1. Figure 2 Select the language you want click save appeared to install the control window Xcenter User Manual Wi ICenter 2 0 1 8 install E x Installing Please wait while XCenter is being installed Please wait while XCenter is being installed The installation will take several minutes SK i IE windows must be close before install ocx ORY Execute the commands MMS Gopyright 2010 2008 AGenter zk conc Figure 3 If open the browser there will be a warning Please close all browser click on the ok i ICenter 2 0 1 8 install x Installing Please wait while Center is being installed Please wait while Center is heinn installed The installation will take several minites i Install OCI X install Register OCX success C Windowsisystem3 Execute the commands E Gopyright 2010 2008 saenter Figure 4 Click install and then click exit after making sure the success of registration When there is a Finish Xcenter User Manual click it to complete installation The default path of the software is C Program Files Xcenter Xcenter Vn n n n 2 4 Uninstall Software There are two ways to uninstall the software at user s end Start Programme Xcenter Uninstall Open Control Panel choose Add Del Programme delete Xcenter from the programme list
2. Server name can be blank username and password are the same as login the device s username and password Xcenter User Manual Download Record Files Select a record file in the list click 4 the interface will pop up the menu as follow Download record file URL Time File size Status Save Fath 192 168 55 50 2013 08 19 10 23 34 10_26 36 4 29M downloadi 9 C MyTPCam 2013 06 19 download 192 168 55 50 5000 41410 Download record file Devices IPC351604 192 168 55 50 T Save to C MyIPCam 2013 08 19 Downloadi192 166 55 504141 Tine 2013 08 19 10 23 34 St 10 28 38 S Start Figure 44 Click Start the downloaded file will be storaged under the derectory you selected 3 10 Set Device Parameter Select a window click interface will pop up as follow SE 192 168 55 47 x Audio Settings gt Network Settings Device Name Storage Settings Video Standard PAL ww Alarm Settings Language English M COM Setting Device ID System Version lt WEB Version 2 1 1 1 system Tine Te Vpn Modifying the device language please dose the browser to login Upgrade PTZ Upgrade Restore Reboot hs ery cpr Lr rj Figure 45 The use of the equipment parameter Settings please refer to the document network cameras use Manual 36 Xcenter User Manual 4 SearchCam In the start menu select the program gt XCenter SearchCam an interface w
3. Single Screen Automatic swithing Mian atream Single Screen Automatic swithing Mian stream multi screen Automatic swithing alternate stream Disable hotkey Shortcut keys for screening programs this parameter can only take effect after restarting the software Electronic E map shows at another monitor To display E map on another monitor or not this function requires dual graphics cards Video windows style Display status bar or not Version Display the Version of the current Xcenter software 22 Xcenter User Manual 3 4 2 User set See below picture for the interface of User Set x Common settings User set Record Alarm set Running mode FIP Server Set Map Local User Usemame Privilege admin Admin usr User User User User User User User User User User User User User User C Auto logging in as the user 2 when start the program Set Delete Figure 26 Local User Set the users of this software altogether there are 20 operation users the first one is administrator and others are operators F vote 1 Administrator has the ownership right 2 Administrator can change the operator s permission of function node add or delete operators But it can t change the user name and password of operators Operators can only change user name and password of its own 3 If Auto log in system as user 2 is checked system starts with operator 2 logged in 3
4. Select Alarm Sound File Users can select local sound file but the file must be in wav format When alarm occurs the surveillance center will make a correlative sound A ATTENTION Only after setting the corresponding alarm type alarm message can be displayed when the alarm event occurs 3 4 6 Running Mode See below picture for the interface of Running Mode 26 Xcenter User Manual x Common settings User set Record Alarm set Running mode FTP Server Set Map Running mode select O Passive mode Parameters of passive connection mode Sever port Verify Device User Device UserName admin Device User Password Figure 30 Active Connection Mode The surveillance central actively searches for or manually adds DVS network information Passive Connection Mode DVS actively register network information into surveillance central The usage of the two modes Active Connection Mode applies to most network Passive Connection Mode applies to wireless network or single small surveillance network For example DVS transmits data via CDMA and GPRS When users adopts active mode to connect mobile IP the GPRS CDMA gateway refuses or restricts outside visiting so Passive Connection Mode must be adopted at this time to transmit network information and data to surveillance center When surveillance center adopts Passive Connection Mode please set its service port to d
