Model SC4AJ Conductivity Sensor
Contents
1. Figure 3 4 Wiring between SC4AJ and converter transmitter Terminal Cable conductor number name Terminal name N Contact output 1 NC Z Ol ste c1 I6 15 Soa gt Conductivity Contact output 1 NO O SNO c2 Q 13 Sensor 3 COMA s 108 n Contact output 2 4 s2 12 14 Contact output 3 5 11 9 16 Contact output 4 94 9 O COM2 Ti 2 11 L 8 L T2 O 12 N lt 9 N mA 1 9 gt 9 Analog output T wo Tai Ground to earth I Shield grounding resistance 1000 or less Ground to earth Converter Rear View grounding resistance 1000 or less Note Terminals are M3 5 screws Caution Extra care must be taken the making connection between the SC4AJ sensor and the SC100 converter since the number marker on each sensor cable conductor does not correspond to the one indicated on the converter s terminal block Figure 3 5 Wiring between SC4AJ and SC100 converter Note For details of wiring with SC100 converter refer to IM 12D11A01 01E IM 12D08F03 02E 7th Edition Oct 28 2015 00 4 4 1 4 2 lt 4 Operation gt 4 1 Operation Before operation check following items Check that sensor cable connections are correct Check that there are no problems in flowing the measured solution Check piping connections for measured solution leaks Check that pressure and temperature are within the permitted operating ranges Check that the solution level r
2. 2 5 Drawings and Dimensions Adapter mounting type SC4AJ 0 AD 09 Sensor length 09 9 cm EA e S 9 Unit mm amp e 90 Cable length 3m 5m 10m 15m 20m Pin type Ring type Approx 350 Td 0 Ber E S TA O O 0 rua Unit mm 919 05 a in ing Cable length 3m 5m 10m 15m 20m Eine pe d n ins ae Er asi F I _ L E Approx 350 Q zi GNE K 0 0 Fo ai e Option Adapter mounting type AD PS Stainless Steel IPF PVDF IRS Stainless Steel IRF PVDF A Unit mm A gt P amp lt 3 ANPT Y orR3 A 1 H 4 qu 1 IPS or PF 3 4NPT en IRS or IRF R3 4 Eiza FO6 ai IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 2 Specifications gt 2 6 lt Welding socket type gt SC4AJ 0 SA NN 3 Unit mm o O ring is ela t e ais SE 95 15 L 130 5 J Jj Approx 185 EET S T Pin type Ring type Cable length 3m 5m 10m 15m 20m _ Approx 350 0 E KS lt i SEE gt KO F07 ai e Option Weld
3. 24 Converter and transmitter suitable for SC4AJ FLXA202 FLXA21 2 Wire Liquid Analyzer SC202G SC202SJ Two wire conductivity transmitter SC100 SC402G SC450G Four wire conductivity converter onu Type of terminals Converter SC100 Yes N A N A Transmitter SC202G scaoasy Yes NA s Converter SC402G 3 Yes N A N A Converter SC450G 2 N A Yes Analyzer FLXA202 FLXA21 Yes Yes N A k Applicable when option code TB screw terminal specified for SC202G SC202SJ 2 Both pin and M3 ring can be used for SC450G but M3 ring are recommended 3 SC402G has been terminated Spare parts The following spare parts are necessary in maintaining SC4AJ or changing the installed place Previously procure the parts related to each conductivity sensor type Parts No Description K9670MA O ring set for SA K9670MK Seal rings for SB1 or SB2 K9670MP Seal rings for SC1 K9670MT 3 4 NPT Stainless steel adapter for AD K9670MU 3 4 NPT PVDF Adapter for AD K9670MV R3 4 Stainless steel adapter for AD K9670MW R3 4 PVDF Adapter for AD K9670MD Angled welding socket and mounting nut for SA K9670ME Staight welding socket for SA K9670MB Angled welding socket for SA K9670MC Straight welding socket for SA K9670ML Welding clamp 1 or 1 5 inch for SB K9670MQ Welding clamp 2 inch for SC IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 2 Specifications gt 2 5
