1. gt 6 RD 6 TD 6 TD 1 RD 1 RD 1 RD a 1 TD 2 RD 2 RD 2 RD a A TD Straight Through Cabling Schematic Crossover Cabling Schematic Note The Ethernet cables use pins 1 2 3 and 6 of an 8 pin RJ 45 connector The signals of these pins are converted by the automatic MDI X function as shown in the table below korenix Pin MDI X MDI Signals el mm sl w w Connect one side of an Ethernet cable into any switch port and connect the other side to your attached device The LINK LED will light up when the cable is correctly connected Refer to the LED Indicators section for descriptions of each LED indicator Always make sure that the cables between the switches and attached devices e g switch hub or workstation are less than 100m 328 ft apart The wiring cable types are as follows 10Base T 2 pair UTP STP Cat 3 5e 6 cable EIA TIA 568 B 2 100 ohm up to 100m 100Base TX 2 pair UTP STP Cat 5e 6 cable EIA TIA 568 B 2 100 ohm up to 100m 2 6 Connecting Powered Device PD JetNet 4706 4706f is equipped with 4 Port PoE injectors which are in compliance with IEEE 802 3af standards for 15 4w forwarding capability and 30w High power The powering architecture of JetNet 4706 4 706f follows IEEE 802 3af Alternative B mode standards of conductor assignment The following table shows the pin assignment of alternative A and B for the PSE Power Source Equipment Pt PX negate voor TeaPostve voon 2 RK e Negative voo
2. JetNet 4706 4706f Industrial Managed PoE Switch 32 korenix 4 2 8 Factory Default In this section you can reset all the configurations of the switch to its default settings By clicking on Reset the system will reset all configurations to its default settings The system will show you a popup message window after running this command Default settings will be in effect after rebooting the switch eee Reset to Default CJ Basic Setting Switch Setting Mote The command will reset all configurations to the default settings exceptthe IP address E Admin Password 4 IP Configuration Reset 4 Time Setting DHCP Server Backup and Restore Firmware Upgrade Cy Factory Default System Reboot The Web UI figure for Reset to Default Factory Default The following figure is the popup alert screen to confirm the command Click on Yes to reset the system Confimm Dialog The following UI is a popup message screen to show you that the reset is complete Click OK to close the screen Then go to the Reboot page to reboot the switch Success Message Reset to Deafault OK Please reboot switch to run factory configuration exclude IP address Click OK The system will then automatically reboot the device Note If you have already configured the IP of your device to another IP address when you use this command through CLI and Web UI our software will not reset the IP address to the default IP The system wil
3. SNMP Simple Network Management Protocol SNMP is a protocol used for exchanging management MANAGER information between network devices SNMP is a member of the TCP IP protocol suite JetNet 4706 4706f supports SNMP v1 v2c and v3 SNMP A SNMP managed network consists of two main components agents and a manager An agentis a management software module that resides in a Ki el managed switch An agent translates the local management information from the managed device S S a into a SNMP compatible format The manager is the console through the network Managed Device Managed Device The following commands are included in this section 4 8 1 SNMP Configuration 4 8 2 SNMP v3 Profile 4 8 2 SNMP Traps SNMP Configuration This allows users to configure the SNMP V1 V2c Community The community string can be viewed as a password because SNMP V1 V2c doesn t request you to enter a password before accessing the SNMP agent The community includes 2 privileges Read Only and Read and Write With Read Only privileges you will only have the ability to read the values in the MIB tables The default community string is set to Public With Read and Write privileges you will have the ability to read and set the values in the MIB tables The default community string is set to Private SNMP SNMP Y12c Community Community String zz Fead Only Ir Fead Only s Apply JetNet 4706 4706f allows users to assi
4. Current working status of the port Flow Control The state of the flow control 4 3 3 Rate Control Rate limiting is a form of flow control used to enforce a strict bandwidth limit of a port You can Disable Disable Disable Disable Disable Disable program separate trasmitting Egress Rule and receiving Ingress Rule rate limits for each port and even apply the limit to certain packet types as described below Rate Control Limit Packet Type and Rate 4 Broadcastony vea v a BroadcastOny vje 7 a Broadcastony j a Broadcastony vja a Broadcastony j e Broadcastony sla e Apply All no limit e al no lirnit sl Al no lirnit si Al no limnit sl Al no limit_ ai no lirnit gt JetNet 4706 4706f Industrial Managed PoE Switch 38 korenix Packet type You can select the packet type that you want to filter The packet types of the Ingress Rule incoming listed here include Broadcast Only Broadcast multicast Broadcast Multicast UnknownUnicast and All The packet types of the Egress Rule outgoing only support All packet types Rate This column allows you to manually assign the limit rate of the port Valid values support 128Kbps 256Kbps 512Kbps 1024Kbps 2048Kbps 4096Kbps and 8192Kbps To enable rate control function please click Apply to apply the configuration 4 3 4 Command Lines for Port Configuration Feature Port Control Port Control
5. Each switch fabric has a limited amount of space to write the learnt MAC address To save more entries for new MAC address the switch fabric will age out any unused MAC address entries with respect to the Aging Time The default Aging Time is 300 seconds The Aging Time can be modified on this page Static Unicast MAC Address For some applications users may need to type the static Unicast MAC address into its MAC address table On this page you can type in the MAC Address format XXXX XXXX XXXX and select its VID and Port ID Click on Add to add it to the MAC Address table MAC Address Table In the MAC Address Table you can see all the MAC Addresses learned by the switch fabric The packet types include Management Unicast Static Unicast Dynamic Unicast Static Multicast and Dynamic Multicast The table allows users to sort the addresses by the packet types and the port Packet Types Management Unicast refers to the MAC address of the switch It belongs to the CPU port only The Static Unicast MAC address can be added and deleted Dynamic Unicast MAC is the MAC address learned by the switch Fabric Static Multicast can be added through CLI and can be deleted through the Web and CLI Dynamic Multicast will appear after you have enabled IGMP and after the switch learns the IGMP report Click on Remove to remove the Static Unicast Multicast MAC address Click on Reload to refresh the table Newly learned Unicast Multicast MAC addresss
6. Enter the IP address of the target device you want to ping Ping Failure Reset Time Sec Enter the amount of time after ping has failed that you would like the relay output to turn off 10 40 Hold Time Sec Enter the amount of time after ping has failed and relay output has JetNet 4706 4 706f Industrial Managed PoE Switch Dry Output fi 92 168 10 100 73 Link Failure x BW korenix been turned off that you would like the relay output to be turned back on How to configure After selecting the Ping Failure event type the system will change the Relay Output to short state light the alarm LED and continuously ping the target device When the ping failure for Reset Time times out the system will change the Relay Output to open state and turn off the alarm LED for the amount of time entered in Hold Time After the Hold Time times out the system will start sending ping commands to the remote device Ex When the Reset Time is set to 10 sec while the Hold Time is set to 40 sec the following will occur After ping has failed after 10 seconds Reset Time the system will turn the Relay Output and Alarm LED off After 40 seconds Hold Time the system will turn the Relay Output and alarm LED on again The change of state of a Relay Output Ping Failure Event see the chart below os X of vi S uae S d O O Ka E Es E WE Start ping O S ao d 192 168 10 100
7. Re oS Ping Failure kd 2 ww 8 ak 192 168 10 100 K t ic Hold Time 40Sec Select Super Ring Failure When the Rapid Super Ring topology is changed the system will short Relay Out and light the alarm LED Super Ring Failure e Once you have finished configuring the settings click on Apply to apply your configuration JetNet 4706 4706f Industrial Managed PoE Switch 74 korenix 4 11 2 Event Selection Event Types are divided into 3 basic groups System Events Port Events and PoE Events System Events relate to the overall function of the switch whereas Port Events relate to the activity of specific ports Device Cold Start Power is cut off and then reconnected Device Warm Start Reboot the device by CLI or Web UI Power 1 Failure Power 1 is failure Power 2 Failure Power 2 is failure Authentication failure An incorrect password SNMP Community String is Time Synchronize Time Synchronize Failure Fault Relay The DO Fault Relay is on Super Ring Topology Master of Super Ring has changed or backup path is Changes activated ES Link Up The port is connected to another device Link Down The port is disconnected e g the cable is pulled out or the opposing devices turns down The PoE port is powering The PoE port is not powering JetNet 4706 4 706f Industrial Managed PoE Switch 15 korenix Warning Event Selection system Event Selection vi Device Cold S
8. Ring Port In a Rapid Super Ring environment you should have 2 Ring Ports Whether the switch is Ring Master or not when configuring RSR 2 ports should be selected to be Ring Ports After the Ring Master is selected one Ring Port will become the forwarding port and the other will become the blocking port at Jr Ring Port Pot w Version There are 2 versions provided with JetNet 4706 4 706f Version 1 Version 1 is Legacy Super Ring Client mode for users who need backward compatibility with JetNet 4000 4500 JetNet 4706 4706f supports Client mode only After connecting the Ring Ports to the JetNet 4000 4500 Super Ring switches the 2 Ring Ports can pass through the hello packets sent from the ring master of the Super Ring Then the ring master of the Super Ring can detect the link status well Version 2 Version 2 is Rapid Super Ring mode Version 2 is the default setting when you select the checkbox for Rapid Super Ring High End Switch Version 2 Version 1 Dual Homing Il Dual Homing II is an important feature of Korenix s 2 generation Ring redundancy technology When you want to connect multiple RSR or form redundant topology with other vendors Dual Homing II allows you to enable RSTP and RSR from one single device Thus you have more flexibility and a standard RSTP way of constructing your network topology As shown in the last figure you can enable RSTP and RSR from JetNet 4706 4706f at the s
9. State Port Control Auto Negotiation Port Control Force Speed Duplex Port Control Flow Control Port Status Switch config if shutdown gt Disable port state Port Link Change to DOWN interface fastethernet1 is shutdown now Switch config if no shutdown gt Enable port state Porti Link Change to DOWN Port Link Change to UP interface fastethernet1 is up now Switch config if Port Link Change to UP Switch config interface fa Switch config if auto negotiation Auto negotiation of port 1 is enabled Switch config if soeed 100 Po Link Change to DOWN set the speed mode ok Switch config if Port Link Change to UP Switch config if duplex full Port Link Change to DOWN set the duplex mode ok Switch config if Port Link Change to UP Switch config if flowcontrol on Flowcontrol on for port 1 set ok Switch config if flowcontrol off Flowcontrol off for port 1 set ok Switch show interface fat Interface fastethernett Administrative Status Enable Operating Status Connected Duplex Full Speed 100 Flow Control oft Default Port VLAN ID 1 39 korenix Ingress Filtering Disabled Acceptable Frame Type All Port Security Disabled Auto Negotiation Disable Loopback Mode None STP Status forwarding Default CoS Value for untagged packets is 0 Mdix mode is Disable Medium mode is Copper Note Administrative Status gt Port state of the port
10. ix iia supports 4 physical queues GE Ea EA E SN a ES Ea aa lowest low middle and high KZ jo 7i 37 37 37 o vho 7 37 i users should assign a DSCP value ETA nae viet Zei lee EE GE EE queve D sl ll sl sl sl sl sl s cen ott alc TT table to follow the upper layer 3 ouve 2 ve J 2 sl sl J2 l ll switch or routers DSCP setting ee e Te Lee Ur Le La a KEESCIESCHIESCHESCHIESCIESCHIESCHES _oscp s s so s s2 sa sa 55 After configuring press Apply to Queue 3 7 sl vie vle sl vik vie _oscp s s sa so eo o e2 oa aueue 3 l ell vll ll vik ll vli e J e t N et 4 70 6 Ge 4 70 6 f nd L Note Queue 3 is the highest priority queue 60 Apply i korenix enable the settings 4 7 4 CLI Commands for Traffic Prioritization Command Lines for Traffic Prioritization configuration QoS Setting Queue Scheduling etNet 4706 config qos queue sched Strict Priority sp Strict Priority wrr Weighted Round Robin Use an 8 4 2 1 weight etNet 4706 config qos queue sched sp lt Cr gt Queue Scheduling etNet 4706 config qos queue sched wrr WRR Port Setting priority etNet 4706 config interface fat Default Port Priority etNet 4706 config if qos priority DEFAULT PRIORITY Assign an priority 3 highest etNet 4706 config if qos cos 3 he default port priority value is set 3 ok Note When change the port setting you should Select the
11. port related settings in global configuration mode Exit Type exit or Ctrl Z to global configuration mode Type end to privileged EXEC mode VLAN Interface In this mode you can configure Enter Type interface VLAN Switch config vian Configuration settings for specific VLAN VID in global configuration mode Exit Type exit or Ctrl Z to global configuration mode Type end to privileged EXEC mode JetNet 4706 4 706f Industrial Managed PoE Switch 20 korenix Here are some useful commands for you to see all or specific commands available to you Save time and avoid typing errors Shows all the available commands in the mode you are currently in It also shows you the next command you can should type Switch config interface IFNAME Interface s name vlan Select a vlan to configure Character Shows all the available commands for what you input as Character Switch config a access list Add an access list entry administrator Administrator account setting arp Set a static ARP entry Tab Key Helps you input commands quicker If there is only one available command hitting the tab key can help you automatically generate the command Switch co tab tab Switch configure terminal Switch config ac tab Switch config access list Ctrl C Stops an unfinished command Ctrl S Locks the screen of the terminal You will not be able to input a command Ctrl Q Unlocks a locked scree
12. v Manual Setting User can select Manual setting to change time as user want and also click the icon Get Time From PC to sync time from your PC NTP client Select the Time Setting Source to NTP client can let device enable the NTP chent It allow JetNet4706 4706f get time from 2 different NTP servers The system will send request packet to acquire current time from the NTP server MTF Client Manual Setting NTF Client JetNet 4706 4706f Industrial Managed PoE Switch 25 korenix Time zone Select the time zone where the switch is located For your reference the following table lists the time zones of different locations The default time zone is GMT Greenwich Mean Time Switch config clock timezone GMT 12 00 Eniwetok Kwajalein GMT 11 00 Midway Island Samoa GMT 10 00 Hawaii GMT 09 00 Alaska GMT 08 00 Pacific Time US amp Canada Tijuana GMT 07 00 Arizona GMT 07 00 Mountain Time US amp Canada GMT 06 00 Central America GMT 06 00 Central Time US amp Canada GMT 06 00 Mexico City GMT 06 00 Saskatchewan GMT 05 00 Bogota Lima Quito GMT 05 00 Eastern Time US amp Canada GMT 05 00 Indiana East GMT 04 00 Atlantic Time Canada GMT 04 00 Caracas La Paz GMT 04 00 Santiago GMT 03 00 NewFoundland GMT 03 00 Brasilia GMT 03 00 Buenos Aires Georgetown GMT 03 00 Greenland GMT 02 00 Mid Atlantic GMT 01 00 Azores GMT 01 00 Cape Verde Is GMT Ca
13. 20 Network Redundancy It is critical for industrial applications for networks to continue working non stop JetNet 4706 4706f supports standard RSTP Rapid Super Ring Dual Homing II and Legacy Super Ring Client modes Rapid Super Ring RSR technology is Korenix s SZ generation Ring redundancy technology This is patented and protected by Korenix and is used in countries all over the world RSR ranks the fastest failover time in the world less than 5 milliseconds up to 20 units connected ina Gigabit Fiber Ring topology Advanced Dual Homing II technology also facilitates JetNet 4706 4 706fto connect with a core managed switch via standard Rapid Spanning Tree Protocol With Dual Homing II technology you can also run RSTP to couple several Rapid Super Rings which is also known as Auto Ring Coupling To become backwards compatible with the Legacy Super Ring technology implemented in JetNet 4000 4500 switches JetNet 4706 4706f also supports Super Ring Client mode The Super Ring ports can pass through Super Ring control packets extremely well and works with Super Ring Besides Korenix ring technology JetNet 4706 4706f also supports 802 1D 2004 version Rapid Spanning Tree Protocol RSTP The new version of RSTP standard includes 802 1D 1998 STP 802 1w RSTP The following commands are included in this section 4 5 1 RSTP 4 5 2 RSTP Info 4 5 3 Rapid Super Ring 4 5 4 Ring Info RSTP RSTP stands for Rapid Spanning Tree Protocol
