Home
Chili User Manual
Contents
1. SET UP CONTINUED To Cool Press the COOLER button to select your desired temperature The digital reading on the display will blink 3 times to indicate the setting was accepted The Cube will start to work and display the actual temperature To Warm Press the WARMER button to select your desired temperature The digital reading on the display will blink 3 times to indicate the setting was accepted The Cube will start to work and display the actual temperature Note The temperature adjustment steps can be completed with the remote control or on the Cube display panel Using the Remote Remote Pairing e Plug in the Cube e Touch the ON OFF button on the Cube display panel and hold for 5 seconds The Cube will sound a long beep and the display will show a blinking 888 e Turn the remote control ON The Cube will sound a short beep and display the actual temperature Batti Lid Switching Between F and C e Turn OFF the remote control e Turn ON the Cube on the display panel e Press the ON OFF button the remote control and hold for 2 seconds pg 13 SET UP CONTINUED Turning the Cube Off Press the ON OFF button on the Cube or remote The Cube will beep then the pump and fan will stop running The pump and or fan may continue to run for a short time once the unit has been turned off If the unit is not to be used for a 24 hour period unplug from the wall Adjusting the Temperature
2. SET UP INSTRUCTIONS Mattress Waterproof Mattress Protector ChiliPad Fitted Sheet Then Comforter Completely unfold the ChiliPad and place it flat on top of your waterproof mattress protector which is on top of your mattress see set up order above The tail pipe tube that connects the pad to the Cube can be at the head or the foot of the bed Position the elastic strap underneath the mattress to keep the ChiliPad in place Place your fitted sheet directly over the ChiliPad For optimal performance a dense blanket or comforter should be placed over the body when the ChiliPad Cube is in use to provide the needed insulation to keep the bedding surface cool or warm Connecting ChiliPad tubing to the Cube Place your Chili Technology Cube on a hard flat surface near your bed Remember that spacing of at least 24 inches 60cm should be left on all sides and above the unit this is critical to optimal performance of the system Connect the tubing from your ChiliPad product to the Cube as shown below You must hear a click sound to ensure proper connection _ Note If you need to disconnect the tubing press the tube disconnect button located on _ the bottom of the Cube Please note that a few the tubing drops of water may result when disconnecting pg 11 SET UP CONTINUED Connecting the Power Plug the power cord into an outlet Note This device has a grounded plug To reduce
3. of it flailing in the spin cycle and damaging the connector e Use only GENTLE DELICATE washing cycle and feel free to add a little OxyClean or similar cleaner that includes peroxide in the active ingredients e Dry on DELICATE AIR ONLY cycle Use NO HEAT setting or air dry pg 16 MAINTENANCE CONTINUED Every three months Deep Cleaning Empty all water from control unit s Fill unit s with 4 cup 4 oz 118 ml of hydrogen peroxide Completely fill unit s with distilled water Run unit s on HI setting with CAP OFF for 6 8 hours Place unit s higher than pad to ensure water does not spill out of the top of the unit s After heating cycle dump water hydrogem peroxide mixture and refill with distilled water o If cleaning has not been performed before or has been longer than 3 months repeating this process may further improve performance Once this cleaning process is complete run system as normal including the normal hydrogem peroxide additive pg 17 STORAGE Disconnect the Tubing If you need to disconnect the tubing from the Cube e Press the tube disconnect button located on the bottom of the Cube refer to page 9 e Remove the tube from the connector Note Removing the tube without pressing the tube disconnect button located on the bottom of the unit can damage the connectors How to remove water from the ChiliPad If the Cube will not be in use for an extended period you should purge
4. the risk of electric shock this plug is intended to fit in a grounded outlet only one way If it does not fit contact a qualified electrician Do not modify the plug in any way Filling the Cube with Water Distilled water is recommended e You will need to fill the water reservoir before the first use e The water reservoir is located on the top center of the Cube e Unscrew and remove the cap then add water until the reservoir is full approximately 140z 390ml Note Have additional water ready to pour after Cube is started to fill the tubing in the Pad e Turn the Cube on by touching the ON OFF button e The Cube will beep and the pump will begin to run This is where additional water will be needed as the water in the reservoir will be pumped into the Pad e As water starts circulating through the tubing in your Chili product Continue to slowly fill the reservoir until the water level reaches the bottom of the cap thread lines this amount will vary depending on the size of your pad o Use clean water Distilled water is recommended o Donotimmerse the Cube in water to fill o Be careful not to spill water on the Cube o Refill the water reservoir when the water level gets low or the Low Water light comes on The Cube will not operate when the water level in the reservoir is too low or empty Turning the Cube On Press the ON OFF button on the Cube or remote The Cube will beep and the pump will begin to run pg 12