4. C For holder see Figure 2 1 Sterilization for electrode 135 C 275 F within 30 minutes in Steam Sterilization Pressure range For electrode 0 to 1 MPa For holder see Figure 2 1 MPa 1 2 1 0 0 8 0 6 0 4 0 2 0 10 20 30 40 50 60 70 80 100 120 140 C F03 ai Figure 2 1 The range of tolerance of holders option PS PF RS RF SA1 SA2 SB1 SB2 SC1 for temperature and pressure IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 2 Specifications gt 2 2 Sample solution condition Although flow rate is not limited in measurement air bubbles should not be mixed in the measured solutions to obtain correct measured values Temperature sensor Materials Body amp Electrode Isolator Mounting adapter Pt1000 Stainless steel 316 SS for all Fitting type or Titanium only for adapter mounting type AD Fluoro rubber FKM O ring PEEK Plyvinylidene difluoride for PF and RF or Stainless steel 316 SS Stainless steel 316L SS Weight Sensors Adapter mounting type SC4AJ S AD 09 002 05 approx 450 g Adapter mounting type SC4AJ S AD 15 002 05 approx 520 g Welding socket type SC4AJ S SA NN 002 05 approx 670 g 1 or 1 5 inch welding clamp type SC4AJ S SB NN 002 05 approx 550 g 2 inch welding clamp type SC4AJ S SC NN 002 05 approx 670 g Note There are weight differences among SC4AJ sensors In order to know the more accurate weight of each type of sensors please calculate it
5. Option code PS RS material stainless steel and PF RF material PVDF are for the adapters special for the Adapter Mounting Type of the SC4AJ As for their dimensions refer to section 2 5 Mounting is done by the combination of the sensor with the adapter Mount the sensor by the correct insertion order of adapter parts according to Figure 3 1 Note Screwing the nut by the incorrect order of the parts can cause trouble of the mounting system and sealing defective Tighten the nut with a torque of approx 190 N m 19 kgf m This corresponds approximately to first tightening with the fingers then using a spanner or the like to tighten by one and a quarter turns Adapter PS PF IRS RF F3 1 ai Figure 3 1 Mounted sensor SC4AJ AD IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 3 Mounting and Wiring gt 3 2 3 1 2 Welding socket type SA Option code SA1 and SA2 are for the adapters special for the Welding Socket Type of the SCAAJ As for their dimensions refer to section 2 5 As shown in Figure 3 2 weld the welding socket to a pipe in which a process liquid flows After inserting the SC4AJ sensor into the welding socket screw the nut with your hand Note Before inserting the sensor check the following matter The socket is cooled to room temperature after welding is done The O ring is attached to the sensor O ring Welding socket F3 2 ai Figure 3 2 Mounting sensor SC4AJ SA I
6. Oct 28 2015 00 All Rights Reserved Copyright 2006 Yokogawa Electric Corporation lt Introduction gt Il For the safe use of this equipment B Safety Protection and Modification of the Product In order to protect the system controlled by the product and the product itself and ensure safe operation observe the safety precautions described in this user s manual We assume no liability for safety if users fail to observe these instructions when operating the product If this instrument is used in a manner not specified in this user s manual the protection provided by this instrument may be impaired Be sure to use the spare parts approved by Yokogawa Electric Corporation hereafter simply referred to as YOKOGAWA when replacing parts or consumables Modification of the product is strictly prohibited The following symbols are used in the product and user s manual to indicate that there are precautions for safety B Notes on Handling User s Manuals Please hand over the user s manuals to your end users so that they can keep the user s manuals on hand for convenient reference Please read the information thoroughly before using the product The purpose of these user s manuals is not to warrant that the product is well suited to any particular purpose but rather to describe the functional details of the product No part of the user s manuals may be transferred or reproduced without prior written consent from YOKOGAWA
