Home

SIENNA Home Connect User Manual V2_2

image

Contents

1. To configure the network interface a switch attached to a SIENNA sensor has to operated 10 times within a time interval of 5 seconds 5 x ON OFF or 5 x PUSH This integrates t the USB network interface with the SIENNA installation enabling it to communicate with the SIENNA modules The SVC LED switches off You can also use the software tool SIENNA Professional to configure the USB network interface The Configurator can be used to reset the USB network interface This deletes the configuration parameters and the SVC LED blinks periodically to indicate the unconfigured state of the network interface see Chap 2 The USB network interface binds all SIENNA devices With group addresses A B C O i e 15 A groups Devices that are to be managed using SIENNA Home Connect must have a group address within this range 3 12 ug 2 Gef SIENNA Home Connect Bedienungsanleitung 2 Configurator The SIENNA Configurator can be used to personalize the functionality of a SIENNA installation The Configurator provides the following features Find all devices in an installation and report their current status Define Edit device names Define Edit scenes and zones Define Edit schedules Reset USB network interface to factory settings The first step is to log on to the configuration page of the FRITZ Box with the password for the FRITZ Box A For a correct display of the Configurator pages you will need
2. 2 7 Reset Factory settings Before the USB network interface can be integrated with a new installation it needs to be reset This can be done with the button RESET USB Interface The USB network interface can then be integrated into the new installation as described in chapter 1 2 A complete reset to factory settings can be done with the button 5 SIENNA Factory settings This deletes all user defined data and settings devices zones scenes schedules etc The reset to factory settings pertains only to the SIENNA data The USB network interface and the settings of the FRITZBox will not be reset If required they must be reset separately 1012 1 Gb SIENNA Home Connect Bedienungsanleitung 3 1 3 2 3 2 1 Operation After configuring the installation all SIENNA devices can be operated using SIENNA Home Connect smart phones tablets or PCs Open the SIENNA Home Connect page in a Sica Zones browser to display links to the pages listing Devices Scenes Zones Dimmer Ri The most frequently visited page can be bookmarked j for direct access from a mobile phone or tablet Switch B5 OFF At home the FRITZ Box and Home Connect can be directly accessed using the WLAN or LAN The Remote Maintenance feature of the FRITZ Box needs to be activated if secure access using the internet is required Alternatively one can also use the MyFRITZ feature for remote access sten tl 21 C Switch BE OF
3. a i e z Jalousie Ai e SIENNA Home Connect V2 2 gt Wiew Licht Wohnen Devices Zones Standlicht e Scenes schedules Licht Diele Help mn is e Refresh Devices Fharreaeta RIS Create Extend apartment ln Standlicht mit Strommessung e BS RESET USB Interface be SIENNA Factory settings Dimmer Fritz Temperaturemode Language amp Schaltaktor 01 gt Heat Cool Deutsch English Zones Scenes Schedules 2013 Secyouril GmbH This view lists all available devices zones scenes and schedules and is the entry point for defining new zones scenes or schedules 50 t Gulf SIENNA Home Connect Bedienungsanleitung 21 Find Refresh SIENNA devices The button Find devices can be used to find all SIENNA devices in the installation Auto discovery The settings and states of all SIENNA devices can be updated by using the button Refresh devices Create Extend apartment a USB network interface not configured A new domain address will be generated for the USB network interface all unconfigured SIENNA devices b USB network interface is configured The USB network interface will bind all unconfigured SIENNA devices to its own domain 2 2 Manage devices The menu item Devices lists all available devices Individual devices can be selected and assigned a meaningful name It is also po
4. for SIENNA Home Connect will now be displayed and all SIENNA devices can now be managed via internet ua eg t Gulf SIENNA Home Connect Bedienungsanleitung 4 Contact Further information about SIENNA Home Connect can be accessed on our webpage http www secyourit com Enquiries about SIENNA Home Connect can be sent by email to support secyourit com i 2 m 1 Gef
