Home

Adam Equipment CBC SERIES

image

Contents

1. ACCUMULATION FUNCTIONS PRINT FUNCTIONS AG Auto AC mAn AC oFF Accumulate and Print automatically Print automatically print automatically M key has no Print Auto Accumulate and print function when M is pressed Automatically Accumulate and print Print when Print Accumulate but not when M or Print is key is pressed print pressed Print mAn M key has no Print only when function Print key pressed Print continuously Print continuously and Print continuously and accumulate accumulate when M automatically when is pressed M and Print key Cont to PC stable have no function Print key no function Print key no function 9 3 REAL TIME CLOCK SETUP The Real Time Clock RTC is used only for the RS 232 output The Date and Time can be set as required The scale will keep the clock running even when the power is off Setting up the clock e Press and hold the CE key when power is first turned on release the key when the revision is displayed The initial displays show the current date and time set nC 1114 06 16 41 39 e Press the CE key to change the date and time The display will show the current time format H m S e Enter the time using the numeric keys using a 24 hour clock format 3 41PM is 194100 Adam Equipment Company 2007 19 Press the Tare key to accept the time The display will show the current date format Press the Prin
2. The display will then show unloAd to request all weight be removed from the platform Press the Tare key to set the zero point Adam Equipment Company 2007 14 e The displays will then show the calibration weight suggested as a whole number For example Either put this weight on the platform after the stable symbol is on or enter the desired value in whole integer and then press Tare e Place the weight on the platform and press Tare again e At all times the scale should be stable before pressing the Tare key to accept a weight The stability indicator will turn on to show the value is stable e When calibration is done the display will show SPAn PASS e Remove the weight The scale will return to normal weighing e f an error message SPAn FAIL is displayed then repeat the process Suggested Calibration weights for CBC Series CBC 4 CBC 8 CBC 16 CBC 32 CBC 48 CBC 8a CBC 16a CBC 35a CBC 70a CBC 100a 2kg 5lb 4kg 101b 10kg 30lb 20kg 50 Ib 30 kg 100 Ib e After calibration the scale should be checked whether the calibration and linearity is correct If necessary repeat calibration NOTE CBCa scales will have the lb or kg indicator on to show the unit of the weight requested If the scale was in pounds before starting the calibration the weights requested will be in pound values or if the scale was weighing in kilograms then metric weights wi
3. to store the value or press the Zero key to escape from this setting and return to weighing 11 0 ERROR CODES During the initial power on testing or during operation the scale may show an error message The meaning of the error messages is described below If an error message is shown repeat the step that caused the message turning the balance on carry out the calibration or other functions If the error message is still shown contact your dealer for further support ERROR CODE DESCRIPTION POSSIBLE CAUSES Err 1 Time input error Tried to set an illegal time i e 26hours Err 2 Date input error Tried to set an illegal date i e 367 day Err 4 Initial Zero is greater than allowed typically 4 of tne maximum capacity when power is turned on or when the Zero key is pressed Weight is on the pan when turning the scale on Excessive weight on the pan when zeroing the scale Improper calibration of the scale Damaged load cell Damaged Electronics A D count is not correct when turning the scale on Platform is not installed Damaged Load cell Damaged Electronics Adam Eguipment Company 2007 20 12 0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories contact your supplier or Adam Equipment A partial list of such items is as follows e Mains Power cord e Stainless Steel Pan e Replacement Battery e In use cove