7. T 250 8 gt F12 ai IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 3 Mounting and Wiring gt 3 1 3 Mounting and Wiring 3 1 Mounting Before mounting an electrode in a process plant environment the following points should be considered The electrode must be mounted in the process in such a way that the flow through it represents the true composition of the liquid The flow through the cell should be uninterrupted and the cell should not be mounted at a dead angle Acell must be immersed in the process liquid to a level above the outlet to ensure an uninterrupted liquid path between the electrodes The sensor should be mounted in such a way to allow safe and easy removal for maintenance and to release the process liquid pressure for the removal Check the process pressure for mounting place is below the pressure range of the SC4AJ and its adapter Donotsubmerge the sensor itself in process water as the seams between the mold and the metal of the sensor are not waterproof A IMPORTANT When ultra pure water flows through plastic pipe electrostatic charge may be produced When the sensor is installed on this plastic pipe the electrostatic charge goes through the sensor and into a converter circuit through terminals on the converter which is connected to the sensor This electrostatic charge will discharge and damage electronic parts on the converter circuit 3 1 1 Adapter mounting type AD
8. and Suffix Codes 22 422u44420244000nn0nnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnn 2 3 2 3 Converter and transmitter suitable for SC4AJ eese 2 4 2 4 Spare parts ER E 2 4 2 5 Drawings and Dimensions eene nnne nnne nnns 2 5 3 Leg nep nV pe 3 1 3 1 MOUNTING iii 3 1 3 1 1 Adapter mounting type AD ssseeeenn 3 1 3 1 2 Welding socket type ESA seen 3 2 3 1 3 Welding clamp type SB SC seen 3 3 3 2 LINIDDmE 3 4 4 Operati M 4 1 4 1 Set of cell constant value eese nennen 4 1 4 2 Calibration with a solution of known conductivity s 4 1 5 o A 5 1 5 1 Cleaning of the cell eerte entente nnne nnnc 5 1 5 2 Checking on the cell nennen aaa 5 1 Customer Maintenance Parts List CMPL 12D08F03 02E Revision Information sss sssssseessssees esse esse eee eee nenen enen nenen enen i vii IM 12D08F03 02E 7th Edition Oct 28 2015 00 1 lt 1 General gt 1 1 General The SC4AJ is developed with the intention for the low conductivity applications found in the semiconductor power water and pharmaceutical industries The SC4AJ is in a convenient compact style The cell has been ma
9. m pin terminals U 5m pin terminals E E 10 m pin terminals ose 15 m pin terminals 3 20 m pin terminals 3 3 m M4 ring terminals 5 5 m M4 ring terminals 5 10 m M4 ring terminals 5 15 m M4 ring terminals 5 20 m M4 ring terminals 5 3 m M3 ring terminals 6 ER 5 m M3 ring terminals 6 10 m M3 ring terminals 6 ES 15m M3 ring terminals 6 m 20 m M3 ring terminals 6 Temperature sensor J TA b Pt1000 Option For AD only 3 4NPT adapter 316 SS 3 4NPT adapter PVDF R3 4 adapter 316 SS R3 4 adapter PVDF Straight welding socket 316L SS Angled welding socket 15 316L SS Welding clamp 1 inch 316L SS Welding clamp 1 5 inch 316L SS Welding clamp 2 inch 316L SS Oil prohibited use 4 For SA only For SB only For SC only Oil prohibit 4 When you select fitting type SA place an order on the SC4AJ with option code SA1 or SA2 2 When you select fitting type SB place an order on the SC4AJ with option code SB1 or SB2 including seal ring When you select fitting type SC place an order on the SC4AJ with option code SC1 including seal ring 3 Impossible use for the SC400G 4 Washing treatment of wet part with alcohol 5 Used for connection to FLXA202 FLXA21 6 Used for connection to SC450G SC202u TB IM 12D08F03 02E 7th Edition Oct 28 2015 00 2 Specifications gt 2 4 2 3
