1. Service Partition Zone Output and Separator The status bar is displayed when at least one widget is placed on it 4 Description of keypad with factory settings 4 1 Template available without login Integrap28 zi Je D time 18 INT TSI SATEL 2 date 3 system status see p 9 4 tap to display the terminal tab 5 tap to arm in full mode all partitions to which you have access from the keypad entering a code will be required 6 tap to disarm clear alarm in all partitions to which you have access from the keypad entering a code will be required 7 tap and hold to trigger the fire alarm tap and hold to trigger the medical auxiliary alarm tap and hold to trigger the panic alarm tap to log in The installer defines the partitions which can be armed using the keypad whether alarm can be triggered from the keypad whether the loud panic alarm with a loud alarm signal or the silent one without a loud signal will be triggered 4 2 Template available after login Integra gt a a l 14 time 2 date 3 system status see p 9 4 tap to display the terminal tab 5 tap to display the tab containing i a the partition list presentation widget 6 tap to display the tab containing the trouble list presentation widget SATEL INT TSI 19 7 tap to display the tab containing i a the event list presentation widget tap to
2. available when the Slave option is enabled Press to find the keypad working in MASTER mode by means of which communication with the control panel is to take place before that press Enable on the keypad working in MASTER mode The network settings may only be edited by the installer and administrators Only one keypad working in SLAVE mode can communicate with the control panel by means of the keypad working in MASTER mode Information about keypad The window displays the keypad name its address in the alarm system etc In addition there is a function available that makes it possible to check if the keypad power supply is appropriate Firmware The window displays information on the keypad firmware Screen cleaning The touch screen can be locked for 30 seconds so as to allow cleaning of the keypad When a dialog box appears asking if you want to lock the screen tap l Remote access The window shows the status of remote access function Touch the keypad screen to enable disable the function When the function is enabled you can save the configuration from the TSI BUILDER program to the memory card via the local network i e without having to remove the card from the keypad The function will be disabled automatically after the keypad restart or after one minute without connection with the TSI BUILDER program has elapsed 8 INT TSI SATEL l Remote access Remote configuration Setting the date time
3. display the tab containing the zone list presentation widget tap to arm in full mode all partitions to which you have access from the keypad tap to disarm clear alarm in all partitions to which you have access from the keypad 11 tap and hold to trigger the fire alarm EI tap and hold to trigger the medical auxiliary alarm E tap and hold to trigger the panic alarm tap to log out 4 2 1 Tab containing i a the partition list presentation widget Integra 128 Hi 2014 01 17 13 45 42 TD D sE Partition list 123 v 01 Living Room Oar _ Kitchen Bedroom 1 E 3 al Bedroom 2 On tap to arm in full mode all partitions to which you have access from the keypad 2 tap to arm in without interior mode partition 1 3 tap to arm in without interior and without entry delay mode partition 1 4 tap to disarm clear alarm in all partitions to which you have access from the keypad 5 partition list presentation widget see p 14 20 INT TSI SATEL 4 2 2 Tab containing i a the event list presentation widget Integra 128 Hi 2014 01 20 07 48 14 5814 2013 10 25 10 33 Disarm by user oS b S Living Room John Smith ga e o en tap to display the alarms logged to event log 2 tap to display the events of arming disarming and alarm clearing type 3 tap to display the troubles logged to event log 4 tap to display the events of zone bypassing unbyp
4. the list the partition which is to be controlled Tap the partition name to highlight the partition Tap the gt icon A window with the list of available functions will be displayed Tap the d icon The tab with the partition status presentation widget will be displayed again Next to the icon s presenting the current status of the partition an icon presenting EE Tap the vV icon The partition status will change the next status will be displayed e g 16 INT TSI SATEL Filtering by name Proceed in the same way as for filtering the zones by name p 13 Filtering by status Proceed in the same way as for filtering the zones by status p 13 3 4 16 Event list E Event log 5815 2013 10 25 08 09 Arm by user S Living Room John Smith It presents events downloaded from the control panel and saved to the memory card in the keypad Double tapping an event will display a window with detailed information on the event Only after you log in using the service code will the following information be displayed panic alarms alarms triggered with the DURESS type code Filtering by text Proceed in the same way as for filtering the zones by name p 13 Filtering by type Proceed in the same way as for filtering the zones by status p 13 Additionally events from the specific time interval can be displayed 3 4 17 Alarm Indicates whether there is an alarm The same icon is used as in the System statu