4. zero point from which all other weighing and counting is measured This will usually be necessary only when the platform is empty When the zero point is obtained the Weight display will show the indicator for zero e The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to press Zero to re zero the scale if small amounts of weight are still shown when the platform is empty 6 2 TARING e Zero the scale by pressing the Zero key if necessary The indicator above Zero will be ON e Place a container on the platform and its weight will be displayed e Press Tare to tare the scale The weight that was displayed is stored as the tare value which is subtracted from the display leaving zero on the display The indicator above Net will be ON Adam Equipment Company 2007 9 As a product is added only the weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will be displayed When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight of the container plus all products those were removed The indicator above Zero will also be ON because the platform is back to the same condition as it was when the Zero ke
5. 05 kg 0 001 kg 0 002 kg Tare Range 4000 g 8000 g 9 9995 kg 32 kg 48 kg Repeatability 0 1g 0 2g 0 0005 kg 0 001 kg 0 002 kg Std Dev Linearity 0 2g 0 4 g 0 001 kg 0 002 kg 0 004 kg Units of Measure 9 kg CBCa SERIES Model CBC 8a UNITS OF MAXIMUM TARE READABILITY REPEATIBILITY LINEARITY MEASURE CAPACITY RANGE Kilograms 4 0000 kg 4 kg 0 0001 kg 0 0001 kg 0 0002 kg Pounds 8 0000 Ib 8 Ib 0 0002 Ib 0 0002 Ib 0 0004 Ib Model CBC 16a UNITS OF MAXIMUM TARE READABILITY REPEATIBILITY LINEARITY MEASURE CAPACITY RANGE Kilograms 8 0000 kg 8 kg 0 0002 kg 0 0002 kg 0 0004 kg Pounds 16 0000 Ib 9 9995 E lb 0 0005 Ib 0 0005 Ib 0 001 Ib Model CBC 35a UNITS OF MAXIMUM TARE READABILITY REPEATIBILITY LINEARITY MEASURE CAPACITY RANGE Kilograms 16 0000 kg 10 kg 0 0005 kg 0 0005 kg 0 001 kg Pounds 35 000 Ib 35 lb 0 001 Ib 0 001 Ib 0 002 Ib Model CBC 70a UNITS OF MAXIMUM TARE READABILITY REPEATIBILITY LINEARITY MEASURE CAPACITY RANGE Kilograms 32 000 kg 32 kg 0 001 kg 0 001 kg 0 002 kg Pounds 70 000 Ib 70 Ib 0 002 Ib 0 002 Ib 0 004 Ib Model CBC 100a UNITS OF MAXIMUM TARE READABILITY REPEATIBILITY LINEARITY MEASURE CAPACITY RANGE Kilograms 48 000 kg 48 kg 0 002 kg 0 002 kg 0 004 kg Pounds 100 lb 99 Ib 0 005 Ib 0 005 Ib 0 01 Ib Adam Equipment Company 2007 4 2 1 COMMON SPECIFICATIONS Stabilisation Time Operating Temperature Power supply Battery Calibration Display Balance Housing Pan Size Over
6. EEA DAM Adam Eguipment CBC SERIES P N 8680 Revision C3 February 2008 Software rev 3 06 amp above Adam Eguipment Company 2007 Adam Equipment Company 2007 CONTENTS CO INTRODUCTION e tit E 3 210 E EE DER eege ee Eesen 4 2 1 COMMON SPECIFICATIONS sit v 5 2 0 INSTALLATION zeme rond dona n 6 Sil MOGATINGS THE SCALE TEE 6 3 2 INSTALLATION OF CBC SCALES eee eee eee nn 6 LW KEY DESCRIPTIONS hlinu ta aa 7 50 LEE ee EE 8 ost WEIGHT DISPLAY tto Eege 8 52 UNIT EIB DISPLAY EEN 8 53 COUNT DiS OA ft vi 9 50 OPERATION egener ee ee E 9 6 1 ZEROING THE DISPLAY it var 9 DUE NADNES OU 9 6 3 PARTS COUNTING EE 10 6 3 1 Setting LEV CIC st ai 10 6 3 2 Counting more EE 11 6 3 3 Automatic part weight updates Linie ini dresse see 11 Bae MOCK COLIMENG Se sloh PK Re eset a oo cere SA eae o 12 6 3 5 Manually Accumulated Totals n 12 6 3 6 Automatic Accumulated Totals 525085 nes sen niet hnisom 13 CAE PARAMETERS EE 13 80 GALIBRATION E 14 CR DN 232INTERFAGE i r OA se o ol s hk rate oka ot oa 15 9 1 INPUT COMMANDS FORMAT nn 17 A2 IRS 232 SETUP EH 18 S REAL TIME CLOCK SETUP hist ll ao eo 19 9A AUTO SLEEPPUNGTIGNI sia doo stalo rov 20 10 0 BATTERY AND BACKLIGHT OPERATION iscussodaocosusnoumemuanoun as 21 101 BATTERY SOA D O a 21 10 2 BACKLIGHT FOR LOD kmain k o 21 EE ERROR GODES duu o oo ra ea 22 12 0 REPLACEMENT PARTS A
7. ND ACCESSORIES eee 23 13 0 SERVICE INFORMATION et ad o a 23 Adam Eguipment Company 2007 1 Adam Equipment Company 2007 1 0 INTRODUCTION e The CBC series provides accurate fast and versatile counting scales e There are 2 type of scales within the CBC series CBC scales are gram kilogram only scales and the CBCa scales are changeable from pounds to kilograms The scales have the same functions except that CBCa scales have the ability to toggle between the two weighing units e There are 5 models in each type with capacities up to 48 kg 1001b e The scales have stainless steel weighing platforms on an ABS base assembly e All scales are supplied with a RS 232 bi directional interface and real time clock RTC e The scales have sealed keypad with colour coded membrane switches and there are 3 large easy to read liquid crystal type displays LCD The LCD s are supplied with a backlight e The scales include automatic zero tracking audible alarm for pre set counts automatic tare pre set tare an accumulation facility that allows the count to be stored and recalled as an accumulated total Adam Equipment Company 2007 3 2 0 SPECIFICATIONS CBC SERIES Model CBC 4 CBC 8 CBC 16 CBC 32 CBC 48 Maximum 4000 g 8000 g 16kg 32 kg 48 kg Capacity Readability 0 1 g 0 2g 0 00
