Home

PLC Jobs

image

Contents

1. No Function 45 Get acknowledgement area from PLC e eeee0e00ee00 Parameter 1 Area pointer no 1 4 on TD20 OP20 OP5 15 OP7 17 1 8 on OP25 35 OP27 37 TP27 37 Parameter 2 3 47 Transfer LED area directly to OP a eooo ooo Parameter 1 Area pointer no 1 4 on OP15 OP17 OP20 1 8 on OP25 35 OP27 37 Parameter 2 LED assignment 1st word Parameter 3 LED assignment 2nd word In contrast with PLC job no 42 Get LED area from PLC the LED assign ment area is transferred directly with the PLC job in this case resulting in more rapid activation of the LED The specified LED area must not be configured larger than 2 DW 48 Select menu only for configuration with COM TEXT Parameter 1 Menu number in standard menu 1 Message level including configuration with e eee0e0e ProTool e e e e 2 Main menu e e e 3 Alarm messages 0o 0o o_o 12 Print alarm messages 0 0 o_o 4 Event messages 0o 0o o_o 14 Print event messages 0 0 o_o 5 Screens e e e 6 Recipes e e 7 Statistics functions e 18 Alarm message statistics e 19 Event message statistics _e e 8 PU functions e e e 9 Special functions e e e 24 System messages eee 23 Message texts 0o 0o o_o 22 Settings 0 0 o_o 10 Password Parameter 2 Menu item number 0 First menu item 1 20 Other menu items Parameter 3 49 Delete event buffer eeoeeeeeeeeeeee Parameter 1 2 3 50 Delete alarm buffer eeeeee0ee00 B 8 Parameter 1 2 3
2. Communication User s Manual Release 11 97 PLC Jobs No 51 Function Select Screen Parameter 1 Parameter 2 Parameter 3 LB Cursor lock 0 Off 1 On RB Screen number 1 99 Entry number 0 99 0 Cursor is positioned on first available entry Field number 1 8 1 32 on TD20 OP20 OP5 15 OP7 17 1 255 on OP25 35 OP27 37 TP27 37 on TD20 OP20 OPS OP7 on OP15 OP17 1 255 on OP25 35 OP27 37 TP27 37 Output fields are ignored for serial number purposes Note re TD20 OP20 OP5 15 OP7 17 The input fields of an entry are number consecutively 0 Entry number field 1 First input field n Last input field The numbering of the input fields starts from 1 again for each entry 52 Print screen Parameter 1 Parameter 2 3 Screen number 1 99 in Byte format 53 Select recipe Parameter 1 Parameter 2 Parameter 3 LB Cursor lock RB Recipe number Data record number LB Entry number 0 Cursor is positioned on first available entry RB Field number The input fields of an entry are number consecutively 0 Entry number field 1 First input field n Last input field The numbering of the input fields starts from 1 again for each entry Output fields are ignored for serial number purposes 54 Print recipe Parameter 1 Parameter 2 Parameter 3 Recipe number 1 99 Data record number 1 99 Communication User s Ma
3. PLC address TD OP SAP PLC SAP Interface parameters to be set Baud rate Data bits Stop bits Parity OP address SINEC L1 PROFIBUS and PROFIBUS DP only PLC address PROFIBUS only TD OP SAP PROFIBUS only 7 PLC SAP PROFIBUS only eS Den Communication User s Manual Release 11 97 B 5 PLC Jobs No Function 19 Printer parameters eo ccocce Parameter 1 Value for parameter 2 Number of characters per line 0 20 Characters line 1 40 Characters line 2 80 Characters line Number of lines per page 0 60 Lines page 1 61 Lines page 12 72 Lines page Parameter 2 Printer parameters to be set 0 Number of characters per line 1 Number of lines per page Parameter 3 21 Alarm message display mode 0 00000000000 Parameter 1 0 First oldest message 1 Last most recent message Parameter 2 3 22 Set display brightness e Parameter 1 0 9 corresponds to 10 100 intensity Parameter 2 3 Set display contrast eeee Parameter 1 0 15 Parameter 2 3 23 Set password level 0 000000 000o0o Parameter 1 0 9 0 Lowest password level 9 Highest password level Parameter 2 3 24 Password logout 0 000000 00000 Parameter 1 2 3 29 Print production report e0e0ee0e Parameter 1 2 3 31 Print alarm buffer e0e0ee0e B 6 Parameter 1 0 Print chronologically 1 Print grouped Parameter 2 3 Communication User s Manu
