Home
User Manual Netilities 1.1.0 PROFINET-Analyzer
Contents
1. Eam File Action Interfaces Options Help N Device Model Device Role Vendor DeviceID Last received packet a S N 1150600226 Incomming 12 Packets s Buffer OK L a 5 1 Live List Actions The Live List offers several actions to the user These actions can be accessed via the Action menu or via the buttons on the Toolbar The following actions are available Version 0 0 1 2 29 February 2012 Page 18 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved Netilities V1 0 10 C 2011 PROCENTEC PROGENTELC Netilities User Manual File Interfaces Options Help Live Flash LED on device 4 Modify IP address Modify device name Search for Profinet devices Continuously search for Profinet devices Search for IP devices Continuously search for IP devices Remove selected device from list fod Netilities V1 0 10 C 2011 PROCENTEC File Action Interfaces Options Help Live List Statistics SNMP SZ Ae te x mf Mar Address al Protocols Action Flash LED on device Modify IP address Modify device name Search for Profinet devices Continuously search for Profinet devices Search for IP devices Continuously search for IP devices Remove selected device from list Set to factory defaults 5 2 Live List columns The Live List shows a number of columns Description
2. 51 NIST pipe p E 52 Djs X 53 Version 0 0 1 2 29 February 2012 Page 5 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 1 Product description 1 1 Introduction Netilities is a compact and efficient tool to support the user with his PROFINET engineering and troubleshooting tasks It can generate a live list of the PROFINET Ethernet network and spot the devices which are in Data Exchange Statistics provide an overview of the network condition It utilizes the standard Ethernet WLAN port on the PC or interfaces with a ProfiTap Info fields are displayed to inform the user on actual network problems like device missing double device names double IP addresses etc The Statistics provide an overview over the cycle times corrupted telegrams data size etc Netilities is also used to set Device Names and IP addresses and export the detected devices to CSV The LED test feature can identify the targeted PROFINET device The best performance of Netilities is achieved when the laptop is directly connected to the mirror port of a switch which is installed directly behind the PLC or other controller The licensing and software storage is handled by a USB dongle The dongle can be used on multiple PCs 1 2 Product features Y Real time scan Live List of the complete network Y Info panel for network problems device missing
3. Netilities Manual v0 0 1 2 docx Version 0 0 1 2 29 February 2012 Page 26 55 PROCENTEC 2011 2012 Copyright all rights reserved PROGENTEG Netilities User Manual 7 3 Topology detection The Topology detection gives an overview of the topology of your network It is however dependent on the information provided by the devices in the network The level of support for topology information is indicated with colours in the topology Green Topology information available Yellow Some topology information available Red No topology information available sss vaoo 2011 PRocENTEC 007 nnn TON enm File Action Interfaces Options Help Live List Statistics SNMP S Station interface info Topology detection Legend E Topology info is available from this device Some topology info is available from this device E No topology info is available from this device S N 1150600226 The presentation of the topology is schematically given in the following figure Version 0 0 1 2 29 February 2012 Page 27 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual The switch in the figure is a PROFINET switch and provides Netilities with Topology information Netilities is therefore able to determine which device is connected to which port of the switch A switch can normally only hav
4. TECHNOLOGIES Packet Capturing and Network Analysis Solutions Click Next to proceed Version 0 0 1 2 29 February 2012 Page 8 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved F2 CJ C E N T E C Netilities User Manual Welcome to the WinPcap 4 1 2 Setup Wizard This Wizard will guide you through the entire WinPcap installation For more information or support please visit the WinPcap home page http www winpcap org Click Next to proceed You have to accept the terms of the license agreement iPcap License Agreement In cap Please review the license terms before installing WinPcap 4 1 2 Press Page Down to see the rest of the agreement Portions Copyright 1989 by Carnegie Mellon Permission to use copy modify and distribute this program for any purpose and without fee is hereby granted provided that this copyright and permission notice appear on all copies and supporting documentation the name of Carnegie Mellon not be used in advertising or publicity pertaining to distribution of the program without specific prior permission and notice be given in supporting documentation that copying and distribution is by permission of Carnegie Mellon and Stanford University Carnegie Mellon imakes no representations about the suitability of this software for any purpose Itis provided as is without express or implied warranty If you acce
5. Netilities User Manual e Green Topology information is available from the device e Yellow Some topology information is available from the device e Red No topology information is available from the device 4M Netilities V1 0 10 C 2011 PROCENTEC al rlesmActioniminterfaces Options en Help Live List Statistics SNMP N Legend E Topology info is available from this device LL Some topology info is available from this device E wo topology info is available from this device S N 1150600226 4 Version 0 0 1 2 29 February 2012 Page 17 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCENTEG Netilities User Manual 5 Live List The Live List is a table which continuously lists all the available devices It is directly visible which devices are active in data exchange and which devices are inactive With different background colours the status of the devices is displayed e Yellow inactive device This is because the device is not sending any messages The problem could be that a device has been lost or a device has not yet been in data exchange e Light blue Generally active device A device is sending messages but it is not in data exchange with a PNIO Controller e Green Device in data exchange A device is active and it is in data exchange with a PNIO Controller r 48 Netilities V1 0 10 C 2011 PROCENTEC
6. 24 7 SNMP e 25 T3 SNMP ACHONS aonar e AEE TAE EEE NNI EE EANET 25 T2 Station mnterace TAO ooo tenes etaed daiedeivdantd E AEE EEEE AAN 25 La Topology Getection icc stactec 27 8 Processing a PCAP filesi eaaa aaaea aa aaa SA E r aa eaaa EEan EE Eaa ERE EES EE KEARE 29 9 P COMM OU FATON oe seco coe mms 31 10 Using PronTapurssnnrisinre ceseeccettentced eeeeccceteeeceedeececccesteectceseeecuesteuetberseseeuesseeetecteas 33 TO Set UDua eee eet adie de enn ee ere a ee 33 101 1 Only Profi E 33 Version 0 0 1 2 29 February 2012 Page 4 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG 11 11 1 12 13 14 15 16 18 19 20 21 22 23 Netilities User Manual 10 1 2 ProfiTap PC Laptop connected to a free port on the PROFINET Switch 34 zer E M 35 FUSE SlOPS 35 11 11 Assignment 1 FITSUSIODS iiti eaten edere eA ete ere 35 11 1 2 Assignment 2 Create a network drawing cccccceeeeeeeeeeeeeeeeeceaeeeeaeseeeeeseeeesaeeeeeneeees 35 11 1 3 Assignment 3 Assessment of the connected devices ssseeeess 35 Nenities Live LISt E 36 11 2 1 Assignment 4 Interpretation
7. Flashes a LED on the selected device Which LED starts to blink on the device is dependent on the device Mostly the Link LED s will start blinking Used to modify or clear the IP address of the selected device The IP address can only be changed when the selected device is not in Data Exchange Used to modify or clear the device name of the selected device The device name can only be changed when the selected device is not in Data Exchange Used to search for PROFINET devices in the network only once Used to continuously search for PROFINET devices in the network Used to search for IP devices in the network only once Used to continuously search for IP devices in the network Removes the selected device from the Live List Used for instance to remove devices from the list that are no longer active in the network Resets the device to its factory defaults Note This can be done while devices are in Data Exchange Version 0 0 1 2 29 February 2012 Netilities Manual v0 0 1 2 docx Page 19 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 4 Netilities V1 0 10 C 2011 PROCENTEC Le File Action Interfaces Options Help f ve st statistics snmp Bs Info Mac Address Manufacturer Protocols IP Address Device Name Device Model Device Role Vendor Device ID Last received packet The following table det