5. amp English editions of Windows2000 Windows2003 WindowsXP Win7 Windows Vista etc Recommended configuration of hardware environment CPU Pentium 2 6Mhz System Memory 512MB Graphics Card Nvidia Geforce FX5200 or ATI RADEON 7000 9000 series 128M Display Card Memory Graphics Card needs to be hardware scaling supportive Sound Card necessary for audio surveillance and talkback Hard Disk minimum 40G capacity required for image recording ey Software Environment DirectX8 0 version or above TCP IP Definition supported Adaptive resolution equal or greater than 1024 768 system Requirement The PC installed with this software requires a graphics card that supports the color change and zoom of image now the graphics card that has been tested are Nvidia Tnt Tnt2 Geforce Mx200 400 420 440 Fx5200 5600 series ATI Radeon 7000 7200 7500 8500 9000 9200 9500 9600 series MatroxG450 550 and INTEL845G 865G series Please note that the graphics card driver must be hardware scaling supportive Xcenter User Manual 2 3 Software Installation Find the setup file of digital surveillance central management software named Xcenter exe and double click it a window appears as follow Center 27 0 1 6 install Figure 1 Follow the instruction click Next or OK icon until the following window Installing Please wait while XCenter is being installed ROpyright wima 20le AGenter
6. 4 3 Record See below picture for the interface of Record 23 Xcenter User Manual x Common settings Userset Record Alarm set Running mode FIP Server Set Map Record path Record file packing time File directory 10 Minute c MylPCam E Overwrite operation ul Overwrite old files when disk is full obligate space GB Prerecord Prerecord 10 s 1 60 Timer Record Set Timer Record Capture image save path Harddisk XDPicture Date NVS IP PonhNVS Name Channel Figure 2 Add Add User Specified Directory to Directory List Delete Delete User Specified Directory from the Directory list if there are record files under the directory it can not be deleted V It will take effect after being checked Only one user specified directory under one disk partition can be checked Snapped image save to images storage path User specified directory XDPictre Date NVS IP Port NVS Name Channel Record files packing interval Set the packing interval of files in minutes Overwrite operation Enable or disable old file auto deletion function The clear function will be started to delete the files in home directory when the remain space less than the obligate space plus 6G First delete the files of the earliest date if the space is less than obligate space 2 plus 6G then delete the files of the earliest date but one then go on like t
7. ff XCenter 2 0 1 3 Uninstall a _ o x Uninstall XCenter Remove Center From your computer Center wil be uninstalled from the Following folder Click Uninstall bo start the uninstallation Uninstaling From C Program Flest Centeri Center 2 0 1 84 sopynight 2ULG 2018 seente _ a Figure 5 3 Operation of Xcenter 3 1 Software Configuration Change the software s language to Chinese Russian Italy French Polish Click start gt program gt Xcenter gt language Run Language exe will pop up the configuration window as Figure 3 choose one language you want and click Save then close the window 10 Xcenter User Manual Lanquage Please select language Figure 6 Having finished software installation some DVSs may not be able to display normally sometimes for the differences between graphics cards then you should set the following parameters of display buffer auto detection used display card memory system memory and video width The software supports Chinese English run Simplified Chinese or English edition 3 2 Login to start the program the initial user name is admin and password is blank system detects that the password of the administrator admin is blank as the program starts the main interface appears See Picture 6 The password can be changed via this route Local Setting gt Common Setting gt Local User Administration If a password has
