Home

VSR Instrument User Manual

image

Contents

1. A large range of optional accessories are offered with the VSR instrument allowing you to get the right configuration for your demanding application 3 different telescope options are available wide field of view medium field of view and narrow field of view Additionally 2 different configurations of cold subtraction sources are offered to maximize the contrast A bore siding camera is available to help you point the instrument to remote targets 2 Packing and Visual Inspection 2 1 Front View of the VSR This is a view of the front side of the VSR instrument Connections are made on this side of the instrument The power supply block is removable and can be relocated from the instrument Figure 1 Front view of the VSR Description Cold subtraction source Optical module Contains the instrument modulator and detectors External heat sinks Help keep the instrument stable in temperature Power supply Provide power when not operating on airborne platforms Optical module access purge Electronic module Contains all the electronics of the instrument LR Tech Inc VSR Instrument User Manual 2 2 Rear View of the VSR This is a view of the rear of the VSR instrument facing the target it is currently observing Telescope and additional optics are installed on this side of the instrument Figure 2 Rear view of the VSR Description Electronic module Contains most electronics of the instrument Electr
2. Hygroscopic Materials Notice If the beam splitter of your VSR is made from KBr material follow this section attentively This is a popular material used in IR spectroscopy because of its spectral coverage characteristics KBr is hygroscopic and must be manipulated and store with special care It withstands thermal and mechanical shock well but must not be cleaned with aqueous solvent glycerol the lower alcohols or stored in a high level of humidity environment Inside the sealed interferometer module with fresh desiccant the KBR is well protected Desiccant inside the cartridge must be replaced every year or if indicators 1 wire housekeeping humidity sensor or colored dots show internal humidity of 3096 or higher The Interferometer module Gold finish or stainless steel cylinder module most only be opened by authorized and trained personnel Mishandling of hygroscopic material may results in severe damage of the instrument Under the proper conditions KBR beam splitter will maintain its integrity for several year without any problems 5 Instrument Specifications The following specifications are for the standard version of the VSR If you have a custom modified version of the VSR please refer to the specific specifications provided to you 5 1 Instrument Weight Component Weight Kg VSR Instrument 21 Cold Source 1 Wide FOV Telescope 1 Medium FOV Telescope 3 2 Narrow FOV Telescope 7 Tripod With head
3. 16 Transport Case for VSR Instrument 48 _ Transport Case for Tripod 23 5 2 Expected Components Life Time Components life time listed below are estimates Component Shelf at 25 C Operational at 25 C Laser 7 years 5 years Sterling Cooler 4 years 20 000 hours Note Sterling cooler operational life time for a cooler operating at 77 K 5 3 Power Specifications Power Specifications below are for the standard version of the VSR If your version of the VSR has built in calibration sources or accessories consult the specification sheets provided to you or contact LR Tech Specification Value External power supply input voltage 100 240 VAC 4 0A External power supply frequency range 50 to 60Hz Output power rating 240W Output voltage channel 1 24VDC Output current channel 1 10A Max VSR with cold source current 4 0 A 24 VDC Max 3 4 A 24 VDC Typical If you use the VSR without the provided power supply contact LR Tech to get the input power connector pin out and specifications LR Tech Inc VSR Instrument User Manual 12 5 4 Dimensions j 71 2 cm 52 7 cm Figure 12 VSR lateral view 38 4 cm I Figure 11 VSR view from above the instrument LR Tech Inc VSR Instrument User Manual 13 6 Troubleshooting Issue Solution Anneth Embedded
4. 28V to the power connector Full power specifications are available in the specifications section of this document If your instrument has a cold subtraction source attached connect the cold subtraction source cable to the Aux power connector on the front plate of the instrument 3 2 Telescope Installation The VSR instrument has 3 different telescope options U mE Figure 5 TEL 100M Wide FOV Figure 6 TEL 37M Medium Figure 7 TEL 5M Narrow FOV Telescope Telescope FOV Telescope The wide and medium FOV telescopes are installed the same way on the VSR Push the telescope opening completely in the entrance port of the instrument then align and tighten the ring attached to the instrument Make sure it is completely tightened In order to install the narrow telescope push it inside the entrance port of the VSR Hold it at level with the instrument and start rotating it clockwise In order to get the correct optical alignment the telescope needs to be completely screwed in place Make sure you hold the telescope weight at all time until it is completely tightened in order to prevent damage to it 3 3 Cold Source Installation The VSR instrument has 2 different cold subtraction source options Figure 8 SSP 273 Cold subtraction source based ona Figure 9 SSP 77K Cold subtraction source based ona thermo electric cooler stirling cooler LN2 free All cold subtraction source models manufactured by LR T