8. Local Disk C cx Local Disk D eS DVD RW Drive e Removable Dis do HID Wrapper Netilities Jp WinPcap WEE EMT V EE k 4 items HID Wrapper dll Netilities cfg f Netilities app exe netilities1_1150600226 alf 25 8 2009 16 52 Application extens 3 CFG File 24 10 2011 09 21 14 12 2011 12 00 Application ALF File Type ALF File Size 831 bytes Date modified 14 12 2011 12 00 The USB stick can be used on different PCs Netilities Manual v0 0 1 2 docx Version 0 0 1 2 29 February 2012 Page 12 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGENTEG Netilities User Manual 4 Quick start guide 4 1 Adding Netilities to the installation Attach a network cable to the network port of your laptop PC Connect the other end of the network cable to the mirror port on the PROFINET switch The LED of that port should be ON indicating a working link 4 2 Configuring the PROFINET Switch In order for Netilities to receive network data a free switch port should be configured to mirror a port For best results the port on which the PNIO Controller is attached should be mirrored to the port your computer is connected to s o lt zla r E http 192168 O BS X 3 FL SWITCH MCS 14TX 2FX X UU LF 22 sis E PROCENTEC Webmail E pogoplug Sign In PHOENIX CONTACT E ue ML Ly e FL SWITCH MCS 14T
9. com You can also contact PROCENTEC Customer Support e By phone at 31 0 174 671800 By fax at 31 0 174 671801 By email at support procentec com Version 0 0 1 2 29 February 2012 Page 3 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Contents 1 Product descriptio N sssssiiiin ered ccec nh kannan AKAN ed ew AAEE AAAA ANNARRA ed ARANARAK ARRANA ANARA 6 USB Tairo 0l LONA PEPETA r E T TE 6 1 2 PROGUCHTCALUIES ccreidit a ene diaaa aaaea aA aa aa aaar aaa E aaa aa a aE a aapa Nda 6 AS Appicaion areas TA ueeessssaccsueeleeetvvsnaeceustatls 7 1 4 Detectable faults on PROFINET sssssssseseeeeeee entere s nnne intent enint nnne nns 7 1 5 System requirements sssssssssssssssseeeeeee nennen entente nsns st Ekana daana intres 7 2 Software installation instructions eese eeeeeeeeeeeee nennen nnne nnn nn nana nennen nn nnns 8 2 1 Installation procedure sssssssssseseseeeeneeeeenn aenda EAEn E EEANN AERA ia nennen rennen nnns 8 22 dc 8 2 3 Installing WinPcap Driver ussssseseseeeeennnennnnenn aieea anea ada aiaia aE ia 8 2 4 Setting colour preferences ssssssssssssssssseeee ener snnt en nent ennt en rennen 10 EMEND c I 11 3 III 12 BEM WINTROCUCUION EE
10. double addresses etc v Statistics cycle times corrupted telegrams data size etc Y Setting Device Names and IP numbers v Topology scan based on SNMP and LLDP V PROFINET LED test v Suitable for other Ethernet systems Version 0 0 1 2 29 February 2012 Page 6 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 1 3 Application areas L1 Troubleshooting amp maintenance of PROFINET networks U Commissioning of PROFINET networks L Education 1 4 Detectable faults on PROFINET Y General communication faults v Lost missing device v Wrong device name Y Double device names Y Double IP addresses 1 5 System requirements In order to use Netilities and all sub programs your computer system should include the hardware and software listed below The software has been tested to work on Windows XP and Windows 7 Minimum requirements L Microsoft Windows XP L 600 MHz Intel Pentium III processor or equivalent L 512 MB of RAM L 1024x768 resolution display L 1 free USB 2 0 high speed interface port for AppDong L 1 free USB 2 0 high speed interface port when using ProfiTap L 1 free 100Mbit Ethernet port when connecting directly to a switch L 1 mouse or other pointing device Recommended differences from minimum L Dual core 2 GHz processor or equivalent L 1024MB of RAM L 1280 x 1024 resolution display or better IM
11. profibus ie Internet www profibus ie Netilities Manual v0 0 1 2 docx Version 0 0 1 2 29 February 2012 PROCENTEC 2011 2012 Copyright all rights reserved Page 41 55 ITALY C S M T Gestione S C A R L via Branze n 43 45 25123 BRESCIA Italy Tel 39 030 6595111 Fax 39 030 6595000 Email profibus csmt it Internet profibus csmt it GENOA FIELDBUS COMPETENCE CENTRE Srl Via Greto di Cornigliano 6R 38 16152 Genova Italy Tel 39 010 86 02 580 Fax 39 010 65 63 233 Email procentec gfcc it Internet www gfcc it JAPAN Japanese PROFIBUS Organization West World Building 4F 3 1 6 Higashi Gotanda Shinagawa ku Tokyo 141 0022 Japan Tel Fax 81 3 6450 3739 Email info profibus jp KOREA 2802 U Tower 1029 Youngduk dong Giheung gu Yongin Si Kyunggi do 446 908 Korea Tel 82 31 216 2640 Fax 82 31 216 2644 Email chays hiprotech co kr Internet www profibus co kr NETHERLANDS Ehrbecker Schiefelbusch BV Postbus 128 4940 AC Raamsdonksveer Netherlands Tel 31 0 76 578 2860 Fax 31 0 76 571 9261 Email at eselektro nl Internet www eselektro nl NORWAY AD Elektronikk AS Boks 641 N 1401 SKI Norway Tel 47 64 97 60 60 Fax 47 64 97 60 70 Email kai ade no Internet www ade no POLAND INTEX Sp z 0 0 ul Wincentego Pola 16 44 100 GLIWICE Poland Tel 48 32 230 75 16 Fax 48 32 230 75 17 Email intex intex com pl Internet www intex
12. 0 52 01 Fax 45 70 20 52 02 Email hfj9hh automation dk Internet www hh automation dk FINLAND Hantekno Oy Nuijamiestentie 3 B 1 krs 00400 HELSINKI Finland Tel 358 0 9 530 66 570 Fax 358 0 9 530 66 530 Email hannu aarrelampi hantekno com Internet www hanteknoautomaatio fi FRANCE AGILICOM B timent B 1 rue de la Briaudi re Z A La Ch taigneraie 37510 BALLAN MIRE France Tel 33 247 76 Fax 33 247 37 10 20 95 54 Email jy bois agilicom fr Internet www agilicom fr GERMANY PROCENTEC GmbH Benzstrasse 15 76185 Karlsruhe Germany Tel 49 721 831 663 0 Fax 49 721 831 663 29 Email tkarnau procentec com Internet www procentec de Brandt Data GmbH Friedrich Hayn Str 4 D 24582 Bordesholm Germany Tel 49 0 4322 699657 Fax 49 0 4322 699658 Email hbrandt brandt data de Internet www brandt data de profichip GmbH Einsteinstrasse 6 D 91074 Herzogenaurach Germany Tel 49 9132 744 200 Fax 49 9132 744 204 Email sales profichip com Internet www profichip com INDIA UL ELECTRODEVICES P LTD NIRMAN CLASSIC KATRAJ KONDHWA ROAD KATRAJ PUNE 411046 India Tel 91 202 696 0050 Fax 491 202 696 2079 Email dileep miskin ulepl com Internet www ulepl com IRELAND PROFIBUS Ireland Automation Research Centre University of Limerick National Technology Park Plassey LIMERICK Ireland Tel 353 61 202107 Fax 353 61 202582 Email info
13. 12 3 2 Storage location of the license file ssssssessssseeeeen enne 12 4 CQQUICK Stam i 13 4 1 Adding Netilities to the installation eesseesseeeenenennnn nnne 13 4 2 Configuring the PROFINET Switch ssessssssssssseseseeee enne nnns trenes 13 CEMENTERIO x 13 LT MEE Ur m 14 D HMM CAECUS 15 LE S DSC es aa LOL LLL 15 LU MEE Lm 16 5 Live LIST ooo rtnieiEeAUNLEADLIUeLII LIII IM INI 18 Bull EVE LISEACTIONS EE 18 52 JLiweilstcolulris tet TORRE REX aa RANK EERERATUNS snetecensandanne aaa EAE aa Naaa AA 19 6 6S UC Uo e m 21 6 1 Statistics AGHIOS sgeine ieee anaie iaaea NEEE aE a EA a AAEE Ea Aaaa aaa a 21 6 2 Current Cycle TIME de M X 22 6 3 Minimum Cycle Time e ertet eee ke de aneao aaa daa aa a aaa aaaea uu enda 23 64 Maxim m Cycle Time sacceessscectesbaveed vane scadens asccuued a vu d RA e ER Pea evens REOR EE na aa kaaa 23 6 5 Transfer status error COUNT cies ides secede cacestvieniieds e teen ee EUR sane ELA REEL utu EE EIR X ERR RERNE ea dau tu aun 23 6 6 Alas cete ret RR RE RR ex Exe REN RE RECHN e S aS RR SEC AN Ra xag RE RE A aa TIGRE ANS aa RUNE TRER NEA TRE M RR XD aE 23 6 7 JUERICRILA 24 6 8 Abs l te NAMIC R 24 6 9 Rel tivye TraffiC ME
14. EG Netilities User Manual 21 Next versions Detail the SNMP Topology detection chapter with a drawing of an example installation e e Add a photo of the Netilities appdong USB stick e Add technical data of the Netilities appdong USB stick e Add a section which describes how Netilities is connected to an installation Glossary To be defined Version 0 0 1 2 29 February 2012 Page 52 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 22 Notes Version 0 0 1 2 29 February 2012 Page 53 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Version 0 0 1 2 29 February 2012 Page 54 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Version 0 0 1 2 29 February 2012 Page 55 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved Other PROCENTEC products PROFINET Cable Tester v Suitable for 4 and 8 wire PROFINET and regular Ethernet cables v Suitable for straight and 90 metal or plastic PROFINET plugs v Tests cable shielding v Detects short circuits wire breaks swaps miswiring and split pairs v Large LCD clearly indicates the test results v 150 hours on one 9 V battery Y Operating temper
15. IP address Therefore the matrix can display 254 devices at once When more IP ranges are used a new tab will be added to the statistics matrix Each tab corresponds to a certain address range as indicated by the title of a tab 6 1 Statistics Actions The Statistics offer several actions to the user e Netilities V1 1 0 C 2011 2012 PROCENTEC File Interfaces Opis Help Live Search for Profinet devices N Reset statistics for this station Int Reset this statistic Reset all statistics Version 0 0 1 2 29 February 2012 Page 21 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Netilities V1 0 10 C 2011 pRoceNTES File Action Interfaces Options Help Live List Statistics snmp Ge e A Alarms from device controller Info panel 192 168 0 X hanc de lr I n These actions can be accessed via the Action menu or via the buttons on the Toolbar The following actions are available Action Description Search for Profinet devices Used to search for PROFINET devices in the network only once Reset statistics for this Used to reset all statistics for the selected device station Reset this statistic Used to reset the selected statistic for all devices Reset all statistics Used to reset all statistics for all devices 6 2 Current Cycle Time With PROFINET the cycle times ca