14. 3 ManagedsSwitch config if switchport port based vlan egress ports fa2 fa3 Set port based vlan success switchport trunk native vlan VID ex assign VID 1 to port 1 ManagedsSwitch configure terminal ManagedSwitch config interface fa ManagedsSwitch config if switchport trunk native vlan 1 Set port default vlan id to 1 success ManagedSwitch config if switchport port based vlan mode untagged tagged unmodified ex Egress packet of port 1 with tagged ManagedsSwitch config if switchport port based vlan mode tagged Set port based vlan mode success 58 korenix 4 7 4 7 1 Traffic Prioritization Quality of Service QoS provides a traffic prioritization mechanism that allows users to deliver better service to certain flows QoS can also help to alleviate congestion problems and ensure that high priority traffic is delivered first This section allows you to configure Traffic Prioritization settings for each port in regards to setting priorities The JetNet 4706 4706f QoS supports 4 physical queues weighted fair queuing WRR and Strict Priority scheme which follows 802 1p COS tag and IPv4 TOS DiffServ information to prioritize the traffic of your industrial network The following commands are explained in this section 4 7 1 QoS Setting 4 7 2 CoS Queue Mapping 4 7 3 DSCP Queue Mapping QoS Setting QoS Setting Queue Scheduling Queue Scheduling Use an 8 4 2 1 weighted fair queuing Use an 8 4 2 1 weighted fair
15. 5 Appendix 5 1 Product Specifications Technology Standard Performance Switch Technology System Throughput MAC Address Packet Buffer Transfer performance Management interface SNMP MIB SNMP Trap System Log Class of Service Quality of Service DHCP Timer VLAN IGMP Network Redundancy Event Alarm Relay IEEE 802 3 10Base T IEEE 802 3 100Base TX IEEE 802 3 100Base FX IEEE 802 1p Class of Service IEEE 802 3af Power Over Ethernet IEEE 802 1d Spanning Tree IEEE 802 1w Rapid Spanning Tree Storing and forwarding technology with 3 2Gbps wire speed non blocking Switch Fabric 1 785Mpps 2000 Embedded 1Mbits shared buffer 14 880pps for Ethernet and 148 800 for Fast Ethernet and transfer packet size from 64 to 1522Bytes SNMP v1 v2c and v3 Web browser and Console Management RFC 1213 MIBII RFC 1493 Bridge MIB RFC 1757 RMON MIB RFC 2674 VLAN MIB RFC 1643 Ethernet like MIB RFC1215 Trap MIB RFC 3621 Power Ethernet MIB and Korenix Private MIB The SNMP trap agent provides Cold start Warm start Port event Power event Authentication failure PoE trap and Korenix private Trap for proprietary functions 1000 system entries for system or remote log server IEEE 802 1p class of service with 4 priority queues Quality of Service determined by port Tag and IPv4 Type of Service Supports DHCP Client and DHCP Server function with specified IP exclusion and MAC binding functions Supports Network Time Protoco
16. Aamin TN PortBased VLAN 1 200000000 128 e us Enable e e Bd Prioritization 2 onoon000 ize auto Enable CT Security 3 Tomm 128 ellain ell Enapie sl amp Clwammng a Banne 128 e la Enable e Sim oss rm TN Save 6 200000000 128 Auto Enable IN Logout apy RSTP Mode You must first enable STP RSTP mode before configuring any related parameters Parameter settings required for both STP and RSTP are the same Note that 802 1d refers to STP mode while 802 1w refers to faster RSTP mode AE De ein 1 Kr J Wie Bridge Configuration Priority 0 61440 RSTP uses bridge ID to determine the root bridge the bridge with the highest bridge ID becomes the root bridge The bridge ID is composed of bridge priority and bridge MAC address So that the bridge with the highest priority becomes the highest bridge ID If all of the bridge IDs have the same priority the bridge with the lowest MAC address will then become the root bridge Note The bridge priority value must be in multiples of 4096 A device with a lower number has a higher bridge priority Ex 4096 is higher than 32768 Max Age 6 40 Enter a value from 6 to 40 seconds here This value represents the time that a bridge will wait without receiving Spanning Tree Protocol configuration messages before attempting to reconfigure If JetNet 4706 4706f is not the root bridge and if it has not received a hello message from the root bridg
17. AutoDetected PointloPoint SharedLink EdgePort 9 Port Info etNet 4706 show spanning tree port detail fa7 Interface_ID Rapid Spanning Tree feature Enabled IEEE compatible Spanning Tree Protocol Enabled Spanning Tree BPDU transmission limit 3 Bridge identifier has priority 4096 address 0012 77ff 0102 Configured hello time 2 max age 10 forward delay 15 Current root has priority 4096 address 0012 7701 0386 Root port is 7 cost of root path is 200000 Topology change flag not set detected flag not set Number of topology changes 0 last change occurred from 0000 0000 0000 Times hello 2 max age 20 forward delay 15 Timers hello 0 topology change 0 Rapid Spanning Tree link type Shared Rapid Spanning Tree edge port Disabled Port 128 7 as Root Role is in Forwarding State Port Path Cost 200000 Port Identifier 128 7 Designated root has priority 4096 address 0012 7701 0386 Designated bridge has priority 4096 address 0012 7701 0386 Designated Port ID is 128 1 Root Path Cost is 0 Timers message age 4 sec forward delay 0 sec Forwarding State Transmit count 2 BPDU sent 624 received 3600 TCN sent 0 received 0 Rapid Super Ring etNet 4706 config super ring enable Super Ring Version etNet 4706 config Super ring version lt 1 2 gt valid range is 1 or 2 etNet 4706 config super ring version 2 Note 1 Super Ring 2 Rapid Super Ring etNet 4706 config super ring priority lt 0 255 gt valid range is 0 to 25
18. Disable Ring Status Normal State means the switch is running Rapid Super Ring well Abnormal State means RSR is enabled but is not running well The reason could be a ring port failure no neighbor switches etc Role Type Ring Manager or Redundancy Ring Information Manager l Ring Information Version 1 is Super Ring 2 is Rapid Super Ring Enable Abnormal state The other parameters are the same as the aes Redundancy Manager above descriptions E 2 5 6 128 1000 msec 1000 msec Dual Homing Il JetNet 4706 4706f Industrial Managed PoE Switch 52 korenix 4 5 5 Command Lines Enable Disable etNet 4706 config spanning tree disable arning STP disable will cause Dual Homing II not working RSTP mode etNet 4706 config spanning tree mode rapid stp panning Tree Mode change to be RSTP 802 1w STP mode etNet 4706 config spanning tree mode stp panning Tree Mode change to be STP 802 1d Priority etNet 4706 config spanning tree priority lt 0 61440 gt valid range is 0 to 61440 in multiple of 4096 etNet 4706 config spanning tree priority 4096 Max Age etNet 4706 config spanning tree max age lt 6 40 gt Valid range is 6 40 seconds etNet 4706 config spanning tree max age 10 Hello Time etNet 4706 config spanning tree hello time lt 1 10 gt Valid range is 1 10 seconds etNet 4706 config spanning tree hello time 2 Forward Delay etNet 4706 config spanning tree forward time lt 4 30 gt Valid range is 4 30
19. Display IGMP etNet 4706 sh ip igmp snooping Snooping Setting IGMP snooping is globally enabled Display IGMP Table etNet 4706 sh ip igmp snooping multicast all 239 192 8 0 IGMP JetNet 4706 4706f Industrial Managed PoE Switch 65 korenix Po SVL 239 255 255 250 IGMP fa6 IGMP Query IGMP Query V1 IGMP Query V2 IGMP Query version IGMP Query Interval IGMP Query Max Response Time Display etNet 4706 config int vlan 1 Go to management VLAN etNet 4706 config if ip igmp v1 etNet 4706 config int vlan 1 Go to management VLAN etNet 4706 config if ip igmp version 1 etNet 4706 config if ip igmp version 2 etNet 5010G config int vlan 1 Go to management VLAN etNet 5010G config if ip igmp etNet 5010G config if ip igmp query interval 60 Change query interval to 60 seconds default value is 125 seconds etNet 4706 config if ip igmp etNet 5010G config int vlan 1 Go to management VLAN etNet 5010G config if ip igmp etNet 5010G config if ip igmp query max response time 15 Change query max response time to 15 seconds default value is 10 seconds etNet 4706 config int vlan 1 etNet 4706 config if no ip igmp etNet 4706 sh ip igmp interface vlan1 enabled Yes version IGMPv2 query interval 125s query max response time 10s etNet 4706 show running config interface vian1 io address 192 168 10 17 24 ip igmp no shutdown 66 korenix 4 9 4 9 1
20. If DHCP Client function is enabled you don t need to assign the subnet mask The default Subnet Mask is 255 255 255 0 Note In the CLI we use the enabled subnet mask to represent the number displayed in the web UI For example 8 stands for 255 0 0 0 16 stands for 255 255 0 0 24 stands for 255 255 255 0 Gateway Assign the gateway for the switch The default gateway is 192 168 10 254 Note In the CLI we use 0 0 0 0 0 to represent the default gateway Once you finish configuring the settings click Apply to apply your configuration korenix 4 2 4 Time Setting Time Setting source allow user to set the time by manually or through NTP server It also provide time synchronize from PC Network Time Protocol NTP is used to synchronize computer clocks on the internet You can configure NTP settings here to synchronize the clocks of several switches on the network JetNet4706 4706f also provide Daylight Saving function CT ManagedSwitch IN System o CT Basic Setting ry Switch Setting System Time Sun Jan 1 00 02 49 2006 Cy Admin Password Manual Setting B IF Configuration Time Setting Get Time From PC oC OHCP Server Cy Backup and Restore i Firmware Upgrade B Factory Default B System Reboot o cI Por Configuration o c Metwork Redundancy o cI MAN o CC Traffic Prioritization o CT Multicast Filtering SNMP o CT Security Ed warning o CT Monitor and Diag TN Save D Logout Time Setting den Jl boe 7 o2
21. If a switch has more than one path to a destination it will lead to message loops that can generate broadcast storms and quickly bog down a network The spanning tree was created to combat the negative effects of message loops in switched networks A spanning tree uses a spanning tree algorithm STA to automatically sense whether a switch has more than one way to communicate with a node It will then select the best path primary and block the other path s It will also keep track of the blocked path s in case the primary path fails Soanning Tree Protocol STP introduced a standard method to accomplish this It is specified in IEEE 802 1D 1998 Later Rapid Spanning Tree Protocol RSTP was adopted and represents the evolution of STP providing for a much faster spanning tree convergence after a topology change This is specified in IEEE 802 1w In 2004 802 1w was 46 korenix included into the 802 1D 2004 version This switch supports both RSTP and STP all switches that support RSTP are also backwards compatible with switches that support only STP This page allows you to enable disable RSTP and configure the global setting and port settings me Rapid Spanning Tree Protocol EJ Basic Setting EJ Port Configuration RSTP Enable CJ Power over Ethernet Bridge Configuration IN PoE Control TN PoE Scheduling PoE Status CJ Network Redundancy RSTP TN RSTP Information Rapid Super Ring IN Ring Information CT VLAN
22. Operating Status gt Current status of the port Duplex gt Duplex mode of the port Speed gt Speed mode of the port Flow control gt Flow Control status of the port Rate Control egress Outgoing packets Ingress or Egress ingress Incoming packets Note To enable rate control you should select the Ingress or Egress rule first then assign the packet type and bandwidth Rate Control Filter JetNet 4706 config if rate limit ingress mode all Limit all frames Packet Type broadcast Limit Broadcast frames flooded unicast Limit Broadcast Multicast and flooded unicast frames multicast Limit Broadcast and Multicast frames JetNet 4706 config if rate limit ingress mode broadcast Set the ingress limit mode broadcast ok Rate Control JetNet 4706 config if rate limit ingress bandwidth lt 0 100 gt Limit in magabits per second 0 is no limit Bandwidth JetNet 4706 config if rate limit ingress bandwidth 8 Set the ingress rate limit 8Mbps for Port 1 4 4 Power over Ethernet Power over Ethernet is one of the key features of JetNet 4706 4 706f It is in compliances with IEEE 802 3af standards and supports 30w High power forwarding capability JetNet 4706 4 706f adopts 4 Port PoE injectors in port 1 to port 4 each port with the ability to deliver a 0 615mA Current The following commands are included in this section 4 4 1 PoE Control 4 4 2 PoE Scheduling 4 4 3 PoE Status 4 4 4 Command Line for PoE control 40 ko
23. SNMP EJ Security amp EJ warning CJ Monitor and Diag Figure 4 2 1 1 JetNet 4706 c OIL 1 5 6 1 2 24062 27 1 3 JetNet 4706 Industrial Managed Switch vU UO 20070514 00 12 77 0300 JetNet 4706 4706f Industrial Managed PoE Switch 22 korenix 4 2 2 System Name Assign a name to the device You can input up to 64 characters After you configure the name the CLIP system will select the first 12 characters as the name for the CLIP system System Location Specify the switch s physical location You can input up to 64 characters System Contact Specify contact people Type in the name e mail address or other information about the administrator You can input up to 64 characters System OID Set the SNMP object ID of the switch You can follow the path to find its private MIB in the MIB browser Note When you attempt to view a private MIB you should compile private MIB files into your MIB browser first System Description View a description of the system JetNet 4706 4 706f Industrial Management Ethernet Switch is the name of this product Firmware Version Display the firmware version installed on this device MAC Address Display the unique hardware address MAC address assigned by the manufacturer Once you have finished the configuration click Apply to apply your settings Note Always remember to select Save to save your settings Otherwise the settings you made will be lost when the switch is powered
24. Save Configuration will cause loss of new settings After selecting Save Configuration click on Save to Flash to save your new configuration EI JetNeta706 Save to Flash Ly System EJ Basic Setting amp J Port Configuration Note This command will permanently save the current configuration to flash o CT Power over Ethernet Network Redundancy Gd VLAN Ei Traffic Prioritization J Multicast Filtering e CH SNMP e CT Security e Gd Warning 1 Monitor and Diag B Device Front Panel Save Cy Logout Save to Flash JetNet 4706 write Building Configuration OK Switch copy running config startup config Building Configuration OK JetNet 4706 4706f Industrial Managed PoE Switch 86 korenix 4 15 Logout The switch provides 2 logout methods Your web connection will log out if you do not input a command for 30 seconds The Logout command allows you to manually log out the web connection Click on Yes to logout and No to go back to the configuration page i Firmware Upgrade Cy Factory Default IN System Reboot amp CH Port Configuration CT Power over Ethernet Gr CH Network Redundancy CH VLAN C Trafic Prioritization GC SNMP Gr E Security E Warning amp Monitor and Diag Ci Device Front Pane IN Save Th Logout Confimm Dialog Command Lines JetNet 4706 gt exit JetNet 4706 exit JetNet 4706 4706f Industrial Managed PoE Switch 87 korenix
25. damaged please contact your local sales representative korenix 2 Hardware Installation The following topics are covered in this chapter 2 1 Hardware Introduction Dimensions Panel Layout Bottom View 2 2 Wiring Power Inputs 2 3 Wiring Digital Input 2 4 Wiring Relay Output 2 5 Wiring Fast Ethernet Ports 2 6 Wiring Combo Ports 2 7 Wiring RS 232 console cable and pin assignment 2 8 DIN Rail Mounting Installation 2 9 Wall Mount Installation 2 1 Hardware Introduction Dimensions JetNet 4706 4706f Industrial Gigabit Switch dimensions 174 8mmW x 46 5mmH x 136mmD 6 98 W x 1 82 H x 5 31 D JetNet 4706 4706f Industrial Managed PoE Switch korenix Mylar Layout There is one Mylar stick on the top side of the JetNet 4706 4706f It includes four LEDs for the system alarm power and Ring Master and ten LEDs for the port operating status For details please check the following figure Mylar Layout PoE LNK ACT Alm Oi PMiOm2020 60 PWO g AC RM O40 40 Mylar Layout Port Layout JetNet 4706 4706f includes 4 Port 10 100TX with embedded PoE injector function in ports 1 4 each PoE port can deliver a maximum of 30w There is also 1 reset button and 1 console port in RJ 45 type connector JetNet 4706 comes with 2 Port 10 100Base TX for uplink JetNet 4706f comes with 2 Port Fiber 100Base FX See the following figures JetNet 4706 Hemen L JetNet 4706f JetNet 4706 4706f Industrial Managed PoE Swi