5. Chi liTechnology USER MANUAL ChiliPAD ili cube I q q Single Zone Dual Zone Use this guide to describe use and set up as well as offer trouble shooting tips with your Chili Product If the issue still occurs please contact customer Service at customerservice chilitechnology com or call 1 877 235 6271 Note Please read these instructions carefully before use pg 2 Table of Contents Introduction Page 5 Before you get started Page 6 Safety instructions Page 7 8 Contents Page 9 Using the Cube Page 10 Set up instructions Page 11 15 Maintenance Page 16 17 Storage Page 18 Technical Parameters Page 19 Troubleshooting Page 20 pg 3 Chili Technology welcomes you to a new sleep experience We are dedicated to advances in sleep engineering Our goal is to give you a perfect night s sleep by enabling you to personalize your sleep environment As you set up your ChiliPad Cube we hope you enjoy your experience and find your own sleep temperature and individual degree of comfort pg 4 INTRODUCTION The Chili Technology Cube is a revolutionary cooling and warming system that regulates the surface temperature of your mattress fora perfect night s sleep Chili Technology can be used 12 months out of the year and is designed to improve your sleep night after night The silicone circulation tubes run conditioned water throughout the mattress surface
6. The Cube must be turned on to adjust the temperature The Cube cools or warms water in individual degree increments between 552 F 132 C and 1102 F 432 C The Cube will cool below 552 F 132 C on the cool LO setting and above 1102 F 432 C on the cozy HI setting Once desired temperature is set water circulates through the pad generally achieving your desired temperature In some cases the maximum and minimum temperatures will not be reached due to some of the following factors ambient air temperature humidity individual body heat insulation allowing the unit sufficient air flow and heat load on top of the Chili product For maximum performance it is recommended that each individual have his or her own Cube Maximum Temperature Change Condensation may occur on the tubing and or pad based on ambient air temperature humidity and individual body heat To address this adjust the air temperature of the room lower and or the Cube temperature higher Please see the troubleshooting guide for information on how to solve this issue or refer to the Chili Guru Videos on our web site www chilitechnology com for troubleshooting or further assistance Operational Tips Insure there is ample space around the Cube for ventilation The Cube uses fresh air to cool the electronics so sufficient fresh air is necessary for optimal performance and long life of your system Clearance of 24 inches 60cm on all sides and above is recommen
7. cated this situation persists note error code has occurred F1 F2 F3 unplug Cube and contact F4 F5 customer service Error code displayed on Cube display panel pg 20
8. ded for optimal performance and longevity The Cube can never be operated under the bed Frequently inspect the connection tubes to insure there are no kinks or restrictions that may prevent free flow of the water through your system Use the following link to access cleaning tips pg 14 SET UP CONTINUED FCC Compliance The remote device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must not accept any interference received including interference that may cause undesired operation Warning Changes or modifications to this unit will void the manufactures warranty Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference ina residential installation This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with these instructions it may cause harmful interference to radio communications and there is no guarantee that interference will not occur in a particular situation If this equipment does cause interference with TV or radio reception which can be determined by turning the device on and off the user is encouraged to try to correct the interference by one or more of the following measur