10. 21 model and suffix code below is available FLXA21 D o D EA C 1 0 A N LA N NN can be any value o must be NN or C1 Any option code is available For SC202S model and suffix code below is available SC202S A E There are no SC202S models that meet the Korean explosion proof standards Any option code is available Upper limit of process temperature on the SC4AJ Transmitter used in combination FLXA21 SC202S 60 C Ai Care about upper limit 100 C of temperature class T5 should be taken Other warnings are provided in the following IN WARNING Handling precautions 1 Potential electrostatic charging hazard Electrostatic charge may cause an explosion hazard Avoid any actions that cause the generation of electrostatic charge e g rubbing with a dry cloth 2 IEC60079 14 Electrical installations in hazardous areas requires a label indicating simple apparatus stick this label to this sensor if necessary IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt Introduction gt iv B Symbol Marks Throughout this user s manual you will find several different types of symbols are used to identify different sections of text This section describes these icons NWARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury AN CAUTION Indicates a potentially hazardous situation which if not avoided may result in mino
11. M 12D08F03 02E 7th Edition Oct 28 2015 00 lt 3 Mounting and Wiring gt 3 3 3 1 3 Welding clamp type SB SC Option code SB1 and SB2 are for the adapters special forthe Welding Socket Type ofthe SC4AJ SB and SC1 is for the SC4AJ SC As for their dimensions refer to section 2 5 As shown in Figure 3 3 weld the flange to a pipe in which a process liquid flows Insert the SC4AJ sensor with the seal ring into the flange Fix the sensor with the clamp Clamp Welding clamp Flange Figure 3 3 Mounted sensor SC4AJ SB SC IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 3 Mounting and Wiring gt 3 4 3 2 Wiring The conductivity sensor can be used with two wire Liduid Analyzer FLXA202 FLXA21 or two wire conductivity transmitter SC202 or four wire conductivity converter SC100 SC402G SC4506 To connect the sensor and transmitter converter simply match the terminal numbers in the transmitter converter with the identification numbers on the cable ends White 11 7 Temperature 12 13 Yellow 14 Electrode F3 4 ai Applicable Converter Transmitter SC402G SC450G SC202 FLXA202 FLXA21
12. User s Manual Model SC4AJ Conductivity Sensor IM 12D08F03 02E vigilantplant YOKOGAWA 4 IM 12D08F03 02E A 7th Editi Yokogawa Electric Corporation ae lt Introduction gt I Introduction Thank you for purchasing our inductive conductivity measurement system This manual describes the method of installing for the SC4AJ To ensure that this measurement system can be operated safely and also exhibit its full performance be sure to read this manual before use This manual does not describe the units in Table shown below which are the component units ofthe conductivity measuring system Each of these units comes with an instruction manual so read the applicable manuals for details of the units concerned O Mame HT SC202G SC202SJ 2 Wire Conductivity Transmitter IM 12D08B02 01E FLXA202 FLXA21 2 Wire Liquid Analyzer IM 12A01A02 01E SC450G 4 Wire Conductivity Converter IM 12D08N05 01E Upon delivery unpack the instrument carefully and inspect it to ensure that it was not damaged during shipment If damage is found retain the original packing materials including the outer box and then immediately notify the carrier and the relevant YOKOGAWA sales office Make sure the model code on the label affixed to the cable agrees with your order For the meaning of the model code refer to the Model and Suffix code table Section 2 2 Media No IM 12D08F03 02E 7th Edition Oct 2015 YK IM 12DO8F03 02E 7th Edition