8. S E ASIA Bond Avenue 26 Commerce Drive 7 Megawatt Road Pty Ltd Milton Keynes Danbury CT Spartan EXT 22 Kempton Park 2 71 Tacoma Circuit MK1 1SW 06810 Johannesburg Canning Vale Perth UK USA Republic of South Africa WA 6155 Australia Tel 44 0 1908 274545 Tel 1 203 790 4774 Tel 27 0 11 974 9745 Tel 61 0 8 6461 6236 Fax 44 0 1908 641339 Fax 1 203 792 3406 Fax 27 0 11 392 2587 Fax 61 0 8 9456 4462 E mail E mail E mail E mail sales adamequipment co uk sales adamequipment com sales adamequipment co za sales adamequipment au com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website Visit us at www adamequipment com Adam Equipment Company 2007
9. all Dimensions wxdxh Net Weight Applications Functions Interface Date Time 2 Seconds typical 10 C 40 C 14 F 104 F 230 VAC 50 60 Hz 120 VAC available Internal rechargeable battery 90 hours operation Automatic External 3 x 6 digits LCD digital displays ABS Plastic Stainless Steel platform 225 x 275mm 8 9 x 10 8 315 x 355 x 110mm 12 4 x 14 x 4 3 4 1kg 9 Ib Counting Scales Parts counting check counting weighing accumulating memory pre set count with alarm RS 232 bi directional interface English German French Spanish selectable text Real Time Clock RTC To print date and time information Dates in year month day day month year or month day year formats Battery backed Adam Eguipment Company 2007 5 3 0 INSTALLATION LOCATING THE SCALE 3 1 d m A RE lt a 2 x The scales should not be placed in a location that will reduce the accuracy Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity such as welding eguipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water A
10. cessary the purchaser must inform its supplier or Adam Equipment Company The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems However any freight involved in sending the faulty units or parts to the service centre should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The statutory right of the purchaser is not affected by this warranty The terms of this warranty is governed by the UK law For complete details on Warranty Information see the terms and conditions of sale available on our web site Adam Equipment Company 2007 24 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standard
11. dam Equipment Company 2007 16 In other languages the format is the same but the text will be in the language selected Description ENGLISH FRENCH GERMAN SPANISH a Gross Wt Pds Brut Brut Gew Pso Brut weig Net weight Net Wi Pds Net Net Gew Pso Net Weight per Unit Wt Pds unit Gew Einh Pso Unid unit counted Number of Pes Pes Stek Piezas items counted Number of No Nb Anzhi Num weighings added to subtotals Total weight Total Total Gesamt Total and count printed Print date Date Date Datum Fecha Printtime Time Heure Zeit Hora 9 1 INPUT COMMANDS FORMAT The scale can be controlled with the following commands The commands must be sent in upper case letters i e T not t Press the Enter key of the PC after each command Tares the scale to display the net weight This is the same as pressing Tare key T lt cr gt lt lf gt Z lt cr gt lt l gt Sets the zero point for all subsequent weighing The display shows zero Prints the results to a PC or printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulation function is not set to automatic In CBC series the Print key will either print the current items being counted or the results of the accumulation memory if M is pressed first P lt cr gt lt lf gt R lt cr gt lt lf gt Recall and Print Same as if first the MR key and then the Pri