5. TECH VSR Instrument User Manual LR Tech inc Andre Lanouette Revision 1 Table of Contents d JhtFOdUCtIOuo nai niin n cet eoh Fo EUn EPI Ra FRETI EYE RDER REFERRE EEPRERE seed FERME ERE RERES AARRE RET AERE ERR SERERE SERE IE es 1 2 Packing and Visual InspectiOl 5 eee oio pereo rante evo Deo europea seo ro Sn ze p inia ee S 2 2 1 Front View of the VSR 5 etri tech ciet esI Ie ret eet Po48 HAIR e ALD H ARR niaar aasa ena iaae iiaeiai diaa eiii 2 2 2 Rear View of the VSR iei seiee nete budet esti teri aae eate ste scere e E e Red en aae ere e addere 3 2 3 FrontPlate View of the VSR icsse ineeie arira iaie aien e iodain taati 4 2 4 Transport Case Layout msnnnnnvnvennernannnnnnennennervennnnnnennennnenssnnnrnennenerensnnnnrneanenenennnnnnrneevesenennnennenseseee 5 3s Instrument Operation orta eee eee eoa rr an eo EP e PPP Een eene E SY EE se Y ve reb Ros EOS EESE Se Eai ESEE rH REPE UNE 6 341 Instrument connections Ee eet Nee ihe iater eee aes 6 32 Telescope InstallatiQEi ii certet oce te soe cose tete eie uacua ated cease ae deae euet eaae n n Re 6 3 3 Cold Source Installation rrr er ree ect etre Pre ee entre epe E e Re E eop o YER Ep dcus 7 3 4 Startup SEQUENCE DEI 7 35 si NetWork Conf pArA tO a colon E 8 3 5 1 Changing the network configuration c cccsscceessecsseceesseceesseceeeeecsaeeesaecseseeceeeeesaeesesaeeeenees 8 3 5 2 Reset your network settings to defaults enne 9 4 Inst
6. Web interface does not respond Edgar cannot connect to Anneth Embedded One of the device does not respond Edgar cannot communicate with one of the devices Local capture mode reports that the disk is full Some scans are being skipped in the data Make sure the board is powered on and connected to your network Make sure the Annotator Ready Led is on and not flashing Attempt to do a ping command to the IP address of the board If it responds then attempt power cycling the board If it doesn t respond revert to factory IP and reconfigure the board network settings Make sure Anneth Embedded is in Remote Connect Mode Make sure every devices are Waiting for connections from the Current status page Make sure the corresponding device is connected physically Make sure the correct RS232 port is defined for the given device Make sure the network TCP port defined in Anneth Embedded and Edgar match Make some room on the hard drive by connecting to the network share and deleting some data files Verify that your instrument configuration sets support the specifications of your instrument speed resolution laser frequency Verify the load average from the local capture mode Current Status page If it is above 2 0 make sure you are not connected to the network share during the acquisition of your data The network share can cause heavy loads on your system 7 Document Revisions The table below i
7. aboratory condition you can expect around 30 45 minutes to get the instrument stabilized in temperature 3 5 Network Configuration The Anneth Embedded web interface allows you to easily configure and monitor Anneth Embedded operations from any web browser By default Anneth Embedded runs on TCP port 8585 with SSL enabled In order to access it open the web browser of your choice and type in the following address https HH HHH HHH HHH 8585 Where Hit Hit Hilt HHH corresponds to the IP address of the Annotator Pro board instrument running Anneth Embedded You will then be prompted for a username and a password in order to access the web interface The default username password combination is admin admin Please note that it can take up to 3 minutes after the instrument got powered on before Anneth Embedded web interface can be accessed 3 5 1 Changing the network configuration Anneth Embedded is the main point of access to your instrument Since it is accessed over a network you will most likely want to modify its network settings In order to do this access the System Configuration page Annotator Pro Network Configuration Current Network Configuration Current DNS 2 Address Network Configuration Obtain IP address via DHCP a static IP address Static IP Address Configuration IP Address Figure 10 Anneth Embedded Network Configuration Page The top section of this page displays the settings curren
8. ech for the VSR uses the same mounting mechanism Simply insert the cold source in the cold source port located on top of the instrument Then screw in place the 2 screws that tighten the ring on the base of the cold subtraction source Connect and secure in place the power connector BD9 3 4 Startup Sequence Make sure your instrument is connected properly and that it receives clean power to its power supply Turn on the instrument by pushing the push button switch on the front plate of the electronic box When power is correctly applied to the instrument and it is turned on the green LED On should be lit After a few seconds the blue Ready LED should start flashing rapidly while the electronics of the VSR are powering up Soon after the blue Ready LED should start flashing slower while the software Anneth Embedded is getting ready to receive a connection from Edgar or to acquire data locally Once the instrument is fully powered up and ready the blue Ready LED should become solid As soon as the ready LED is on you can connect to the instrument using the Edgar software or you can start acquiring data locally on it However to get the maximal radiometric accuracy out of your VSR instrument we strongly recommend that you let the temperature of the instrument stabilize before starting to acquire data Depending on the environment where you operate your instrument the temperature stabilization time may vary In l