9. duct If the issue still occurs please contact customer service at customerservice chilitechnology com or call 1 877 235 6271 pg 19 TROUBLESHOOTING Don t forget to visit our ChiliGuru help section for more helpful tips and tricks Visit www chilitechnology com and click the FAQ tab Check to see if the outlet has power If the electrical cord is No Power damaged unplug and immediately call customer service Be sure power cord is securely Does not turn on Disconnected from power iiseried ite Cube power source socket n Add water by following the Set Reservoir is out of water Up Instructions in this manual Remote is not working Replace the batteries Add water by following the Set Reservoir is low on water Up instructions in this manual Poor Make sure the Chili Product is cooling warming Tubing is kinked flat on the bed and there are no effect kinks in the tubing Use a covering like a blanket or No covering over your comforter over your body to body when you sleep help insulate your sleeping environment 20 F 10 C differencein Adjust the Cube setting up 2 Condensation air temperature and the 5 F 1 3 C until there is no Cube temperature setting longer a condensation build up Unit is equipped with Turn off and unplug unit Wait several automatic shut off 15 minutes turn unit on and functions to protect the reset preferred sleep system an error code temperature setting If issue indi
10. es e Reorient or relocate the receiving antenna e Increase the separation between the two devices e Plug the two devices into different wall outlets e Consult Chili Technology Customer Service for assistance pg 15 MAINTENANCE Once a month maintenance Water Maintenance e Distilled water is recommended e One time per month add cup 2 oz 59 ml of hydrogen peroxide into the water reservoir to keep the circulation system clean Procedure Set temperature to 90 F 32 C Remove the water reservoir cap and add the hydrogen peroxide LEAVE THE WATER RESERVOIR CAP OFF The hydrogen peroxide will react with any dirt or other foreign particles to clean the system Once the reaction has stopped bubbles no longer form or 20 minutes has passed replace the cap reset the Cube to your desired sleep temperature and enjoy Cleaning the Cube e With the Cube turned off and unplugged use a clean damp cloth to clean the outside of the Cube and remote control Use only mild soap if necessary Be careful not to get water inside of the Cube e Use can of compressed air or similar to blow through the intake exhaust vents on all sides removing dust and debris e Never submerge or get water inside the Cube Washing the Pad as needed e The Pad is washable in a frontloading washing machine COLD WATER ONLY e Secure the tail pipe part that runs from the pad to the Cube with a thick rubber band or other means to minimize risk
11. istance for electric current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded Do not modify the plug provided with the product if it will not fit the outlet have a proper outlet installed by a qualified electrician This product has a grounding plug that looks like the plug illustrated in sketch A Make sure that the product is connected to an outlet having the same configuration as the plug No adapter should be used with the product pg 7 IMPORTANT SAFETY INSTRUCTIONS Use of electrical appliances requires the following precautions to reduce the risk of fire electric shock and injury 1 Read all instructions before using this cooling and warming bed system A 2 WARNING Do not use this cooling and warming bed system with infants individuals with diminished capacity or anyone insensitive to heat such as a person with poor blood circulation unless under supervision A 3 WARNING Do not use this cooling and warming bed system with any other heated blanket comforter quilt sheet mat
12. o not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the cooling and warming device 16 Never operate the cooling and warming device with the air openings blocked Keep the air opening free from any debris 17 A cooling and warming system has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 18 Do not use attachments not recommended by the manufacturer 19 Do not operate where aerosol spray products are being used or where oxygen is being administered 20 Do not open or break the housing on this cooling and warming device as this will invalidate your warranty 21 WARNING Risk of Electric Shock Connect this furnishing to a properly grounded outlet only See Grounding Instructions 22 Use this product only for its intended use as described in these instructions within this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons pg 8 CONTENTS The Cube One Cube per Zone The Pad Pad will fit snuggly over your mattress amp supportive straps will keep the pad in place The Remote One Remote per Zone pg 9 USING THE CUBE Display Mute F C Low water ON OFF Indicator Control Panel Air Intake Vent Tubing Connection Power Cord Back pg 10
13. ose between the Cube and the ChiliPad 5 Be careful with sharp objects near the ChiliPad to avoid punctures of the circulation tubing 6 Children some individuals with disabilities or individuals with cognitive impairments must be under adult supervision when using the ChiliPad Cube 7 The Cube is to be used on a standard AC power circuit of the proper voltage 8 Turn OFF or unplug when not in use 9 The Cube is programmed to turn off automatically after 10 hours of continual use The Cube can be turned on again manually after it automatically turns itself off 10 Overheating may result from using the Cube in any manner other than as described in this manual 11 Wrapping the power cord around the Cube may damage the cord Please wrap the power cord loosely during storage 12 If the Cube is not working properly unplug discontinue use and immediately contact Chili Technology Customer Service at customerservice chilitechnology com or 877 235 6271 pg 6 Save these instructions Sketch A nnn FE erini a i 4 E j _ d w g i Bs soreness oe F amp Cy ar UK type G Switzerland type J India type D es i Pas pee Ae ee i 4 8 80 I N i O o l i eens 4 is Australia China type israel type H USA type B i a C grounding pins or hole GROUNDING INSTRUCTIONS This product must be grounded If it should malfunction or breakdown grounding provides a path of least res