16. Interfaces Options Help N Live List statistics snmp Pm G he ah x Info Mac Address Manufacturer Protocols IP Address Device Name Device Model Device Role Vendor Device ID Last received packet zl S N 1150600226 Incomming 12 Packets s Buffer OK N 4 4 Analyzer Netilities itself is an analyzer to display a Live List and to view statistics A quick overview of this is given in the next sections Version 0 0 1 2 29 February 2012 Page 14 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCENTEG 4 4 1 Live List Colours make it easy Netilities User Manual The Live List is a table which continuously lists all the available devices It is directly visible which devices are active in data exchange and which devices are inactive With different background colours the status of the devices is displayed e Yellow inactive device e Light blue Generally active device e Green Device in data exchange r 48 Netilities V1 0 10 C 2011 PROCENTEC File Action Interfaces Options Help H Statistics snmp E7 thw ah x Info Mac Address Manufacturer IP Address Device Name Device Role Vendor Device ID Lastreceived packet Buffer OK S N 1150600226 Incomming 12 Packets s A en 4 4 2 Statistics Click and go The statis
17. MATIC 7 IM151 3PN 6ES7 151 3AA23 DABO HW V4 0 0 FW V7 0 1 SN S C X4UP74712009 192 168 0 151 192 168 0 200 System uptime 0 days 0 09 13 System name System contact System location Index Description Linkspeed_ Phys addr Link Octets n Discards m Errors in Octets out Errors out 1 Siemens SIMATIC S7 inter 100Mbps OOQE8CADSES0 UP 0 0 0 0 0 2 Siemens SIMATIC S7 Ether i00Mbps QOQE8CADSE91 UP 225979 0 0 165211 0 3 Siemens SIMATIC S7 Ether 100Mbps O00ESCADSES2 UP 39041 0 0 134394 o Auto update statistics S N 1150600226 U SS Its corresponding information is then displayed in the fields on the right side Depending on available information from a device the following information can be displayed Field IP address MAC address System description System up System na System co time me ntact System location Link information Description The IP address of the selected device The MAC address of the selected device A short description of the device The time the device has been up and running The name of the device A name or telephone number of a contact person The location of the device A table displaying information about the link s of the device The following columns are presented Index A sequential number Description Link speed Physical address Link Status of the link UP or DOWN Octets in Discards in Errors in Octets out Errors out
18. NMP information This can be fixed by using a ProfiTap and connecting your PC to a free port on the PROFINET Switch see chapter 8 Using ProfiTap for more information SNMP Topology detection does not show a topology This could be because of one or more switches that have not been assigned an IP address Most probably the PROFINET switch the Netilities PC is attached to Check if a correct and free IP address is configured for each switch in the installation or check if it is a managed switch a PROFINET switch Hardware requirements Which USB version is supported Netilities appdong supports high speed USB 2 0 For the latest FAQ list check out our website Version 0 0 1 2 29 February 2012 Page 40 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 14 Sales offices and distributors HEADQUARTERS PROCENTEC Turfschipper 41 2292 JC WATERINGEN Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info procentec com Internet www procentec com ARGENTINA eFALCOM Alcorta 2411 B1744 Moreno Buenos Aires ARGENTINA Tel 54 237 46 31 151 Fax 54 237 46 31 150 Email enrique modai efalcom com Internet www efalcom com ar AUSTRALIA S Systems Pty Limited 14 Laverick Ave Tomago NSW Australia 2322 Tel 61 2 4964 8548 Fax 61 2 4964 8877 Email fritz woller issystems com au Internet www is
19. PORTANT NOTE The performance also depends on the size of the installation The more devices in the installation the more processing power is needed Version 0 0 1 2 29 February 2012 Page 7 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROGCGENTELC Netilities User Manual 2 Software installation instructions This chapter describes the installation for Netilities and the WinPcap drivers It is assumed that you have a basic knowledge of Windows operating systems All examples and dialogs are based on a US UK based Windows installation and may differ slightly based on upgrades updates and enhancements Please use the screenshots in conjunction with the description in order to press the appropriate buttons and other user interface items 2 1 Installation procedure You can run Netilities directly from the USB stick without having to install it on your PC 2 2 First use When Netilities is run for the first time it checks if the required libraries for WinPcap are installed If these WinPcap libraries are not present the WinPcap installer will be launched 2 3 Installing WinPcap Driver The installation of the WinPcap driver is either started by Netilities when it is launched for the first time or by starting it manually from the USB stick WinPcap 4 1 2 Installer m cap Welcome to the WinPcap 4 1 2 Installation Wizard This product is brought to you by ZP CACE
20. PROCGCENTEG User Manual Netilities 1 1 0 PROFINET Analyzer PROFINET analyzer with powerful statistics Suitable for PROFINET IO RT amp IRT Livelist SNMP Information amp Topology scan Runs on XP Vista and Windows 7 platforms Version 0 1 2 29 February 2012 PROCGCENTEG Copyright 2011 2012 PROCENTEC All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning sign and are marked as follows according to the level of danger D Draws your attention to important information on handling the product a particular part of the documentation or the correct functioning of the product Warranty Warranty is void if you open the Netilities appdong Disclaimer of Liability We have checked the contents of this manual as much as possible Since deviations cannot be precluded entirely we cannot guarantee full agreement However the content in this manual is reviewed regularly and necessary corrections will be included in subsequent editions Suggestions for improvements are welcome P
21. ROCENTEC Tel 31 0 174 671800 Turfschipper 41 Fax 31 0 174 671801 2292 JC WATERINGEN Email info procentec com The Netherlands Web www procentec com Version 0 1 2 29 February 2012 PROGENTEG amp Netilities v1 0 10 C 2011 proci b 5 File Action Interfaces Options Help Netilities User Manual Live List statistics sve S N 1150600226 Incomming 12 Packets s Buffer OK User Manual Netilities 1 1 0 PROFINET Analyzer PROFINET analyzer with powerful statistics Suitable for PROFINET IO RT amp IRT Livelist SNMP Information amp Topology scan Runs on XP Vista and Windows 7 platforms Version 0 0 1 2 29 February 2012 Page 1 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Copyright 2011 2012 PROCENTEC All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning sign and are marked as follows according to the level of danger D Draws your attention to i
22. X 2FX L General Instructions L Device Information a General Configuration I Switch Station Services I Ports Port Table Port Cfg Table Port Statistics Mirroring Port Security 4 Diagnostics Home Port Configuration phoenix mcs Port Mirroring Source Port Destination Port Mirroring Status Enter password last update 9 31 56 16 v 3 2 Disable Enable Apply m 4 3 Starting Netilities After starting up the Netilities software the screen as in referentie Fig 49 gt should appear Version 0 0 1 2 29 February 2012 Page 13 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Netilities V1 0 10 C 2011 PROCENTEC _ Sto File Action Interfaces Options Help N tistics SNMP Im Bsnsx Info Mac Address Manufacturer Protocols IP Address Device Name Device Model Device Role Vendor Device ID Last received packet al No AppDong active Incomming 0 Packets s Buffer OK Click on Interfaces and Enable disable interfaces to start the software r g Enable disable interfaces 200 2 HE 3 Wireless Network Connection Im 168 1 60 255 255 255 a Pere Oa After an interface is enabled the Live List should be visible r 48 Netilities v1 0 10 C 2011 proc _ Erma File Action
23. a device supports information like System Uptime System description MAC address IP address is displayed Nests vono to i ocn REO eec File Action Interfaces Options Help Live List Statistics SNMP Station interface info Topology detection IP Devices EI odds 192 168 0 1 192 192 MAC address System description System uptime System name System contact System location 192 168 0 6 X 00 0E 8C AD 5E 90 Siemens SIMATIC S7 IM151 3PN 6ES7 151 3AA23 0ABO HW V4 0 0 FW V7 0 1 SN S C X4UP74712009 0 days 0 09 13 Auto update statistics 1 Siemens SIMATIC S7 inter 100Mbps OO0ESCADSES0 UP 0 0 0 0 0 2 Siemens SIMATIC S7 Ether 100Mbps OO0ESCADSE91 UP 225979 0 0 165211 0 3 Siemens SIMATIC S7 Ether 100Mbps O00ESCADSES2 UP 39041 0 0 134394 0 S N 1150600226 This information can be updated automatically It depends on the devices if their information can be updated automatically Netilities is also able to detect the topology of the network without shutting down the installation The Topology detection creates a clear network structure that contains the location of the devices The result depends on the information supplied by the devices Netilities Manual v0 0 1 2 docx Version 0 0 1 2 29 February 2012 Page 16 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG
24. age 20 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 6 Statistics The statistics matrix is the most powerful feature of the analyzer This field can really indicate what the condition of an installation is It displays the important information that a user especially a maintenance technician is really interested in The different statistics are detailed in the following sections r 4 Netilities V1 0 10 C 2011 proc i TE File Action Interfaces Options Help Live List Statistics snmp 8 MD alarms from device controller Info panel IMAC address 08 00 06 6B FE 6A 192 168 0 X ls Manufacturer SIEMENS AG Vendorjdevice 1D 002A 030 S N 1150600226 Incomming 16 Packets s Buffer OK The user interface of the Statistics matrix is split into two parts a part providing extra information and a part displaying the actual Statistics matrix The information part Info Panel displays extra information of the selected device in the statistics matrix The information that is displayed depends on what information is available for the selected device The MAC address and IP address are displayed for both PROFINET and IP devices The statistics matrix displays the statistics for each device in a matrix representation The place of a device in the matrix is based on its address namely the last byte of its
25. ails Change when these notifications appear B d Figure 1 Popup in Windows XP Figure 2 Popup in Windows 7 Please make sure the configurator is granted full administrator rights If you cannot grant administrator rights to the configurator due to restrictions on your laptop or PC this function will not work When the configurator is started there will be an icon in your Windows tray n Netilities will communicate with this application to configure your Ethernet interfaces When the configurator has been started a window will pop up like in Figure 3 In this window you can create new and modify existing profiles You can also activate or deactivate them When a profile has been activated the selected Ethernet interface will adapt to the settings of the profile An Active profile has a green circle in front of it an inactive profile has a grey circle in front of it F IP Configuration Profile name Interface IP Address Netmask Gateway Qkusiness network Broadcom NetLink TM Gigabit Ether DHCP Oil and Gas installation Broadcom NetLink TM Gigabit Ether 192 168 100 250 255 255 255 0 192 168 100 1 Packaging installation Broadcom NetLink TM Gigabit Ether 10 0 0 200 255 0 0 0 Wastewater installation Broadcom NetLink TM Gigabit Ether 192 168 2 250 255 255 255 0 192 168 2 1 Add profile Delete profile Deactivate profile Duplicate profile Delete all profiles Modify profile Figure 3 IP Configurator
26. ails the information to be found in these columns Column Info Manufacturer MAC address Protocols IP address Device name Device model Device role Vendor Device ID Last received packet Netilities Manual v0 0 1 2 docx Information The number of a row in the Live List In this column icons are used to indicate the type of device or to warn the user about a problem The following icons are used The device in this row encountered a problem Indicates the device in this row is a network device of the PC on which Netilities is running Clicking on the row shows a message in the bottom area of the Netilities user interface Displays the name of the manufacturer of the device The MAC address of the device Displays the protocols used by the device Commonly used protocols are Pv4 Internet Protocol v4 uses 32 bit addresses Pv6 Internet Protocol v6 uses 128 bit addresses e LLDP Link Layer Discovery Protocol ARP Address Resolution Protocol e PROFINET The IP address in use by the device The configured name of the device The model or type of the device Displays the role of the device The role can be either PNIO Controller or PNIO Device PNIO Multidevice or an PNIO Supervisor Displays both the ID of the vendor and the ID of the device Both ID are displayed in hexadecimal notation Displays the date and time when the last packet was received from the device Version 0 0 1 2 29 February 2012 P
27. amp L Nordic AB Box 252 S 281 23 HASSLEHOLM Sweden Tel 46 451 74 44 00 Fax 46 451 89 833 Email hans maunsbach pol se Internet www pol se profibus SWITZERLAND Berner Fachhochschule Technik und Informatik PROFIBUS Kompetenzzentrum Jilcoweg 1 CH 3400 BURGDORF Switzerland Tel 41 0 34 426 68 32 Fax 41 0 34 426 68 13 Email max felser bfh ch Internet www profitrace ch Endress Hauser Process Solutions Kagenstrasse 2 CH 4153 REINACH BL1 Switzerland Tel 41 0 61 715 73 00 Fax 41 0 61 715 73 01 Email michael ulrich solutions endress com Internet www solutions endress com TAIWAN Full Data Technology 6F No 200 Gangqian Rd Neihu District Taipei City 114 Taiwan Tel 886 2 87519941 9097 Fax 886 2 87519533 Email sales fulldata com tw Internet www fulldata com tw TURKEY Emikon Otomasyon DES Sanayi sitesi 103 sokak B 7 blok No 16 Yukari Dudullu Umraniye Istanbul 34776 Turkey Tel 90 216 420 8347 Fax 90 216 420 8348 Email tolgaturunz emikonotomasyon com Internet www emikonotomasyon com UNITED ARAB EMIRATES Adaptive Technologies LLC Shed No 2 Saeed Al Dafoos Building Al Quoz Dubai United Arab Emirates Tel 971 4 3386606 Fax 971 4 3386607 Email sanu adaptivellc com UNITED KINGDOM Verwer Training amp Consultancy 5 Barclay Road Poynton Stockport Cheshire SK12 1YY United Kingdom Tel 44 0 1625 871199 Email a
28. ature 0 to 50 C Y Just 1 key press to start continuous testing Y It can also test telephone and coax cable www profinetcabletester com Compact PROFIBUS Repeater v Single channel PROFIBUS repeater Y Transparent Y Increased signal strength v 12 Mbps v Auto baudrate detection Y Redundant power supply Y Digital glitch filtering v No limit in cascading v Integrated switchable termination Y Diagnostic LEDs v DB9 connector for measurements V IP 20 with DIN rail mounting www procentec com profihub b1 en Other PROCENTEC products ProfiHub B5 v 5 Isolated channels Y Transparent Y Increased signal strength Y 31 devices per channel Y 12 Mbps V 1200 m spur line length Y No address required v Integrated switchable termination V LEDs to indicate termination is ON v Screw terminals and DB9 connectors v IP 20 with DIN rail mounting ProfiHub A5 v 5 Isolated channels Y Transparent Y Increased signal strength Y 31 devices per channel V 12 Mbps Y 1200 m spur line length Y No address required v Integrated switchable termination V IP 65 classification www procentec com profihub PROCENTEC Turfschipper 41 2292 JC WATERINGEN The Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info procentec com Web www procentec com
29. can be seen Telegrams can be sent useful to identify all Profinet devices amp controllers e g DCP functionality A connection must be broken to insert the ProfiTap cabling SNMP information can be retrieved Connect ProfiTap to the USB port Start Netilities and enable both Ethernet interfaces Connect the Ethernet cables Preferred location The ProfiTap on the PNIO Controller port and the PC on a free port of the switch Version 0 0 1 2 29 February 2012 Page 34 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 11 Tutorial This chapter contains some exercises to enhance the practical knowledge of Netilities In order to do these exercises U it is required to connect Netilities the PC it runs on to a working installation with a PNIO Controller that has at least two PNIO Devices in Data Exchange L To have a tool with which configurations can made modified and uploaded to the PNIO Controller 11 1 First steps 11 1 1 Assignment 1 First steps LJ Insert the Netilities dongle in your PC LJ if Netilities is run for the first time on the PC or the PC does not have Wireshark installed install the WinPcap driver supplied with Netilities LJ Start Netilities from the dongle L Go to menu Interfaces gt Enable disable interfaces L Select the interface that is connected to the PROFINET installation When the s
30. check if your installation is running according to your configuration Open the Netilities Statistics When no devices are listed click on the Search for Profinet devices button Select Current cycle time inputs outputs ms as the statistic Investigate the statistics for each device and check whether or not the cycle times correspond with your configuration Assignment 9 Alarms Reset all the statistics Select Alarms from device controller as the statistic Investigate the statistics and check they all are 0 0 Generate an alarm event Device lost Pull Plug alarm Plug wrong module and investigate the statistics Fix all faults after this assignment and check it with the Live List Version 0 0 1 2 29 February 2012 Page 37 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 11 4 Netilities SNMP IMPORTANT NOTE SNMP must be supported by all devices and it must be possible to retrieve a MAC list and or LLDP information 11 4 1 D OOO 11 4 2 Assignment 10 Station interface info Investigate the Live List and check if your installation is running according to your configuration Open the Netilities SNMP Start detection Check if the results of the detection in the Station Interface info correspond with your network drawing Check the system uptime of your PNIO Controller Assignment 11 Topol