9. itance effect the high voltage may be present while the instrument is powered off The VSR spectrometer is designed for indoor and outdoor use but it should not be exposed to excessive moisture rain and dust VSR spectrometers are built with durable urethane paint and anodized aluminum It can be cleaned with soft soap in water 4 2 Telescope Care Protect telescope and its optics by using bags and protective covers provided with the instrument Never touch optical components windows mirrors or lens surfaces with bare hands Use dust free gloves for critical manipulation and cleaning Contaminant Cleaning method Dust Dust contaminant can usually be removed using pressurized gas Fingerprints Fingerprints ona coated lens should be cleaned as soon as possible to avoid staining or damaging the optic Dirt particles Should be removed with a dust free blower before attempting to clean the optic with tissue or cotton The following procedure can be used for cleaning coated ZnSe lens and bare aluminum mirror 1 Dirt particles should be removed with a dust free blower before attempting to clean the optic with tissue or cotton 2 Used soft lens tissue or cotton with acetone to remove dirt and finish it with isopropyl alcohol to eliminate streaks or residue 3 Dry off excess of liquid Take note that bare aluminum mirror is soft Make a test of the tissue used to clean on a small area to make sure not to scratch the surface 4 3
10. llustrate the different revisions of this manual Revision 1 2014 11 26 Andr Lanouette LR Tech Inc VSR Instrument User Manual 15
11. onic module air intake Used to keep the instrument electronics cool Bore siding camera Entrance port LR Tech Inc VSR Instrument User Manual 2 3 Front Plate View of the VSR This is a view of the front plate of the VSR instrument located in front of the electronic module Figure 3 Instrument Front Plate LR Tech Inc VSR Instrument User Manual 2 4 Transport Case Layout Careful attention should always be brought when packaging the instrument for shipment over long distances The VSR instrument is composed of various optical systems sensible to shocks which may break the optical alignment of the system You should always use the provided transport case with sufficient packaging to prevent the instrument and its accessories from bouncing in the transport case Figure 4 VSR Transport Case Layout Item Description Power supply Cables MEM _ Narrow angle telescope Medium angle telescope Wide angle telescope 5 Bore siding camera Cold subtraction sources VSR instrument MEM Acquisition laptop Gold reference plate WN EH o 3 Instrument Operation This section provides basic information on how to get your instrument up and running quickly 3 1 Instrument connections The VSR is easy to install You simply need to connect the power supply cable to the Power connector on the front plate of the instrument If you use an external power supply such as an airplane power provide clean 24
12. rument Maintenance usunne se Fe SERT HI TOP aeos spes PN eU eee ES 10 41 General Gare 1 en LE 10 2524 Telescope care com It EE EEE 10 235 Hygroscopic Materials Notice SA ccc secre cesees eect E eee eee 11 5 ew Instrument Specifications 2 5 9 oe ree rro cecceessceeceessscccsesteensecsssccvesessncccsssseceecsseseoeses 12 Sele wee Instrument Weight 2 28 RE seats heteenr a eeecen ces 12 bee Expected Componentsbifelilmer EE 12 Desk OWenrSpeeifi cat ONS RR oon ceri ene 12 SD ImENSIONS 1 JE SE E e eE T Eee eI EE ts 13 GwEIroubleshooting 5 5 a a 1 eere ero eter eeu eoe enun errant nnn corner re EREMO rennen 14 Document Revisions 29 eee ssccsscesdesscccosess csddessccevccnvcccccccvescs PEE EE EE J cesses 15 1 Introduction This manual is intended to be used by instrument operators as a complement to the formation given by trained LR Tech personnel It provides basic information on the operation and maintenance of the LR Tech Versatile Spectro Radiometer VSR The Versatile Spectro Radiometer VSR is a compact high sensitivity Spectro Radiometer which uses Fourier Transform Infrared FT IR technology Its high speed yet robust operation allows it to be used in different scenarios from laboratory usage to airborne and heavy vibrations environments The VSR can provide real time high resolution spectral information on slow and fast occurring phenomenon as well as perform material and target signature analysis
13. tly applied to your instrument In order to obtain a dynamic IP address from your router select the DHCP option Otherwise select the static IP address option and fill in the required field If you press the Save option your settings will be saved but will only be applied after a restart of the instrument If you press the Save and apply option the board will automatically restart and the new network settings will be applied right away Make sure to adjust the address of the web interface in your web browser according to the new settings you entered 3 5 2 Reset your network settings to defaults If you forgot the IP address that was assigned to the instrument most instruments come equipped with a Factory Reset button If you press and hold this button for 10 seconds you will see the Annotator Ready light begin to flash rapidly After a few seconds the board will be restarted and default settings will be applied network configuration and username password The default network configuration are Hostname IP Address Netmask Gateway Username Password ANNOTATORPRO 192 168 0 100 255 255 255 0 192 168 0 1 admin admin 4 Instrument Maintenance 4 1 General Care There are no user serviceable parts inside the Versatile Spectro radiometer The VSR spectrometer should be opened only by trained and authorized personnel DANGER High voltage inside 6 5 kV at start up and 1400 V steady operation Due to capac