Home
User Manual - CyberPower
Contents
1. CyberPower Reliability Quality Value LE825DG CP685AVRLCD G CP825AVRLCD G User s Manual IMPORTANT SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery There are no user serviceable parts inside except for battery CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION The UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the unit CAUTION To avoid electric shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70
2. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect operation safety of any life support equipment any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire or electric shock do not use with or near an aquarium Condensation from the aquarium can cause the unit to short out INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following 1 UPS unit 2 User s manual 3 USB device cable 4 PowerPanel Personal Edition software CD or Free download card WHAT IS AVR The LE825DG CP685AVRLCD G CP825AVRLCD G provide complete power protection from utility power that is not always consistent The LE825DG CP685AVRLCD G CP825AVRLCD G feature 1030 890 1030 Joules of surge protection and provide long lasting battery backup during power outages with maintenance free batteries The LE825DG CP685AVRLCD G CP825AVRLCD G ensure consistent power to your electronic equipment and include software that will automatically save your open files and shutdown your electronic equipment during a utility power loss AUTOMATIC VOLTAGE REGULATOR The LE825DG CP685AVRLCD G CP825AVRLCD G stabilize utility power voltage levels that can be inconsistent The incoming utility power may be damaging to important data files and hardware but with Autom
3. 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life support devices etc What are the Limitations The sole and exclusive remedies to the Initial Customer are those provided by this Warranty 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Product must have been use
4. Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited agreement of CyberPower to provide certain warranty benefits regarding Connected Equipment under this Warranty loss of profits business interruption or loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you 6 The Product is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or with Aquariums ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded CyberPower is the warrantor under this Limited War
5. 1 x 6 6 x 3 5 13 3 Ibs 13 8 Ibs 8 hours typical from total discharge Net Weight Typical Battery Recharge Time Typical Battery Life 3 to 6 years depending on number of discharge recharge cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Safety Approvals UL1778 UPS cUL107 FCC DoC Class B CYBERPOWER GREENPOWER UPS TECHNOLOGY Advanced Energy Saving Patented Bypass Technology CyberPower s patented GreenPower UPS with Bypass Technology reduces UPS energy costs by up to 75 compared to conventional UPS models Even when utility power is normal conventional UPS models constantly pass power through a transformer By contrast under normal conditions the advanced circuitry of a GreenPower UPS bypasses the transformer As a result the power efficiency is significantly increased while decreasing waste heat using less energy and reducing energy costs ENERGY SAVING TECHNOLOGY When an abnormal power condition occurs the GreenPower UPS automatically runs power through its transformer to regulate voltage and provide safe power Since utility power is normal over 88 of the time the GreenPower UPS operates primarily in its efficient bypass mode The GreenPower UPS is also manufactured in accordance with the Restriction on Hazardous Substances ROHS directive making it one of the most environmentally friendly on the market today Limited Warranty and Co
6. atic Voltage Regulation the computer will not experience damaging voltage levels An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent computer safe 110v 120v The unit s powerful battery will provide power only if the incoming voltage drops below 90v or increases above 140v SYSTEM FUNCTIONAL BLOCK DIAGRAM Surge Normal Mode lt a Battery Mode EEEE p Battery HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the UPS does not exceed the UPS unit s rated capacity 685VA 390W for CP685AVRLCD G 825VA 450W for LE825DG CP825AVRLCD G If the rated capacities of the unit are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your electronic equipment will require It is suggested that the load you will be placing on the outlet not exceed 80 of the unit s capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least 8 hours is recommended to ensure that the battery s maximum Fi Sal LS gt D charge capacity is achieved A loss of charge may occur during shipping and storage fi aN Ly si To recharge the battery simply leave the unit plugged into an AC outlet Bee ir oe 2 With the UPS unit off and unplugged connect your comput
7. cpsww com Circuit breaker has been tripped due to an overload The UPS does not perform runtime i expected runtime Battery is worn out The on off switch is designed to prevent damage by rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The unit is not connected to The unit must be connected to a 110 120v 60Hz outlet an AC outlet The UPS will not turn on Contact CyberPower Systems about replacement batteries at tech cpsww com The battery is worn out Mechanical problem Contact CyberPower Systems at tech cpsww com Connect the USB cable to the UPS unit and an open USB port on the back of the computer You must use the cable that came with the unit The USB cable is not a connected PowerPanel Personal Edition is inactive all icons are gray The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit Additional troubleshooting information can be found at www CPSww com TECHNICAL SPECIFICATIONS CP825AVRLCD G LE825DG 120Vac 5 Max Load for UPS Outlets 4 Outlets 685VA 390W 825VA 450W Max Load for Full Time Surge Protection outlets 8 Outlets 12 Amps Simulated Sine Wave Form 32 F to 104 F 0 C to 40 C On Battery Output Wave Form Operating Temperature Operating Relative Humidity 0 to 90 NON CONDENSING Size W x H x D 1