26. limit power manual 12 Parameters Weekday Valid range 0 6 O Sunday 1 Monday 6 Saturday Hour Valid range 0 23 Valid format a b c d Command Mode Interface mode Description Add a day schedule to an interface Examples Add a schedule which enables PoE function at hour 1 3 5 and 10 to 23 on Sunday Switch config if poe schedule 0 1 3 5 10 23 Parameters Weekday Valid range 0 6 O Sunday 1 Monday 6 Saturday Command Mode Interface mode Description Remove a day schedule Examples Remove the Sunday schedule Switch config if no poe schedule 0 Parameters enable enable PD Status Detection function disable disable PD Status Detection function Command Mode Configuration mode Description Enable Disable the PD Status Detection function Examples To enable the function of pd status detect function Switch config poe pd_detect enable To disable the function of pd status detect function Switch configf poe pd_detect disable JetNet 4706 4706f Industrial Managed PoE Switch 45 korenix 4 5 4 5 1 Syntax poe pd_detect ip_address cycle_time Parameters IP address A B C D Cycle time Valid range 10 3600 second and must be multiple of 10 Command Mode Configuration mode Description Apply a rule of PD Status Detection Examples Apply a rule which ping 192 160 1 2 per 20 seconds And if 192 160 1 2 is timeout pd status detection will re enable the PoE Switch config poe pd_detect 192 160 1 2
27. map priority_value queue_value Map CoS 0 to Queue 1 JetNet 4706 config qos cos map 0 1 The CoS to queue mapping is set ok Map CoS 1 to Queue 0 JetNet 4706 config gos cos map 1 0 The CoS to queue mapping is set ok Map CoS 2 to Queue 0 JetNet 4706 config gos cos map 2 0 The CoS to queue mapping is set ok Map CoS 3 to Queue 1 JetNet 4706 config qos cos map 3 1 The CoS to queue mapping is set ok Map CoS 4 to Queue 2 JetNet 4706 config qos cos map 4 2 The CoS to queue mapping is set ok Map CoS 5 to Queue 2 JetNet 4706 config qos cos map 5 2 The CoS to queue mapping is set ok Map CoS 6 to Queue 3 JetNet 4706 config gos cos map 6 3 The CoS to queue mapping is set ok Map CoS 7 to Queue 3 JetNet 4706 config qos cos map 7 3 The CoS to queue mapping is set ok Display CoS Queue JetNet 4706 sh gos cos map mapping CoS to Queue Mapping CoS Queue WWNMNN OO DSCP Queue Mapping Format etNet 4706 config qos dscp map PRIORITY Assign an priority 63 highest etNet 4706 config qos dscp map 0 QUEUE Assign an queue 0 3 Format qos dscp map priority_value queue_value 62 korenix a Map DSCP 0 to Queue JetNet 4706 config qos dscp map 0 1 1 The TOS DSCP to queue mapping is set ok Display DSCO Queue JetNet 4706 show qos dscp map mapping DSCP to Queue Mapping dscp d1 d2 d2 0123456789 0 1111111100 1 0000000000 210000111111 S111 22022220 4 2222222233 5 3333333333 6 33
28. off Admin Password You can change the username and password to enhance security The following figure is the Web UI for Admin Password Admin Password a Username Key in a new username The default setting is admin Password Key in a new password The default setting is admin Confirm Password Re enter the new password to confirm it Once you finish configuring the settings click Apply to apply your configuration korenix The following figure is the popup alert window when the incorrect username is entered Eror Messaze YTY Connect and Login Failed gt admin 4 2 3 IP Configuration This function allows users to configure the switch s IP address settings IP Configuration DHCP Client Disable fi 92 168 10 1 255 255 255 0 E 92 168 10 254 a DHCP Client Enable or Disable DHCP Client function When DHCP Client function is enabled an IP address will be assigned to the switch from the network s DHCP server In this mode the default IP address will be replaced by the one assigned by the DHCP server If DHCP Client is disabled then the IP address that you specified will be used instead IP Address You can assign the IP address reserved by your network for your JetNet If DHCP Client function is enabled you don t need to assign an IP address as it will be overwritten by the DHCP server The default IP address is 192 168 10 1 Subnet Mask Assign the subnet mask for the IP address
29. seconds etNet 4706 config spanning tree forward time 15 Port Path Cost etNet 4706 config if spanning tree cost lt 1 200000000 gt 16 bit based value range from 1 65535 32 bit based value range from 1 200 000 000 etNet 4706 config if spanning tree cost 200000 Port Priority etNet 4706 config if spanning tree port priority lt 0 240 gt Number from 0 to 240 in multiple of 16 etNet 4706 config if spanning tree port priority 128 Link Type Auto Link Type P2P Link Type Share Edge Port etNet 4706 config if spanning tree edge port enable etNet 4706 config if spanning tree edge port disable Active status etNet 4706 show spanning tree active Rapid Spanning Tree feature Enabled Spanning Tree BPDU transmission limit 3 Root Address 0012 7701 0386 Priority 4096 Root Path Cost 200000 Root Port 7 Root Times max age 20 sec hello time 2 sec forward delay 15 sec Bridge Address 0012 77ff 0102 Priority 4096 Bridge Times max age 10 sec hello time 2 sec forward delay 15 sec Aging time 300 Role Port State Cost Prio Nbr Type Designated Forwarding 200000 128 6 Auto RST fa7 Root Forwarding 200000 128 7 Shared STP korenix RSTP Summary etNet 4706 show spanning tree summary witch is in rapid stp mode BPDU skewing detection disabled for the bridge Backbonefast disabled for bridge ummary of connected spanning tree ports Port State Summary Blocking Listening Learning Forwarding Disabled 8
30. shall be free of defects in materials and workmanship for a period of five 5 years from the date of delivery provided that the product was properly installed and used This warranty is void if defects malfunctions or failures of the warranted product are caused by damage resulting from forced measures such as floods fire etc environmental and atmospheric disturbances other external forces such as power line disturbances host computer malfunction plugging the board in under power or incorrect cabling or if the warranted product is misused abused or operated altered and repaired in an unauthorized or improper way Korenix Technologies Co Ltd 5F No 98 1 Ming Chuan Rd Shing Tien City Taipei Taiwan Tel 886 2 8219 3000 Fax 886 2 8219 3300 Business service sales korenix com Customer service koreCARE korenix com 93
31. specific port first Ex fa1 means fast Ethernet port 1 Port Setting Trust etNet 4706 config interface fat Mode CoS Only etNet 4706 config if qos trust cos he port trust is set CoS only ok Port Setting Trust etNet 4706 config interface fat Mode CoS Frist etNet 4706 config if qos trust cos first he port trust is set CoS first ok Port Setting Trust etNet 4706 config interface fat Mode DSCP Only etNet 4706 config if gos trust dscp he port trust is set DSCP only ok Port Setting Trust etNet 4706 config interface fat Mode DSCP First etNet 4706 config if qos trust dscp first he port trust is set DSCP first ok Port Setting Trust etNet 4706 config interface fat Mode Port Based etNet 4706 config if qos trust port based he port trust is set port based ok etNet 4706 show qos queue sched Scheduling QoS queue scheduling scheme Weighted Round Robin Use an 8 4 2 1 weight Display Port Setting JetNet 4706 show qos trust Trust Mode QoS Port Trust Mode Port Trust Mode DSCP first COS only COS only COS only COS only COS only COS only COS only CONOR WND 61 korenix Pt e Display Port Setting JetNet 4706 show qos port cos CoS Port Default Port Default Cos Priority Port CoS CoS Queue Mapping etNet 4706 config qos cos map PRIORITY Assign an priority 7 highest etNet 4706 config qos cos map 1 QUEUE Assign an queue 0 3 Note Format qos cos
32. timezone you want to select Display JetNet 4706 sh ntp associations 1 192 168 10 100 2 192 168 10 101 JetNet 4706 show clock Sun Jan 1 04 14 19 2006 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London JetNet 4706 show clock timezone clock timezone 26 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London Backup and Restore Backup Startup Switch copy startup config tftp 192 168 10 33 ue Writing Configuration OK Configuration file Note 1 To backup the latest startup configuration file you should save current settings to flash first You can refer to 4 12 to see how to save settings to the flash Note 2 192 168 10 33 is the TFTP server s IP Your environment may use different IP addresses Please type target TF TP server IP in this command Show Startup Switch show startup config Configuration Show Running Switch show running config Configuration Firmware Upgrade Firmware Upgrade Switch archive download sw overwrite tftp 192 168 10 33 JetNet 4706 bin Firmware upgrading don t turn off the switch Tftping file JetNet 4706 bin Firmware upgrading Firmware upgrade success Rebooting Factory Default Factory Default Switch reload default config file Reload OK Switch reboot System Reboot Reboot Switch reboot 36 korenix 4 3 4 3 1 Port Configuration This section shows you how to enable disable port state or configure port auto negotiation speed duplex fl
33. 0 00 Brisbane 67 GMT 10 00 Canberra Melbourne Sydney 68 GMT 10 00 Guam Port Moresby 69 GMT 10 00 Hobart 70 GMT 10 00 Vladivostok 71 GMT 11 00 Magadan Solomon Is New Caledonia 72 GMT 12 00 Aukland Wellington 73 GMT 12 00 Fiji Kamchatka Marshall Is GMT 13 00 Nuku alofa Daylight Saving Time Set when Enable Daylight Saving Time start and end During the Daylight Saving Time the device s time is one hour earlier than the actual time Once you have finished the configuration click Apply to apply your configuration 4 2 5 DHCP Server You can select to Enable or Disable DHCP Server function JetNet 4706 4706f will assign a new IP address to link partners DHCP Server configuration DHCP Server Enable After selecting to enable DHCP Server function l type in the Network IP address for the DHCP DHCP Server Configuration server IP pool Subnet Mask Default Gateway address and Lease Time for client eose JetNet 4706 4706f Industrial Managed PoE Switch 27 korenix L Once you have finished the configuration click Apply to apply your configuration 1 HE Excluded Address You can type a specific address into the IP Address field for the DHCP server reserved IP address The IP address that is listed in the Excluded Address List Table will not be assigned to the network device Add or remove an IP address from the Excluded Address List by clicking Add or Remove Excluded Addres
34. 1 Warning 4 12 Monitor and Diag 4 13 Device Front Panel 4 14 Save to Flash 4 15 Logout 16 korenix 4 1 Command Line Interface CLI Introduction The Command Line Interface CLI is the user interface of the switch s embedded software system You can view the system information see the status configure the switch and receive a response back from the system by keying in a command There are different command modes Each command mode has its own access ability its own available command lines and its own different command lines to enter and exit These modes are User EXEC Privileged EXEC Global Configuration and Port VLAN Interface Configuration modes User EXEC mode As long as you login to the switch through CLI you will be in the User EXEC mode You can ping telnet remote device and show some basic information Types enable to enter the next mode and exit to logout Below is a full command list JetNet 4706 gt enable Turn on privileged mode command exit Exit current mode and down to previous mode list Print command list ping send echo messages quit Exit current mode and down to previous mode show Show running system information telnet Open a telnet connection traceroute Trace route to destination Privileged EXEC mode Type enable in the User EXEC mode to enter the Privileged EXEC mode In this mode the system allows you to view current configurations reset to default reload the switch show the syst
35. 10 33 without specific SNMP trap host add OK community name SNMP Trap Server IP etNet 4706 config snmp server host 192 168 10 33 with version 1 and version 1 private community SNMP trap host add OK Note private is the community name version 1 Is the SNMP version SNMP Trap Server IP etNet 4706 config snmp server host 192 168 10 33 with version 2 and version 2 private community SNMP trap host add OK Disable SNMP Trap etNet 4706 config no snmp server enable trap et SNMP trap disable ok Display etNet 4706 sh snmp server trap NMP trap Enabled NMP trap community public etNet 4706 show running config Snmp server community public ro Snmp server community private rw Snmp server enable trap Snmp server host 192 168 10 33 version 2 admin Snmp server host 192 168 10 33 version 1 admin 70 korenix 4 10 Security In the IP Security section you will be able to set up specific IP addresses to perform authorization for management access to JetNet 4706 4706f via web browser Telnet or SNMP Once you have finished configuring the IP Security settings click on Apply Add to apply your configuration IP Security Enable e Apply 4 10 1 IP Security Add Security IP You can assign any PC as an administrator workstation by adding a PC s IP address into the Security IP field Only these IP addresses will be able to access and manage JetNet 4706 4706f The maximum security IP is 10 Security IP List This table sho
36. 3 4 5 6 7 8 19 20 21 22 23 Friday 0 1 2 3 4 5 6 7 8 19 20 21 22 23 Saturday 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Parameters user user mode schedule schedule mode Command Mode Interface mode Description Set the control mode of port Examples Set PoE port 2 to user mode EX 1 JetNet 4706 config interface fa2 JetNet 4706 config if poe control mode user Set PoE port 2 to schedule mode EX 2 JetNet 4706 config if poe control mode schedule Parameters enable enable port in user mode disable disable port in user mode Command Mode Interface mode Description Enable Disable the PoE of the port in user mode If in schedule mode it will come into affect when the control mode JetNet 4706 4706f Industrial Managed PoE Switch 44 korenix changes to user mode Examples To enable the PoE function in user mode Switch config if poe user enable To disable the PoE function in user mode Switch config if poe user disable Parameters Standard Standard 802 3af mode Manual Manual mode Ultra Ultra mode POWER 802 3af mode N A Manual mode 0 44 15 4 Ultra mode 0 44 30 Command Mode Interface mode Description Set the mode and the max value of power consumption Examples Set the mode to standard 802 3af Ps There is no POWER parameter in standard mode Switch config if poe limit power standard Set the max value of power consumption to 12 W with manual mode Switch config if poe
37. 33 4 8 Multicast Filtering For multicast filtering JetNet 4706 4706f uses IGMP Snooping technology The IGMP Internet Group Management Protocol is an Internet Protocol that provides a way for an internet device to report its multicast group membership to adjacent routers Multicasting allows one computer on the internet to send data to a multitude of other computers that have identified themselves as being interested in receiving the originating computers data Multicasting is useful for such applications as updating the address books of mobile computer users in the field sending out newsletters to a distribution list and broadcasting streaming media to an audience that has tuned into the event by setting up multicast group membership In effect IGMP Snooping manages multicast traffic by making use of switches routers and hosts that support IGMP Enabling IGMP Snooping allows the ports to detect IGMP queries report packets and manage multicast traffic through the switch IGMP has three fundamental types of messages as shown below A message sent from the querier an IGMP router or a switch which asks for a response from each host that belongs to the multicast group A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message A message sent by a host to the querier to indicate that the host has quit as a member of a specific multicast group Y
38. 5 etNet 4706 config super ring priority 100 Ring Port etNet 4706 config super ring port IFLIST Interface list ex fa1 fa3 5 gi8 10 etNet 4706 config super ring port fal fa2 etNet 4706 config super ring dual homing enable etNet 4706 config super ring dual homing disable _Ring Info Ring Info etNet 4706 show super ring summary uper Ring protocol status Enable korenix Ring state Abnormal state Role type Redundancy Manager Protocol Version 2 Ring Port fa1 fa2 Switch Priority 100 Hello time 1000 msec Operate hello time 1000 msec Dual Homing IlI status Enable uper Ring Statistics of Switch WPDU sent 0 received 0 TCN sent 0 received 0 Ring State Transmit count 0 Role Type Transmit count 3 55 korenix 4 6 4 6 1 4 6 2 VLAN JetNet 4706 4706f supports Port Based VLAN functionality for the purpose of limiting a broadcast domain to specific members of a group by physically grouping the members together JetNet 4706 4706f determines the membership of a data frame by examining the configuration of the port that received the transmission or by reading a portion of the data frame s tag header A four byte field in the header is used to identify the VLAN This VLAN identification indicates which VLAN the frame belongs to If the frame has no tag header the switch checks the VLAN setting of the port that received the frame If the switch has been configured for port based VLAN suppor