12. hen Auto print is switched off MR To recall the accumulated memory Pst To set the upper limit for the number of items counted When this upper limit is exceeded the scale will sound the beeper Print To print the accumulated totals to a PC or printer using the RS 232 interface Smpl Used to input the number of items in a sample U Wt Units Used to enter the weight of a sample manually For CBCa it will also select the weighing unit when the Unit Weight display is at zero Tare Tares the scale Stores the current weight in memory as a tare value subtracts the tare value from the weight and shows the results This is the net weight Entering a value using the keypad will store that as the tare value Zero Sets the zero point for all subsequent weighing to show zero Adam Equipment Company 2007 7 5 0 DISPLAYS The scales have three digital display windows These are Weight Unit Weight and Count Weight Unit Weight g pcs WINDOW WINDOW oy M Net of te A AT A ot Memory Charging For CBCa there are indicators for Ib amp kg 5 1 WEIGHT DISPLAY It has 6 digit display to indicate the weight on the scale Arrows above symbols will indicate the following Low battery iy as above Net Weight Display Net as above Stability indicator Stable or symbol VA as above Zero indicator Zero or symbol 30 as above Note Unit indicator Ib kg for CBCa o
13. ing it To lock the Unit Weight and avoid re sampling press U Wt Units e lf the scale is not stable the calculation will not be completed If the weight is below zero the Count display will show negative count B Entering a known Unit Weight e lf the unit weight is already known then it is possible to enter that value using the keypad e Enter the value of the unit weight in grams using the numeric keys followed by pressing the U Wt Units key The Unit Weight display will show the value as it was entered e The sample is then added to the scale and the weight will be displayed as well as the quantity based on the unit weight 6 3 2 Counting more parts e After the unit weight has been determined or entered it is possible to use the scale for parts counting The scale can be tared to account for the container weight as discussed in the earlier section e After the scale is tared the items to be counted are added and the Count display will show the number of items computed using the total weight and the unit weight e It is possible to increase the accuracy of the unit weight at any time during the counting process by entering the count displayed and then pressing the Smpl key You must be certain that the quantity displayed matches the quantity on the scale before pressing the key The unit weight can be adjusted based upon a larger sample quantity This will give greater accuracy when counting larger sa
14. ll be requested 9 0 RS 232 INTERFACE The CBC Series are supplied with a RS 232 bi directional interface The scale when connected to a printer or computer through the RS 232 interface outputs the weight unit weight and count Adam Equipment Company 2007 15 Specifications RS 232 output of weighing data ASCII code Adjustable Baud rate 600 1200 2400 4800 9600 and 19200 baud 8 data bits No Parity Connector 9 pin D subminiature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground The scale can be set to print text in English French German or Spanish See the RS 232 parameters section for details Data Format Normal Output Date 12 09 2006 Time 14 56 27 lt lf gt lt cr gt Gross Wt 1 234 Kg Net Wt for net weight with tare value stored Unit Wt 123 g Kg and g for metric and Ib for pounds PCS 10 pcs lt lf gt lt cr gt Includes 2 line feeds with carriage return lt lf gt lt cr gt Data Format Memory Recall Print Date 12 09 2006 Time 14 56 27 lt lf gt lt cr gt KKKKKKKKKK lt 1f gt lt cr gt Includes 1 line feed TOTAL lt 1f gt lt cr gt Includes 1 line feed KKKKKKKKKK l1f gt lt cr gt lt lf gt lt cr gt 2 line feeds carriage return Pressing the MR key will not send the totals to the RS 232 when the continuous print is turned on The continuous print will only be for weight and display data that is current A
15. mple sizes 6 3 3 Automatic part weight updates e At the time of computing the unit weight see section 6 3 1A the scale will automatically update the unit weight when a sample less than the sample already on the platform is added A beep will be heard when the value is updated It is wise to check the quantity is correct when the unit weight has been updated Adam Equipment Company 2007 11 automatically This feature is turned off as soon as the number of items added exceeds the count used as a sample 6 3 4 Check counting Check counting is a procedure to cause an alarm to sound when the number of items counted on the scale meets or exceeds a number stored in the memory by using the Pst key The value to be stored is entered from the keyboard Enter the numeric value to be stored using the numeric keys Then press the Pst key to store the value To clear the value from the memory and thereby turn off the check counting feature enter the value 0 and press Pst 6 3 5 Manually Accumulated Totals The values weight and count shown on the display can be added to the values in the memory by pressing the M key The Weight display will show the total weight the Count display will show the total accumulated count and the Unit Weight display shows the number of times the items have been added to the memory for accumulation The values will be displayed for 2 seconds before returning to normal The scale must
