Home

User Manual - ADFWeb.com

image

Contents

1. In the field ID Device the ID of the KNX side of the converter is defined iol Channel Number The means of the fields for DMX are herne In the field Channel Number the number of channels of the DMX side is defined up to 512 sag channels glee 192 168 The means of the fields for Ethernet are SUBNET Mask Inthe fields IP ADDRESS insert the IP address that you want to give to the Converter 255 pm Inthe fields SUBNET Mask insert the SubNet Mask In the fields GATEWAY insert the default gateway that you want to use This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net GATEWAY 192 168 Figure 3 Set Communication window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 17 di 24 Industrial Electronic Devices KNX ACCESS By pressing the KNX Access button from the main window for SW67821 Fig 2 the SW67821 KNX Access window appears Fig 4 KNX Set Access The means of the fields are 31 7 255 Normal None E 1 If the field Enable is checked the KNX message is enabled In the field Source Address the O Sou rce Add ress to assig n to the KNX Vf OK x Cancel E Delete Row E Insert Row LT Copy Row oh Paste Row message is defined Inthe field Dest
2. Dip1 Functioning Mode Normal Mode H Boot Mode Figure 1 Connection scheme for HD67821 KNX B2 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 6 di 24 Industrial Electronic Devices CHARACTERISTICS The HD67821 is a DMX KNX Converter It has the following characteristics Up to 512 bytes on DMX side Triple isolation between KNX Power Supply KNX Serial Power Supply Serial Mono directional information between KNX bus and DMX bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 CONFIGURATION You need Compositor SW67821 software on your PC in order to perform the following Define the parameter of KNX line Define the KNX messages that the Converter can accept Define the KNX frames that the Converter sends trough the KNX line Define the map of KNX byte that must be written in the DMX side Update the device ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 7 di 24 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC Be
3. A If Fig 7 appears when you try to do the Update try these points before seeking assistance Ver 1 003 Try to repeat the operations for the updating ee Try with another PC FIRMWARE PROTECTION Try to restart the PC If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven or Vista or 8 make sure that you have the administrator privileges Take attention at Firewall lock Check the LAN settings PROJECT PROTECTION Figure 7 Protection window A In the case of HD67821 you have to use the software SW67821 www adfweb com download filefold SW67821 zip ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 21 di 24 d Industrial Electronic Devices MECHANICAL DIMENSIONS 95 mm 3 74 inch DMX KNX Converter HD67821 KNX B2 MAC 10 64 E2 07 42 22 Es RS485 port Serial Nr C4370 S DETHERNET eecoecsoooPse090 71 mm i 60 mm 2 79 inch 2 36 inch Housing PVC Weight 200g Approx Figure 8 Mechanical dimensions scheme for HD67821 KNX B2 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ig User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 22 di 24 Industrial Electronic Devices ORDERING INFORMATIONS The orde
4. Industrial Electronic Devices User Manual Revision 1 000 English DMX KNX Converter Order Code HD67821 KNX B2 for Website information www adfweb com Product HD67821 for Price information www adfweb com Price HD67821 KNX B2 Benefits and Main Features Very easy to configure Electrical isolation Temperature range 40 C 85 C 40 F 185 F User Manual ADFweb com Srl IT31010 Mareno Treviso User Manual Document code MN67821 ENG DMX KNX Revision 1 000 Pagina 1 di 24 For others KNX products see also the following links Converter KNX to www adfweb com Product HD67801 www adfweb com Product HD67802 www adfweb com Product HD67803 www adfweb com Product HD67804 www adfweb com Product HD67807 www adfweb com Product HD67808 www adfweb com Product HD67809 www adfweb com Product HD67810 www adfweb com Product HD67811 www adfweb com Product HD67812 www adfweb com Product HD67813 www adfweb com Product HD67814 www adfweb com Product HD67815 www adfweb com Product HD67818 www adfweb com Product HD67820 Do you have an your customer protocol www adfweb com Product HD67003 BACnet Master BACnet Slave CAN CANopen EtherNet IP DeviceNet Master DeviceNet Slave 31939 M Bus Master wM Bus Modbus Master Modbus Slave Modbus TCP Master Modbus TCP Slave PROFINET Slave SNMP Do you need to choose a device do you want help www adfweb com Cmd
5. IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 12 di 24 Industrial Electronic Devices J ETHERNET PROGRAMMING PORT The Ethernet ports are used for programming the device The Ethernet connection must be made using Connector2 of HD67821 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC is recommended the use of a cross cable ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 13 di 24 Industrial Electronic Devices USE OF COMPOSITOR SW67821 To configure the Converter use the available software that runs with Windows called SW67821 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67821 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 SW67821 DMX KNX Converter Ope