8. d at all times within the limitations on the Products VA Watt capacity The Product was designed to eliminate disrupting and damaging effects of momentary less than 1ms voltage spikes or impulses from lightning or other power transients If it can be shown that a voltage spike lasting longer than 1ms has occurred the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmission or fluctuations or by transients in such transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment 5 CyberPower excludes any liability for personal injury under the
9. e made within ten days of the occurrence What Will We Do To Correct Problems CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our maximum liability is limited to 125 000 for the CP685AVRLCD G and 200 000 for the LE825DG CP825AVRLCD G Who Pays For Shipping We pay when we send items to you you pay when you send items to us What isn t covered by the warranty A This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software
10. ed into a grounded and properly wired wall outlet Communication Protection Ports Communication protection ports will protect any standard modem fax telephone line network or Ethernet connection RJ11 RJ45 Circuit Breaker Located on the side of the UPS the circuit breaker serves to provide overload and fault protection USB Port Allows for connection and communication between the USB port on the computer and the UPS unit The UPS communicates its status to the PowerPanel Personal Edition software Outlets Designed for AC Adapters The unit has four outlets spaced to allow AC power transfomers to be plugged into the UPS without blocking overlapping or blocking adjacent outlets Coax Cable DSS Surge Protection The Coax Cable DSS surge protection ports will protect any cable modem CATV converter or Te ae eae a DSS receiver ee Ff m 4 ae LCD Module Display D mA m hs Crystal Blue intelligent LCD panel shows all the UPS information using icons and messages For more information please check the Definitions for Illumination LCD Indicators section below The LCD display indicates a variety 2 LCD Panel Toggle Switch of UPS operational conditions All The switch can be used to select the LCD panel displayed information including Input Voltage descriptions apply when the UPS is Output Voltage and Estimated Run Time The toggle frequency is set to one time per second plugged into an AC outlet and turned Holding the switch f
11. er monitor and any other peripherals requiring battery backup into the battery power supplied outlets Plug your other peripheral equipment printer scanner speakers into the full time surge protection outlets DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical device into battery and surge protected outlets The power demands of these devices will overload and possibly damage the unit 3 To protect a network connection from surges connect a network cable into the IN jack of the UPS Then connect a network cable from the OUT jack on the UPS to the network device 4 Plug the UPS into a 2 pole 3 wire grounding receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air conditioner refrigerator copier etc The warranty prohibits the use of extension cords outlet strips and surge strips in conjunction with the UPS unit 5 Press the power switch to turn the unit on The power on indicator light will illuminate and the unit will beep 6 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Make sure the circuit breaker is depressed and then turn the UPS on 7 To maintain optimal battery charge leave
12. may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS TO REPLACE THE BATTERY Turn off and unplug all connected equipment Unplug it from the AC power source Turn the UPS upside down Remove the 1 retaining screw Slide the battery compartment cover completely off of the unit Remove the battery from the compartment Disconnect the battery wires from the battery Install the replacement battery by connecting the red wire and black wire to the positive and negative terminal of the battery Put the battery back into the compartment Slide back the battery compartment cover and tighten the retaining screw Charge the unit for 4 8 hours Ta O 0 D Oh dee De O REMINDER Batteries are considered HAZARDOUS WASTE and must be disposed of properly Most retailers of lead acid batteries collect used batteries for recycling as required by local regulations TROUBLE SHOOTING Problem Fossile Gauss Somon Full time surge protection outlets stop providing power to equipment Circuit breaker button is projecting from the side of the unit Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by pressing the button and then turn the UPS on Battery not fully charged Recharge the battery by leaving the UPS plugged in Contact CyberPower Systems about replacement batteries at tech
13. n off your equipment immediately OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops BATT CAPACITY meter This meter displays the approximate charge level in 20 increments of the UPS s internal battery During a blackout or severe brownout the UPS switches to battery power the BATTERY icon appears and the charge level decreases LOAD CAPACITY meter This meter displays the approximate output load level in 20 increments of the UPS s battery outlets 5th Return Press gt 3sec Sound Disable Press gt 3sec again Sound Enable V light up go out not available ES ES ES EJ Ez Ea Si JET esc SS BESES REPLACING THE BATTERY Replacement of batteries located in an OPERATOR ACCESS AREA 1 When replacing batteries replace with the same number of the following battery RB1280 for CP685AVRLCD G RB1280A for LE825DG CP825AVRLCD G 2 CAUTION Risk of Energy Hazard 12V maximum 8 CP685AVRLCD G or 9 LE825DG CP825AVRLCD G Ampere hour battery Before replacing batteries remove conductive jewelry such as chains wrist watches and rings 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It
14. nnected Equipment Guarantee Read the following terms and conditions carefully before using the CyberPower LE825DG CP685AVRLCD G CP825AVRLCD G the Product By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Connected Equipment Guarantee together referred to as this Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Who is Providing this Warranty CyberPower Systems USA Inc CyberPower provides this Limited Warranty What Does This Warranty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions It also covers equipment that was connected to the Product and damaged because of the failure of the Product What is the Period of Coverage This warranty covers the Product for three years Connected equipment is covered for as long as you own the Product Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12 Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipmen
15. oad of Batt Lim A T Ce eea a Ca eea e of e J Lo je a e a fd dle Lm esajar y dae ww e ie tet a sy pe ie lt eee ee ee e V light up X go out not available Battery mode Select SW Press UPS Status Display Capacity Display Digital Value Display 100 Load Battery Input Output Run INPUT voltage meter The UPS is designed to continuously supply connected equipment with stable output voltage In the event of a complete power loss severe brownout or over voltage the UPS relies on its internal battery to supply consistent 110 120 output voltage The INPUT voltage meter can be used as a diagnostic tool to identify poor quality input power OUTPUT voltage meter This meter measures in real time the AC voltage that the UPS system is providing to the computer during normal line mode and battery backup mode ESTIMATE RUN TIME This displays the run time estimate of the UPS with the current battery capacity and load NORMAL icon This icon appears when the UPS is working under normal conditions BATTERY icon During a severe brownout or blackout this icon appears and an alarm sounds two short beeps followed by a pause to indicate the UPS is operating from its internal batteries The alarm will continue to sound during a prolonged brownout or blackout The BATT CAPACITY meter will show one 20 capacity segment remaining to indicate the UPS s batteries are nearly out of power You should save files and tur
16. or more than two seconds while running on battery will silence the buzzer on or when the UPS is on battery DEFINITIONS FOR ILLUMINATED INDICATORS DEFINITIONS FOR ILLUMINATED LED INDICATORS T q CONDITION Power ON Wiring Fault Alarm A Beep twice r Failure The UPS is providing power to battery power supplied outlets On every 30 seconds from the battery A Rapid Beeping Utility Failure The UPS is providing battery power Rapid beeps indicate On ies every 1 2 second the unit will run out of power shortly po conn Battery Overload Occurs when connected equipment exceeds the rating of battery outlets of the unit Turn the UPS off unplug at least one piece of Constant tone a equipment from battery outlets wait 10 seconds reset the circuit breaker and turn the unit on Electrical Wiring Fault This indicates a wiring problem with the AC On Off outlet such as bad ground missing ground or reversed wiring User is advised to disconnect all electrical equipment from the outlet and have an electrician check the outlet to verify proper wiring Utility Failure The frequency is outside of 60Hz 1 for the On 8 beeps LE825DG CP685AVRLCD G CP825AVRLCD G The UPS will not turn on in Line Mode When it beeps the power on LED will flash accordingly DEFINITIONS FOR ILLUMINATED LCD INDICATORS Line mode Select SW UPS Status Display Capacity Display Digital Value Display eee a a a e a Voltage Voltage Time of L
17. ranty Where Can I Get More Information For further information please feel free to contact CyberPower at Cyber Power Systems USA Inc 4241 12 Ave E STE 400 Shakopee MN 55379 call us at 877 297 6937 or send us an e mail message at claims cpsww com CyberPower Systems encourages environmentally sound methods for disposal and recycling of its UPS products Please dispose and or recycle your UPS and batteries in accordance to the local regulations of your state All rights reserved Reproduction without permission is prohibited
18. t Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a dated Proof of Purchase receipt or other proof of the original purchase and provide a description of the defect How Do You Open A Connected Equipment Claim 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions within 10 days of the occurrence 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a dated purchase receipt or other proof of the original purchase and provide a description of the damage to your connected equipment 4 Pack and ship the product to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the Claim Number on the shipping label or include it with the product You must prepay all shipping costs you are responsible for packaging and shipment and you must pay the cost of the repair estimate How Long Do I Have To Make A Claim All claims must b
19. the UPS plugged into an AC outlet at all times 8 To store your UPS for an extended period of time cover it and store with the battery fully charged While in storage recharge the battery every three months to ensure battery life BASIC OPERATION DESCRIPTION ry renee IN OUT Battery and Surge Protected Outlets The unit has four battery powered surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a vacuum cleaner sump pump or other large electrical device into battery and surge protected outlets The power demands of these devices will overload and possibly damage the unit Full Time Surge Protection Outlets The unit has four surge suppression outlets which are always on Power Switch Press the power button to turn the UPS ON or OFF power failure DO NOT plug a laser printer paper shredder copier space heater Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power free of surges and spikes Electrical Wiring Fault Indicator This LED indicator will illuminate to warn the user that a wiring problem exists such as bad ground missing ground or reversed wiring If this is illuminated it is recommended to disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired The unit will not provide surge protection without being plugg
Download Pdf Manuals
Related Search
Related Contents
WALKER - Fitness Boutique Notice - Castorama USER`S MANUAL Manual del usuario User´s handbook Manuel de l Neighborhood Patrol Drone - The University of Texas at Arlington Manuale per la valorizzazione del legname di Acero Fujitsu LIFEBOOK T901 DRL822WA・823WA・ A22WA・A23WA・F23WA Samsung SC8570 Manuel de l'utilisateur Copyright © All rights reserved.