the model and select Configure gt Paste A
63. s toolbar To make the measurement invisible rebuild or delete it right click on it and choose the necessary option from menu 4 Coordinate Systems Coordinate System Alignment View 1 Coordinate Visible 2 Delete X Rebuild The range of values around zero are colored green by default gradually changing to red for positive deviations and blue for negative deviations To activate the Difference map select ONE of the following options Select the Difference map button on the Features toolbar Click the Difference map button on the right click menu 37 a ix Scanning Measure Difference map Help Generate Report You can view the results in the main window If you point the cursor at the element you can see the distance between the reference and scan models in that particular spot Color scale x Options 0 121 Statistics x Points 5007 1 6285 0 100 0 4683 Expected 0 4374 Variance 0 1702 Deviation 0 4125 0 075 RMS 0 6012 In tolerances 4 4182 Gut Eolerance 61 95 5818 0 050 You can adjust the visual appearance of colors on the element Click on one of the threshold values that are underlined in the Color Scale see the image above and enter the desired numerical value You can also change the numerical value in the Main Menu P gt gt View gt Options gt Diff map max value Diff map min value The Color scale window has its own drop down menu for mo
64. scan points to the reference elements and evaluation of the measurements 3 2 5 MULTIPLE SCAN PLACEMENT If you have an object where you wish to get a full coverage scan you can do this using several placements Creating multiple placements gives the possibility to physically move the object and make a new scan planning and execution for the new placement This new scan can be merged together with the first scan hence creating a final stl containing both sides of the object Note It is always best to use as few placements as possible The optimal solution is to suffice with one placement It gives more accurate results and is also faster Try to find a single placement that covers all areas of interest on the part however if you need multiple placements the Scan Planning and Execution window lets you step through the individual ones and define partial scan programs for each placement After that there appears some new buttons that allow you to go to the previous placement or delete the current placement gt A Next It is possible to copy the scan program parameters of the previous placement to the recently created one by clicking the button For all new placements you should follow the same procedure from planning the scan see the section Scan Planning to executing it see the section Scan Execution 3 2 6 ADVANCED SETTINGS If you wish to change the Scan settings press the button in the Execute Scan tab to
65. sible 746 J There are several adjustments you can make while using the Brush tool Shape select the shape of the brush and set its diameter in the provided field State choose whether to add Ja or remove from the selected area Select visible a setting to select only the visible surfaces otherwise the invisible are selected as well A A A A A A A A A AR A A A A A A Se a ol The software automatically marks the indicated with the cursor surface based on the set selections y 1 1 1 1 E Shape The automatic tool can be set to select either the indicated plane LJ ora j curved surface m State The option to add da to or remove from the selected area Alternatively you can click the star button to select a single surface deleting the other selections Selection Automatic tool Shape gt State Sensitivity Sensitivity with the sliding bar you can regulate the sensitivity of the automatic selection tool DOI The surface area can also be marked with the Mark tool Shape square circle or polygon marking method can be chosen kewl I With the square option indicate a corner draw the square over the area to mark and release the left mouse button With the circle option indicate the circle center extend the circle to the desired diameter and release the left mouse button dio With the polygon option indicate the first point to start a polygon then conti
66. t difference right click the 2D cross section line of your mode and select Measure Scan gt Point Difference 2D 48 Color scale Whisker plot 2D 1 0 100 X Y Nominal 1 994 5 466 Actual 1 987 5 435 Difference 0 007 0 031 1 Model with the whisker plot measurement 2 Color scale window 3 Whisker plot annotation 1 A model with the whisker plot measurement An exaggerated vector is projected out in the normal direction for each point in the slice Its color indicates the deviation 2 Color scale window Click on the Options button in the corner of a Color scale window to open its menu Please see the section The Difference Map Menu for more information j Show bands Y Autoscale 0 10 Y Show difference at cursor 3 Whisker plot annotation The annotation displays the following information e Nominal coordinates of the annotation control point in the X and Y directions e Actual coordinates of the closest point on scan in the X and Y directions e Difference difference between the nominal and actual values in each direction Click the arrow at the bottom of the annotation to view the following e Scale Factor information about the enlargement of vectors for a better visualization e Use threshold an option to turn the threshold on off True False e Threshold limits the length of vectors to the indicated number 9 8 POINT DIFFERENCE 2D On setting the measurement yo