5. EE 11 SE Zones EE 12 SAAS Outputs EE 13 SA ech ele BCE 14 SATO EVENS E 16 SAI Al WEE EE 16 SES TOUD EE 16 SS KC E G WEE 16 34 20 DCT VI CC EE 16 3 4 21 EIERE eet eege 17 EE 17 3423 SOUPS EE 17 3AA 2S DORAL E 17 SS SR RE 17 Description of keypad with factory settings cccccccceccceeeceeeeeeeeeeeeeeseeeseeeseesseeeeeseeees 17 4 1 Template available without Iogm ccc ccccecceeeseeeeeeseeseeeeeeseeeeeeseeseeeseeseeeeeesees 17 4 2 Template available after logm 18 4 2 1 Tab containing i a the partition list presentation widget 19 4 2 2 Tab containing i a the event list presentation widget 20 SOUNA SII ANG EE 20 5 1 Beeps generated when using the terminal cccccecccecceeeeeeceeeeeeseeeeeeaeeeeeeeeeaees 20 5 2 Events signaled DY sounde 21 2 INT TSI SATEL We are pleased that you have chosen a product offered by us We wish you satisfaction with your choice and would like to assure you that we are always ready to provide professional assistance and information on our products SATEL Ltd is a manufacturer of a wide variety of dedicated devices for use in alarm systems Additional information can be found on our website www satel eu or at points of sale offering our products 1 Introduction Integra 128 07 37 15 10 9012 Ke A graphical interface is displayed on the keypad screen to enable the user to operate the alarm system and to control the home automation devices When setting
6. Naren CE int tsi_ u_en 03 15 Keypad INT TSI Brief User Manual Firmware version 1 04 SATEL sp z 0 0 seul Budowlanych 66 80 298 Gdansk POLAND tel 58 320 94 00 e info satel pl www satel eu WARNINGS Please read this manual carefully before use Changes modifications or repairs not authorized by the manufacturer shall void your rights under the warranty Warning This is a Class A product In a domestic environment this product may cause radio frequency interference in which case the user may be required to take adequate measures The installer manual contains information on how to minimize the radio interference SATEL s goal is to continually upgrade the quality of its products which may result in alterations of their technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us http www satel eu The declaration of conformity may be consulted at www satel eu ce The following symbol may be used in this manual note 1 2 3 4 2 CONTENST Jett ee ee EE 2 At water Ee ae a 2 KEE EE 3 3 1 Itten Eden Be TE 4 32 OUS IGON EE 4 3 2 1 Reie lte Ee e ele EE 4 SSC WOOGIE EE 8 SG E e E 8 3 4 1 ar ie Kee e EE 8 3 4 2 B IWEN 8 3 4 3 TCR OMG EE 9 3 4 4 SE CUE TAS 0 EE 9 3 4 5 RE 9 3 4 6 e e EE 9 3 4 7 Ile ere EEN 10 3 4 8 Ee 10 3 4 9 Camer ME 10 Sees PON e EE 10 EE e DEE 11 3A Kee E
7. You can program the control panel clock in the window Setting the date time jetting the date k gtk sl a035 hA hA hA Setting the t on v v v 3 3 Tab bar The tab bar presents by means of icons the tabs available in the given template Tapping an icon results in displaying the tab 3 4 Tab The tab displays elements called widgets which perform a number of different functions Below are descriptions of all types of widgets which may be placed in the tab by the installer 3 4 1 Analog clock It shows the time 3 4 2 Date Time 2013 10 18 09 11 723 SATEL INT TSI 9 The installer determines which information will be presented the date time number of the day in the year the week number in the year He also selects how the information will be displayed e g the order in which the day month and year are displayed 3 4 3 Thermometer It presents the temperature measured by the ATD 100 temperature detector 3 4 4 System status The status of alarm system is presented by means of icons a alarm or alarm memory none of the partitions operated by the keypad is armed exit delay countdown is running in a partition operated by the keypad all the partitions operated by the keypad are armed some of the partitions operated by the keypad are armed entry delay countdown is running in a partition operated by the keypad information on the partition status is not displayed the keypad is co
8. age 3 4 10 Terminal It enables the alarm system to be operated and programmed in the same way as from the LCD keypad with text menu How such a keypad should be used is described in the control panel programming and user manuals these manuals are available in electronic form on the www satel eu website SATEL INT TSI 11 3 4 11 Weather E Gdansk Poland CEET ai 91 p 7 km h E Thu Fri Sat Sun Mon Tue Wed 10T 9T 8T 4T 8T 3T 9T 2T hehe 8T 4T L sche 2015 03 25 09 55 13 OpenWeatherMap It presents weather and weather forecast The data are downloaded from the OpenWeatherMap service openweathermap org The installer sets the widget size which determines for how many days the weather forecast will be presented SATEL is not responsible for the information presented by the Weather widget The widget presents data provided by the OpenWeatherMap service 3 4 12 Trouble list A Trouble list System battery trouble It presents a list of current troubles The installer can configure the control panel so that the troubles are displayed until cleared by the user Tap B to clear the trouble memory 12 INT TSI SATEL All lists of troubles zones outputs partitions or events you can scroll by tapping the or icon or sliding your finger up and down the screen Tapping the bottom right corner of the list will display the next page of the list and tapping the top right corner will take you to the previou
