1. TELEDYNE LECROY Everywhereyoulook USB2 GPIB ye esr USB2 GPIB Converter User s Manual 925566 00 Foreword Thank you for purchasing Teledyne LeCroy s USB2 GPIB Converter hereafter referred to as USB2 GPIB or converterr This manual describes notes on use and basic usage of the USB2 GPIB Before using this product please read this manual thoroughly to gain a good understanding of it After reading please keep the manual in a safe place 2015 by Teledyne LeCroy Inc All rights reserved Teledyne LeCroy is a registered trademarks of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their respective holders Information in this publication supersedes all earlier versions Specifications are subject to change without notice 925566 00 March 2015 Table of Contents OVEFVICW oececccccceccstesesesesseseesesesseeseseessseesssssssssssssssussssnsisisssssnesisississsstsassiesssisaneaesieseaieeeeieees 1 Safety INFOMATION ccccccccceessesestessstesesesseseesesessesssseseeseesseessssessssessssesisseesiessetessensseeeees 2 IEMA COs assaia e A E ses at aes cents se ese ee 2 Howto USe 1he WSB2 GPIBiseuc Aidan ca od Aine nade 3 a CONHECO O armen 3 1G eet elit ATOTAG JOR he GPIB sper san A 4 C COMMUNICATION Stat Ssesscencosnsecreennaea 5 d Firmware UPGrade ccccccccssesesestesesesssssesssesseseessseeseseesssesstssestssssiesssieessneseeees 6 SJ ol lt
2. 161 07 110 8 ee re 7 SCL VIC Cierra cei hs elects se arenes eat oui cieteeta eae ET 8 WAITAIUY cssicdencivrd es senesdenre Gis seus tose apcedecewesatenca etea sub genau E A EEEN 8 GOP UITIGS ATION ssepe na S NES 9 Notes Parts of the contents of this manual may be modified without prior notice for improvements in performance and functions Reproduction or reprinting of the contents of this manual without prior permission from Teledyne LeCroy is prohibited If you have questions about this product please contact Teledyne LeCroy at support teledynelecroy com or 1 800 5 LeCroy Overview The USB2 GPIB Converter enables you to remotely control an oscilloscope from a PC using standard GPIB commands The GPIB connector conforms to IEEE488 2 standard Its delimiter setting is LF EOI The USB connector conforms to USB 2 0 For details of the GPIB commands see the Remote Control Manual on the Teledyne LeCroy website Note that the USB2 GPIB does not function as a controller e Minimum firmware version required for this device is 7 3 0 x Safety Information This symbol may appear on the product to alert you to additional A information contained in the operator s manual The corresponding information in this guide is similarly denoted To avoid personal injury or damage to the USB2 GPIB or any equipment connected to it review and comply with the following safety precautions Use only as intended Using the USB2 GPIB
3. and Batteries The converter is subject to disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper disposal and recycling of your Teledyne GaSe LeCroy product please visit teledynelecroy com recycle RESTRICTION OF HAZARDOUS SUBSTANCES RoHS The converter conforms to 2011 65 EU RoHS2 Directive as it is classified as Industrial Monitoring and Control Instrument per Article 3 Paragraph 24 and is exempt from RoHS compliance until 22 July 2017 per Article 4 Paragraph 3 Visit teledynelecroy com support contact for the latest contact information Thank You for Purchasing a USB2 GPIB Converter 474 TELEDYNE LECROY Everywhereyoulook 700 Chestnut Ridge Road Chestnut Ridge NJ 10977 1 800 5 LeCroy teledynelecroy com
4. upgrade the dongle with the latest firmware The dongle firmware upgrade is successful if the red LED is on USB2 GPIB Specifications Item Specifications Notes The source voltage is supplied from the USB port The appearance or parts of the specifications subject to change without prior notice GPIB driver needs to be properly configured to allow HS488 high speed mode including proper definition of the cable length Service If the converter is inoperable send it back to Teledyne LeCroy Contact us for a Return Materials Authorization RMA number and shipping instructions before sending it Refer to the contact information on page 1 of this manual We will repair it without charge as long as it is under warranty When sending back the converter explicitly describe the following RMA number Product name and serial number Description of the trouble Name post phone number of the owner Warranty NOTE THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR USE TELEDYNE LECROY SHALL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER IN CONTRACT OR OTHERWISE THE CUSTOMER IS RESPONSIBLE FOR THE TRANSPORTATION AND INSURANCE CHARGES FOR THE RETURN OF PRODUCTS TO THE SERVICE FACILITY TELEDYNE LECROY WILL RETURN ALL PRODUCTS UNDER WARRANTY WITH TRANSP
5. ECROY Figure 3 Drawing of USB2 GPIB b Firmware Upgrade After initial driver installation or an oscilloscope firmware upgrade it may be necessary to upgrade the dongle firmware on the USB2 GPIB A pop up window will appear to indicate incompatibility and instruct you to remove the device Follow these steps to upgrade the dongle firmware 1 Download USB2 GPIB dongle firmware upgrade from teledynelecroy com Extract this archive to a local folder of the controller computer e g C Temp Before reconnecting the USB2 GPIB device open the Windows Device Manager utility on your computer Go to the Windows Start Menu and choose Control Panel gt System gt Device Manager While pressing the dongle button underneath the case plug the USB2 GPIB dongle into the computer USB port The dongle should show up as AT32UC3A in the Windows Device Manager list of devices Install the Atmel USB DFU driver Right click on AT32UC3A in the Device Manager and choose Update Driver Software If using Windows 7 choose Browse my computer for driver software if using Windows XP choose Install from a list or specific location Advanced Browse to the Atmel_DFU_USB_Driver folder of the extracted download archive The dongle should now show up as AT32UC3A3 under the Atmel USB Devices folder of the Windows Device Manager list of devices Double click the DFU_UpgradeDongleFW bat file in the driver folder which will