31. ckets bypassing the protocol stack and has additional useful features including kernel level packet filtering a network statistics engine and support for remote packet capture Wireless LAN eXtensible Markup Language Version 0 0 1 2 29 February 2012 Page 46 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 18 About PROCENTEC PROCENTEC is an independent company concentrating all its products and services on PROFIBUS and PROFINET technology Our main business is the export of in house developed automation products through our worldwide distributor network PROCENTEC is also providing vendor independent training and support to end users We are an international PROFIBUS and PROFINET Competence Training Center with all the required expertise available to realize our projects and services We have the availability of some real experts whose knowledge makes us unique in the world Because of our international recognition we are often contracted and offer a wide range of commercial services consultancy training commissioning maintenance and troubleshooting PROCENTEC has 2 offices the headquarters is based in The Netherlands and a sales office is located in Germany Testlab PROCENTEC runs 1 of the 8 accredited test laboratories for the certification of PROFIBUS devices In our laboratory vendors can have their products tested on PROFIBUS compatibility Produ
32. cle time that has been measured for the inputs and outputs of the device It is continuously measured and updated when a shorter cycle time has been found 6 4 Maximum Cycle Time This statistic shows the longest cycle time that has been measured for the inputs and outputs of the device It is continuously measured and updated when a longer cycle time has been found 6 5 Transfer status error count This statistic shows how many input and output messages have had a CRC error and have been marked by a switch as faulty The last byte of the PROFINET specific data part on an RT and IRT Data Exchange message contains the Transfer Status IMPORTANT NOTE only PROFINET switches cut through will forward faulty messages 6 6 Alarms This statistic shows the alarms from a device to the controller and from the controller to the device The alarms can have a low and a high priority This statistic does not distinguish between the priorities and counts all alarms and also counts the acknowledge of an alarm An alarm for instance can be Device lost controller to device Pull alarm device to controller Plug alarm device to controller e Plug wrong module alarm device to controller Diagnosis generally from device to controller An extensive list of alarms can be found in the PROFINET Standard Version 0 0 1 2 29 February 2012 Page 23 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserve
33. com pl Netilities Manual v0 0 1 2 docx PROCGCENTEG ROMANIA S C SVT Electronics S R L Braila 7 540331 Tg Mure Romania Tel 40 365 809 305 Fax 40 365 809 305 Email sajgo tibor svt ro Internet www svt ro SAUDI ARABIA asm establishment Al Zahra Dist Attas st cross section with helmy Kutby St Villa no 25 Jeddah 21553 Saudi Arabia Tel 966 2 691 2741 Fax 966 2 682 8943 Email info asmestablishment com Internet www asmestablishment com SINGAPORE SOUTH EAST ASIA ISEP S Pte Ltd Blk 3015A 07 12 Ubi Road 1 Singapore 408705 Tel 65 6356 4237 Fax 65 6844 4265 Email chkoo ise p com Internet www ise p com SLOVAKIA ControlSystem s r o St rova 4 977 01 Brezno Slovakia Tel 421 486115900 Fax 421 486111891 Email jan snopko controlsystem sk Internet www controlsystem sk SOUTH AFRICA IDX ONLINE CC 1 Weaver Street Fourways JOHANNESBURG South Africa 2191 Tel 27 11 548 9960 Fax 27 11 465 8890 Email sales idxonline com Internet www idxonline com SPAIN and PORTUGAL LOGITEK S A Ctra de Sant Cugat 63 Esc B Planta 12 Rubi Barcelona 08191 Spain Tel 34 93 588 67 67 Email xavier cardena logitek es Internet www logitek es ER SOFT SA Av Constitucion 4 E 28230 Las Rozas MADRID Spain Tel 34 916 408 408 Fax 34 916 408 409 Email info er soft com Internet www er soft com Netilities User Manual SWEDEN P
34. ct development and export We develop in house PROFIBUS and PROFINET products that are being exported through our worldwide distributor network Especially in the area of maintenance tools we have gained a unique market position Democenter We have a demonstration facility which is used for support training demonstrations engineering and trade fairs It consists of more than 250 devices from more than 40 vendors Training and Education PROCENTEC is very successful with its training program Up to now more than 4000 participants have received a certificate The costs incurred for engineering assembly commissioning and maintenance always play a key role when choosing a fieldbus We train our participants that the implementation of PROFIBUS and PROFINET can help to cut costs in all areas Our practical experience is the key factor PROCENTEC offers different types of PROFIBUS and PROFINET training modules which are organised on a regular basis PROCENTEC is a professional organisation which is involved in PROFIBUS and PROFINET technology 24 hours a day It has the availability of experts who are constantly deployed worldwide Not only is the tried and tested automation technology ideal for the use in both Factory and Process automation but support is also ensured through the products and services of PROCENTEC www procentec com Version 0 0 1 2 29 February 2012 Page 47 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Cop
35. d PROCGCENTEG Netilities User Manual 6 7 PN Data size This statistic shows the size of the PROFINET specific data part of Data Exchange messages for both inputs and outputs 6 8 Absolute Traffic This statistic gives an indication of traffic on the network by showing the number of packets for both PROFINET and non PROFINET traffic 6 9 Relative Traffic This statistic gives an indication of the network usage for both PROFINET and non PROFINET traffic by expressing their share as a percentage of the total traffic Version 0 0 1 2 29 February 2012 Page 24 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 7 SNMP The SNMP functionality of Netilities allows you to retrieve management information from devices in the network The information can for instance be the uptime its MAC or IP address of a device It also enables Netilities to create a topology of the network indicating who is connected to who This part of Netilities does not show any data by default You must start SNMP detection manually in order to see results in Netilities The user interface of SNMP consists of two parts a part providing station information and a part displaying the network topology based on information retrieved through SNMP The following sections detail what you can do with SNMP in Netilities 7 1 SNMP Actions The SNMP offers a single action t
36. e file has been selected you can start processing the file by clicking on the Start button in the dialog Process PCAP file xs PCAP File D Data temp temp pcap cae V Use inter packet delay from file File statistics Number of packets processed 0 Current state of file processor The information provided in File statistics is updated during processing As the packets from the file are processed the Live List and statistics are also updated r 4 Netilities v1 1 0 C 2011 2012 PROCENTEC M 0 aa File N ion Interfaces Options Help w Statistics snme lowe 479 heh x Info Mac Address a Protocols Manufacturer IP Address Device Name Device Model Device Role Vendor Device ID Last received packet zl Process PCAP file LX j PCAP File D Data temp temp pcap fes IV use inter pat ay from file File statistics Number of packets processed 94 Current state of file processor Active x e e J No AppDong active Incoming 16 Packets s Buffer OK l gt Version 0 0 1 2 29 February 2012 Page 29 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROGCENTEG Netilities User Manual Therefore the Live List shows the devices as if the packets came from a live installation When all the packets from the file a
37. e one link on a port However the figure does show a port with two links to device A and device B When this is shown in the topology it means messages from both devices are received through this port of the switch Probably one of these devices also has a built in switch however it does not provide SNMP topology information Device C on the other hand is able to provide some SNMP topology information Therefore Netilities can now distinguish that device D is connected to device C IMPORTANT NOTE SNMP must be supported by all devices and it must be possible to retrieve a MAC list and or LLDP information Version 0 0 1 2 29 February 2012 Page 28 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 8 Processing a PCAP file When a packet analyzer like Wireshark is used you can save the captured packets into a file This is called a PCAP file With Netilities you are able to import and process the packets of a PCAP file The packets are processed in a similar fashion as if they came from a network interface Therefore the action can be found in the Interfaces menu a Netilities V1 1 0 C 2011 2012 PROCENTEC File Action Interfaces Options Help ta Enable disable interfaces IP Configuration G g d 4 Info Ma Process PCAP file The first step in processing a PCAP file is to select the file to process Once th