39. 706 4706f is the best choice korenix Product Features 1 3 The Korenix JetNet 4706 4 706f has the following features SNMP Web Console Management and JetView Windows Utility 4 10 100TX with PoE injector 2 Port 10 100Base TX for uplink JetNet 4706 2 Port Fiber 100Base FX for uplink JetNet 4706f IEEE 802 3af Power over Ethernet compliance Supports PoE 30W High Power on each PoE Port End Span PoE wiring architecture with 4 5 7 8 powering Pins Provides Scheduling PoE Power Control Active Link Partner Live Detect LPFD function DC48V or DC24V PoE System Redundancy power function Over current protection Rapid Super Ring within 20ms Network backup time Ring Coupling Dual Homing IEEE 802 1D RSTP Port Based VLAN IEEE 802 1p class of service and TOS DiffServ QoS Rate Control and Flow Control IGMP Snooping and IGMP query DHCP Client Server IP31 aluminum housing for improved thermal radiation 10 60 C 14 140 F operating temperature for hazardous environments 1 2KV Hi Pot testing passed IEEE standard compliance Note Detailed specifications are listed in Appendix 5 1 Package Checklist The Korenix JetNet 4706 4 706f includes the following items One Industrial Managed PoE switch JetNet 4706 or JetNet 4706f One DIN Rail clip One wall mounting plate and screws One RS 232 DB 9 to RJ 45 console cable Documentation and Software CD Quick Installation Guide If any of the above items are missing or
40. 706f Industrial Managed PoE Switch 49 korenix Rapid Super Ring w version 2 versinn Apply This page allows you to enable the settings for Rapid Super Ring and Dual Homing II Rapid Super Ring The checkbox seen below is for you to enable the Rapid Super Ring Enable this and then configure Priority for the Ring Master selection Select Ring ports for primary and backup path and super ring version Ring Master R M In the Rapid Super Ring environment you should have one Ring Master The ring master has the rights to negotiate and decide the forwarding port and blocking port of the ring One of the ring ports will become the blocking port to prevent data loop from happening When detecting a topology change the ring master will automatically change the blocking port to forwarding so that traffic transmission will not be terminated Unlike JetNet 4000 4500 there is no additional DIP switch to enable the Ring Master function in JetNet 4706 4706f But provides Priority parameter for the Ring Master election Priority The switch with the highest priority lowest value will be automatically selected as the Ring Master Then one of the ring ports in this switch will become the Forwarding port with the other becoming the Blocking port If all of the switches have the same priority the switch with the lowest MAC address will be selected as the Ring Master JetNet 4706 4706f Industrial Managed PoE Switch 50 korenix
41. EN BE elle euer e EE 88 5 2 Pin Assignment for RS 232 ConsoleCGabie 90 5 3 EES EE Ge MIB aissius EE 90 HA REVISION HISO EE 92 55 e OOK ee veces ea Ge 93 korenix 1 1 Introduction Welcome to the Korenix JetNet 4706 4706f Industrial Managed Power over Ethernet PoE Switch User Manual The following topics are covered in this chapter 1 1 Overview 1 2 Product Features 1 3 Package Checklist Overview The Korenix JetNet 4706 4706f is a 6 port Fast Ethernet Industrial Managed Switch with 4 Port Power over Ethernet injector 10 100Base TX JetNet 4706 features 2 Port 10 100Base TX for uplink JetNet 4706f features 2 Port Fiber 100Base FX for long haul connection Fiber provides 30km link ability for single mode fiber or 2km link ability for multi mode fiber JetNet 4706 4706f is in compliance with IEEE 802 3af Power over Ethernet standards and provides 30W PoE high power forwarding capability In order to apply to a non standard power source system JetNet 4706 4706f is equipped with dual mode PoE powering mechanisms which detects power voltage and executes different powering and disconnecting processes This feature is suitable for DC24V transit power systems or any application without a DC48V power source The additional 2 Port allows users to extend network infrastructure for any uplink or connection as redundant ring architecture with nonstop transmission mechanism Rapid Super Ring RSR The RSR function provides network red
42. ES ES 9 Click OK The welcome page of the web based management interface will now appear 11 korenix korenix JETA CI Jetnets7o6 System E Basic Setting 2 EJ Port Configuration EJ Power over Ethernet EJ Network Redundancy amp CI VLAN E Traffic Prioritization Gr CJ SNMP CT Security Gr EJ warning C Monitor and Diag 4 Device Front Panel IN Save Logout Your Industrial Computing amp Networking Partner Welcome to the JetNet 4706 Industrial Managed Switch JetNet 4706 1 5 6 1 2 24062 2 1 3 Jet et 4706 Industrial Managed Switch v UO 20070514 DUT A CTT U2 00 Copyright CH 2006 Korenix Technology Co Ltd All Rights Reserved 10 Once you enter the web based management interface you can change the JetNet 4706 4706fs IP address to fit your network environment Note 1 Internet Explorer Version 5 0 or later does not allow Java applets to open sockets by default Users must directly modify the browser settings to selectively enable Java applets in order to use network ports Note 2 The Web UI connection session of JetNet 4706 4706f will logout automatically if you do not input anything after 30 seconds Re login if this occurs 3 2 2 Secured Web Interface The Korenix web management page also provides a secure HTTPS login All the configuration commands will be secure making it hard for hackers to figure out login password and configuration commands 1 Launch a web
43. Out band management is not affected by network performance In band management allows you to remotely manage the switch via the network You can choose Telnet or Web based management You just need to know the device s IP address and you can remotely connect to its embedded HTTP web pages or Telnet console The following topics are covered in this chapter 3 1 Preparation for Serial Console 3 2 Preparation for Web Interface 3 3 Preparation for Telnet console Preparation for Serial Console In the JetNet 4706 4706f package Korenix has included one RS 232 DB 9 to RJ 45 console cable Attach the RS 232 DB 9 connector to your PC COM port then connect the RJ 45 to the console port of JetNet 4706 4706 If you lose the cable please follow the console cable Pin assignment to find one See Appendix 1 Go to Start gt Program gt Accessories gt Communication gt Hyper Terminal 2 Give aname to the new console connection 3 Choose the COM name 4 Select correct serial settings The serial settings for the JetNet 4706 4706f are Baud Rate 9600 Parity Check None Data Bit 8 Stop Bit 1 After connected you will see a switch login request Login to the switch The default username and password are admin Booting Switch login admin Password JetNet 4706 version 0 30 20061 211 Copyright 2006 2010 Korenix Technology Co Ltd Switch gt 10 korenix 3 2 3 2 1 Preparation for Web Interface Th
44. PoE Switch the JetNet 4706 4706f PoE Switch will turn off and turn on the PoE power to emulate the PD reset function The LPLD function saves time and makes the PoE PD more reliable 4 x 10 100Base TX with PoE Injector 2 x 10 100Base TX port for JetNet 4706 2 x 100Base FX port for JetNet 4706f 1 x RS 232 Console 10 100Base TX RJ 45 100Base FX SC Console RJ 45 6 pin Terminal Block Power amp Relay Alarm End Span wiring architecture PD classification detection class ID 0 3 for IEEE 802 3af standard and 30W High power deliver procedures for class ID 4 Pin assignment V RJ 45 Pin 4 5 V RJ 45 Pin 7 8 TX RJ 45 Pin 1 2 RX RJ 45 Pin 3 6 Protection Provides Over current protection by PD class 10Base T 4 pair UTP STP Cat 3 5e 6 cable EIA TIA 568 B 2 100 ohm up to 100m 100Base TX 4 pair UTP STP Cat 5e 6 cable EIA TIA 568 B 2 100 ohm up to 100m For system reboot and factory default setting Power LED Power 1 Power 2 Green Fast Ethernet Port 1 4 Link Green Activity Green blinking PoE Powering Yellow on PoE Detect Yellow blinking PoE Disable Yellow off PoE Powering fail Yellow fast blinking Fast Ethernet Port 5 6 Link Green Activity Green blinking Alarm Red Port link down or power failure occurred Supports positive or negative power system with DC 24 55V power input range and polarity reverse protection 8 Watts 48V Maximum without PD loading DIN Rail mount or des
45. ame time Then the JetNet 4706 4706f ring can be protected by Rapid Super Ring while the connection to the other vendors can be protected by RSTP In Dual Homing which was released with JetNet 4000 4500 you had to configure additional ports as a Dual Homing port to 2 uplink switches However in Dual Homing II you no longer need to configure a specific port to connect to another protocol Just by keeping RSTP enabled Dual Homing II will be able to make the connection and be protected by standard RSTP Once you finish configuring the settings click Apply to apply your configuration JetNet 4706 4706f Industrial Managed PoE Switch 51 korenix 4 5 4 Auto Ring Coupling With JetNet 4000 4500 we released Ring Coupling for users to couple 2 Super Rings In JetNet 4706 4706f we use Dual Homing II to meet the same requirements JetNet 4706 4706f s rings are protected by Rapid Super Ring with RSTP amp RSR enabled in intermediate switches There is no need to configure Couple Ring ports You can freely connect Rapid Super Rings and all the Rapid Super Rings can be protected by Dual Homing II This is called Auto Ring Coupling You can connect 2 or more Rapid Super Rings with ease The following chart is an example of auto ring coupling Note These are not commands to enable Auto Ring Coupling You just need to enable RSTP and RSR for the same device Ring Information This page shows RSR information Protocol Status Enable or
46. are the selections you can choose Fast Ethernet Port 1 6 fa1 fa6 Auto Negotiation 10M Full Duplex 10 Full 10M Half Duplex 10 Half 100M Full Duplex 100 Full and 100M Half Duplex 100 Half The default mode is Auto Negotiation mode Flow Control column Enable or disable the flow control function Enable means that you need to activate the flow control function of the remote network device in order to let the flow control of that corresponding port on the switch to work Disable means that you do not need to activate the flow control function of the remote network device as the flow control of that corresponding port on the switch will work either way korenix Once you have finished configuring the settings click Apply to save the configuration Technical Tips If both ends are going at different speeds they will not link to each other If both ends are in different duplex modes they will be connected by half mode 4 3 2 Port Status Port Status shows you the current port status Port Status 1 OOBASE Down Enable 100BASE Down Enable 100BASE Down Enable 100BASE Down Enable 1 OOBASE Tx Lp Enable 100 Full 100BASE Down Enable A description of each column is as follows Port Port interface number Type 100BASE gt Fast Ethernet port Link Link status Up gt Link UP Down gt Link Down State Enable gt State is enabled Disable gt The port is disable by user configured Speed Duplex
47. browser Internet Explorer or Mozilla FireFox on your PC 2 Type https 192 168 10 1 or the IP address of the switch into the web address window Press Enter 3 A popup screen will appear and request you to trust the secure HTTPS connection distributed by JetNet 4706 4706f Press Yes The login screen will appear next Key in the username and password The default username and password are admin 6 Click OK The welcome page of the web based management interface will now appear JetNet 4706 4706f Industrial Managed PoE Switch 12 korenix 3 3 3 3 1 3 3 2 Eorenix JetWet4 706 Switch Manager Please enter user name and password Site 192 168 10 1 User Name admin Password Ee Secure Connection ES 7 Once you enter the web based management interface all the commands you see will be the same as what appeared through HTTP login Preparation for Telnet Console Telnet The Korenix JetNet 4706 4706f supports Telnet You can connect to the switch through Telnet the command lines are the same as the RS232 console port Below are the steps for opening a Telnet connection 1 Go to Start gt Run gt cmd Press Enter 2 Type Telnet 192 168 10 1 or the IP address of the switch Press Enter SSH Secure Shell The Korenix JetNet 4706 4706f also supports SSH You can remotely connect to the switch by command line interface The SSH connection can secure all the configuration commands yo
48. ctly use the private MIB to manage monitor the switch there is no need to learn where the OIDs of the commands are The path of JetNet 4706 4706f is 1 3 6 1 4 1 24062 2 1 4 Below is the Private MIB tree for your reference MIB Tree 1 cc Ge directory fam mamit 1 experimental a D ya t e apstemlnfo basicSetting portlontiguration poe nnghedundancy vlan trafficPriontization roulticastF deng shimp Security waming montorndOiag Save 91 korenix 5 4 Revision History Edition Date Modifications V0 1 23 Jun 2007 First version V0 2 10 Sep 2007 Second version JetNet 4706 4 706f Industrial Managed PoE Switch korenix 5 5 About Korenix Save Time and Money On Applications The Korenix business plan is to let you spend less time at work and a smaller budget on your applications Many people find themselves going through a lot of trouble to end up with low quality products and bad service This is why Korenix is here Korenix offers a complete selection of products that fulfill all your application needs We provide easier faster customized services and more reliable solutions At Korenix there is no need to compromise Korenix takes care of everything for you Fusion of Positive Outcomes You can end your search here Korenix is your one stop supply center for industrial communications and networking products Korenix was established by a group of professionals with over 10 yea
49. e JetNet 4706 4706f provides HTTP Web Interface and Secure HTTPS Web Interface for web management Web Interface The Korenix web management page uses JavaScript This allows you to use a standard Web browser such as Microsoft Internet Explorer or Mozilla FireFox to configure the switch from anywhere while connected to the network Before you attempt to use the embedded web interface to manage switch operation verify that your JetNet 4706 4706f Industrial Ethernet Switch is properly installed on your network and that every PC on the network can access the switch via Web browser 1 Verify that your network interface card NIC is operational and that your operating system supports TCP IP protocol 2 Wire the DC power to the switch and connect your switch to your computer 3 Make sure that the switch default IP address is 192 168 10 1 4 Change your computer IP address to 192 168 10 2 or another IP address in the 192 168 10 x subnet Network Mask 255 255 255 0 5 Switch to DOS command mode and ping 192 168 10 1 to verify a normal response time 6 Launch a web browser Internet Explorer or Mozilla FireFox on your PC 7 Type http 192 168 10 1 or the IP address of the switch into the Web address window Press Enter 8 Key inthe username and password The default username and password are admin Eorenix Jethet4 706 Switch Manager Please enter user name and password Site 192 168 10 1 User Hame admin Password
50. e in the amount of time equal to the Max Age then JetNet 4706 4 706f will reconfigure itself as a root bridge Once two or more devices on the network are recognized as a root bridge the devices will renegotiate to set up a new spanning tree topology JetNet 4706 4706f Industrial Managed PoE Switch 47 korenix Hello Time 1 10 Enter a value from 1 to 10 seconds here This is a periodic timer that drives the switch to send out a BPDU Bridge Protocol Data Unit packet to check current STP status The root bridge of the spanning tree topology periodically sends out a hello message to other devices on the network to check if the topology is healthy The hello time is the amount of time the root has waited in between sending hello messages Forward Delay Time 4 30 Enter a value between 4 and 30 seconds This value is the time that a port waits before changing from Spanning Tree Protocol learning and listening states to forwarding state This is the amount of time JetNet 4706 4 706f will wait before checking to see if it should be changed to a different state Once you have completed your configuration click on Apply to apply your settings Note You must observe the following rules to configure Hello Time Forwarding Delay and Max Age parameters 2 x Forward Delay Time 1 sec gt Max Age Time gt 2 x Hello Time value 1 sec Port Configuration Select the port you want to configure you will be able