8. of cameras and sensors on the corresponded DVS and the name of the DVS After established the E map when there is an alarm the E map will pop up automatically check the Display E map when alarm occurs box in Local Settings flashing of corresponding cameras or sensors indicates an alarm if cameras and sensors are marked out in the E map 3 5 Display Map Click Display map button the map interface will pop up as follow 30 Xcenter User Manual ElectronicMap 2 2m7 8 xX yj DYS Electronic Map v 3 T iM 5 ENN SoS Fy x a EMap20061208163021 H ae Ll RR Eyn PA i j 3 v i i RA current map EMap20061208163021 sensor 0 capture 0 submap 0 Figure 35 The E map can demonstrate accurate position of each camera and sensor it will pop up automatically when there is an alarm If there are cameras or sensors marked on the E map then the flashing of the corresponding cameras or sensors indicates that an alarm occurs at the specific location 3 6 Log Inquiry Click Log button the log inquiry interface will pop up as follow Review log Search condition 2013 08 19 To 2013 08 19 Type Operation Log v Date Time User Content 2013 08 19 10 44 00 admin admin Login 2013 08 19 11 02 03 admin Local Settings Set Other Parameters 2013 08 19 11 32 13 admin Local Settings Set User Figure 36 Xcenter User Manual Choose time range of inquiry at first then choose the type
9. planning person Support and maintenance person Administrator User Notes NVS mentioned in this manual refers to front end device network camera or network video server Device encoder front end device mentioned in this manual refers to front end encoder device network camera or network video server Click Press the left mouse button once Double click Press the left mouse button twice Window name menu name and datasheet DVS Digital Video Server NVS Network Video Server IPC IPCamera Network Camera Modify record Xcenter User Manual Recording the corresponding update the latest document includes all of the content in previous editions According to the write standards 2013 8 12 V2 0 1 8 of our company typesetting the document again Xcenter User Manual Table of Contents DO ect tre tac cnr ceric E E E cn essed assented E E EA A E E E E 6 Er Oe OVE Wena a E E E a 6 1 2 Main Functions of the Software eeeeeeeeeeseeeensesrcerssessrrersesrrtrrsssscerrssrcressssereressretrsesssteresseceeressseeeeseseeeee 6 DZ MSA SOT NS cates cried seas tosses E E E AN T E E A EE E A E E A 7 BM COINS BOT AUG eaea hata sesesandiaibseesapitabuenitaauooiesdasiuusabacummauteanieedeatausctensoninuben tends 7 2 2 Software Running EnvirOnMenl ccccccccccccccecceceeseeseseseseeseeeeeeeseeseessessessecssaaaaaeaaeaaeeeeeseeeeeeeeeeeeeeeeeeees 7 29 POULWAte MIS All AU OM A E E
10. the preset scene can be recalled 2 Recall by track mode Choose the serial No of track press OK Xcenter User Manual Set Track Mode 1 Choose the serial No of the track press Add button See the following picture 2 x Preset position No 5 Figure 18 Add the preset position of the track set stay duration of the preset position 1 120000s Then press OK 2 Choose the serial No and preset position of the track press Add button See the following picture Add Preset Position x Preset position No 1 Name one Stay time 1 s one n Figure 19 Fill in preset point or choose its name set stay duration 1 120000s Then press OK 3 Choose the serial No and preset position of the track press Delete button to delete the preset position F note 1 lf the device of PTZ control is high speed megapixel dome the operation of preset and recall point can be done in dome control 17 Xcenter User Manual 2 The function of dome control is the same as IE interface s you can read the corresponding instruction book to get more details 3 2 9 Image Display Control E ESS SS LL Page Page 1 4 9 16 2536 Downe U pe rl windowse disp Figure 20 Page Up and Page Down is for the scrolling display of current page invalid for 36 Image Mode 3 2 10 Function Buttons Lock Contig Add IPC Playback Map Log ClrA
11. 0 IPC351604 2013 08 19 16 06 56 No 1Motion Alarm 192 168 55 50 5000 IPC351604 2013 08 19 16 07 01 No 1motion alarm disapp 192 168 55 50 5000 IPC351604 2013 08 19 16 07 07 No 1Motion Alarm 192 168 55 50 5000 IPC351604 2013 08 19 16 07 27 No 1motion alarm disapp 192 168 55 50 5000 IPC351604 2013 08 19 16 07 30 No 1Motion Alarm 192 168 55 50 5000 IPC351604 2013 08 19 16 07 32 No 1motion alarm disapp j Figure 38 Xcenter User Manual A ATTENTION Only after Xcenter System log in DVS can all different kinds of warning information be sent to the control center of Xcenter Emergency Control DVS output control switch takes effect after this option is checked Start Stop front peripheral connected to DVS through Output Control 1 or Output Control 2 to achieve the objective of emergency control Such as Light Entrance Guard Video can be previewed real time and emergency control can be implemented by double click certain row of the alarm information list Delete One Delete the warning information selected Clear All Delete all information in the list 3 8 Lock Click Lock icon Hiss system will be locked up you will be asked to input users name and password you can not do any operation until the user s name and password are correctly entered Username Unlock Figure 39 3 9 Record Searching Play back Click Searching Playback button IMEMEW4 the searching pla
