Home

CP5-Series User Manual - American Weigh Scales

image

Contents

1. ScaleMate User Manual SM 200 200 x 0 019 SM 500 500 x 0 1g SM 501 500 x 0 01g SM DR 100x0 01g 500x0 1g Copyright 2010 American Weigh Scales Inc All rights reserved Rev 2 0 SCALEMATE Thank you for purchasing the American Weigh ScaleMate digital pocket scale Please read all operating instructions carefully before use Scales are precision measuring devices and should always be handled with proper care To ensure years of reliable service keep these simple tips in mind Do not exceed the scale s maximum capacity Overloading your scale can permanently damage it Avoid exposure to extreme heat or cold Scales perform best at normal room temperature If temperatures have changed dramatically calibration and adjustment may be necessary Allow your scale to warm up for 30 60 seconds before performing calibration and adjustment if available Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction Avoid using your scale in close proximity to strong radio wave emitting devices such as computers cash registers and cordless phones Always weigh on a flat and level surface free from vibrations and drafts The corner of a room is usually the most stable Gently apply all items to be weighed Do not drop items onto the weighing platform Avoid dropping your scale The warranty does
2. VI Using the Tare Feature You can use this scale s tare feature to subtract the weight of an empty container or vessel for net weight determination NOTE The weight of the container will subtract from the available capacity 1 Place the empty container or vessel on the weighing platform 2 Press the TARE key once The display will then reset to zero If the container is removed it s weight will be displayed as a negative number 3 You may now fill the container with the quantity to be weighed The display will show the net weight of the contents 4 To return to normal weight display gross weight remove any items from the weighing platform and press the TARE key again to re zero the scale Vil Calibration Calibration and adjustment are performed at the factory However the weighing range can shift slightly during shipping Also due to changes in local acceleration of gravity around the world adjustment is recommended when moving the scale from one location to another To check calibration 1 Place the required calibration weight on the scale and note the displayed value 2 If the displayed value is not within acceptable tolerance see chart below adjustment is required Model Acceptable Calibration Recommended Tolerance Weight Accuracy Class OIML M2 SM 500 0 2g OIML M2 SM 501 0 02g 500g OIML M2 SM DR 0 2g 500g OIML M2 Can be changed to 100g during calibration by press
3. 10 Year Limited Warranty SM 501 Max Capacity 500g 100g Readability 0 01g 0 01g 0 1g 2 x AAA Batteries Platform Dimensions 2 5 x 2 8 Scale Dimensions 0 8 x 2 9 x 4 4 Warranty 10 Year Limited Warranty XI Capacity Readability Charts 200x0 01g 500x0 1g 7 05x0 0010z 17 64x0 010z 128 6x0 01dwt 321 5x0 1dwt 6 43x0 001ozt 16 08x0 01ozt 1000x0 05ct 2500x0 5ct 3089x0 1gn 7716x1gn 500x0 01g 17 64x0 0010z 321 5x0 01dwt 16 08x0 0010zt 2500x0 05ct 7716x0 1gn 100x0 01g 3 528x0 0010z 64 30x0 01dwt 3 215x0 001ozt 500x0 05ct 1543x0 1gn 500x0 1g 17 64x0 010z 321 5x0 1dwt 16 08x0 01ozt 2500x0 5ct 7716x1gn
4. ing TARE See Section VIII Vill Adjustment 1 Turn the scale on by pressing the ON key 2 Wait for the display to show 0 0g or 0 00g then press and hold the ON key for a few seconds until the display shows 0 then release 3 The display will flash g along with the default calibration weight value see chart above Place the SCALEMATE required weight on the center of the platform If you wish to change the weight to 100g press the TARE key before placing the weight on the scale 4 Once the weight is confirmed the g will stop flashing on the display and calibration is complete IX Troubleshooting Problem Scale will not turn on Solution Check the batteries Problem Displayed weight fluctuates randomly Solution Make sure your workspace is stable and free of any air currents or vibration Problem Displayed weight is inaccurate Solution Perform a calibration adjustment X Error Codes 1 OUTZ Zero range has shifted Perform calibration adjustment If the problem persists the load cell may be permanently damaged due to overloading 88888 Maximum capacity exceeded Remove the extra weight to avoid damaging the load cell L Batteries are low Replace the batteries SM 200 SM 500 Max Capacity 200g 500g Readability 0 01g 0 1g 2 x AAA Batteries Platform Dimensions 2 5 x 2 8 Scale Dimensions 0 8 x 2 9 x 4 4 Warranty
5. not cover damage due to rough treatment or overload Check the batteries first if you are having any trouble with your scale This simple step can remedy most scale issues Do not disassemble your scale This product contains no user serviceable parts I Part List 1 Scale 2 Removable Cover Tray 3 AAA Batteries x2 Il Key Description Power OFF Power ON CAL Mode Key Tare Key Ill Battery Installation 1 Before using the scale for the first time check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping storage 2 If you are replacing the batteries make sure the positive and negative contacts are properly aligned SCALEMATE IV Operation 1 Place the scale on a flat level surface and press the ON key to turn the scale on 2 Once the start up process completes and the scale goes to zero you are ready to weigh 3 Place the quantity to be weighed onto the weighing platform 4 Wait a couple seconds for the display to stabilize before taking a weight reading V Changing the Unit of Measure 1 Press the MODE key to change the scale s displayed unit of measure 2 If the scale is turned off then back on it will default to the last unit used SCALEMATE Units All Models g gram oz ounce dwt pennyweight ozt troy ounce ct carat gn grain

Download Pdf Manuals

image

Related Search

Related Contents

2. Preparations - Pro Video Systems  Strata Messaging Voice Mail User Guide - Toshiba  TrendViewer Lizenzbedingungen  Coby TFDVD8503  HP Z220 SFF/CT Workstation  ZyXEL GS2200-8/24 User's Manual  A-Offre-SushiCatalogue-2014 Janv-FrancaisEuro  Manual (english)  Manual de usuario Grabador  Argos2D - D12x  

Copyright © All rights reserved.
Failed to retrieve file