9. assing type 5 tap to display all events 6 event list presentation widget see p 16 5 Sound signaling The installer can disable the sound signaling 5 1 Beeps generated when using the terminal 1 short beep touching a number key 2 short beeps confirmation of command execution signaling of entering the user menu Submenu or function 3 short beeps signaling of starting the arming procedure if no exit delay has been programmed this is equivalent to arming disarming and or alarm clearing turning output off disabling chime signal in the keypad using the key exiting the function and returning to the menu after confirmation of the data entered 4 short beeps and 1 long beep signaling of turning output on SATEL INT TSI 21 enabling chime signal in the keypad using the key ending the function and exiting the user menu after confirmation of the data entered 1 long beep signaling of violated bypassed zones when arming fault of the vibration detector 10 24H VIBRATION type zone was not violated during the vibration detector test run upon starting the arming procedure 2 long beeps invalid code function not available or exiting the function without e confirmation of the data entered e g by using the key 3 long beeps unavailable function 5 2 Events signaled by sounds Only installer selected events are signaled Ala
10. during which the night mode is to be used Screensaver X PSS Screensaver Initiate the screensaver after mm ss e Energy saving backlight mode Digital Clock v 1 04 Oh Photo Frame v 1 04 Initiate the screensaver after if the keypad is idle for a preset time the screensaver will Start If the screensaver starts before your logout you will need to login again Auto logout after if the logged in user does not perform any action on the screen for a preprogrammed period of time he will be automatically logged out Screensavers the following screensavers are available tap to select Energy saving backlight mode the screen backlight will be reduced to about 20 of the value set for the keypad Digital Clock to configure additional parameters of the digital clock tap gt l Photo Frame a slide show Tap to define how quickly the images will change during the slide show The photos to be displayed must be put onto the microSD card by the installer Network settings Q Network settings Static IP DHCP Q Master Slave Mac 00 1B 9C 04 0E 5C Static IP if this option is enabled you must program the keypad network settings tap one of the parameters below and using the onscreen keyboard that will be displayed enter the data IP address keypad IP address SATEL INT TSI 7 Mask mask of the subnetwork in which the keypad is working Gateway IP address of th
11. e indicating button the button icon indicates the status of the device controlled by means of the button The button allows performance of two different functions depending on the current status of the controlled device e g when the air conditioning is off it can be turned on and when it is on it can be turned off e goto button tapping the button will display a subtab The installer can place in the subtab the same elements as in the tab however the subtab is not shown on the tab bar e filter button the button type available in the tab in which the list of events zones outputs or partitions is placed After you tap the button only the elements meeting the installer defined criterion will be displayed in the list The button can respond to a tap or a long press approx 3 seconds If the button is displayed in the template available without login the authorization with the use of a code may be required after tapping the button Only after the authorization the control panel will execute the operation defined by the installer The button can be described The description can be placed on above or under the button The installer can scale the size of single buttons at will 3 4 9 Camera It displays images from the network camera JPEG MJPEG and MPEG 4 Using additional icons you can pause the display of images start the display of images fit the camera image to window restore normal size of the camera im
12. e network device through which the other devices in the local network can communicate with devices in other networks DNS IP address of the DNS server which is to be used by the keypad DHCP if you enable this option the keypad will automatically download the IP address subnet mask gateway and DNS data from the DHCP server MAC the unique hardware address of the keypad Details this button is available if the DHCP option is enabled Tap the button if you want to check the keypad network settings Master when this option is enabled the keypad is working in the MASTER mode it communicates with the control panel directly through the keypad bus The option is enabled by default Enable the button is available if the Master option is enabled Press to make detection of the keypad possible by the keypad working in SLAVE mode A window will be displayed showing the countdown of time remaining for detection of the keypad After the window Is closed detection of the keypad will be impossible again Slave if this option is enabled the keypad is working in SLAVE mode it communicates with the control panel via another keypad which is working in the MASTER mode IP address of the master keypad IP address of the keypad working in MASTER mode by means of which communication with the control panel takes place Tapping a parameter will display a keyboard which can be used to edit the address Find the button