5. to use a web browser that supports HTML5 e g Internet Explorer V9 0 or higher The FRITZ Box configuration menu includes the menu item SIENNA Configurator FRitZ Box 7270 Ubersicht Internet Telefonie Heimnetz WLAN DECT System Assistenten FRITZINAS 5 Abmelden CA Ansicht Experte fginhalt 9 Hilfe bersicht FRIT Bon Fon WLAN 7270 v3 Aktueller Energieverbrauch 39 Firmware Version 74 06 04 70708 Vom Hersteller nicht unterst tzte Andenungen Weitere informationen Verbindungen internet verbunden seit 19 06 2012 17 56 Uhr IP Adresse 192 108 2 6 Telefonie Keine Rufnummem eingerichtet Anschl sse Komfortfunktionen DSL deaktiviert Anrufbeantworter LAN verbunden LAN 1 Speicher NAS WLAN an gesichert DECT aus USB kein Ger t angeschlossen Anrufe Netzwerk Keine Anrufe vorhanden S PC 192 168 178 23 WLAN TomPc 1 WLAN mene 0 mehr 4 deaktiviert 259 kB genutzt 4 MB frei Telefonbuch zuletzt bearbeitet D Telnet of 90 8 8 Telnet On 06 7 P Alle Rundruf WW Q AVMAnsage HD 500 h tel Kontakt hunzufugen mer Handbuch j SemicePorai j FAQs j FRITZ Cips 1 Programme 1 www awm e Click on this menu item to open a new window for configuring the SIENNA Installation The current installed version of SIENNA Home Connect is displayed in this view 4 12 Seeyourrt GmbH SIENNA Home Connect Bedienungsanleitung SIENNA Home Connect CONFIGURATOR l DN e
6. Connect is available for the FRITZ Box models 7270v3 and 7390 FW updates may not be restricted by the ISP Internet Service Provider This FW update does not lead to any restrictions of support or guarantee conditions from AVM 1 1 FW update for the FRITZ Box The latest FW Version for SIENNA Home Connect can be downloaded from http www secyourit com fritzbox Please check if the FW version on your FRITZ Box see user manual for your FRITZ Box matches the version available on the web page mentioned above The installed version of SIENNA Home Connect can be found on the Configurator home page see Chap 2 In case your FRITZ Box has a different FW Version please download the FW update and install this update as described in the FRITZ Box user manual gt gt The USB interface should be disconnected before starting the FW update and reconnected only after the update has been successfully completed All further updates should be downloaded from the above mentioned web page since the updates from AVM do not include the SIENNA configuration 1 2 USB network interface l ECHELON The USB network interface connects the USB port of the FRITZ Box to a power outlet If possible this power outlet should not be connected simultaneously with a PC The network interface is delivered in an unconfigured state i e is not attached to the existing SIENNA installation The SVC LED orange blinks periodically every 2 seconds
7. F Switch Bd OFF Load Cz OFF Sunblind C1 OPEN 0 Operation using WLAN LAN After connecting to the FRITZ Box using either WLAN or LAN SIENNA Home Connect can be accessed through the web page FRITZ Box HomeConnect home lua Remote access using Internet There are two ways to establish a secure internet connection to the FRITZ Box Activating the Remote Maintenance feature of the FRITZ Box will allow direct access from the internet This requires that either the FRITZ Box receives a fixed IP Address from the Internet Service Provider or that the Dynamic DNS feature is active Registering the FRITZ Box for the MyFRITZ service from AVM will also allow remote access One can login to the MyFRITZ server from AVM and then establish a secure connection to the FRITZ Box Instructions for both methods mentioned above can be found in the FRITZ Box user manual Remote access using Remote Maintenance o establish a secure internet connection to FRITZ Box activate Remote Maintenance and set the user name and password for access using the internet SIENNA Home Connect can be accessed using the web page external IP Adresse or Domain Name of the FRITZ Box homeconnect home lua f the browser shows a security certificate error then click OK and load the web page This is a property of the FRITZ Box and there is no security risk involved Log in using the previously defined user name and password The user interface
8. SIENNA Home Connect User Manual V2 2 Secyourit GmbH Auenstr 100 80469 Munchen Deutschland Tel 49 89 12294700 Fax 49 89 72430099 Copyright 2012 Secyourit GmbH SIENNA Home Connect Bedienungsanleitung Table of Content L INSTALLATION ee 3 1 1 FV UPDATE FOR THE do LA Ee 3 1 2 USB NETWORK Ch EN 3 2 EONFISURATOR dE 4 21 FIND REFRESH SIENNA poEwcks E E E a a nnn 6 2 2 MANAGE DEVICES eninin dandani aa a wade SwnheinbdeatensadeonlasetcanenimedsebeansdeavatsedudSentaciacet 6 DI EINE EE 7 2A SCENES 2c ee ccesececcccccccccccecccccccccussceccceccecauceeeeccccceuuucceeececccuuusesecceccsuuauseeeceseceuuaseeececcsuuuaceeeccssceuaceeeeeeeeeaas 8 2 4 1 Triggering a scene with a sensor 8 Zb SCHEDULES 2 