12. EE E 8 2A T e SONAE a EE TEAR ATE N 10 3 ODETAUOM Of ACCOM oaeee e EE EEEE E E E A 10 Sl Software OM il AON ss ccosnpaciatastenasstaatauats vwbssunactansmucdosailinnsh inaa ireira sind cinnatnanethonsauchotaoudianteasiaeias 10 Be MMO are E E T E E EE E av acatoavedetadsamesmenceeiesseivssesadestecadens 11 32l ManiMenaCE anrea EEEE E EAE AE E EEEE 12 3 2 2 Image Display WiNdOW seeeseeeeseesseeesssssssessssssrreressssereresssssreeresssssreresssssreresesssrreeeessseereeess 12 See DVS Gel Aton PUNO oeae weseanaelonesaein eaten cane e aE 13 3 24 WAAC ODAC aS arate csas acess nteteseceunesceatec bs tesntiencarions tentesnabanneteadsesctuesae antnatbssotahesieteasuenseusea stant 13 B20 OULU O OEE E E EE A E E deaacuerstacunbesascst 14 IAO CATO ODETA Oair A E EE E EEEE EAAS 15 Se FONNEN Ol ON eare A anced E 15 3 2 8 Set and recall preset POSITION cece cccccssssssscceccessssssseccsssesssesecceseesssseseeeeseeaees 15 3 2 9 Image Display COntrol 0 0 ccc ccccessseccesssssecceeessseecceessseececessseeceeessseeceeessaeeeeeessseeeeensaes 18 Det FUNCION BUWONO crient e E E E EE EEE ETE 18 33 AdU IPE im EAA EN E E EOE EATE E 18 A Be E E E E E E E 21 Al COMMON SS WINGS esra E EEA E E RE EA 21 e USE O aea A E A A EN 23 A RECO he a E N E E E EE 24 3 4 4 Record Schedule eeeeeseeeeeseesssereessssrersssseresssreesssrresssseressssreessssttesssertssseeeessseeeeesseeeeseseeeesse 25 JAS AIM ELp E AEA E E E AE E 25 346 RO
13. NNI MOGE nirien eree E E EEA 26 sar FIF OO a E E E oat 28 FAO Sa ERA AEEA AET A EE E 28 DWTS e IVA E T ATE T N T TTT 30 O Loe MY a E E E E T taakabeamaainanasieaes 31 3 7 Alarm Information amp Emergency Control seeseessessssssesssssssssssssssssreseesrereereereeeeeseessesesssssssssssssssssss 32 NA a E T E EE T E 33 39 Rec rd searching Pliy Dack essiensa e aaa S 33 310 Set Device VP Al ail Esaeren EEE E E EE 36 Ee E a E EE EE A A EEE 3 2 UA E E E E E EE E E E EAEE EEEE E 38 Appendix Default Parameters of ENCOQETr eeseeseeeeeseeesssreesssrrrerssrrersserrrrsssreesssrreesssrreessereeesssreesssreeessrrrese 39 Xcenter User Manual 1 Overview 1 1 Software Overview Central Management Software is designed to realize integrated surveillance storage management and control of all front end equipments including Digital Video Server Digital Storage Video Server IP Camera etc This management software can manage up to 1728 front end network surveillance devices at the same time performing setup control and remote upgrade functions to any of the equipments It supports 1 4 9 16 25 36 displays in one screen two way intercom electronic map log retrieval alarm controlling long distance retrieval and playback Powerful function friendly interface simple operation all of them provide great advantages for users to realize networking application of large scale and long distance network surveillance 1 2 Main Func
14. Operation log alarm log then click Search button the log of the corresponding time will be displayed in the list 3 Alarm Information amp Emergency Control When DVS has alarm inputting system will determine whether or not to display the alarm message and alarm type according to the alarm settings in Config See below picture for the first type of alarm window Alara x 192 168 55 50 5000 IPC351604 2013 08 19 15 58 22 No 1Motion Alarm 192 168 55 50 5000 IPC351604 2013 08 19 15 58 28 No 1motion alarm disappeal 2013 08 19 15 58 36 No 1Motion Alarm 197 166 55 50 5000 IPC351604 2073 08 19 15 56 39 No 1motion alarm disappeal 1927 166 55 50 5000 IPC351604 2073 08 19 15 59 18 No 1Motion Alarm 197 166 55 50 5000 IPC351604 2073 08 19 15 59 21 No motion alarm disappeal 192 166 55 50 5000 IPCS351604 2073 08 19 15 59 28 No 1Motion Alarm Clear All Figure 37 Delete One Delete the warning information selected Clear All Delete all alarm messages in the list of Alarm message See below picture for the second type of alarm window Alarm Info and Emergency Control IPC351604 CAM1 Internal Output i Internal Output i Talk back L Emergency Ctrl Internal Output Internal Output 2xternal Output Ctrl xternal Output Ctrl z 192 168 55 50 5000 IPC351604 2013 08 19 16 06 54 No 1motion alarm disapp 192 168 55 50 500
15. Record Alarm set Running Mode FTP Server Set Map 3 4 1 Common Settings See below picture for the interface of Common Settings 21 Xcenter User Manual x Others _ Auto login device after program running _ Auto connect image while program running Auto reconnect times L Synchronized the device clock which already logined with PC s Snapshot pop up dialog Single screen Automatic switches Preferred Stream multi screen switch _ Disable hot key If changed must restart this soft _ Electronic map shows at other monitor The computer equipped with dual display cards video window style display status bar Figure 25 Select Preview Mode Real time Priority no buffering Fluency Priority buffering improves fluency Frame Buffer set buffer frame rate Auto login Device after program starts When the program starts whether it logs in the DVS groups automatically or not Auto connecting image after program starts When the program starts whether it connects the image groups automatically or not Auto connection Times Enable or disable auto connection set times of auto connection when images are blocked abruptly There are six options 0 25 50 75 100 unlimited Synchronized the Device clock which already logined with PC s Make the Device clock Synchronized with PC s which already logined Snapshot pop up dialog Enable or disable reminder window pop up when snapping