13. YOKOGAWA reserves the right to make improvements in the user s manuals and product at any time without notice or obligation If you have any questions or you find mistakes or omissions in the user s manuals please contact our sales representative or your local distributor B Warning and Disclaimer The product is provided on an as is basis YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance B Compliance with the simple apparatus requirements SC4AJ meet the simple apparatus requirements defined in the following standards Note TIIS certified types cannot be connected Use the sensors under the conditions of use required by the standards Applicable standards ANSI ISA 60079 11 2014 ANSI ISA 60079 0 2009 CAN CSA C22 2 NO 60079 11 14 CAN CSA C22 2 NO 60079 0 11 HIFA epyrebdele TA V mo GB 3836 4 2010 IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt Introduction gt I Conditions of use 1 Use in combination with an internally isolated transmitter or use with a transmitter in combination with isolated barrier The FLXA21 is internally isolated 2 Upper limit of the process temperature The upper limit of process temperature is indicated below when the sensor is used in combination with a YOKOGAWA transmitter For FLXA
14. anual No of FLXA21 added P2 FLXA21 added P4 Some of description for MS code modified M4 ring terminal for FLXA21 added P5 FLXA21 added to combination of sensor and converters P6 to P9 Some of cable label description on drawings and dimensions modified Mar 2010 3rd Edition Illustrations of each figure replaced more clearly drawings no contents changed Jan 2008 2nd Edition Ring terminals added for SC450G converter May 2006 1st Edition Newly published W f you want to have more information about Yokogawa products you can visit Yokogawa s home page at the following web site Home page http www yokogawa com an IM 12D08F03 02E 7th Edition Oct 28 2015 00
15. de available with either a titanium or stainless steel electrode The electrode is the 2 electrode system with cell constants of 0 02 cm or 0 10 cm and with a fixed cable 3 to 20 meters in length In response to customer demands a variety of fittings for SC4AJ are also available IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 2 Specifications gt 2 1 2 Specifications 2 1 Standard Specifications Cable with pin terminals applicable to SC100 FLXA202 FLXA21 SC202G and SC202SJ Cable with M3 ring terminals applicable to SC450G SC2020 TB Cable with M4 ring terminals applicable to FLXA202 FLXA21 Object of measurement Conductivity of solutions Measuring principle Two electrode system Cell constant 0 02 cm 0 1 cm Measuring range For a cell constant 0 02 cm In case of the combination with the SC450G FLXA202 FLXA21 SC202G or SC202SJ 0 0 5 uS cm to 0 200 uS cm In case ofthe combination with the SC100 0 100 uS cm to 0 1 mS cm Material Titanium only SC100 can not use with SC4AJ sensor made of Stainless Steel which cell constant is 0 02 cm 1 For a cell constant 0 1 cm In case of the combination with the SC450G FLXA202 FLXA21 SC202G or SC202SJ 0 5 uS cm to 1 mS cm In case of the combination with the SC100 0 500 uS cm to 0 5 mS cm Material Titanium In case of the combination with the SC100 0 500 uS cm to 1 mS cm Material Stainless Steel Temperature Range For electrode 0 to 110
16. eaches the measured solution outlet when the flow of measured solution is started Set of cell constant value Enter the factory calibrated cell constant value for the converter or the transmitter connected to the SC4AJ The factory calibrated cell constant value is labelled on the cable As for the procedure of the entry refer to Instruction Manual of the converter or the transmitter Calibration with a solution of known conductivity The cell constant is determined in laboratory conditions It is possible that slight variations in the cell constant may occur dependant on the installation This possible error can be corrected by recalibrating with a solution of known conductivity value NOTE The specific conductivity value of the solution of known value must be near the value of the liquid to be measured Specific conductivity is highly temperature dependent therefore in the above calibration procedure the temperature of the cell and the liquid should be allowed to equalize and should be accurately measured with a calibrated thermometer IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 5 Maintenance gt 5 1 5 Maintenance If the cell becomes fouled an insulating layer may be formed on the electrodes As the result an apparent increase in cell constant may occur giving a measuring error Check and maintain the sensor in case of an error occurrence 5 1 Cleaning of the cell A For lime hydroxides etc 5 to 10 solut