51. e port mode and Port State 48 korenix e RSTP Information 4 System E Basic Setting Gr CH Port Configuration Root Information Q EJ Power over Ethernet BrdgelD 2000 0012 zg TN PoE Control PoE Scheduling Root Priority Lah Ta PoE Status RootPot Es CJ Network Redundancy boat ban Cost 0 TN RSTP Information Hello Time t 10 2 Sec TN Rapid Super Ring Forward Delayt4 30 te coe A Ring Information G CI VLAN Port Information Por Based VLAN CF SNMP EA 200000000 128 Auto Edge Disabled E 2 200000000 128 Auto Edge Disabled K ial Monitor and Diag 3 200000000 128 Auto Edge Disabled DN Device Front Panel o 200000000 128 Auto Edge Disabled Save 6 200000 128 Auto Edge Forwarding Ta Logout 6 200000000 128 Auto Edge Disabled 4 5 3 Rapid Super Ring RSR The most common industrial network redundancy is to form a ring or loop Typically the managed switches are connected in a series and the last switch is connected back to the first one In such a connection you can use Korenix Super Ring and Rapid Super Ring technology Super Ring is Korenix s 17 generation ring redundancy technology released with JetNet 4000 4500 Rapid Super Ring RSR is Korenix s ON generation Ring redundancy technology This is patented and protected by Korenix and is used in countries all over the world The Rapid Super Ring has an enhanced Ring Master selection and shorter recovery time JetNet 4706 4
52. em s information save a configuration and enter the global configuration mode You can type configure terminal to enter the next mode or exit to leave To see a list of available command types JetNet 4706 config access list Add an access list entry administrator Administrator account setting arp Set a static ARP entry clock Configure time of day clock default Set a command to its defaults end End current mode and change to enable mode exit Exit current mode and down to previous mode hostname Set system s network name interface Select an interface to configure ip IP information list Print command list log Logging control mac Global MAC configuration subcommands mac address table mac address table no Negate a command or set its defaults ntp Configure NTP password Assign the terminal connection password qos Quality of Service QoS relay relay output type information rmon Remote monitoring router Enable a routing process smtp server SMTP server configuration korenix Global Configuration mode Type configure terminal in privileged EXEC mode You can then enter the global configuration mode In global configuration mode you can configure all the features that the system provides Type interface IFNAME VLAN to enter interface configuration mode and exit to leave or for command list Available commands for global configuration mode are shown below JetNet 4706 configure terminal JetNet 4706 config if auto negotiat
53. enix Once you have finished configuring the settings click on Apply to apply your configuration Note When enabling Local or Both modes you can monitor the system logs in Monitor and Diag Event Log page 4 11 4 SMTP Configuration The JetNet 4706 4706f includes an E mail Warning feature The switch will send occurrences to a remote E mail server The receiver can then receive an E mail notification by E mail to SMTP standards This section shown in the next image allows you to enable the E mail Alert and assign the SMTP Server IP Sender E mail and Receiver E mail If the SMTP server requests your authorization first here you can also set up the username and password for that Warning SMTP Configuration E mail Alert Disable v SMTP Configuration C Authentication D escripti JetNet 4706 4706f Industrial Managed PoE Switch t korenix Rept E mail Address 1 The first email address to receive email alert from JetNet Max 40 characters Rept E mail Address 2 The second email address to receive email alert from JetNet Max 40 characters Rcpt E mail Address 3 The third email address to receive email alert from wendeg JetNet Max 40 characters Rcpt E mail Address A The fourth email address to receive email alert from JetNet Max 40 characters Once you have finished configuring the settings click on Apply to apply your configuration 4 11 5 CLI Commands Command Lines for Warnin
54. enix Port Statistics tal 100BASE Down Enable 0 Kg i 3 100BASE Down Enable 0 0 1TOOBASE Down Enable 0 0 l d 100BASE Down Enable 0 Ss 0 100BASE Down Enable 0 ge 0 5 1 00BASE TA Lp Enable 212 230 Clear All Bad Collision Mode Port Statistics OS 1 100BASE Dow Enable 0 0 100BASE Down Enable 5 0 5 0 E 100BASE Down Enable 0 0 4 100BASE Down Enable 0 DU 100BASE Down Enable 0 0 1 00BASE Tx Up Enable 0 0 Clear all Good Mode 4 12 3 Event Log In section 4 10 3 we introduced the System Log feature When System Log Local mode is selected JetNet 4706 4706f will record past events in the local log table This page shows the log table The entries include the index and data time and content of the occurrences Click on Clear to delete the entries Click on Reload to refresh the table System Event Logs 1 Jani 05 00 16 Event Link 1 Up A Jan 1 05 00 11 Event Link 1 Up 3 Jan 1 05 00 11 Event Link 1 Down 4 Jan 1 05 00 09 Event Link 2 Up 5 Jan 05 00 09 Event Link 2 Down Bi Jan 1 05 00 07 Event Link 1 Down cmar g et JetNet 4706 4706f Industrial Managed PoE Switch 83 korenix 4 12 4 Ping Utility Ping Utility This page provides Ping Utility for users to ping remote devices and to check whether the device is alive or not Type the target IP TargetiP_ 192 168 10 200 Ping address of the target d
55. es auto negotiation state of a given port description Interface specific description duplex Specifies the duplex mode of operation for a port end End current mode and change to enable mode exit Exit current mode and down to previous mode flowcontrol Sets the flow control value for an interface list Print command list loopback Specifies the loopback mode of operation for a port mac MAC interface commands mdix Enables mdix state of a given port no Negate a command or set its defaults poe Configure power over ethernet qos Quality of Service QoS quit Exit current mode and down to previous mode rate limit Rate limit configuration shutdown Shutdown the selected interface Spanning tree the spanning tree protocol speed Specifies the speed of a Fast Ethernet port or a Gigabit Ethernet port switchport Set switching mode characteristics JetNet 4706 config if rate limit Rate limit configuration shutdown Shutdown the selected interface spannina tree spannina tree protocol VLAN Interface Configuration Type interface VLAN VLAN ID in global configuration mode You can then enter the VLAN interface configuration mode In this mode you can configure the settings for a specific VLAN The VLAN interface name for VLAN 1 is VLAN 1 VLAN 2 is VLAN 2 You can type exit to leave or for a list of available commands Available commands for the VLAN interface configuration mode appear below Switch config interface vlan 1 Switch config if descr
56. ess table Table All types UNICAST MAC ADDRESS Destination Address Address Type Vlan Destination Port 000f b079 ca3b Dynamic 0012 7701 0386 Dynamic 0012 7710 0101 Static 0012 7710 0102 Static 0012 77ff 0100 Management MULTICAST MAC ADDRESS an Mac Address COS Status Ports 1 0100 5e40 0800 1 0100 5e7f fffa U fa4 fa6 Show MAC Address etNet 4706 show mac address table dy 84 korenix Table Dynamic Learnt Destination Address Address Type MAC addresses Show MAC Address Table Multicast MAC addresses Show MAC Address Table Static MAC addresses Show Aging timeout time Port Statistics Port Statistics Bad Collision Mode Good Mode Event Log Display Vlan Destination Port 000f b079 cb93 Dynamic etNet 4706 show mac address table multicast etNet 4706 Mana show mac address table multicast COS Status Ports etNet 4706 show mac address table static Destination Address Address Type Vian Destination Port 0012 7710 0101 Static 0012 7710 0102 Static etNet 4706 show mac address table aging time he mac address table aging time is 304 sec etNet 4706 show rmon statistics fa4 select interface RMON statistics counter mode is RxGood and TxGood mode Interface fastethernet1 is enable connected which has Inbound RxGood 1292 Outbound TxGood 1978 etNet 4706 config rmon statistics counter mode error collisions Set RMON statistics counter mode to RxError and TxCol
57. evice into Target IP Start Click on Start to start the ping You will be able to see the results in the Result field Result PING 192 168 10 200 192 168 10 200 56 data bytes 64 bytes from 192 168 10 200 icmp_seg 0 tt 128 time 0 0 ms 64 bytes from 192 168 10 200 icmp_seg 1 tt 128 time 0 0 ms 64 bytes from 192 168 10 200 icmp_seg 2 tt 128 time 0 0 ms 64 bytes from 192 168 10 200 icmp_seg 3 ttl 128 time 0 0 ms 64 bytes from 192 168 10 200 icmp_seq 4 ttl 128 time 0 0 ms 192 168 10 200 ping statistics 5 packets transmitted 5 packets received 0 packetloss round trip min ayg max 0 0 0 0 0 0 ms 4 12 5 CLI Commands for Monitoring and Diagnostic Command Lines for Monitoring and Diagnostic configuration Feature Command Line MAC Address Table Ageing Time etNet 4706 config mac address table aging time 350 mac address table aging time set ok Note 350 is the new ageing timeout value Add Static Unicast MAC JetNet 4706 config mac address table static address 0012 7701 0101 vlan 1 interface fastethernet1 mac address table ucast static set ok Note rule mac address table static MAC_address VLAN VID interface interface_name Add Multicast MAC etNet 4706 config mac address table multicast address 0100 5e01 0101 vlan 1 interface fa1 6 Adds an entry in the multicast table ok Note rule mac address table multicast MAC_address VLAN VID interface_list interface_name range Show MAC Address etNet 4706 show mac addr
58. ew settings will be updated after a power cycle You can use show startup config to view it in the CLI The Backup command can only backup such configuration files to your PC or TFTP server Technical Tip Default Configuration File The switch provides the default configuration file in the system You can use the Reset button Reload command to reset the system Running Configuration File The switch s CLI allows you to view the latest settings running on the system The information shown here are the settings you set up but have not saved to flash The settings not yet saved to flash will not work after a power cycle You can use show running config to view it in the CLI The following figure is the Main UI for Backup amp Restore Backup amp Restore Backup Configuration Localrile Le Backup FileName D TFTPibackup conf JC Restore Configuration TFTP Server 1 92 168 10 100 backup conf Click on the Folder icon to select the target file you want to backup restore Note The folders of the path to the target file do not allow you to input space key JetNet 4706 4706f Industrial Managed PoE Switch 30 korenix The following figure is the Web UI for Backup Restore Configuration TFTP Server mode Backup Configuration TFTP server fi 9g2 168 0 100 backup conf Type in the IP address of TFTP Server IP Then click on Backup Restore Note The file is named Quagga conf This file name can
59. g configuration Relay Output Relay Output etNet 4706 config relay 1 dry dry output ping ping failure port port link failure power power failure ring super ring failure Dry Output etNet 4706 config relay 1 dry lt 0 4294967295 gt turn on period in second etNet 4706 config relay 1 dry 5 lt 0 4294967295 gt turn off period in second etNet 4706 config relay 1 dry 55 Ping Failure etNet 4706 config relay 1 ping 192 168 10 33 lt CI gt reset reset a device etNet 4706 config relay 1 ping 192 168 10 33 reset lt 1 65535 gt reset time etNet 4706 config relay 1 ping 192 168 10 33 reset 60 lt 0 65535 gt hold time to retry etNet 4706 config relay 1 ping 192 168 10 33 reset 60 60 Port Link Failure etNet 4706 config relay 1 port PORTLIST port list etNet 4706 config relay 1 port fa1 5 Power Failure etNet 4706 config relay 1 power lt 1 2 gt power id etNet 4706 config relay 1 power 1 etNet 4706 config relay 1 power 2 etNet 4706 config relay 1 ring Disable Relay etNet 4706 config no relay lt 1 2 gt relay id 78 korenix SG etNet 4706 config no relay 1 Relay_ID 1 or 2 lt Cr gt Display etNet 4706 show relay 1 Relay Output Type Port Link Port 1 2 3 4 etNet 4706 show relay 2 Relay Output Type Super Ring Event Selection Event Selection etNet 4706 config warning event coldstart Switch cold start event warmstart Switch warm start event linkdown Switch link down event l
60. gn 4 community strings Type in each community string and select its privilege Then press Apply Note When you first install the device onto your network we highly recommend that you change the community string Because most SNMP management applications use Public od FO 67 korenix 4 9 2 and Private as their default community name this may cause a leak in network security SNMP v3 Profile SNMP v3 can provide more security functions when the user performs remote management through SNMP protocol It delivers SNMP information to the administrator with user authentication all of data between JetNet 4706 4706f and the administrator are encrypted to ensure secure communication SNMP V3 Profile SNMP Y3 Authentication T SHA Security Level Here the user can select the following levels of security None User Authentication and Authentication with privacy Authentication Protocol Here the user can select either MD5 Message Digest algorithm 5 or SHA Secure Hash Algorithm MD5 is a widely used cryptographic hash function with a 128 bit hash value SHA Secure Hash Algorithm hash functions refer to five Federal Information Processing Standard approved algorithms for computing a condensed digital representation JetNet 4706 4 706f provides 2 user authentication protocols in MD5 and SHA You will need to configure SNMP v3 parameters for your SNMP tool with the same authentication method Authentication Password Here t
61. he user enters the SNMP v3 user authentication password DES Encryption Password Here the user enters the password for SNMP v3 user DES Encryption JetNet 4706 4706f Industrial Managed PoE Switch 68 korenix 4 9 3 SNMP Traps SNMP Trap is a notification feature defined by SNMP protocol All SNMP management applications can understand this type of trap information You will not need to install new applications to read the notification information This page allows users to Enable SNMP Trap configure the SNMP Trap server IP Community name and trap Version V1 or V2 After the configuration you will be able to see the changes made to the SNMP pre defined standard traps and the Korenix pre defined traps The pre defined traps can be found in Korenix s private MIB SNMP Trap SNMP Trap Enable r Apply SNMP Trap Server Trap Server Profile 192 166 710 200 public WAE 192 166 710 200 public VI ec Reload 4 9 4 CLI Commands for SNMP Command Lines for SNMP configuration SNMP Community Read Only Community JetNet 4706 config snmp server community public ro JetNet 4706 4706f Industrial Managed PoE Switch 69 korenix Communi string add ok Read Write Community JetNet 4706 config snmp server community private rw ommunity string add ok SNMP Trap Enable Trap etNet 4706 config snmp server enable trap et SNMP trap enable ok SNMP Trap Server IP etNet 4706 config snmp server host 192 168
62. ill see the cipher information in the popup screen Press Yes to accept the Security Alert Ful IX Securty Alert The server s host key is not cached in the registry You have no guarantee that the server is the computer you think it is The server s raat key fingerprint 1s ssh rsa 1024 SSccfe 6T 1263 f f4 3060 8500 be Al 29 If you tust this host hit Yes to add the key to PuTTY cache and cary on connecting Tf you want to Cart on connecting just once without adding the key to the cache hit No Tf you do not tot this host hit Cancel to abandon the connector JetNet 4706 4 706f Industrial Managed PoE Switch 14 korenix 3 After a few seconds the SSH connection to JetNet 4706 4706f will open ce 192 168 10 1 PuTTY 4 Type in the login name and password The default login name and password are admin 5 All the commands you see in SSH are the same as the CLI commands you see via RS232 console The next chapter will introduce in detail how to use the command line to configure the switch 15 korenix 4 Feature Configuration This chapter explains how to configure the JetNet 4706 4706f software and its features The following topics are covered in this chapter 4 1 Command Line Interface CLI Introduction 4 2 Basic Settings 4 3 Port Configuration 4 4 Power over Ethernet 4 5 Network Redundancy 4 6 VLAN 4 7 Traffic Prioritization 4 8 Multicast Filtering 4 9 SNMP 4 10 Security 4 1
63. inkup Switch link up event all Switch all event authentication Authentication failure event fault relay Switch fault relay event power Switch power failure event super ring Switch super ring topology change event time sync Switch time synchronize failure event etNet 4706 config warning event coldstart et cold start event enable ok Ex Link Up event etNet 4706 config warning event linkup IFNAME Interface name ex fastethernet1 or gi8 etNet 4706 config warning event linkup fa5 Set fad link up event enable ok Display etNet 4706 show warning event arning Event Cold Start Enabled Warm Start Disabled Authentication Failure Disabled Link Down fa4 5 Link Up fa4 5 Power Failure Super Ring Topology Change Disabled Fault Relay Disabled Local Mode etNet 4706 config log syslog local Both etNet 4706 config log syslog local etNet 4706 config log syslog remote 192 168 10 33 SMTP Configuration SMTP Enable etNet 4706 config smtp server enable email alert MTP Email Alert set enable ok Sender mail etNet 4706 config smtp server server 192 168 10 100 ACCOUNT SMTP server mail account ex admin korenix com etNet 4706 config smtp server server 192 168 10 100 admin korenix com MTP Email Alert set Server 192 168 10 100 Account admin korenix com ok etNet 4706 config smtp server receipt 1 korecare korenix com MTP Email Alert set receipt 1 korecare korenix com ok etNet 4706 config smtp server authen