6. Group the Group address 2 level structure 3 level structure or free address structure or the device address is defined In case of Group address the levels must be separated by in case of Device address the parts of the address must be separated by Inthe field Priority the Priority of the KNX message is defined You can choose between the following o System Highest o Urgent o Normal o Low Lowest Inthe field Format the data format of the KNX message is defined If the field Extended is checked the extended format of the KNX message is used If the field ReTest is checked the KNX message is re sent in case of not correct response If the field OnCMD is checked the KNX request is sent when a serial request is received Inthe field Poll Time the delay in ms between two KNX commands is defined if On Timer is checked Inthe field Position insert the byte of the DMX array where placing the information Inthe field Bit Mode insert the start bit of the first byte of the field Position where start to insert the data read In the field Lenght the dimension of the KNX message is defined In the field Mnemonic the description for the request is defined Figure 4 KNX Access window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revisi
7. State green Blinks slowly 1Hz ence pacte l 9 d OFF Device not powered Blinks quickly Boot state 2 Not used yellow icati Blinks quickly Boot state PURSE Commu earn Blinks when KNX frame is received quK yellow Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 4 Not used yellow ON Ethernet cable connected ON Ethernet cable connected 5 Ethernet Link green OFF Ethernet cable disconnected OFF Ethernet cable disconnected l ON KNX Programmation activated Blinks quickly Boot state 6 KNX Programmation red OFF KNX Programmation not activated Blinks very slowly 0 5Hz update in progress OO Led6 Led5 Red Green KNX Prog Link Ethernet Led1 Green Device state eececccooeeec ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 10 di 24 Industrial Electronic Devices a RS485 For terminate the RS485 line with a 220Q resistor it is necessary to put ON dip 1 like in figure Connector6 Dip Switch B RS485 port Dipi Termination RS485 line T S Shield to Isolated Ground k Open 120 ohm Negative wire A Positive wire The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conduct
8. Switch A at OFF position Turn on the device SW6 82 1 Update Firmware from Etherner UDP At this point the configuration firmware on the device is correctly updated ear SEN Firmware Read Firmware when finish Configuration Read Configuration when finish INIT Waiting Ver 1 003 k Execute update firmware FIRMWARE Waiting PROJECT Waiting Figure 6 Update device windows ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ig User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 20 di 24 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update Note When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67821 device J Note e nmm When you receive the device for the first time you also have to update the Firmware in the HD67821 device Warning
9. helpme INFO www adfweb com Phone 39 0438 30 91 31 ig User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 2 di 24 Industrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INDEX UPDATED DOCUMENTATION age Dear customer we thank you for your attention and we remind you that INDEX 2 you need to check that the following document is UPDATED DOCUMENTATION 2 REVISION LIST 2 a putes WARNING 2 Related to the product you own TRADEMARKS 2 SECURITY ALERT 3 To obtain the most recently updated document note the document code EXAMPLE OF CONNECTION 4 that appears at the top right hand corner of each page of this document CONNECTION SCHEME 5 CHARACTERISTICS 6 With this Document Code go to web page www adfweb com download CONFIGURATION 6 and search for the corresponding code on the page Click on the proper POWER SUPPLY 7 Document Code and download the updates FUNCTION MODES 8 LEDS 9 RS485 10 REVISION LIST KNX 11 ETHERNET 12 Revision Date Author Chapter Description USE OF COMPOSITOR SW67821 13 1 000 25 06 2015 Ff All First Release NEW PROJECT OPEN PROJECT 14 SOFTWARE OPTIONS 15 SET COMMUNICATION 16 KNX ACCESS 17 DMX DEFAULT VALUE 18 UPDATE DEVICE 19 WARNING MECHANICAL DIMENSIONS 21 ORDERING INFORMATIONS 22 ADFweb com reserves the right to change information in this manual about ACCESSORIES 22 our product without warning DISCLAIMER 23 ADFweb com is
10. not responsible for any error this manual may contain OTHER REGULATIONS AND STANDARDS 23 WARRANTIES AND TECHNICAL SUPPORT 24 RETURN POLICY 24 TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 3 di 24 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non
11. al Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software SW6 82 1 Software Options 5W6 821 Software Options Connection Options Enable Internet Connection Check Software Update at Start of Program Check Avadable Wipdate In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67821 check automatically if there are updatings when it is launched ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 16 di 24 Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of the converter By Pressing the Set Communication button from the main window for SW67821 Fig 2 the 2W6 821 window Set Communication appears Fig 3 The window is divided in two sections one for KNX one for DMX and the other for Ethernet aia Type KNX TP The means of the fields for KNX are ID Device 3 3 3 In the field Type the type of KNX is defined fixed to KNX TP
12. his product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 24 di 24 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have an