16. Xcenter User Manual XCenter User s Manual for WindowsXP 2003 Win7 Vista Document edition V2 0 1 8 Edition suits for all IP cameras and digital video servers made in our company Xcenter User Manual Preface Thank You for Using our company s products Xcenter also named Center Management software which is designed to realize integrated surveillance storage management and control of all front end equipments including Digital Video Server IP Camera etc This management software can manage up to 1728 front end network surveillance devices at the same time performing set control and remote upgrade functions to any of the equipments It supports 1 4 9 16 25 36 displays in one screen two way intercom electronic map log retrieval alarm controlling long distance retrieval and playback Powerful functions friendly interface simple operation all of them provide great advantages for users to realize networking application of large scale and long distance network surveillance Xcenter User Manual Statement Contents in this manual may be different from the edition that you are using Should any unsolved problem occur given that the product is used according to this manual please contact our technical support department or your product suppliers The content of this manual may be updated at irregular intervals without prior notice Readship This manual is suitable for engineers as follow System
17. ameras now obtainable probes the location of the electronic map in the nextmake a need for external use only the first system of drafting instruments established the first map and the electronic map in the list click the right mouse button choose a function of add option to add an electronic map and give their name double click on the map name to open or oggles the electronic map set Map Close Map procedure Figure 32 Click button the E map interface will be displayed as follow a mrmi og god a mei eet gl Figure 33 Mark the position of every camera and sensor on the E map then it will be clear at a glance First a planar map should be built with the drawing then right click on the list of E map select add to complete E map adding and name it double click the map name to open or switch E map Xcenter User Manual Having finished adding E map cameras and sensors can be established in it Switch to corresponding window by clicking the camera in the E map Select camera or sensor click caption button a window appears as below x Alarm device parameter M exist devide only type c amera 192 168 55 47 a 01Group 192 168 55 47 IPC351801 a 192 168 55 50 IPC351604 197 166 55 140 IPC11669 7 192 168 55 141 IPC11666 192 168 55 145 IPC351611 IPC351801 channel describe IPC3571801 CAM1 Cancel Figure 34 Set the serial numbers
18. ation of the channels selected in list 1 Up and Down can change the number of the window that is linked with DVS channels Down Decrease the number of DVS channel window This function is disabled when the selected DVS channel is linked to its adjacent channels Up increase the number of DVS channel window This function is disabled when the selected DVS channel is linked to its adjacent channels Delete This function is disabled when the selected DVS channel is connected or logged in Set Pitch on the window to be set double click or click Set button the window setting interface will pop up as follow 19 Xcenter User Manual Window Settings Group ID 01 Window 05 User name admin Device name IPC351611 Device URL 192 168 55 145 Communication port 5000 Protocol TCP Channel 1 Camera description IPC351671 CAM1 Encoder Stream Alternate stream Record Stream Preferred Stream Figure 23 User name The DVS users that are connected Password The password of the connected DVS Device s Name The name of the DVS connected it is a unique identifier in the same domain which is to be the identifying mark when transmitting data Repetition should be avoided while setting it up For different channel window in one DVS server s Name login user s name and password ought to be completely the same Derver URL IP address or domain of the DVS connected Communication P