38. hi Minh City Vietnam Tel 84 8 3547 0976 Fax 84 8 3547 0977 Email hai hoang bavitech com Internet www bavitech com Version 0 0 1 2 29 February 2012 Page 43 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 15 Products and spare parts Component Order code Remarks 39020 USB appdong containing Netilities and license TUTTI Netilities basic 513 00011A ProfiTap USB cable Hookup cable Software and drivers Manual ProfiTap Version 0 0 1 2 29 February 2012 Page 44 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 17 Glossary CRC CSV Data Exchange Cyclic Redundancy Check Comma Separated Values A file format frequently used for exporting information in an easy to understand format The state of a PNIO Device after parameterization and configuration has been completed in which it cyclically exchanges I O data with an IO Controller Normally the PNIO Device stays forever in Data Exchange until the bus communication or device are stopped DIN German Institute for Standardization www din de Electromagnetic See EMC Compatibility EMC The extent to which an electric or electronic device will tolerate electrical interference from other equipment immunity and wil
39. indow menu Interfaces gt Enable Disable interfaces then click Refresh Version 0 0 1 2 29 February 2012 Page 32 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGENTEG Netilities User Manual 10 Using ProfiTap A characteristic of PROFINET is that in the data exchange telegram there is no distinction possible between controller and device telegrams when only sniffing is done using ProfiTap This makes it impossible to determine certain information Normally the Search for Profinet devices button in Netilities can be used to ask all PROFINET devices to identify themselves and to indicate which functionality they have For this functionality telegrams need to be sent which is not possible if you only have a ProfiTap Therefore it is possible to manually assign functionality to a certain MAC address device For the statistics visualization in combination with a ProfiTap it is necessary to correctly assign the PNIO Controller To do this click on a station in the Live List and then press the right mouse button A popup will appear in which a functionality can be assigned to the device see Figure 5 These functionalities can be assigned to a device L Controller L Device L Multidevice Q Supervisor Netilities V1 0 11 C 2011 PI pS File Action Interfaces Options Help Live List statistics SNMP S47 Awe he x Info Mac Address Protocols Man
40. l The cycle times may differ slightly from one to another This phenomenon is called jitter For PROFINET Jitter is the unwanted variation in the cycle time that could jeopardize real time performance For IRT communication the jitter must be less than 1us for all cycle times For RT communication the jitter must be below 15 of the cycle time Local Area Network The Live List is a matrix that lists all the available devices It is directly visible which devices are active in data exchange and which devices are inactive With different background colours the status of the devices is displayed Media Access Control address a unique identifier assigned to network interfaces for communications on the physical network segment Printed Circuit Board PROFIBUS International The International PROFIBUS Organization based in Karlsruhe PROFIBUS Nutzer Organization The German PROFIBUS Organization based in Karlsruhe ProfiTap Industrial is an interface to perform monitoring on PROFINET networks Simple Network Management Protocol SNMP is an Internet standard protocol for managing devices on IP networks A computer networking device that connects network segments In a communications network the pattern of interconnection between network nodes e g bus ring star configuration WinPcap is the industry standard tool for link layer network access in Windows environments it allows applications to capture and transmit network pa
41. l interfere with other equipment Within the European Community as well as in other countries it is regulated by law that electric and electronic components and equipment comply with basic standards such as IEC 61000 6 2 or IEC 61326 or corresponding individual product standards End Delimiter This byte identifies the end of a PROFIBUS message and has a fixed value of 16 Hex FCS See Frame Check Sequence Frame Check Sequence GSD file GSDML file IRT Netilities Manual v0 0 1 2 docx It is a field in the PROFIBUS message that holds a checksum to check the integrity of the message It is simply the sum of the bytes Checksum DA SA FC DU mod 256 This is simply the bytes added together and divided by FF Hex 255 This is an integrated function that is normally performed by the PROFIBUS ASIC Generic Station Description It is provided by the device manufacturer and contains a description of the PROFIBUS or PROFINET device GSD files provide a way for an open configuration tool to automatically get the device characteristics A GSD file based on XML This is always used for PROFINET Isochronous Real Time Version 0 0 1 2 29 February 2012 Page 45 55 PROCENTEC 2011 2012 Copyright all rights reserved Jitter LAN Live List MAC address PCB PI PNO ProfiTap SNMP Switch Topology WinPcap WLAN XML Netilities Manual v0 0 1 2 docx PROCGCENTEG Netilities User Manua
42. lid for 2 years until December 31 2011 Chairmen of PI Ma J rg Freitag Chairman 25050 JWE Michael J Bryant Deputy Chairman Version 0 0 1 2 29 February 2012 Page 49 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCENTEG Netilities User Manual Pi PROFIBUS PROFINET Certificate Authorization as PI Test Laboratory for PROFIBUS PROFIBUS Nutzerorganisation e V accepts PROCENTEC Turfschipper 41 2292 JC Wateringen The Netherlands as authorized PI Test Laboratory for PROFIBUS Slave Devices PA Profile Devices The authorization is based on the assessment dated March 4 2011 and the related assessment report The execution of the tests aimed in the PROFIBUS certification shall be conform to the PROFIBUS Standard and the valid guidelines This authorization is valid until December 31 2012 Official in Charge Board of PROFIBUS Nutzerorganisation e V J Freitag t i K P M sone BJU S Version 0 0 1 2 29 February 2012 Page 50 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 20 Revision History Version 0 0 1 2 The initial version of the Netilities manual Version 0 0 1 2 29 February 2012 Page 51 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENT
43. mportant information on handling the product a particular part of the documentation or the correct functioning of the product Warranty Warranty is void if you open the Netilities appdong Disclaimer of Liability We have checked the contents of this manual as much as possible Since deviations cannot be precluded entirely we cannot guarantee full agreement However the content in this manual is reviewed regularly and necessary corrections will be included in subsequent editions Suggestions for improvements are welcome PROCENTEC Tel 31 0 174 671800 Turfschipper 41 Fax 31 0 174 671801 2292 JC WATERINGEN Email info procentec com The Netherlands Web www procentec com Version 0 0 1 2 29 February 2012 Page 2 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Important Information Purpose of the Manual This user manual provides information how to work with Netilities Recycling and Disposal The parts of the Netilities appdong can be recycled For further information about environment friendly recycling and the procedure for disposing of your old equipment please contact PROCENTEC Turfschipper 41 2292 JC WATERINGEN The Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info procentec com Document Updates You can obtain constantly updated information on PROCENTEC products on the Internet at www procentec
44. n be configured per device This statistic continuously shows and updates the current cycle time for the inputs and outputs of each single device The exact timing of PROFINET messages is difficult to determine because it depends on network load and delays that may be added by switches in the network Therefore Netilities bases its Cycle Time calculation on the Cycle Counter value of PROFINET messages Simplified this means that Netilities calculates the difference of the Cycle Counter between received messages When a message has been missed it means the difference between the Cycle Counters of the last received message and the current message increases In this statistic this is shown in multiples of the configured send cycle for a PNIO Device For instance a PNIO Device is configured with a send cycle of 2ms A message of the PNIO Device goes missing The current Cycle Time will then become 4ms instead of 2ms Cycle 1 Cycle 2 Cycle 3 Cycle 4 2ms 2ms 2ms 2ms 1 2ms 1 2ms 2 4ms 2 2ms 3 2ms 3 2ms 3 2ms 4 2ms gt lt 4 2ms gt lt 4 2ms gt In a configuration the following cycle time values are possible e ims e 2ms Version 0 0 1 2 29 February 2012 Page 22 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual e 4ms e 8ms e 16ms e 32ms e 64ms e 128ms e 256ms e 512ms 6 3 Minimum Cycle Time This statistic shows the shortest cy