17. from following information The cable weighs 75 g m The SC4AJ with 0 02 cm cell constant is 15 g heavier than the SC4AJ with 0 1 cm cell constant 314L SS electrode is 40 g heavier than Titanium electrode Adapters 3 ANPT stainless steel adapter PS approx 110 g R3 4 stainless steel adapter RS approx 110 g 3 ANPT PVDF adapter PF approx 35g R3 4 PVDF adapter RF approx 35 g Straight welding socket SA1 approx 300 g Angle welding socket 15 SA2 approx 320 g Welding clamp 1 inch SB1 approx 330 g Welding clamp 1 5 inch SB2 approx 305 g Welding clamp 2 inch SC1 approx 350 g N NOTE Do not submerge the sensor itself in process water as the seams between the mold and the metal of the sensor are not waterproof IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt 2 Specifications gt 2 2 Model and Suffix Codes Suffix Code Option Code Description TT TEST Conductivity sensor Material T 0 qe Titanium Only for AD E 316L SS Fitting type JAD qpeeeeees eHHM Adapter mounting type Renean Welding socket type 1 MEM 1 or 1 5 inch welding clamp type 2 nn 2 inch welding clamp type 2 Sensorlengh 09 eee 9 cm Code for AD 15 cm Code for AD pri fixed length Code for SA SB SC Cell constant 002Q j 0 02 cm ee Ns 0 1cm Cable length 3
18. ing socket type SA Unit mm Straight welding socket SA1 Angled welding socket SA2 51 8 5 Socket 55 thickness Dog Y 042 FO8 ai IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt Welding clamp type gt SC4AJ 0 SB NN oO 2 gt o9 2 2 2 HARE 70 16 35 L 89 7 J Approx 150 le Cable length 3m 5m 10m 15m 20m _ gt lt 2 Specifications gt Unit mm zem Pin type Ring type gt 0 Approx 350 ED V 0 amp H 2 30 8 0 F09 ai e Option Welding clamp type SB Unit mm Welding clamp 1 inch SB1 Welding clamp 1 5 inch SB2 S 2 E 3 E N U N g 025 4 038 1 F10 ai Sensor SC4AJ 0 SC NN Unit mm Y 2 BIE WS amp E 80 116 35 115 7 L Approx 170 J m l Cable length 3m 5m 10m 15m 20m lt a Approx 350 gt 0 0 lt A AEG gt KO SOKO Fila e Option Welding clamp type SC Unit mm Welding clamp 2 inch SC1 A N T
19. ion of hydrochloric acid is recommended B For organic foul oil fats etc they can be removed with ethyl alcohol or acetone C For algae bacteria or moulds use a chlorinated solution domestic bleach D For normal applications hot water with domestic washing up liquid will be effective NWARNING Never use hydrochloric acid and domestic bleach simultaneously The liberation of the very poisonous gas chlorine will result 5 2 Checking on the cell After cleaning the sensor check the condition of it with the eye Measure the resistances of the sensor for the following procedure A Fully dry the sensor specially the cell B Measure the resistivity between cable terminals C The combination of the terminals and standard resistance are as follows Combination of Terminals Standard Resistance 11 and 12 1000 to 1137 O room temperature 11 and 13 12 and 13 12 and 14 12 and 15 more than 100 MO 13 and 14 15 and 16 less than 10 O IM 12D08F03 02E 7th Edition Oct 28 2015 00 Customer Maintenance Parts List Model SC4AJ Conductivity Sensor Adapter Welding Socket SCAAJ L1 AD 09 SCAAJ LI SA NN Option code SA1 ISA2 pm PX X 5 3 6 III Welding Clamp SCAAJ LI SB NN SB1 SB2 9 8 x 7 E lt ZZ po SCAAJ LI SB NN SC1 12 11 Z z E zj 13 All Rights Reserved Copyrigh