16. nly 5 2 UNIT WEIGHT DISPLAY e This display will show the unit weight of a sample This value is either input by the user or computed by the scale The unit of measurement is grams on CBC and pounds on CBCa scales e The arrow indicator will be seen above Sample or a symbol as above when there is insufficient number of samples to accurately determine the count e When the unit weight is not large enough to determine an accurate count the arrow indicator will be seen above U Weight or symbol as above e In both cases the scale continues to operate and the indications are to alert the user for a potential problem Adam Equipment Company 2007 8 e f a preset count has been stored the Preset or E symbol as above will have an arrow above 5 3 COUNT DISPLAY e This display will show the number of items on the scale or the value of the accumulated count See the next section on OPERATION e The arrow indicator will be seen above Memory when a value has been entered into the memory 6 0 OPERATION NOTE CBCa Scales only SETTING THE WEIGHING UNIT Ib or kg The scale will turn on displaying the last weighing unit selected either kilograms or pounds To change the weighing unit press the U Wt Units key when the Unit Weight display shows zero If necessary press the CE key to clear the unit weight before changing 6 1 ZEROING THE DISPLAY e You can press the Zero key at any time to set the
17. nt key is pressed Will display the current accumulated memory and print the total results C lt cr gt lt lf gt Same as pressing MR first and then the CE key to erase the current memory Adam Eguipment Company 2007 17 9 2 RS 232 SETUP The RS 232 interface uses parameters set by the user for language baud rate and date format Press and hold the Print key for 4 seconds to access the parameters Press U Wt Units to scroll through the options and Tare to confirm the change and then advance to the next parameter When a parameter is entered by pressing Tare the displays will guide you through the parameter selected and the options available The parameters and their functions are ___ Displays Options Functions Weight Unit Count Weight Port on On Enable or disable the RS OFF 232 interface 4800 bPS 600 Set baud rate 1200 2400 4800 9600 19200 Print mAn Cont to PC Select printing options for Print Auto continuous printing print k automatically or printing Print mAn manually AC min AG Auto Select the operation of AC mAn accumulating automatically manually or turned off AC OFF CoUntr Y E nGLISH ENGLISH Select Language for FrEnCH printing GErMAn SPANISH Adam Eguipment Company 2007 The scale will perform the following functions depending on the Accumulation and Print settings
18. r e Printer etc 13 0 SERVICE INFORMATION This manual covers the details of operation If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance In order to provide further assistance the supplier will need the following information which should be kept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale CBC Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place C Brief description of the problem Include any recent history of the unit For example Has it been working since it s delivered Has it been in contact with water Damaged from a fire Electrical Storms in the area Dropped on the floor etc Adam Equipment Company 2007 23 WARRANTY INFORMATION Adam Equipment offers Limited Warranty Parts and Labour for the components failed due to defects in materials or workmanship Warranty starts from the date of delivery During the warranty period should any repairs be ne