14. the water from both the Cube and the Pad e To drain the ChiliPad you would use water drainage adapter To obtain one of these please contact customerservice chilitechnology com or call 1 877 235 6271 e To drain the water from the Cube after unplugging and disconnecting the pad take the cube to a sink or bucket remove the water reservoir cap and drain the water pour away from the display panel i e drain from opposite side of the connectors in order to avoid getting any water on the display panel Storing the Cube e Disconnect the connection tubing from the Cube using the disconnect button on the bottom on the Cube refer to page 12 e Drain any remaining water from the unit by removing the water reservoir cap Gently tilt the Cube so the water drains through the reservoir opening Replace the cap e Wrapping the power cord around the Cube may damage the cord Please wrap the power cord loosely during storage e Remove the batteries from the remote control e Store the Cube and remote control in a clean dry place Please visit our Chili Guru s for additional assistance with routine cleaning and maintenance http www chilitechnology com chili guru help videos pg 18 TECHNICAL PARAMETERS Rated Voltage AC 90 230V Rated Frequency 50Hz 60Hz Lower than 55 F 13 C and Higher than 110 F 43 C Rated Power Power 170W Rated Amperage Control Use this guide to address problems with your Chili Pro
15. to maintain your ideal sleep temperature The control unit for your ChiliPad is referred to in this manual as the Cube The Chili Technology cooling and warming system allows adjustments to be made to your bedding surface The Cube cools or warms water to your set temperature and circulates it through the pad generally achieving temperatures well below a cool 552 F 132 C and easily above avery warm 1102 F 432 C The Cube motor 45 dB and only uses 170 Watts of power Use the ChiliPad Cube to set the temperature of your bed instead of heating or cooling your entire house while you sleep Keeping your home thermostat at a more moderate temperature translates into real energy savings that allow your Chili product to pay for itself pg 5 BEFORE YOU GET STARTED 1 Keep the Cube away from areas that might become damp or wet such as an open window The Cube should be placed on a dry firm floor ina well ventilated area free from surrounding fabric Spacing of at least 24 inches 60cm should be left on all sides and top of the unit Never operate the Cube under a bed 2 Never turn the cube on before the connection hose coming from the pad has been connected to the Cube 3 The Cube must have water added before initial use You will need to add additional water on initial set up as the mattress fills with water Refer to the Set Up section of this manual for full instructions 4 Avoid any bends or kinks of the h
16. tress pad mattress foot warmer throw blanket or similar cooling or heating bedding 4 A WARNING To prevent a possible fire do not block air intakes or exhaust in any manner Do not use the electrical device on soft surfaces like a bed where openings may become blocked Do not operate under the bed 5 Use close supervision when this cooling and warming bed system is being used by and around children or individuals with cognitive impairments 6 Donotimmerse the cooling and heating devise in water 7 Do not place power cord between mattress and foundation Do not run under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route power cord under furniture or appliances Arrange power cord away from traffic areas and where it could be tripped over Do not allow the cords to be pinched 8 Do not operate this product in the event that the power cord or plug becomes damaged 9 Keep power cord away from heated surface 10 Always plug this product directly into the wall outlet receptacle Never use with an extension cord ora power outlet strip that can be relocated 11 In the event that the cooling and heating system malfunctions is not operating or if dropped in water or damaged in any manner please contact Chili Technology 12 Turn off or unplug when not in use 13 Do not use outdoors 14 To unplug this cooling and heating system turn controls to off then remove power plug from outlet 15 D
Download Pdf Manuals
Related Search
Related Contents
Manual de instalación y mantenimiento. SHT - 3305 / CW610E matev ファックスでご注文 Manual de instrucciones USeR`S MANUAl - Mylna Sport Sverige warning - Dale Supply Company DTX-10 - Integra Midland LXT360VP3 two-way radio Copyright © All rights reserved.
Failed to retrieve file