19. been set for admin user login window will pop up when running Xcenter exe Username admin Password Save Cancel Figure 7 Enter user name and password into the login window click OK the main interface of Xcenter will appear 11 Xcenter User Manual 3 2 1 Main Interface Config Add IPC Playback Log Map Clr Alm Disp Img Ground list Last group Group auto change Next group PT control CELETTE Multi image display Connect to selected and image switch group Disconnect selected group Audio Talkback Capture Figure 8 3 2 2 Image Display Window L Green frame indicates that this window is the curently selected window Talkback lt M A ont T broadcast Recording Channel name and HB Alarm Recording Server name cha E Scheduled Recording E Manual Recording Surveillance P Off Figure 9 Double click display window the selected window will be magnified Double click again to return to normal mode Right click display window a menu appears as follow the modes of menus can be different as the mode of windows vary 12 Xcenter User Manual Full Laren a N Window Assign add or delete devices 1 Screen Full screen display images in full screen w 4 Sereens J Sereens 16 Sereens 25 Screens lt j ceeceeee Image Window 1 4 9 16 25 36 display windows 36 Ser eens Connect Image Connect and Disconnec
20. edule has been set for the channel 3 4 5 Alarm Set See below picture for the interface of Alarm Set 25 Xcenter User Manual Local Setting a a p Common settings User set Record Alarm set Running mode FTP Server Set Map Option P Open map when alarm Alarm Record Audio Alarm Popup alarm window _ Show alarm message without video Connect error Video mation alarm Video losing alarm Sensor alarm F Gps alarm Select alarm sound file Connect errar Video motion Video losing c Program Files lt CenterXCenter V2 0 1 8 dw_datalalarm sensor alarm C Program Files XCenter XCenter V2 0 1 8 dvr_datalalarm Figure 29 Setting what events can trigger the alarm window The events include network interruption video motion alarm video loss front end sensor alarm GPS alarm and so on Open map when alarm Enable or disable E map pop up when alarming Alarm Recording Enable or disable local PC alarm recording and duration of alarm recording Audio Alarm Enable or disable audio alarm and the duration of audio alarm When there is alarm the PC audio card will output alarm sound Popup Alarm Window If show alarm message only in alarm window is chosen video and emergency control function will not be displayed in the window
21. etermine whether to validate DVS user or not Besides the settings of front end DVS that is connected to the center must be in line with the above to ensure successful registration A ATTENTION The software needs to be restarted after changing its connection mode 27 Xcenter User Manual 3 4 7 FTP Server See below picture for the setting interface of FTP server Local Setting ha x Common settings User set Record Alarm set Running mode FIP Server Set Map FIP User Aj _ FTP Parameter User Pwd FTP Port root roat FTP Path ci Start Server Stop Server Figure 31 Users can upload the files obtained by scheduled snapshot recording alarm snapshot and recording to FTP server via starting this FTP server FTP User Set user name and password of FTP server FTP Port Port of FTP server the default port is 21 FTP Path The path of FTP server if the path does not exist the device will create a directory automatically Start Server Start the server function of FTP Stop Server Close the server function of FTP Save Settings Save the FTP server parameters after alteration 3 4 8 Set map See below picture for the setting interface of Set map 28 Xcenter User Manual Local Setting er x Common settings User set Record Alarm set Running mode FTP Server SetMap tem of surveillance c
22. his if necessary If the record files are taken on the current date then first delete the files of the earliest hour But files of the current hour cannot be deleted if the disk gets full in one hour the device will stop recording and snapping After the one hour session ends system will delete the files of the hour and continue to record and snap Obligate space default and recommended is 1G Start Pre Record Enable or disable alarm pre recording and duration of pre recording 24 Xcenter User Manual 3 4 4 Record Schedule See below picture for the interface of Set Timer Record Local Setting Select channel All Device Channel Channel Camera title Device name Address 4 IPC351801 CAM1 IPC351801 192 168 5547 IP351604 CAM 1 IPC351604 192 168 55 50 IPC11669 CAM1 IPC11669 192 168 55 140 IPC11666 CAM1 IPC11666 192 168 55 141 IPC351611 CAM1 IFPC351611 192 168 55 145 Enable schedule record Everyday Sun Mon Tue Wed T E Figure 28 Record Schedule setting is to set the recording time for every window whether it is necessary to record each hour in every 24 hours To record select R If Same record schedule for all DVS channels is selected then the record schedule of every channel is the same Start record schedule enable or disable record schedule Only when this option is enabled the channel record schedule can be effective Note mcolor means record sch