64. ion Enables auto negotiation state of a given port description Interface specific description duplex Specifies the duplex mode of operation for a port end End current mode and change to enable mode exit Exit current mode and down to previous mode flowcontrol Sets the flow control value for an interface list Print command list loopback Specifies the loopback mode of operation for a port mac MAC interface commands mdix Enables mdix state of a given port no Negate a command or set its defaults poe Configure power over ethernet qos Quality of Service QoS quit Exit current mode and down to previous mode rate limit Rate limit configuration shutdown Shutdown the selected interface Spanning tree The spanning tree protocol speed Specifies the speed of a Fast Ethernet port or a Gigabit Ethernet port switchport Set switching mode characteristics Port Interface Configuration Type interface IFNAME in global configuration mode You can then enter interface configuration mode In this mode you can configure port settings The port interface name for fast Ethernet port 1 is fa1 fast Ethernet 6 is fa6 You can type the interface name accordingly when you want to enter a specific interface configuration mode You can type exit to leave or for a list of available commands 18 korenix Below are the available commands for port interface configuration mode JetNet 4706 config interface fa2 JetNet 4706 config if auto negotiation Enabl
65. iption Interface specific description end End current mode and change to enable mode exit Exit current mode and down to previous mode ip Interface Internet Protocol config commands list Print command list no Negate a command or set its defaults quit Exit current mode and down to previous mode shutdown Shutdown the selected interface 19 korenix The following is a summary of command modes User EXEC Privileged EXEC Global configuration Port Interface configuration This is the first level of access Eer Type login to login Switch gt Users can ping telnet remote Exit Type exit to logout device and show basic Next mode Type enable to information enter privileged EXEC mode In this mode the system allows Enter Type enable in User Switch you to view current configuration EXEC mode reset to default reload the Exec Type disable to exit to switch show the system s user EXEC mode information save a configuration Type exit to logout and enter global configuration Next Mode Type configure mode terminal to enter global configuration command In global configuration mode you Enter Type configure Switch config can configure all the features that terminal in privileged EXEC the system provides mode Exit Type exit or end or press Ctrl Z to exit Next mode Type interface IFNAME VLAN VID to enter interface configuration mode In this mode you can configure Enter Type interface IFNAME Switch config if
66. korenix Korenix JetNet 4706 4706f Industrial Managed PoE Switch User Manual Version 1 02 Sep 2007 korenix www korenix com JetNet 4706 4706f Industrial Managed PoE Switch korenix Korenix JetNet 4706 4706f Industrial Managed PoE Switch User Manual Copyright Notice Copyright 2007 Korenix Technology Co Ltd All rights reserved Reproduction in any form or by any means without permission is prohibited korenix Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment Idee eh d DEE 1 Wek EEN 1 L2 Proget Feats eneu ae 2 Isa Package Check EE 2 Hardware Installation cccccsseses
67. ktop IP 31 grade aluminum metal case 45 5 mm H x 185 3 mm W x 136 mm D without DIN 0 72 kg with package 0 65 kg without package 89 korenix Environmental Operating Temperature Operating Humidity Storage Temperature Storage Humidity Regulatory Approvals Safety EMI EMS Shock Vibration Free Fall Warranty JetNet 4706 20 C 60 C JetNet 4706f 10 C 60 C 5 90 non condensing 40 80 C 5 90 non condensing CE EN60950 FCC Class B CE EN55022 2003 class B CE EN61000 3 2 2001 Harmonic Test CE EN61000 3 3 1995 Flicker test EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS IEC60068 2 27 IEC60068 2 6 IEC60068 2 32 5 Years 5 2 Pin Assignment for RS 232 Console Cable The total length of the cable is 150cm 58 5 excluding RJ45 and DB9Y DB9 is Female ee 5 3 Korenix Private MIB Korenix provides many standard MIBs for users to configure or monitor the switch s configuration through SNMP But since some commands can not be found in standard MIB Korenix provides Private MIB to meet the needs Compile the private MIB file with your SNMP tool You will then be able to use it Private MIB can be found in the product CD or downloaded from the Korenix Web site www korenix com 90 korenix The private MIB tree is the same as the web tree This is easier to understand and use If you are not familiar with the standard MIB dire
68. l NTP to synchronize time from the internet Port Based VLAN with Tagged Un Tagged and not modify functions Supports IGMP Snooping mode and IGMP v1 v2 Query modes Supports Rapid Super Ring function for network redundancy with sms network recovery time To inter operate with other higher level switches it provided Dual Homing II technology compliant with RSTP protocol JetNet 4706 4706f is also compliant with the IEEE 802 1d 2004 edition of RSTP and STP 1 Dry Relay Contact output for port link down PoE and System power events Supports 1A 24V current ability 88 korenix Firmware upgrade PoE Port Control Power Limit Control PoE Scheduling Control LPLD function Interface Number of Ports Connectors PoE Technology Cable Rest Button Diagnostic LED Power Requirements System Power Power Consumption Mechanical Installation Case Dimension Weight TFTP and HTTP firmware upgrade Supports user configuration of PoE enable disable The control mode supports IEEE 802 3af standards Manual and Ultra mode for 30W Hi power The maximum deliver power on each PoE port is 12 915W DC 24V input 30W en DC55V input Each PoE port can activate and power on with different schedules H supports weekly and hourly scheduling The Link Partner Line Detect function LPLD is available on the PoE port only and provides a period of automatic detect function for PD Status If the PD is fails or is not responsive to the
69. l maintain the IP address so that you can still connect to the switch via the network JetNet 4706 4706f Industrial Managed PoE Switch 33 korenix 4 2 9 System Reboot System Reboot allows you to reboot the device Some of the feature changes require you to reboot the system Click on Reboot to reboot your device Note Remember to click on the Save button to save your settings Otherwise the settings you made will be gone once the switch is powered off Below is the Main screen for Reboot CJ JetNet4 706 Reboot TN System CJ Basic Setting G Switch Setting Please click Reboot button to restart switch device IN Admin Password 4 IP Configuration Reboot 4 Time Setting O DHCP Server 4 Backup and Restore 4 Firmware Upgrade IN Factory Default IN System Reboot Below is the popup alert screen to request confirmation for the Switch Reboot Click on Yes to reboot the switch Confirm Dialog Success Message i Switch rebooting Auto relogin after 30 seconds OK 4 2 10 CLI Commands for Basic Settings Command Line System Name Switch config hostname WORD Network name of this system JetNet 4706 4 706f Industrial Managed PoE Switch 34 korenix LS System Contact Display Admin Password User Name and Password Display IP Configuration IP Address Mask 192 168 10 8 255 255 255 0 Remove Gateway Time Setting NTP Server Switch config hostname JetNet 4706 JetNet 4706 co
70. lisions mode etNet 4706 config rmon statistics counter mode good Set RMON statistics counter mode to RxGood and TxGood 1 02 50 47 snmpd 101 Event Link 4 Down 1 02 50 50 snmpd 101 Event Link 5 Up 1 02 50 51 snmpd 101 Event Link 5 Down 1 02 50 53 snmpd 101 Event Link 4 Up etNet 4706 ping 192 168 10 33 PING 192 168 10 33 192 168 10 33 56 data bytes 64 bytes from 192 168 10 33 icmp_seq 0 ttl 128 time 0 0 ms 64 bytes from 192 168 10 33 icmp_seq 1 ttl 128 time 0 0 ms 64 bytes from 192 168 10 33 icmp_seq 2 ttl 128 time 0 0 ms 64 bytes from 192 168 10 33 icmp_seq 3 ttl 128 time 0 0 ms 64 bytes from 192 168 10 33 icmp_seq 4 ttl 128 time 0 0 ms 192 168 10 33 ping statistics packets transmitted 5 packets received 0 packet loss round trip min avg max 0 0 0 0 0 0 ms 85 korenix 4 13 Device Front Panel Device Front Panel provides Web type LED panel which indicates status of power PoE powering and link status of Ethernet ee Device Front Panel amp system 1 Basic Setting o Por Configuration o c Power over Ethernet dch korenix EJ Network Redundancy GE eg VLAN BACHE TEST CH Traffic Prioritization Industrial Managed PoE Switch oC Multicast Filtering SNMP oC Security vw E Warning e CT Monitor and Diag Device Front Panel 4 14 Save to Flash Save Configuration allows you to save any configuration you just made to the Flash Powering off the switch without clicking on
71. me Command Mode Enable mode Description Display the PoE status of interface Examples JetNet 4706 gt enable JetNet 4706 show poe status fa1 Interface fastethernet1 POE Status Secheduler Admin status Enable Detection status Searching Port Type POE Port 1 Classification Case POE Usage Power 0 0 Watts Voltage 0 0 V Current 0 0 mA POE Limitation Limitation Mode Ultra Max Power 25 0 Watts POE Counter MPS Absent Counter 0 Invalid Signature Counter 0 Denied Counter 0 Overload Counter 0 Short Counter 0 Parameters Command Mode Enable mode Description Display the status of pd status detection JetNet 4706 4706f Industrial Managed PoE Switch 43 korenix Examples JetNet 4706 show poe pd detect PD Status Detection Status Enabled Host 1 Target IP 192 168 10 100 Cycle Time 10 Host 2 Target IP 192 168 10 200 Cycle Time 20 Host 3 Target IP 192 168 10 15 Cycle Time 30 Host 4 Target IP 192 168 10 20 Cycle Time 40 show poe sch IFNAME interface name Parameters Command Mode Enable mode Description Display the status of schedule of interface Examples JetNet 4706 show poe schedule fat Interface fastethernett POE Schedule Status Disable Weekly Schedule Sunday 0 1 2 3 4 5 6 7 8 19 20 21 22 23 Monday 0 1 2 3 4 5 6 7 8 19 20 21 22 23 Tuesday 0 1 2 3 4 5 6 7 8 19 20 21 22 23 Wednesday 0 1 2 3 4 5 6 7 8 19 20 21 22 23 Thursday 0 1 2
72. n Ctrl Z Exits configuration mode An alert message appears when multiple users try to configure the switch If the administrator is in configuration mode then Web users will not be able to change the settings JetNet 4706 4706f only allows one administrator at a time to configure the switch Eror Messaze korenix pe 4 2 Basic Settings This section provides you with instructions on how to configure switch information set the IP address and configure the username and password of the system It also allows you to upgrade the firmware backup and restore a configuration reload the system to factory default and reboot the system The following is included in this section 4 2 1 Switch Setting 4 2 2 Admin Password 4 2 3 IP Configuration 4 2 4 Time Setting 4 2 5 Backup and Restore 4 2 6 Firmware Upgrade 4 2 7 Factory Default 4 2 8 System Reboot 4 2 1 Switch Setting You can assign a System name Location Contact and view the system information The following figure is the Web UI for Switch Setting korenix JETA Your Industrial Computing amp Networking Partner CJ JetNet4 Op GE Switch Setting CJ Basic Setting D switch Setting A Admin Password A IP Configuration A Time setting CT DHCP Server A Backup and Restore A Firmware Upgrade A Factory Default A System Reboot amp C Port Configuration Apply G C Power over Ethernet Gr EJ Network Redundancy CH VLAN A Traffic Prioritization
73. nfig JetNet 4706 config snmp server location Taipei JetNet 4706 config snmp server contact korecare korenix com JetNet 4706 show snmp server name JetNet 4706 JetNet 4706 show snmp server location Taipei JetNet 4706 show snmp server contact korecare korenix com JetNet 4706 gt show version 0 31 20061218 Switch show hardware mac MAC Address 00 12 77 FF 01 B0 JetNet 4706 config administrator NAME Administrator account name JetNet 4706 config administrator admin Command incomplete JetNet 4706 config administrator orwell PASSWORD Administrator account password JetNet 4706 config administrator orwell orwell Change administrator account orwell and password orwell SUCCESS JetNet 4706 show administrator Administrator account information name orwell password orwell JetNet 4706 config int vlan 1 JetNet 4706 config if ip address 192 168 10 8 24 JetNet 4706 config ip route 0 0 0 0 0 192 168 10 254 24 JetNet 4706 config no ip route 0 0 0 0 0 192 168 10 254 24 Display JetNet 4706 show running config interface vlan1 ip address 192 168 10 8 24 no shutdown ip route 0 0 0 0 0 192 168 10 254 24 JetNet 4706 config ntp peer 192 168 10 100 JetNet 4706 config clock timezone 26 SunJan 1 04 13 24 2006 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London 35 korenix Note By typing clock timezone you can see the timezone list Then choose the number of the
74. not be modified Before you attempt to restore the configuration file please make sure it is named Quagga conf 4 2 7 Firmware Upgrade In this section you can update the switch with the latest firmware Korenix provides the latest firmware on their Web site www korenix com New firmware may include new features bug fixes or other software changes The Web site also provides release notes for the update as well We suggest you use the latest firmware before installing the switch Note The system will automatically rebooted after you finish upgrading the new firmware Please inform all attached users before doing this The following figure is the Web Main UI for Firmware Upgrade Firmware Upgrade System Firmware version v0 0 9 System Firmware Date 20070514 Firmware Upgrade Local File Firmware File Mame fie etNetd 06 0 0 6 bin Cl Mote When firmware Upgrade is finished the switch will restart automatically Upgrade There are 2 modes for users to backup restore the configuration file Local File mode and TFTP Server mode Local File mode In this mode the switch acts as the file server Users can browse the target folder and then type in the file name to backup the configuration Users can also browse the target folder and select the existing configuration file to restore the configuration back to the switch This mode is only provided by Web UI CLI is not supported TFTP Server mode In this mode the swi
75. oS Only The system will provide a default CoS Queue table that you can refer to for the next command After configuring press Apply to enable the settings 4 7 2 CoS Queue Mapping This area is where the user can set CoS values to the Physical Queue mapping table Since the switch fabric of JetNet 4706 4706f supports 4 physical queues Lowest Low Middle and High users should assign CoS value to the level of the physical queue With the JetNet 4706 4706f users can easily assign the mapping table or follow suggestions from the 802 1p standard Korenix uses 802 p standards for its default values You will find that the CoS values 1 and 2 are mapped to physical Queue 0 lowest queue CoS values 0 and 3 are mapped to physical Queue 1 low normal physical queue CoS values 4 and 5 are mapped to physical Queue 2 middle physical queue and CoS values 6 and 7 are mapped to physical Queue 3 highest physical queue CoS Queue Mapping CoS Queue Mapping F EE A F F T F F Mote Queue 3 is the highest priol Apply i After configuring press Apply to enable the settings 4 7 3 DSCP Queue Mapping Traffic Prioritization This is where users can change DSCP Queue Mapping DSCP values to a Physical Queue mapping table Since the switch mse cere Mies Pa ser iten ere fabric of the JetNet 4706 4706f en HRS ima BE 7 t i
76. on of a remote device powered by JetNet 4706 4706f If the remote system crashes or is unstable JetNet 4706 4706f will perform a system reboot by turning off and on again to trigger the remote device The following figure shows the Web configure interface for Power over Ethernet PD Status Detection PD Status Detection Enable IF Address le vole Time eis A Cycle Time s 1 ae T 182168 10 200 20 192 168 10 15 ER You can enable disable PD Status Detection function and type in the IP address that you want to detect The Cycle Time is the gap per detection After configuring please click Apply to enable and perform the functions 4 4 2 PoE Scheduling The PoE Scheduling control is a powerful function to help you save power and money You need to configure PoE Scheduling and select a target port manually to enable this function Power over Ethernet Schedule PoE Schedule on is Enabled JetNet 4706 4706f Industrial Managed PoE Switch 42 korenix 4 4 3 PoE Status The PoE Status page shows the operating status of each PoE Port The information includes Detection status current PD class Power Consumption and delivered Voltage and Current Power over Ethernet Status UU UU 0 0 Disable Disabled MA 2 Enable Delivering Power Class3 07 45 5 16 1 ES Enable Searching NI UU UU 0 0 4 Schedule Disabled Vu 0 0 0 0 0 0 4 4 4 Command Line for PoE control Parameters IFNAME interface na