20. r or moderate injury It may also be used to alert against unsafe practices A IMPORTANT Indicates that operating the hardware or software in this manner may damage it or lead to system failure KUN NOTE Draws attention to information essential for understanding the operation and features IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt Introduction gt v After sales Warranty B Do not modify the product B During the warranty period for repair under warranty consult the local sales representative or service office Yokogawa will replace or repair any damaged parts Before consulting for repair under warranty provide us with the model name and serial number and a description of the problem Any diagrams or data explaining the problem would also be appreciated e If we replace the product with a new one we won t provide you with a repair report Yokogawa warrants the product for the period stated in the pre purchase quotation Yokogawa shall conduct defined warranty service based on its standard When the customer site is located outside of the service area a fee for dispatching the maintenance engineer will be charged to the customer B n the following cases customer will be charged repair fee regardless of warranty period Failure of components which are out of scope of warranty stated in instruction manual Failure caused by usage of software hardware or auxiliary equipment which Yokogawa Elect
21. ric did not supply Failure due to improper or insufficient maintenance by user Failure due to modification misuse or outside of specifications operation which Yokogawa does not authorize Failure due to power supply voltage frequency being outside specifications or abnormal Failure caused by any usage out of scope of recommended usage Any damage from fire earthquake storms and floods lightning disturbances riots warfare radiation and other natural changes B Yokogawa does not warrant conformance with the specific application at the user site Yokogawa will not bear direct indirect responsibility for damage due to a specific application B Yokogawa Electric will not bear responsibility when the user configures the product into systems or resells the product B Maintenance service and supplying repair parts will be covered for five years after the production ends For repair for this product please contact the nearest sales office described in this instruction manual IM 12D08F03 02E 7th Edition Oct 28 2015 00 lt CONTENTS gt Model SC4AJ Conductivity Sensor IM 12D08F03 02E 7th Edition CONTENTS 0 7 m i For the safe use of this equipment eese ii 6 After sales Warranty a eee ee neee v 1 t c ae euere 1 1 2 SPECHICAUONS een 2 1 2 1 Standard Specifications ussu000snnnannnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnn 2 1 2 2 Model
22. t O 2006 Yokogawa Electric Corporation CMPL 12D08F03 02E YOKOGAWA 4 Subject to change without notice 1st Edition May 2006 YK Yokogawa Electric Corporation AO K 00 10 11 12 13 CMPL 12D08F03 02bE Part No Qty K9670MU K9670MT K9670MW K9670MV K9670ME K9670MF K9670MC K9670MD K9670MB K9670MA K9670ML K9670MK K9670MM K9670MN 1 1 1 1 K9670MQ 1 K9670MP K9670MR 1 Description Adapter for suffix code AD 3 ANPT PVDF adapter 3 4NPT Stainless steel adapter R3 4 PVDF adapter R3 4 Stainless steel adapter Straight welding socket and mounting nut for SA1 Nut Socket Angled welding socket and mounting nut for SA2 Socket O ring Welding clamp for SB1 SB2 Seal ring for SB1 SB2 Welding socket For SB1 For SB2 Welding clamp for SC1 Seal ring for SC1 Welding socket for SC1 1st Edition May 2006 YK Revision Information e Title Model SC4AJ Conductivity Sensor O Manual No IM 12D08F03 02bE Oct 2015 7th Edition Added FLXA202 P i P2 1 P2 3 P2 4 P3 4 Unification of the material name P2 1 P2 2 Apr 2015 6th Edition P ii to iii Added to m Compliance with the simple apparatus requirements P3 1 Symbol Marks of IMPORTANT added to 3 1 Mounting Jul 2013 5th Edition P 2 2 Some revision of material option code of PS RS changed P 2 3 Some revision of option code material of PS RS changed to SUS316 Jun 2011 4th Edition Pi M