Home

User Manual

image

Contents

1. MARTEL LECTHCNICS CALIBRATORS www martelcorp com e mail sales martelcorp com Tel 603 434 1433 800 821 0023 Fax 603 484 1653 Martel Electronics 3 Corporate Park Drive Derry NH 03038 Rev C 1 13 P N 0219057 RTEL MA CALIBRATORS LEC THCUNICS MECP100 Pneumatic Hand Pump Operating Instructions The Martel MECP100 Hand Pump is designed to be a simple to use pressure and vacuum source for calibrating process control instrumentation Combined with one of our pressure calibrators the MECP100 makes a complete Pressure Vacuum Calibration System Operation The drawing shows the operation of the controls on the MECP100 The pump is designed for use with ambient air only If there is a possibility that contaminants may enter the pump the optional filter Martel P N 54 54067 should be installed at the output fitting CAUTION Do not connect the pump to a pressure source VENT OPEN VENTOPEN PRESSURE VACUUM vent CLOSED VENT CLOSED VERNIER ADJUSTMENT APPROX 25 TURNS 1 8 NPT OUTPUT FITTING PUMP HANDLE Pump Valve Assembly Cleaning Instructions Occasionally the MECP100 may not work properly due to dirt or other contamination of the internal valve assembly Use the following procedure for cleaning the valve assembly If this procedure does not fix the problem a repair kit part number 1010043 may be ordered 1 Using a small screwdriver remove the 2 valve retention caps located on o
2. pposite sides of the pump below the pressure vacuum switch 2 After the caps have been removed gently remove the spring and o ring assembly 3 Set aside the valve assemblies in a safe area and clean out the valve body using a cotton swab soaked in IPA isopropyl alcohol 4 Repeat the process several times using a new cotton swab each time until there is no remaining evidence of contamination or dirt 5 Operate the pump handles several times and recheck for contamination 6 Clean the o ring assembly and the o ring on the retention caps with IPA and inspect the o rings closely for any damage or excessive wear Replacements are included in the repair kit if needed 7 Inspect the springs for wear or loss of tension They should be approximately 8 6 mm long in the relaxed state If shorter they may not provide sufficient sealing tension Replace if needed 8 Once all parts have been cleaned and inspected reinstall the o ring and spring assembly into the valve body 9 Reinstall the retention caps and gently tighten each cap 10 Seal the output port and operate the pump to at least 50 of capacity 11 Release the pressure and repeat several times to ensure that the O rings seat properly WARRANTY Martel Electronics Corporation warrants the MECP100 pneumatic pump against defects in materials and workmanship for a period of twelve 12 months after date of sale An invoice may be required as proof of purchase for warrant
3. y claims Damage due to contamination or other misuse is not covered under this warranty lf any product is to be returned a Return Material Authorization number may be obtained by calling our Customer Service Department toll free at 1 800 821 0023 in the US or Canada or 1 603 434 8179 outside the US Access our RMA Form by using www martelcorp com under Customer Service

Download Pdf Manuals

image

Related Search

Related Contents

Charte EPITECH  ダウンロード - Wacom  the probe`s instruction sheet  取扱説明書 取付・設置説明書  一太郎 9/8 文書 - 島根県建築設計事務所協会  Omnidirectional Condenser Lavalier Microphone U.S. ATR SERIES  ダウンロード - 株式会社 三英社製作所  TE Connectivity LAN Cat.6 S/FTP  Acronis Snap Deploy 3 for PCs, AAS, GOV/EDU, UPG SD 2.0, 50-499u, DEU  

Copyright © All rights reserved.
Failed to retrieve file