23. ill pop up as follow x Device Name Device type Channel Num IP Address subnet Mask Data Port IPC351801 HD IPC351604 HD IPC210069 HD IPC11669 HD IPC11666 HD IPC351614 HD IPC189712 HD Total 7 192 166 55 47 192 168 55 50 192 166 55 135 192 168 55 140 192 168 55 141 192 166 55 145 192 168 55 236 255 255 250 0 255 255 255 0 255 255 250 0 255 255 255 0 255 255 255 0 255 255 255 0 255 255 255 0 192 168 55 1 192 168 55 1 192 168 55 1 192 168 55 1 192 168 55 1 192 168 55 1 192 168 55 1 Local IP 192 168 1 71 kd Figure 46 Search click on the search button to search all coding equipment and related information in the local area network LAN Set Select a device information double click or click set an interface will pop up to set up the equipment information as follow 37 Xcenter User Manual lHzirork Parameter Listi Figure 47 Setting equipment information of Lish1 user name and password must be filled correctly Click OK the equipment will be restarted 5 Language In the start menu select the program gt XCenter Language an interface will pop up as follow English Figure 48 Save Select a language of the interface and then click save Xcenter interface will display to select the language after the restart Xcenter User Manual g Note On English operation system platform PC cannot choose Chinese Xcenter Appendix Defau
24. lm Disp Img Figure 21 Image Display Switch this button controls the display of images on the screen it is usually used when the CPU configuration is low and PC decoding cannot meet requirement or on the condition that only recording is needed 3 3 Add IPCamera Right click on the image window and select Windows Assign or click Windows Assign iconitele a window appears as follow 18 Xcenter User Manual Se ee Gen BE Set groups 48 at a J e emn F E iD E 10885 a 74h B44 rea Nea s Be 193 va bets iis ECM OAOIL TT 12 Tes Tit ee is win ara non E n re oil Li 1 i wd le ae Z It Rao ied 1st Mavi wil Zor NEL ET ate NEL i 14 82 Piece 1 IF JD ii J i 4 TH sera aro cag ee ee ee ee eee ee r List 2 Figure 22 Search Click this icon it search out all of the DVSs and corresponding information on the network and display them in list 2 Add Click this icon to add DVS in list 2 to list 1 Select one entry from list 2 click Add or double click it to add it into list 1 in list 2 indicates all channels of the DVS are added indicates only some channels of the DVS are added white color indicates no channel is added Sequencing click at the header of list 2 to sort the entries in ascending or descending order To sort by DVS Name click the DVS Name header 7 74 7 74 The following functions Up Down Delete and Setup are for the oper
25. lt Parameters of Encoder The default network ports of encoders are 80 Web port TCP 5000 Communication port audio video data transmission port talkback data transmission port UDP 5000 Audio video data transmission port Multi cast Multicast original port channel number port Default network parameters Cabled Network IP Address 192 168 55 100 Data Port 5000 Subnet mask 255 255 255 0 Web Port 80 Gateway 192 168 55 1 DHCP Off Wireless Network IP Address 192 168 1 160 Frequency Auto Gateway 192 168 1 1 Mode Auto Subnet mask 255 255 255 0 Default user information Default Administrator Name admin Password admin Default General User s Name user1 Password user Default General User s Name user2 Password user2 Note User name and password are case sensitive END 39
26. n be enabled when alarm is triggered in a linkage alarm setting you can also open or close them manually via the function buttons provided in the main interface see below picture Figure 13 14 Xcenter User Manual 3 2 6 Grouping Operation Device List 01G gt IPC3IS1604 IPC 35160 gt IPC180023 IPC18002 isht amp 026 on the J group Start Group Record Stop Group Record click O1G a Connect Group Image 16008 013D L36 1600 ee ene o IPC216020 IFC21602 logout recording can be 16001 C21E 16001 C2 performed 17003 A10A IR LO6 I7 b 16003 C21E L04 1600 17006 013D L36 17001 16006 D13D L08 1600 p 16003 D13D L08 1600 17006 C21E L36 700i Group Login Group Logout Gonnech Image Right click Ue IPCam351604 Stark Record to operate IPC Stop Record Login Logout Device Settings Figure 14 3 2 7 Front end Control Zoom Focus Figure 15 3 2 8 Set and recall preset position 1 Set preset position ma Select correct channel and press button a window pops up as follow menu pops up see image Disconnect Group Image 15 Xcenter User Manual Figure 16 Choose the preset point and set its name press OK 2 Recall preset position Press i button a window pops up as follow Stop all channels track _ Figure 17 Recall mode 1 Recall by preset point choose preset point number or its name press OK