13. e status presentation widget will be displayed again but the list will only include the zones whose name contains the required text Filtering by status 1 Tap the icon A window will be displayed where the T icon is shown at all statuses 2 Tap the Di icon at the statuses which are not to be displayed The Di icon will be replaced by the B icon 3 Tap the V icon The tab with the zone status presentation widget will be displayed again but the list will only include the zones whose status matches the selected criteria The icon indicates that the zones are being filtered by status 3 4 14 Output list gt Outputs list 001 Power 002 Out siren acoust 003 Out siren optic 004 Indoor siren 005 Roll shutter 1 007 Lighting A 4 14 INT TSI SATEL It presents the list of outputs and their status by means of icons 1 The SHUTTER UP and SHUTTER DOWN type of outouts are always programmed as consecutive and in pairs Only the output of SHUTTER UP type is displayed in the list though the status information applies to both outputs when one of the outputs is activated the other one is deactivated Icon Output status d deactivated r activated does not apply to roller shutter outputs SHUTTER UP type output is activated SHUTTER DOWN type output is activated Output control You can control the outputs of MONO switch BI SWITCH REMOTE SWITCH type and the roller shutter outputs 1 Find
14. in the list the output which is to be controlled 2 Tap the output name to highlight the output 3 Tap the gt icon for the roller shutter output double tap the icon if the SHUTTER DOWN type output is to be activated Next to the icon presenting the current output status an Ba Bx icon presenting the next status will be displayed e g 4 Tap the d icon The output status will change Filtering by name Proceed in the same way as for filtering the zones by name p 13 Filtering by status Proceed in the same way as for filtering the zones by status p 13 3 4 15 Partition list sE Partition list Bathroom Bedroom 1 Bedroom 2 Kitchen Living Room SATEL INT TSI 15 It presents the list of partitions and their status by means of icons Icon Partition status disarmed there are no violated Zones exit delay countdown is running remaining time longer than 10 seconds exit delay countdown is running less than 10 seconds remained armed mode full armed mode full bypasses armed mode without interior armed mode without interior and without entry delay temporarily blocked blocked for guard round entry delay countdown is running fire alarm alarm warning alarm fire alarm memory alarm memory verified alarm memory e OOO SP eI fel EI Partition control 1 2 3 Tap the function which is to be run to highlight it Find in
15. nfigured by the installer so that this information is only available after login trouble or trouble memory the icon is not displayed if the partitions operated by the keypad are armed service mode is active If the installer has enabled the GRADE 2 INTEGRA GRADE 3 INTEGRA Plus option information on the alarms is only displayed after login f the icon indicates that there is a trouble in the system some zones are bypassed or that there was an alarm 3 4 5 Text Any text entered by the installer can be displayed in the tab 3 4 6 Clipart One of the cliparts available in the gallery prepared by the manufacturer or the installer himself can be placed in the tab by the installer 10 INT TSI SATEL 3 4 7 Indicator It indicates the status of selected zone no violation violation or output deactivated activated by means of icons Indicator description can be placed above or below the indicator 3 4 8 Button The following types of buttons can be placed in the tab by the installer e single control button tapping the button will cause the keypad or alarm control panel to perform operation defined by the installer e g arming the selected partitions turning on off the device controlled by the control panel etc e double control button two single buttons grouped together the widget can e g control roller shutters one button raising the roller shutters and the other lowering them
16. o which the user has access from the keypad the alarm will be cleared In the window which displays after the login the following icons may be available tap to disarm all partitions tap to disarm the partitions in which entry delay countdown is running tap to change the code tap to change the phone code tap to delete the service note tap to close the window 3 On screen elements 4 128 JE OKE information bar 2 status Icon 3 tab bar 4 tab Ex INT TSI SATEL 3 1 Information bar The information bar will not be displayed if the user interface is so configured by the installer The following data can be displayed on the information bar e type of alarm control panel e text entered by the installer e date e time e messages about the occurrence of certain events Such as arming disarming auto arming delay countdown entry exit delay countdown alarm etc 1 3 2 Status icon S no logged in user no logged in user entry exit delay countdown is running no logged in user there is a message to read user logged in user logged in entry exit delay countdown is running user logged in there is a message to read Tapping the status icon will open a window in which the following items are displayed e information on the control panel type firmware version build date e name of the logged in user or information that no user is logged in e messages received f
17. rms are being signaled throughout the time programmed by the installer 5 short beeps zone violation CHIME Long beep every 3 seconds followed by a series of short beeps for 10 seconds and 1 long beep countdown of exit delay if the time is shorter than 10 seconds only the final sequence of short beeps will be generated A sequence of 7 beeps of diminishing duration repeated every few seconds countdown of auto arming delay 2 short beeps every seconds countdown of entry delay 2 short beeps every 3 seconds signaling a new trouble Continuous beep alarm Long beep every second fire alarm
