Home

WaSP-F1 Low Flow Controller USER MANUAL

image

Contents

1. O O INTRODUCTION This manual covers the operation and maintenance of the WaSP F1 Low Flow Controller This manual should be considered a permanent part of the WasSP F1 Low Flow Controller and should remain with it if it is sold If a problem should arise or if you have any questions please contact Waterra UK Ltd Waterra UK Limited reserves the right to make changes at any time without notice and without incurring any obligation No part of this publication may be reproduced without written permission Why use the WaSP F1 Low Flow Controller The WaSP F1 Low Flow Controller is an easy to use and robust solution for progressively varying the voltage supply to a 12V submersible pump in a precise and controlled way The WaSP F1 Low Flow Controller design features include e Universal voltage controller suitable for any non boosted 12V device with up to 25 Amps current draw Single on off dial with precision control of flow rate Splash proof sealed housing Intelligent electronics with built in safety features LED warning signal Light weight 1 6 kg and compact Robust aluminium housing Explanation of Symbols The Waterra WaSP F1 Flow Controller is designed to give safe and dependable service if operated according to instructions Read and coy understand the Owner Manual before operating the Flow Controller Failure to do so could result in personal injury or equipment damage The Waste Electrical and Electroni
2. N 61000 4 4 Immunity to Fast Transient Bursts And meets the relevant requirements of BS EN 60335 General Requirements for Household and Similar Electrical Appliances Authority ME Peter Dumble Technical Director Waterra amp ln Situ 1 SPECIFICATIONS It is the policy of Waterra In Situ to continually review and update product design therefore some details may differ from the actual product sold All dimensions are approximate and include protrusions Input Voltage Output Voltage Maximum Load Safety Protection 12V DC 01 12V DC 25 Amps Input connection Maximum load Internal protection Low input voltage High input voltage Environment Height Weight Input cable length Controls Status LED Rotary flow control dial Connections Input cable Output terminals Waterra Hin Situ P Reverse polarity protected Load current limiter set to 25 Amps Internally fused to 30 Amps Unit cut out for input voltage below 8 3V Unit cut out for input voltage above 16V 11 7 cm 1 6 kg 1 metre Steady correct operation Slow flash low input voltage warning Rapid flash high input voltage warning On Off switch Varies voltage output from 0 to maximum Twin core cable with insulated crocodile clips for connection to a 12V DC battery Threaded positive and negative terminal posts and nuts suitable for crocodile clips or for cable connection TROUBLESHOOTING Before contactin
3. Q 7 gt u LOW FLOW CONTROLLER 1 WaSP F1 Low Flow Controller USER MANUAL Issue 3 Waterra amp DiIn Situ j Innovations in Water Monitoring Waterra UK Limited Unit 4 r o 179 189 Stratford Road Shirley Solihull West Midlands B90 3AU United Kingdom Tel 44 0 121 733 7743 Fax 44 0 121 733 7746 Email Sales Waterra In Situ com Web www Waterra In Situ com Copyright Waterra UK Limited 2012 Waterra UK Limited is a wholly owned subsidiary of In Situ Inc TMO7 20120814 TMO7 20120814 SERVICE CONTENTS Service Address Waterra UK Limited EC Declaration of Conformity cccccccssccseesescescseseescesseveveeseceecerveveuersateaceeeeves Unit 4 r o 179 189 Stratford Road l Shirley MOGUCIM ee E S 2 Solihull Why use the WaSP F1 Low Flow Controller oocococcocccoocnccconcconnno 2 West Midlands Explanation of SyMboOlS ooocococcnncccncconcnononncocononnnnnonccnnnnnnnnnnononancnncncnonannnnos 2 B90 SAU Component Identification ooccooncccconcnononcccccnnnnoncnnnnnnononcnonononenononnoninonos 3 United Kingdom Operation E a cra rr anne 4 Tel 44 0 121 733 7743 Connection to Power Supply AA Lerner are enneeenaneannee cnn 4 Fax 44 0 121 733 7746 Connection to 12V Submersible Pump or Other Device oocccoocccoo 4 e o o eR ee ee re eee 4 Email sales Waterra In Situ com Troubleshootin 5 esco APP PA SPECAN aria 6 Guarantee A e ee EEEE E EE A eee ere ne