19. return to zero or a negative number before another sample can be added to the memory More products can then be added and the M key to be pressed again This can continue for up to 99 entries or until the capacity of the Weight display is exceeded To observe the total stored value press the MR key The total will be displayed for 2 seconds To clear the memory first press MR to recall the totals from memory and then press the CE key to clear all values from the memory Adam Equipment Company 2007 12 6 3 6 Automatic Accumulated Totals e The scale can be set to automatically accumulate totals when a weight is placed on the scale This eliminates the need to press the M key to store values into the memory However the M key is still active and can be pressed to store the values immediately In this case the values will not be stored when the scale returns to zero e See the Section 9 0 on RS 232 Interface for details on how to enable Automatic Accumulation 7 0 PARAMETERS The parameters are set to customise the scale to suit the weighing applications You need to enter a secure menu by entering a password when requested e Press Tare once during the initial counting of the display after the power is turned on e The Weigh display will show Pln requesting for the password number e The default password is 0000 but other numbers can be set using the parameter menus Press the 0 key four
20. s following the provisions of the below stated directives Electro Magnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC Adam Equipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment WEEE COMPLIANCE F ay Sealed Lead Acid an e Battery 3 e Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be rec
21. t key to change the date format Available formats are Y m year month day m d Y month day year d m Y day month year Press the Tare key to accept the chosen format and then enter the date in this format Press the Tare key to accept the date An error code will be shown if the time Err 1 or the date Err 2 is not the permissible values For example 34 day of a month is an invalid entry 9 4 AUTO SLEEP FUNCTION This function may be enabled or disabled by the user If enabled when the scale is not used for some time as pre set by the user under this function it automatically switches off To set this parameter e During self checking press Zero and release at once The display shows SLEEP node e Press Print key to scroll through the auto sleep values V Auto sleep mode disabled P Auto sleep after 1 minute o Auto sleep after 5 minutes 10 Auto sleep after 10 minutes e Press U Wt Units to set the value The scale returns to zero Adam Equipment Company 2007 20 10 0 BATTERY AND BACKLIGHT OPERATION 10 1 BATTERY e The scales can be operated from the battery if desired The battery life is approximately 90 hours e When the battery needs charging the arrow above the low battery symbol under the Weight display will turn on The battery should be charged as soon as the arrow is on The scale will still operate for about 10 minutes after which it will a
22. times e Press the Tare key e There are 2 functions that can be cycled through using the U Wt Units key The Weight window will show the parameter number and the Unit Price window will show the word describing the function e The first parameter is H CAL See section 8 0 for details e To enter into Calibration function press the Tare key e To exit a parameter press the Zero key e To select the second parameter press the U Wt Units key Adam Equipment Company 2007 13 SETTING OF PIN Display will show F2 Pin This parameter allows setting of a new password number Press Tare The WEIGHT display will show Pin 1 Enter the new password number The Unit Weight display will show dashes Press Tare The WEIGHT display will change to Pin 2 Enter the password again and press Tare The display will show donE to show the new password has been accepted and will return to the menu Record the new password in a secured place To exit a parameter press the Zero key 8 0 CALIBRATION The CBC scales are calibrated using metric weights and CBCa scales are calibrated using metric or pound weights depending on the unit in use before calibration The scale will display a value of the weight to be used for calibration You can enter a different value if desired For entering Calibration see section 7 0 Parameters When FP GAL is displayed press Tare
