1. 401 Air Flow Calculation When secondary display in the flow mode CMM CFM the device will calculate flow by the users key in area volume Setting Area Press and hold amp key into the setting mode Press and Okey to select setting area mode as shown in figures Press SSkey into the setting area mode From left to right to set the digits and presse and key to adjust digits to left or right Press and Okey to increase and decrease volume through last right digits Users can press and hold Skey to change area units m ft EN 15 TENMARS TM 401 O The units m maximum volume is 1 5 m3 and minimum volume is 0 096 m D The units f maximum volume is 16 15 ft and minimum volume is 1 03 ft EN 16 TENMARS TM 401 MAX MIN AVG record This function can record maximum minimum and average User can select viewing Press key to start record MAX MIN and AVG Show the max reading to display Press key to switch viewing between MAX AVG and MIN Press and hold en to disable this function In the Set Unit change and recall mode can not used this function Freeze Display HOLD Users can press key to freeze display and press key again to release display In the Set Unit change and recall mode can not used this function EN 17 TENMARS TM 401 99 Records Device cans storage air velocity data up to 99 records Press amp key to storage once record data and shown memory location on th
2. 86 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com
3. 99 records EN 1 TENMARS TM 401 W Memory recall function m Backlight function W Absolute Pressure Sensor M Humidity Sensor Functions Cross table Velocity 99 Record Temperat ure EN 2 TENMARS TM 401 EN 3 TENMARS TM 401 Air Velocity Meter Features E EN 4 TENMARS TM 401 HOLD and Recall key ESC and Rec key Max Min and AVG key Select up and Auto shutoff key Enter and Unit change key Select down and Power key backlight and Set Key Display and Backlight Probes input 10 Battery placement OMONODABRW N gt 11 Battery cover 12 Probes Plug 13 Probes hold 14 Probes sensor Temperature Humidity 15 Blades 16 Internal Pressure Sensor TM 404 EN 5 TENMARS TM 401 Display Features aonana 000000 C F F RH f CMMCFM hPainmmHg o 1 Primary display 2 Secondary display 3 Functional symbol display area 4 Lower battery indication 5 Auto shutoff symbol indication 6 Units of Primary display 7 Units of Secondary display EN 6 TENMARS TM 401 Power On Off In the shutoff mode Press key to turn on he power If want to turn off Press and hold A 7 key L In the Set Unit change and recall mode can not turn off the power Auto Shutoff The device will auto shutoff if there is no action for 15 minutes If want to disable or enable the auto power off function please press and hold key Oln the Se
4. TENMARS Air Velocity Meter TM 401 402 403 404 User Manual CE Oct 2009 Rev 0 1 HB2TM4010000 2009 TENMARS Corporation All rights reserved Table of Contents Ir E 1 Eur 1 Fufetions Cross t ble 2 suessinstvatissspasastvesineissaasus ses entrer HEWAE 311206 2 Ait Velocity Meter Features uie eter ener dek ak te eua 4 Display EE 6 Power OM Otelo cial va too aye ti 7 U E 7 EED Backlight 5 2 2 52 8 Auto Backlight On Off sss 9 Air Velocity Measures nn 11 Change Secondary Display Mode 13 Change US eege 13 Air Flow Calculation s eee tes 15 RIJUMDA NIC 15 MAX MIN AVG record 17 Freeze Display HOLD ione rine teet Ke O xere kela des Ee 17 OO REEOTAS HR 18 Clear Memory insistant 19 Memory Recall a aia ne 20 Battery Replacement 21 2 22 SPECIFICATIONS E 23 TENMARS TM 401 Introduction TM 40X series measures air speed temperature and humidity It is ideal for spot measurements at air outlets on account of its 30mm vane In addition to air speed and temperature TM 404 also measures air moisture and absolute pressure In this way air conditions can be reliably checked Features W 30mm 6 plastics blade m Light air response 0 4m s m Air flow calculate function m Max Min Avg and data hold m Auto power off with disable function m Low battery indication E m Low battery indication m Datalogging capacity