20 eecccccccssseecccccccccccsceccccccccuuccecccccccuuaceeccccccuuuaseeccccesuuauseeecescseuuuseeececceuuaacesecessesuaaceeeeeceeeaas 9 2 6 m E 10 2 7 RESET FACTORY SETTINGS 10 3 OPE TOWN EEN 11 3 1 OPERATION USING WLAN LAWN ccccccceeccccccccccccccccccccccccesccccccaescececcuccecessaecececeuacsececsaaceeeeeeaees 11 3 2 REMOTE ACCESS USING INTERNET 11 3 2 1 Remote access using Remote Maintenance 11 A CONIAC RE 12 2 12 a 7 Gull SIENNA Home Connect Bedienungsanleitung 1 Installation In order to use SIENNA Home Connect you need to have the Home Connect FW for the FRITZ Box and IN a USB network interface The network interface connects the USB port of the FRITZ Box to a power outlet SIENNA Home
9. all subsequent operations of this sensor will result in the scene being executes If more than one sensor has this address then each sensor will trigger the scene The assignment can be deleted using the button 8da _ a 2 Gell SIENNA Home Connect Bedienungsanleitung 2 5 Schedules The menu item Schedules gt can be used to define select edit or delete schedules a Ls Schedules Schedule list Abends Aus gt Name Abends Aus Day of week Time of day 22 00 Status Active Scene Zentral Aus Add scene 2012 Secyourit GmbH This menu item lists all available schedules and individual schedules can be selected and edited as required There are no pre defined schedules and the user has to define the necessary schedules after the USB network interface has been commissioned A schedule requires a scene which is then executed at a defined time The button creates a new schedule Each schedule has to be assigned a name The Add scene menu item can be used to select a particular scene and to set the time when this scene should be executed The checkbox Active is used to define whether a particular schedule is enabled or not Save The button saves the schedule settings x Delete The button deletes the schedule Al 1 4 Gull SIENNA Home Connect Bedienungsanleitung 2 6 Help The menu item displays this user manual in a browser window
10. ssible to control devices from this page Devices Device bet amp Refresh N Delete s Dave Sunblind EN Licht Wohnen gt ZA Standlicht i aa Address A1 Licht Diele A Name Sunblind A Licht Garten Thermostat B15 A State Down Stop Up Standiicht mit Strommessurg E Open St ap Geet Dimmer Fritz Schakaktor OF Runtime s 10 Display Show device The checkbox Display can be used to define whether a device should be displayed on the user interface 6 12 t Gulf SIENNA Home Connect Bedienungsanleitung 2 0 Zones The menu item Zones can be used to define select edit or delete zones Zones can defined to be e g living room basement garden lights etc A X Zone list Demo Lab gt IN Lab D 3 Device list Switch A3 Add device 2012 Secyourit GmbH This menu item lists all available zones and individual zones can be selected and edited as required There are no pre defined zones and the user has to define the necessary zones after the USB network interface has been commissioned The button creates a new zone Each zone has to be assigned a name The Add device menu item can be used to add individual devices to the zone The checkbox next to each device can be used to add or remove devices from a particular zone v Save The Ges button stores the zone for the user interface x Delete The c button remo
11. ves the zone from the user interface 112 4 Gull SIENNA Home Connect Bedienungsanleitung 2 4 2 4 1 Scenes The menu item Scenes A gt can be used to define select edit or delete scenes ft Scenes any bk Scene list Off Allon test D Cl O 898080 Zentral Aus Trigger with sensor O1 x Remove Device list Switch A3 State CI Add device 2012 Secyourit GmbH This menu item lists all available scenes and individual scenes can be selected and edited as required There are no pre defined scenes and the user has to define the necessary scenes after the USB network interface has been commissioned The button creates a new scene Each scene has to be assigned a name The Add device menu item can be used to add individual devices to the scene and define a particular state for the device v Save Run After ER the scene can be executed to check if the scene definition is correct The EEN button sets all included devices to the state specified in the scene definition The checkbox next to each device can be used to remove a device from a particular scene x Delete The c button removes the scene from the user interface Triggering a scene with a sensor A scene can be triggered by pushing a particular sensor Click on Trigger with sensor and then push the corresponding sensor This assigns the address of this sensor to the scene and

Download Pdf Manuals