23. utomatically switch off to protect the battery e To charge the battery simply plug the scale into the mains and switch the mains power ON The scale does not need to be turned on e The battery should be charged for at least 12 hours for full capacity e Just under the Count display is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is green the battery is fully charged If it is red the battery is nearly discharged and yellow indicates the battery should be charged longer preferably overnight e H the battery has not been used properly or it is used for a number of years it may eventually fail to hold a full charge If the battery life becomes unacceptable then contact your supplier 10 2 BACKLIGHT FOR LCD e The backlight of the LCD can be set to be 1 ON at all the time 2 ON only when a weight is placed on the scale or 3 Turned off e To set the backlight press and hold Pst key for 4 seconds e The weight display will show H where XX is the current setting for the backlight Adam Equipment Company 2007 21 e Press U Wt Units to scroll through the options Ha Sets the backlight to be on at all times EL Au Sets the backlight to operate automatically when a weight is placed on the scale or a key is pressed EL OFF Sets the backlight to be off e Press the Tare key
24. void air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep the scales clean Do not stack material on the scales when they are not in use 3 2 Adam Equipment Company 2007 INSTALLATION OF CBC SCALES e The CBC Series come with a stainless steel platform packed separately Place the platform in the locating holes on the top cover Do not press with excessive force as this could damage the load cell inside e Level the scale by adjusting the four feet The scale should be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet e Turn the power ON using the switch located on the right side of the base e The scale will show the current software revision number in the Weight display window for example V3 06 e Next a self test is performed At the end of the self test it will display 0 in all three displays if the zero condition has been achieved 4 0 KEY DESCRIPTIONS YVOOVOO 9000 OA DWOVWE 660 e Keys Functions 0 9 Numeric entry keys used to manually enter a value for tare weights unit weight and sample size CE Used to clear the unit weight or an erroneous entry M Add the current count to the accumulator Up to 99 values or full capacity of the weight display can be added Also prints the displayed values w
25. y was pressed last 6 3 PARTS COUNTING 6 3 1 Setting Unit Weight In order to do parts counting it is necessary to know the average weight of the items to be counted This can be done by weighing a known number of the items and letting the scale determine the average unit weight or by manually inputting a Known unit weight using the keypad A Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted you will need to place a known quantity of the items on the scale and then to key in the number of items being weighed The scale will then divide the total weight by the number of items and display the average unit weight Press CE anytime to clear the unit weight Zero the scale by pressing the Zero key if necessary If a container is to be used place the container on the scale and tare by pressing Tare as discussed earlier Place a known quantity of items on the scale After the weight display is stable enter the quantity of items using the numeric keys and then press the Smpl key The number of units will be displayed on the Count display and the computed average weight will be shown on the Unit Weight display As more items are added to the scale the weight and the quantity will increase If a quantity which is smaller than the sample is placed on the scale then the scale will automatically enhance the Unit Weight Adam Equipment Company 2007 10 by re calculat
26. ycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2007 ADAM EQUIPMENT is an ISO 9001 2000 certified global organisation with more than 30 years experience in the production and sale of electronic weighing equipment Products are sold through a world wide distributor network supported from our company locations in the UK USA SOUTH AFRICA and AUSTRALIA ADAMS products are predominantly designed for the Laboratory Educational Medical and Industrial Segments The product range is as follows Analytical and Precision Laboratory Balances Counting Scales for Industrial and Warehouse applications Digital Weighing Check weighing Scales High performance Platform Scales with extensive software features including parts counting percent weighing etc Crane scales for heavy duty industrial weighing Digital Electronic Scales for Medical use Retail Scales for Price computing Adam Equipment Co Ltd Adam Equipment Inc Adam Equipment S A Pty Ltd Adam Equipment