13. ned Configuration of the Converter Begin Examplei Step 1 gt New Configuration Open Configuration Step 2 gt Set Communication Step 3 Step 4 B DMX Default Value Step 5 3 Update Device www ADFweb com Figure 2 Main window for SW67821 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 14 di 24 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration 5W6 821 Create New Configuration Name of the new Configuration Example A device s configuration can also be imported or exported To clone the configurations of a Programmable DMX KNX Converter in order to m configure another device in the same manner it is necessary to maintain the folder GWOo 82 1 and all its contents Open an Existing Configuration To clone a project in order to obtain a different version of the project it is sufficient List of Avaliable Configurations to duplicate the project folder with another name and open the new folder with the button Open Configuration Example2 Example3 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 15 di 24 Z Industri
14. observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 4 di 24 Industrial Electronic Devices EXAMPLE OF CONNECTION KNX network Power Supply OV W 8 24V AC or 12 35V DC DMX KNX Converter HD67821 KNX B2 MAC 10 64 E2 07 42 22 Serial Nr C4370 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Document code MN67821 ENG DMX KNX Revision 1 000 Pagina 5 di 24 Industrial Electronic Devices CONNECTION SCHEME Dip Switch B Dip1 Termination RS485 line S Shield to Isolated Ground Open 120 ohm B Negative wire A Positive wire Green Link Ethernet Connector2 i Ethernet Port RJ45 Plug Button1 Activation of KNX el Programmation LIC E 2E NE hr J a ICA HE y eS www ADFweb com DMX KNX Converter GA a HD67821 KNX B2 MAC 10 64 E2 07 42 22 RS485 port Serial Nr C4370 S QETHERNET V Positive wire V AC min 8V max 24V V DC min 12V max 35V Dip Switch A
15. on 1 000 Pagina 18 di 24 Industrial Electronic Devices DMX DEFAULT VALUE By pressing the DMX Default Value button from the main window for SW67821 Fig 2 the DMX Default Value window appears Fig 5 In this section it is possible to define the default value for each channel of the DMX array when the converter is turned ON 5W6 821 DMX Default Value Figure 5 DMX Default Value window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 19 di 24 Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary If you don t know the actual IP address of the device you have to use this procedure Turn off the Device SW6 782 1 gt Put Dip1 of Dip Switch A in ON position Update Firmware from Etherner UDP Turn on the device Insert the IP Address of HD67821 Connect the Ethernet cable 188 2 os Insert the IP 192 168 2 205 i l i Check the Connection the device Press the Ping button Device Found must appear XE l Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dipl of Dip
16. or foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG twisted pairs conductor foil shield braid shield ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 11 di 24 Industrial Electronic Devices KNX KNX is the standard that allows the automated and decentralized management of the technologic plans of a big typology of structures commercial buildings factories houses public locals schools and so on KNX can be used in all the applications and functions for the building automations from lighting to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Normal bus powered devices Optional remote powered devices Device power consumption 3 mA 12 mA Power Supply Unit PSU DC 30 V Number of PSU s per physical Max 2 Segment Number of connectable devices Max 256 per physical Segment Number of addressable devices Max 255 per physical Segment Total cable length per physical Max 1000 m Segment Distance between two devices Max 700 m Taken from KNX specifications Device supplying ADFweb com Srl
17. ring part number is formed by a valid combination of the following HD67821 KNX B2 Lo Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67821 KNX DMX KNX Converter Order Code HD67821 KNX B2 DMX KNX Converter ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 35mm Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 23 di 24 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate X collection systems mm his symbol on the product or on its packaging indicates that t
18. vce Consumption W VA Connector1 Power Supply OV Ground V Positive wire Caution Not reverse the polarity power V AC min 8V max 24V V DC min 12V max 35V HD67821 KNX B2 V OV ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Document code MN67821 ENG Industrial Electronic Devices FUNCTION MODES The device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dipi of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dip1 Functioning Mode Normal Mode Boot Mode V OV ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com DMX KNX Revision 1 000 Pagina 8 di 24 Phone 39 0438 30 91 31 User Manual DMX KNX Document code MN67821 ENG Revision 1 000 Pagina 9 di 24 Industrial Electronic Devices LEDS The device has got six LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device
19. y problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31

Download Pdf Manuals

image

Related Search

Related Contents

Mitsubishi Electronics FR-A5AR Power Supply User Manual  AN11305 USB In-System Programming with the LPC11U3X  取扱説明書 ビタCシャワー2 R  Samsung SC9150 Manual de utilizare  DNIOAE-OM(Rev.B 以降) 取扱説明書  Kodak DC280 Digital Camera User Manual  Descargar el manual en Pdf  Plantronics T20  製品カタログ  688 User`s Guide  