45. ndy verwertraining com Internet www verwertraining com Version 0 0 1 2 29 February 2012 Page 42 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Saftronics Limited Pearson Street Leeds LS10 1BQ United Kingdom Tel 44 0 113 245 7170 Fax 444 0 113 236 4010 Email ian robinson saftronics co uk Internet www saftronics co uk iTech Unit 1 Dukes Road Troon Ayrshire KA10 6QR United Kingdom Tel 44 0 1292 311 613 Fax 44 0 1292 311 578 Email sales itech troon co uk Internet www itech troon co uk Hi Port Software Limited The Hub 2 Martin Close Lee on Solent Hampshire PO13 8LG United Kingdom Tel 44 0 8452 90 20 30 Fax 44 0 2392 552880 Email sales hiport co uk Internet www hiport co uk Parkelect LTD 84 Dargan Road Belfast BT3 9JU N Ireland Tel 44 2890 777743 Fax 44 2890 777794 Emaail jgillan parkelect co uk Internet www parkelect co uk UNITED STATES Grid Connect Inc 1630 W Diehl Road Naperville Illinois 60563 USA Tel 1 630 245 1445 Fax 1 630 245 1717 Email sales gridconnect com Internet www gridconnect com URUGUAY ZyTECH Kuolong s r l Cerro Largo 788 Bis 11100 Montevideo Uruguay Tel 598 2 901 3311 Fax 598 2 901 3311 Email javier zytech com uy Internet www zytech com uy VIETNAM Bavitech Corporation 42 Truong Son Street Ward 2 Tan Binh District Ho C
46. o the user E Netilities V1 1 0 C 2011 2012 PROCENTEC File Interfaces Options Help Live Start detection 8 Station interface info Topology detection E F Netilities V1 0 10 C 2011 PROCENTEC File Action Interfaces Options Help Live List Statistics SNMP s Pe 81 pm 1 MEDI 1 This action can be accessed via the Action menu or via the buttons on the Toolbar The following action is available Action Description Start detection Used to start the detection of devices in the network using SNMP 7 2 Station interface info The station interface info shows a list of detected IP devices on the left side of the user interface The right side of the user interface shows the information of the device selected in the list of detected IP devices A device can be selected by clicking on it Version 0 0 1 2 29 February 2012 Page 25 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual r Netilities V1 0 10 C 2011 PROCENTEC O m P u File Action Interfaces Options Help Live List Statistics SNMP 9 Station interface info Topology detection _ P Devices pp address 192 168 0 6 N 192 168 0 1 192 168 0 3 eee TERREN MAC address 00 0E 8C AD 5E 90 192 168 0 5 192 168 0 6 System description Siemens SI
47. of a PNIO Device in your configuration and use CAPITAL LETTERS and upload the new configuration to the IO Controller Investigate the Live List Change the device name of the PNIO Device to match the new configuration but don t use the CAPITAL LETTERS Investigate the Live List don t forget to switch the PNIO Controller OFF ON Is the device name case sensitive or not Change the device name of a PNIO Device to match another PNIO Device and investigate the Live List don t forget to switch the PNIO Controller OFF ON Fix all faults after this assignment Assignment 6 Changing an IP address Change the IP address of a PNIO Device while it is in Data Exchange Does this work Change the IP address of a PNIO Device and investigate the Live List don t forget to switch the PNIO Controller OFF ON Change the IP address of a PNIO Device to match another PNIO Device and investigate the Live List don t forget to switch the PNIO Controller OFF ON Fix all faults after this assignment Assignment 7 Set to factory defaults Change the IP address of a PNIO Device while it is in Data Exchange Does this work Version 0 0 1 2 29 February 2012 Page 36 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 11 3 Netilities Statistics 11 3 1 E E E a 11 3 2 O OOOO Assignment 8 Current cycle time Investigate the Live List and
48. of the Live List colours eene 36 11 2 2 Assignment 5 Changing a device name sse 36 11 2 3 Assignment 6 Changing an IP address sssssssssssseeeeeeeeennn 36 11 2 4 Assignment 7 Set to factory defaults nens 36 Netilities Statistics d E L 37 11 3 1 Assignment 8 Current cycle time sssssssssssseseeeeeeenneeeen enne nenne 37 11 3 2 Assignment 9 Alarms sssssssssssseeeene eene nennen en nnn ener nnn nnns 37 NetilitioS SNMP e D 38 11 4 1 Assignment 10 Station interface info esses 38 11 4 2 Assignment 11 Topology detection seesseeene enne nen 38 Technical data Netilities appdong eeeeeeeeeeeeeeeeeereeeeere nennen nnn 39 HoIK8yS o RE EA Fout Bladwijzer niet gedefinieerd Frequently asked QUCSTIONS ccceecceceseeeceeeeneneeeeneeeeeeeneee seen seen enen nennen nnn nnne annnm nnmnnn nnmnnn nnmnnn nnna 40 Sales offices and distributors eueeesieeiieeeeeeees sees ee enne nennt nnns n nn nn nnn 41 Products and spare parts eeeeeeeeeeeeeeeeeeeee eene nnn nnne nnn nnne nn tn inse nnt n inse se tn inse nnn nn nan 44 GOS SAMY m 45 Ptole ge 47 Certificates eec ient ana ee er on cu ated re E s 48 Bid
49. oftware is running the Live List of the PROFINET installation should be visible L Check the Live List by switching the PLC ON OFF L Close Netilities when this assignment is ready 11 1 2 Assignment 2 Create a network drawing L Create a drawing of the PROFINET network finish it within 15 minutes Remarks Clearly indicate the location of the devices on the ports of the switch es If you want to know which device is on which port just switch OFF a device and look at the LEDs on the switch Register the MAC addresses of the devices 11 1 3 Assignment 3 Assessment of the connected devices LJ Start Netilities and enable the network interface L How many IO Controllers and or PNIO Devices does the installation have L Does the Live List correspond with your drawing Version 0 0 1 2 29 February 2012 Page 35 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 11 2 Netilities Live List 11 2 1 Assignment 4 Interpretation of the Live List colours Fix each fault after a specific step E E 11 2 2 E n n E Oo 11 2 3 D D OLD 11 2 4 Switch a PNIO Device OFF or remove the PROFINET connector and investigate the Live List Fix all faults after this assignment Assignment 5 Changing a device name Change the device name of a PNIO Device while it is in Data Exchange Does this work Change the device name
50. ogy detection Open the Topology detection Expand all nodes Check if the information displayed at the nodes corresponds with your network drawing Version 0 0 1 2 29 February 2012 Page 38 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 12 Technical data Netilities appdong To be defined Version 0 0 1 2 29 February 2012 Page 39 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual 13 Frequently asked questions Why can t Netilities locate any network interfaces This probably is because the WinPCap Driver is not started The easiest way to solve this is to uninstall the WinPCap Driver and to reinstall it again This time making sure the checkbox Start WinPCap upon Windows Startup is checked at the last step before you press Install SNMP SNMP Detecting devices remains at 0 e This could be because of the TCP IP settings of your network interface that is used to connect to the PROFINET switch Check if a correct and free IP address is configured for the interface and it is in the same range as the PROFINET installation An indication for this is the IP range shown in Netilities is set to 0 0 0 0 255 255 255 0 e The mirror port of the switch does not have the capability to send telegrams In this situation Netilities is unable to retrieve S
51. pt the terms of the agreement dick I Agree to continue You must accept the agreement to install WinPcap 4 1 2 Nullsoft Install Syste lt Back T Cancel Click Next to proceed Version 0 0 1 2 29 February 2012 Page 9 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual Installation options Please review the following options before installing WinPcap 4 1 2 Automatically start the WinPcap driver at boot time Select Automatically start the WinPcap driver at boot time Click Install to proceed Completing the WinPcap 4 1 2 Setup Wizard WinPcap 4 1 2 has been installed on your computer Click Finish to dose this wizard Click Finish to close the installer 2 4 Setting colour preferences The colours of both the Live List and the Statistics can easily be adjusted in the Options Settings menu Version 0 0 1 2 29 February 2012 Page 10 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROGCGENTELC Netilities User Manual Interfaces Options Help statistics SNMF Settings 2 nfo Mac ad ress a Manufacturer Protecos Pares Device Name Device Model Devcencle vendor evcem _ lastrecevedpadet No AppDong active Incomming 0 Packets s Buffer OK Click Options followed by Set