77. or to the serial communication port RS 232 of your PC 2 Open Terminal tool and set up serial settings to 9600 N 8 1 Baud Rate 9600 Parity Check None Data Bit 8 Stop Bit 1 Then you can access the CLI interface through the console cable Note If you lose the cable please contact your sales representative to purchase a new one The pin assignment spec is listed in the Appendix korenix 2 8 DIN Rail Mounting Installation There are 2 DIN Rail Clips included Each set of DIN Rail clips include 4 screws and 2 clips If the DIN Rail set is missing please contact a Korenix distributor for help E Use the screws provided to attach the DIN Rail clip to the wall mount plate of the JetNet 4706 4706f 2 9 Wall Mount Installation Follow the steps below to install the JetNet 4706 4 706f wall mount plate Use the hook holes located at the corners of the wall mount plate to hang JetNet 4706 4706f onto a wall ee LSC ien DOE 139 Wall mount JetNet 4706 4706f Industrial Managed PoE Switch 9 korenix 3 Preparation for Management 3 1 The Korenix JetNet 4706 4706f Industrial Managed PoE Switch provides both in band and out band configurations With out band management you can configure the switch via RS232 console cable if you do not want to include your admin PC as part of your network Also in case you lose network connection you will still be able to configure the switch via RS232 console cable
78. ort of JetNet 4706 4706f supports Tag modify function It includes Untagged Tagged or Un modify modes The packets egress from this port are modified according to the selected rule JetNet 4706 4 706f Industrial Managed PoE Switch 56 korenix The following figure is the Web user interface for a Port Based VLAN Port Based VLAN Management VLAN ID i Apply Port Based VLAN leen WICH DN IN Si B E ae 8 K msb E o_o Apply 4 6 3 CLI Commands of the VLAN Command Lines of the VLAN port configuration VLAN configuration and VLAN table Untaggqed a sfe IO e e Iw SE KI RI SI El KI 5 E KI H display Displays the current port based show vlan vlan configuration for each port ex which include the default PVID ManagedSwitch sh vlan the ports for forwarding and the Port based vlan mode egress mode of the port Port PVID EgressMode Egress Ports fa1 1 Tagged fa2 3 fa2 1 Untagged fa3 4 fa3 1 Untagged fa1 2 fa4 6 fa4 1 Untagged fa1 3 fa5 6 fa5 3 Untagged fa1 4 fa6 fa6 1 Untagged fai 5 ManagedSwitch JetNet 4706 4706f Industrial Managed PoE Switch 57 korenix The ports where the frame comes in to this port are allowed to forward to Assign default PVID for this port Specify when a frame that is egressing from this port should be tagged untagged or unmodified switchport port based vlan egress ports IFLIST ex port 1 can forward packet to port 2
79. ou can enable IGMP Snooping and IGMP Query functions here You will see the information of the IGMP Snooping function in this section including different multicast member ports and IP multicast addresses that range from 224 0 0 0 to 239 255 255 255 The following commands are included in this group 4 7 1 IGMP Snooping 4 7 2 IGMP Query 63 korenix 4 8 1 IGMP Snooping This page is to enable disable the IGMP Snooping feature and view the IGMP Snooping table from dynamic learnt IGMP Snooping you can select Enable or Disable here CA JetNets7o6 IGMP Snooping B System o C Basic Setting o CT Fort Configuration IGMP Snooping ji E Ge over Ethernet etwork Redundancy o A VLAN o CI Traffic Prioritization IGMP Snooping Table o CC Multicast Filtering amp IMP Snooping Py IGMP Query 239 266 256 250 SVL DC e CC SNMP o CT Security o CT warning o CH Monitor and Diag Device Front Panel B Dave e B Logout IGMP Snooping Table In the table you can see the multicast group IP address and the member ports of the multicast group The JetNet 4706 4706f supports 256 multicast groups Click Reload to refresh the table JetNet 4706 4706f Industrial Managed PoE Switch 64 korenix 4 8 2 IGMP Query CJ JetMet47 06 D system IGMP Query o C Basic Setting gt C Port Configuration IGMP Query on the Management VLAN o C Power over Ethernet o CJ Network Redundancy version 2 e o 4 VLAN S O S E Traffic Prioriti
80. ow control rate limit control and port aggregation settings It also allows you to view port status and aggregation information The following commands are covered in this section 4 3 1 Port Control 4 3 2 Port Status 4 3 3 Rate Control Port Control Port Control commands allow you to enable disable port state or configure port auto negotiation speed duplex and flow control LC SE Port Configuration ystem CJ Basic Setting TN Switch Setting A Admin Password Enable e AutoNegatiation Disable 4 IP Configuration 2 Enable w AutoNeqatiation e Disable k D Time Seting La Enable e AutoNegatiation h Disable h GC DHCP Server E Backup and Restore a Enable e AutoNegatiation T Disable h A Firmware Upgrade el Enable e AutoNegatiation T Disable TN Factory Defaut el Enable AutoNegatiation Disable i System Reboot o CT Port Configuration Apphy Drog Control TN Port Status Ci Rate Contral ie Gi an ee re OT pa E Ree ed LEE E E State peediDuplex low Contro Select the port you want to configure and make changes to the port State column Enable or disable the state of this port Once you disable the port it stops te linking and forwarding traffic The default setting when you receive the device is Enable which means all the ports are working Speed Duplex column Configure the port speed and duplex mode of this port Below
81. peration and will close under faulty conditions faulty conditions can include power failure Ethernet port link break or other predefined events configurable in the JetNet 4706 4 706f user interface Wiring the digital output is exactly the same as wiring power inputs introduced in section 2 2 see 2 2 Wiring Power Inputs 2 4 Wiring Earth Ground To ensure the system will not be damaged by noise or electric shock we suggest making a direct connection between the JetNet 4706 4706f and earth ground to avoid system damage 1 On the right side of the JetNet 4706 4706f there is one earth ground screw 2 Loosen the earth ground screw with a screwdriver 3 Tighten the screw after the earth ground wire is connected 2 5 Wiring 10 100Base TX Fast Ethernet Ports The JetNet 4706 4706f is equipped with 4 Port Power over Ethernet PoE injectors with 30w forwarding capability in ports 1 4 The 10 100Base TX Fast Ethernet ports support 10Base T and 100Base TX full or half duplex modes All the 10 100Base TX Fast Ethernet ports will auto detect signals from connected devices in order to decide the correct link speed and duplex mode Auto MDI MDIX allows users to connect another switch hub or workstation without changing Straight Through or Crossover Cables Note that Crossover Cables cross connect the transmitter lines to the receiverd lines at the opposite end Switch Router or PA Switch Swi teh 3 TD 3 RD 3 In 3 TDH 6 TD
82. pply Fault Relay Setting Ping Failure Dry Output Power Failure Link Failure Ping Failure Super Ring Failure Relay 1 Check the box Relay 1 then select the Event Type and its parameters i Event Type You will be given the following Apply options Dry Output Power Failure Link Failure Ping Failure and Super Ring Failure Each event type has its own parameters and are configuratble Each Relay can have one event type JetNet 4706 4706f Industrial Managed PoE Switch 72 korenix Event Type Dry Output On Period Sec Type in the amount of time you would like Relay Output to be on This can range from 0 4294967295 seconds Off Period Sec Type in the amount of time you would like Relay Output to be off This can range from 0 4294967295 seconds When the amount of time is reached the system will turn the Relay Output on or off 0 Event Type Power Failure Power ID Select either Power 1 or Power 2 When power is shut down the system will short Relay Out and light the DO LED Power Failure Power 1 Fault Relay Setting Event Type Link Failure Link Select the port ID you would like to monitor How to configure Check the box of the Ethernet ports you wish to monitor You may select multiple ports When the selected ports are unlinked the system will short Relay Output and light the DO LED Apply HM UO mM Oyo d Event Type Ping Failure IP Address
83. queuing scheme scheme This is also known as WRR Weight ce Round Robin JetNet will follow a 8 4 2 1 rate Us a strict priority scheme to process the packets in a queue from the highest priority to the lowest For example the system will simultaneously process 8 packets with the highest priority in the queue 4 packets with middle priority 2 packets with low priority and 1 packet with the lowest priority Port Setting Use a strict priority scheme Packets with the highest priority in the queue will always be processed first Port Setting The Priority column is to indicate the default port priority value for untagged or priority tagged frames When JetNet 4706 4706f receives the frames JetNet 4706 4706f will assign the value to the priority You can enable 0 1 2 3 4 5 6 or 7 to the port The priority is directly mapping to queue id queue 3 is the highest priority queue Trust Mode This indicates Queue Mapping types for you to select CoS Only Port priority will only follow CoS Queue Mapping that you have assigned DSCP Only Port priority will only follow DSCP Queue Mapping that you have assigned CoS first Port priority will follow CoS Queue Mapping first and then DSCP Queue Mapping rule DSCP first Port priority will follow DSCP Queue Mapping first and then CoS Queue 59 korenix Mapping rule Port Based The port priority will follow the queue priority that you have assigned The default priority type is C
84. r TX amp Posie Vor a TeaPostve von RX8 Negatvepon i Seegen a 1 Sege o TeaPostive voor erausge ee rege el 1 1 emgeie Pin assignment of PSE Make sure the twisted pair cable is bound with the standard RJ 45 pin especially pins 4 5 7 and 8 If the RJ 45 is bound with the wrong pin number JetNet 4706 4 706f will not recognize the PD and will not forward DC power to the PD This is because the JetNet 4706 4706f switch follows the Alternative B mode The IEEE 802 3af indicates that the PD should support mode A and B but only receive power from either mode A or B korenix The following table shows the Ru 45 pin out for the PD 1 Postve voor Neoaive por O O 2 Postve voor Neoawe Voor o Nevatve vorPostve vot e __ _I Postve vor Neste Vpor e Festive vor Neste voon e neoane vor Postve vot O SS Nona voor Poste voor es Note voor Poste Voor Note 1 Before installing the Powered Device PD please ensure the PD pin assignment follows the IEEE 802 3af PD standards There are some IEEE 802 3af pre standard PDs that only accept mode A for power IEEE 802 3af indicates that the PD should be powered by either Mode A or B Note 2 For PoE High Power feeding purpose JetNet4706 JetNet4706f should be wall mounted on control panel to obtain great heat radiation 2 7 Wiring RS 232 Console Cable and pin assignment Korenix includes one RS 232 DB 9 to RJ 45 cable 1 Connect the DB 9 connect
85. renix 4 4 1 PoE Control You can pull down the PoE state column to enable disable ports or set it to scheduling control mode The Power Mode provides Standard mode for IEEE 802 3af PD Manual mode for user configuration of the power limit to IEEE 802 3af standard PD or Ultra mode for user configuration to perform at the 30w power limitation The following figure shows the Web UI interface for Power over Ethernet Control Power over Ethernet Control noer LIM tit a hae at cea ter GES EN PoE Mode Ower Mode Por 4 enabie sllga an 2 scnedue Standard 3 enable Manual se 4 Ere uma faao Apply You can type a value into the Power Limit column to set the limitation of power consumption lf JetNet 4706 4706f is set to Standard mode JetNet 4706 4706f will execute IEEE 802 3af power limiting rule by PD class The maximum value of Manual mode is 15 4w Ultra mode is 30w Note 1 For high power feeding JetNet 4706 4706f must powering with DC 55V to deliver maximum power Note 2 Ensure JetNet 4706 4706f mounted on well heat radiated panel and under 60 C environment during PoE port progress High Power forwarding High Power PoE Feeding will cause system temperature rised up DO NOT TOUCH DEVICE SURFACE DURING PoE PROGRESS HIGH POWER FEEDING korenix PD Status Detection JetNet 4706 4706f delivers a useful function PD Status Detection This provides automatic detecti
86. rs of experience in the arenas of industrial control data communications and industrial networking applications Korenix is geared towards fulfill your demands and expectations by providing a variety of products and services customized to your needs Korenix s industrial grade products also come with quality services and support Korenix stands by you all the way Core Strength Competitive Price and Quality With our work experience and in depth knowledge of industrial communications and networking Korenix is able to combine Asia s research and development capabilities with competitive production cost and quality support Global Sales Strategy Korenix s global sales strategy focuses on establishing and developing trustworthy relationships with distributors and channel partners and assisting OEM distributors in the promotion of their own brands Korenix supplies products that exceed local market standards of design quality sales marketing and customer services allowing Korenix and its distributors to design create and profit together Quality Services KoreCARE is Korenix s global service center where our professional staff is ready to solve your problems at any time All of Korenix s products have passed ISO 9000 EMI CE FCC UL certifications E mail KoreCARE at koreCARE korenix com 5 Year Warranty Each of Korenix s products are designed produced and tested to high industrial standards Korenix warrants that the product s
87. s fi 92 168 10 200 Add Excluded Address List 192 168 10 200 2 Remove Manual Binding JetNet 4706 4 706f provides a MAC address and IP address binding and removing function You can type in the specified IP and MAC address then click Add to add a new MAC amp IP address binding rule for a specified link partner like PLC or any device without DHCP client function To remove from the binding list just select the rule to remove and click Remove Manual Binding Remove JetNet 4706 4706f Industrial Managed PoE Switch 28 korenix DHCP Leased Entries JetNet 4706 4706f provides an assigned IP address list for user check It will show the MAC and IP address that was assigned by JetNet 4706 4706f Click the Reload button to refresh the listing korenix Your Industrial Computing amp Networking Partr Ty svete i DHCP Leased Entries oyster Gd Basic Setting TN Switch Setting east 4 Admin Password 1 Auto 192 168 0 3 0012 770 0530 604785 a IP Configuration S Time Setting Gd DHCP Server a Server Configuration Leased Entries G Backup and Restore IN Firmware Upgrade re TN Factory Default 4 System Reboot Reload C Port Configuration D 4 2 6 Backup and Restore With the Backup command you can save current configuration files saved in the switch s flash to the admin PC or TFTP server This will allow you to go to the Restore command later in order to restore the configura
88. sablanca Monrovia 26 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna GMT 01 00 Belgrade Bratislava Budapest Ljubljana Prague GMT 01 00 Brussels Copenhagen Madrid Paris GMT 01 00 Sarajevo Skopje Sofija Vilnius Warsaw Zagreb GMT 01 00 West Central Africa GMT 02 00 Athens Istanbul Minsk GMT 02 00 Bucharest GMT 02 00 Cairo GMT 02 00 Harare Pretoria GMT 02 00 Helsinki Riga Tallinn GMT 02 00 Jerusalem GMT 03 00 Baghdad GMT 03 00 Kuwait Riyadh GMT 03 00 Moscow St Petersburg Volgograd GMT 03 00 Nairobi GMT 03 30 Tehran GMT 04 00 Abu Dhabi Muscat GMT 04 00 Baku Tbilisi Yerevan GMT 04 30 Kabul GMT 05 00 Ekaterinburg GMT 05 00 Islamabad Karachi Tashkent GMT 05 30 Calcutta Chennai Mumbai New Delhi GMT 05 45 Kathmandu NA NSA Fr TT Fr Fr TT eee eee eC SN 26 korenix GMT 06 00 Almaty Novosibirsk 51 GMT 06 00 Astana Dhaka 52 GMT 06 00 Sri Jayawardenepura 53 GMT 06 30 Rangoon 54 GMT 07 00 Bangkok Hanoi Jakarta 55 GMT 07 00 Krasnoyarsk 56 GMT 08 00 Beijing Chongqing Hong Kong Urumqi 57 GMT 08 00 Irkutsk Ulaan Bataar 58 GMT 08 00 Kuala Lumpur Singapore 59 GMT 08 00 Perth 60 GMT 08 00 Taipei 61 GMT 09 00 Osaka Sapporo Tokyo 62 GMT 09 00 Seoul 63 GMT 09 00 Yakutsk 64 GMT 09 30 Adelaide 65 GMT 09 30 Darwin 66 GMT 1
89. sesseeesseseesesenssseaeeeeseeoeeeees 3 Sch hardware IAMOGUCHOM ee ed 3 22 WNG he de e 5 23 Wiring Digital OUMU scrii naie ea 6 24 Wiring Eanth Ground RE 6 2 5 Wiring 10 100Base TX Fast Ethernet Ports cccceeeceeseeeeeees 6 2 6 Connecting Powered Device Pin 7 2 Wiring RS 232 Console Cable and pin assgnment 8 2 8 DIN Rail Mounting Installation cc cceccssseeeeseeeeeeeeeeeeseeeeeeens 9 29 TTC Ee Lag la EE e BEE 9 Preparation for Management cceesecseeeeeeeeeneeeeenseeseeneees 10 3 1 Preparation for Serial Console cccceceseeeseeeeeeeeseeeeeeeeeeeaeeeses 10 3 2 Preparation for Web Interface cccceecccccseseeeeeeeeeeeeeeessaeeeeeeeas 11 3 3 Preparation for Telnet Console sennaeennnnnnneennnenennennnennosrnn reenn 13 Feature order 16 4 1 Command Line Interface CLI Introduction ceceeeceeeeeeeeees 17 42 EE SCUINGS scenicscee ee dee 22 AS POF COMMGUNATION sss a 37 4 4 Power over Ethernet ccccccsssccccssececceeceecssseeeesseeeseeeeesseeeeeees 40 4 5 Network Redundancy n0annnnneannnnsennnnnnnnnnnosnnrnenenrnnnnnnnrerenrenenne 46 E lee ee 56 bet rafe PFIOMMIZAUOM cesses een ed 59 AO WIGIIGAS TPIT FING EE 63 o lee 67 SET SEENEN eene 71 AA WARING EE 72 4 12 Monitoring and Diagnose 81 AAS Device Front Panel eiogegedeggkseegeheiedd eege SEN EE ege dee 86 ANA Save to PIAS WEE 86 A To MOO OUU EE 87 heien e EE 88