6. ORT PREPAID The converter is warranted for normal use and operation within specifications for a period of three years from shipment Teledyne LeCroy will either repair or at our option replace any product returned to one of our authorized service centers within this period However in order to do this we must first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect accident or abnormal conditions or operation Teledyne LeCroy shall not be responsible for any defect damage or failure caused by any of the following a attempted repairs or installations by personnel other than Teledyne LeCroy representatives or b improper connection to incompatible equipment or c for any damage or malfunction caused by the use of non Teledyne LeCroy supplies Furthermore Teledyne LeCroy shall not be obligated to service a product that has been modified or integrated where the modification or integration increases the task duration or difficulty of servicing the converter Spare and replacement parts and repairs all have a 90 day warranty Certifications EMC Compliance EC DECLARATION OF CONFORMITY EMC The converter meets intent of EC Directive 2004 108 EC for Electromagnetic Compatibility Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities EN 61326 1 2013 EN 61326 2 1 2013 EMC requirements fo
7. and or the equipment it is connected to in a manner not specified by the manufacturer s may impair the protection mechanisms Connect and disconnect properly Do not connect or disconnect equipment to the GPIB connector of the USB2 GPIB during data transfer The green LED of the USB2 GPIB stays lit while the communication is in progress Disconnecting equipment during this time may result in data corruption or equipment damage Do not use in wet damp or explosive atmospheres For indoor use only The USB2 GPIB is intended for indoor use and should be operated in a clean dry environment Do not operate with suspected failures Do not use USB2 GPIB if any part is damaged All maintenance should be referred to qualified service personnel Keep product surfaces clean and dry Maintenance USB2 GPIB is a high quality precision converter To maintain accuracy and signal fidelity avoid mechanical shock as well as damage to the cable through excessive bending It is recommended to inspect cables before use to ensure they are in good condition and are properly connected Poor cables and or connection will result in data corruption Refer all maintenance and component replacement to qualified personnel Do not remove external covers in an attempt to clean internal parts Clean the outside of the USB2 GPIB with a soft cloth dampened with either deionized distilled water or isopropyl alcohol Allow the surface to dry completely before retu
8. r electrical equipment for measurement control and laboratory use European Contact Teledyne LeCroy Europe GmbH Im Breitspiel 11c D 69129 Hidelberg Germany Tel 49 6221 82700 AUSTRALIA amp NEW ZEALAND DECLARATION OF CONFORMITY EMC The converter complies with the EMC provision of the Radio Communications Act per the following standards in accordance with requirements imposed by Australian Communication and Media Authority ACMA AS NZS CISPR 11 2011 Radiated and Conducted Emissions Group 1 Class A in accordance with EN 61326 1 and EN 61326 2 1 Australia New Zealand Contacts RS Components Pty Ltd RS Components Ltd Suite 326 The Parade Wes Unit 30 amp 31 Warehouse World Kent Town South Australia 5067 761 Great South Road Penrose Auckland New Zealand Safety Compliance EC DECLARATION OF CONFORMITY LOW VOLTAGE The converter meets intent of EC Directive 2006 95 EC for Product Safety Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements Environmental Compliance END OF LIFE HANDLING The converter is marked with this symbol to indicate that it complies with the applicable European Union requirements to Directives 2002 96 EC and 2006 66 EC on Waste Electrical and Electronic Equipment WEEE
9. rning the converter to service How to Use the USB2 GPIB a Connection As shown in Figure 1 below insert the USB connector into the USB port of the oscilloscope then attach the IEEE 488 GPIB connector to the PC During the first use of the adaptor Windows will install the device driver You may need to restart the oscilloscope for the adaptor to be functional WaveRunner PC USB2 GPIB gAn TELEDYNE d LECROY gt GP IB connector Figure 1 Connection Diagram of GPIB Control b Setting Up the GPIB Set up the GPIB on the measurement screen of the oscilloscope Figure 2 following the steps shown below Touch Utilities in the menu bar and select Utilities Setup from the pull down menu Click the Remote tab in the setup area in the lower part of the screen Select GPIB in the Control From section Select the GpibAddress and set an address by entering a value Utilities Status Remote Hardcopy Aux Output Date Time Options EL ae TCPIP VICP Gpib Address GPIB LXI VXI11 USBTMC TELEDYNE LECROY Figure 2 Remote Control Setup Screen of the WaveRunner 6 Zi c Communication Status The USB2 GPIB is equipped with two LEDs on the GPIB connector side to indicate the communication status The LEDs indicate the following statuses Red READY LED is ON Power to the USB2 GPIB is ON Green ACTIVE LED blinks to indicate GPIB activity USB2 GPIB a TELEDYNE L

Download Pdf Manuals

image

Related Search

Related Contents

Chapter 1 Welcome to RTI Database Integration Service  DE INHALT  Integra® Miltex®  Télécharger - Est Ensemble  Samsung Galaxy CORE Prime 用户手册  Land Pride FM4088 Lawn Mower User Manual  Tax User Manual - Oracle Documentation  Semestre 9 - Ecole Nationale d`Ingénieurs de Tarbes  RK-Wi.232FHSS-25-FCC™ and FCC-Wi.232FHSS  33-970型 取扱説明書 ガス湯沸器 セントラルタイプ ゆうゆう24  