52. re processed the file statistics show how many packets have been processed and that the processor is back in its idle state F Netilities V1 10 C 2011 2012 PROCENTEC i File Action Interfaces Options Help f velist statistics snmp Rro han a x Process PCAP file Lx jJ PCAP Fie DetaWempWemppem a V Use inter packet delay from file File statistics Number of packets processed 386 Current state of file processor Ide No AppDongactive Incoming 0 Packets s Buffer OK Version 0 0 1 2 29 February 2012 Page 30 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROGENTEG Netilities User Manual 9 IP Configuration To start the IP configuration go to the menu Interface gt IP Configuration When you start the configurator a popup box will appear like in Figure 1 Windows XP or Figure 2 Windows 7 N Which user account do you want to use to run this program Current user JProtect my computer and data from unauthorized program activity er Account o T his option can prevent computer viruses from harming your i computer or personal data but selecting it might cause the program Er Program name AutolpCfg exe O The following user Publisher Unknown File origin Removable media on this computer V Show det
53. systems com au Tyco Flow Control Pacific 1 Percival Road Smithfield NSW Australia 2164 Tel 61 2 9612 2323 Fax 61 2 9612 2324 Email rkoenig typac com au Internet www profibuscentre com au AUSTRIA Dipl Ing Christoph Gudenus Rotenmuehlgasse 40 5 1120 WIEN Austria Tel 43 1 812 34 20 Fax 43 1 812 31 55 Email office gudenus at Internet www gudenus at BELGIUM Bintz Technics N V Brixtonlaan 23 B 1930 ZAVENTEM Belgium Tel 32 2 720 49 16 Fax 32 2 720 37 50 Email bloemen bintz be Internet www bintz be BRAZIL Westcon Instrument Indl Ltda Rual Alvaro Rodrigues 257 S o Paulo SP Brazil CEP 04582 000 Tel 55 11 5561 7488 Fax 55 11 5093 2592 Email paolo wii com br Internet www wii com br CHILE RP Ingenieria Limitada Tucapel 92 oficina 52 Concepcion Chile Tel 56 0 41 2469350 Fax 56 0 41 2522592 Email rodrigopinto rpingenieria cl Internet www rpingenieria cl CHINA CAMETA Training amp Marketing Department No 1 Jiao Chang Kou Room 407 De Sheng Men Wai BEIJING 100011 China Tel 86 10 82285088 or 62055653 Fax 86 10 62055653 Email info diewen com Internet www diewen com CZECH REPUBLIC FOXON s r o Poln 367 460 01 Liberec 12 Czech Republic Tel 420 484 845 555 Fax 420 484 845 556 Email foxon foxon cz Internet www foxon cz DENMARK HH Automation A S Hovedgaden 451F DK 2640 HEDEHUSENE Denmark Tel 45 70 2
54. tics matrix is the most powerful feature of the analyzer This field can really indicate what the condition of an installation is It displays the important information that a user especially a maintenance technician is really interested in e Current cycle time e Minimum cycle time e Maximum cycle time e Transfer status error count e Alarms device controller e Absolute traffic PROFINET Non PROFINET e Relative traffic PROFINET Non PROFINET Because of this feature the user does not have to inspect messages or do difficult operations to ensure the quality of the installation e Light blue Changed statistic e Yellow Device is not active Version 0 0 1 2 29 February 2012 Netilities Manual v0 0 1 2 docx Page 15 55 PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual CIUUITEILIEE LIE File Action Interfaces Options Help Live List Statistics snmp io 2 8 Info panel No item selected N Packets PN E N 192 168 0 X o ae eee EE oec sm rmm emen en ee eS E 32 17 o lsls 2 2 s 5 0 31 lincomming 12 Packets s Buffer OK S N 1150600226 E If the statistics do 4 4 8 SNMP NOT show deviations the installation is on the 1st degree OK Management made easy The SNMP functionality can detect the devices in the network Depending on what
55. tings to proceed Settings iem ma Global settings Colors Size Timing Live List colors Device in data exchange CJ Modify Generally active device m Modify n Inactive device GJ Modify Selected device Gl Modify Text color 8g Modify Click on Livelist and Colors to set the Live List colours If you want to adjust the Statistics colours click on Statistics 2 5 Updates It is the policy of PROCENTEC to release periodic updates These updates will overwrite your previous version If you want to keep the previous you can make a backup of it on the USB stick Version 0 0 1 2 29 February 2012 Page 11 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCENTEG Netilities User Manual 3 License system 3 1 Introduction For using Netilities you need the appdong USB stick on which Netilities is supplied The appdong also provides your license for Netilities You purchase a license for the following combination e Netilities Live List Statistics SNMP 3 2 Storage location of the license file The license file for Netilities is stored in Netilities directory of the USB stick eo Organize v Share with v Burn New folder z Fr Favorites Name Date modified Type RE Desktop i Downloads i Recent Places RE Desktop J Libraries Documents gj Music ke Pictures B Videos JB oabbenhuis iMi Computer amp
56. ufacturer IP Address Device Name Device Model Device Role Vendor Device ID Last received packet IO Controller 10 Device 10 Multidevice 10 Supervisor S N 1150600226 Incomming 12 Packets s Buffer OK Figure 5 Assigning device roles in the Live List IMPORTANT There are different modes of operation amp situations when doing Ethernet diagnostics for using ProfiTap this is detailed in the next section 10 1 Set up 10 1 1 Only ProfiTap e All telegrams can be seen but no telegrams can be sent e Ifthe startup procedure of the PNIO Controller is not captured the information visible is limited e Aconnection must be broken to insert the ProfiTap cabling Version 0 0 1 2 29 February 2012 Page 33 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG 10 1 2 Netilities User Manual Basically only a list of devices in data exchange can be seen Manually assigning functionality is needed SNMP info can NOT be retrieved Connect ProfiTap to the USB port Start Netilities and select the Ethernet interface Connect the Ethernet cables Preferred location On PNIO Controller port You have to manually assign a MAC address to a functionality Controller Device Multidevice Supervisor in order for the statistics to be visualized correctly ProfiTap PC Laptop connected to a free port on the PROFINET Switch All telegrams
57. user interface When adding a new profile you have to enter a profile name and select which interface should be used for it If you select DHCP the IP Address Netmask and Gateway can be left blank If you don t select DHCP you have to enter an IP address and Netmask The Gateway is optional If you have created one or more profiles and you run Netilities on another laptop or PC the profiles interfaces should be altered to the interfaces on the new system A popup window will appear which allows you to fix the interface of each profile The popup window looks like Figure 4 Version 0 0 1 2 29 February 2012 Page 31 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCGCENTEG Netilities User Manual r Select alternative interface S Profile Oil and Gas installation DHCP Enabled No IP Address 192 168 100 250 Netmask 255 255 255 0 Gateway 192 168 100 1 The interface of this profile is not found on the system Please select an alternative interface to use for this profile Broadcom NetLink TM Gigabit Ethernet Driver X Figure 4 Select interface popup When you close Netilities all active profiles will be disabled and the original settings of your Ethernet interfaces will be restored NOTE When you change the IP address of an interface you have to refresh the interfaces IP addresses in the interfaces w
58. yright all rights reserved PROGCGENTELC Netilities User Manual 19 Certificates ualityMasters Pasi en Management Systems Registrars QualityMasters hereby declares that Procentec WATERINGEN has a management system that meets the requirements of the standard NEN EN ISO 9001 2008 for the scope Providing training courses technical support product development and the exploitation of the test laboratory Date of original approval 10 02 2003 Date of issue 11 08 2010 Valid until 11 04 2013 Certificate number NL 5147 certificate On behalf of Stichting QualityMasters N B The failure to meet the conditions as set forth in the certification agreement or non compliance with the given standard and or guidelines may lead to the suspension or cancellation of the certificate This certificate remains the property of Stichting QualityMasters Daggeldersweg 10 3449 D Woerden Version 0 0 1 2 29 February 2012 Page 48 55 Netilities Manual v0 0 1 2 docx PROCENTEC 2011 2012 Copyright all rights reserved PROCENTEG Netilities User Manual PROFIBUS PROFINET Certificate for a Pl Competence Center PI confirms that PROCENTEC Dennis van Booma Turfschipper 41 2292 JC Wateringen THE NETHERLANDS is a fully accredited Pl Competence Center for PROFIBUS basic PROFIBUS PA This certificate is granted according to the Quality of Services Agreement for PI Competence Centers and is va
Download Pdf Manuals
Related Search
Related Contents
American Standard Selectronic 6057.155 User's Manual Solution-16 Operators Manual Akai ALD2290H 22" HD-Ready Black LCD TV Orieme CH 11 TURBO 連続吐出型油圧コンバータ - アプライドパワージャパン 南北アメリカの花き業界の消費拡大活動【Flower For Kids】 LabMax シリーズ - コヒレント・ジャパン Manuale piezosmart ita Siemens GENERAL INTERFACE FOR NETWORK APPLICATIONS V 4.0 User's Manual Copyright © All rights reserved.