4. times e 18 Average acknowledgement time e 19 Delete buffer yes no e Event message statistics 20 Frequency and duration per group e 21 Frequency and duration per message e 22 Total number and duration e 23 Delete buffer yes no e PU functions 25 Status VAR ee0eee 26 Force VAR e e0eeee Special functions 30 Select language brightness contrast eceeee0e0 _ 31 Change operating mode eceeee0e _ Settings 35 Set time date oe_ eece0e0e 36 Internal interface 0e0e0e0e0 OPS OP7 V 24 OP15 OP17 IF1 37 Module interface e0e0e0e0 OP5 OP7 TTY OP15 OP17 IF2 38 Printer parameters e0e0e0e0 40 Message type e0ee0e0e0e Message texts 45 Display alarm message texts e0ec0ee0e 46 Display event message texts eo_ ee0e0e0 System messages 50 Output system message buffer oe eee0e0e Passwords 55 Login e0e0e0e0 56 Password entry e0e0e0e0 Parameter 2 3 12 Enable disable message logging eo _ 0000000000 o Parameter 1 0 Off 1 On Parameter 2 3 Communication User s Manual Release 11 97 B 3 PLC Jobs No Function 13 Change Language ecoooooooooo oo Parameter 1 0 Ist language 1 2nd language 2 3rd language Parameter 2 3 14 Set Time BCD format eoeoeeeeeeeeeee Parameter 1 LB RB Hours 0 23 Parameter 2 LB Minutes 0 59
5. 3 0 Off 3 On 4 Set Relay eo eoeeee5e Parameter 1 0 Parameter 2 LB FFy RB FFy Parameter 3 0 Off 3 On 5 Select Directory Parameter 1 1 Directory screens display e0ee0e0e 2 Directory recipes display e e0eeee 4 Directory print screens e0e0e0e0 5 Directory print recipes e 0ee0e0 7 Directory recipes data record transfer e 0ee0e0e Parameter 2 3 7 Print All Screens eece0e0e Parameter 1 2 3 10 Print recipe with all data records e0eee Parameter 1 Recipe number 1 99 Parameter 2 3 11 Select Function Screen The following screens integrated in the firmware can be selected by their fixed object numbers Parameter 1 LB Cursor lock 0 Off 1 On e 0ee0e0 Communication User s Manual Release 11 97 PLC Jobs No Function Alarm message buffer 1 Buffer output eceeee0e0 2 Output number of messages 0eeeeee 3 Overflow warning on off eceeee0e 4 Delete buffer yes no eceeee0e0 Event messages buffer 5 Buffer output eceeee0e 6 Output number of messages eeee 7 Overflow warning on off e e0eeee 8 Delete buffer yes no eceeee0e Alarm message statistics 15 Frequency and duration of fault per group e 16 Frequency and duration of fault per message e 17 Average fault
6. Off 1 On Communication User s Manual Release 11 97 PLC Jobs No Function 74 Simulate keyboard eeceeeeo Parameter 1 LB Keyboard number 1 TD20 system keyboard OP20 internal function keyboard OP5 15 internal function keyboard OP7 17 internal function keyboard 2 OP20 system keyboard OPS5 15 system keyboard OP7 17 system keyboard TD17 system keyboard 3 OP20 external function keyboard 16 keys 4 OP20 external function keyboard 24 keys RB Password level 0 is analyzed 1 is not analyzed Parameter 2 LB First Key Code Parameter 3 A summary of the key codes for the OPs is given in Chapter 2 When performing keyboard simulation by PLC job the transmission time from PLC to OP must be taken into account The acknowledgement of an alarm message from the PLC by keyboard simulation can under certain cir cumstances bring about an undesirable result if the alarm message concerned has already been acknowledged by operator input on the OP annew alarm message or a system message arrives before the PLC job is analyzed 75 Scroll event messages e e Parameter 1 0 Off 1 On Parameter 2 3 Communication User s Manual Release 11 97 B 11 PLC Jobs B 1 PLC Jobs Special Cases Jobs with cursor lock B 12 If any of the jobs 11 51 53 72 or 73 is initiated with a value other than 0 specified for the parameter Cursor lock the
7. PLC Jobs Description Listing Communication User s Manual Release 11 97 This section of the Appendix contains a list of all PLC jobs and their relevant parameters PLC jobs can be used to initiate functions on the TD OP from the PLC pro gram for the purposes of displaying screens setting date and time altering general settings A PLC job consists of 4 data words The first data word contains the job number Data words 2 to 4 are used to transfer up to three parameters depend ing on the function in question The basic structure of a PLC job is shown in Figure B 1 Address Left byte LB Right byte RB 1st word 0 Job no 2nd word Parameter 1 3rd word Parameter 2 4th word Parameter 3 Figure B 1 Structure of a PLC Job All PLC jobs that are possible on the various OPs are listed below along with their parameters The No column shows the PLC job number In general PLC jobs can only be initiated by the PLC when the OP is in online mode B 1 PLC Jobs B 2 RB Function screen number No Function 2 Blank Screen oo _ _ _ececccce Parameter 1 0 Off 1 On Parameter 2 3 3 Print Screen e0 0000000000 o Parameter 1 2 3 4 Activate Port an eooo ooo Parameter 1 Port number 1 4 on OP20 1 8 on OP25 OP27 TP27 1 16 on OP35 OP37 TP37 Parameter 2 LB Keyboard number not applicable in case of TP 1 4 on OP20 1 on OP25 35 OP27 37 RB 0 Parameter