27. ort Data port of the DVS connected default value is 5000 Protocol Network communication protocol TCP UDP or Multicast Channel It is to show which channel is connected to current window Channel number begins from 1 for four channel DVS the number is from 1 4 Camera Description Description of the camera connected to DVS channels which is displayed in the status bar It can be input by users Encoder Stream Set liveview encoder stream Recoder Stream Set recoder stream 20 Xcenter User Manual A ATTENTION 1 For different windows on one DVS the server name should be different while user s name and password should be the same 2 Above information can not be changed if video has been connected or channel has been logged in 3 4 Local Settings Click on the Config button SUPE the local settings interface will pop up as follow Others d Auto login device after program running C lAuto connect image while program running Auto reconnect times d Synchronized the device clock which already logined with PCS Snapshoat pop up dialog Single screen Automatic switches Preferred Stream multi screen switch Disable hot key If changed must restart this soft L Electronic map shows at other monitor The computer equipped with dual display cards video window style display status bar Figure 24 There are ten functions in this interface which are Config User set
28. t Image Start and Stop Record Tisconnect Imaze Remote Play Capture operational setting of current window Start Record a Stop Record Capture F2 Login Logout the DVS of current window Note for 4 channel and 2 channel DVS log in to one channel nee He eee other channels will be automatically logged in and vice versa agout Figure 10 3 2 3 DVS Operation Button Connect channels Record all Talk back channels Broadcas stop record all channels Disconnect all channels Snape Figure 11 Audio Surveillance and snap are for operations to currently selected window DVS Parameter Talkback is for operations to the corresponding NVS of currently selected window 3 2 4 Talkback Broadcast An window appears as follow after click icon 13 Xcenter User Manual Talkback amp Broadcast E x System include Device Talk back Device Group ID o gt Group hame Talk ack Devicename _ URL Port_ j paana ater Sampling Rate B000 Audio Coder o711A Taaa UL Add Device Add group gt Add all Delete Device Delete all HL bE Figure 12 You can select DVS then perform talkback or select multi DVS to start broadcasting There are three types of Sampling Rate are optional G726 G711A G711U three audio coder are Optional 32000 16000 8000 3 2 5 Output Control Each video server has four relay outputs they ca
29. tions of the Software Manage 1728 channels of audio and video simultaneously 48 groups Central Management Software can manage all front end equipments including DVS IP Camera and so on to realize integrated surveillance storage management and control Electronic map function Image Preview Surveillance alternation Audio volume can be manually adjusted Audio talkback and broadcast t Image recording pre recording manual recording alarm linkage recording and record schedule Retrieval and playback of records according to channel and date PTZ control Support over 40 kinds of decoder protocols Preset Recall Track Recall Supports video loss video motion abnormal network interruption and front end detector triggered alarm Log management Supports system operation records and alarm records query Front end amp back end snapping Passive Connection Mode DVS Active Connection Mode Xcenter User Manual 2 Install Software 2 1 Getting software Put the companion CD in the package of IP camera or DVS into the CD driver find XCenter setup file from central management software catalog copy it to your PC double click it to run installation After the installation completes find Search NVS software via below path Start Menu gt All Programs gt XCenter 2 2 Software Running Environment ey Operation system 32 bit and 64 bit Simplified Chinese
30. yback interface appears as below 33 Xcenter User Manual Figure 40 In this interface you can search record files and images snapped Multi screen can be selected to play at the same time when there are several record files in the Broadcast schedule list the records will be played in order until all files are played r bpileadwdb ao Respectively openthe file slow play pause stop showing a single frame fast forward back single frame into looping screenshots and video shear Figure 41 Video Splitter click video splitter button to start to split video that is playing click it again and save the file then the video can only be played via Open With Config click sal the interface will pop up as follow 34 Xcenter User Manual Parameters Figure 42 Fi Add devicel click A the interface will pop up as follow 192 168 55 47 5000 IPC351801 admin KA rcamcos comin _192 168 55 140 5000 IPC11669 192 168 55 141 50 IPC 11666 192 168 55 145 50 IPC351611 192 168 55 236 5000 sIPC 189712 IPC210069 IPC11669 IPC11666 IPC351844 1PC351611 IPC351611 Figure 43 You can add modify delete server address it is necessary to input Server address and Port