5. e LCD about 1 second When the enable HOLD and MAX MIN function the record data still real reading EN 18 TENMARS TM 401 Clear Memory When the memory are full or want to clear memory data please fallow the setup to clear memory Press and hold key into the setting mode as shown in figures Press A and key to select the clear memory mode Press key into the clear memory mode The LCD showed the yes to reconfirm Press key to leave or press key to clear memory and leave clear memory mode EN 19 TENMARS TM 401 G SET Memory Recall Users can recall the memory data to show on the display Press and hold key into the RECALL mode The secondary display showed the memory location and primary display showed the storage EN 20 TENMARS TM 401 velocity data Press amp and key to increase and decrease memory location If want to leave the recall mode please press and hold key to leave this mode EN 21 TENMARS TM 401 Checking the LCD and Software Version In the shutoff mode Press and hold Okey to turn on device and LCD will keep all dark continued Starting device will show the software version about 1 second Battery Replacement Turn off the device and disconnect all test leads WARNING If the symbol 23 appears on the LCD please replace the battery immediatel before replacing the battery Use only the correct type of batteries properly instal
6. led in the case to power the device EN 22 TENMARS TM 401 Specifications Velocity Unit Range Resolution Accuracy 0 4 25 Km hr kph 1 5 90 mph 0955 ot 2 04 Knots kts 08 48 03 2 04 Beaufort 1 10 1 Air Flow Calculation cem Unit 0 9999 09999 1 E EN 23 TENMARS TM 401 Temperature Unit Range Resolution Accuracy ID 20 60 o 10 Humidity Range Resolution Accurac Unit 20 gt 80 5 RH Absolute Pressure Unit Range Resolution Accuracy hPa______ 350 1100 mmHg 263 825 1 5mmHg ling 103 32 EN 24 TENMARS TM 401 Display 42mm W 33mm L Monochrome LCD with backlight Battery 9V NEDA 160401EC 6F22 or JIS 006P Battery Lift Approx continuous used 100 hours Shutoff Rate Power 3uA Operate Maximum Power 25mA Operating temperature and humidity D To A0 below 80 RH Storage temperature and humidity 100 to 600 below 70 Instrument dimensions 130 L 56 W 38 H mm Weight About 160g Probe dimensions 195 L 47 w 30 H mm Cable length 95cm Weight About 100g Accessories User s manual x1 9V battery EN 25 TENMARS TM 401 x1 Probe x1 Bag x1 End of life Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal EN 26 TENMARS ELECTRONICS CO LTD 6F 5
7. t Unit change and recall mode can not change this EN 7 TENMARS TM 401 LED Backlight When press E key to turn on backlight Press key to turn off again The backlight will turn off of after 30 seconds EN 8 TENMARS TM 401 Auto Backlight On Off Users can set on or off the 30 seconds auto off backlight Press and hold key into setting mode Press and Okey to select BLIGHT setting as shown in figures Press key into Backlight setting Press and key to select auto off on or off Press key to finish and leave setting mode EN 9 TENMARS TM 401 EN 10 TENMARS TM 401 Air Velocity Measures 1 Please insert probe plug into the device sensor input socket 2 Fallow the arrows to measure velocity As shown in figures ARROWS n Please don not touch the blades by fingers or foreign body to avoid damage to the b ades EN 11 TENMARS TM 401 EN 12 TENMARS TM 401 Change Secondary Display Mode In the normal mode Press A and key to change secondary display mode O In the Humidity mode need to waiting minutes to acquire accuracy humidity reading Change Units Press and hold key into the setting units mode If want to change the secondary display units please press and hold eS key again When in the setting units mode LCD blink the choose unit Press A and A key to change the units and press key to finish and leave setting mode EN 13 TENMARS TM 401 EN 14 TENMARS TM