8. RB Seconds 0 59 Parameter 3 15 Set Date BCD format eoeoeeeeeeeeeee Parameter 1 LB RB Day ofweek 1 7 Sunday Saturday Parameter 2 LB Day of month 1 31 RB Month 1 12 Parameter 3 LB Year 16 Internal Interface Parameters OP5 OP7 V 24 OP15 OP17 TD17 IFl eeeeeeee Parameter 1 Value for parameter 2 Baud rate FAP and printer only 0 300 baud 1 600 baud 2 1200 baud 3 2400 baud 4 4800 baud 5 9600 baud 6 19200 baud FAP only Data bits FAP and printer only 0 7 data bits 1 8 data bits Stop bits FAP and printer only 0 1 stop bit 1 2 stop bits Parity FAP and printer only 0 Even 1 Odd 2 None OP address 1 30 only on SINEC L1 Parameter 2 Interface parameters to be set 0 Baud rate 1 Data bits 2 Stop bits 3 Parity 4 OP address SINEC L1 only Parameter 3 Communication User s Manual B 4 Release 11 97 PLC Jobs No 17 Function Module Interface Parameters OP5 OP7 TTY OP15 OP17 IF2 Parameter Parameter 2 Parameter 3 Value for parameter 2 Baud rate FAP only 0 300 baud 1 600 baud 2 1200 baud 3 2400 baud 4 4800 baud 5 9600 baud 6 19200 baud Data bits FAP only 0 7 data bits 1 8 data bits Stop bits FAP only 0 1 stop bit 1 2 stop bits Parity FAP only 0 Even 1 Odd 2 None OP address 1 30 SINEC L1 1 31 PROFIBUS 3 122 PROFIBUS DP 1 126 PROFIBUS only 0 63 PROFIBUS only 0 63 PROFIBUS only
9. al Release 11 97 PLC Jobs No Function 32 Print event buffer ee eeeee Parameter 1 0 Print chronologically 1 Print grouped Parameter 2 3 33 Print alarm message statistics l e Parameter 1 2 3 34 Print event message statistics e Parameter 1 2 3 37 Enable disable overflow warning for event messages eoeeeceeeceeecoce Parameter 1 0 Off 1 On Parameter 2 3 38 Enable disable overflow warning for alarm messages 0 000000 00000 Parameter 1 0 Off 1 On Parameter 2 3 39 Reset event message statistics e Parameter 1 2 3 40 Reset alarm message statistics e Parameter 1 2 3 41 Transfer date time to PLC eeoeeeeceeeoeeeee There should be at least 5 seconds between two jobs or else the OP will be overloaded Parameter 1 2 3 42 Get LED area from PLC ee eooo ooo Parameter 1 Area pointer no on OP15 OP17 OP20 on OP25 35 OP27 37 Parameter 2 3 43 Get event message area from PLC eeoeeeeceeeoeeeee Parameter 1 Area pointer no on TD10 20 OP20 OP5 15 OP7 17 TD17 on OP25 35 OP27 37 TP27 37 Parameter 2 3 44 Get alarm message area from PLC eeeceeeeeecee Parameter 1 Area pointer no Parameter 2 3 Communication User s Manual Release 11 97 on TD20 OP20 OP5 15 OP7 17 on OP25 35 OP27 37 TP27 37 B 7 PLC Jobs
10. nual Release 11 97 3 B 9 PLC Jobs No Function 69 Transfer recipe data record from PLC to OP TT _eeeeeececee Parameter 1 Recipe number 1 99 on OP20 OP5 15 OP7 17 Code word 1 on OP25 35 OP27 37 TP27 37 Parameter 2 Data record number 1 99 on OP20 OP5 15 OP7 17 Code word 2 on OP25 35 OP27 37 TP27 37 Parameter 3 0 1 on OP20 OP5 15 OP7 17 0 Data record is not overwritten 1 Data record is overwritten Code word 3 on OP25 35 OP27 37 TP27 37 70 Transfer recipe data record from OP to PLC 00000000000 Parameter 1 Recipe number 1 99 on OP20 OP5 15 OP7 17 Code word 1 on OP25 35 OP27 37 TP27 37 Parameter 2 Data record number 1 99 on OP20 OP5 15 OP7 17 Code word 2 on OP25 35 OP27 37 TP27 37 Parameter 3 on OP20 OP5 15 OP7 17 Code word 3 on OP25 35 OP27 37 TP27 37 71 Partial screen update e0eee0e Parameter 1 0 Off 1 On Parameter 2 3 This job may only be activated when no screen is selected 72 Position cursor on current screen or in current recipe 0 00000000000 Parameter 1 Entry number 0 99 0 600000 Parameter 2 Field number 060 00000000 0o0o 1 8 on TD20 OP20 OP5 OP7 1 32 on OP15 OP17 1 255 on OP25 35 OP27 37 TP27 37 Parameter 3 Cursor lock 0 Off 1 On eeee 73 Position cursor on current function screen ee0eee B 10 Parameter 1 Parameter 2 Parameter 3 Field number 0 8 Cursor lock 0
11. selected input field can not be exited using the arrow keys or the ESC key The cursor lock is not cancelled until e the job is repeated specifying cursor lock 0 e another job that changes the display is executed If an attempt is made to exit the input field while the cursor lock is active the system message 400 Illegal input is displayed The cursor lock is not possible on the graphic display units Communication User s Manual Release 11 97