90. t it assigns the port s VLAN identification to the new frame The following commands are included in this section 4 6 1 Management VLAN 4 6 2 Port Based VLAN Configuration 4 6 3 CLI command of Port Based VLAN Management VLAN The Management VLAN ID configuration is for the JetNet 4706 4706f management interface security Only the management packet with the same VLAN ID will forward to a CPU interface You can assign an ID number from 1 to 4094 then click Apply to assign Management VLAN ID The following is the UI interface Management VLAN ID i we Port Based VLAN Configuration PVID The abbreviation of Port VLAN ID Enter the port VLAN ID here PVID allows the switches to identify which port belongs to which VLAN To keep things simple it is recommended that PVID is equivalent to VLAN IDs The values of PVIDs are from 1 to 4094 But O and 4095 are reserved You can not input these 2 PVIDs 1 is the default value 2 to 4094 are valid and available in this column Type the PVID you d like to configure here Allow Send To This column defines the port that traffic could be forwarded to You can click the icon to join the port as a Port Based VLAN group The following figure is the Web user interface for Port Based VLAN configuration fi Miir d cen el to SL DL a l al L LI 1m et C auraen Tanana Kaka Gi rrn r i S Prca i i i l S l i i i l i E O 0O 0O a A Untagged j Egress Tagged Untagged Each p
91. tart vi Device Warm Start el Power 1 Failure Il Power 2 Failure Authentication Failure Time Synchronize Failure el Fault Relay wl Super Ring Topology Change Port Event Selection PoE Event Selection Enable si Enable s Enable s Enable s 3 LinkDown w 3 Disable s 4 Disable s o Disable s 6 Disable s Apply Once you have finished configuring the settings click on Apply to apply your configuration 4 11 3 SysLog Configuration System Log is useful in providing the system administrator both local and remote monitoring of the switch s history There are 2 System Log modes provided by JetNet 4706 4706f local mode and remote mode Local Mode In this mode JetNet 4706 4706f will print selected past events Selected in the Event Selection page to the System Log table of JetNet 4706 4706f You can monitor the system logs in the Monitor and Diag Event Log page Remote Mode The remote mode is also known as Server mode in the JetNet 4500 series In this mode you should assign the IP address of the System Log server JetNet 4706 4706f will send the selected occurrences selected on the Event Selection page to the System Log server that you have assigned Both The 2 modes mentioned above can be enabled at the same time Warning SysLog Configuration pr the syster logs in the Monitor and Diag Event Log page JetNet 4706 4706f Industrial Managed PoE Switch 76 kor
92. tch 4 korenix Side View On the right side of the JetNet 4706 4 706f Industrial Managed PoE Switch there is a terminal block connector and earth ground screw The terminal block connector includes 2 power inputs and 1 relay alarm output Earth Ground 2 2 Wiring Power Inputs Follow the steps below to wire JetNet 4706 4706f redundant DC power inputs Alarm Relay Output 1A DC 24V Power 2 V V 1 Make sure the power terminal block is unplugged 2 Insert the positive and negative wires into the respective V and V terminal block connector contacts Tighten the wire clamp screws to prevent DC wires from becoming loose Power 1 and Power 2 support power redundancy and polarity reverse protection functions 5 Positive and negative power system inputs are both accepted but Power 1 and Power 2 must apply the same mode Note 1 Remember to unplug the power terminal block before making wire connections Otherwise your screwdriver can inadvertently short your terminal connections to the grounded enclosure Note 2 Suitable electric wire ranges from 12 to 24 AWG Note 3 If the 2 power inputs are both connected JetNet 4706 4706f will be powered from the highest connected voltage The unit will signal an alarm for loss of power in either PWR1 or PWR2 korenix 2 3 Wiring Digital Output JetNet 4706 4706f provides one digital output also known as Relay Output The relay contacts are energized open for normal o
93. tch acts as the TFTP client Before you do so make sure that your TFTP server is ready Then type in the TFTP Server IP address This mode can be used in both Web UI and CLI TFTP Server IP Address Key in the IP address of your TFTP Server here Firmware File Name View the file name of the new firmware 31 korenix The UI also shows you the latest firmware version and build date Please check the version number after you reboot the switch The following Web UI is for Firmware Upgrade Local File mode Firmware Upgrade System Firmware Version v0 0 9 System Firmware Date 20070514 Firmware Upgrade Local File X me BJetNet4706 v0 0 8 bin JC Mote When firmware Upgrade is finished the switch will restart automatically Upgrade Click on the Folder icon to select the target file you want to backup restore The following Web UI is for Firmware Upgrade TFTP Server mode Firmware Upgrade System Firmware Yersion v0 0 9 System Firmware Date 20070514 Firmware Upgrade TFTP Serer fi 92 168 10 200 jetnet4 70e vil bm Mote When firmware Upgrade is finished the switch will restart automatically Upgrade Type in the IP address of the TFTP Server and the Firmware File Name Then click Upgrade to start the process After finishing the transmission of the firmware the system will copy the firmware file and replace the firmware in the flash The CLI will show until the process is finished
94. tication username admin username and password admin 79 korenix password MTP Email Alert set authentication Username admin Password admin Note You can assign string to username and password etNet 4706 config no smtp server enable email alert MTP Email Alert set disable ok Disable Authentication UetNet 4706 config no smtp server authentication MTP Email Alert set Authentication disable ok Dispaly etNet 4706 sh smtp server MTP Email Alert is Enabled Server 192 168 10 100 Account admin korenix com Authentication Enabled Username admin Password admin SMTP Email Alert Receipt Receipt 1 korecare korenix com Receipt 2 Receipt 3 Receipt 4 Disable SMTP 80 korenix 4 12 Monitoring and Diagnostic JetNet 4706 4706f provides several types of features for you to monitor the status of the switch or create a diagnostic for you to check the problem when issues with the switch occur Features include MAC Address Table Port Statistics Port Mirror Event Log and Ping The following commands are included in this section 4 11 1 MAC Address Table 4 11 2 Port Statistics 4 11 3 Event Log 4 11 5 Ping 4 12 1 MAC Address Table JetNet 4706 4706f provides 2K of entries in the MAC Address Table On this page users can change the Aging time add Static Unicast MAC Address monitor the MAC address or sort them by different packet types and ports Click on Apply to change the value Aging Time Sec
95. tion file back to the switch Before you restore the configuration file you must place the backup configuration file into the PC or TFTP server The switch will then download this file back to the flash There are 2 modes for users to backup restore the configuration file Local File mode and TFTP Server mode Local File mode In this mode the switch acts as the file server Users can browse the target folder and then type in the file name to backup the configuration Users can also browse the target folder and select existing configuration files to restore the configuration back to the switch This mode is only provided by Web UI CLI is not supported TFTP Server mode In this mode the switch acts as TFTP client Before you do so make sure that your TFTP server is ready Then type in the IP address of the TFTP Server The system uses the default configuration file name Quagga conf You do not need to enter a new file name This mode can be used in both Web UI and CLI TFTP Server IP Address Key in the IP address of your TFTP Server here Backup Restore File Name The system uses a default file name Configuration File The configuration file of the switch is a text file You can open it with Microsoft Word or any program that can read txt files modify the file add remove configuration settings and then restore it back on to the switch 29 korenix Startup Configuration File After you have saved the running config to flash the n
96. to view the current settings and status of the port Path Cost Enter a number between 1 and 200 000 000 This value represents the cost of the path to the other bridge from the transmitting bridge at the specified port Priority Enter a value between 0 and 240 using multiples of 16 This is the value that decides which port should be blocked by priority in a LAN Admin P2P Some of the rapid state transitions that are possible within RSTP depend upon whether the port of concern can only be connected to another bridge i e it is served by a point to point LAN segment or if it can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows P2P status of the link to be manipulated administratively Auto means to auto select P2P or Share mode P2P means P2P is enabled while Share means P2P is disabled Admin Edge A port directly connected to the end stations cannot create a bridging loop in the network To configure this port as an edge port set the port to the Enable state Once you have finished your configuration click Apply to save your settings 4 5 2 RSTP Info This page allows you to see the information of the root switch and port status Root Information You can see Root Bridge ID Root Priority Root Port Root Path Cost and the Max Age Hello Time and Forward Delay of BPDU sent from the root switch Port Information You can see port path cost port priority P2P mode Edg
97. u send to the switch SSH is a client server architecture in which JetNet 4706 4 706f is the SSH server When you want to make a SSH connection with the switch you should download the SSH client tool first SSH Client There are many SSH clients you can find on the internet Fox example PuTTY is a free and popular Telnet SSH client We will use this tool to demonstrate how to log in to the JetNet 4706 4706f through SSH Note PuTTY Copyright 1997 2006 Simon Tatham Download PuTTY http www chiark greenend org uk sgtatham putty download html 13 korenix 1 Open SSH Client PuTTY In the Session configuration enter the Host Name IP Address of your JetNet 4706 4706f and Port number default 22 Choose the SSH protocol Then click on Open to start the SSH session console gt t PuTTY Configuration Category Session Lagging Terminal Keyboard Bell Features CG Window Appearance 7 Behaviour Translation 7 Selection Colours Connection Proxy Telnet Rlogin SSH Tunnels Bugs Basic options for your Pul TY session Specify your connection by host name or IF address Host Name or IF address Port 192 168 10 17 E Protocol Raw O Rogn SSH Load save or delete a stored session Telnet Saved Sessions Default Settings Load Close window on exit C Aways Never Only on clean ext 2 After clicking on Open you w
98. undancy with 5ms backup time when the main path is disconnected and also integrates the 2004 edition of IEEE 802 1d standard for Rapid Spanning Tree protocol including STP function To obtain superior transmission performance JetNet 4706 4706f adopts QoS function with WRR forward scheduling and Port based VLAN These features make sure real time service can be processed with low forwarding latency JetNet 4706 4706f provides various software features including PoE schedule control and Link Partner Live Detect Function LPLD Port based VLAN DHCP Client Server IGMP snooping IGMP query RSTP Network Time Protocol NTP Rate Control and firmware upgrade functions In particular the Link Partner Line Detect LPLD and PoE Scheduling Control functions can save maintenance time and effort with pre defined scheduling control and auto recovery of remote devices without a manual reboot JetNet 4706 4706f uses IP 31 aluminum mechanical housing to deliver superior thermal radiation and protection for non stop operation under high operating temperatures In addition JetNet 4706 4706f supports comprehensive and user friendly management interfaces including SNMP Web interface Telnet and local RS 232 console with Command Line Interface CLI and JetView Most commands are familiar with Cisco products and do not need to relearn rules with the exception of PoE control commands To build a smart cost efficient IP surveillance infrastructure JetNet 4
99. will be updated to the MAC address table 81 korenix WAC Address Table Aging Time Sec 304 Apply Static Unicast MAC Address igs eee ee J CH I e Pal 1c ES D CT ren e Add MAC Address Table All e MAD Tele texte ge IL el el K n den de La WAC Address Address Type UO b Chi Dynamic Unicast SYL r J Di Fee Reload 4 12 2 Port Statistics On this page you can view operational statistics for each port The statistics that can be viewed include Link Type Link State Rx Good Rx Bad Tx Good and Collision Rx means the received packets while Tx means the transmitted packets The statistics can just show Rx Good and Tx Good or Rx Bad and Collision Note If you see an increase in Bad or Collision counts this may mean that your network cable is not connected correctly or the network performance of the port is poor Please check your network cable Network Interface Card connected to your device the network application or reallocate the network traffic Click on Clear Selected to reset the counts of the selected ports and on Clear All to reset the counts of all ports Click on Reload to refresh the counts Also Click on Bad Collision Mode to change counter mode to RxBad and TxCollisions mode and on Good Mode button to change counter mode to RxGood and TxGood mode Note If the mode is changed The statistics counter will be reset to 0 JetNet 4706 4706f Industrial Managed PoE Switch 82 kor
100. ws you each security IP address you have added You can hit Remove to delete and Reload to reload the table Add Security IP fi 92 168 10 200 Add Security IP List 192 168 110 200 Remove Reload Once you have finished configuring the settings click on Apply to apply your configuration korenix 4 10 2 CLI Commands for Security Command Lines for Security configuration Feature Command Line IP Security IP Security etNet 4706 config ip security et ip security enable ok etNet 4706 config ip security host 192 168 10 33 Add ip security host 192 168 10 33 ok Display etNet 4706 show ip security ip security is enabled 4 11 Warning JetNet 4706 4706f provides several types of warning features for remote monitoring and even provides a real time alert mechanism These features include a System Log for local and remote servers SMTP E mail alerts and a Fault Relay alarm The following commands are included in this section 4 10 1 Fault Relay Setting 4 10 2 Event Selection 4 10 3 Syslog Configuration 4 10 3 SMTP Configuration 4 11 1 Fault Relay Setting JetNet 4706 4706f provides 1 digital output also known as Relay Output The relay contacts are energized open for normal operation and will close under faulty conditions Faulty conditions include Power Failure Ethernet port Link Failure Ping Failure and Super Ring Topology Change You can enable and select relay trigger by clicking A
101. zation Guery Waximnun Response Timers fi 0 o CT Multicast Filtering a IGMP Snooping L IGMP Query o Eg SNMP This page allows user to configure the IGMP Query feature Since JetNet 4706 4706f can only be configured by the member ports of the management VLAN so that the IGMP Query can only be enabled on the management VLAN If you want to run IGMP Snooping feature in several VLANs you should notice that whether each VLAN have their own IGMP Querier first The IGMP querier periodically sends query packets to all end stations on the LANs or VLANs that are connected to it For networks with more than one IGMP querier a switch with the lowest IP address becomes the IGMP querier In the IGMP Query selection you can select V1 V2 or Disable V1 means IGMP V1 General Query The query will be forwarded to all multicast groups in the VLAN V2 means IGMP V2 Specific Query The query will be forwarded to specific multicast groups Disable allows you to disable the IGMP Query Once you finish configuring the settings click on Apply to apply your configuration 4 8 3 CLI Commands of the Multicast Filtering The Command Lines of the multicast filtering configuration IGMP Snooping IGMP Snooping etNet 4706 config ip igmp snooping Global IGMP snooping is enabled globally Please specify on which vlans IGMP snooping enables Disable IGMP Snooping JetNet 4706 config no ip igmp snooping Global IGMP snooping is disabled globally ok

Download Pdf Manuals