18. rom the z control panel or generated by the keypad e icons tap to log in tap to log out _ tap to close the window and turn on the screensaver tap to change the code tap to change the phone code tap to display the Settings window Ki tap to close the window 3 2 1 Settings window The window displays a list of functions which allow you to configure some operating parameters of the keypad or get information on the keypad Tap the selected item in the list to run the function SATEL INT TSI 5 1 Volume EX Backlight Screensaver Q Network settings i E about kevpad l Firmware Screen cleaning Volume I Volume BEI Keys 80 EE 100 I Chime 80 GG The keypad volume levels may vary depending on the type of generated sounds Tap an item in the list to highlight it and then use the slider to set the volume Keys the volume level for sounds generated on touching the screen and when using the terminal Signals the volume level when signaling the exit delay entry delay alarm etc Chime the volume level of CHIME signaling zone violation signaling Backlight Ea Backlight E Day mode I Night mode 199 AL an Alina A Yv hA v 6 INT TSI SATEL The screen backlight is adjustable and may be different depending on the time of day Use the slider to set the brightness If the night mode is to be used turn on the appropriate option and then specify the hours
19. s widget p 9 The widget can be described 3 4 18 Trouble Indicates whether there is a trouble The same icon is used as in the System status widget p 9 The widget can be described 3 4 19 Arm Provides information about arming delay countdown etc in the partitions operated by the keypad The same icons are used as in the System status widget p 9 The widget can be described 3 4 20 Service Indicates whether the service mode is entered The same icon is used as in the System status widget p 9 The widget can be described SATEL INT TSI 17 3 4 21 Partition Indicates the status of a single partition The same icons are used as in the Partition list widget p 14 The widget can be described 3 4 22 Zone Indicates the status of a single zone The same icons are used as in the Zone list widget p 12 The widget can be described 3 4 23 Output Indicates the status of a single output deactivated activated The widget can be described 3 4 24 Separator The installer can put separators between individual widgets The separator has the form of a vertical bar 3 5 LED s Trouble Armed Service Alarm When the screensaver is running the status bar can also be displayed It is used to present some pieces of information on the status of alarm system and its components as selected by the installer It may contain the following widgets Alarm Trouble Arm
20. s page 3 4 13 Zone list Zone list Door Window PIRI PIR2 Glassbreak det It presents the list of zones and their status by means of icons Icon Zone status normal violated trouble long violation trouble no violation inhibited isolated tamper alarm alarm tamper alarm memory alarm memory tamper masking Eege EE EC 3 W EN e G masking memory SATEL INT TSI 13 For the widgets presenting a list of zones outputs or partitions the or WEM icon may be available the tapping of which will change the way of sorting the items in the list When the icon is displayed the list is sorted by name When the EEA icon is displayed the list is sorted by number Bypassing unbypassing zones 1 Find in the list the zone which is to be bypassed unbypassed 2 Tap the zone name to highlight the zone 3 Tap the gt icon Next to the icon presenting the current zone status an icon presenting the next status will be displayed e g i Tap the gt icon again if a different status is required e g if the zone status is normal and the zone is to be isolated 4 Tap the v icon The zone will be bypassed unbypassed Filtering by name 1 Tap the screen area where the Enter text message is displayed An on screen keyboard will be displayed 2 Using the keyboard enter the text which is to be contained in the name and then tap the key The tab with the zon
21. up the keypad the installer creates templates that define how the interface should look like and what features it is to make available to the users The appearance of this interface may be varied not only depending on whether the user is logged in or not but also individualized depending on the user This allows the interface to be customized to the needs of each user of the keypad The interface of keypad which has found its way into your hands may look different than shown in this manual A detailed description of the functioning of particular interface items for your keypad should be obtained from the installer You should present your expectations regarding functionality and appearance of the user interface to the installer The interface should be configured for maximum ease of operation of the alarm system or control of the home automation equipment connected to the control panel 2 Authorization login When using the keypad user authorization login by means of a code is required Having entered the code press the gees key SATEL INT TSI 3 By default the following codes are preprogrammed in the control panel service code 12345 object 1 master administrator code 1111 Additionally the operations which the user can perform using the keypad depend on the user authority level When acting under duress use the DURESS type code instead of the regular user code lf during the login there is an alarm in the partitions t