67. u can observe the results in the Annotation If you wish to see the point difference in X and Y coordinates you can click on the black arrow to expand the annotation window Ref the coordinates of the point on a reference model Meas the coordinates of the point on the scan Delta A the difference between Ref and Meas You can move the annotation hence change the coordinates by clicking and dragging the blue arrows 49 Point Difference 2D 1 0 100 X Y Ref 0 362 4 000 Meas 0 364 4 001 A 0 002 0 001 9 9 COPY 2D SECTION AS DXF FILE To copy and save a 2D section as a DMF file go to the Main menu gt File gt Save scan slice as File Ma Project Manager View d 3 Load Scan Scanning In the appeared Save slice window select the target folder type in the file name and click Save fy Save project gt Measure gt gt Help Export project to package Export project data to CSV Save copy of scan Save scan slice as N Project information Exit a a a a a a a 5 5 5 5 1 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1 1 1 a E Save slice 18 Le Crowns Premium Posteriors gt Search p J ooo re By Organize emm Views PY New Folder a ais Name Date modified Type Size No items match y
68. ver icon on your desktop 4 Place object onto a mounting plate and place it into the scanner B Close the door on the scamner Execute the scan 1 Press the Open scan mode button in the Main toolbar to open the scan planning menu see the image to the left Placement 3 3 2 Click the Scan button to start the scan Then click OK to accept and make a default Scan Planning and Execution scan program Define Scan Cylinder Place Reference Model Define Scan Program Execute Scan 3 When the menu appears once more click the Fina ize button to finish your scan Trim Align Finalize l Load x 4 Click Done to close the menu and be able to measure your scan Advanced Cancel 3 2 2 SETTING UP THE SCANNER To be able to scan in Convince Standard you need a 3Shape Scanner Q640 Q700 Q740 or Q800 Connect the scanner to your computer using the enclosed USB cable and turn the scanner ON using the button at the back Then launch the ScanServer program for example by double clicking the ScanServer icon on your desktop On opening the ScanServer you might be prompted to calibrate the scanner This needs to lwo ScanServer b0850214b be done before scanning Options Help The quality of the scans improves if the scanner is calibrated A good indicator for when a scanner might benefit from being calibrated is to observe the temperature See the image to the right If there is a large difference between scanner
69. w database instance Use existing database Server name DELL Severoon O Server pa ssword 3SQCdb 62 5 Choose the time to restart your computer to finish installing the important updates 35hape Installer Installation complete can t update important files and services while the system is using them Make sure to save your files before restarting ier 6 Click Finish to complete installation If the Show log file checkbox is selected the installation log file will appear on the screen on exiting the installer Installation complete CN 3Shape Dongle Driver 3Shape Dongle Updater 3Shape Dongle Service 3Shape Report Interface E SSlepe Comics Analyser e Show log file Finish h Dongle information Dongle number 24661458 Update number Applications enabled Convince Analyzer Internet update Manual update 63 Launch the 3Shape Dongle Updater and view the information on the inserted dongle under the Dongle information tab Dongle Number Number of Updates and Applications Enabled Dongle update can be done either manually or via the internet by clicking the corresponding buttons For the manual update supply your dongle number to a 3Shape representative and receive a dongle update code that you need to fill in the Manual Update form Manual update Enter update code cence To update the dongle using the Internet click on the nternet update button If no updates are available
70. window view the Fite am sections Scan Planning and Scan Execution oe O l View gt ws Scannin gt 4 Scanner settings Test Scanner Accuracy Allows you to test the accuracy of your scanner See more in Test ae 9 Scanner Accuracy section Measure gt Plan and execute scanning Help Test Scanner Accuracy a Difference Map Creates a Difference map in the current view view the section Difference Map File gt Generate Report Creates an inspection report view the section Report anes gt Scanning Help gt Generate Report Measure E Difference map About Opens the window with information about 3Shape Convince Standard version expiration date etc File Users Guide Opens the user manual ES Scanning Help About Send Bug Report Opens the Bug report form allowing to easily report bugs to 3Shape Users Guide Send Bug Report 56 2 Main toolbar contains up to five main program options Note that the appearance of the Main toolbar depends on the project you are currently working on e g with or without a reference model and the user s rights 3 An Annotation Displays the measurement that has been taken e g Point Difference 4 The Visualization Toolbar Contains the options that help you view the model better or from different perspectives View Each button switches the view between different predefined view directions Front