4. c Equipment Directive WEEE Directive aims to minimise the impact of electrical and electronic goods on the environment by increasing re use and recycling and reducing the amount of WEEE going to landfill It seeks to achieve this by making producers responsible for financing the collection treatment and recovery of waste electrical equipment and by obliging distributors to allow consumers to return their waste equipment free of charge all the appropriate provisions of the relevant legislation implementing CE marking is a declaration by the manufacturer that the product meets certain European Directives Waterra Q9In Situ 2 COMPONENT IDENTIFICATION Components described elsewhere in this manual are referred to in the following diagram Description Crocodile Clips Output Connections Flow Control Dial Status LED i Waterra Din Situ 3 OPERATION The operation of the WaSP F1 Low Flow Controller is straightforward However prior to use for the first time unpack the flow controller and familiarise yourself with the controls and components as described in this manual Connection to Power Supply Note before connection make sure that the Flow Control Dial 3 is in the Off position If a connection is made while the unit is turned on the pump will start operating immediately Connect the WaSP F1 Low Flow Controller crocodile clips 1 to a 12V DC power supply e g car battery For longer battery
5. eer ae ens 7 DEVILS 218 e rene eee ee 7 Warranty Period CUNA Cee ee ee 7 This warranty is not transferable Waterra UK Limited warrants that it will replace or repair at no cost to the customer any defects in material or workmanship for a period of 1 year from date of purchase provided that the unit has only had normal use as described in this manual Warranty Exclusions e Repairs required as a result of accidental damage or use outside the conditions of normal use as described in this manual e Repairs required as a result of any modifications by the user e Repairs required on any unit which has been loaned or rented to third parties by the purchaser See our Terms amp Conditions which can be supplied on request This does not affect your Statutory Rights For Warranty conditions outside the UK and Ireland refer to your local Waterra In Situ dealer Version 3 TM07 201 20814 Waterra In Situ 7 EC DECLARATION OF CONFORMITY Producer Waterra UK Limited Unit 4 r o 179 189 Stratford Road Shirley Solihull West Midlands B90 3AU Description Variable voltage controller to enable low flow pumping with 12V submersible pumps Type WaSP F1 Requirements Meets the relevant emissions and immunity specifications of BS EN 61000 6 2 2005 and BS EN 61000 6 4 2001 Which call up BS EN 55022 Class A Radiated Emissions BS EN 61000 4 2 Immunity to Electrostatic Discharge BS EN 61000 4 3 Immunity to Radiated Fields BS E
6. g Waterra please use the following troubleshooting guide to resolve common difficulties gt as D A c gt O 2 en O O 0 O 0 0 fo 2 m en r 0 D J 0 D D O SE Qu Ua 5 Dr gt O 5 O aS E F SE g 88 4 3 Qu c 5 Q D v o oO ES Ela o D Sa 6 Q o OOo E UU X am D oO O ce oO 32 z E Z oO oO co gt lt gt 2 gt 2 o 3 3 o 3 3 O o T D 2 35 5 Oca COQ oO 5 VIS c Lo Q oO UD 5 Cc oO o 9 eco o gt o x Q 4 O O E os 0 O o Oo 5 2 od ROS 059 oS G Le 229 eo 83 5 PA Do v Ot Gs lt gt O Y Si 9 ZO o 29 gt NSE TD gt L z 30 a ap OSE 05 Da as gt Oe E 8 o Z 570 5 O Sa 55 2 e 23g Ta 23 w Y 530 530 O Y vod oo d VDE OF 0 O coer Ces lt q c Oo c on Evo es 2 Eo Eo E gt x oO o Y D LL E a a a m E O O O O O O on Z Z Z lt O LED Display Flashes slowly Waterra Hin Situ P Check the connections The pump leads are not connected properly O Cc YN O O Q oO Test the pump by connecting directly to the battery There is a problem with the pump Switch the dial on The Flow Control Dial is switched off The Low Flow Controller has been subjected Switch the unit off and back on again O U C O 2 O T 9 m O O O 9 gt gt O lt
7. life Waterra recommend using a heavy duty or marine specification battery When connecting to the power supply ensure that the correct polarity is observed Red to Positive and Black to Negative and that there is no possibility of any bare metal touching between the two connections Connection to 12V Submersible Pump or Other Device Connect the cable from the 12V pump to the WaSP F1 Low Flow Controller Output Connections 2 Where the pump cable has crocodile clips clip these directly onto the output connector posts For cables that end with bare wires loosen the output connector post nuts and then tighten them onto the ends of the wires When connecting the pump to the Low Flow Controller ensure that the correct polarity is observed and that there is no possibility of any bare metal touching between any part of the crocodile clips or output connections Please note Waterra do not recommend the use of the Low Flow Controller with pumps that have a voltage booster Operation Once the power supply and pump are connected correctly turn the Flow Control Dial 3 from the Off position The further the dial is turned clockwise the higher the output voltage to the pump up to the maximum output of 12V To turn the Low Flow Controller Off turn the dial anti clockwise to the Off position until the dial clicks off Waterra Q9In Situ 4